1. Attention 1 turn onthe power andmake sure it won t surpass theelectric current 2 Make sure to fix leakage protection device andthe socket must be connected with earth line 3 Please don t block the water recycle net by any part of your body if that occurs turn off the pumpor power atonce 4 A switch for the supply of the hot cool water must be installed when stop to use this product The water supply switch and the power source switch should be turned off 5 Check the water level if it is 10 20 mm above the spray nozzle before you start the pump or the pump could be damaged 6 Dispose ofthis product according to the locallaw when itis out ofuse 7 Please contact thelocal dealer forhelp if youhave any problem Circuit diagram OJ O Bottom light Ozone Speaker input of CD frequency Antenna Water probe Electric box nput of control panel O O Black L s White N J Air bubble pump Green G Water pump Heater The related connection will not be connected if theunit without bubble pi Do not dispose this product as unsorted municipal waste Collection of such waste separately for special gu treatment is necessary INSTALLATION INSTRUCTION MASSAGE BATHTUB MODEL WS 084 WoOur lest ela ieel Dear user Thank youvery much for purchasing our sanitary ware To enable you to us
2. 2 Fill water Turn onthe cold or hot water switch to fill water into the bathtub Turn the cool or hot water switch to adjust the water filling speed and water temperature Turn the shift switch to use shower head or faucet to fill water Stop to fill water when the water level 1s 10 20mm above the massage nozzle 8 Radio CD Press Ela to open the radio at the same time the symbol appears on the screen Press una CNY between 87 5MHz to 108 0MHz to search the channel and press it again to search different channels Press way to the turn down volume and press Gary to turn up the 3 Bottom light volume The volume will be shown on the screen and the adjustable Press to turn on the bottom lights then the symbol will be shown on range is 0 40 the screen Press again to turn offthe bottom lights Press again toturn offthe radio and turn on the CD At the same time the symbol will appear on the screen Press it again to turn off the 4 Hydraulic massage adoa CD After system startup water in bathtub exceeds the head level then press button to start water pump and meanwhile waterpump symbol f shall be l l 9 Power off displayed on LCD Repress button to stop waterpump function Press to stop all functions Turn the drainage to let out the water turnoff the power source and the water supply
3. e this product safely and effectively please read this installation and operation manual carefully before use Cautions 1 Please ensure that the product installed reliable electric leakage protection device the power plug contains earth line and make sure it is reliable earthing Check the protect system of leakage protection each time before use 2 Before turn on water pump check if the water level over jets 10 to 20 mm or not make sure regular usage of water pump otherwise it will be destroy because of water leakage 3 Do notturn on water pump heat pump or air bubble pump without water 4 People with Hypertension symptom after drink or heart disease are not allowed to use the bathtub Children have abath must under adult s guidance 5 During use please noticed that don t blocked the jets and avoiding the air adjustment valve overflowing Also keep the bathtub clean and don t let it blocked by hair ormess 6 During use please firstly adjust the water temperature or it will be burned 7 The outdoor spa is designed with ergonomic rise and fall changes are quite big so during use pay more attention of being slipped 8 Please shut down the system when not to use Technical paramete 1 Voltage 220V 60Hz 2 Hydraulic pressure 0 1 0 2Mpa Storage capacity 0 41m Storage capacity 90gallon 3 Power ofthe water pump 750W 4 Power ofthe air pump 200W 5 Power ofthe heat pump 1500W 6 Size 1500X 1500X 640mm Remark Auto heat syst
4. em air bubble pump and the bottom water light are the options forthe goods Cleaning and Maintenat 10 The daily maintenance should be cleaned with ordinary detergent and soft cloth Please do not use the detergent which contains acetone or ammonia liquid Ifthere marks or something like glue on the surface of bathtub just polish it with soft cloth dipping with gas If there are scratches on bathtub surface please polish it with 1500 frosted paper dipping with liquid and burnish it with toothpaste It will be shining again after that If there are furring on the surface of bathtub it can be take away by mild acid detergent for example wipe the bathtub with lemon juice or vinegar which be heated Do not wipe the chrome plated spare parts all the time and do not get in touch with chemical detergent etc Otherwise the surface of chrome plated will be destroyed The product should be clean by soft cloth other than coarse cloth To check the water pipe regularly in order to avoid troubles from crack of water pipes or blocked inside If there are something such as hair stuck inside the jets then just to twist out thejets andremove it To clean hydro massage equipment To full fill hot water which is 40 C and pour 2 L detergent start hydro massage function more than 5 minutes then turn offthe massage function and drain out the water Next to full fill cold water and start hydro massage function for 3 minutes then turn off the
5. justment valve i cannot be adjusted 3 jets or nozzles are blocked l l l 3 remove things which are blockingthe jets Parhiiae 1 seal ring is broken 1 chang seal ring S I ZE i 500x 1 500x640mm Water leaks from 2 screws doesn t lock tightly 2 lock thescrews tightly the pipes 3 pipes doesn t seal properly 3 re seal the silicone 4 water pipe isbroken 4 change water pipe S ke tch 1 Re connect the power source andcheck a i the electricity leaking switch button electricity leaking protectiondevice cut offpower doesn t work 2 change anew control panel 2 power buttonis not working ara Lighting is off Coutelpanel 1 Electricity line didn t connect to power source back water net drainage switch drainage level 9 air conditioning 10 control panel 11 shower 1 change a new speaker 12 air bubble jet Radio is off 2 power lineis disconnected 2 reconnect the circuit 1 The bulb is broken 1 change a new bulb oo 1 cold warm water switch 1 voltage isabnormal 1 please use itat the normal situation 2 water switch Jets shower can 2 Switch cannotbe work of voltage 3 t 2 check and change the switch tap not be work 3 control panel cannot be work ae 4 ill 4 T Aiael F kebe blocked 3 maintain and changethe control panel pow water in romagneti E E cee eg ee eee or ee 4 get rid ofmess of thejets 5 massage sprayer 6 I 8 No lighting 2 power lineis disconnected 2 re connect the circuit 3 maintai
6. massage function and drain out the water at last to dry the bathtub with towel Filter should be clean once a week Keep out from combustibles and goods which over 80 C to avoid fire disaster and damage the product The bathtub should be transported carefully Do not lay heavy things on it and do not bump and shaking the tub If the bathtub has not been used fora long time drain out the water of the bathtub and keep it in a dry and ventilate environment Avoid corrosive gas Troubleshooting 1 Electricity leaking protection device cutoff No power or electricity leaking oe E 1 check andreconnect the wiring system power source whenelectricity line isnot well i i 2 check the power source electricit protection device connected n R is activated 2 Power orelectricity circuit have phenomenon circuit and ground line of electricity leaking 1 check the system whether is on 1 turn onthe system Water Jetsare 2 the impeller of water pump doesn trotate 2 check throughand remove the garbage not working 3 water pump is broken which causedby RS ee Pun ne can be removed Shower working without watercoming in 3 install anew water pump Red pipe hot water pipe blue pipe Jheintesitror 1 water pump s suctionhas not enough power 1 check the water pump whetheris cold water pipe a Shower chain hydro massage 2 air adjustment valveis abnormal working normally 2 GN J gt 2 change the airad
7. n orchange control panel 3 control panel is broken 1 speaker is broken 3 control panel is broken 3 maintain orchange control panel 5 Bubble Press W to start the air bubble pump then the symbol will be shown onthe screen The bubble jets spurt out air bubble Press againto screen a oaae turn offthe bubble frequency backward bottom light volume up heater volume down air bubble pump 6 Heater water pump switch Press eao to startthe heater then the symbol will be shown on the radio CD on off screen The heater could keep temperature of waterin the bathtub Press The related buttonshas no effectif the unit it again to turn off the heater ithout bubble system heat pump bott n ae I The remote control iswaterproof and dampproof Remark The massage bathtub has installed water probe If it is 2 The usage of remote control and the function of control panel is basicallythe same oe waterless or the water lower than the top of probe the air bubble pump R tie control P r irea b ara 3 Lay the remote controlwith care and don tthrow it oo E y water pump and heater will not work 1 Start Press Guon button to start the system and LCD with display function At the 7 Ozone same time all functions will standby Press LOK to start ozone disinfection and press it again to turn off 66 22 Repress button to shut down the system the function This function should be used after bath