DTM Library User Manual - CommDTM ET 200iSP
Contents
1. The CommDTMET 200iSP is protected with a software key You need to license the software for unlimited use 30 days demo license Please contact our support to use the CommDTMET 200iSP with a 30 day trial license Thus you obtain a test license key allowing you to use CommDTM ET 200iSP up to 30 days with complete functionality after activation After expiry of the 30 days demo version you will no longer be able to establish an online connection Online connections existing at the time of expiration will be terminated License state The license is generated for the current system only A transfer to another system is not possible You can find the current license state in the About CommDTM ET 200iSP window context menu gt Additional functions gt About CommDTM ET 200iSP Automatic licensing with Endress Hauser frame application If you are using an Endress Hauser frame application CommDTMET 200iSP is automatically licensed and activated and you can skip the following sections License types There are two general license types Licensing on PC Licensing on USB dongle Hardlock Licensing on PC The licensing on PC consists of a runtime license which activates the complete software functionality on a PC Licensing on USB dongle Hardlock Licensing on USB dongle activates the complete software functionality on that PC where the dongle is connected to The license is bound to the USB dongle The dongle can be
2. T FL FieldCare Device Setup Advanced rieidCare pa FieldMate z V Certified Ethernet xEPI 2 A CommDTM ET 200M gv CommDTM DP PA Link ET 200iSP PROFIBUS DP ET 200iSP Figure 1 Example of a PROFIBUS network with several ET 2001SP CommDTM ET 200iSP User Manual 5 Q Chapter 2 About this manual softing 2 About this manual Read this manual before starting For damages due to improper connection implementation or operation Softing refuses any liability according to our existing guarantee obligations a 2 1 Document history Document version Modifications compared to previous version 1 00 none 2 2 Conventions The following conventions are used throughout Softing customer documentation Keys buttons menu items commands and Open Start gt Control Panel gt other elements involving user interaction are Programs set in bold font and menu sequences are separated by an arrow Buttons from the user interface are enclosed Press Start to start the application in brackets and set to bold typeface Coding samples file extracts and screen MaxDlsapAddressSupported 23 output is set in Courier font type Filenames and directories are written in italic Device description files are located in C StarterKit delivery software Device Description files CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Note This symbol
3. is used to call attention to notable information that should be followed during installation use or servicing of this device Hint This symbol is used when providing you with helpful user hints 8b 6 CommDTM ET 200iSP User Manual softing 3 FDT frame applications Chapter 3 FDT frame applications The different FDT frame applications vary in functionality and naming of the individual functions In this User Manual the naming refers to the FieldCare frame application Complete functionality for the frame application is described in the FieldCare online help FL FieldCare Device Setup Advanced Ele Edit View Device Operation DTM Catalog Tools jose 6 eg F _FieldCare FieldCare New ii Create Project gt HART amp HART MultiDrop ES u Profibus PROFIdtm Service Flow Fx4193 291 Network Figure 2 FieldCare CommDTM ET 200iSP User Manual Endress Hauser f People tor Pacen Aniston gt HART amp HART Point to Point Service Readwin Service Level Pressure FXA19 Administrator Administrator A Chapter 3 FDT frame applications 3 1 Context menu softing Right click an entry in the project window of the FDT frame application to open the context menu Its entries are default entries of the FDT frame application Select Additional functions in this window to display the entries to the respective DTM Func
4. PA_ADDR_35 800P ND800PA_ADDR_50 au _ Devi gi ComeDTM ET 2005P se Channel 0 eom E a 0 VEGABAR 64HART VEGABAR 64HART VEGA Grieshaber KG se VEGABAR 64 HART an VEGABAR 64 HART H AP CommDTM ET 200M Channel amp CommDTM ET 200M ge ND Slot 7Channel1 O Y ND9000H SE VEGAPULS 61 HA dp Slot 8Channel1 O 4 VEGAPULS 61 HART Curren t address fo v Accept Refresh gt E4 Change of the address possible Administrator Administrator Figure 5 Change DTM address Proceed as follows 1 Right click CommDTM ET 200iSP in the project window and select the function Additional functions gt Change DTM addresses 2 Click Refresh to start scanning 3 The DTM addresses are then listed in the window Change DTM addresses Corresponding device names DTM vendors and DTM versions can only be displayed if this functionality is supported by the frame applications 4 Mark the respective DTM 5 Select a new address for the field device DTM from the list box Current device address in the lower window part and click Accept In the status bar of the window information is displayed on whether this function has been completed successfully or whether the DTM does not support this functionality Note This function is not supported by all DI Ms You can only change the DTM address directly through the field device DTM in the project 10 CommDTM ET 200iSP User Manual Q softing Chapter 3 FDT frame applica
5. address from the list box Current device address in the lower window part and click Accept Automatically an online connection to the field device is established the address is modified and the field device is disconnected again In the Status bar of the window information is displayed on whether this function has been completed successfully or whether the field device does not support this functionality Note il After changing the device address you need to set the DTM address of the respective device DTM to the identical address CommDTM ET 200iSP User Manual 9 O Chapter 3 FDT frame applications softing Note Not all devices support device address setting through the CommDTMET 2001SP Device addresses for some field devices can only be set directly at the field device Refer to the manual of the respective field device vendor for detailed information 3 1 2 Change DTM address This functionality allows to display and to change the DTM addresses of the field device DTMs This function is only available when being offline Make sure to use an identical address both for the field device and for its respective DIM The DIM address displayed or set is used during connection establishment to the respective field device File Edit View Device Operation DTM Catalog Tools Window Extras Hel CommDTM ET 200iSP Change DTM addresses X ET 200iSP E PROFIBUS Remote 1 0 E X CommDTM DP PA Link a CommDTM ET 200iSP J ND800
6. ction is only available when being online You can only modify the address of field devices if the field devices support this functionality File Edit View Device Operation DTM Catalog Tools Window Extras e Er AR NRS A Be PROFIBUS Remote 1 0 k CommDTM ET 200iSP ND800PA_ADDR_35 dp Channel 0 2 ND800PA_ADDR_50 dj Channel 0 gt RS 2 VEGABAR 64 HART Slot 4Channel 1 0 VEGABAR 64 HART EH AP CommDTM ET 200M lp Channel 0 110 amp CommDTM ET 200M NDS000H bp Slot 7Channel1 0 gt ND9000H SE VEGAPULS 61 HA Slot 8Channel1 O A VEGAPULS 61 HART Channel Slot 4 Channel 1 v Curent device address 0 Accept Refresh Close gt Scanning finished Administrator Administrator Figure 4 Modify device address Proceed as follows 1 Right click CommDTM ET 200iSP in the project window and select the function Establish connection The existing online connection is displayed in the FDT frame application see Help for FDT Frame Application 2 Right click CommDTM ET 200iSP in the project window and select the function Additional functions gt Change device addresses 3 Click Refresh to start scanning for connected field devices The field devices are then listed in the window Change device addresses Corresponding device names DTM vendors and DTM versions can only be displayed if this functionality is supported by the frame applications 4 Mark the respective field device 5 Select a new
7. es 20 O Chapter 1 About the Comm DTM ET 200iSP softing 1 About the CommDTM ET 200iSP The SIMATIC ET 200iSP Remote I O frequently used in process control plants is an essential structural element for the connection of HART devices to PROFIBUS The respective CommDTMET 200iSP can be implemented into all FDT frame applications according to FDT Specification 1 2 Addendum In this role the DTMacts as a device driver enabling DP V1 communication with HART devices at ET 200iSP peripheral devices and their Device DT Ms The CommDTMET 200iSP considerably facilitates configuration parameterization and calibration as well as commissioning diagnosis and maintenance of field devices You can use the CommDTMET 200iSP within one FDT frame application repeatedly and concurrently depending on the available ET 200iSP in the PROFIBUS network To do so load the CommDTMET 200iSP repeatedly into the project window For the PROFIBUS DP V1 communication a respective physical access to the PROFIBUS and a respective CommDTM PROFIBUS DPV1 needs to be available You can use the CommDTM PROFIBUS DP V1 with xEPI 2 hardware The CommDTMET 200iSP is protected with a software key You need to license the software for unlimited use see Licensing CommDTMET 200iSP functionalities can be accessed through the context menu of the used FDT frame application 4 Comm DTM ET 200iSP User Manual O softing Chapter 1 About the CommDTM ET 200iSP PACTware
8. etwork PROFIBUS network access RE CommDTM PROFIBUS DP V1 amp CommDTM PROFIBUS 5 E AP CommDTM DP PA Link Chann 7 Qg CommDTM DP PA Link N CommDTM PROFIBUS DP V1 x CommDTM ET 200iSP Chann 0 Rs CommDTM ET 200iSP Set DTM address for the following DTM Name CommDTMET200SP DTM vendor Sotting Industrial Automation mbH nn DTM version 000g DTM address of the assigned device 111 v Administrator Administrator a Figure 10 Set DTM address 4 Setthe DTM address and then click OK 2 FieldCare Plant Asset Ma File Edit View Device Operation DTM Catalog Tools Window Extras Help SSAB Bie Si ARE Network Qg CommDTM PROFIBUS DP V1 dy amp CommDTM PROFIBUS HH AP CommDTM DP PA Link lp Chann 7 Q CommD TM DP PA Link CommDTM ET 200SP dp Chann 111 CommDTM ET 200SP Figure 11 Added CommDTMET 200iSP 5 5 Add HART device DIM 1 You can connect up to 128 HART field devices to a ET 200iSP Likewise you can integrate up to 128 HART field device DTMs into the project 2 Right click CommDTM ET 200iSP gt Add device CommDTM ET 200iSP User Manual 17 O Chapter 5 Example of a project design softing 3 From the device catalog select the device DTM and click OK The window for selecting the slot and the corresponding channel appears Slot 4 Channel 1 Slot 4 Channel 2 Slot 4 Channel 3 Slot 4 Channel 4 Slot 5 Channel 1 Slot amp Channe
9. g com SONG
10. i ing sl CommDTM ET 200iSP Extended Field Device Access for Plant Asset Management Applications FDT DTM Plant Asset Management Application e g PACTware DTM Library Ethernet X TH LINK f PROFIBUS Diagnostics Repeater PROFIBUS DP HART HART pne fa PROFIBUS PA Version EN 072015 1 00 Copyright 2015 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds to the technical status at the time of printing of it and is passed on with the best of our knowledge The information in these instructions is in no event a basis for warranty claims or contractual agreements concerning the described products and may especially not be deemed as warranty concerning the quality and durability pursuant to Sec 443 German Civil Code We reserve the right to make any alterations or improvements to these instructions without prior notice The actual design of products may deviate from the information contained in the instructions if technical alterations and product improvements so require It may not in part or in its entirety be reproduced copied or transferred into electronic media Softing Industrial Automation GmbH Richard Reitzner Allee 6 85540 Haar Germany Tel 49 89 4 56 56 0 Fax 49 89 4 56 56 488 Internet http industrial softing com Email info automation softing com Support support automation softing com The latest vers
11. ile Save this file and transfer the file to the original PC Select Activate for this PC Click Import license file and import the file Then click Activate license 12 After a successful activation your license is displayed in the field Available licenses on this PC CommDTM ET 200iSP User Manual softing 5 Example of a project design Chapter 5 Example of a project design The CommDTM ET 200iSP allows to access HART field devices HART field devices do not have a PROFIBUS address Every device is operated through one channel of the HART modules of the ET 200M The PROFIBUS communicates acyclically via a MCL2 configuration master For communication with field devices the respective field device DTM needs to be integrated into the project of the FDT frame application Via this integration the field deviceDTM is assigned to the respective HART module channel of the ET 200iSP PACTware FieldCare _ cer FieldMate er VW Certified Ethernet xEPI 2 IMcL2 f SPS 1 m PROFIBUS DP Dea seH PL FieldCare Device Setup Advanced Datei Bearbeiten Ansicht Ger tebedienung DTM ll MCL1 Netzwerk Tag Host PC CommDTM PROFIBUS DP V1 CommDTM ET 2005P 3E CERABAR 3 DELTABAR 3e ITEMP A CommDTM ET 200M gv CommDTM DP PA Link il L E ET 200isP Figure 8 Communication principle to field devices CommDTM ET 200iSP User Manual 15 O Cha
12. ion of this manual is available in the Softing download area at http industrial softing com softing Table of Contents Table of Contents Chapter 1 Chapter 2 2 1 2 2 Chapter 3 3 1 3 1 1 3 1 2 3 1 3 3 1 4 Chapter 4 4 1 4 2 Chapter 5 5 1 5 2 Dc 5 4 9 9 Chapter 6 CommDTM ET 200iSP User Manual About the CommDTM ET 200iSP uuuuu00444Rnnnenn 4 About this manual 200000000000000noonnnnnnnnnnnnnnnnnnnnnnn 0 6 DOCUMEHENISION een 6 BOHVEHIONS ea 6 FDT frame applications u uuuu00anuenanennannnnnnnnnnnnnnnnnnnnn 7 OE ION oera an a R en ae ae 8 Change device addresses ooo cccccesssccccccecesseeectcccccceeeesseeettseceeeeeeeeeeeeaes 9 Change DTM address uuuuunaaaasseennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnn 10 About the CommDTM ET 200iSP u ununeennennnnennnnnnnnnnnnnnnnnnnennnnnn 11 PGD args EEG E E 12 Ea E E EE E E 13 LICONSO YPO gt eere e EEE E E E E ERE 13 ACUvate CENS een ee ea 14 Example of a project design uuu00u000 0nnnnnnnnennnnnn 15 FSS USE Se erregen 16 FDT frame APP ICAO ee rege 16 Add CommDTM PROFIBUS DP V 222u00022222200000222nnnneneneeennnnnn 16 Add CommDTM ET 2001SP cccccsssssscssrssssscnsseesssessnssensvessscssnresnssenes 17 AI HART BEN Ts near 17 Establish and disconnect a device online COMME CEIOM wecesccccccccnceccccccccccncacscececececeaceceaeaececeueaseeseeeeaeneaea
13. l 2 Slot 5 Channel 3 Slot 5 Channel 4 Slot 6 Channel 1 Slot amp Channel 2 Slot amp Channel 3 Slot amp Channel 4 Slot 7 Channel 1 Slot 7 Channel 2 Slot 7 Channel 3 Slot 7 Channel 4 Mm l Figure 12 Select channel 4 Select the slot with the respective channel for the HART field device numeration of slots channels see Siemens documentation for ET 200iSP Click OK EJ FieldCare Plant Asset Ma File Edit View Device Operation DTM Catalog Tools Window Extras Help ao 6 Be Network nh x ll Host PC El CommDTM PROFIBUS DP V1 dp amp CommDTM PROFIBUS eh NO dp Chann 7 g CommDTM DP PA Link dp Chann 111 Qg CommDTM ET 2005P SE VEGABAR 64 HART 2 dp Slot 4 0 el VEGABAR 64 HART Figure 13 Added field device DIM 18 CommDTM ET 200iSP User Manual O softing Chapter 5 Example of a project design 5 Establish an online connection refer to Establish and disconnect an online connection Note You cannot modify the selected slot and the channel number for a HART field device DTM afterwards If you do have to change the slot or channel number remove the DIM from the project via context menu and then reinsert the DIM again CommDTM ET 200iSP User Manual 19 O Chapter 6 Establish and disconnect a device online connection softing 20 Establish and disconnect a device online connection Establish an online connection 1 Estab
14. lish an online connection to the device Right click on an entry in the project window and select the function Establish connection The existing online connection is displayed in the FDT frame application see Help for FDT Frame Application All superordinated components are connected as well Depending on the selected device you can now read out the configuration or write the configuration set in the FDT frame application to the device To do so use the respective function in the context menu Disconnect an online connection 1 To disconnect the online connection right click the desired entry in the project window Select the function Go offline The connection of the selected device is disconnected Existing connections from other devices are maintained Note You need to establish a connection for each field device You can terminate the connection for each single field device The connection is established and terminated via the context menu of the respective field device DTM IF you terminate the connection to the CommDTMET 200iSP or to the CommDTM PROFIBUS DP V1 all online connections to the field devices are terminated automatically CommDTM ET 200iSP User Manual Softing Industrial Automation Gm Richard Reitzner Allee 6 85540 Haar Germany Tel 49 89 4 56 56 0 Fax 49 89 4 56 56 488 Internet http industrial softing com Email info automation softing com Support support automation softin
15. on opens the User Manual in PDF format Adobe Acrobat Reader is required The User Manual is available after installing the DTM library locally on your system fea FieldCare Plant Asset Management PAM DB Device Setup Advanced 1 0 j j x File Edit View Device Operation DTM Catalog Tools Window Extras Help usna NEIERH Ba BBE WHY Yh bk je Eos PC Datei Bearbeiten Anzeige Fenster Hilfe E Qg CommDTM PROFIBUS DP V1 lt 4 0 Qg CommDTM PROFIBUS DP V1 m i z AX CommDTM DP PA Link lt p Channel 0 7 ei DP PA Link eKA Mierkzeuge om mente 2 ND800PA_ADDR_35 dp Channel 0 35 PD ND800PA h ZENDSOOPA ADDR_50 lt lt Channel 0 50 gt ND800PA Et AP CommDTM ET 200SP dp Channel 0 111 amp CommDTM ET 200SP BE VEGABAR 64HART lt i gt Slot 4Channel1 0 4 VEGABAR 64 HART AP CommDTM ET 200M lp Channel 0 110 Qg CommDTM ET 200M P Contents F 1 About this manual P 2 About the CommDTM ET WT CommDTM ET 200iSP ge ND9000H lp Slot 7Channel1 0 gt NDSOOOH i BE VEGAPULS 61 HART lt Slot 8Channel1 O 4 VEGAPULS 61 HART P 3 FDT frame applications Se ra ae EP 4 Licensing eF 5 Example applications Pe Online offline operation Copytgmt 2015 Soling mastriel Astometion Grae lt u m gt 210 x 297 mm lt Administrator Administrator ls Figure User Manual 12 CommDTM ET 200iSP User Manual 4 4 1 O softing Chapter 4 Licensing Licensing
16. pter 5 Example of a project design soins 9 1 5 2 5 3 16 Prerequisites The following software must be installed FDT frame application Softing DTM Library HART field device DTM FDT frame application 1 Start the FDT frame application 2 Open and update the device catalog 3 Create a new project Add CommDTM PROFIBUS DP V1 1 In the project window right click Host PC and select Add device 2 From the device catalog select CommDTM PROFIBUS DP V1 and click OK 3 Configure the CommDTM PROFIBUS DP V1 To do so open the CommDTM PROFIBUS DP V1 context menu and select Configuration You can find more information in the User Manual for CommDTM PROFIBUS DP V1 File Edit View Device Operation DTM Catalog Tools Window Extras He aene 7 es ME te Network Device type DTM Q CommDTM PROFIBUS DP V1 th RS CommDTM PROFIBUS DP V1 __ Administrator Administrator er Figure 9 Added CommDTM PROFIBUS DP V1 CommDTM ET 200iSP User Manual O softing Chapter 5 Example of a project design 5 4 Add CommDTM ET 200iSP 1 In the project window right click CommDTM PROFIBUS DP V1 and select Add device 2 From the device catalog select CommDTMET 200iSP and click OK 3 The window for setting DTM addresses is opened lt t2 gt File Edit View Device Operation DTM Catalog Tools Window Extras Help SHAKEN BERRA BERE CommDTM DP PA Link x CommDTM PROFIBUS DP V1 x EPI 2 N
17. tionalities displayed in gray are not supported or already opened To select these functions an online connection might be required Integration of CommDTMET 200iSP into a project is described in Section Example of a project design Eile Edit View Device Operation DTMCatalog Tools Window Extras Help Q CommDTM PROFIBUS DP V1 4 0 t AP CommDTM DP PA Link lt p Channel 0 7 ii ND800PA_ADDR_35 4 Channel 0 35 50 ND800PA_ADDR_50 4p Channel 0 C baone al N SB CommDTM ET 2AnSE ge VEGABAR Ta Add Device E AP CommDTM ET 2 gt SE NDSOOOH in HE VEGAPULS Delete Device Launch Wizard te Verify network fa Generate device list Device type DTM info nN Connect p Read from device Write to device SHE SN a Bok w Rg CommDTM PROFIBUS DP V1 CommDTM DP PA Link D ND800PA D ND800PA k CommDTM ET 200SP 2 VEGABAR 64 HART R CommDTM ET 200M gt NDS000H u VEGAPULS 61 HART Save DTM data Restore DTM data Change DTM addresses Channel functions Change device addresses Documentation gt About CommDTM ET 200iSP Import Export gt Help Figure 3 Context menu for the CommDTMET 200iSP CommDTM ET 200iSP User Manual Q softing Chapter 3 FDT frame applications 3 1 1 Change device addresses This functionality allows to display and change the device address of the field devices that are connected to lt LINKNAME gt This fun
18. tions 3 1 3 About the CommDTM ET 200iSP This functionality displays information about the installed CommDTMET 200iSP File Edit View Device Operation DTM Catalog Tools Window Extras Help SGSUSB RRM BE BEE MIB F au CommDTM DP PA Link Change device addresses X CommDTM ET 200iSP Change device addresses x CommDTM El ET 20015P i TTT PROFIBUS Remote 1 0 S oft CommDTM ET 200iSP Network nx a g2 gt tC I BE NDSOOPA_ADDR_35 lt 4 D ND800PA ii HE NDSOOPA_ADDR_50 lt T ND800PA EB CommDTM ET 200SP di amp CommDTM ET 200SP r Se VEGABAR 64 HART 1 VEGABAR 64 HART E AP CommDTM ET 200M dp R CommDTM ET 200M u Be i SE ND9000H 1 T ND9000H IE CommDTM i Se VEGAPULS 61 HA lt VEGAPULS 61 HART for SIMATIC ET 200iSP Product CommDTM ET 200iSP Version 5 00 0 10 License Endress Hauser OEM License Licensing procedure Instructions Vendor Softing Industrial Automation GmbH Support info automation softing com http industrial softing com Administrator Administrator e Figure 6 About CommDTM ET 200iSP Proceed as follows to open this window 1 In the project window right click on CommDTM ET 200iSP 2 Select Additional functions gt About CommDTM ET 200iSP Information about CommDTMET 200iSP are displayed CommDTM ET 200iSP User Manual 11 Q Chapter 3 FDT frame applications softins 3 1 4 Help In the context menu select Additional functions gt Help This functi
19. used alternately with different PCs CommDTM ET 200iSP User Manual 13 O Chapter 4 Licensing softing 4 2 14 Activate license Wy Online help The License Manager includes an online help which gives you detailed information about the licensing procedure and helps you to solve possible problems Click in the left part of the License Manager user interface on Help and select the corresponding topic Licensing on PC with internet access 1 Start the License Manager with Start gt All Programs gt Softing gt License Manager gt License Manager V4 Select Activate for this PC Enter the license key in the following format XXXXX XXXXX XXXXX XXXXX into the field License Key Click Activate license After a successful activation your license is displayed in the field Available licenses on this PC Licensing on PC without internet access 1 a N 9 10 11 Start the License Manager on the PC where you want to use the license Select Start gt All Programs gt Softing License Manager gt License Manager V4 Select Activate for this PC Click Export PC IDs Select your PC and click OK in order to save the file Transfer this file to a PC with internet access and License Manager installed in the current version Start the License Manager Switch toGenerate license file for remote PC Enter the license key Click Import PC Id from remote PC Select Generate and export license f