Home
Wall Screen User Manual.cdr
Contents
1. ccce cece ees 23 VII Appendix o nnnnonnnnnnnnnnnnrnnnnrnnrrrnnenrnrrrrrrnrrrrrrnnne 23 1 Malfunction Alarm 2c csc2cvecertec ess eneranceitastoiececdeuets 24 2 Technical Parameters sccetce tiesscctvesdtdenscdtacseepadecs 24 3 Maintenance and Trouble Shooting 065 25 4 Maintenance of Filter c cece cece cece e eee e eae 27 Product Warranty vin cncastarsnessvacie aoe viceewtivavnsadduitapposesns 28 Overview 1 Please read this instruction manual prior to setting up or operating the aquarium 2 Failure to follow any of the Safety Instructions below will result in the voiding of any warranty for the product and will release dealer and our company from all responsibility and liability 3 If you have any questions or require after sales service please contact your distributor or our company 4 Please check the product prior to use our company will not be responsible for the any damage caused during transportation or maintenance cost Important Safety Instructions NEVER TURN ON THE POWER OF THE AQUARIUM BEFORE FILLING THE WATER TO THE DESIGNATED WATER LEVEL Powering the aquarium on without water may lead to the dry burning of the water pumps and the heater which may lead to fire or damage to the aquarium or bodily harm WARNING TO GUARD AGAINST INJURY BASIC PRECAUTIONS MUST BE OBSERVED INCLUDING BUT NOT LIMITED TO THE FOLLOWING NEGLECTING FOLLOWING THIS USER MANUAL MAY RESULT IN SER
2. a ses see ne ee ners cee eee ee ee 1 Important Safety Instructions cece cece e ee ene ence eee eaeeas 1 Wall Mounted Aquarium amp Screen Aquarium Overview 3 Il Accessories for Wall mounted Aquarium 055 A Ill Wall mounted Aquarium Installation Guide 6 IV Screen Aquarium Installation Guide ccc cee 11 1 WASTEINAMION oc seeedeeneerneienaeaeeseuve ENNER 11 2 Instructions for Components Connections 11 V Functions of the Electronic Panel c 0eeeee 12 1 leonand DIS DION tant xdanusitonccatcevnstcceucatseaats iernii 12 2 Programming the Aquarium and LCD Display 12 ZA LCD Unlock LoCk aveite os ceczaccctciescvesebeeseneneer kone 12 2 2 Date Time hag oo soe teen to poenees cedacteneee toedeeneecusneess 13 29 LOMO OM Ol isisisi aeania REEE cae 14 2 4 Alr PUMP aie nsoes ccenatsavenacovateeesocscectees can anee cout anes 15 Be WAIN E E ETT E 16 2 0 PONO eea E NE E 16 2 7 Water Pumps Circulation Filtration Biochemical FUNCION reierssiea knier ENEE Aai 17 2 8 Auto Feeder scsi ccewnadecncnen neues asker tenbashcesocesisedacus 19 2 9 CO2 Supply access ce ateeteane ess ence teases seaceetasace cane 20 2 10 Manual Operation coc sccacsice ar ctenccteesenicarereeeaee 21 2 11 Selection of Automatic Mode and Manual Mode 21 2 12 Calibrating the LCD Touch Screen 0008 22 2 13 Restore to Factory Setting
3. A Press year Icon to adjust the year B Press month Icon to adjust the month C Press date Icon to adjust the day D Press time icon to adjust the hour E Press minute icon to adjust the minute Press once to increase by one unit press longer to increase the numbers faster If you pass the desired unit keep pressing to start over The above date and time settings are automatically saved after setting After the programming of date and time the system will save the setting automatically after 10 seconds 2 3 Lighting Control Function description There are 3 programmable time cycles for the light The default settings when the light will turn on are 9 00AM 11 00AM 14 00PM 17 00PM and 19 00PM 21 00 PM Users can adjust the working period according to your need Operation Instruction A Manual Operation Press lighting icon res when the icon flickers the lighting function starts B Programming Instruction 1 Press SET and 2 press lighting icon B the Pi pz P3 icon will be displayed 3 press P1 to set P1 starting time for the light Press END to set the ending time 4 P2 and P3 are programmed in the same manner as P1 C Touch SET icon to save the setting and exit the light programming screen The light provides illumination for the aquarium and to provide adequate light for the growth of most live plants It is recommended to keep the light under 6 8
4. an alarm when the sound temperature is above 35 C please notice that the ambient temperature is too high 2 Technical Parameters 2 1 Wall aquarium Technical Parameters Wall mount Aquarium Model Number Item Unit Jooo 1250 1380 1680 1980 2280 2580 2880 1480 1780 2080 2380 2680 2980 Meas mm 1000 1250 1380 1680 1980 2280 2580 2880 150 600 150 600 150 600 150 600 150 600 150 600 150 600 150 600 6 2 21 O ate oe A Water ECN 4M Pump W 1 2M 1000L H 18W 1200L H fen wf ana o Feese _v ocrau soma foofv ow y O juiers L z 7e o 10 129 146 163 afefe e Te e e eT eTo pnw e a 4 53 e2 7 2 2 Screen Aquarium Technical Parameters Screen Aquarium Model Number Item Unit FA C FA C FA C FA C FA C FA C 1380 1480 1680 1780 1980 2080 2280 2380 2580 2680 2880 2980 1340 1640 1940 2240 2540 2840 200 700 200 700 200 700 200 700 200 700 200 700 kem til FB FB FB FB FB FB 1380 1680 1980 2280 2580 2880 1400 1700 2000 2300 2600 2900 200 700 200 700 200 700 200 700 200 700 200 700 size mm 1 2L min 2W DC12V 30Ma DC12V 4W 3 Maintenance and Trouble Shooting Algae Growthin O Too much natural M Aquarium and or Water Turbid water in the aquarium Unstable water temperature sunlight in room where aquarium Is located Overf
5. indirect or consequential loss or damage howsoever caused including the replacement of equipment and property any costs of recovering programming or reproducing any program or data stored or used with HIMAT products and any failure to maintain the confidentiality of data stored on the product The foregoing limitation shall not apply to death or personal injury claims HIMAT disclaims any representation that it will be able to r epair any product under this warranty or make a product exchange without risk to or loss of livestock 3 CONSUMER PROTECTION LAWS FOR CONSUMERS WHO ARE COVERED BY CONSUMER PROTECTION LAWS OR REGULATIONS IN THEIR COUNTRY OF PURCHASE OR IF DIFFERENT THEIR COUNTRY OR RESIDENCE THE BENEFITS CONFERRED BY THIS WARRANTY ARE IN ADDITION TO ALL RIGHTS AND REMEDIES CONVEYED BY SUCH CONSUMER PROTECTION LAWS AND REGULATIONS Some countries states and provinces do not allow the exclusion or limitation of incidental or consequential damages or exclusions or limitations on the duration of implied warranties or conditions so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary by country state or province This Limited Warranty is governed by and construed under the laws of the country of production HIMAT the warrantor under this Limited Warranty is identified at the end of this document according to the country or region in w
6. the upper Fix it to the upper left side Aquar ium Light and Hood i vT NTC Temperature sensor Right pump Left pump os CO2 supplier oa Control panel Left filtration box Fuse Switch biochemical system UV Light not included E Right filtration box bioche mical system Figure 2 Main Profile Important The air pump and auto feeder are not water submersible and can not be dipped into the water The water pumps CO2 generator and heater are water submersible and must be operated only underwater in order to avoid dry burning II Accessories for Wall mount Aquarium 1 Mounting Hardware Figure 3 m wd _ fu 1 M10X60mm Anchor screw c4 3 Wrench 6mm te Clips Mounting Bracket Figure 3 Mounting Hardware Included WALL MOUNTED CEMENT ANCHOR SCREWS 6PCS Wall mounted fixing clips 2pcs Steel Mounting Bracket 2pcs Wrench 1pc THE ANCHOR SCREWS INCLUDED WITH THE AQUARIUM ARE SUITABLE FOR CEMENT WALLS ONLY Ifyou are securing to wood or metal studs please use appropriate mounting hardware or consult an expert A Not all aquariums will have accessory screws Screws included will only be suitable for cement wall If the accessory screws are lost or damaged please contact the distributor or the agent B Ifthe aquarium size is over 2180mm or 7 ft 3 mounting brackets 3pcs clips and 9pcs anchor screws are recommended for safe installation C Additional mounting brackets and clips are availab
7. IOUS INJURIES OR DAMAGE TO THIS AQUARIUM IF YOU HAVE ANY QUESTIONS OR REQUIRE REPAIR PLEASE CONTACT YOUR LOCAL AUTHORIZED DEALER OR OUR COMPANY WARNING ANY UNAUTHORIZED REPAIR OR MODIFICATION WILL VOID ANY WARRANTY AND RELEASE THE MANUFACTURER AND DISTRIBU TOR OF ALL LIABILITIES OR ANY DAMAGES CAUSED BY THE PRODUCT MODIFICATION FISH KEEPING OR SIMILAR APPLICATION Never try to modify any parts by any means for this may result in fire damage electric shock or injuries Internal inspection repair and maintenance should be carried out by local distributors or suppliers Never use this product near inflammable gases which will increase the danger of electric shock Please make sure the tank is securely hung onto the brackets before operating Do not turn on or operate the aquarium if the electrical components or power supply has gotten water to avoid short circuit and electric shock For the most secure hanging make sure that the aquarium mounting brackets are safely secured to the wood or cement studs in the wall Always turn off and unplug the aquarium when performing routine maintenance Please follow the operation guide and gradually fill in water from the top of body tank Avoid splashing the water onto the aquarium controller or control panel Never hang or remove the aquarium when full of water It is recommended to fill up the aquarium with water after the aquarium has been safely hung and attached to the
8. TANT The CO2 supplier must work underwater Operating the CO2 above water may cause malfunction Operation Description A Manual Operation Touch Ea icon when the icon flashes the function starts B Programming Instruction 1 Touch SET icon and touch licon while SET icon flashes the P1 P2 and P3icor Fi Fa Pa will appear hla e 2 touch START to set the starting period Carbon dioxide generator will automatically work together with lighting system so if the CO2 turns on the light will automatically turn on with the programmed CO2 cycle in order to promote photosynthesis For best effect please program CO2 to match normal programmed lighting cycle IMPORTANT The CO2 supplier helps the growth of aquarium plants by providing valuable CO2 for photosynthesis It does not replace other nutrients that the aquarium plants will need If you do not plan on keeping live plants the CO2 supplier can be removed If you want to manually turn off the CO2 generator please press END icon while it is operating to stop this function 2 10 Manual Operation The aquarium can be manually controlled so all operations can be started or stopped manually Any function started manually will run for 30 minutes and then return to automatic state Operation Instruction Turn on function Press the unlock icon for 3 seconds the icon flickers with buzzing which means the operation panel have started Press any functio
9. al airi ideg mD CHEN D mode U Light _ Setting Lighting Heater Let pump E Air pump AA 5 Gey E Right pung Lock unlock T n u Feeder F aE ES leg TOZ _ J supplier Figure 9 P E Water Left a ae E UVB UV light Date AUTO alie 3 amp su gra ote P2 Sonic P3 wane MAN sali time time time 2 Programming the Aquarium and LCD Display 2 1 LCD Unlock Lock The control panel will automatically LOCK to its default mode to avoid tampering or the settings being unintentionally changed Any programming requires the LCD Display to be unlocked first Operation Instructions A The control panel automatically locks to prevent tampering Prior to programming the aquarium control panel the control panel must be unlocked B To unlock the control panel touch unlock icon for 3 seconds to unlock the control panel The control panel is unlocked and can be changed when the icon has changed to 6 C All the changes to programming will be effective right away Do not turn off the power supply before the control locks in order to save setting D The automatic function will be temporarily stopped while switching to manual mode 2 2 Date Time Aquarium must always be unlocked in order to program Operation Instructions Press the digital number corresponding to the number that you want to change until you have selected the correct figure For instance
10. aviolet lamp sterilizes the aquarium water and can help to kill the pathogen and algae in the water The default working time is 21 00PM 0O 00AM Operation Description Refer to air pump description CAUTION The UV light should be placed inside the filtration box and kept away from direct exposure to fish and human eyes in order to avoid any injuries 2 6 Heater Function description A The default temperature is 25 C When the thermostat of the heater detects that the water is below the preset temperature the heater will work automatically till the water reaches the preset temperature B While the heater is operating the water pump will work at the same time to cycle the warmed water C If you are keeping tropical fish the recommended temperature setting is between 24C 27 C Ifyou are keeping goldfish the 16 Cee should be adequate Operation Instruction A Press heater icon the icon of temperature digits flickers to change the default setting press SET icon then press heating icon _ When the icon and water temperature flicker touch the temperature to change the parameter then press SET to save the heater temperature setting B Users can adjust the temperature according to the species of fish The adjustable temperature range is from 16 C to 32 IMPORTANT A Heater should only be operated underwater and should never be turned on or powered outside of the water B Hea
11. ckering and beep continuously B Step 2 Calibrate the LCD Screen Keypad Touch the four corners of LCD screen using your finger press the four corners of the LCD screen starting with the upper left corner proceeding clockwise as shown in Figure 10 The screen will flicker with a beep when you touch the correct place in each corner After touching the four corners the system will automatically save the new calibration and restore to the normal display after a few seconds C If the calibration is not successful please repeat the above procedures D If screen calibrate is not required do not touch the screen after you enter the screen calibration mode The system will exit the calibration mode automatically and restore to normal display after 5 seconds Figure 10 The position of four corners of screen calibration 2 13 Restore to Factory Settings After unlocking the screen press SET icon for 5 seconds the control panel will turn off and switch on the control panel after 3 seconds default settings will be restored VII Appendix 1 Malfunction Alarm Reasons of Malfunction Indication Solutions for Malfunction Malfunction Malfunction of water temperature thermostat NTC please check the wiring of the detector or change a new detector Heater is damaged or the water temperature is not reaching the programmed value manually stop the alarm E2Alarm E per5 E1 Alarm E4 with There will be
12. eeding or need to maintain No live plants but CO2 continues to operate Make sure aquarium is not hung in direct sunlight or well lit room with lots of ambient sunlight Clean algae thoro ughly when planting aquatic plants and Reduce the lighting time at the same time Feed the fish only one time per day and only what they can consume in 2 minutes M Add plecostamus Filter sponges need M to be cleaned Filtrating pump is notM operating Heater damaged Aquarium temperature reading is high or other algae eating fish Snails are not recommended as they reproduce too quickly Remove CO2 generator Clean the filter see the structure of the filter Check connection of waterproof connectors Change the component to smaller water pump It is normal for the aquarium temperature to be a few degrees above room temperature Inspect heater to make sure it is No bubbles when O Air pump is not VI Air stone or tubing is the air pump is pumping air or clogged or has kink working pumping very few M The air stone is buried bubbles too deep in water M Shift sand gravel to make sure it is not covered too deep M Replace air pump MV Replace CO2 supplier suggested replacement every 400 hours Carbon dioxide H Carbon rod is not producing depleted bubbles VI Reset control panel to default setting and try again Unable to save Backup battery of settings in co
13. ers suppliers or publishers other than HIMAT may provide their own warranties to the end user purchaser but HIMAT in so far as permitted by law provides their products as is Software distributed by any of our dealer with or without the HIMAT brand name including but not limited to system software is not covered under this Limited Warranty Refer to the licensing agreement accompanying the software for details of your rights with respect to its use HIMAT does not warrant that the operation of the product will be uninterrupted or error free HIMAT is not responsible for damage arising from failure to follow instructions relating to the product s use This warranty does not apply a to damage caused by use with non HIMAT products b to damage caused by accident abuse misuse flood fire earthquake or other external causes c to damage caused by operating the product outside the permitted or intended uses described by HIMAT d to damage caused by service including upgrades and expansions performed by anyone who is not a representative of HIMAT e to a product or part that has been modified to significantly alter functionality or capability without the written permission of HIMAT f to consumable parts such as light bulbs and fuse g if any HIMAT serial number has been removed or defaced h if damage cause by neither installation nor i installing procedure HIMAT is not responsible for installation pr
14. f fish per gallon of water Step 14 Automatic Feeder If you choose to use the automatic feeder please monitor the quantity of food being fed to the fish The feeder can be programmed to feed the fish multiple times in the day In the first week of the automatic feeder please monitor the quantity of food being dropped into the aquarium to avoid overfeeding Note How much to feed Only feed the fish the amount of food they can completely consume in a 3 minute timeframe It is better to underfeed the fish than to overfeed the fish IV Screen Aquarium Installation Guide 1 Installation Step 1 Place the cabinet of the screen aquarium on the smooth floor Step 2 The screen aquarium is fixed with the rubber mats at the bottom Put the aquarium on the cabinet and make sure it is fixed to the cabinet firmly 2 Instructions for Components Connections _ UV Light 0z Feeder Switch g Left Pump E Feeder Motor n Right Pump Lamp Heater Temperature Sensor aT ares Figure 8 Component Connection The waterproof socket connectors of the fitting lines between controller outlets and component leads are matched and labeled to facilitate the connection of the aquarium s electronics V Functions of the Electronic Panel 1 Ilcon and Display Tear Month A Dae mi ahas emperat 98 18 c 088 dg 9G 88E T a work in tine FJ Fa F3 amj uto mode Ending time EE Manu
15. fill water from right side where LCD Control Panel and electronics is located to avoid getting any electrical components wet IMPORTANT Water should not exceed the Maximum water line or it will start to overflow from left side of the aquarium until back to Maximum water line We recommend using filtered or spring water when adding water to avoid excess minerals found in tap water Tap water is acceptable but typically tends to be harder If you choose to use tap water we recommend using aquarium salt to soften the water and add electrolytes that are better for the fish Water conditioner should be used to remove any trace elements and chloramines found in the water Step 11 Connect Waterproof Connectors Connect the waterproof connectors matching the male and female connectors For your safety we have intentionally disconnected some connectors Step 12 Turn on Aquarium Power Step 13 Add Fish After 48 hours of cycling the water in the aquarium you can now add fish to build up the natural bacteria for optimal filtration To cycle the aquarium we recommend adding no more than 1 3 fish to start Wait 4 6 weeks before adding more fish Never add more than 2 3 fish at a time Prior to adding new fish we recommend changing 15 of the water in your aquarium to remove ammonia and nitrate build up Maximum number of fish in the aquarium will vary but we typically recommend no more than the generally accepted rule of 1 inch o
16. g beyond the water might cause damage to it or for it to burn out D If manually turned off the water pump will temporarily stop for no longer than 30 minutes After 30 minutes the water pump will get back to work again E The pumps will turn off for 10 mins when the automatic feeder is turned on in order to not disturb the food while the fish eat Note The right pump will not stop if the heater is working To Turn the Water Pump On Off Manually The pump is pre programmed and must stay on factory settings However the water pump can be manually turned on or off To manually amp operate a pump press the pump icon the icon flickers iruie water pump is working and will not flash if it is turned off Please note that the water pumps will both shut off when the automatic feeder operates CAUTION The water pump must only be operated under water Operating the water pump outside of water can result to damage to the water pump and possibly lead to electrical shortage or fire The water pump should be installed in the filter box and should not less than 15mm deep into the water from the top or it will affect the working life of the device 2 8 Auto Feeder Function Description The default feeding time is at 9 00 AM and at 17 00 PM Operation Description A Manual Operation Touch icon E when icon flashes the function starts B Programming Instruction 1 Touch SET icon while SET icon flashes 2 touc
17. h icon w the P1 and P2 icon amp _ will appear 3 touch P1 to set the starting time of P1 and the same with P2 The feeder will automatically rotate one time to feed the fish so there is no need to set the ending time IMPORTANT A While the feeder is working the water pump and heater will automatically stop for 10 minutes so that the fish food will not be disturbed by the filtration system B Inorder to avoid over feeding the feeder can be set for maximum 3 times if you need to set feeding for more than 3 times please restart the control panel and set again However we recommend feeding 1 time per day as adequate C Overfeeding can lead to increased nutrients and harmful ammonia and nitrates in the aquarium water which is harmful to the fish D Only feed your fish what they can consume in 2 minutes 2 9 Carbon Dioxide CO2 Supplier The CO2 supplier should be installed on the right side inside the aquarium below the water pump outflow IMPORTANT NOTE The CO2 supplier should only be used if you intend to keep live plants in your aquarium Otherwise it does not need to be put into the aquarium If used the CO2 supplier should be replaced approximately every 10 12 weeks Replacement CO2 suppliers can be purchased from your distributor or from our Company Function Description The Carbon Dioxide CO2 supplies CO2 to live aquatic plants to promote photosynthesis and healthy growth IMPOR
18. hich the product manufactured 4 OBTAINING WARRANTY SERVICE Please access and review the online help resources before requesting warranty service If the product is still not functioning properly after making use of these resources please contact the HIMAT representatives using the information provided in the documentation A HIMAT representative will help determine whether your product requires service and if it does will inform you how HIMAT will provide it HIMAT will provide warranty service on products that are tendered or presented for service during the Warranty Period as permitted by law You are responsible for shipping and handling charges to ship the product to HIMAT or HIMAT representative for service In accordance with applicable law HIMAT may require that you furnish proof of purchase details and or comply with registration requirements before receiving warranty service For troubleshooting or questions please visit our website or contact Aquavista Enterprise Inc 1752 Junction Avenue Unit E San Jose CA 95112 408 453 4151 phone 650 240 3955 fax info aquavistainc com www aquavistainc com
19. hours per day Over lighting can lead to increased algae growth and higher water temperature The lighting system should not touch water and is not to be submerged into the water Lamps should be above the water at least 15mm or it may cause injury and damage to the aquarium 2 4 Air Pump Function description There are 3 programmable periods for the air pump The default settings are 9 00AM 11 00AM 14 00PM 16 00PM and 19 00PM 21 00PM Operation Instruction 2 a an Q A Manual Operation Press O2 supply icon the icon flickers the air pump starts to work B Programming Instruction To change the default setting 1 press SET icon and then press O2 icon 2 When P1 P2 P3 icon EEZ ES display press P1 to set the starting time 3 Press the END icon to set the ending time 4 P2 and P3 programming method is the same as programming P1 C Press SET icon to save the setting D If you need to stop the working period of P1 P2 P3 you can press the END digital for 5 seconds when the P1 P2 or P3 are flickering Press START for 5 second to re start and the time of OFF can restore to display WARNING The air pump supplier cannot be placed in the water it should be place at least 15mm above water level 2 5 UV Light NOT INCLUDED BUT WILL BE AVAILABLE FOR PURCHASE AS AN OPTIONAL ACCESSORY Please contact your distributor for more information Function description The ultr
20. le for purchase through your local dealer or distributor 2 Fish Care Accessories Included Actual item sent will be comparable but may be different than pictures 1 2 3 4 Water Siphon Picture 1 Fish Net Picture 2 Extendable Claw Picture 3 Algae Scraper Picture 4 ce EN QS mo N Picture 1 Water Siphon yond _ ba Picture 3 Extendable Claw Picture 4 Algae Scraper III Wall Mount Aquarium Installation Guide IMPORTANT Do not hang the aquarium in an area that has large amounts of direct or indirect natural sunlight as it will promote algae growth in the aquarium Step 1 Select the wall you want to hang the aquarium Make sure that you select a wall that has studs that you can secure the mounting bracket to Suggested height for hanging the aquarium is eye level or approximately 1 3 1 4m Note As the aquarium has a side mounted LCD control panel on the right side so it is recommended to leave enough room to access the side panel recommended 12 inches Step 2 Figure 4 below provides approximate suggestion for determining the spacing of the mounting brackets 840mm 175mm 175mm Suggested height 1 3 1 4 Suggested height 1 3 1 4 Ground Ground Figure for W1250 W1380 W1680 W1480P W1780P Suggested height 1 3 1 4 Suggested height 1 3 1 4 Ground Ground Figure for W1980 W2280 Figure for W2580 W2880 W2080P W3080P W2680P W2980P Figu
21. n icon the icon flashing which means the function has been started Turn off function Press the unlock icon for 3 seconds the icon flickers with buzzing which means the operation panel have started Press any function icon that is flashing the icon will stop flashing which mean the function has been started The control panel will save any setting automatically If you want to restore the aquarium to default settings please press SET icon for 5 seconds N OO NO 2 11 Selection of Automatic Mode and Manual Mode For LCD panel with Manual mode Function Description We provide automatic mode and manual mode for LCD panel with Manual mode you can choose either mode according to your need Operation Description A Touch AUTO icon while icon flashes automatic mode is selected B Touch MAN icon while icon flashes manual mode is selected Under manual mode all the functions are operated by manual C The default setting is in automatic mode you can choose manual mode according to your needs 2 12 Calibrating the LCD Touch Screen If the keypad is not responding properly to your touch it may be necessary to calibrate the touch screen keypad Instruction A Step 1 Cycle the aquarium power on and off two times Turn the power switch on and off two times within 10 seconds After the second time the power is turned on the LCD screen will enter the screen calibration mode with fli
22. ntrol the main board is panel used out M Replace battery on control panel Darkening or dim Light bulb has M Replace light bulb lighting burned out It is strongly suggested that users do not choose electronic components randomly but buy the special waterproof parts from our distributors agents 4 Maintenance of Filter 1 Switch off power supply screw off the water proof connectors of the left and right water pumps heater O2 supplier and other electronic spare parts 2 Take out the rubber cover of the left and right filter and take out the filter heater biochemical fiber UV light one by one 3 Clean the filter 4 Install the filter equipment and rubber cover of the filter one by one and connect to waterproof connector according to the label PRODUCT WARRANTY HIMAT ELECTRICALAPPLIANCE CO LTD provides a LIMITED WARRANTY of six months on electronic parts and ONE YEAR against tank leakage Please contact our representatives directly should you need any service or assistance with your aquarium prior to return 1 WARRANTY COVERAGE HIMAT warranty obligations are limited to the terms set forth below HIMAT as defined below warrants this HIMAT branded hardware product against defects in materials and workmanship under normal use for a period of SIX MONTHS ONE YEAR from the date of production Warranty Period If a hardware defect arises and a valid claim is received within the Warranty Period at its option o
23. ocess the installation procedure in the manual guideline To the extent permitted by law this warranty and remedies set forth above are exclusive and in lieu of all other warranties remedies and conditions whether oral or written statutory express or implied As permitted by applicable law HIMAT specifically disclaims any and all statutory or implied warranties including without limitation warranties of merchantability itness for a particular purpose and warranties against hidden or latent defects If HIMAT cannot lawfully disclaim statutory or implied warranties then to the extent permitted by law all such warranties shall be limited in duration to the duration of this express warranty and to repair or replacement service as determined by HIMAT in its sole discretion No HIMAT reseller agent or employee is authorized to make any modification extension or addition to this warranty Except as provided in this warranty and to the extent permitted by law HIMAT is not responsible for direct special incidental or consequential damages resulting from any breach of warranty or condition or under any other legal theory including but not limited to loss of use loss of revenue loss of actual or anticipated profits including loss of profits on contracts loss of the use of money loss of anticipated savings loss of business loss of opportunity loss of goodwill loss of reputation loss of damage to or corruption of data or any
24. re 4 Suggested Mounting Height and Bracket Position Step 3 Locate STUDS in wall Using a stud finder identify the most solid portion of the wall so that you can secure the mounting brackets to the wood studs For the cement screws cement wall only Drill holes of at least 80mm in depth one by one with a 14mm impact drill Fix the screws through the holes in the brackets hammer the anchor screws into the wall fasten the screws M10 60mm to the drilled holes with the wrench Figure 5 ALL THREE HOLES IN THE BRACKET SHOULD BE USED AND PROPERLY SECURED Bracket 9 o drilled hole Figure 5 Mounting Brackets use screws in all six holes Step 4 Use a Leveler to align brackets Make sure the brackets are level so that when aquarium is rested and hung onto the brackets it will sit evenly and flat parallel Step 5 Make sure each screw is secured properly and will be able to bear the weight of the aquarium Note For walls which do not have enough hardness first drill holes of 120mm deep and stuff them with high strength cements When the cements are hardened drill holes and fix the aquarium Step 6 Secure Aquarium onto brackets and clips Lift the aquarium on to the mounting brackets and fix the clips to the groove at the top of the aquarium and bracket Figure 5 Make sure brackets are spaced properly apart and the aquarium s weight is properly distributed The clip
25. s attach the aquarium to the mounting brackets and prevent the aquarium from tipping forward and should be fit securely to the top of the aquarium and the mounting bracket IMPORTANT Clips and Brackets should be parallel and flush to the top of the aquarium so that the aquarium will not tip forward Figure 6 Bracket and Clips Assembly Maximum Water Line THR Gif as Si TEA n a a SS Sr ene Seo hn ee a eee inte ene eae feet Wisse thoes a bo Bee FB SRR AS ee add posh RRS BHA RRS Hebe Ghee pisses Sands amp Stones Bottom of nner Tank Figure 7 Inside Tank Step 7 Spread sand or gravel not included the bottom of inner tank for 40 55mm in depth See Figure 7 Make sure you rinse the gravel prior to putting into the aquarium in order to remove excess dust particles Step 8 Set up the Air Pump Connect the O2 tube to the air stone in the middle of the tank bottom and cover with sands amp stones Note The air stone can be found in one of the boxes of accessories included with aquarium Do not cover the air stone too deep into the sand amp stones and be careful not to block the air flow Decorative or other air stones can be used to connect to the air tube as well Step 9 Decorate Add decorations live or fake aquatic plants into the aquarium according to personal taste Step 10 Add Water Fill the aquarium with water from the upper left side Do not
26. steel mounting brackets in order to avoid personal body injury Children should not be allowed to play near the aquarium in order to avoid any hitting injuries or causing damage to the aquarium Please clean the outer frame gently with soft cloth Never use an abrasive material or chemical cleaner to clean the surface of the aquarium to avoid scratches Please use the special sponge to clean the inside aquarium gently If there is any problem with the unit do not attempt repairs yourself Please contact the authorized dealer or our company Repairing the unit yourself may result in potential injury orharm The Company will not be liable for such responsibility This product comes with a six month warranty on electric parts excluding light bulbs and carbon dioxide supplier and one year on the tank body See Product Warranty for details All descriptions and data in this manual are subject to change without prior notice Wall Mounted Aquarium amp Screen Aquarium Overview NOTE FOR ILLUSTRATION PURPOSES THE AQUARIUM CONTROL PANEL IN THIS MANUAL WILL APPEAR ON THE FRONT OF AQUARIUM Figure 1 LCD Touch screen Control Panel Super Silent Water Pump Intelligent Thermostat Flourescent Lighting UV Light Not Included Auto feeder Super Silent Air Pump Biochemical filtration system Carbon Dioxide CO Supplier 1 Main Body With LCD panel Air Pump Auto F eeder Fix it to
27. ter should work together with circulation filtration system C When the preset temperature is the same or lower than the current temperature display on the LCD panel the heater will not turn on D The heater in the aquarium should keep the water above the set temperature It does not act as a chiller so if the water temperature is above the programmed temperature setting the heater will remain off and the aquarium temperature may read higher than the programmed temperature Note Most likely the aquarium water will stay around ambient room temperature typically a few degrees above 2 7 Water Pumps Circulation Filtration Biochemical Function The water pump promotes biochemical filtration and has a default program that is set to work for 24 hours every day sometimes alternating cycles IMPORTANT The water pump cycle cannot be programmed nor changed by users Overview A The filtration materials include biochemical fiber sponge and biochemical balls The sponge should be replaced every 3 months which will enhance filtration and help the survival and reproduction of nitrifying bacteria converts harmful ammonia to less harmful nitrates nitrites B Biochemical balls are inserted into the sponge which help purify the water and provide extra surface area for the nitrify bacteria to produce They should be taken out and cleaned every 3 months C The filter pump should never be operated outside of the water Workin
28. ur representative will either 1 repair the hardware defect at no charge using new or refurbished replacement parts or 2 exchange the product with a product that is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original product under HIMAT discretion HIMAT may request that you replace defective parts with new or refurbished user installable parts that HIMAT provides in fulfillment of its warranty obligation Areplacement product or part including a user installable part that has been installed in accordance with instructions provided by HIMAT assumes the remaining warranty of the original product or THIRTY 30 days from the date of replacement or repair whichever provides longer coverage for you When a product or part is exchanged any replacement item becomes your property and the replaced item becomes HIMAT s property Parts provided by HIMAT in fulfillment of its warranty obligation must be used in products for which warranty service is claimed Customer assumes all the shipping and handling cost 2 EXCLUSIONS AND LIMITATIONS This Limited Warranty applies only to hardware products manufactured by HIMAT or for HIMAT representatives that can be identified by the HIMAT trademark trade name or logo affixed to them The Limited Warranty does not apply to any non HIMAT hardware products or any software even if packaged or sold with HIMAT hardware Manufactur
Download Pdf Manuals
Related Search
Related Contents
Kenwood KDC-X492 CD Player User Manual Más información en pdf Processamento Dinâmico e EQ SCORM Best Practices Guide for Content Developers 1st Edition HA8000シリーズ 17型カラー液晶ディスプレイ 取扱説明書 GQ Copyright © All rights reserved.
Failed to retrieve file