1. REED ANNEER REED INNEN mm mm Define Custom Colors gt gt 3 2 2 Adjust Measure Analysis When the cursor is in pickup state press left button not to release drag the cursor to move those analysis targets In pickup state the cursor possesses the following forms a Move measure spot 2 2 Move measure line 3 Adjust the starting ending point M3 Move the whole area 5 Adjust area Select the measure area you are going to adjust click left button and 8 hot spots appear drag those hot spots to adjust the area size 6 Bl Move the whole polygon f Adjust Polygon 3 9 Histogram The histogram shows the statistical information of the current image temperature When adjusting the temperature slide bar in main window the histogram changes accordingly It is also possible to change the histogram color by adjusting the temperature slide bar in the histogram dialog box You can change the number of the current column in the Column Humber histogram by adjusting button The functions of the buttons in the toolbar are as follow from left to right A MEG a 1 The ordinate switches between percentage and absolute number 2 The histogram color switches between gradual change and consistency in red 3 Switches between to show gridding background and not 4 Save histogram as image in any format in common use 5 Change histogram background color 6 Switches b
2. 1 YEAR CARE C WARRANTY EM Shop online at omega com MEOMEGA OMEN PU u omega com RSce Softwar e mail info omega com For latest product manuals omegamanual info Version 2 0 System Requirements Windows 7 Windows XP MADE IN CHINA reru omega com 800 TC OMEGA 800 826 6342 COPYRIGHT 2011 OMEGA ENGINEERING INC OSXL160 IRSee Software omega com OO OMEGA OMEGAnet Online Service Internet e mail omega com info omega com U S A ISO 9001 Certified Canada Servicing North America Omega Engineering Inc One Omega Drive P O Box 4047 Stamford CT 06907 0047 USA Toll Free 1 800 826 6342 TEL 203 359 1660 FAX 203 359 7700 e mail info omega com 976 Bergar Laval Quebec H7L 5A1 Canada Toll Free 1 800 826 6342 TEL 514 856 6928 FAX 514 856 6886 e mail info omega ca For immediate technical or application assistance U S A and Canada Sales Service 1 800 826 6342 1 800 TC OMEGA Mexico Latin America Benelux Czech Republic France Germany Austria United Kingdom ISO 9001 Certified Customer Service 1 800 622 2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN En Espafiol 001 203 359 7803 FAX 001 203 359 7807 info omega com mx e mail espanol omega com Servicing Europe Managed by the United Kingdom Office Toll Free 0800 099 3344 TEL 31 20 347 21 21 FAX 31 20 643 46 43
3. io m l 1 2 System Requirements cccceeeecesessesesssssteeeeees l 1 2 1 Hardware Requirements l 1 2 2 Operating System Requirements l 1 3 Software Installation l 1 4 Starting up Software nnee 4 2 IRSee Report User Interface 5 2 1 Main Menu and Toolbar 5 2 1 1 5 2 1 2 VIEW eneen veveeevenn 5 2 1 3 Measure neee 6 2 1 4 Image nnen eneen ereen 6 Ze ke RODO ME 0 6 2 1 6 Note eene eene nennen ereen 6 2 1 Temperature nennen eneen 7 2 1 8 Window eenen vereen 7 2 1 9 Toolbar eener 1 3 IRSee Report Introduction 8 3 1 Add IR ATTICI gt ree ee 8 3 2 Analyze IR Image ee 8 3 2 1 Establish Analysis sss 8 3 2 2 Adjust Measure Analysis 12 3 3 Histogram ssssssssseee eene 13 3 4 Save IR Image and add Reference 13 3 5 Voice Annotation Playback cece eee 14 3 6 Temperature nnen 14 3 7 WINdOW 14 4 Image Adjustment 15 De Report T 15 1 Software Installation Welcome to Use IRSee Report 1 1 Introduction This IRSee Report version has a friendly user interfac
4. FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package a
5. e mail sales omegaeng nl Frystatska 184 733 01 Karvin Czech Republic Toll Free 0800 1 66342 TEL 420 59 6311899 FAX 420 59 6311114 e mail info omegashop cz Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0800 6397678 TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 e mail info omega de OMEGA Engineering Ltd One Omega Drive River Bend Technology Centre Northbank Irlam Manchester M44 5BD United Kingdom Toll Free 0800 488 488 TEL 44 0 161 777 6611 FAX 44 0 161 777 6622 e mail sales omega co uk It is the policy of OMEGA Engineering Inc to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for human applications OSXL 160 IRSee Software User Manual 1 Software Installation 1 Welcome to Use IRSee Report l Malie le Ulo
6. 0 56 28 4 LI 0 56 76 8 282 42 7 E 0 56 343 282 312 R1 0 56 79 7 27 9 33 6 1 Spot added spot analysis Click icon in measure toolbar and move cursor on IR image Click left button on the spot that you are going to measure Now the measure spots added in the IR image It is possible to add up to 20 measure spots The spots also can be added by clicking 8 sub menu Add Spot in menu measure After a spot has been added the attributes of this point will be showed in the marker box When the cursor is above the measure point it turns into MZ then click the right button to open the attribute and delete menu Select attribute menu the advanced attributes of the measure point will appear Object type Foint te 15 970 Coordinate Select delete menu to delete that spot 2 Line added line analysis Click icon in measure toolbar and move cursor on IR image Press left button on the point that you are going to measure not to release until drag it to the end point Now a measure line has been fixed It is possible to add up to 10 measure lines The lines can also be added by clicking sub menu Add line in menu measure After adding a line the basic attributes of this measure line will appear in the marker box When the cursor is above the measure line it turns into 3 then click the right button to open the attribute and delete menu Select attribute menu the advanced attributes of the measure l
7. A s Customer Service Department will issue an Authorized Return AR number immediately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS
8. Assemblies Lef Wire Thermocouple RTD amp Thermistor IA Calibrators amp Ice Point References bf Recorders Controllers amp Process Monitors Lef Infrared Pyrometers PRESSURE STRAIN AND FORCE bef Transducers amp Strain Gages Lef Load Cells amp Pressure Gages lt Displacement Transducers l Instrumentation amp Accessories FLOW LEVEL bef Rotameters Gas Mass Flowmeters amp Flow Computers bef Air Velocity Indicators bef Turbine Paddlewheel Systems l Totalizers amp Batch Controllers pH CONDUCTIVITY Lef pH Electrodes Testers amp Accessories l Benchtop Laboratory Meters Lef Controllers Calibrators Simulators amp Pumps Lef Industrial pH amp Conductivity Equipment DATA ACQUISITION Lef Data Acquisition amp Engineering Software IM Communications Based Acquisition Systems bef Plug in Cards for Apple IBM amp Compatibles bef Data Logging Systems bf Recorders Printers amp Plotters HEATERS Lef Heating Cable bef Cartridge amp Strip Heaters Lef Immersion amp Band Heaters bef Flexible Heaters Lef Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL bef Metering amp Control Instrumentation Lef Refractometers Lef Pumps amp Tubing lA Air Soil amp Water Monitors bef Industrial Water amp Wastewater Treatment Lef pH Conductivity amp Dissolved Oxygen Instruments M5046 0711
9. e 4 methods for measure analysis and the function to save analysis report in Microsoft Word format 1 2 System Requirements The files of the IRSee Report consist of IR image visible light photo and graphic file all of which are far bigger than normal text files thus the following standards of the computer hardware configuration should be met 1 2 1 Hardware Requirements CPU PENTIUM III with 1 4 GHz processor or faster 256 MB RAM or above HD space above 20GB Screen resolution above 1024 x 768 1 2 2 Operating System Requirements IRSee Report is compatible with Microsoft Windows 2000 XP or Vista It provides a multi language version for users 1 3 Software Installation The instructions of IRSee Report installation and necessary precautions before using this software will be given in detail hereinafter Please follow the instructions when installing IR Analysis software application Place software CD ROM into CD drive and run setup exe in the CD root directory The default route is C Program Files IRSee Report You can change directory when installing Attention users who are operating Vista please close user account control to prevent warning e After running setup exe the system shows a welcome interface IRSee Report Setup Ed G Welcome Welcome to the installer for IRS ee Report 2 0 0 2 It ig strongly recommended that you exit all Windows programs before continuing with this instal
10. etween to show the exceeding column and not 7 Reset the histogram as initial state 3 4 Save IR Image and add Reference Click reference image under image menu to open a box showed in the following picture and add a visible light image 13 Click add image button to add an image Click remove image button to delete an image If a visible light image has been added it will be showed automatically in the report After finishing IR image analysis click save image in image menu to open the following box 3 9 Voice Annotation Playback If the IR image contains voice annotation data the audio button in measure toolbar is in active state otherwise it is in inactive state gray Click this icon to open the voice dialog box Click play pause continue and stop to operate the voice record 3 6 Temperature Click pull down menu Celsius Fahrenheit in Temperature menu to switch between Celsius and Fahrenheit The default is Celsius Celsius Fahrenheit 3 Window There are 3 sub menus in the Window menu new cascade and tile 14 4 Image Adjustment Click the pull down menu at the right of color palette There are 12 different color codes The image will show in different color according to different color code The slide bar below the image denotes the temperature the camera has been set when taking IR images The two ends of the slide bar denote the upper lower limit temperature of the color code Adjust u
11. ine will appear Display the highest a oss that the lowest temperature temperature Object typeiLine Maximum 131 9 Minimum 12 6 C Average 51 8 C i Cancel Select display highest lowest temperature item the maximum minimum temperature will be showed in the measure line icon denotes the maximum temperature and icon denotes the minimum temperature Select delete menu to delete that measure line If you want to get a visualized picture of the temperature trend of the measure line click Line Measure in sub menu View ae ee CURSOR 36 56 C 129 164 41 3 C 13 1T1 When the cursor is on the black vertical line it turns into click left button not to release to drag the black vertical line and change the cursor position accordingly 3 F Area added Area analysis 10 Click icon on measure toolbar and move cursor on IR image Press left button on the point that you are going to measure not to release until drag it to the end point Now an area has been fixed Up to 20 areas can be added The areas can also be added by clicking Add area in menu Measure After an area has been added the attributes of this area will be showed in the marker box When the cursor is inside the measure area it turns into ES then click the right button to open the attribute and delete menu oelect attribute menu the advanced attributes of the measure area will appear O Shows that the lowe
12. lation i IF You have any other programs running please click Cancel close the programs and run this setup again Otherwise click Next to continue Select Next IRSee Report Setup Installation Folder Where would you like IR See Report to be installed The software will be installed in the folder listed below To select a different location either type in new path ar click Change to browse for an existing folder Install IRS ee Report to C Program FilextIR See Report Space required 14 2 MB Space available on selected drive 21 32 GB Cancel the system shows the default route Press Browse to change the route 2 IRSee Report Setup Ready to Install Tou are now ready to install IHS amp ee Report 2 0 0 2 The installer now has enough information to install IA See Report on sour computer The following settings wall be used Install folder CA Documents and SettingssvangsMy Documents Shortcut folder IRSee Report Please click Nest to proceed with the installation Cancel select Next the system will copy IRSee Report into PC Or select Back IRSee Report Setup Installation Successful The IH See Report 2 0 0 2 installation i complete Thank you for choosing IHSee Report Please click Finish to exit this installer Select Finish to confirm installation 1 4 Starting up Software The following icon appears on Windows desktop after installing IRSee Report Doub
13. le click the icon to startup IRSee Report FiletE View Y Helpig DE M gt BS Y M LL X Open an image by menu file open or icon in the toolbar HE poa Arce lyser fterare hres FET PEER Vise Beurre Image apart Tets Tm Tiaia Osi tae b OGEXE MM Image raper The klare CiiSaenmale Image Date 2070 11 01 Device HDT EO Ambien 241 v Humidity su page Distante LE m Emissiviny 0 55 X Pene E Det Dore ev 4 1 754 754 Wferrsatian Cela Emin Max Mn Zan Select a working language by menu view Language IR Analysis software has 10 different working languages namely English Italian Chinese simplified amp traditional Japanese Russian French German Korean Spanish and Portuguese After selecting a language a dialog box appears Press YES to confirm 2 IRSee Report User Interface IRSee Report is a standard Windows application and compatible with Windows 2000 XP and Vista It supports all common Windows operations 2 1 Main Menu and Toolbar There are 8 items in the main menu namely File View Measure Image Report Note Temperature and window File View Measure Image Report Mote Temp Window 2 1 1 File There are 4 items in File sub menu New Open Close and Exit NewiN Ctrl N Opent Ctrl CloselPl Ctrl F Exit E Ctrl4E 2 1 2 View There are 4 items in View sub menu Toolbar Stat
14. nd on any correspondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the FOR NON WARRANTY REPAIRS consult OMEGA following information available BEFORE for current repair charges Have the following contacting OMEGA information available BEFORE contacting OMEGA 1 Purchase Order number under which the product 1 Purchase Order number to cover the COST was PURCHASED of the repair 2 Model and serial number of the product under 2 Model and serial number of the product and warranty and 3 Repair instructions and or specific problems 3 Repair instructions and or specific problems relative to the product relative to the product OMEGA s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2011 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without the prior written consent of OMEGA ENGINEERING INC Where Do I Find Everything I Need for Process Measurement and Control OMEGA Of Course Shop online at omega com TEMPERATURE Lef Thermocouple RTD amp Thermistor Probes Connectors Panels amp
15. nimum temperature of the line or the area temperature trend picture of line measure and histogram etc 16 kne Dag 17 If reference image is selected and the image has been added the report contains the following data IR image visible light image target parameter form result analysis form which contains point temperature the maximum minimum temperature of the line or the area temperature trend picture of line measure and histogram etc 18 IE Imre Exslyziz He port A Compal Coapa EF reci DrjectenlLhk Ee e EN EA C E Hext bess ton Inns Ir Mare Mei trew e Tape EL d EE En gs Easit Information 2011 01 24 1 a Target Di tices 10m a Cog Phe kets E e l Fro tkm ul Msa ms 1 19 HuER SY Lal m 4 8 ae AVR C UTC p 39 0 C a0 B C IZA its 38 Tmgsra zral Ci If the computer has been installed with Microsoft Word software the reports can be edited in Word document 20 WARRANT Y DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA s WARRANTY adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that OMEGA customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEG
16. pper lower limit width of the color code to change the image color 20 0 34 4 51 3 250 0 9 Report 1 Edit Report Click Edit Report sub menu in Report menu to open edit dialog box DAOMEGE jpg Filling in company name company address and inspector name in the form click right button in the blank area of the LOGO line to open add delete image dialog box by using which User can add delete image After filling a user defined report header is created 2 Description Click Description submenu in Report menu to open Edit dialog box 15 Object Name 220kV transformer Object Position po euer Road Object Type Object Number 10001 001 Maintenance Level Grade One Inspection Date 2010 08 08 ext Inspection Time 2011 08 08 Problem Description The items hereinabove will be exported automatically in the report 3 Export report Two kinds of reports can be exported the default report and the user defined report The default report contains Information header of OMEGA company If end users need header that contains your own corporate information please edit the report and export that report The saving route of the document can be changed After clicking save button the IR Analysis software will create a Word report automatically If reference image is not selected the report contains the following data IR image target parameter form result analysis form which contains spot temperature the maximum mi
17. st temperature Object type Rect MWaximum 156 4 Select display highest lowest temperature item the maximum minimum temperature will be showed in the measure area icon denotes the maximum temperature and icon denotes the minimum temperature Select delete menu to delete that measure area 4 Irregular Polygon added Irregular Polygon analysis Click icon on measure toolbar and move cursor on IR image Click left button to fix the borderline of the Polygon click right button to confirm it Up to 10 measure Polygons can be added The Polygons can also be added by clicking sub menu Add Polygon in menu Measure After a Polygon has been added the attributes of this Polygon will be showed in the marker box When the cursor is inside the measure Polygon it turns into E click the right button to open the attribute and delete menu Select 11 attribute menu the advanced attributes of the measure Polygon will appear 9 Isotherm analysis Select isotherm analysis check box JSOTherm within image selection box Set the upper lower limit temperature of the IR image by upper lower limit temperature slide Now the range of the isotherm color will be displayed within the image Press isotherm analysis check box again to cancel isotherm analysis The default isotherm color is green Click the color zone to open color selection box and change the color Cl i mu 3 D 5 m pa BE Ei
18. us Bar Line Measure and Histogram v Toolbar T vw Statusbar 5 Measure Line fL Histogram 2 1 3 Measure There are 4 items in the Measure sub menu Add Spot Add Line Add Rect and Add Polygon Add Spot Add Line Add Rectangle Add Polygon 2 1 4 Image There are 2 items in the Image sub menu Reference Image and Save Image Reference mage cave Image 2 1 5 Report There are 3 items in the Report sub menu Export Report Edit Report and Description Export Report Edit Report Description 2 1 6 Note Note sub menu contains Voice Annotation item If the image is stored without voice annotation this item is gray 2 1 Temperature There are 2 items in this sub menu Celsius and Fahrenheit Celsius Fahrenheit 2 1 8 Window There are 3 items in this sub menu new cascade and tile Mew Window NW Cascade C1 Tile T w 1 Untitled 2 1 9 Toolbar bct z Sg XX MA 3 IRSee Report Introduction 3 1 Add IR Image Click button in the toolbar or File open to add an IR image If there are more than one image in one folder use EN or ES button to select an image 3 2 Analyze IR Image 3 2 1 Establish Analysis Add an IR image to analyze it There are 4 analysis methods Spot Line Area and Irregular Polygon analysis The result displays in the Marker box Option lsOTherm EM 2 3 of ae S 0 fa Information Color Object Emissietty Max fin Ave