Home

User Manual

image

Contents

1. STEP 10A Remove Mattress Retainer Bar C from the bottom of the foundation STEP 10B WARNING When placing the foundation s Remove the Retainer Bar Plates D and Retainer Bar within a bed frame verify the space between Screws E from the accessory bag also attached to the the headboard cross member and the top of the bottom of the foundation mattress is no more than 3 inches STEP 12 Ensure the power switch on the surge protector is in the on position and that it is plugged into the wall outlet Check the system for functionality with the mattress in place SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Installation Instructions For Joining Two Foundations ONE WIRED REMOTE CONTROL AND TWO REFLEXION UP FOUNDATIONS Assembling Split Dual Foundations Frame A and Frame B to be used together as a single King or CA King system NOTE The use of Frame A and Frame B is for description purposes only and the beds will not actually be labeled Frame A or Frame B NOTE Wired Remote Control and Y Cable are attached to underside of the Reflexion UP Foundation for shipping STEP 1 Carefully unplug the Wired Remote Controls from Frame A and Frame B STEP 2 Remove both Wired Remote Controls and set aside Place the spare remote control in a safe place for any future use STEP 3 Remove and extend one of the provided Y Cables from the frame STEP 4 Plu
2. DAS D OPTIMUM sap Posturepedic SEALY POSTUREPEDIC Reflexion UP Foundation Complete Reference Guide Patents pending 2014 Sealy Inc All Rights Reserved 06485100 4 16 2014 Reflexion UP Foundation Limited Warranty for Reflexion UP Foundation SEALY WARRANTS THAT IT WILL AT SEALY S OPTION REPLACE OR REPAIR PURCHASER S REFLEXION UP FOUNDATION IF IT IS DEFECTIVE DUE TO FAULTY WORKMANSHIP OR MATERIALS SUBJECT TO THE LIMITATIONS DESCRIBED IN THIS WARRANTY SEALY UNDERTAKES NO RESPONSIBILITY FOR THE QUALITY OF THE GOODS EXCEPT AS OTHERWISE PROVIDED IN THIS WARRANTY THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE THEREOF THIS WARRANTY APPLIES ONLY TO REFLEXION UP FOUNDATION THIS MODEL MAY BE IDENTIFIED BY REFERENCE TO THE SERIAL NUMBER ON THE PRODUCT YEARS 1 THROUGH 3 FULL COVERAGE OF PARTS AND LABOR Reflexion UP Foundation is warranted against defects in the workmanship or materials for a period of three 3 years from the warranty commencement date During these first three years of the Warranty the entire product is so covered including factory supplied electronics electrical components drive motors and power supply components Upon notice during the first through third year from the Warranty commencement date Sealy will send replacement parts to the Purchaser at no cost in order to replace any such defective part In addition Sealy will pay all authorized la
3. up to 650 Ibs each this Warranty is void Replacement parts may be new or reconditioned at Sealy s discretion Except for the 15 Year Warranty provided for the frame of this product there is no warranty at all after five years dating from commencement of this Limited Warranty ADDITIONAL LIMITATIONS ON WARRANTY COVERAGE In the event a warranty claim is filed and a warranty replacement is deemed necessary purchaser will be required to surrender the original product including any components to Sealy at the time of the replacement Return of the Base however should it need to be replaced is not required Repairs to or replacement of the Sealy Reflexion UP Foundation or its components under the terms of this Limited Warranty will apply to the original warranty period and will not serve to extend such period This Warranty begins on the warranty commencement date which is the date of purchase for new unused products If you did not purchase this Sealy Reflexion UP Foundation directly from Sealy proof of purchase will be required to demonstrate that you are the original purchaser and eligible to make a valid claim under this Warranty Warranty If original proof of purchase is not provided by the purchaser Sealy reserves the right to determine if the unit is covered or is not covered by this Warranty and may use the manufacturing date as the warranty commencement date The decision to repair or to replace defec
4. Failure to have a proper bed frame may invalidate the Warranty This Warranty and other performance warranties are based on tests conducted on sets that consist of our mattresses and foundations Sealy foundations should be placed on a bed frame that is structurally capable of supporting the weight of the purchaser s Sealy mattress foundation and user s IF PURCHASER USES INAPPROPRIATE BED FRAMES WITH THIS FOUNDATION SUCH USE WILL VOID THIS WARRANTY AND ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Sealy may require proof of the quality of bed frame if purchaser makes a claim under this warranty Sealy reserves the right to invalidate this warranty if the foundation is found to be in an unsanitary condition The Consumer Product Safety Commission has created the Standard for the Flammability Open Flame of Mattress Sets in Federal Register 16 CFR Part 1633 Foundations are specified for use with particular mattresses and therefore use outside of these specifications should not be construed as 16 CFR Part 1633 compliant SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 ADDITIONAL TERMS AND CONDITIONS In no instance will this Warranty cover any damage attributable to misuse or to normal wear and tear or to excessive weight placed upon the product Nor will this Warranty cover any purchaser other than the origina
5. damaged cord or plug is not working properly has been dropped or damaged or dropped in water Return the furnishing to a service center for examination and repair e Keep the cord away from heated surfaces SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 SAVE THESE INSTRUCTIONS GROUNDING SAFETY SERVICING OF DOUBLE INSULATED PRODUCTS In a double insulated product two systems of insulation are provided instead of grounding No grounding means is provided on a double insulated product nor is a means for grounding to be added to the product Servicing a double insulated product requires extreme care and knowledge of the system and is to be done only by qualified service personnel Replacement parts for a double insulated product must be identical to the parts they replace A double insulated product is marked with the words DOUBLE INSULATION or DOUBLE INSULATED The symbol Square within a square El is also to be marked on the product Unauthorized modifications could void the electrical portion of your warranty FOR BEST RESULTS THE REFLEXION UP FOUNDATION SHOULD BE PLUGGED INTO A SURGE PROTECTOR not included WARRANTY PRECAUTION Do not open control box motors or remote control with the exception of the battery compartments The warranty is void if these units are tampered with Any repair or replacement of Reflexion UP Foundation parts must be performed by an authorized service person IN HOM
6. E Aftermarket legs and casters are available for purchase If purchased attach Reflexion UP Foundation Legs by following instructions included with accessories NOTE Hand tighten the legs securely to the frame DO NOT over tighten Make sure the legs are screwed completely into the frame Legs that are not securely attached may become unsafe DO NOT unscrew a leg to compensate for an uneven floor NOTE In order to prevent the movement of this product all four casters should be in the locked position SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Reflexion UP Foundation STEP 7 STEP 10C If this delivery involves dual foundations and or Install Mattress Retainer Bar C and install Retainer split mattresses see instructions for joining two Bar Plate D foundations on page 15 STEP 8 Carefully flip the Reflexion UP Foundation s over to the topside up position NOTE Make sure to lift the foundation s off the ground before flipping over DO NOT use legs as a leverage point to ensure they do not break STEP 10D Hand tighten Retainer Bar Screws E NOTE Do not overtighten or use power tools AN ATTENTION Improper handling for installation DO NOT lean the bed against the installed legs to flip it over STEP 9 Route the control box cable to your preferred side of the bed STEP 11 Place the mattress es on the foundation s STEP 10 Installing the Mattress Retainer Bar C
7. E USE AND HOSPITAL DISCLAIMER Your Reflexion UP Foundation is strictly designed for in home use only It is NOT designed for hospital use and is NOT designed to meet hospital standards DO NOT USE this bed with TENT TYPE oxygen therapy equipment or near explosive gases Reflexion UP Foundation WARNING FOR HOUSEHOLD RESIDENTIAL USE ONLY DO NOT USE OUTDOORS CAUTION Risk of electric shock Dry location use only SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 IMPORTANT SAFETY FEATURES Use this furnishing only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer If there is an overload weight condition on the head mechanism the control unit will automatically stop the corresponding functions Once the excess weight is removed the control unit will automatically allow all functions to resume Legs and locking casters are available for aftermarket purchase In order to prevent the movement of this product with casters all four casters should be in the locked position This can be accomplished by pushing down the locking latch on the caster To resume mobility of the product lift the locking latch up You are strongly encouraged to place rubber caster cups or carpet squares under the casters in addition to locking them in place if the product is positioned on a hard surface floor such as hardwood tile or linoleum Although the casters are locked and
8. R SERVICE DEPARTMENT 1 800 499 1965 Reflexion UP Foundation PRODUCT RATINGS INTENDED USAGE The lift motor in the Reflexion UP Foundation is NOT The electric adjustable bed should be installed with designed for continuous use Reliable operation and the head of the frame positioned close to a wall full life expectancy will be attained as long as the lift motor does not operate more than two 2 minutes over a 20 minute period or approximately 10 duty cycle Any attempt to circumvent or exceed this rating will shorten the life expectancy of this product and may void the warranty The recommended weight restrictions on our Reflexion UP Foundations are as follows Twin Twin Long Double Queen and Split Dual CA King foundations up to 650 Ibs each This Reflexion UP Foundation will structurally support the recommended weight distributed evenly across the entire length of the foundation This product is not designed to support or lift this amount of weight in the head section alone NOTE Exceeding the recommended weight restrictions could damage your Reflexion UP Foundation and void your warranty For best performance you should enter and exit the Reflexion UP Foundation while it is in the flat or fully lowered position SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Questions and Answers Commonly asked Questions and Answers WHAT IS THE HEIGHT OF THE REFLEXION UP FOUNDATION The Reflexion UP Foundation
9. RVICE DEPARTMENT 1 800 499 1965 Pre Delivery Procedure STEP 1 Lift carton top off box to reveal the bottom of the foundation STEP 2 Using a power extension cord to reach the foundation plug in the foundation s power cord NOTE Do not uncoil the foundation power cord which is packaged for shipment STEP 3 Slide the cover off the battery compartment on the power supply and install the provided 2 9 Volt Batteries F Replace the battery compartment cover NOTE Do not mix old and new batteries STEP 4 Cut the plastic strapping on each Wired Remote Control from the foundation frame Ensure that the wired remote is connected to the foundation STEP 5 Power Test Procedure Press each of the following buttons long enough to illuminate the blue LED backlight on the remote control and watch listen for the foundation to activate This ensures you will be delivering a foundation that is fully functional Test the foundation by pressing the buttons in the following sequence 1 Head Lift 2 Flat NOTE Only press each button long enough to hear or see the function activate on the foundation Reflexion UP Foundation STEP 6 Once the warehouse test is successful and complete e Unplug the power extension cord e Place the lid back on the outer carton and secure for delivery NOTE Always keep the foundation in a flat horizontal position during transportation and delivery NOTE To avoid
10. TAIN THIS WARRANTY PAPERWORK AND ORIGINAL SALES RECEIPT FOR EASY FUTURE REFERENCE AND DOCUMENTATION SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Reflexion UP Foundation Table of Contents WARRANTY cise rec acc cc ee cee ves Ran PRECE a EEEE 2 SAFETY PRECAUTIONS susto essa piada aa dinda iii os o bau ainda onda 5 COMMONLY ASKED QUESTIONS AND ANSWERS ccccceseceseeeseeeeeeeeeeseneeeeeonseeeeeneeessoeees 9 SPECIFICATIONS csquaaonanniceassodiaes asno nasans dice dana ico cansa ini ai adia ba in no e 10 INSTALLATION Installation Instructions o ro 11 Pre Delivery ProC Curre ccccsccsccecescnececcsenecnecsenscnecsenscnecsenecuecsenscneseusenecsenssneenenees 12 Delivery Proced re saias sie diciiss assassinas asa aab as ads And asno Eus S masa sad aidea canas 13 Joining Two Foundations siusicusissiiisncsnnssiacnmsnmensnnbanbaninsunswenvanuaeineinvakupkeabwosesieovenstastavauss 15 OPERATION Wired Remote Control Features ccccsccescescencenceeeceenenseenecnsensonsonsceecnsensonsensens 16 Operating INSIFUCHONS assa aasissis aiai aR inn E 17 SPECIAL FUNCTIONS Emergency Power Down isiaosisansianain gaia aaa li 18 Change from Tandem System to Single SySteM c ccccscsseeeesseeeessenseneeeseenseeeeeneeens 18 TROUBLESHOOTING quinas sadios i neon bs ii Ugo asus aii EEEa 19 Operating electronics and motors are UL approved SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Safety Precautions safety Pre
11. arrives ready to place within a standard bed frame The total height will vary based on your bed frame The height of the foundation alone is 9 inches IS IT POSSIBLE TO RAISE THE HEIGHT OF THE REFLEXION UP FOUNDATION Legs and or casters can be attached to the Reflexion UP Foundation by using leg brackets in conjunction with leg and or caster sets Brackets legs and casters are available for purchase from Sealy The leg height of the Reflexion UP Foundation ranges from approximately 3 1 4 to 11 See the chart on page 10 for available options DOES THE REFLEXION UP FOUNDATION COME WITH HEADBOARD OR FOOTBOARD ATTACHMENTS No you cannot attach a headboard or footboard directly to the Reflexion UP Foundation However you can use a freestanding bed including headboard footboard and side rails by placing the complete Reflexion UP Foundation within the assembled bed The Reflexion UP Foundation can be used in conjunction with bed slats You should measure the inside dimensions of the assembled bed to be sure the foundation will fit It may be easiest to assemble the bed around the foundation One of our riser leg sets may be required in some cases WILL THE REFLEXION UP FOUNDATION FIT INSIDE EXISTING FURNITURE The Reflexion UP Foundation is designed to fit into most freestanding beds We always recommend you measure the inside dimensions of the assembled bed to be sure the Reflexion UP Foundation will fit P
12. bor and transportation costs associated with the repair or replacement of any parts which Sealy determines to be defective This three 3 year warranty shall not apply if the purchaser does not return any and all defective parts to Sealy within 15 days of purchaser s receipt of such replacement parts furnished Return of the Base however should it need to be replaced is not required In no instance will this Warranty cover any damage attributable to misuse or to normal wear and tear or to excessive weight placed upon the product Nor will this Warranty cover any purchaser other than the original purchaser nor will it cover product purchased from an unauthorized third party If you are not the original purchaser of this product you take as is and with all faults If you did not purchase this Reflexion UP Foundation directly from Sealy we will require proof of purchase from you demonstrating that you are the original purchaser and are eligible to make a valid claim under this Warranty YEARS 4 THROUGH 5 FULL COVERAGE OF PARTS ONLY Upon notice during the years four 4 and five 5 from the warranty commencement date Sealy will offer replacement parts for any defective parts to the purchaser Factory supplied electronics electrical components drive motors and power supply components are included This two 2 year warranty shall not apply if purchaser does not return any and all defective parts to Sealy within 15 days of purcha
13. cautions Never operate the furnishing with the air openings blocked WAR N N G Keep the air openings free of lint hair and the like IMPORTANT SAFETY ie U U N ST R U CTI 0 N S E e Do not operate where aerosol spray products are a iam o ir ca INSTRUCTI O NS then remove a from outlet i THOROUGHLY BEFORE WARNING USI N G T H IS PRO D U CT Risk of Injury keep children away from extended SAVE TH ES E NSTRU CTI O NS head support or other similar parts The Reflexion UP Foundation has been designed to Never drop or insert any object into any opening provide you with the reliable operation and durability you expect This product has been inspected and tested prior to shipment When using an electrical furnishing basic precautions should always be followed including the following READ ALL INSTRUCTIONS BEFORE USING YOUR REFLEXION UP FOUNDATION DANGER To reduce the risk of electric shock e Always unplug this furnishing from the electrical outlet before cleaning WARNING To reduce the risk of burns fire electric shock or injury to persons e Unplug from outlet before putting on or taking off parts e Close supervision is necessary when this furnishing is used by or near children invalids or disabled persons Use this furnishing only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer e Never operate this furnishing if it has a
14. damage to the Reflexion UP Foundation always open the carton while the bed is in the flat position OPEN FLAT SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Delivery Procedure NOTE Always keep the Reflexion UP Foundation in a flat horizontal position during transportation and delivery Always open the box in the flat position STEP 1 Carefully take the foundation in the carton to the bedroom and place next to where the customer wants it set up STEP 2 Carefully lift the Reflexion UP Foundation out of the shipping carton keeping the unit topside down For safety reasons this should be performed by two people NOTE To avoid damage OPEN FLAT tothe foundation lt always open the carton while the bed is in the flat position STEP 3 The products come packed in a cardboard box Some components are also sealed in plastic film To unpack proceed as follows STEP 3A Remove the cardboard and plastic film from the components STEP 3B Check the package contents STEP 3C Dispose of the packaging materials STEP 3D Keep the user manual at hand for the operators Installation STEP 4 Remove the Wired Remote Control from the frame Verify the 2 9 Volt Batteries were installed into the battery compartment of the power supply NOTE Do not mix old and new batteries STEP 5 Connect the power cord from the power supply to the surge protector not included STEP 6 NOT
15. e Head section Press the HEAD UP button 1 STEP 2 Keep pressing the button until Lower the Mattress Retainer Bar to gain access to the desired height is reached the foot of the mattress Head Down 2 This function lowers the Head section to the desired position Press the HEAD DOWN button 2 Keep pressing the button until STEP 3 the desired height is reached After replacing the linens make sure the Mattress Retainer Bar is raised to the upright locked position EN AGG N A NS Pos ar TT OVAS ANA WAN lo fl j W NGC Flat 3 Press the FLAT button 3 and the bed frame will automatically move to its complete flat position NOTE Ensure all obstructions are clear of the foundation s undercarriage when lifting or lowering the foundation s head section to avoid NOTE Ensure that the Mattress Retainer Bar risk of pinching or damage is in the upright locked position to prevent mattress slippage during operation SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Special Functions EMERGENCY POWER DOWN The power down button on the power supply unit gives the user the ability to move the bed to a flat position during power failure SINGLE SYSTEM Press the Power Down button on the power supply until the bed arrives at the flat position After this procedure the two 2 9 Volt Batteries must be changed DANGER Risk of pinching NOTE During the emergency power down procedure
16. g in the A output of the Y Cable into Frame A control port Head STEP 5 Plug in the B output of the Y Cable into Frame B control port STEP 6 Plug one of the provided Wired Remote Controls into the Control Input side of the Y Cable SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Reflexion UP Foundation Wired Remote Control Features READ ADVISORY INFORMATION IN THE SAFETY PRECAUTIONS SECTION OF THIS GUIDE CAREFULLY BEFORE USING THIS PRODUCT THE POTENTIAL FOR ELECTRIC SHOCK EXISTS IF ELECTRICAL COMPONENTS ARE NOT INSTALLED OR OPERATED PROPERLY 1 HEAD UP HU 2 HEAD DOWN HD 3 FLAT F SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Operation Operating Instructions To ensure safe operation of the system please observe the following safety instructions CAUTION Keep children away from electrically adjustable beds and control units There is risk of injury and electric shock CAUTION Unplug the power cord during a thunderstorm or if you do not intend to use the system for an extended period of time NOTE Do not put the remote control button side down NOTE The actuators will continue moving until you release button or the maximum height is reached MANUAL ADJUSTMENT OF HEAD CHANGING LINENS Head Up 1 STEP 1 This function raises the Head Begin in the flat position If necessary use the FLAT section to the desired position button 3 to lower th
17. l purchaser nor will it cover product purchased from an unauthorized third party If you are not the original purchaser of this product you take as is and with all faults If you did not purchase this Sealy Reflexion UP Foundation directly from Sealy we will require proof of purchase from you demonstrating that you are the original purchaser and eligible to make a valid claim under this Warranty This Warranty does not include coverage for damage caused by the purchasers or by other users if the product has been used in a manner inconsistent with the operation and maintenance procedures outlined in the Complete Reference Guide this Warranty or any other applicable document published or approved by Sealy Nor does it include coverage if the product has been repaired or modified by the purchaser or by an unauthorized third party or if the product has been damaged in transit This warranty does not apply to damage to mattresses fabric cables electrical cords or items supplied by Resellers as defined below Contact the Reseller or other appropriate party for warranty information on these items Nor does this Warranty apply to any unnecessary service Calls including costs for in home service calls solely for the purpose of educating the consumer about the unit or finding an unsatisfactory power connection In addition if the recommended weight restrictions are not followed Twin Twin Long Double Queen and Split Dual CA King bases
18. lease refer to the specifications on page 10 for dimensions of the foundation One of our aftermarket riser leg sets may be required in some cases The Reflexion UP WHERE IS THE SERIAL NUMBER ON THE REFLEXION UP FOUNDATION The serial number can be found in two locations of the foundation on the back of the right side of the head section visible when the head section is raised and on the law tag attached to the foot section DOES THE UNIT HAVE AC OR DC MOTORS The lift motors used on the Reflexion UP Foundation are DC motors The foundation s power supply converts the AC power from the wall outlet to DC power WHO DO I CALL FOR SERVICE OR SUPPORT IF NEEDED Service and technical support are available by calling our dedicated customer service group at 1 800 499 1965 An owner s manual is included with each foundation including other information for making claims IS AN EXTENDED WARRANTY AVAILABLE No DO I GET A FULL WARRANTY IF PURCHASE A FLOOR MODEL Yes However your warranty start date is the date of manufacture which is clearly marked on the law tag attached to the foundation not your actual purchase date WHAT ARE THE ELECTRICAL REQUIREMENTS OF THE REFLEXION UP FOUNDATION During normal operation the foundation can draw up to 3 A of electricity from a normal AC wall outlet Foundation can be used in conjunction with bed slats SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Reflexion UP F
19. noise is heard under the bed when raising or lowering outlet A grounded electrical surge protection device is recommended Test the outlet by plugging in another working appliance Unplug the power cord wait 60 seconds and plug the power cord back in to reset the electronic components Your surge protection device and or electrical circuit breaker may be tripped Check both to verify Your surge protection device and or electrical outlet may be defective Test the outlet by plugging in another working appliance The Reflexion UP Foundation may be obstructed Elevate and check for an obstruction Remove the obstruction The head section may be too close to the wall Make sure that you are following the duty cycle of the motors do not operate more than 2 minutes over a 20 minute period or approximately 10 duty cycle Press the lift button squarely and accurately This is normal The lift motor relays click when they are engaged No action is required SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Manufacturing Site O04 O10 O 28 O 45 O 83 O 88 O 97 O 98 serial Number Write Serial Number here for future reference FOR TECHNICAL SUPPORT OR SERVICE QUESTIONS ABOUT YOUR SEALY MATTRESS OR TO ORDER REFLEXION UP FOUNDATION ACCESSORIES 1 800 499 1965 OR EMAIL CUSTOMERSUPPORTIASEALY COM 9220 TEM v11
20. oundation Bed Type A Foundation B Foundation Weight a o Width Length Specifications Twin 37 1 2 74 1 4 Twin Long 37 1 2 79 Double 53 1 4 75 Queen 58 1 4 79 Split CA King 35 3 4 82 3 4 7 Brackets are required to attach legs or casters and are available as aftermarket purchase 54 3 4 Measurements are approximate and based on 9 riser leg kit Legs and casters are optional and available as aftermarket purchases 9 Riser Leg with caster 41 2 Riser Leg without caster No Leg 41 2 Riser Leg 61 2 Riser Leg standard 6 1 2 Riser Leg 9 Riser Leg with caster without caster with caster without caster Caster Only C To Foundation 3 1 4 4 1 2 7 6 124 9 9 11 dos D To Mattress 12 1 4 13 1 2 16 15 3 4 18 18 20 1 2 SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Installation Installation Instructions Attached to foundation for shipping Appearance of some parts may differ from photos Before discarding any packing materials check the Reflexion UP Foundation carton and verify the following items in the parts list are included PARTS LIST A Wired Remote Control hard wired to bed 1 B Connection Y Cable 1 Only on Twin Long 9 and Split CA King Mattress Retainer Bar 1 Retainer Bar Plate 2 Retainer Bar Screw 2 71 MM O Oo 9 Volt Batteries 2 SEALY CUSTOMER SE
21. ser s receipt of replacement part Purchaser shall bear all service transportation labor and shipping costs related to the delivery and or replacement of the defective part BASE ONLY YEARS 1 THROUGH 15 WARRANTY Notwithstanding the above Sealy extends a 15 Year Warranty on the Base itself used in this product Specifically Sealy warrants that for a full 15 years any defect in the workmanship or the materials used in the Base itself shall be covered The 15 year time span will be dated from the commencement of this Warranty For purposes of this 15 Year Warranty the Base consists of the wooden and metal structure of the Foundation and specifically excludes its cover decking and legs actuator lift motors control box remote controls power supply and any power supply cords Return of the Base should it need to be replaced is not required A proper bed frame must provide sturdy support for both the mattress and foundation Sealy highly recommends either i leg accessories designed for Reflexion UP Foundation provided by Sealy at an additional cost ii a3 bed beam support system provided by Sealy at an additional cost OR iii a Support system of similar quality that is designed specifically to give slatted style bed frames additional structural support For slatted style bed frames it is incumbent upon purchaser to ensure that the frame utilized offers ample structural support for that particular slatted style frame
22. the lowering speed will be reduced NOTE Do not mix old and new batteries TANDEM OPERATION Each foundation must be moved to the flat position separately by following the single system instructions After this procedure the two 2 9 Volt Batteries of both power supplies must be changed NOTE Do not mix old and new batteries Reflexion UP Foundation CHANGE FROM A TANDEM SYSTEM TO A SINGLE SYSTEM STEP 1 Disconnect both foundations from wall outlet STEP 2 Remove connections for Y Cable from each control port NOTE Store Y Cable in a safe place for future use NOTE Locate spare Wired Remote Control from storage for use on second base STEP 3 Reconnect Wired Remote Control cable to the control port of each base SEALY CUSTOMER SERVICE DEPARTMENT 1 800 499 1965 Special Functions and Troubleshooting Troubleshooting In the event that the Reflexion UP Foundation fails to operate properly investigate the symptoms and possible solutions provided in the chart below SYMPTOM SOLUTION Wired Remote Control backlit LED e Verify that the power cord is plugged into a working electrical illuminates and appears to be operable but will not activate the Reflexion UP Foundation No features of the Reflexion UP Foundation will activate Head section will elevate but will not return to the horizontal Flat position Head lift function has minor interference during operation A clicking
23. tive parts under this Limited Warranty shall be made by Sealy at its option and at its sole discretion Except for the Warranty provided for the frame of this product there is no warranty at all after five years dating from commencement of this Limited Warranty SEALY SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRANTY THE EXCLUSIVE REMEDY FOR BREACH OF THIS WARRANTY SHALL BE REPLACEMENT OR CREDIT TOWARDS REPLACEMENT AS SET FORTH HEREIN THERE ARE NO EXPRESS OR IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY DESCRIBED ON THE FACE OF THIS LIMITED WARRANTY Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to every purchaser This warranty gives the purchaser specific legal rights and the purchaser may also have other legal rights which may vary from state to state This Warranty is valid in all 50 states Puerto Rico and Canada If you the purchaser experience any problem with your Reflexion UP Foundation during the Warranty period please consult the troubleshooting section of your Reference Guide If the problem persists please contact Sealy s Customer Service Department by calling toll free 1 800 499 1965 or by sending an email to customersupport sealy com PLEASE RE
24. will not roll they may slide USER SERVICEABLE PARTS This product is specifically designed to be maintenance free for the user Therefore you are encouraged not to open any motors alter the wiring or adjust modify or change the structure of the product as it will void the warranty POWER RATINGS MODEL NO 609440 609439 INPUT AC 120V VAC 60 HZ 3 A MAX OUTPUT DC 24V 1 5A CONTROL ACTUATOR 1 Safety Precautions SMALL CHILDREN AND PETS WARNING After the Reflexion UP Foundation has been unboxed immediately dispose of packaging as it can smother small children and pets To avoid injury children and pets should not be allowed to play on or under the bed Children should not operate this product without adult supervision Close supervision is necessary when this furnishing is used by or near children invalids or disabled persons SAVE THESE INSTRUCTIONS Your Reflexion UP Foundation has been designed to provide you with the reliable operation and durability you expect This product has been inspected and tested prior to shipment SERVICE REQUIREMENTS Service technicians are not responsible for moving furniture removing headboards and footboards or any items required to perform maintenance on your Reflexion UP Foundation In the event the technician is unable to perform service due to lack of accessibility the service call will be billed to the purchaser and the service will be re scheduled SEALY CUSTOME

Download Pdf Manuals

image

Related Search

Related Contents

manuel de l´utilisateur      Presentación de PowerPoint  Samsung ATIV XE700T1C  GH-PM 51 S HW-E - Einhell Germany AG  WIRELESS 150N USB ADAPTER QUICK INSTALL GUIDE  

Copyright © All rights reserved.
Failed to retrieve file