Home

PROLITE-30B user manual (optical fibre identifier)

image

Contents

1. Connect AC power cord with the equipment and wall socket properly While inserting the AC plug make sure there is no dust or dirt on the terminals and both plugs are fully seated Incomplete engagement may cause fuming electric shock or equipment damage and may result in personal injury Do not operate the equipment near hot objects in hot environments in dusty humid atmosphere or when condensation is present on the equipment This may result in electric shock product malfunction or poor performance ZXPROMAX PROLITE 30B 3 Preparing for Operation 3 1 Unpacking the instrument Packing material We suggest that you keep the original packing material Using the original packing material is your guarantee of protecting the instrument during transit Checking the package contents The standard accessories of PROLITE S3OB are as follows gt Main unit gt User s Guide gt Plungers gt 2x 1 5 V Alkaline Batteries gt Carrying Case Checking for damage in transit After unpacking the instrument check to see whether it was damaged in transit This is particularly likely if the outer casing is clearly damaged If there is damage do not attempt to operate the instrument or to repair it without authorization Doing so can cause further damage and you may lose your warranty qualification ZXPROMAX PROLITE 30B 3 2 Battery The PROLITE S3SOB instrument is powered by two 1 5 V AA batteries There is a Low ba
2. OPTICAL INSTRUMENTS SERIES User s Guide to the PROLITE 30B Optical Fiber Identifier eee Det araon APROMAX Depot Melrose MA 02176 AA PROMAX Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431 v1 0 0 MI2027 02 12 2014 mAN NENP O AXPROMAX PROLITE 30B 1 Introduction The PROLITE S3OB optical fiber identifier is an inexpensive portable instrument designed to identify optical test tones and live traffic without disconnecting live system By simply clamping the PROLITE S3OB onto a fiber the instrument will indicate if there is a signal or traffic and show the signal direction It can detect a variety of optical tones 270 Hz 1 kHz and 2 kHz The PROLITE 3OB is recommended for both 0 25 mm bare fiber 0 9 mm tightly buffered fiber and 2 3 mm jacket fiber When testing jacket fibers the slim design of the PROLITE 30B allows easier access to a splice tray where the amount of workspace is limited The clamping trigger is designed to fit the natural motion of the operator s hand The instrument is ruggedly constructed and reliable to use ZXPROMAX PROLITE 20B 2 Safety Information Warnings e Never look directly into optical outputs or a fiber while the equipment is on Invisible laser beam may damage your eyes Do not short circuit the terminal of AC adapter charger and the batteries Excessive electrical current may cause personal injury due to fumes electric shock or equipment damage
3. l intensity indicator on the panel board lights up to tell you how strong the signal is There are 5 LEDS aligning in a line More of them illuminate meaning the signal is stronger 11 AXPROMAX PROLITE 30B 5 6 Self calibrating The instrument may need a little adjustment after long term disuse or a sudden change of the environment such as temperature or light variation Change the plunger to the H0 25 type pull the clamping trigger then press the Adjust key shortly to start the self calibration which lasts about 10 30 seconds When it finishes the instrument makes a buzzing sound and the No Signal Indicator blinks 12 AXSPROMAX PROLITE 30B 5 Specifications Optical Specifications Model PROLITE 30OB Recognizable Wavelength Range 900 nm 1650 nm Recognizable Signal Type CW 270 Hz 5 1 kHz 5 2 kHz 5 Detector Type InGaAs H 0 25 for bare fibers Available Plunger H 0 9 for tightly buffered fibers H3 0 for jacket fibers Detecting Sensitivity lt 50 dBm Power 2x1 5V AA batteries Sensitivity Minimum recognizable optical power intensity in the fiber 1310 nm typical 1550 nm typical Continuous Wave 20 dBm 30 dBm 2 kHz Modulated Wave Detection 10 dBm 18 dBm 1 kHz Modulated Wave Detection 10 dBm 18 dBm 270 Hz Modulated Wave Detection Operation Temperature 10 C 50 C Storage Temperature 20 C 70 C Size HxWxD 3 6 c
4. m x 6 2 cm x 20 2 cm Weight 0 27 kg 13 ZXPROMAX PROLITE 30B 6 Maintenance 1 All the specifications of PROLITE 3OB series are tested with cleaned Corning SMF 28TM SMF D pure non dispersion coated fiber The testing performance will be affected when using different brands or types of fibers with various coating color 2 Please do not bend the fiber excessively which may lead to misjudgment on traffic or even breaking the fiber 15 ZXPROMAX PROLITE 30B 3 Keep the optical receiver clean and use cleaning oil when testing bare fiber to achieve the best performance 4 To clean the optical assembly remove the clamp and gently clean the prism and optical windows using cleaning pads and cleaning oil Do not immerse the plunger assembly in alcohol Removing the clamp before cleaning Cleaning pad Cleaning oil 16 PROMAX ELECTRONICA S L Test Equipment 99 Washington Street Depot Melrose MA 02176 Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431
5. ttery indicator on the panel board It turns on if there is not enough power to supply the instrument That is when you should replace the battery with a new one To replace the battery please remove the battery plate on the back side of the instrument with a screwdriver Note 1 It is advisable to use 1 5 V alkaline batteries The Low Battery Indicator may light up if you use rechargeable batteries 2 To eliminate the possibility of acid leakage please take out the batteries if the unit is not used for a long time x PROMAX PROLITE 30B 4 Operation 4 1 Controls and connectors 4 1 1 Front Panel Board No Key Indicator Description 1 Plunger Three available types H0 25 mm H0 9 mm H3 0 mm 2 Fiber Groove A slot to place tested fiber 3 PD Headstock 4 No Signal Indicator Lights up if there is not a signal in tested fiber 5 Left Traffic Indicator Lights up if the signal in tested fiber is from right to left 6 Right Traffic Indicator Lights up if the signal in tested fiber is from left to right 7 Signal Intensity To show the signal intensity level The higher the stronger Indicator 8 2 kHz Indicator Lights up if the wave frequency is 2 kHz 9 1kHz Indicator Lights up if the wave frequency is 1 kHz 10 270 Hz Indicator Lights up if the wave frequency is 270 Hz 11 Low Battery Indicator Lights up when there is not enough power 12 Adjusting Ke
6. y Self calibrates ZXPROMAX PROLITE 30B 4 1 2 Back amp Side 1 Serial Number 2 Clamping Trigger 3 Battery Plate AXPROMAX PROLITE 30B 4 2 Powering on the instrument Gently insert the tested fiber into the groove at the top of instrument Pull the clamping trigger slowly to depress the fiber against the optical assembly The instrument powers on when the detector plunger has closed and the fiber is in the appropriate position Note Please be careful while placing the fiber in the provided slot Force the fiber into the headstock Misaligning the fiber may induce optical losses above what the specification demonstrates ZXPROMAX PROLITE 30B 4 3 Traffic detecting If the tested fiber is carrying signal a Traffic Indicator illuminates to show the direction left or right When no signal is present or the signal to be tested is too weak for the instrument to detect the No Signal Indicator illuminates ZXPROMAX PROLITE 30B 5 4 Frequency detecting If the tested fiber is carrying 2 kHz 1 kHz or 270 Hz modulated wave the respective modulation indicator illuminates and the instrument makes a buzzing sound Note The instrument may not recognize the frequency correctly if the signal is too weak or the frequency is not stable 10 ZXPROMAX PROLITE 230B 5 5 Signal intensity The signa