1. ormpn s300 Page 8 of 9 Products manufactured by TPI Corporation are warranted to the original consumer to be free from defects in material and workmanship for twelve 12 months from the original purchase date The TPI limited warranty does not cover products that have been modified outside of our factory damage or failure caused by acts of God abuse misuse connected to or placed on other than rated voltage abnormal usage fault installation failure to follow suggested maintenance procedures enclosed with the product improper maintenance or any repairs other than those provided by an authorized TPI service center There are no obligations or liabilities on the part of the Corporation for consequential damages arising out of or in connection with the use or performance of the product or other indirect damages with respect to loss of property revenues profit costs of removal installation or reinstallation All implied warranties with respect to TPI products including implied warranties for merchantability and implied warranties for fitness are limited in duration to twelve 12 months from original date of purchase except those products or parts of products which are warranted for long periods thereon Some states do not allow the exclusions or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts The above exclusions or limitations may not apply to you
2. 10 32 x YY Screws Figure 4 optional mounting view orpmpn s300 Page 5 of 9 WIRING INTERNAL WIRING DIAGRAM CH heaters are equipped with two Hli temperature ELECTRICAL SHOCK silicone lead wires and a bonding ground HAZARD termination Serious injury or death may occur Disconnect from electrical Heater Housing supply before installing or J servicing this heater Read and follow all safety Quartz Lamp information in box below conforms to specifications on the Make certain the power source heater label Hi temp wires Cordset Do not depend on a thermostat or other switch as the sole means of disconnecting power when installing or servicing heater Always unplug the cordset or open the safety switch and lock it open Bonding is the term that describes the completion of the electrical circuit back to its source which allows a breaker or fuse to clear if a short occurs 1n the line All wiring must be performed by a licensed electrician The cordsets supplied with these heaters are equipped with provisions for proper bonding grounding Always mate the cordset plug with the proper bonded grounded receptacle in accordance with the National Electric Code and all governing local codes and ordinances Do not use an extension cord to provide power to these heaters Never connect the green or green yellow wire to a live or hot conductor Issue
3. A 6 15P__ 6 15P NEMA 6 15R 6 15R Mounting Bracket CH MB Model P N Tube PN Watts Volts Amps Cordset DimA DimB DimC CH 46C 04860002 04432302 1500 120 12 5 YES 42 0 5 375 6 500 CH 57C 04860102 04414702 3000 240 12 5 YES 53 0 5 375 6 500 6FT CORDSET EXITS OPTIONAL MOUNTING END OF HEATER BRACKET SHOWN NOT SHOWN Rot i M o Issue Date 08 27 07 Rev Date12 16 09 Rev Level 09 ECO 1 6239 oiPMP N 8306 Page 3 of 9 QUARTZ TUBE INSTALLATION Each heater is equipped with two hi temperature silicone lead wires and a ground termination Make sure power source conforms to the heater requirements Use only Fostoria ELECTRICAL SHOCK quartz tubes HAZARD 1 Insert quartz tube in the L shaped slots in heater housing 2 On each end of the quartz tube place 1 lead wire ring Serious injury or death terminal 1 lock washer and 1 hex nut on the threaded may occur stud and tighten securely see image below Lock washers and hex nuts are provided in hardware package Disconnect from electrical NOTE Use a second wrench to hold the inner hex nut in supply before installing or place while tightening the outer hex nut Failure to servicing this heater securely tighten this connection will cause the element to fail prematurely Reflector end caps must be installed prior to powering QUARTZ TUBE i HEX NUT the unit refer to note 3 N LOCK WASHER Install heater so that the quartz tubes are h
4. CH Series COMFORT HEATERS for INDOOR and Semi1 Protected OUTDOOR USE EXCLUDING RESIDENCES COVERED APPLICATIONS REFER TO COMPLETE INDEX OF IMPORTANT SAFETY INFORMATION INSIDE INFORMATION ON Serious injury or death possible PA GE 2 Read understand and follow all safety information and instructions in this manual before using or servicing this product Retain these instructions for future reference Issue Date 08 27 07 Rev Date12 16 09 Rev Level 09 ECO1 6239 OIPMPIN 8306 Page 1 of 9 Issue Date 08 27 07 INDEX Index Safety Signal Word Definitions Specifications Quartz Tube Installation Heater Installation Wiring Replacement Parts Maintenance Troubleshooting Warranty ATTENTION The table to the right provides definitions of the signal words that can be found throughout this manual These signal words are used to express the severity of the hazard at hand The signal words are generally used in conjunction with safety symbols that correspond to the text for that particular hazard As you read this manual refer back to this table when you are unsure of the signal word definition Rev Date12 16 09 Rev Level 09 ECO 1 6239 Page 2 Page 2 Page 3 Page 4 Pages 4 amp 5 Page 6 Page 7 Page 8 Page 8 Page 8 AHAL WIRD DEFINITIONS ADANGER OIPM P N DANGER indicates animminently hazardous situation which if not avoided will rest in death or serious injury WARHIHG
5. Date 08 27 07 Rev Date12 16 09 Rev Level 09 ECO 1 6239 OIPM P N 8306 Page 6 of 9 REPLACEMENT PARTS LIST CH 46C CH 57C ITEM QTY PART NO PART NO DESCRIPTION 08561801 08560401 REFLECTOR 2 2 08561201 REFLECTOR END CAP 4 1858 SCREW 8 32 X 3 8 04432302 04414702 QUARTZ TUBE 3440300 CHAIN KIT Issue Date 08 27 07 Rev Date12 16 09 Rev Level 09 ECO 1 6239 oiPMP N 8306 Page 7 of 9 MAINTENANCE 1 Always disconnect heater from power supply before performing any maintenance or service 2 Periodically clean dampened soft cloth using mild detergent Rinse with water and wipe dry with a clean soft cloth Element does not energize Not enough heat Too much heat Hot spot in tube Issue Date 08 27 07 Rev Date12 16 09 Rev Level 09 ECO 1 6239 with a Defective element Improper connection Heater too small for application Heater mounted too high or too far Heater too large for application Heater mounted too low or too close Heater is not level Grease or moisture on tube LIMITED WARRANTY ELECTRICAL SHOCK HAZARD Serious injury or death may occur Disconnect from electrical supply before installing or servicing this heater Replace element Check connection to power outlet Add additional heater s Decrease mounting height or distance Replace with smaller heater Increase mounting height or distance Adjust to a level mount Clean tube replace if problem persists
6. During the warranty period TPI Corporation will at its sole option repair or replace any defective parts or products returned freight prepaid to the TPI Corporation factory or such other locations as TPI Corporation may designate Returned products must be packaged carefully and TPI Corporation shall not be responsible for damage in transit When returning parts the owner must provide the model number of the product and nature of difficulty being experienced This warranty does not obligate TPI Corporation to bear the cost of labor in replacing any assembly unit or component part thereof nor does the company assume any liability for secondary charges expenses for installing or removal freight or damages There will be charges rendered for product repairs made after the warranty period has expired Proof of purchase including date must accompany request for in warranty service In any event TPI Corporation s maximum liability shall not in any case exceed the list price for the product claimed to be defective This warranty gives to you specific legal rights and you may have other rights which may vary from state to state For the name of your nearest authorized TPI Corporation service center please write to TPI Corporation P O Box 4973 Johnson City TN 37602 HEATING PRODUCTS WARRANTY COVERAGE Heating Products Elements in 10 Years Baseboards 1 Year All other Heating Products 2 Years Thermostats and Controls VENTILATION PRODUCTS WARRAN
7. TY COVERAGE Series HD or HDH Fans Series UHP or IHP Fans All other Ventilation Products Issue Date 08 27 07 Rev Date12 16 09 Rev Level 09 ECO1 6239 oiPMP N 8306 Page 9 of 9
8. cture Crimp S hooks closed after assembly Optional Bracket Mounting Kit CH MB p n 04863802 As an option you can mount your heater with two adjustable mounting brackets and fastening hardware Using the mounting centers specified in figures 2 amp 3 mount your adjustable mounting brackets bends to the inside Once mounted assemble the heater to brackets with mounting hardware these brackets enable the heater to be angled in 15 degree increments up to 45 degrees This kit includes two adjustable brackets four 10 32 x 1 2 screws and four 10 32 keps nuts CAUTION Install heater so that the quartz tubes are horizontal Failure to do this may cause the heating element within the tube to sag and cause premature burnout ELECTRICAL SHOCK HAZARD Serious injury or death may occur Disconnect from electrical supply before installing or servicing this heater Read and follow installation clearance requirements on page 4 Issue Date 08 27 07 Rev Date12 16 09 Rev Level 09 ECO 1 6239 STANDARD MOUNTING ADS OPTIONAL BRACKET MOUNTING Optional mounting brackets a O00 a Figure 1 end view 6 500 sars Figure 2 end view CH 46C 41 0 _ CH 57C 52 0 I GHaG dap CH57 530 Figure 3 side view 10 32 Nylon Mountin g Keps Nut A Bracket a
9. indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION inckcates a potentially hazardous situation which if not avoided may result in minor or moderate irqury CAUTION used without the safety alert sym bol ind cates a potentially hazardous situation which if not avoided may result in property cam ag As defined in AN Gl 2935 4 2002 s06 Page 2 of 9 SPECIFICATIONS DESCRIPTION Fostoria multi purpose CH series electric infrared EXPLOSION HAZARD heaters are designed to provide efficient spot heating FIRE HAZARD for many commercial and industrial applications All models operate with a single quartz tube emitter included with the heater are easily installed and are equipped with spectral reflectors for excellent radiant output They are built with corrosion resistant materials and are for INDOOR and Semi Protected OUTDOOR applications in the USA and Canada When used outdoors they should be installed under a canopy or other similar type installation that is semi protected e Serious injury or death may occur Do not use in locations containing hazardous atmospheres Do not use as a residential or household heater SPECIFICATIONS Housing 24 ga Galvannealed l a Voltage Cordset Plugs Matching Finish Hi temp brown powder coat Receptacle Reflectors end 0 040 gold anodized aluminum 0V ST ar ce caps be eee Chain or Optional Adjustment 240V NEM
10. orizontal Failure to do this may cause the heating element within the tube to sag and cause premature burnout RING TERMINAL 3 Attach reflector end caps to both ends of housing using the 4 screws provided in hardware package HEATER INSTALLATION MINIMUM INSTALLATION CLEARANCES These heaters MUST be installed as follows FIRE HAZARD gt CH 46C Serious injury or death may o 12 inches min from a vertical surface occur gt CH 57C Read and follow clearances o 24 inches min from a vertical surface shown in box at left for ALL CH series heater installations 72 inches minimum from ANY combustible material a Do not use inside residences 3 inches minimum from the ceiling 36 inches minimum from other heaters NOTE For optimum spot heating performance it is recommended that the distance from the floor should be approximately 7 to 9 feet for CH 46 models and 8 to 10 feet for CH 57 models Issue Date 08 27 07 Rev Date12 16 09 Rev Level 09 ECO 1 6239 OIPMP N 8306 Page 4 of 9 HEATER INSTALLATION continued SUSPENSION ALTERNATIVES Your CH series heater can be mounted with either the standard chain suspension or optional CH MB p n 04863802 adjustable mounting bracket kit Standard Mounting The heater is to be chain hung as shown in figure 1 Cut the 16ga chains two 4 foot chains are provided to desired length Attach chains to heater with S hooks provided and suspend from overhead stru