1. With no load the values of voltage and frequency are usually superior to their rated values about 10 for vol tage and 5 for frequency When the power increases with inserted loads the voltage and frequency values diminish at full power the voltage can be reduced of 10 and the frequncy of 3 Before the use check that the electrical specifications for the units to be powered voltage power frequency are compatible with those of the generator Values that are too high or too low for voltage and frequency can damage electrical equipment irreparably In some cases for the powering of three phase loads it is necessary to ensure that the cyclic direction of the phases corresponds to the installation s requirements GFI The GFI D at higt sensitiveness 30 mA guarantees the protection against indi rect contacts caused by faulty currents towards ground When the divice notes a faulty current at the ground superior to 30 mA it breaks the feeding at the a c sockets In case of intervention check that there is no isolation fault in the plant of union cables sockets and plugs inserted tools Before each work session check the GFI device efficiency pressing the test key The generating set must be working and the GFI lever in ON position TS 200 DES EL TS 200 LDES EL The GFI does not work correctly without grounding of the unit Before use dispose an efficient grounding system using the PE terminal 12 and kee
2. 3 n table 5 MIS AR TWOLARICANBI SPARE PARTS PIECES DE RECHANGE ERSATZTEILE au T EA 30 10 1 3 13 18 17 16 20 21 22 o multu 21 22 23 ABBREVIATIONS AND SYMBOLS EV When ordering specify the engine type and the auxiliary voltage ER Engine with recoil starter only ES Engine with electric starter only VE E A S version only QM When ordering specify the length in meters VS Special version only SR By request only 14 12 986Q16M31 22 03 00 R1GB MOSA REV 2 11 11 CD Ricambi 9 Ersatzteile Spare parts CE Tabla de ricambios Pi ces de rechange TS 200 DES EL TS 200 LDES EL 26 05 05 27292 l MOSA REV 4 11 11 Pos cO O 00 N Sa n5 Cod 272506010 105311370 107011280 105913045 1018100 372803025 372853025 232123040 222401035 272722200 256862200 256762200 256842200 208014100 232123030 1001030 307012037 105112020 105111290 105311380 356403038 232123036 208015100 208015041 272708205 272701050 155307107 1302040 256027060 107302460 256022275 256027059 256047102 CD Ricambi 9 Ersatzteile Spare parts CE Tabla de ricambios CE Pi ces de rechange Descr CONVOGLIATORE ARIA AIR DUCT DISTANZIALE SPACER TIRANTE TIE ROD FLANGIA PORTAALTERNATORE FLANGE ALTERNATOR HOLDER ANELLO OR OR RING STATORE STATOR STATORE STATOR FLANGIA ATTACCO MOTORE FLANGE FIXING ENGINE ANTIVIBRANTE VIBRATION DAMPER M
3. Dimensions and weight are inclusive of all parts without wheels and towbar CTM POWER Declared power according to ISO 3046 1 temperature 25 C 30 relative humidity altitude 100 m above sea level It s admitted overload of 10 each hour every 12 h In an approximative way one reduces of 1 every 100 m altitude and of 2 5 for every 5 C above 25 C ACOUSTIC POWER LEVEL ATTENTION The concrete risk due to the machine depends on the conditions in which it is used Therefore it is up to the end user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions for instance adopting a I P D Individual Protection Device Acoustic Noise Level LWA Measure Unit dB A it stands for acoustic noise released in a certain delay of time This is not submitted to the distance of measurement Acoustic Pressure Lp Measure Unit dB A it measures the pressure originated by sound waves emission Its value changes in proportion to the distance of measurement The here below table shows examples of acoustic pressure Lp at different distances from a machine with Acoustic Noise Level LWA of 95 dB A Lp a 1 meter 95 dB A 8 dB A 87 dB A Lp a 7 meters 95 dB A 25 dB A 70 dB A Lp a 4 meters 95 dB A 20 dB A 75 dB A Lp a 10 meters 95 dB A 28 dB A 67 dB A PLEASE NOTE the symbol E when with acoustic noise values indicates that the device respects noise emission
4. power from other exits Drawing power from different exits their sum cannot go over the maximum power declared on data plate gene rally the three phase power SIMULTANEOUS USE The welder s alternator permits the simultaneous use of auxiliary power and welding current The auxiliary power available to the AC plugs 15 diminishes as the welding current drawn increases The table on page M1 6 TECHNICAL SPECIFICATIONS shows the amount of auxiliary power available as the welding current varies AOO eo N O 30 11 06 272 ACCESSORY USE REMOTE CONTROL 1C2 TC2 50 P lt I 4 6 C Jn inc gt L _ di i 5 CH _ l 1 N Ca LJ _ E E E Bee Y PUSH AND SCREW TIGHT The remote control device for regulating the welding current is connected to the front panel by means of a multipole connector To regulate the current from the TC2 TC2 50 move the switch 7 located above the multipole connector 8 to ON position Position welding current adjusting T knob at the necessary current value for the diameter and type of electrode 09 11 99 M38GB D OSA Engine protection REV 1 04 07 CF The warning lamps brighten by turning the engine starting key Q1 and they switch off after some seconds The engine protection in case of low oil pressure is shown by the warning light 01 without th
5. 59 ad 00l 000 de PIE r d 3 A n O E e Z e ke ta O E ooo 2 o Z L ELE pj 959 A SES ond PE o i efe ro nua DI An FR L 986 i E Assis I I I MOSA REV 1 04 07 1 90 90 92 QUOIZEZZIJO NE ens ezues 19 e o Ip 19 uoo oubasip ajuasaid jap ejatudoud e 9069 IP Lat e 95 IS YSOW 8 S9 S307 009 39 lt FP y esow WWWJ dyu H pe oJddy A Jaubiseq GUIDEN Ku ATWLI IIA O9VSNI 06002 BEEM oyeaouddy USI asopeubasig euidooe A e z Sid ye9sz Ov C1 S tupiequo1 aufualC gt V v aUo ueDeg 3oeloud uoneunwouag abed uo Ulp uBeg onabold auolzeuiwous Bed eq Iddy aeq UOIJea pon dx3 die ds3 TS 200 LDES EL 31 9H 9 I l O i KEE 4 ci A ag vr ag loca L I O XN NAE o _ L O go ce ES c V Lu 9 N 9 Rem 9 E 7 O D o Y L po o cM E p KE I E nan 7 I 310 1 a PS m NO I I i I E S oO D G o E o o ul lt gt T 2 gt LU TS 200 DES EL TS 200 LDES EL E O Ran fei O O E T 5 O o LLI c amp C tj S E O pem de V Y fei o vV E X V REV 1 04 07 D Schema elettr
6. Do not use without protective devices provided Removing or disabling protective devices on the machine is prohibited Do not use the machine if it is not in good technical condition The machine must be in good working order before being used Defects especially those which regard the safety of the machine must be repaired before using the machine SYMBOLS AND SAFETY PRECAUTIONS GE MS_ TS_ SAFETY PRECAUTIONS N DANGEROUS This heading warns of an immediate danger for persons as well for things Not following the advice can result in serious injury or death N WARNING This heading warns of situations which could result in injury for persons or damage to things N CAUTION To this advice can appear a danger for persons as well as for things for which can appear situations bringing material damage to things N IMPORTANT NOTE ATTENTION These headings refer to information which will assis you in the correct use of the machine and or accessories 26 11 99 M2GB D MOSA REV 2 06 10 o lt CJ O o STOP Read absolutely and be duly attentive Read and pay due attention GENERAL ADVICE lf the advice is not respected damage can happen to persons or things HIGH VOLTAGE Attention High Voltage There can be parts in voltage dangerous to touch The non observance of the advice implies life danger FIRE Danger of flame or fire If the advice is not respected fires can happen
7. PB3 PREPARING THE UNIT STARTING AND STOPPING THE ENGINE CONTROLS USE AS WELDER USING THE GENERATOR ENGINE PROTECTION ENGINE PROTECTION ES EV TROUBLESHOOTING MAINTENANCE STORAGE CUST OFF RECOMMENDED ELECTRODES ELECTRICAL SYSTEM LEGENDE ELECTRICAL SYSTEM SPARE PARTS LIST SPARE PARTS 30 11 06 27292 GB MOSA lt MOSA 1 0 10 02 N ATTENTION This use and maintenance manual is an important part of the machines in question The assistance and maintenance personel must keep said manual at disposal as well as that for the engine and alternator if the machine is synchronous and all other documentation about the machine GB Copyright CE We advise you to pay attention to the pages concerning the security see page M1 1 MOSA O All rights are reserved to said Company It is a property logo of MOSA division of B C S S p A All other possible logos contained in the documentation are registered by the respective owners The reproduction and total or partial use in any form and or with any means of the documentation is allowed to nobody without a written permission by MOSA division of B C S S p A To this aim is reminded the protection of the author s right and the rights connected to the creation and design for communication as provided by the laws in force in the matter In no case MOSA division of B C S S p A will be held responsible for any damaga direct or indirect in relati
8. Q1 don t ancharge the battery turning it counter clockwise OFF posi tion then take it out Shut the fuel cock ts NB for safety reason the key must be kept by qualified personel RUNNING IN During the first 50 hours of operation do not use more than 60 of the maximum output power of the unit and check the oil level frequently in any case please stick to the rules given in the engine use manual 0030 en Ej 30 11 06 27292 STARTING AND STOPPING THE ENGINE TS 200 LDES EL ELECTRIC STARTING check daily E Do not alter the primary conditions of regulation and do not touch the sealed parts Turn the starter key to the START position Once the engine has started let the key return to the ON position OFF SS ON ON START Let the engine run for some minutes before drawing the load s n case of unsuccessful start up do not insist for longer than 5 seconds Wait 10 seconds before attempting another start up EMERGY STARTING with starting handle 1 hold the starting handle pro perly 2 pull the starting handle slowly until you feel resistance 4 pull the rope hard and fast Pull it all the way out Use two hands if necessary ATTENTION If battery is not connected disconnect voltage re gulator to prevent damage STOP THE ENGINE r Before stopping the engine it is compulsory to stop the load shut off any loads which are c
9. d marrage Mando manual arranque Interruttore differenziale 30mA G F Interrupteur diff rentiel Interruptor diferencial 30 mA Fusibile Fuse Fusible Fusible Spia luminosa corrente alternata A C output indicator Voyants tension alternative Indicadores luminosos c alter Contaore Hour counter Compte heures Cuentahoras Regolatore corrente di saldatura Welding current regulator R gulateur courant soudage Regulador corr de soldadura Spia carica batteria Battery charge warning light Voyant charge batterie Piloto carga bateria Spia lumin press olio oil alert Oil press warning light oil alert Voyant lumin press huile oil alert Indic lum pres aceite oil alert Chiave di avviamento Starter key Cl de d marrage Llave de arranque Batteria Battery Batterie Bater a Interruttore comando a distanza Remote control switch Commutateur t l commande Interruptor mando a distancia Presa per comando a distanza Remote control socket Prise pour t l commande Toma para mando a distancia 26 05 05 27292 l USE AS A WELDER TS 200 DES EL TS 200 LDES EL This symbol Norm EN 60974 1 security standards for arc welders signifies that the welder can be used in areas with increased risk of electrical shock Areas for which access by non authorized person nel is forbidden are the control panel at the front the endothermic motor discharge the welding process CONNECT WELDING CABLES Insert the welding cable plugs comp
10. driven welders and generating sets Data Emissione corrente Data di scadenza Current issue Expiring date 19 10 2010 05 03 2012 Je oy LOM SPAS First issue 30 05 1994 S ACCREDIA S The advantages for MOSA clients are Constant quality of products and services at thehigh level which the client expects Continuous efforts to improve the products andtheir performance at competitive conditions Competent support in the solution of problems Information and training in the correct applicatio nand use of the products to assure the security ofthe operator and protect the environment Regular inspections by ICIM to confirm that the requirements of the company s quality systemand ISO 9001 are being respected All these advantages are guaranteed by the CER TIFICATE OF QUALITY SYSTEM No 0192 issued by ICIM S p A Milano Italy www icim it 10 10 02 M01 GB M 01 M 1 01 M 1 1 M 1 4 M 1 4 1 M 1 5 M 1 6 M 2 M 2 5 M 2 6 M 2 7 M 3 M 4 1 M 6 1 M 20 M 21 M 31 M 34 M 37 M 38 M 39 6 M 40 M 43 M 45 M 46 M 55 M 60 M 61 R 1 DR TS 200 DES EL TS 200 LDES EL QUALITY SYSTEM COPYRIGHT NOTES CE MARK DECLARATION OF CONFORMITY TECHNICAL DATA TECHNICAL DATA SYMBOLS AND SAFETY PRECAUTIONS INSTALLATION AND ADVICE BEFORE USE INSTALLATION AND ADVICE INSTALLATION AND DIMENSIONS UNPACKING TRANSPORT AND DISPLACEMENTS COVERED UNITS ASSEMBLY CTM 6 2
11. motore Engine oil reservoir cap Bouchon remplissage huile moteur Tap n llenado aceite motor Tappo serbatoio Fuel tank cap Bouchon r servoir Tap n dep sito Silenziatore di scarico Muffler Silencieux d chappement Silenciador de descarga Comando stop Stop control Commande stop Mando stop Tappo scarico olio motore Oil drain tap Bouchon d charge huile moteur Tap n vaciado aceite motor Protezione termica corrente aux Aux current thermal switch Protection thermique courant aux Protecci n t rmica corr aux Comando manuale avviamento Starting push button Commande manuelle d marrage Mando manual arranque Interruttore differenziale 30mA G F I Interrupteur diff rentiel Interruptor diferencial 30 mA Fusibile Fuse Fusible Fusible Spia luminosa corrente alternata A C output indicator Voyants tension alternative Indicadores luminosos c alter Contaore Hour counter Compte heures Cuentahoras Regolatore corrente di saldatura Welding current regulator R gulateur courant soudage Regulador corr de soldadura Spia carica batteria Battery charge warning light Voyant charge batterie Piloto carga bateria Spia lumin press olio oil alert Oil press warning light oil alert Voyant lumin press huile oil alert Indic lum pres aceite oil alert Chiave di avviamento Starter key Cl de d marrage Llave de arranque Batteria Battery Batterie Bater a Interruttore comando a distanza Remote control switch Commutateur t l commande Interruptor ma
12. or safety respecting completely the laws and or dispositions in force in the place ENGINE and ALTERNATOR PLEASE REFER TO THE SPECIFIC MANUALS PROVIDED Every engine and alternator manufacturer has e Do not modify the components if not authorized HOT surface can hurt you maintenance intervals and specific checks for each model it is necessary to consult the specific engine or alternator USER AND MAINTENANCE manual VENTILATION Make certain there are no obstructions rags leaves or other in the air inlet and outlet openings on the machine alternator and motor ELECTRICAL PANELS Check condition of cables and connections daily Clean periodically using a vacuum cleaner DO NOT USE COMPRESSED AIR DECALS AND LABELS All warning and decals should be checked once a year and replaced if missing or unreadable STRENUOUS OPERATING CONDITIONS Under extreme operating conditions frequent stops and starts dusty environment cold weather extended periods of no load operation fuel with over 0 5 sulphur content do maintenance more frequently BATTERY WITHOUT MAINTENANCE DO NOT OPEN THE BATTERY The battery is charged automatically from the battery charger circuit suppplied with the engine Check the state of the battery from the colour of the warning light which is in the upper part Green colour battery OK Black colour battery to be recharged White colour battery t
13. 0 M6GB Il CD D r D ERA Set up for operation Engine diesel MOSA 1 1 09 05 BATTERY WITHOUT MAINTENANCE Connect the cable positive to the pole positive of the battery after having taken away the protection by properly tightening the clamp Check the state of the battery from the colour of the warning light which is in the upper part Green colour battery OK Black colour battery to be recharged White colour battery to be replaced DO NOT OPEN THE BATTERY Ez LUBRICANT RECOMMENDED OIL MOSA recommends selecting AGIP engine oil Refer to the label on the motor for the recommended products Please refer to the motor operating manual for the recommended viscosity REFUELLING AND CONTROL Carry out refuelling and controls with motor at level position 1 Remove the oil fill tap 24 2 Pour oil and replace the tap 3 Check the oil level using the dipstick 23 the oil level must be comprised between the minimum and maximum indicators N ATTENTION It is dangerous to fill the motor with too much oil as its combustion can provoke a sudden increase in rotation speed Y Check that the dry air filter is correctly installed and that there are no leaks around the filter which could lead to infiltrations of non filtered air to the inside of the motor DRY AIR FILTER Air cooled systems 2 OIL BATH AIR FILTER Fill the air filter using the same engine oil up to
14. 06 Fino a Up to REV 1 11 06 Del 202 06 Fino a Up to REV 1 11 06 Del 202 06 Fino a Up to REV 1 11 06 Del 202 06 20 11 06 20 11 06 20 11 06 20 11 06 20 11 06 20 11 06 20 11 06 26 05 05 27292 l Ricambi 9 Ersatzteile M BR SA Spare parts CE Tabla de ricambios TS 200 DES EL REV 1 04 07 CF Pi ces de rechange QUO O NO 33 26 05 05 27292 l MOSA Pos Rev Cod 1 107509702 2 836709715 3 0000836709701 4 102042740 5 307017037 6 305159880 T 218017226 8 102013290 9 272920042 10 307759045 11 1291250 12 105511810 13 1302220 13 1302530 14 272927010 15 232027036 16 105111540 17 232027130 18 305907270 19 272927020 20 306467107 21 307017240 22 218137280 23 873407107 24 282009807 25 208019800 26 208019801 27 107509870 28 218019874 29 272707015 30 272708005 31 272708235 32 102301310 33 102044400 34 1302040 34 1302500 35 107302460 CD Ricambi Spare parts 9 Ersatzteile CE Tabla de ricambios TS 200 DES EL CF Pi ces de rechange Descr Note MANOPOLA REG CORRENTE SALDAT KNOB WELDING CURRENT REGULAT GR POTENZIOMETRO WELDING CURRENT REGULATOR GR POTENZIOMETRO WELDING CURRENT REGULATOR CAPPUCCIO CAP STAFFA BRACKET BOX CONDENSATORI CAPACITOR BOX 3X75 MORSETTIERA TERMINAL BOARD COMMUTATORE COMMUTATOR CONNETTORE COMPL DI CAVI CONNECTOR COMPL WITH CABLES PORTAFUSIBILE FUSE HOLDER FUSIBILE FUSE CONTAORE 230V 50Hz IP65 HOURMETER 2
15. 11180 RONDELLA WASHER 6075020 COPIGLIA PIN SPLIT 105311650 RUOTA WHEEL CTM 200 232120130 Pos Rev Cod Desert Deser 1 107012150 CAVALLOTTO U BOLT 2a 208101051 MANIGLIA HANDLE 7 205311160 ASSALE AXLE 8 205311180 RONDELLA WASHER 9 6075020 COPIGLIA PIN SPLIT 10 105311650 RUOTA WHEEL 12 12 13 14 PB3 256020040 feel Cod Deser __ Desc Mote 256020549 GR COPERCHIO COMPLETO COMPLETE COVER 256029168 CESTELLO PORTA BATTERIA BATTERY HOLDER 256029160 CESTELLO P BATT COPERCHIO BATTERY HOLDER WITH COVER 209509150 BATTERIA BATTERY fino a up to REV 0 04 97 Del 74 05 del 15 07 05 372859150 BATTERIA BATTERY da from REV 1 10 05 Del 74 05 del 15 07 05 21 04 97 KA MOSA D GB REV 1 07 07 CF TC 2 TC2 50 209510018 930600000 70 I l N I i NN l l dad d I I l l l r Y ES SQ d l VA 100 7 lt Ba atte 1 SELETTORE CORRENTE q RANGE 7 N b d y Lea n y 100 Val j 130Amax Y d Sa AE ON V l Y Y EK ech Ki VW A ly N 2 Ti 1 y Le ANA OFF I ps I v Va d TEAD d l I I N la d 277 ila A b 3 l Mx LY Y 1 P Tey i I 188 SC 7 4444 I Seo N S z lt ey y 7 57 L7 l Su EE E eee 5 7 9 d 4 TC 2 11 TC 2 4A TC 2 50 11A TC 2 50 Descr 209519904
16. 21 fax 39 0290390466 Made n VEJTALY http www mosait e mail infoemosa it ie NU C 1 Ir ALTIT iOO m 25 C Mass RPM nj RPM gef Kwik eL Ce Furthermore on each model it is shown the noise level value the symbol used is the following WS we ys dB 10 10 02 M1 4 GB The indication is shown in a clear readable and indeleble way on a sticker Dichiarazione conformit D gt Konformitatserklarung M DU SA GB Declaration of conformity E gt Declaraci n de conformidad REV 0 06 10 CF D claration de conformit ND BCS S p A Stabilimento di Cusago 20090 MI Italia V le Europa 59 Tel 39 02 903521 Via Marradi 1 20123 Milano Italia Fax 39 02 90390466 ISO 9001 2000 Cert 0192 Sede legale DICHIARAZIONE DI CONFORMITA D claration de Conformit Declaration of Conformity Konformitatserklarung Conformiteitsverklaring Declaracion de Conformidad BCS S p A dichiara sotto la propria responsabilita che la macchina BCS S p A d clare sous sa propre responsabilit que la machine BCS S p A declares under its own responsibility that the machine BCS S p A erkl rt da die Aggregate BCS S p A verklaard onder haar eigen verantwoordelijkheid dat de machine BCS S p A declara bajo su responsabilidad que la maquina GRUPPO ELETTROGENO DI SALDATURA WELDING GENERATOR H GRUPPO ELETTROGENO POWER GENERATO
17. 30V 50Hz IP65 SPIA 230V WARNING LIGHT 230V Fino a REV 1 04 07 Del 52 08 03 03 08 SPIA 230V WARNING LIGHT 230V Da REV 2 05 08 Del 52 08 03 03 08 SCATOLA ELETTRICA ELECTRIC BOX GUIDA FIXING GUIDE Vedi Cod 219937105 See part no 219937105 CAPPUCCIO PROTEZIONE 1 D CAP PRESA CEE 16A 400V 3P N T EEC SOCKET 16A 400V 3P N T PANNELLO FRONTALE FRONT PANEL DISGIUNT TERMICO 20AMP 250 V THERMOPROTECTION 20AMP 250 V PRESA 220V 16A EEC SOCKET 16A 220V 2P T PRESA CEE 48V 32A EEC SOCKET 48V 32A DISGIUNTORE TERMICO 30A 250V CIRCUIT BREAKER 30A 250V DISTANZ ISOLANTE PER SCHEDE SPACER SCHEDA DI CONTROLLO SALDATURA PCB WELDING CONTROL STAFFA BRACKET TRASFORMATORE AUXILIARY TRANSFORMER STAFFA BLOCC TRASFORM AUSIL BRACKET COPERCHIO SCATOLA ELETTRICA COVER ELECTRICAL BOX CARENATURA FRAME GRIGLIA DI ASPIRAZIONE INTAKE GRATE PRESA DI SALDATURA WELDING SOCKET PRESA DI SALDATURA WELDING SOCKET SPIA ROSSA 12V RED WARNING LIGHT 12V Da From REV 1 04 07 Del 202 06 20 11 06 Fino a REV 1 04 07 Del 52 08 03 03 08 Da REV 2 05 08 Del 52 08 03 03 08 Da From REV 1 04 07 Del 202 06 20 11 06 SPIA ROSSA 12V RED WARNING LIGHT 12V STARTER A CHIAVE STARTER KEY 26 05 05 27292 l D CTM 6 2 GB 212029080 OMOSA REV 1 10 05 CF N Pos Rev Cod Deser__ Desc __ _ _ Note 107012150 CAVALLOTTO 107012130 MANIGLIA HANDLE 205311160 ASSALE AXLE 2053
18. 40 96 euoizezzuojne ens ezues Gilet e o jeoiunuJoo o Ip uoo ouBesip ejuesaud ap eyeudoud ei e669 Ip tuwa e IS YSON 7 aoe y Ov0 S Z6ZZZ S002 S06L N 89e10d317 13 830 002 SLI y esou mmm y Joubisag auyoen bego ATYLI IN ODVSNI 0600Z eJojeuBesiq BuIyosel Bed ely Ujo Lu abed JoaloJd uoneuiuoueq pora UJOJ J Ulp u Beg oneBoJud euoizeutiuoue q bed eq aay seq a1ed uddy sid gei COUPON ALOWSY TS 200 DES EL TS 200 LDES EL o O Ran fei O O E o LLI c amp e tj 5 E o E dy vV Y oO fei o V E lt V i cl OL LL REV 0 05 05 CD Schema elettrico M D CA Electric diagram MOSA guarantees that any request for spare parts will be satisfied To keep the machine in full working order when replacement of MOSA spare parts is required always ask for genuine parts only 55 The requested data are to be found on the data plate located on the machine structure quite visible and easy to consult When ordering the spare parts it is recom mended to indicate O MIDA Europa 59 20090 CUSAGO MI ITALY gt Tel 39 02 90352 1 fax 39 02 90390466 1 serial number _ cum TS 0000 GE 2 model of welder and or generating set lt 4 n position gt quantity
19. CONNETTORE COMPLETO DI CAVI CONNECTOR WITH CABLES TC2 vers 930609904 CONNETTORE CON CAVI CONNECTORS WITH CABLES TC2 50 vers 107509702 MANOPOLA REG CORRENTE SALDAT KNOB WELDING CURRENT REGULAT 107509700 POTENZIOMETRO WELDING CURRENT REGULATOR Fino a Up to REV 10 99 Del 129 06 04 09 07 836709715 POTENZIOMETRO WELDING CURRENT REGULATOR Da From REV 07 07 Del 129 06 04 09 07 107509900 SCATOLA CASE BOTTOM HALF 209519901 COPERCHIO CD COVER 209510018 TC2 COMANDO DISTANZA STD TC2 STD REMOTE CONTROL 930600018 102 50 COMANDO DISTANZA STD TC2 50 STD REMOTE CONTROL 18 10 99 KD
20. HEAT Hot surfaces If the advice is not respected burns or damage to things can be caused EXPLOSION Explosive material or danger of explosion in general If the advice is not respected there can be explosions WATER Danger of shortcircuit If the advice is not respected fires or damage to persons can be caused SMOKING The cigarette can cause fire or explosion If the advice is not respected fires or explosions can be caused ACIDS Danger of corrosion If the advice is not respected the acids can cause corrosions with damage to persons or things WRENCH Use of the tools If the advice is not respected damage can be caused to things and even to persons PRESSION Danger of burns caused by the expulsion of hot liquids under pressure p gt gt bO00bb bp gt P peste A ACCES FORBIDDEN to non authorizad peaple SYMBOLS AND SAFETY PRECAUTIONS PROHIBITIONS No harm for persons Use only with safety clothing a It is compulsory to use the personal Mun protection means given in equip ment Use only with safety clothing A It is compulsory to use the personal protection means given in equipment Use only with safety protections Itis a mustto use protection means suitable for the different welding works e with only safety material It is prohibited to use water to quench fires on the electric machines ch with non inserted voltage It is prohibited to make interventions before ha
21. OTORE YANMAR L100AE DEG YANMAR ENGINE L100AE DEG MOTORE YANMAR L100AE DEG YANMAR ENGINE L100AE DEG MOTORE YANMAR L100N YANMAR ENGINE L100N MOTORE LOMBARDINI 15LD440 LOMBARDINI ENGINE 15LD440 REATTANZA DI LIVELLO REACTOR ALBERO CON ROTORE SHAFT WITH ROTOR CUSCINETTO BEARING PROTEZIONE ANTIVIBRANTE PROTECTION VIBRATION DAMPER ANTIVIBRANTE VIBRATION DAMPER VENTOLA CON FASCETTA FAN RONDELLA WASHER RONDELLA WASHER TIRANTE TIE ROD GR PONTE DIODI DIODE BRIDGE ASSY STAFFA BRACKET SCATOLA DI BASE CASE BOTTOM HALF BARELLA PROTECTIVE FRAME DISGIUNTORE TERMICO 15A 250V THERMAL SWITCH 15A 250V SPIA ROSSA 12V RED WARNING LIGHT 12V PANNELLO PANEL STARTER A CHIAVE STARTER KEY REGOLATORE DI TENSIONE VOLTAGE REGULATOR SCATOLA SUPPORTO REGOLATORE BOX SUPPORT REGULATOR STAFFA SUPP FISS SCATOLA BRACKET TS 200 DES EL Note Fino a Up to REV 1 11 06 Del 202 06 20 11 06 Da From REV 2 04 07 Del 202 06 20 11 06 Fino a Up to REV 1 11 06 Del 202 06 20 11 06 Da From REV 2 04 07 Del 202 06 20 11 06 Fino a Up to REV 2 04 07 Del 261 08 03 12 07 Da From REV 3 05 08 Del 261 08 03 12 07 Da From REV 4 11 11 Del 107 11 27 10 11 Fino a Up to REV 0 10 98 Del 91 06 07 06 06 Da From REV 1 11 06 Del 91 06 07 06 06 Fino a Up to REV 1 11 06 Del 202 06 Fino a Up to REV 1 11 06 Del 202 06 Fino a Up to REV 1 11 06 Del 202 06 Fino a Up to REV 1 11 06 Del 202
22. R Marchio Brand Modello Model Matricola Serial number e conforme con qua est en conformit a conforms with the C mit den Vorschriften di in overeenkomst is m t de nhoud van gemeenschapsrichtliinemen gerelateerde modificaties comple con los requisitos de la Directiva Comunitaria y sus anexos 2006 42 CE 2006 95 CE 2004 108 CE Nome e indirizzo della persona autorizzata a costituire il fascicolo tecnico Nom et adresse de la personne autoris e a composer le Dossier Technique Person authorized to compile the technical file and address Name und Adresse der zur Ausfullung der technischen Akten ermachtigten Person Persoon bevoegd om het technische document en bedrijf gegevens in te vullen Nombre y direccion de la persona autorizada a componer el expediente tecnico ing Benso Marelli Amministratore Delegato CEO V le Europa 59 20090 Cusago Ml Italy Cusago g Benso Marelli Amministratore Delegato CEO MM 083 0 04 06 10 M1 4 1 Technical data TS 200 DES EL Technical data TS 200 DES EL D C WELDING C C Duty cycle 170A 60 130A 100 Welding current regulation I scale 20 170A Welding voltage 65V GENERATOR Three phase generation 6 kVA 400V 8 7 A Single phase generation 5 kVA 230V 21 7 A Single phase generation 2 5 KVA 110 V 22 7 A Single phase generation 2kVA 48V 41 6A Frequency 50 Hz Cos 0 8 ALTERNATOR Self excited self regulated Type three phase asynchr
23. TOIDLE switch AUTOIDLE PCB A4E2 ECM engine PCB Remote emergency stop connector VIA digital instruments and led VRD PCB Water in fuel Battery disconnect switch Inverter Overload led Main IT TN selector NATO socket 12V Diesel pressure switch Remote control PCB Pressure turbo protection Water in fuel sender EDC7 UC31 engine PCB Low water level sender Interface card Limit switch Starter timing card Luquid pouring level float Under voltage coil Low water level warning light Chopper driver PCB 26 07 04 M60GB Il 26 Z2c 30 40 96 QUOIZEZZOINE ens ezuas IZ19 O EIUNWOD o oUDDOIdu ip Ozalp uo oubasip ajuasaid op eyeudoud e abba ip iue e 95 IS YSOW EI V 0LO S 9v9GSZ 00Z 01 ZZ N aoejoda7 9 SAC 0009 AD lt F y A 66 u BMG ajed Jeuiseq GUIDEN lt ATVLI IIN ODVSNI 0600Z iU SI eleg auoyeuBbasiq BUIYOOE N Bed AV00L7 4ewue euibu3 gt 3oelougd uoneuiuoue m wol4 0peBold auoizeuiuouaq Bed eq UOneogipop ES eoiJipo A 53 d 90026062 euoneq Home Ip 013 dW09 aJojou OAONU UOI BWAUDS O DIJIDO ul Hb be 9002 60 62 Seq eol OMe Ip 1 uos oyeoyipoyw y del LLI A o o N O ORSO FE RS ai r 717 I I 9 1 gt gt C I aB gt O LEI D EL sg ey A a VOZ E g O SE E 5
24. TS 200 DES EL TS 200 LDES EL 272929003 GB USE AND MAINTENANCE MANUAL SPARE PARTS CATALOG MOSA 26 05 05 27292M00 arato da UPT approvato da DITE CD CISA co DESCRIPTION OF THE MACHINE TS 200 DES EL REV 1 11 11 TS 200 LDES EL The TS 200 engine driven welder ia a unit which ensures the function as a a current source for are welding b a current source for the auxiliary generation Unit meant for industrial and professional use powered by an endothermic engine it is composed of various main parts such as engine alternator electric and electronic controls the fairing or a protective structure The assembling is made on a steel structure on which are provided elastic support which must damp the vibrations and also eliminate sounds which would produce noise ENGINE VIBRATION CANOPY LU gt m 2 y 4 TW 5 S ALTERNATOR sarir a MOSA Quality system MOSA REV 3 02 09 CF THE INTERNATIONAL CERTIFICATION NETWORK CERTIFICATE IQNet and its partner hereby cer SRAGIM organization BCS S p A Head Office and Operative Unit Viale Mazzini 161 20081 Abbiategrasso Ml Operative Units Via Valbrina 17 19 42045 Luzzara RE Viale Europa 59 1 20090 Cusago Ml for the following field of activities Design production and servicing of tractors agricultural and green maintenance machines engine driven welders and generating se
25. ange Commutator switch series parallel Commutator switch Key switch on off QEA control unit Connector PAC Frequency rpm regulator Arc Force selector Device starting motor Fuel electro pump 12V c c Start Local Remote selector Choke button Switch CC CV Connector wire feeder 420V 110V 3 phase transformer Switch IDLE RUN HZ V A analogic instrument EMC filter Wire feeder supply switch Wire feeder socket DSP chopper PCB Power chopper supply PCB Switch and leds PCB Hall sensor Water heather indicator Battery charge indicator Transfer pump selector AUT 0 MAN Fuel transfer pump GECO generating set test Flooting with level switches Voltmeter regulator WELD AUX switch Reactor 3 phase Switch disconnector Solenoid stop timer VODIA connector F EDC4 connector OFF ON DIAGN selector DIAGNOSTIC push button DIAGNOSTIC indicator Welding selector mode VRD load 230V 1 phase plug VIHz analogic instrument Engine protection EP6 G F I relay supply switch Radio remote control receiver Radio remote control trasnsmitter Isometer test push button Remote start socket Transfer fuel pump control Ammeter selector switch 400V 230V 115V commutator 50 60 Hz switch Cold start advance with temp switch START STOP switch Polarity inverter two way switch Engine protection EP7 AU
26. circuited REMOTE CONTROL TC See page M 38 N ATTENTION To reduce the risk of electromagnetic interference keep the welding cable length short and keep them on or near the ground If possible welding opera tions should not be done near sensitive electronic devices If interference continues to occur adopt additional measures shift the group use shielded cables line filters shield the entire work area If the above solutions do not suffice consult our Technical Servicing Department 30 11 06 27292 GB 7000 USE AS A GENERATOR N DANGEROUS It is strictly forbidden to connect the group to the ublic mains a o to another source of electric power W electricity generating group for all non authorized personnel The electricity generating groups are to be considered electrical energy producing stations The dangers of electrical energy must be considered together with those related to the presence of chemical substances fuels oils etc rotating parts and waste products fumes discharge gases heat etc Access forbidden to area adjacent to RPM VOLTAGE FREQUECY The engine speed determines the values of voltage and frequency of the auxiliary generation system Check the proper engine operation at its nominal speed before each usage Do not modify the regulation of the engine rom Speeds different from the rated one can worsen the performan ces and even the reliability of the machine
27. d or current regulations in force for electrical installations and safety 10030 16 07 03 M20 R A GB TS 200 DES EL ELECTRIC STARTING check daily E Do not alter the primary conditions of regulation and do not touch the sealed parts 1 Open the fuel cock ME 2 Accelerator lever must be in the START position 3 Turn the starter key to the START position Once the engine has started let the key return to the ON position OFF MS ON NN START Let the engine run for some minutes before drawing the load ie In case of unsuccessful start up do not insist for longer than 5 seconds Wait 10 seconds before attempting another start up EMERGY STARTING with starting handle 1 hold the starting handle pro perly 2 pull the starting handle slowly until you feel resistance 3 then return it slowly 4 push the decompression le ver down and release 5 pull the rope hard and fast Pull it all the way out Use two hands if necessary ATTENTION If battery is not connected disconnect voltage re gulator to prevent damage STOP THE ENGINE r Before stopping the engine it is compulsory to stop the load shut off any loads which are connected to the unit auxiliary outputs disconnect the electric protection device D stop welding To stop the engine AIA ib Move the engine speed lever to E the STOP position Remove the key
28. e engine stopping The same as for as the battery charger warning O1 light in concerned the anomaly is shown without the engine stopping If the trouble should persist please turn to your Assistance Centre Once the cause of the problem is removed to assu re the protection it is enough to put the starting key Q1 to zero OFF position and start the engine again TS 200 DES CF TS 200 DES LDES EL cae 04 11 02 27270 GB Troubleshooting WELDING TS 200 DES EL TS 200 LDES EL Solution P1 No welding current but auxiliary output is OK P2 Defect in welding high and discon tinued sparks P3 No welding output and no auxiliary power output 1 Position of remote control switch 2 Potentiometer defect in welding current control 3 Welding current signal interrupter 4 Defect card 5 Defect in diode bridge 1 Defect in connections between shunt and potentiometer 2 Defect in diode bridge 3 Defect in card 1 Short circuit in wiring 2 Defective condenser 3 Defective stator 4 Short circuited diode bridge 1 Check that it is in OFF position if there is no remote control on ON with remote control inserted 2 Check the continuity of the welding potentiometer and relative connections 3 Check that cables from shunt to card are in perfect state 4 Replace card 5 Check the diode or the controlled diodes 1 Check the continuity and the state of different connect
29. ers of the product to be used in the welding process RUTILE ELECTRODES E 6013 Easily removable fluid slag suitable foe welding in all position Rutile electrodes weld in d c with both polarities electrode holder at or and in a c Suitable for soft steels R 38 45 kg mm Also for soft steels of lower quality BASIC ELECTRODES E 7015 Basic electrrodes wels onlu in d c with inverse polarity on the electrode holder there are also types for a c Suitable for impure carbon steels Weld in all position HIGH YIELD BASIC ELECTRODES E 7018 The iron contained in the coating increases the quality of metal added Good mechanical properties Weld in all position Electrode holder at inverse polarity Wid deposit of nice aspect also vertical Workable high yield Suitable for steels with high contens of sulphur impurities CELLULOSIC ELECTRODES E 6010 Cellulosic electrodes weld only in d c with polarity electrode holder ground clamp Special for steels run on pipes with R max 55 kg mm Weld in all position volatile slag ELECTRODES IDENTIFICATION ACCORDING TO A W S STANDARDS 2 digits type of coating and electric power conditions see table 3 1 digits welding positions see table 2 Li Descrizione 2 3 digits tesile strenght of g 9 Cellulose electrodes for d c the weld deposit see table 1 Cellulose electrodes for a c symbol for Rutile electrode for d c Coated Rutile electr
30. g circuit 110V D C 48V D C diode bridge E P 1 engine protection Engine stop solenoid Acceleration solenoid Fuel level transmitter Oil or water thermostat 48V D C socket Oil pressure switch Fuel warning light Battery charge warning light Oil pressure warning light Fuse Starter key Starter motor Battery Battery charge alternator Battery charge voltage regulator Solenoid valve control PCBT Solenoid valve Remote control switch Remote control and or wire feeder socket Remote control plug Remote control welding regulator E P 2 engine protection Fuel level gauge Ammeter Frequency meter Battery charge trasformer Battery charge PCB Voltage selector switch 48V a c socket Thermal relay Contactor G F I and circuit breaker 42V EEC socket GEI resistor T E P engine protection Solenoid control PCBT Oil level transmitter Engine stop push button T C 1 Engine start push buttonT C 1 24V c a socket Thermal magnetic circuit breaker S C R protection unit Remote control socket Remote control plug Insulation moitoring E A S connector E A S PCB Booster socket Open circuit voltage switch Stop push button Ignition coil Spark plug Range switch Oil shut down button Battery charge diode Relay Resistor Sparkler reactor Output power unit Electric siren E P 4 en
31. g fumes by providing a ventilation system or if not possible use an approved air breather Do not work in closed areas where there is no fresh air flow Protect face and eyes protective mask with suitable dark lens and side screens ears and body non flamable protective clothers Mn 30 03 00 M2 5GB CD MOS A amp INSTALLATION AND ADVICE AA A p mque MOSA REV 1 06 07 INSTALLATION AND ADVICE BEFORE USE Check that the air gets changed completely and the hot air sent out does not come back inside the set so as to cause a dangerous increase of the temperature GASOLINE ENGINES t Use in open space air swept or vent exhaust gases which contain the deathly carbone oxyde far from the work area DIESEL ENGINES t Use in open space air swept or vent exhaust gases far from the work area t Make sure that the machine does not move during the work block it possibly with tools and or devices made to this purpose MOVES OF THE MACHINE t At any move check that the engine is off that there are no connections with cables which impede the moves PLACE OF THE MACHINE ATTENTION For a safer use from the operator DO NOT fit the machine in locations with high risk CR gt of flood POSITION Please do not use the machine in weather Place the machine on a level surface at a distance of at sti 9 conditions which are beyond IP protection least 1 5 m from buildings o
32. gine protection Engine control PCB R P M electronic regulator PTO HI control PCB PTO HI 20 l min push button PTO HI 30 l min push button PTO HI reset push button PTO HI 20 l min indicator PTO HI 30 l min indicator PTO HI reset indicator PTO HI 20 l min solenoid valve PTO HI 30 min solenoid valve Hydraulic oil pressure switch Hycraulic oil level gauge Preheating glow plugs Preheating gearbox Preheating indicator R C filter Heater with thermostat Choke solenoid Step relay Circuit breaker Battery charge sockets Sensor cooling liquid temperature Sensor air filter clogging Warning light air filter clogging Polarity inverter remote control Polarity inverter switch Transformer 230 48V Diode bridge polarity change Base current diode bridge PCB control unit polarity inverter Base current switch Auxiliary push button ON OFF Accelerator electronic control Actuator Pick up Warning light high temperature Commutator auxiliary power 24V diode bridge YLA commutator Emergency stop button Engine protection EP5 Pre heat push button Accelerator solenoid PCB Oil pressure switch Water temperature switch Water heater Engine connector 24 poles Electronic GFI relais Release coil circuit breaker Oil pressure indicator Water temperature indicator Battery voltmeter Contactor polarity ch
33. he distance of measurement The here below table shows examples of acoustic pressure Lp at different distances from a machine with Acoustic Noise Level LWA of 95 dB A Lp a 1 meter 95 dB A 8 dB A 87 dB A Lp a 7 meters 95 dB A 25 dB A 70 dB A Lp a 4 meters 95 dB A 20 dB A 75 dB A Lp a 10 meters 95 dB A 28 dB A 67 dB A PLEASE NOTE the symbol E when with acoustic noise values indicates that the device respects noise emission limits according to 2000 14 CE directive 30 11 06 27292 GB Technical data TS 200 LDES EL Technical data TS 200 LDES EL D C WELDING C C Duty cycle 170A 60 130A 100 Welding current regulation I scale 20 170A Welding voltage 65V GENERATOR Three phase generation 6 kVA 400V 8 7 A Single phase generation 5 kVA 230V 21 7 A Single phase generation 2 5 KVA 110 V 22 7 A Single phase generation 2kVA 48V 41 6A Frequency 50 Hz Cos 0 8 ALTERNATOR Self excited self regulated Type three phase asynchronous Insulating class H ENGINE Mark Model Lombardini 15LD440 Type Cooling system Diesel 4 Stroke air Cylinders Displacement 11442 cm Output 6 8 kW 9 2 HP Speed 3000 rpm Fuel consumption Welding 60 1 I h Engine oil capacity 1 51 Starter electric GENERAL SPECIFICATIONS Tank capacity 51 Running time Welding 60 4 5 h Protection IP 23 Dimensions Lxwxh mm 900x550x620 Weight 130 Kg Acoustic power LwA pression LpA 102 dB A 77 dB A 7 m
34. he getting rid of the various components of the machine must be made accordingly to rules in force of law a o local rules Particular attention must be paid when getting rid of lubricating oils battery electrolyte and infla mable liquids such as fuel cooling liquid The machine user is responsible for the observance of the norms concerning the environment conditions with regard to the elimination of the machine being cust off and of all its components In case the machine should be cust off without any previous disassembly it is however compulsory to remove tank fuel engine lubricating oil cooling liquid from the engine battery NOTE BCS is involved with custing off the machine only for the second hand ones when not reparable This of course after authorization In case of necessity for first aid and fire prevention see page M2 5 N IMPORTANT In the cust off operations avoid that polluting substances liquids exhausted oils etc bring damage to people or things or can cause negative effects to surroindings health or safety respecting completely the laws and or dispositions in force in the place 9 O1 04 06 07 M45GB et El M O SA RECOMMENDED ELECTRODES in accordance with A W S Standard MOSA 1 0 10 03 CE The information here below are to be intended only as indicative since the above norm is much larger For further details please see the specific norms and or the manufactur
35. ico M O CA Electric diagram pal ens ezues IZI8 e E O Ip 1 uoo oufesip ajuasald ap eyeudoud e 669 tuwa e eAjesu IS SOIN 87 89610067 13 830 002 SL E ie Set S d ATYLI IN ODWSND 06002 910 2UD9SI abl guguwioua abeg wo Ki ere QIN 90021191 euajjeq 9 89 ezues OAONU uoo y eojeujeye ojinj1sos y QD 0 V9ADY Nk VOZ _ voci SS II 1 90 90 92 30 40 96 euoizezzuojne ens ezues e ojjeoiunujoo o ip 1 uoo ouBesip ejuesaud jap eyeudoud ej e669 Ip IULIIS e eaS IS YSON 87 YO 13 830 002 SL lt _ a djy l SUE E Jeufiiseq SUIYIEN lt C ATVLI IIN ODVSNI 0600Z a Bed EI 9JojeuBesi euluooelN j JOMOd Buipem _ gt uoneuiuoue a UJOJ J 0abold euoizeuluoue q Bea eg UOREdIIPOW l LLI o LLI o N o E TS 200 LDES EL o 5 o c O s Olt eNO ana 5 l I E E o S i 9 A LIHM Em I o ul dau lt S oe v 000 i ei I r SS o e I rod I gt I I SE ps oio Po I E DO D Set nm o I e E I ocu J X4 WE en see eee teeee di E lt o 2 6 Y LL V MOSA REV 0 05 05 30
36. ing norms or local ones EXTINCTION MEANS Appropriated Carbonate anhydride or carbon dioxyde powder foam nebulized water Not to be used Avoid the use of water jets Other indications Cover eventual shedding not on fire with foam or sand use water jets to cool off the surfaces close to the fire Particular protection Wear an autorespiratory mask when heavy smoke is present Useful warnings Avoid by appropriate means to have oil sprays over metallic hot surfaces or over electric contacts switches plugs etc In case of oil sprinkling from pressure circuits keep in mind that the inflamability point is very low THE MACHINE MUST NOT BE USED IN AREAS WITH Ex PLOSIVE ATMOSPHERE 10 06 00 M2 51 CD MOS amp PRECAUTION ENGINE DRIVEN WELDER GE MS TS_ T ee MOSA 1 0 03 00 INSTALLATION AND ADVICE BEFORE USE The operator of the welder is responsible for the security of the people who work with the welder and for those in the vicinity The security measures must satisfy the rules and regulations for engine driven welders The information given below is in addition to the local security norms Estimate possible electromagnetic problems in the work area taking into account the following indications Telephonic wirings and or of communication check wirings and so on in the immediate vicinity Radio and television receptors and transmettors Computer and other checking devices Critical devices for
37. ions which go to the card from the shunt as well as from the potentiometer 2 Check the diodes and controlled diodes 3 Replace the card 1 Check the wiring inside the welder for a short circuit between cables or to ground 2 If the wiring is OK short circuit the condenser to be sure that it is discharged disconnect all wires from condenser and using an ohmmeter check that the condenser is not short circuited If the condenser box is OK disconnect all leads from the stator except for those going to the condenser box and check the output from the alternator If there is no output from the welding winding and the auxiliary winding replace the stator If there is output from all windings reconnect the diode bridge and check if there is welding current If not the diode bridge is defective If there is welding current connect the auxiliary power leads one at a time until there is no output at this point the short circuit is in that line GENERATION P1 Warning light POWER ONT off but 1 Warning light defect 1 Replace warning light regular voltage at the sockets P2 Three phase voltage not present at the socket but present on other sockets P3 Nosingle phase voltage one socket but reading is normal on the other sockets P4 No voltage present P1 The engine does not start or stops immediately after startup P2 The battery does not charge Bat tery charge warning light N1 lit P3 For other problems refer t
38. les service of the engine manufacturer Clean the covers and all the other parts of the machine carefully Protect the machine with a plastic hood and store it in a dry place In case of necessity for first aid and of fire prevention see page M2 5 IMPORTANT In the storage operations avoid that polluting substances liquids exhausted oils etc bring damage to people or things or can cause negative effects to surroindings health or safety respecting completely the laws and or dispositions in force in the place G ss 04 06 07 M45GB gt Have qualified personnel disassemble the machine and dispose of the parts including the oil fuel etc in a correct manner when it is to be taken out of service As cust off we intend all operations to be made at utilizer s care at the end of the use of the machine This comprises the dismantling of the machine the subdivision of the several components for a further reutilization or for getting rid of them the eventual packing and transportation of the eliminated parts up to their delivery to the store or to the bureau encharged to the cust off or to the storage office etc The several operations concerning the cust off invol ve the manipulation of fluids potentially dangerous such as lubricating oil and battery electrolyte The dismantling of metallic parts liable to cause injuries or wounds must be made wearing heavy gloves and using suitable tools T
39. letely in the sockets turning clockwise to lock them in place PUSH AND TWIST 1201 kh Connect the earth clamp to the negative pole and the electrode holder to the positive t Pay attention to the two polarities on the welding circuit which must not come into electrical con tact with each other Carefully tighten the output cables to the bushings if loose they can cause problems of overheating and damage the bushings cables etc Make certain the grounding pincer is connected as near as possible to the work station A CAUTION _ With a welding cable length up to 20 m is suggested a section of 35 mm with longer cables a bigger section is required ADJUSTING THE WELDING CURRENT For every welding current chosen the machine shall run at its nominal speed WARNING Do not modify the regulation of the engine rpm Speeds different from the rated one can worsen the performances and even the reliability of the machine The welding current is regulated by turning knob T continuously If set to the minimum turned fully in an anticlockwise direction it provi E des a current of approximately 30 A if set to the maximum turned fully in a clockwise direction it gives a maximum current of approximately 170A 20V RECOMMENDED ELECTRODES All the electrodes on the market can be used Protection fuse The fuse protects the electronic welding PCB in case the remote control is short
40. limits according to 2000 14 CE directive 30 11 06 27292 GB A TS 200 DESIEL MOS A amp Technical data TS 200 LDES EL REV 0 11 11 CFD Technical data D C WELDING Welding current regulation 20 170A Service 170A 60 130 A 100 Welding voltage 65 V OUTPUT CARACTERISTIC viv 100 90 80 70 60 50 40 30 20 10 0 A SIMULTANEOUS UTILIZATION FACTORS In case Welding and Generation can be used simultaneously however the engine cannot be overloaded The table below gives the maximum limits to be respected WELDING CURRENT gt 100 A 80 A 50 A THREE PHASE WELDING CURRENT 1 o 1KVA zswa swa SS SINGLE PHASE WELDING CURRENT 30 11 06 27292 GB D MOSA MOSA 1 0 11 99 SYMBOLS IN THIS MANUAL The symbols used in this manual are designed to call your attention to important aspects of the operation of the machine as well as potential hazards and dangers for persons and things IMPORTANT ADVICE Advice to the User about the safety cs N B The information contained in the manual can be changed without notice Potential damages caused in relation to the use of these instructions will not be considered because these are only indicative Remember that the non observance of the indications reported by us might cause damage to persons or things It is understood that local dispositions and or laws must be respected WARNING Situations of danger no harm to persons or things
41. ndo a distancia Presa per comando a distanza Remote control socket Prise pour t l commande Toma para mando a distancia 26 05 05 27292 l 1 Comandi 9 Bedienelemente MUSA 06 Controls Mandos TS 200 LDES EL REV 0 11 11 Commandes D 15 31 28 Pos Descrizione Description Description Descripci n 9 Presa di saldatura Welding socket Prise de soudage Toma de soldadura Presa di saldatura Welding socket Prise de soudage Toma de soldadura Presa di messa a terra Earth terminal Prise de mise a terre Toma de puesta a tierra Presa di corrente in c a A C socket Prises de courant en c a Toma de corriente en c a Filtro aria motore Engine air filter Filtre air moteur Filtro aire motor Asta livello olio motore Oil level dipstick Jauge niveau huile moteur Aguja nivel aceite motor Tappo caricamento olio motore Engine oil reservoir cap Bouchon remplissage huile moteur Tap n llenado aceite motor Tappo serbatoio Fuel tank cap Bouchon reservoir Tapon deposito Silenziatore di scarico Muffler Silencieux d chappement Silenciador de descarga Comando stop Stop control Commande stop Mando stop Tappo scarico olio motore Oil drain tap Bouchon d charge huile moteur Tap n vaciado aceite motor Protezione termica corrente aux Aux current thermal switch Protection thermique courant aux Protecci n t rmica corr aux Comando manuale avviamento Starting push button Commande manuelle
42. ng liquid tap if the liquid must be topped up faces during work operations BOARD The vapor and the heated cooling liquid under pressure can burn face eyes skin O Static electricity can demage Do not fill tank completely the parts on the circuit Wipe up spilled fuel before starting engine EE gens An electric shock can kill CHECKIN Shut off fuel of tank when moving machine where it is assembled Avoid spilling fuel on hot engine Sparks may cause the explosion of battery vapours or whatever event which may cause serious injuries or death predispose the first aid in accordance a GG FIRST AID In case the operator shold be sprayed by accident from corrosive liquids a o hot toxic gas with the ruling labour accident standards or of local instructions Skin contact Wash with water and soap Eyes contact Irrigate with plenty of water if the irritation persists contact a specialist Do not induce vomit as to avoid the intake of vomit into the lungs send for a doctor Suction of liquids from If you suppose that vomit has entered the lungs as in case of spontaneous vomit take the subject to the lungs hospital with the utmost urgency Inhalation In case of exposure to high concentration of vapours take immediately to a non polluted zone the person involved t FIRE PREVENTION In case the working zone for whatsoever cause goes on fire with flames liable to cause severe wounds or death follow the first aid as described by the rul
43. ng materials the User must keep to the norms in force in his country 1 Take the machine C out of the shipment packing Take out of the envelope A the user s manual B 2 Read the user s manual B the plates fixed on the machine the data plate A m O e CH Oo m e I e m TRANSPORT AND DISPLACEMENTS COVERED UNITS Transportation must always take place with the engine off electrical cables and starting battery disconnected and fuel tank empty Be sure that the lifting devices are correctly mounted adequate for the weight of the machine with it s packaging and conform to local rules and regulations Only authorized persons involved in the transport of the machine should be in the area of movement DO NOT LOAD OTHER PARTS WHICH CAN MODIFY WEIGHT AND BARICENTER POSITION IT IS STRICTLY FORBIDDEN TO DRAG THE MACHINE MANUALLY OR TOW IT BY ANY VEHICLE model with no CTM accessory If you did not keep to the instructions you could damage the structure of the machine Weight max per person 35 kg Total max weight 140 kg 15 01 01 M4GB carir A 0D MOSA c ASSEMBLY CTM 6 2 PB3 o REV 0 11 11 ATTENTION The CTM accessory cannot be removed from the machine and used separately actioned manually or following vehicles for the transport of loads or anyway for used different from the machine movements Note Lift the machine and assemble the parts as shown in the drawing ASA 10 06 0
44. o be replaced THE ENGINE PROTECTION NOT WORK WHEN THE OIL IS OF LOW QUALITY BECAUSE NOT CHARGED REGULARLY AT INTERVALS AS PRESCRIBED IN THE OWNER S ENGINE MANUAL 05 09 05 M43GB RS D MUUSA STORAGE REV 0 06 07 In case the machine should not be used for more than 30 days make sure that the room in which it is stored presents a suitable shelter from heat sources weather changes or anything which can cause rust corrosion or damages to the machine gt Have qualified personnel prepare the machine for storage GASOLINE ENGINE Start the engine It will run until it stops due to the lack of fuel Drain the oil from the engine sump and fill it with new oil see page M25 Pour about 10 cc of oil into the spark plug hole and screw the spark plug after having rotated the crankshaft several times Rotate the crankshaft slowly until you feel a certain com pression then leave it In case the battery for the electric start is assembled disconnect it Clean the covers and all the other parts of the machine carefully Protect the machine with a plastic hood and store it in o dry place DIESEL ENGINE For short periods of time it is advisable about every 10 days to make the machine work with load for 15 30 minutes for a correct distribution of the lubricant to re charge the battery and to prevent any possible bloking of the injection system For long periods of inactivity turn to the after so
45. o the attached engine manual 1 Differential switch not inserted 2 Differential switch malfunction 1 Intervention of thermal switch due to excessive current 2 Thermal switch malfunction 1 Short circuit present on the generator outputs 1 Low battery voltage battery dead or defective 2 Presence of air in the fuel supply circuit 1 Faulty battery charger 2 Battery charger alternator de fective 1 Turn on the switch 2 Replace the switch 1 Push in the thermal switch 2 Replace the thermal switch 1 Disconnect all outputs on the generator except for those on the condensers and re start machine check for voltage on condensers 1 Check the warning light battery condition Green colour battery OK Black colour battery to be recharged White colour battery to be replaced DO NOT OPEN THE BATTERY 2 Carry out de aeration on the fuel system See engine operating manual 1 Check the battery charger regulator replace if faulty 2 Replace 30 11 06 27292 GB MAINTENANCE Have qualified personnel do maintenance and troubleshooting work e Stop the engine before doing any work inside the machine If for any reason the machine must be operated while working inside pay attention moving parts hot parts exhaust manifold and muffler etc electrical parts which may be unprotected when the machine is open e Remove guards only when necessary to perform maintenance and replace them when
46. ode for a c electrode High yield rutile electrodes T 60 000 70 000 Basic electrodes for d c Basic electrodes for c a High yield basic electrodes for d c inverse polarity Acid electrodes for flat or front position welding for d c pole and for a c High yield rutile electrodes for flat or front plane position welding for d c and a c High yield acid electrodes for flat or front plane position welding for d c pole and a c High yield basic electrodes for flat or front plane Table 1 position welding for d c inverse polarity Extra high yield acid electrodes extra high penetration if required for flat position welding only for d c pole and a c 80 000 90 000 100 000 110 000 120 000 for all positions for plane and verticl for plane posotion only Table 2 Table 3 10 10 03 M55GB CD MOS A s ELECTRICAL SYSTEM LEGENDE AAA REV 9 06 11 lt SXN lt CH1DODAO VZSF cronimcoouz7 Alternator Wire connection unit Capacitor GEL Welding PCB transformer Fuse 400V 3 phase socket 230V 1phase socket 110V 1 phase socket Socket warning light Hour counter Voltmeter Welding arc regulator 230V 3 phase socket Welding control PCB Welding current ammeter Welding current regulator Current transformer Welding voltage voltmeter Welding sockets Shunt D C inductor Welding diode bridge Arc striking resistor Arc strikin
47. on with the use of the given information MOSA division of B C S S p A does not take any responsibility about the shown information on firms or individuals but keeps the right to refuse services or information publication which it judges discutible unright or illegal GE_ MS_ TS_ EAS 10 10 02 M1 01 GB GE_ MS_ TS_ EAS INFORMATION Dear Customer We wish to thank you for having bought from MOSA a high quality set Our sections for Technical Service and Spare Parts will work at best to help you if it were necessary To this purpose we advise you for all control and overhaul operations to turn to the nearest authorized Service Centre where you will obtain a prompt and specialized intervention rS In case you do not profit on these Services and some parts are replaced please ask and be sure that are used exclusively original MOSA parts this to guarantee that the performances and the initial safety prescribed by the norms in force are re established GG The use of non original spare parts will cancel immediately any guarantee and Technical Ser vice obligation from MOSA NOTES ABOUT THE MANUAL Before actioning the machine please read this manual attentively Follow the instructions contained in it in this way you will avoid inconveniences due to negligence mistakes or incorrect maintenance The manual is for qualified personnel who knows the rules about safety and health installation and use of sets mo
48. onnected to the unit auxiliary outputs disconnect the electric protection device D stop welding Move the STOP lever to the STOP position Remove the key Q1 don t ancharge the battery turning it counter clockwise OFF posi tion then take it out ts NB for safety reason the key must be kept by qualified personel AN CAVON RUNNING IN During the first 50 hours of operation do not use more than 60 of the maximum output power of the unit and check the oil level frequently in any case please stick to the rules given in the engine use manual 00309 en ki 30 11 06 27292 1 Comandi 9 Bedienelemente MUSA 6 Controls Mandos TS 200 DES EL REV 2 11 11 Commandes MO Pos Descrizione Description Description Descripci n 9 Presa di saldatura Welding socket Prise de soudage Toma de soldadura Presa di saldatura Welding socket Prise de soudage Toma de soldadura Presa di messa a terra Earth terminal Prise de mise a terre Toma de puesta a tierra Presa di corrente in c a A C socket Prises de courant en c a Toma de corriente en c a Comando acceleratore Accelerator stop lever Commande acc l rateur stop Mando de aceleraci n stop Filtro aria motore Engine air filter Filtre air moteur Filtro aire motor Asta livello olio motore Oil level dipstick Jauge niveau huile moteur Aguja nivel aceite motor Tappo caricamento olio
49. onous Insulating class H ENGINE Mark Model Yanmar L 100 N Type Cooling system Diesel 4 Stroke air Cylinders Displacement 1 435 cm Output 6 5 kW 8 8 HP Speed 3000 rpm Fuel consumption Welding 60 1 l h Engine oil capacity 1 6 Starter electric GENERAL SPECIFICATIONS Tank capacity 5 51 Running time Welding 60 5 9 fi Protection IP 23 Dimensions Lxwxh mm 900x550x620 Weight 133 Kg Acoustic power LwA pression LpA 99 dB A 74 dB A Q 7 m Dimensions and weight are inclusive of all parts without wheels and towbar CTM POWER Declared power according to ISO 3046 1 temperature 25 C 30 relative humidity altitude 100 m above sea level Its admitted overload of 1096 each hour every 12 h In an approximative way one reduces of 1 every 100 m altitude and of 2 5 for every 5 C above 25 C ACOUSTIC POWER LEVEL ATTENTION The concrete risk due to the machine depends on the conditions in which it is used Therefore it is up to the end user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions for instance adopting a I P D Individual Protection Device Acoustic Noise Level LWA Measure Unit dB A it stands for acoustic noise released in a certain delay of time This is not submitted to the distance of measurement Acoustic Pressure Lp Measure Unit dB A it measures the pressure originated by sound waves emission Its value changes in proportion to t
50. ping to rules and laws in force concerning safety and electric plant PLUGS and CABLES Before inserting a load into the machine check that the cable is in good condition its section fit for the drawn current and the plug inserted correctly WARNING LIGHT FOR PRESENCE OF VOLTAGE The carning light L POWER ONT shows when lit that the set can give current from the a c sockets In case the warning light not light up check that the engine runs at its rated value or that the GFI is inserted THERMIC PROTECTION Generally present to protect against overloads on an individual power socket c a When the nominal operating current has been exceeded the protection device intervenes by cutting off power to the socket The intervention of the protection device against overloads is not instantaneous but follows a current overload time outline the greater the overload the less the intervention In case of an intervention check that the current absorbed by the load does not exceed the protection s nominal operating current Allow the protection to cool off for a few minutes before resetting by pressing the central pole m gt n 25 Do not keep the central pole on the thermic protection forcefully pressed to prevent its intervention DELIVERED POWER For each auxiliary voltage it is possible to draw the rated power declared on the data plate Delivering rated for a definite auxiliary voltage it is not possible to draw further
51. r other plants shown both in the data plate and on page named technical data in this same manual Maximum leaning of the machine in case of dislevel 10 20 max 10 26 11 99 M2 6GB 90 90 92 g A OS deeg EX a mw y Y Ze uu i mq Na gt O A ich Ee A Eau K VAN C VS See ANS A FAY We Y M gt Lesch TS 200 DES EL TS 200 LDES EL MA EB M1 4 LU CE Instalaci n o K N B n i o c N S es 0 Installation Installation MOSA REV 3 11 11 TS 200 LDES EL TS 200 DES EL Dimensioni D Abmessungen M D CA Dimension Dimensiones REV 0 11 11 Dimension HEAR n YT IL g a 1280 780 TS 200 DES EL TS 200 LDES EL 26 05 05 27292 l UNPACKING t Be sure that the lifting devices are correctly mounted adequate for the weight of the machine with it s pack aging and conforms to local rules and regulations When receiving the goods make sure that the product has not suffered damage during the transport that there has not been rough handling or taking away of parts contained inside the packing or in the set In case you find damages rough handling or absence of parts envelopes manuals etc we advise you to inform immediately our Technical Service i iE TH For eliminating the packi
52. s and generating sets The certifying institute ICIM which is a member ofthe International Certification Network IQNet awarded the official approval to MOSA after an examination of its operations at the head office andplant in Cusago MI Italy This certification is not a point of arrival but a pledgeon the part of the entire company to maintain a levelof quality of both its products and services whichwill continue to satisfy the needs of its clients aswell as to improve the transparency and thecom munications regarding all the company s activesin accordance with the official procedures and inhar mony with the MOSA Manual of Quality CISQ is a member of ICIM CERTIFICATO n 0192 5 CERTIFICATE No SI CERTIFICA CHE IL SISTEMA DI GESTIONE PERL ALITA DI WE HEREBY CERTIFY THAT THE QUALITY MANAGEMENT SY ST TEM OPERATED BY BCS S p A UNITA OPERATIVE OPERATIVE UNITS Sede e Unit Operativa Viale Mazzini 161 20081 Abbiategrasso MI Unit Operative Via Valbrina 17 19 42045 Luzzara RE Viale Europa 59 20090 Cusago MI Italia E CONFORME ALLA NORMA IS IN COMPLIANCE WITH THE STANDARD UNI EN ISO 9001 2008 PER LE SEGUENTI ATTIVITA FOR THE FOLLOWING AC TIVITIES EA 18 Progettazione produzione ed assistenza di trattori macchine per agricoltura e manutenzione del verde motosaldatrici e gruppi elettrogeni Design production and servicing of tractors agricultural and green maintenance machines engine
53. safety and or for industrial checks Peapol who for instance use pace maker hearing aid for deaf or something and else Devices used for rating and measuring The immunity of other devices in the operation area of the welder Make sure that other used devices are compatible If it is the case provide other additional measures of protection The daily duration of the welding time po Make sure that the area is safe before starting any welding operation Do not touch any bare wires leads or contacts as they may be live and there is danger of electric shock which can cause death or serious burns The electrode and welding cables etc are live when the unit is operating Do not touch any electrical parts or the electrode while standing in water or with wet hands feet or clothes nsulate yourself from the work surface while welding Use carpets or other insulating materials to avoid physical contact with the work surface and the floor Always wear dry insulating glovers without holes and body protection Do not wind cables around the body Use ear protections if the noise level is high Keep flamable material away from the welding area Do not weld on containers which contain flamable material Do not weld near refuelling areas Do not weld on easily flamable surfaces Do not use the welder to defrost thaw pipes Remove the electrode from the electrode holder when not welding Avoid inhalin
54. the level indicated on the filter i FUEL Do not smoke or use open flames during refuelling operations in order to avoid explosions or fire hazards Fuel fumes are highly toxic carry out operations outdoors only or in a well ventilated environment Avoid accidentally spilling fuel Clean any eventual leaks before starting up motor Refill the tank with good quality diesel fuel such as automobile type diesel fuel for example For further details on the type of diesel fuel to use see the motor operating manual supplied Do not fill the tank completely leave a space of approx 10 mm between the fuel level and the wall of the tank to allow for expansion In rigid environmental temperature conditions use special winterized diesel fuels or specific additives in order to avoid the formation of paraffin e GROUNDING CONNECTION The grounding connection to an earthed installation is obligatory for all models equipped with a diffe rential switch circuit breaker In these groups the generator star point is generally connected to the machine s earthing by employing the TN or TT di stribution system the differential switch guarantees protection against indirect contacts In the case of powering complex installations re quiring or employing additional electrical protection devices the coordination between the protection devices must be verified For the grounding connection use the terminal 12 comply to local an
55. the safety norms in force for which it is advisable to use all these devices or information so that the use does not bring damage to persons or things While working it is advisable to keep to the personal safety norms in force in the countries to which the product is destined clothing work tools etc Do not modify for any motive parts of the machine fastenings holes electric or mechanical devices others if not duly authorized in writing by MOSA the responsibility coming from any potential intervention will fall on the executioner as in fact he becomes maker of the machine t Notice this manual does not engage MOSA who keeps the faculty apart the essential characteristics ofthe model here described and illustrated to bring betterments and modifications to parts and accessories without putting this manual uptodate immediately Z 10 10 02 M 1 1 GB RE D MOS A 6 ce mark EN REV 5 03 11 Any of our product is labelled with CE marking attesting its conformity to appliable directives and also the fulfillment of safety requirements of the product itself the list of these directives is part of the declaration of conformity included in any machine standard equipment Here below the adopted symbol CE marking is clearly readable and unerasable and it can be either part of the data plate V le Europa 59 20090 CUSAGO MI ITALY p EE htp wewmossit et infosmosait ER 0 ES tel 39 029035
56. the maintenance requiring their removal is complete MOVING e Use suitable tools and clothes PARTS can injure See pag M1 1 NOTE By maintenance at care of the utilizer we intend all the operatios concerning the verification of mechanical parts electrical parts and of the fluids subject to use or consumption during the normal operation of the machine For what concerns the fluids we must consider as main tenance even the periodical change and or the refills eventually necessary Maintenance operations also include machine cleaning operations when carried out on a periodic basis outside of the normal work cycle The repairs cannot be considered among the main tenance activities i e the replacement of parts subject to occasional damages and the replacement of electric and mechanic components consumed in normal use by the Assistance Authorized Center as well as by MOSA The replacement of tires for machines equipped with trolleys must be considered as repair since it is not de livered as standard equipment any lifting system The periodic maintenance should be performed accor ding to the schedule shown in the engine manual An optional hour counter M is available to simplify the determination of the working hours N IMPORTANT In the maintenance operations avoid that polluting substances liquids exhausted oils etc bring damage to people or things or can cause negative effects to surroindings health
57. ts has implemented and maintains a Quality Management System which fulfills the requirements of the following standard ISO 9001 2008 Issued on 2010 10 19 Validity date 2012 03 05 Registration Number IT 3722 Gianrenzo Prati President of CISQ ANCE Mex APCER Po sio CCC Cyprus ublic Cro Cert Croatic DOS Holding GmbH Ge ny DS Denmari k vela HKQAA Hong Ko ng Chin a ICONTEC C 2 nbi ia IMNC Mexico JQA Japar ea MSZT Hungary Nemko AS No NSAI Ireland sia SII Israel SIQ Slovenia SIRIM RAS Internatic Ge ia SOS Switzerland SRAC Romania TEST rd Russia TSE Turkev YUQS Ser e sented in the U SA by AFNOR Ce ortific ation CISQ DOS Holding G and NSAI Inc alid at the time of issue of this certificate Updated information is available under www ignet certification co K Net e Michael Drechsel President of IONET IQNet Partners AENOR Spain AFNOR Certification France AIB Vingotte Internatio onal Belgiu CISQ Italy CQC China CQM China COS Czech Kr ELOT Greece FCAV Brazil SE A Ver Inspecta Certification Finland IRAM Arg PCBC Poland Quality Austria Austria RR Rus IQNet is The list of IQNet partner g gr my gt Tia H A E2Net ICIM I ISO 9001 2008 Cert 0192 UNI EN ISO 9001 2008 MOSA has certified its quality system according to UNI EN ISO 9001 2008 to ensure a constant highquality of its products This certification covers thedesign production and servicing of engine dri venwelder
58. vable as well as fixed You must remember that in case you have difficulties for use or installation or others our Technical Service is always at your disposal for explanations or interventions The manual for Use Maintenance and Spare Parts is an integrant part of the product It must be kept with care during all the life of the product In case the machine and or the set should be yielded to another user this manual must also given to him Do not damage it do not take parts away do not tear pages and keep it in places protected from dampness and heat You must take into account that some figures contained in it want only to identify the described parts and therefore might not correspond to the machine in your possession INFORMATION OF GENERAL TYPE In the envelope given together with the machine and or set you will find the manual for Use Maintenance and Spare Parts the manual for use of the engine and the tools if included in the equipment the guarantee in the countries where it is prescribed by law Our products have been designed for the use of generation for welding electric and hydraulic system ANY OTHER DIFFERENT USE NOT INCLUDED IN THE ONE INDICATED relieves MOSA from the risks which could happen or anyway from that which was agreed when selling the machine MOSA excludes any responsibility for damages to the machine to the things or to persons in this case Our products are made in conformity with
59. ving disinserted the voltage No smoking It is prohibited to smoke while filling the tank with fuel No welding Mr It is forbidden to weld in rooms containing explosive gases ADVICE No harm for persons and things Use only with safety tools adapted to the specific use It is advisable to use tools adapted to the various maintenance works Use only with safety protections specifically suitable P Itis advisable to use protections suitable for the different welding works Use only with safety protections ws Itis advisable to use protections suitable for the different daily checking works Use only with safety protections it is advisable to use all protections while A shifting the machine Use only with safety protections It is advisable to use protections suitable for Su the different daily checking works and or of maintenance 26 11 99 M2 1GB CD IMI E A amp INSTALLATION AND ADVICE BEFORE USE GE MS TS BS MOSA 1 0 06 00 A The installation and the general advice concerning the operations are finalized to the correct use of the ma chine in the place where it is used as generator group and or welder Stop engine when fueling Do not touch electric devices if you are barefoot or with wet Do not smoke avoid flames sparks or electric tools when fueling clothes Unscrew the cap slowly to let out the fuel vapours Always keep off leaning sur Slowly unscrew the cooli
Download Pdf Manuals
Related Search
Related Contents
Yamaha 45N12 Data Sheet BENDIX BW7258 User's Manual Bürstsauger/ Carpet vacuum cleaner Introdução Criando um protótipo Manual de Servicio - Diagramasde.com Sony HDR-XR160 Marketing Specifications ダウンロード(PDF 10.7MB) ISW-514PSF - PLANET Technology Corporation. 末端水質監視設備設置工事 特記仕様書 Copyright © All rights reserved.