Home
        Instruction Manual
         Contents
1.  outlet power bar above the dryer for the  LintAlert to plug into     LED Display During Calibration    gm    means no pressure was observed  either due to dryer not  ON  tubing not connected or LintAlert was plugged in with  tubing connected and dryer running  In the latter case   Factory Reset  see below     COM Means too much pressure was present  likely the exhaust  duct was never cleaned or there still exists blockage of some  sort  e g   inefficient vent hood     COCEE means calibration was successful and after 2 seconds the  first LED will illuminate    Monitoring Mode     Io   gt  gt  dryer not ON or tubing detached    EOT normal  recent calibration   m   WHET approx  32  blocked  ree    HHEH approx  60  blocked     Restore to Original Calibration Level  Unplug the unit for 3 seconds  and insert back into plug     Factory Reset  With dryer off  unplug LintAlert then plug back in while  pressing button and continue to hold till chime is heard  approx  2 secs      T approx  20  blocked   approx  45  blocked           Additional troubleshooting guides and updated manuals can be found online   See FAQs online and on the product packaging     Version 8 5          Poke 1   4    hole in flex hose near  dryer connection     Figure 2    Insert tap fitting and assemble  related parts              Connect tubing between tap  fitting and alarm module     Incorrect   Correct          Cut tubing length to minimize  any sag  Proceed to calibrate  unit  step 5      
2.  running  press and hold the LintAlert  button for about 6 seconds  until all five LEDs progressively light  up and you hear a chime tone  records    clean value    pressure  level   After about 2 seconds  you should observe that the first green  LED is illuminated and the logo lens     LintAlert     is steady blue  Note   Any subsequent calibration attempts will require an approximate 12  second press of the button  The LintAlert should now be in a normal  monitoring mode  Refer to the troubleshooting section of this manual  or online if this normal state is not observed     Troubleshooting Section    Notice  Works on all dryers except those with booster fans  dual motor  technology and dryers that share exhaust systems like those typically found  in high rise structures     Tubing does not reach  The tubing can be extended or replaced with  similar diameter tubing  We offer longer tubing lengths in our online  store  but the same tubing  1 8 ID 1   4    OD  is usually available at  aquarium or pet outlets  Results with lengths up to 24 feet were shown  to be consistent  It is important that the tubing placement and type of  tubing prohibit being pinched or kinked     No 110v outlet near my dryer  In most cases  the washer and dryer  reside side by side  and the washer uses 110v  If the washer outlet is  hidden or too far from the dryer   s location  then the first suggestion is  to extend the tubing  see above   The second alternative would be to  purchase and mount a multi
3. LINT  LERT    Monitor and Detect Lint Build up  in Your Dryer Duct    LintAlert Model ALRT31 Installation Manual    NOTE  DO NOT RETURN  THIS PRODUCT TO THE STORE     Many problems can be resolved without returning this product to the retailer    If you are unhappy or there are technical issues  please call us at  561 972 8381    Congratulations     Your In O Vate Technologies LintAlert  dryer exhaust monitor is the most advanced  innovative  and effective pressure sensing monitor for the dryer on  the market today  It is designed to provide progressive  notice of airflow blockage in your dryers    exhaust duct     Introduction   The U S  Consumer Product Safety Commission estimates that 15 500 clothes  dryer fires occur in U S  homes annually  averaging about 10 deaths  300  injuries and  85 million in direct property damage  Lint build up and lack of  maintenance is the number one cause of dryer fires  Your LintAlert home  safety device for the clothes dryer can provide a visual indication of how much  additional pressure exists over time due to lint buildup or blockage of some sort  in the duct work between the dryer and the exterior termination vent     How it Works   The LintAlert monitors and displays the back pressure levels found in the exhaust  conduit of the dryer  Pressure levels found in the duct work between the back of  the dryer and the exterior vent hood typically increase over time due to lint build   up or other restrictions like birds nest or vent hoods tha
4. LintAlert will not initialize or may  not initialize correctly if the dryers    exhaust condition is not in a like new clean state   This like new state can be achieved by hiring a professional duct cleaner or doing it  yourself with a dryer vent cleaning kit  These kits are readily available online or at   hardware stores and are comprised of a rotating action auger brush and flexible rods     Technical Support Options   Online  Extensive FAQ   s Available     www lintalert com  Phone  561 972 8381  Email  support lintalert com  Hours  7 am to 11 pm EST  7 Days a Week    Manufactured by   In O Vate Technologies  Inc     810 Saturn Street  Suite 21 Jupiter  FL 33477  US Patent 6 785 981  Others Pending Copyright   2010 In O Vate    Technologies  Inc  All rights reserved  LintAlert is a registered trademark of  In O Vate Technologies  Inc  Proudly made in the U S     Registration   Congratulations on your purchase of the LintAlert    To fully  benefit from the support that In O Vate Technologies offers   please register your product at www lintalert com register htm     Limited Warranty and Service   In O Vate Technologies warrants to the original purchaser that the enclosed dryer  exhaust monitoring system will be free from defects in materials  workmanship or  design under normal use and service for a period of one year from the date of  purchase provided that it is properly used as prescribed by the owner   s guide   The obligation of In O Vate Technologies under this warra
5. nty is limited to  at our  option  repairing or replacing the LintAlert or any part which we find to be defective  in material  workmanship or design  free of charge to the customer provided that  prior to any return  a Return Authorization  RA  number and shipping instructions  are attained by contacting In O Vate Technologies Customer Service     This warranty shall be void if registration is not completed and sent to In O Vate  Technologies  Inc  customer services within 30 days of purchase  This warranty  shall not apply to the LintAlert system if it has been damaged  modified  abused  or altered after the date of purchase or if it fails to operate due to improper  maintenance or problems caused by inadequate A C  electrical power or power  fluctuations     THE LIABILITY OF IN O VATE TECHNOLOGIES OR ANY OF ITS PARENT  OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS  DRYER EXHAUST MONITORING DEVICE OR UNDER THE TERMS OF THIS   LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF  REPLACEMENT OF THE LINTALERT MONITORING DEVICE AND  IN NO  CASE  SHALL IN O VATE TECHNOLOGIES OR ANY OF ITS PARENT OR  SUBSIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSS  OR DAMAGES RESULTING FROM THE FAILURE OF THE LINTALERT  MONITORING DEVICE OR FOR BREACH OF THIS OR ANY OTHER  WARRANTY  EXPRESS OR IMPLIED  EVEN IF THE LOSS OR DAMAGE IS  CAUSED BY THE COMPANY S NEGLIGENCE OR FAULT  While this warranty  gives you specific rights  you may also have other rights which vary from 
6. rt on the back of the dryer   Favoring the middle to outside radius of the flex  carefully  poke a      hole in the hose  4  6  away from where the exhaust  port connects   Figure 1   Be sure to leave room for the flex hose to  re secure to the dryers    exhaust terminal     Step Three   Take the umbrella shaped tap fitting   Figure 3   A  and slide  it up inside the exhaust hose and through the hole you just  made  It is important to rotate the fitting so that the curved  contour of the fitting matches that of the transition hose  The felt washer   B  will go on next  followed by the curved washer  C   Finally  twist the  nylon thumb nut on and finger tighten to ensure that no air can escape   Figure 4   Connect one end of the clear vinyl tubing to the tap fitting   while supporting it from within the flex hose  and reattach the existing  exhaust hose to the dryer   s exhaust port     og BDB    Step Four   Move the dryer back into place and plug the alert module  into the nearest un switched 110v AC power outlet prior  to attaching the tubing to the barb  Important Note  Cut  the length of the clear vinyl tubing to minimize any sag or droop in the  tubing  as this could allow condensation build up within the tubing to  puddle thus creating an air block  Figure 5   Insert tubing over hose  barb on LintAlert     Step Five  Calibration    Clean the dryer   s lint screen  Begin a drying cycle with NO  clothes in the drum and at your usual temperature setting   While the dryer is
7. state to  state  Since some states do not allow limitations on the duration of an implied  warranty or do not allow the exclusion or limitation of incidental or consequential  damages  the above limitations or exclusions may not apply to you     If  after reviewing this manual  you feel that your LintAlert dryer exhaust  monitoring device is defective in any way  do not tamper with the unit or return it  to the store you bought it at  Obtain customer or technical service in the U S  or  Canada  by calling In O Vate Technologies at 561 972 8381  THIS IS IN O VATE  TECHNOLOGIES COMPLETE WARRANTY FOR THE PRODUCTS  The above  warranty may not be altered except in writing by In O Vate Technologies     Installing the LintAlert    Installation and calibration is a fairly quick and straight forward process     Step One   Confirm that the in the wall duct system has been  completely cleaned and in like new condition  read  Notice on reverse side    In O Vate Technologies  as  well as the leading dryer manufacturers  strongly recommend using a  transition hose that is UL2158A listed  like DryerFlex    or semi rigid  aluminium flex  The wire bound foil flex  although not as efficient  will  work comparably with the LintAlert  If you have white vinyl flex  please  take this opportunity to replace it  as it s been well documented to be  extremely unsafe and associated with many dryer fires     Step Two   Disconnect the new or existing exhaust hose from where  it connects to the exhaust po
8. t become inoperable  The  LintAlert incorporates a very innovative and responsive digital low differential air  pressure sensor  Coupled with a smart programmable integrated microprocessor   the device can determine if your dryer is running  and what levels of pressure  exist  When the pressure level reaches a point that is unsafe the    alarm state     will indicate its time to clean out the duct work  Prior to the alarm state  a slow  progression of the LED light bar will indicate fractional build up     Before You Begin  Items in Package    Please review the parts and make sure they are present  Refer to the Installing   the LintAlert section for proper installation    1  Alert Module  the plug in component that contains the electronics and air  pressure sensor  120V 60Hz 15 AMPS max pass through      2  Tap Fitting  four pieces  2a  umbrella shaped tap fitting  2b  felt washer  2c   curved washer and 2d  nylon thumb nut     3  Tubing  approximately 6 feet of 1 8    inside diameter by 14  outside diameter clear  vinyl PVC        NOTICE  Please Read This Prior to Calibrating the LintAlert    In_order for the LintAlert to accurately monitor the air  ressure levels in your specific dryer duct system and warn   of any unsafe levels  the device needs to be calibrated to your  articular system at a LIKE NEW or VERY CLEAN STATE                 In technical terms  the clean pressure value must be recorded to memory in order to  provide an accurate scale of build up intervals  The 
    