1. MiNePort E1 00 90 E8 14 F 7 99 192 168 127 254 Figure 3 NPSU s Search window Firefox v MiiNePort Web Console 192 168 127 254 amp Main Menu Overview H Basic Settings Model name MiiNePort E1 Serial No 9976 chm Device name MiiNePort E1 9976 I Maintenance Firmware version 1 1 Build 09072414 Save and Restart Ethernet IP address 192 168 127 254 Welcome to MiiNePort E1 web console HL Advanced Settings Ethernet MAC address 00 90 E8 1A F7 99 Up time 0 days 00h 41m 32s Serial communication Sore Data Mode Figure 4 The MiiNePort web console DDNNO004MHGB 09 2015 Rev 1 6 Installation user and maintenance manual Ethernet module Step 4a mandatory The left side of the web console contains a tree menu for all settings The following settings should be set for correct operation Basic Settings gt gt Serial Port Settings e Port Alias Can be left blank e Baud rate Should be set to 9600 e Data bits Should be set to 8 e Stop bits Should be set to 7 e Parity Should be set to None e Flow control Should be set to None or RTS CTS FIFO Should be set to Enable Press Submit to save the settings Ignore the message that appears and go to the Operation Modes Basic Settings gt gt Operation Modes e Mode Should be set to TCP e Role Should be set to TCP Server e Local TCP port Free to choose Press Submit again and in the next screen press Save
2. The module is connected to an Ethernet network via an RJ 45 connector If applicable the connector should be crimped to the cable after putting the cable through one of the cable glands The cable gland must be well tightened DDNNOO4MHGB 09 2015 Rev 1 3 Installation user and maintenance manual Ethernet module 3 Status indicators and connections Figure 2 Connector and LED on the Ethernet module LED indicator for powered on 2 LED indicator for network activity Green 100BASE TX link blinking indicates data transfer Red 10BASE T link blinking indicates data transfer 3 RJ45 connector for connection to Ethernet 4 LED indicator for connected status Green Constant on if connected Red Fault blinks if an IP fault occurs or when the module is resetting DDNNOO4MHGB 09 2015 Rev 1 4 Installation user and maintenance manual Ethernet module 4 UNIGAS settings Some settings in UNIGAS are needed if it is to be used with the ISC230B and Ethernet module These settings may have been factory set 4 1 UNIGAS 61 E Service software CONVERTER TOOL Communication Interface screen tab page Schedule At interface quit mode tick 4 2 UNIGAS 300 ISC230B connected to optical port 1 of UNIGAS 300 Service software UNITOOL menu System information UNITOOL menu Modem Configuration C 93 12 Modem schedule set to module 0 ISC230B connected to optical port 2 of UNIGAS 300 To use optical port 2 of UNIGAS 300
3. and maintenance manual Ethernet module 1 Introduction The Ethernet module is a module that can be used in all mains supplied models of ISC230 SC230 and ISC230B Article code NN2566 The module is designed to be plug and play once powered the embedded microcontroller takes care of all needed settings on the modem module part When used in installations with an UNIGAS electronic volume converter settings to the UNIGAS are needed for proper operation See chapter 4 UNIGAS settings 2 Installation 2 1 Installing the module components if no precautions are taken ESD is caused by static electricity Fa Electrostatic discharges ESD can cause damage to internal electrical ESD and the damage caused is usually permanent Some of the components in the device in which the PSTN module is to be WARNING installed are connected to the mains voltage Switch off the mains voltage prior to performing these activities See the user manual for the device in which the G485B module is to be installed Depending on the device in which the Ethernet module is to be installed this will take place as follows e I 5C230 and SC230 see label on the left of the casing connect the Ethernet module to the free connector e SC230B see label on the left of the casing there are three connectors present There may already other modules be installed Connect the Ether module to a free connector 2 2 Connecting the equipment to a Ethernet network
4. 15 Rev 1
5. Installation and user manual Ethernet module Wigers i Sikkem Installation user and maintenance manual Ethernet module All rights reserved Copyright 2015 Wigersma amp Sikkema B V NL 6980 AC Doesburg All the figures and descriptions in this installation operating manual have been compiled only after careful checking Despite this however the possibility of errors cannot be completely eliminated Therefore no guarantee can be given for completeness or for the content Also the manual cannot be taken as giving assurance with regard to product characteristics Furthermore characteristics are also described that are only available as options The right is reserved to make changes in the course of technical development We would be very grateful for suggestions for improvement and notification of any errors etc With regard to extended product liability the data and material characteristics given should only be taken as guide values and must always be individually checked and corrected where applicable This particularly applies where safety aspects must be taken into account You can obtain further support from the branch or representative responsible for your area You will find the address on the back of this manual or simply enquire at Wigersma amp Sikkema B V Passing this manual to third parties and its duplication in full or in part are only allowed with written permission from Wigersma amp Sikkema B V The guar
6. Restart The red LED on the MiiNePort will start blinking to indicate that it is restarting Step 4b optional The settings in step 4a are limited to the absolute minimum needed for correct operation you are free to look into the other settings in the web console It is advisable to add a password to the console via maintenance gt gt Change Password for increased protection Step 5 If all steps were followed correctly you should be able to use the module for instance with UNITOOL DDNNOO4MHGB 09 2015 Rev 1 7 Installation user and maintenance manual Ethernet module 6 Maintenance The Ethernet module does not require maintenance For the maintenance of the equipment in which the modules are installed please see the user manual for the equipment in question 7 Technical specifications e Status indicators Red LED for Powered and 2 Indicators on the Ethernet module e Connections RJ 45 with magnetics and 20 pin angled socket e Operating temperature 40 to 85 C e Operating current Idling 10 mA 12V Connected 50 mA 12V e Integrated Ethernet module Moxa MiiNeport E1 See www moxa com for more information about MiiNeport E1 DDNNOO4MHGB 09 2015 Rev 1 8 wig ersma Sikkem Wigersma amp Sikkema B V Postbox 109 6980 AC Doesburg Leigraafseweg 4 6983 BP Doesburg TEL 31 0 313 47 19 98 FAX 31 0 313 47 32 90 info wigersma sikkema com www wigersma sikkema com DDNNOO4MHGB 09 20
7. a module must be installed in UNIGAS 300 to activate port 2 Contact Wigersma amp Sikkema if this is required No settings are needed DDNNOO4MHGB 09 2015 Rev 1 I Installation user and maintenance manual Ethernet module 5 Setting up the TCP server of the MiiNePort E1 The following steps explain setting up the TCP server on the MiiNePort E1 which is embedded on the Ethernet module Step 1 Install Moxa s NPort Search Utility NPSU this program can be downloaded free of charge at http www moxa com support sarch result aspx prod id 539 amp type id 5 amp type soft This program can be used to identify Moxa devices on a network Step 2 In NPSU press Search ctrl B a window will appear in which all found Moxa devices will be listed see fig 3 The Stop button could be pressed after the MiiNePort E1 has been found to stop searching searching will automatically stop after 10 seconds The search window will disappear once searching has finished this will bring you back to NPSU s main window Step 3 In the main window double click the line of the MiiNePort This will bring you to the embedded web console of the Ethernet module see fig 4 It is also possible to select the MiiNePort E1 and press the Console button in the main window Searching Searching for NPort I Show IPv6 Address Found 1 NPort s 9 second s left No Model LANT MAC Address LAN1 IP Address LAN2 MAC Address LAN2 IP Address
8. antee becomes invalid if the product described here is not handled properly repaired or modified by unauthorised persons or if replacement parts are used which are not genuine parts from Wigersma amp Sikkema B V Preface m This manual provides important information Read this manual carefully E Various observations and warnings are marked in this manual by means of symbols Read these carefully and take measures if necessary The symbols used have the following meaning OBSERVATION Suggestions and recommendations to facilitate task performance AN PLEASE NOTE An observation alerts the user to possible problems WARNING If the action is not implemented correctly data or settings may be lost ESD An observation alerts the user to take measures for ESD DDNNOO4MHGB 09 2015 Rev 1 1 Installation user and maintenance manual Ethernet module Table of contents Pee 1 1 MOAUCUON ae 3 2 MENS VAM AUTO 2 3 2 1 is Fald TE MOTE PES 3 2 2 Connecting the equipment to a Ethernet network ccccccecccssessseceeeeeeeaeeesseeceeeeseaeeaseeeeeeeeesaaaaeses 3 3 Status indicators and CONNECUONS ivicivesiciscsscteccaectaceinertncetacetineetvectiecteeetwecveectwcctecet 4 A UNIGAS SIS arve 5 AM MESEN 5 AB NS NE 5 5 Setting up the TCP server of the MiiNePort Ef rrvnnnvrnnnnvrnnnuvennnnvrnnnnevnnnuennnnvennnnuern 6 INIAINTONAN GCC aa 8 7 Technical specifications sad 8 DDNN004MHGB 09 2015 Rev 1 2 Installation user