Home

AIRE Plus 8350 User Manual

image

Contents

1. 50 Hz 1 0 A EU Model 8353 230 VAC 50 Hz 1 0 A UK Type B E Class Il IPXO off on ACCESSORIES Model Description 8501 Replacement Air Filters 5 per pkg 8504 Replacement Air Filter Cap 1 each 8660 NebuTech HDN Nebulizer 7 Tubing Reusable 8900 Nebulizer with Tee Adapter 7 Tubing Mouthpiece and Reservoir Tube 8906 Nebulizer Pediatric Mask 7 Tubing 8924 Nebulizer Adult Mask 7 Tubing 8960 NebuTech HDN Nebulizer 7 Tubing Disposable 8966 NebuTech HDN Nebulizer Pediatric Mask 7 Tubing 8984 NebuTech HDN Nebulizer Adult Mask 7 Tubing 8258 Compressor Carrying Bag Page 8 of 9 WARRANTY Salter Labs warrants the SALTER AIRE PLUS Compressor to be free from defects in workmanship and materials for a period of five years from the date of purchase Check with your dealer for more details This warranty is limited to the original purchaser of the compressor Any defective part or assembly will be repaired or replaced at the sole discretion and determination of Salter Labs if the unit has not been misused or tampered with during the period Normal maintenance items and disposable components are not covered by this warranty Shipping charges if any shall be paid by the purchaser THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE EXPRESS LIMITED WARR
2. ANTY AND TO THE EXTENT PERMITTED BY LAW AND ANY OTHER IMPLIED WARRANTIES ARE EXCLUDED THIS WARRANTY DOES NOT COVER PROVIDING A LOANER COMPRESSOR COMPENSATING FOR COSTS INCURRED FOR COMPRESSOR RENTAL OR FOR LABOR COSTS INCURRED IN REPAIRING OR REPLACING A DEFECTIVE PART S Thank you for selecting the SALTER AIRE PLUS Compressor Salter Labs is an innovative industry leading manufacturer of respiratory care devices Please contact your local Salter Labs dealer for information about additional products E SALTER LABS 100 W Sycamore Road Arvin California 93203 USA Tel 661 854 3166 800 421 0024 800 235 4203 Fax 661 854 3850 800 628 4690 Internet www salterlabs com Authorized Representative in the E U MT Promedt Consulting GmbH Altenhofstrasse 80 D 66386 St Ingbert Germany 0482 Salter Labs Salter Aire Plus NebuTech and the Salter Labs logo are trademarks of Salter Labs 801562 Rev F Page 9 of 9
3. EJ SALTER LABS SALTER AIRE Plus COMPRESSOR Model 8350 8352 8353 Instruction Manual TABLE OF CONTENTS INTTOGUCHoNs eil snai 3 IMporantsaleguatdS ias 3 System ComponeiSqussiaican aaa dar 5 Mor pe 0 1 O 5 LUD PECES CU 5 E bade awe aan sew a EN 5 A e O UI O 6 Cleaning and Storage siseringi anaa ieaie 6 Compressor UI elle 6 Nebulizer AAA e ES O o ARA ee 7 o CO rina 7 Ml A celta ste ah ater eta air 7 Fiter Chandler eee ee a clea aed 7 TON 7 SPECICATION Susi 8 ACCOSSOMES ra iia 8 A eet cia ea Get enn ae ane iodio 9 DEVICE INFORMATIONS Record the following information for easy reference regarding your SALTER AIRE PLUS Compressor Physician Name Physician Phone Dealer Name Dealer Phone Purchase Date Page 2 of 9 INTRODUCTION Your physician has prescribed a liquid medicine to treat your respiratory condition In order to ensure high quality aerosol nebulization they have prescribed the SALTER AIRE PLUS Compressor system from Salter Labs The SALTER AIRE PLUS Compressor generates compressed air to turn your liquid medication into an aerosol mist that penetrates into your lungs Used in conjunction with a nebulizer supplied by Salter Labs you can be assured that you are using the finest quality products to deliver your medication To maximize your benefit from the SALTER AIRE PLUS system it is important for you to read and understand the information in this instruction manual By followin
4. P 1 Remove the compressor from its optional carrying case Place the compressor on a level sturdy surface Make sure you can reach the controls when seated Press the power switch to the off position Page 5 of 9 CAUTION Never block the air vents on the rear and bottom of the device or place it where the vents may be blocked Make sure there is at least 15 cm 6 in clearance on all sides of the unit Plug the power cord into a power outlet Unpack the Salter Labs nebulizer and connect one end of the tubing to the compressor s outlet 4 Assemble the nebulizer according to its instructions Make sure that the green cone has been placed into the nebulizer cup before assembling the top to the cup CAUTION Do not use a nebulizer if its green cone is missing Utilize a new nebulizer if necessary 5 Add the prescribed liquid medication to the top of the nebulizer using an eyedropper premeasured unit dose or ampoule 6 Attach the mouthpiece to the nebulizer 7 Connect the tubing to the bottom inlet on the nebulizer OPERATION 1 Press the power switch to the on position to start the compressor 2 Observe the nebulizer as the air flow begins If you cannot visually observe an aerosol mist coming out of the nebulizer replace it with another Salter Labs nebulizer 3 Begin treatment by placing the nebulizer mouthpiece between your teeth Close your mouth Inhale deeply and slowly as the aerosol begins to flow Hold y
5. essary 1 Using a large coin unscrew the filter cap on the front panel and pull it out 2 Remove the filter from the filter cap 3 The filter should be changed if significant discoloration is noticed around the middle of the filter or when it begins to turn brown or gray in color If required insert a new filter in the filter cap and discard the dirty filter Otherwise reinsert the existing filter in the filter cap 4 Screw the filter cap into position CAUTION Compressor damage may result if filters are reused or substituted with any other material SERVICE Except for instructed user maintenance all device servicing must be performed by a Salter Labs authorized service representative There are no user serviceable parts Page 7 of 9 inside the unit Contact your Salter Labs dealer or authorized service center if your unit needs repair WARNING Do not tamper with or attempt to repair the device Refer servicing to qualified service personnel SPECIFICATIONS Specifications and appearance are subject to change without notice Dimensions 17 0 cm L x 14 5 cm W x 11 2 cm H 6 7 Lx 5 7 Wx 4 4 H Weight Model 8350 1 8 kg 4 0 Ib Model 8352 1 9 kg 4 2 Ib Model 8353 2 1 kg 4 6 Ib Free Flow 10 Ipm minimum Pressure 25 psi minimum Liter Flow 6 lpm minimum through a Salter Labs nebulizer Ambient Temperature 10 to 40 C 50 to 104 F Electrical Model 8350 115 VAC 60 Hz 1 9 A Model 8352 230 VAC
6. g your doctor s advice and these simple instructions your SALTER AIRE PLUS system will become a valuable part of your daily treatment routine CAUTION Use only as prescribed by your physician with the prescribed medication Read all warnings and instructions before use Improper use can result in serious or fatal illness or injury CAUTION Use only with nebulizers masks and tubing supplied by Salter Labs Other nebulizers masks and tubing may result in improper treatment One nebulizer is provided with the compressor Contact your local dealer to obtain additional Salter Labs nebulizers CAUTION Federal law USA restricts this device to sale by or on the order of a physician IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USING When using this electrical device especially when children are present basic safety precautions should always be followed including the following precautions DANGER To reduce the risk of electrocution Always unplug the device immediately after using Do not use while bathing Do not place or store the device where it can fall or be pulled into a tub or sink Do not place in or drop into water or other liquid Do not reach for a device that has fallen into water Unplug immediately WARNING To reduce the risk of injury Use this device only for its intended use as described in this manual Use only with nebulizers supplied by Salter Labs Close supervision is necessa
7. is turned off and unplugged 2 Disconnect tubing from the compressor and the nebulizer Set the tubing aside 3 Disassemble and clean the nebulizer according to its instructions 4 After cleaning reassemble the nebulizer and tubing Make sure that the green cone is placed into the nebulizer cup before assembling the top to the cup WARNING To prevent possible risk of infection due to contamination clean the nebulizer after each use according to the instructions STORAGE 1 Place the tubing and nebulizer in a clean dry sealed container or bag 2 Coil the power cord 3 Store the compressor and nebulizer kit in a clean dry environment If available store and transport the device and accessories in its carrying case Do not store the compressor on the floor where it can collect dust NOTE The Compressor should be stored and transported in the following environmental conditions Ambient temperature 40 to 70 C 40 to 158 F Relative humidity 10 to 100 Atmospheric pressure 500 to 1060 hPa 375 to 795 mmHg MAINTENANCE FILTER CHANGE Your SALTER AIRE PLUS Compressor has an inlet air filter to remove airborne contaminants The filter requires periodic replacement The compressor comes with a package of extra inlet filters for this purpose Contact your local Salter Labs dealer to obtain additional filters Check the inlet filter at least once a month Follow these steps to check and replace the filter if nec
8. our breath for several seconds then exhale slowly 4 If a Salter Labs aerosol mask is being used position the mask over your nose and mouth Inhale deeply and slowly through your mouth as the aerosol begins to flow Hold your breath for several seconds then exhale slowly 5 Continue treatment until aerosol mist is no longer coming out of the nebulizer Press the power switch to the off position to turn the compressor off Remove and clean the nebulizer according to its instructions CAUTION In high humidity conditions water buildup can occur in the compressor tubing If this occurs turn the compressor on and run it for several minutes before connecting the medication container CAUTION Cold temperature may result in poor compressor performance Allow the unit to warm to room temperature for best results CLEANING AND STORAGE COMPRESSOR CLEANING In order to maintain its performance clean your SALTER AIRE PLUS Compressor every two to three days 1 2 Ensure that the compressor is turned off and unplugged Wipe the compressor with a clean damp cloth This will keep the unit dirt and dust free CAUTION Do not spray any fluid into the air vents of the compressor Fluids may cause damage to internal components and could lead to a malfunction Page 6 of 9 NEBULIZER CLEANING Clean the nebulizer after each use Refer to the cleaning instructions supplied with your nebulizer 1 Ensure that the compressor
9. rgy and if not installed and used in accordance with these instructions may cause harmful interference to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to other equipment which can be determined by turning the device off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving device Increase the separation between the equipment Connect the device to an outlet on a circuit different from that which the other device s are connected Consult your Salter Labs dealer or authorized service center for help NOTE The compressor employs an automatic reset thermal limiter that shuts off the entire device if the motor overheats The compressor will restart when the motor cools to an acceptable level SAVE THESE INSTRUCTIONS Page 4 of 9 SYSTEM COMPONENTS aie son o A a Salter AIRE Piys ETT Lang j SETUP AND OPERATION Follow these simple steps to prepare your SALTER AIRE PLUS Compressor for operation The instructions below describe use with a nebulizer If an aerosol mask is to be used follow the assembly instructions that come with the mask NOTE Always wash your hands before you begin treatment NOTE Always have at least two Salter Labs nebulizers on hand available for use SETU
10. ry when this device is used by on or near children or invalids Never operate this device if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water Return the device to a service center for examination and repair Turn the compressor off before filling the nebulizer with medication Page 3 of 9 To prevent possible risk of infection due to contamination clean the nebulizer after each use according to its instructions Never block the air vents on the rear and bottom of the device or place it where the vents may be blocked Make sure there is at least 15 cm 6 in clearance on all sides of the unit Do not operate the compressor while it is enclosed in a carrying case or bag If the device abruptly stops operating check that the power cord connection is secure Also see note below Keep the cord away from heated surfaces Never drop or insert any object into any opening or hose Never use this device while sleeping or drowsy Do not use outdoors This device is for indoor use only Do not tamper with or attempt to repair the device There are no user serviceable parts inside the unit Except for instructed user maintenance all device servicing must be performed by a Salter Labs authorized service center Do not use this device in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide This device may generate use and radiate radio frequency ene

Download Pdf Manuals

image

Related Search

Related Contents

Codice FAST: 9218  Fotómetro - Lovibond Tintometer  Accordent Capture Station v4.3 Manual  Open Pulsar User Manual PDF  Chief MTMPU flat panel wall mount  AH-2 - アイコム    Siemens 150 Cell Phone User Manual  Philips Cutter for hairclipper CRP279  

Copyright © All rights reserved.
Failed to retrieve file