Home

SCG-1 User Manual

image

Contents

1. Error Error Likely Root Cause Fix Code Message Error 1 Heater circuit Short in sensor Replace sensor shorted Error 2 Heater circuit 1 Damaged sensor 1 Verify that all sensor open cable or sensor connectors are fully seated and 2 Sensor connector not locked into position fully seated and locked 2 Replace sensor into position 3 Replace sensor cable Error 3 Pump cell 1 Short in sensor 1 Replace sensor cable circuit shorted cable 2 Replace sensor 2 Short in sensor 3 Perform sensor recalibration 3 Sensor calibration incorrect Error 4 Pump cell 1 Damaged sensor 1 Verify that all sensor circuit open cable or sensor connectors are fully seated and 2 Connectors not fully locked into position seated 2 Perform sensor calibration 3 Sensor calibration 3 Replace sensor cable incorrect 4 Replace sensor Error 5 Reference cell 1 Short in sensor 1 Replace sensor cable circuit shorted cable 2 Replace sensor 2 Short in sensor Error 6 Reference cell 1 Damaged sensor 1 Verify that all sensor circuit open cable or sensor connectors are fully seated and locked into position 2 Connectors not fully 2 Replace sensor seated 3 Replace sensor cable Error 7 System error System error Reboot SCG 1 by cycling power Error 8 Sensor 1 Sensor over heating 1 Perform sensor calibration Timing error or over cooling error 2 Move sensor bung as far typically a co
2. The LM Programmer application can be launched from Start gt Programs gt LogWorks3 gt LM Programmer from the Windows task bar 4 2 1 Programming Analog Output Connect the SCG 1 to the computer and launch LM Programmer Select the Analog Output tab The analog output configuration screen shows voltage versus Lambda for the analog output The graph display is automatically scaled to the selected voltages values The configuration screen allows the user to specify a minimum and maximum lambda or A F value to a corresponding voltage range 14 By selecting the use Air Fuel Ratio button you can change the displayed unit of measure for mixture by AFR instead of Lambda This does not change the programming only the unit of measure displayed in the configuration screen Click the Program button to upload your modified A F or lambda scaling data into the SCG 1 Once the unit has been programmed the Program button will grey out Factory Programmed Default The analog output by default is programmed to output between OV at 7 35 AFR to 5 0V at 22 39 AFR Other settings of course are easily programmable 4 2 2 Advanced Analog Output Programming The Advanced button allows the user to set the analog out update speed and the voltage output during sensor Warm up and error conditions The factory defaults of the analog outputs update 1 12 of a second The default voltage output is set at 0 volts for both the Warm up and
3. 0 Tuning Tip Tune your wastegate duty and spring pressure settings before gain Spring Pressure Spring Press Sets the activation pressure for the solenoid Set this value at or less than your mechanical spring pressure Be aware that setting this value too low may cause boost spikes setting it too high may cause an extreme delay in the activation of the solenoid Default setting is 4 9 PSI Tuning Tip A good starting point is 1 to 2 PSI below the wastegate s mechanical spring pressure Boost Cut by Pressure This is a safety trigger to cut boost by a desired wastegate duty percentage at a specific manifold absolute pressure There are two setup parameters to trigger this safely cut Max Pressure Boost Cut Press and Cut Percent Boost Cut Max Pressure Boost Cut Press is the maximum manifold absolute pressure that is safe for the application Cut Percent Boost Cut is the percentage of wastegate duty that the trigger will cut when the max defined pressure is hit When the safety Boost Cut by Pressure is triggered the SCG 1 will display B Cut on the upper right hand corner viewport Default setting is 8 PSI with a 100 cut Tuning Tip Start with a 100 Cut Percentage Boost Cut by AFR This is a safety trigger to cut boost by a defined AFR There are two setup parameters to trigger this safely cut Start Pressure AFR Start Press and AFR Cut Start Pressure AFR Start Press is the minimum manifold absolute p
4. O2 E2 This is an error code indicating that no sensor is detected Leave unit powered on for a minimum of 30 seconds 2 Power down the SCG 1 and attach the oxygen sensor using the cable provided When making these connections make sure they are fully seated and locked Again make sure that the sensor is in free air not in the exhaust 3 Power up the SCG 1 The SCG 1 will start warming up the sensor this is indicated on top right hand corner viewport of the display by showing O2 HTR After 30 60 seconds the display will switch from O2 HTR and quickly flash O2 CAL indicating that the sensor is being calibrated The calibration procedure has completed and the system is now ready for use Important You can disconnect and reconnect the sensor and sensor cable for installation without losing your calibration However if you power up the SCG 1 without a sensor connected your calibration will be reset see step 1 above 2 5 3 Calibration Schedule Turbo Application daily driver tuned rich Calibrate before installation of new sensor Calibrate new sensor again after 3 month of use Thereafter calibrate twice a year or every 10 000 miles whichever comes first Race Application Calibrate before first installation of new sensor Calibrate once per race weekend 3 Boost Controller Setup 3 1 Entering Setup Configuration The SCG 1 can be configured directly from the gauge itself or by con
5. 15 seconds From the main screen pressing and HOLDING both the left and right interface buttons will disable enable solenoid control If there are no other error codes on the status viewport of the screen the SCG 1 will display SC OFF 4 Shift Light Illuminates when the trigger shift RPM is reached 1 1 Changing the SCG 1 s gauge face and or bezel 1 Lay the SCG 1 face down and remove the three 2 phillips screws from the outside rim of the back plate 2 Pull the bezel black ring Thumb must be pressing down upwards to remove on the glass on bezel When disassembling be careful not to lose the clear plastic light pipe from the shift light opening as it can fall out Pulling the bezel upwards while NOT holding the glass down can potentially damage the SCG 1 3 3 Configure the gauge as desired by changing the gauge face and or bezel 4 Make sure every piece is positioned correctly using the locating tab and reassemble the gauge 5 Reinstall the three 2 phillips screws verifying that the buttons are not binding on the gauge lens 2 Installation R sensor c CONNECTO EE SENSOR CABLE CONNECTOR oo CEEI MAP SENSOR I 3 PIN CONNECTOR ir MOUNTING BRACKET P BLACK 5 E RED ai EE JsoLenoin SERIAL IN amp OUT 2 PIN CONNECTOR 4 PIN CONNECTORS 2 1 Wiring The SCG 1 has 5 stripped wire leads 1 Connect the RED wire to an isolated switched 12V sou
6. INNOVAT amp MNO TORS PP ORT S5 SCG 1 User Manual A Warning A The Oxygen Sensor used in this device gets very hot in operation Do not touch a hot sensor Do not let a hot sensor touch a combustible surface Do not use the sensor with or near flammable liquids or gases Failure to heed these warnings may result in severe burns explosions fires or other dangerous events T SGO ecceri a a a a R a NE 2 1 1 Changing the SCG 1 s gauge face and or bezel 3 2 Walla Ones n a Gap ighs scveeacsecaeesesses 4 Balk VINO ceca hteces dace E E A 4 2 1 1 Single Innovate Device Relay Wiring Instructions 5 2 2 Gauge Mounting and Routing 0 ccccceeeeeeceeeeeeeeeeeeeeeceeeeeeeaeeneneeees 6 2 3 Solenoid Installation eecceccceceeeeeeeeeceeeee cece eeeeeeseeeeeseeeesaeeseaeeee 6 2 3 1 Internal Wastegate cccccccessseceeeeeceeeeeecaeeeeeeeseeeeesaeeeeaeeeeeees 6 2 3 2 External Wastegate ccccccecseeceeeee cece eeeeeseeeeeseeeesaeeneaeeeed 7 2 4 MAP SENSO aisiki aana det deia naa aaiae aada anias 7 2 5 Wideband Oxygen Sensor Setup ccecceeeeeeeeeeeeeeeeeceeeeeeseaeeseneeees 7 2 5 1 Oxygen Sensor PlaceMent ccccccceeeeeeeeeeeeeeteeeeetaeeeeeeeees 7 2 5 2 Sensor Calibration ecccccceeeseeeeeceeeeeeeeeeeeseeeeeseeeesaeeseeeee 9 2 5 3 Calibration Schedule eesseesseeeseeeeeeseeessesseeserssnnsrnnssnesnnes 9 3 Boost Controller Setup ectcieiav site
7. c interference noise 2 3 Solenoid Installation Mount the solenoid in a suitable location away from high temperatures or near ignition components Secure hoses with cable ties Make sure not twist or pinch any of the hoses The solenoid will make audible clicking noises when in operation this is normal Route the solenoid cable through the firewall to the gauge and connect to the 2 pin connector Confirm that you do not have any air leaks when the engine idles 2 3 1 Internal Wastegate 2 3 2 External Wastegate 9 a Ok Onl 2 4 MAP sensor 1 The MAP sensor MUST be installed with the hose fitting facing down It is very important that the sensor be isolated from heat sources mounted away from all ignition and or other potential RF emitting sources and protected against excessive vibration The MAP sensor has two 1 8 holes that can be used to secure the sensor Another viable option is to use double sided mounting tape 2 Locate a vacuum source on the intake manifold after the throttle body and connect it to the hose barb on the sensor Use the provided T and hose to make this connection if needed To secure the hose use tie wraps or hose clamps 3 With the engine idling confirm that you do not have any air vacuum leaks 2 5 Wideband Oxygen Sensor Setup 2 5 1 Oxygen Sensor Placement Optim
8. error conditions Advanced Analog Out Settings Response Speed C Instant 1412sec C 1 6 sec C 1 3 sec Output at Error Cond 0 00 Yolt or Warmup output 0 00 oltor T High Impedance T High Impedance Factory defaults A GI When setting the SCG 1 to the slower response speed settings the measured mixture data will be averaged over the response time setting before being sent via the analog output 4 2 3 Updating the Firmware A Do not update the firmware if the versions are the same A firmware update should only be necessary if there has been a new release that specifically fixes a problem that you are experiencing with the controller 15 Connect the SCG 1 to the computer and launch LM Programmer Once connected LM Programmer will display the current version of the firmware that is installed in the SCG 1 Do not update the firmware if the versions are the same On the Info tab of LM Programmer you will see a button labeled Update Firmware click this button Select the firmware file with the did extension If there have been revisions to the firmware you will find them available for download from the Support section of the Innovate Motorsports web site The software will now prompt you to confirm that you wish to overwrite the firmware currently on your SCG 1 Click OK the gauge of the SCG 1 will go blank DO NOT power off or disconnect the SCG 1 from the computer until the fi
9. he exhaust the oxygen sensor must be connected to a powered functional SCG 1 no error codes whenever the engine is running An un powered sensor will be damaged in a short period of time when exposed to exhaust gas Do not pre warm the sensor before starting the engine start the engine as you normal would Allowing the sensor to pre warm before starting the engine will increase the possibility of damaging the sensor from shock cooling The maximum temperature of the sensor at the bung the sensor mounting location should not exceed 500 C or 900 F If these temperatures are exceeded in your application you should install the Innovate Motorsports HBX 1 heat sink bung extender p n 3729 2 5 2 Sensor Calibration Once the unit has been wired and a suitable location has been found for both the gauge and the sensor it is time to perform the sensor calibration Innovate Motorsports Direct Digital wideband measurement principal allows you to calibrate the sensor to compensate for sensor wear This procedure takes just a few moments and it will ensure the most accurate readings throughout the oxygen sensor s life This procedure is required anytime a NEW oxygen sensor is installed The calibration procedure requires that the oxygen sensor be in free air this means removed from the exhaust system completely 1 With the sensor disconnected apply power to the SCG 1 Confirm that the top right hand corner viewport displays
10. launched from Start gt Programs gt LogWorks3 gt LM Programmer from the Windows task bar Once you have completed your desired changes press the Program button on the lower right on the software application You will know that the SCG 1 has been programmed successfully when the Program button grays out 3 2 Display Settings Gauge Abbreviations 1 Wideband O2 Units WB O2 Units Allows the gauge to display O2 units in either AFR or Lambda Default setting is AFR MAP Units Allows the gauge to display pressure in either inHG PSI or kPa Default setting is inHG PSI Enable Wideband O2 WB O2 State Allows the wideband to be disabled or enabled NOTE If the wideband is disabled the O2 sensor should be removed from the exhaust to avoid damaging it Default setting is O2 enabled Fuel Type Change to different fuel types when SCG 1 is setup to display in AFR Default setting is Gasoline 3 3 RPM Settings Gauge Abbreviations 1 Mode RPM Mode Select how many pulses per rotation ppr based on your tach signal source When setting up Mode using the gauge interface you will also see a real time display of the RPM to ease the setup Default is 1 pulse per rotation Scale RPM Scale Select either 10230 or 20460 RPM scales Default is 10230 Shift RPM Set to desired RPM to trigger illumination of the shift light on the SCG 1 Default is 10230 RPM 3 4 Solenoid Settings Gauge Abbreviations A In a
11. lt analog output configuration is OV 7 35 AFR and 5V 22 39 AFR 5 Optionally the PURPLE wire can be connected to a tach signal to log engine RPM and to use the shift light function A tach signal can be acquired from the negative lead of a coil ECU negative lead of an injector or directly from the ignition box if running a multi spark i e MSD 6AL Note A tach signal can not be acquired from the negative lead of the coil on vehicles running CDI ignitions For these applications use the negative lead of an injector or a tach adapter if available for your model ignition 2 1 1 Single Innovate Device Relay Wiring Instructions TO VEHICLE SWITCHED 12 CIRCUIT TO INNOVATE ACC OR IGN OKAY DEVICE 12V RED WIRE INLINE FUSE HOLDER WITH 1A FUSE GROUND GROUND INLINE FUSE HOLDER WITH 5A FUSE CAR BATTERY TO INNOVATE 12VDC Bosch Tyco Relay SPDT 30A DEVICE GROUND Tyco Mfg V23234 A1001 X036 BLACK WIRE 2 2 Gauge Mounting and Routing The SCG 1 gauge fits in any standard 2 1 16 52mm gauge pod Mounting of the gauge should be done in such a manner that the cables are not being forcefully pulled and strained from the gauge itself Route the sensor and solenoid cables avoiding contact with the exhaust system and other vehicle components that could damage the cable Also avoid routing the cables near ignition components or other sources of RF radio frequency and EMI Electromagneti
12. n O2 error state all solenoid functions are automatically disabled To continue using the solenoid functions without the safety cuts the wideband function of the SCG 1 may be disabled from the setup menu Wastegate Duty WG Duty Adjusts the solenoid duty cycle in 2 increments The higher the duty cycle percentage the higher boost pressure will be achieved over the base wastegate spring pressure When wastegate duty is active the SCG 1 will display the duty cycle percentage on the upper right hand corner viewport Default setting is 4 11 12 Tuning Tip Start small and work up Do not increase Wastegate Duty if Boosv AFR cuts occur Remedy Boost AFR cuts before increasing Wastegate Duty Note Because of flow restrictions wastegate spring size and other factors not all applications will be able to achieve desired target boost pressure 2 Gain Ramps up the solenoid Duty Cycle to help with boost pressure drop at high engine speeds Gain is calculated as a percentage of what the current wastegate duty is set at Max Duty with Gain Gain Duty Duty For example if your Wastegate Duty is set at 30 and your Gain is 50 the SCG 1 will gain up to an additional 15 Max Duty with Gain 45 Gain is triggered 1 5 seconds into active boost and will ramp up until Max Duty is gained The SCG 1 will display the active duty cycle and progressive Gain on the upper right hand corner viewport when active Default setting is
13. ndition only occurs downstream as possible damaged at wide open throttle 3 Add an HBX 1 p n 3729 to sensor isolate the sensor from the 2 Sensor is damaged pipe 18 4 Replace sensor Error 9 Supply Supply voltage too low 1 Verify you have 12V at your Voltage too for sensor regulation power source and the circuit low can support a 3 amp draw A In an O2 error state all solenoid functions are automatically disabled To continue using the solenoid functions without the safety cuts the wideband function of the SCG 1 may be disabled from the setup menu 19
14. necting it to a computer with the LM Programmer software 3 1 1 1 2 3 3 1 2 Configuration using SCG 1 s interface buttons From the main screen press and HOLD the left interface button to put the gauge in setup mode Pressing either the left or right interface buttons will allow you to cycle through the 14 different setup parameters in the menu Once the desired setup parameter is displayed press and HOLD the left interface button to make a change Once the parameter s configuration has been entered it will start flashing Make changes by using the left or right interface buttons Once in setup mode pressing and HOLDING both interface buttons together will move you to the menu or main screen The gauge will revert back to the main screen if no there have been no button presses for 15 seconds Configuration using the LM Programmer software Refer to chapter 4 Logworks 3 amp LM Programmer Software Package to gain access to the software 1 10 Connect the OUT port of the SCG 1 to the provided serial programming cable Connect the other end of the serial programming cable to your computer If your computer does not have a serial port you can purchase a USB to Serial adapter from Innovate Motorsports P N 3733 or use any USB to serial adaptor that includes drivers Make sure that nothing is connected to the IN port of the SCG 1 Power up the SCG 1 Launch LM Programmer The LM Programmer application can be
15. rce in your vehicle A switched 12V source goes ON as soon as key on power is active The circuit to which you will pull power from should be able to support a 3 amp draw Make sure this connection is protected with a 5A fuse not supplied A Circuits that share power with the vehicle s stereo ignition system ECU lighting or fuel pump should not be used When in doubt create an additional circuit using an automotive relay available at any automotive parts supplier See the next section for a relay installation diagram 2 The BLACK wire should be grounded to a solid ground source The best possible ground source would be the battery ground post If other Innovate Motorsports devices are going to be daisy chained along with the SCG 1 it is recommended that all devices be connected to a single ground point ideally the battery ground post 3 Connect the WHITE wire to a headlight power wire a wire that goes hot with 12V when the headlights are on This enables the display to dim for better nighttime viewing DO NOT CONNECT THIS WIRE TO THE HEADLIGHT DIMMING WIRE Connection to this rheostat type of switch will cause the gauge to malfunction If you chose not to utilize the dimming feature connect the WHITE wire to ground 4 Optionally the YELLOW analog output can be connected to the analog input of other devices such as data loggers or ECUs If this wire is not being used isolate and tape it out of the way The defau
16. ressure where the safety cut will become active AFR Cut is the defined lean A F that will trigger the safety cut When the Boost Cut by AFR is triggered the SCG 1 will display O2 Cut on the upper right hand corner Default setting is a start pressure of 4 9 PSI and 13 AFR Tuning Tip Set the Start Pressure at the same pressure value as Spring Pressure Boost Control ON OFF When configured from the gauge this setting is accessed from the main screen Press and HOLD both the left and right interface buttons this will disable enable solenoid control If there are no other error codes on the status viewport of the screen the SCG 1 will display SC OFF In LM Programmer use the Boost Control ON checkbox to turn the solenoid control ON OFF Default setting is ON 4 Logworks 3 amp LM Programmer Software Package The SCG 1 can be connected directly to your Windows computer to log and analyze data with the Logworks software or to configure with LM Programmer The software is a free download on the Innovate Motorsports support section of the website 4 1 1 2 Download and Install the Logworks 3 Software Open your web browser and go to the following URL http www innovatemotorsports com support php The LogWorks 3 software download will be the very first thing on the page under the heading Software click the link to download the software Double click on the Logworks 3 installer previously downloaded from the s
17. rmware progress screen completely disappears Once finished you may disconnect the unit from the computer and exit out of the software 4 3 Logging data from your SCG 1 with LogWorks Logworks is an invaluable tool to help setup your SCG 1 The SCG 1 has four channels of sensor data built in for the tuning of not only your desired boost levels but also a safe operating air fuel ratio for your engine These channels are 16 Wideband O2 Units in AFR or Lambda RPM Boost Duty Wategate Duty of the SCG 1 solenoid PON Connect the OUT port of the SCG 1 to the provided serial programming cable Connect the other end of the serial programming cable to your computer If your computer does not have a serial port you can purchase a USB to Serial adapter from Innovate Motorsports P N 3733 or use any USB to serial adaptor that includes drivers Make sure that nothing is connected to the IN port of the SCG 1 Power up the SCG 1 Launch LogWorks The LogWorks application can be launched from Start gt Programs gt LogWorks3 gt Logworks3 from the Windows task bar Once LogWorks launches go to File gt Connect You will be prompted to connect to the serial COM port Select the COM port the device is connected to and then click Connect You will now see live data streaming from the SCG 1 To start recording go to File gt New Realtime Log or in the Toolbar click on the Tool Appendix A Limited Warranty LIMITED WARRANTY Inno
18. s instructed by Customer Service Innovate within a reasonable amount of time from its receipt of your product so shipped will ship to you at its option the repaired product or a new or reconditioned product of comparable or greater specified functionality All repaired or replacement products shall be warranted for the remainder of the original product warranty Disclaimer INNOVATE MAKES NO OTHER EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO YOUR INNOVATE PRODUCT OTHER THAN THE LIMITED WARRANTY SET FORTH ABOVE No Innovate dealer agent or employee is authorized to make any modification extension or addition to this warranty unless enforceable or unlawful under applicable law INNOVATE DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF 17 MERCHANTABILITY NONINFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE AND THE LIABILITY OF INNOVATE IF ANY FOR DAMAGES RELATING TO ANY ALLEGEDLY DEFECTIVE PRODUCT SHALL UNDER ANY TORT CONTRACT OR OTHER LEGAL THEORY BE LIMITED TO THE ACTUAL PRICE PAID FOR SUCH PRODUCT AND SHALL IN NO EVENT INCLUDE INCIDENTAL CONSEQUENTIAL SPECIAL OR INDIRECT DAMAGES OF ANY KIND EVEN IF INNOVATE IS AWARE OF THE POSSIBILITY OF SUCH DAMAGES Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you Appendix B SCG 1 Error Codes and Troubleshooting Tips
19. s tetra anaiai le daaa Eaa 10 3 1 Entering Setup Configuration ceccceeeeseeeeeeeeeeeeeeseaeeeeneeeeneees 10 3 1 1 Configuration using SCG 1 s interface buttons cee 10 3 1 2 Configuration using the LM Programmer software 10 3 2 Display Settings Gauge Abbreviations 0 ccccccessseeeessteeeeeees 11 3 3 RPM Settings Gauge Abbreviations 0 cccceseeceeceeeseteeeeneeeeenees 11 3 4 Solenoid Settings Gauge Abbreviations ccccceceeeeeeseeeeeees 11 4 Logworks 3 amp LM Programmer Software Package cccssteeeeenes 13 4 1 Download and Install the Logworks 3 Software csceeseeeees 13 4 2 LM Programme ccccccccceeesceceeeeeeeeeeeneeceeeeeeeaaeseeneeseeeesaeseeaaeesenees 14 4 2 1 Programming Analog Output ccccesseceeeeeceeeeeeeeeeeeeeeeees 14 4 2 2 Advanced Analog Output Programming cccccceeseeeeees 15 4 2 3 Updating the Firmware ccccscceeececeeeeeeeneeseeeeeseaeeesaeeeenees 15 4 3 Logging data from your SCG 1 with LOQSWOFKG cesseeeereees 16 Appendix A Limited Warranty ccccccccccceeeseeceeeeeceeeesaaeeeeeeeesaeeeeaaeeeeneesaas 17 Appendix B SCG 1 Error Codes and Troubleshooting Tips 200 18 1 SCG 1 The SCG 1 is a boost solenoid controller gauge with an integrated wideband AFR lambda control The SCG 1 also has advanced safety boost cuts based on AFR and or boost press
20. um bung placement will vary from application to application but using the guidelines below will ensure the longest sensor life with the most accurate readings Using a bung is the preferred method for mounting the oxygen sensor in all applications Weld the bung at least 24 inches after the turbocharger Using a clock as reference mount the bung between the 9 00 o clock and 3 00 o clock position Welding the bung in the lower section of the exhaust pipe can result in sensor damage caused by condensation making contact with the sensor s internal heating element A 1 bung provided in the kit will best protect the sensor When fully threaded the sensor s tip will sit flush with the inside of the exhaust piping this does not adversely effect the readings The bung should always be welded before the Catalytic Converter Welding the bung after the catalytic converter will skew the readings toward lean The skew in readings will vary with engine load and the efficiency of the catalytic converter Leaded fuel and two stroke applications will reduce the sensor s life There are many other factors that dictate the sensor s lifespan so it is impossible to predict total sensor longevity Exhaust leaks camshaft overlap and open shorty exhausts will cause false lean readings at light engine loads Typically once the engine is under load and the exhaust gas volume increases you will see accurate readings When installed in t
21. upport section of the Innovate Motorsports web site 13 4 The installer will start follow the prompts to install the software LogWorks 3 Installation x Welcome Welcome to the LogwWorks3 Setup program This program wil instal ai LogWorks3 on your computes It is strongly recommended that you exit all other Windows programs before running this Setup program Click cancel to exit Setup and close any programs you have running Click Nest to continue with the Setup program Warming This program is protected by copyright law and intemational treaties Unauthorized reproduction oe distribution of this program os any portion of i may resuk in severe civil and criminal penakies and will be prosecuted to the maximum extent possible under law 5 Once the software has been installed the LogWorks software LM Programmer manuals and tools can then be located by navigating through Start gt Programs gt LogWorks3 4 2 LM Programmer LM Programmer is used to configure settings on your SCG 1 1 Connect the OUT port of the SCG 1 to the provided serial programming cable Connect the other end of the serial programming cable to your computer If your computer does not have a serial port you can purchase a USB to Serial adapter from Innovate Motorsports P N 3733 or use any USB to serial adaptor that includes drivers Make sure that nothing is connected to the IN port of the SCG 1 2 Power up the SCG 1 3 Launch LM Programmer
22. ure Although it can be operated stand alone it has digital I O for integration with other Innovate Motorsports MTS compatible products and one configurable analog output for integration with ECU s and 3 party data loggers The following section will help you get familiar with the SCG 1 Secondary Channel Status or Error Primary Channel Right Interface Button Left Interface Button Shift Light 1 Channel Displays The SCG 1 has four different displays modes that can be cycled through on the main screen with the left and right interface buttons It can be configured to display A F or pressure as primary channels or both A F and pressure in both the primary and secondary channel viewports 2 Status or Error display The upper right hand viewport of the SCG 1 is reserved to display the status of the wastegate duty or any error codes that might be present 02 error codes will supersede all other statuses InanO2 error state all solenoid functions are automatically disabled 3 Interface Buttons Pressing either the left or right interface buttons will allow you to cycle through the 4 different display modes From the main screen pressing and HOLDING the left interface button will put the gauge in setup mode Once in setup mode pressing and HOLDING both interface buttons together will move you to the menu or main screen The gauge will revert back to the main screen if no there have been no button presses for
23. vate stands behind the quality of its products Innovate makes the following warranty to purchasers of its products All new Innovate products carry a one year warranty from the date of purchase If proof of purchase cannot be provided warranty will be determined by date of manufacture When Warranty Void This warranty shall terminate and Innovate shall have no obligation pursuant to it if i your Innovate product has been modified or repaired in a manner not previously authorized by Innovate in writing ii the identification markings on your Innovate product have been removed defaced or altered iii your Innovate product was subjected to accident abuse shipping damage or improper use iv your Innovate product was not used or configured as specified in the product manual or v your Innovate product was subjected to operating conditions more severe than those specified in the product manual Exclusions From This Warranty Oxygen Sensors are excluded from this warranty Repairs Under This Warranty In the unlikely event that your Innovate hardware product should prove defective during the warranty period contact Innovate Customer Support at http Awww innovatemotorsports com rma_form php for a return material authorization RMA Products returned for service must be securely packed to prevent damage and shipped charges pre paid along with proof of purchase and the return material authorization number to the Innovate repair location a