1. 14 CHAPTER 5 15 6 5 2009 Shop Nag Ru Page 2 of 16 SNR MPX 2E1 SFP 2E1 1Ethernet Fiber Optical Multiplexer CHAPTER 1 GENERAL INTRODUCTION 1 1 Product Description 2E1 1Ethernet Fiber Optical Multiplexer can multiplex to 2 E1 signals for transmission over an optical fiber resulting in reaching a longer distance without a repeaters and superior performance compared to copper media 2E1 1Ethernet Fiber Optical Multiplexer is the 2E1 point to point optical transport equipment that uses the FPGA chips and it is easy to upgrade It is single board structure and the largest transmission capacity is 2E1 The outer design use the standard 19 inches rack so the volume is little weight is light and operation is convenient and credit 2E1 1 Ethernet Fiber Optical Multiplexer uses the PDH fiber transmission technologies The 2Mbps E1 interfaces can connect with the exchanger light loop device and multi diplexer directly to the special network Complete alarm function for 2E1 Fiber Optical Multiplexer it is stable and easy to maintenance install and small in size It has one digital service telephone 1 2 Principle Chart and Description 8 2048 hhit s HDB3 output Fig1 PDH principle chart 6 5 2009 Shop Nag Ru Page 3 of 16
2. 1 220 Power 1 User s Manual ccccccceeceeeeeecceeeeeeuceueeeeenees 1 Note 6 5 2009 Fiber Optical Multiplexer is a sensitive electronic item please do handle with care when carrying or delivering and pay attention to against humidity Within the warranty period whenever there is a problem regarding the quality issue we will take the responsibility for it and repair will done by us Free of Charge After the warranty period we will charge accordingly depending on the fault or damage Whenever there is a malfunction of product try to identify the problem according to alarm and contact our technical support in time Shop Nag Ru Page 15 of 16
3. SNR MPX 2E1 SFP 2E1 1Ethernet Fiber Optical Multiplexer 2E1 1Ethernet Fiber Optical Multiplexer User s Manual SNR MPX 2E1 SFP 2E1 1Ethernet Fiber Optical Multiplexer nag To users Thank you for using our products Before using please read this Reference Manual carefully and keep properly 1 This product cannot be caught in or be affected with damp for they can make the performance degressive and even broken 2 Before fixing this product please check the model and according to the User s Reference Manual 6 5 2009 Shop Nag Ru Page 1 of 16 SNR MPX 2E1 SFP 2E1 1Ethernet Fiber Optical Multiplexer Contents CHAPTER 1 GENERAL INTRODUCTION 2 nnn n aun hh 3 1 1 PRODUCT DESCRIPTION 2 0cccecceeececceeceeececceecseeceecaeceecaeececcueeaeeceeeseeens 3 1 2 PRINCIPLE CHART AND DESCRIPTION 22 c2ccecccecceccecececceccaucceceeseaeecesens 3 12 4 1 3 4 CHAPTER 2 FUNCTIONS 5 2 1 FRONT PANEL 0 00 ccccecccecceccceececceecceccueeceeuecaeeceeceueeaeeceeceeaeeeeeeaeeseeeaes 5 22 PERDU MURS MEME E EE RR 5 2 1 2 Buttons in front pariel i du d vu inu gusdua nun Rua evan 6 2 1 3 Hot line phone optional
4. 6 2 1 4 Front panel DIP deliniliQn uiuere bate bane 7 2 2 REAR PANEL 22 0ccceccecececceccceececceeccecceeaeeceeceeecuecuecaueceecaeeneeeeeeaeeseeeaes 8 2 9 2 2 2 Ethernet optional component cessisse 9 2 2 3 Fiber interface sss esee nennen ines nien irs sss n nissan 10 2 2 4 E1 interface 750 2 10 CHAPTER 3 PARAMETERS AND nnn nnn 11 3 1 PARAMETERS 02 0ccccccecccecceeececceecaeececeaeececcecaeeceecaeeseecueeaeeceestesseeeaees 11 3 1 1 Fiber interface sss nins nnns 11 L 2 ET Inlerface us p A E Me eau 11 3 1 3 10 100Base T POL tr 11 3 2 DIMENSION 2 c0ccceccecceecceeceeccecceecaeececeaecuecaeeceeceuecaeeseecueeaeeceeceeeneeeaees 11 3 3 POWER SUPPLY 0 ccccecccecceeececceeaeececeeeeceececaueceecaesseeceeeaeeceesaeeneeeaees 11 3 4 OPERATION CONDITION 2 c0ccccccecceecceceecececceccaeececcaeeuscaeeseeeceeeeteneeeaees 12 CHAPTER 4 OPERATION UG RR RR RUN AD Rr ER RR RR 13 4 1 EQUIPMENT INSTALLATION 13 4 2 QUICK INSTALLATION 00cccceccccceccccceccececeeceeceeceuceecsucecseceeeueeeesauceeeaeces 13 4 3 CAUTIONS ABOUT INSTALLATION
5. 8 No 3 8 ports are ineffective 6 5 2009 Shop Nag Ru Page 8 of 16 SNR MPX 2E1 SFP nag 2E1 1Ethernet Fiber Optical Multiplexer 2 2 1 Power Supply Support AC220V and DC 48V e AC220V 180 260VAC directly insert power wire 48VDC the positive and negative of DC 48V can be optional because there is the self test circuit for the polarity inside the device 2 2 2 Ethernet optional component This model can offer 1 4 channels for 10 100M full duplex auto negotiation LAN interface support VLAN protocol this interface can continuous learn MAC addresses in the LAN that connected with it and send the address as frame in another LAN Transparence to TCP IP protocol offers security connection between different equipments in the network used widely in network connection and monitor between WAN and LAN e 10 100 Base T Ethernet port parameter e Rate 10M or 100M full semi duplex self adaption e Ethernet rate in optical line 100Mbps e Protocol support IEEE 802 3 IEEE 802 1Q VLAN e MAC address table can learn 4096 MAC address e Ethernet buffer memory 64 Mbits SDRAM e Physical interface RJ45 slot support AUTO MDIX Ethernet operating diagrammatic FIBER MUX 6 5 2009 Shop Nag Ru Page 9 of 16 SNR MPX 2E1 SFP 2E1 1Ethernet Fiber Optical Multiplexer Ethernet RJ45 ports connection NET CARD SWITCH HUB RJ45 L JEL 12345678 12345678 36145278 TX HEEL HEEL RX 12345678 12
6. SNR MPX 2E1 SFP nag 2E1 1Ethernet Fiber Optical Multiplexer 1 2 1 Description Device adopts veneer structure and can be distinguished according to the functions into 5 parts A second 2048kbi 1 3 Ch 6 5 2009 2 8 combine unit B encode decode unit C hot line unit D monitoring system E power A B and E are the basic parts achieving reverse conversion from 4 t s signals to laser signal C and D are of assistant aracters Base on IC of independence intellectual property rights Adopt veneer structure Offer 1 8 x 2Mb s digital interfaces Up to 8 E1 links on one fiber One link to service telephone for duty contract Provides 1 channel of 10M 100M support VLAN setting One channel OA for optional When fiber signal is loss users can distinguish whether the remote device is power off or the fiber line is down from the indicator status on the local device 180 260VAC amp 48VDC power options and the positive and negative of DC 48V can be optional because there is the self test circuit for the polarity inside th1e device Standard 19 inches rack little volume light weight steady capacity and convenient setup Shop Nag Ru Page 4 of 16 SNR MPX 2E1 SFP nag 2E1 1Ethernet Fiber Optical Multiplexer CHAPTER 2 FUNCTIONS 2 1 Front Panel P 3 5 HONE 12345678 on Eor L Fig2 Sketch map of the front panel 2 1 1 LED Name Color Status
7. 1 SFP 2E1 1Ethernet Fiber Optical Multiplexer nag 2 1 4 Front panel DIP definition On the front panel of standalone card in rack the SW5 DIP definition shows as follows When MSK button pushes up RLOOP1 8 1 8 E1 remote loop If the RLOOP1 is ON this means that at the far end it is doing a E1 loop back 0 means ON 1 means OFF The Remote x Loop MSK button oth its Table 1 When MSK button push down Bit1 5 mask1 5 mean 1 8E1 warning shielding 1 means OFF 0 means ON push down 0 1 0 0 1 push down 0 1 0 1 0 6 5 2009 Page 7 of 16 SNR MPX 2E1 SFP 6 8 push down 0 1 0 1 1 5 8 push down 0 1 1 0 0 4 8 push down 0 1 1 0 1 3 8 push down 0 1 1 1 0 2 8 push down 0 1 1 1 1 1 8 push down 1 0 0 0 0 E1 not shielding push down Other units Bit 6 reserved Bit 7 ON fiber interface local loop OFF Cancel the loop Bit 8 ON The Ethernet interfaces are logically separated OFF The Ethernet interfaces are exchangeable 2 2 Rear panel PWR AC220V PWR AC220V FG 48VGND LINKSPDUNKSPDUNKSPDUNKSPD Fiber 2 3 4 5 FG 48VGNp LNKSPDUNKSPDUNKSPDUNKSPD mo 2 3 4 5 7 MUN S 5 5 9 Cm Sketch map of rear panel for 750 T LI Sketch map of rear panel for 1200 Note If the function is defined as 4E1 2E1 then No 5
8. 345678 MDI MDIX Fiber MUX RJ45 There are 2 light upon per RJ45 LNK on means that LAN Link and Active SPD on means that ETH of 100M SPD off means that ETH of 10M 2 2 3 Fiber interface There is SFP slot on the rear panel supporting standard SFP module 2 2 4 E1 interface 75O BNC or 1200 RJ45 750 RXD means 750 BNC unbalance E1 input namely E1 2M TXD RXD signal input TXD means 750 BNC unbalance E1 output namely E1 2M signal output 1200 8 E1interface adopt RJ45 support 1200 balance connection E1 description output E1 output 1 8 input 6 5 2009 Shop Nag Ru Page 10 of 16 SNR MPX 2E1 SFP nag 2E1 1Ethernet Fiber Optical Multiplexer CHAPTER 3 PARAMETERS AND INDEX 3 1 Parameters 3 1 1 Fiber interface Optical interface SFP lot insert SFP module 3 1 2 E1 interface Interface code HDB3 code Line speed 2 048Mbp s 50ppm Interface standard ITU T G 703 Interface impedance 75O unbalanced BNC 120Q balanced RJ45 Allowed attenuation 0 6dBm 3 1 3 10 100Base T Port Rate 10 100M full duplex auto negotiation Protocol Support IEEE 802 3 IEEE 802 1Q VLAN MACAddress Entiries 4096Entiries Connector RJ45 3 2 Dimension 485 mm L x140 mm W x 44 mm 3 3 Power supply AC220V input voltage AC 180V 260V DC 48V input voltage 36V 72V 6 5 2009 Shop Nag Ru Page 11 of 16 SNR MPX 2
9. Describe LOS Red Active E1 signal loss Red Active Optical Signal lost OLOS 2time sec the remote device is Red Flick power off OLOF Red Active Optical SYNC loss LE Red Active Total alert when any alert in local E3 Red Active Optical BER210 F2 Green PWR Green Active Power on LINK Green Active LAN Link and Active SPD Green Active On 100M OFF 10M Note If the function is defined as 4E1 2E1 then LOS5 8 LOS3 8 is ineffective 6 5 2009 Shop Nag Ru Page 5 of 16 SNR MPX 2E1 SFP 2E1 1Ethernet Fiber Optical Multiplexer 2 1 2 Buttons in front panel PUSH OFF ON MSK DIP1 5 be used E1 warning shield DIP1 5 be used E1 remote loop MUTE standalone warning voice is on standalone warning voice is off LRS LED means Local LED means Remote PH Hot line phone not used Use Hot line phone 2 1 3 Hot line phone optional port Hot line phone not occupy 2Mbps channel transmission On the front panel there is a PH button press on the PH button on the remote site it will sound To answer it the remote site just need to press the PH button on the remote unit the alarm will cut off and just plug in the phone both side able to do the communication Setting of the manage phone e t does not occupy the 2M circuits PHONE pin definition description 1 2 SPEAKER 3 SPEAKER 4 6 5 2009 Shop Nag Ru Page 6 of 16 SNR MPX 2E
10. E1 SFP nag 2E1 1Ethernet Fiber Optical Multiplexer 3 4 Operation Condition Voltage AC180V 260V DC 48V DC 24V Consumption lt 5W Operating temperature 0C 50C Storing temperature 40C 70C Relative humidity 95 Without disturbance of erosive and solvent gas raising dust or strong magnetic field 6 5 2009 Shop Nag Ru Page 12 of 16 SNR MPX 2E1 SFP 2E1 1Ethernet Fiber Optical Multiplexer CHAPTER 4 OPERATION 4 1 Equipment installation After unpacking and before installation make sure checking the following Make sure the package is well If the package is damaged contact service office quickly for solution Check the package according to the product list if find equipment severe damaged or lack of some components please contact installation worker or service office of us Check whether the equipment type meets with the type you ordered Check whether the component is in integrity Check the power supply type 4 2 Quick installation 6 5 2009 Fasten the Equipment in 19 inch rack with the screws in the equipment package Use reliable ground connection at GND point of the equipment Use power tab to connect power according to the manual don t exchange the polarities Create user equipment connecting wire according to your demand 2M V 35 and 10 Base T then connected don t exchange receive and transfer wires Connect SFP module to the SFP lot make sure the optical fiber head
11. is clean and connection well fiber bending radius250 mm Use multimeter to test power polarity and voltage make sure it matches with equipment requirement After complete installation and make sure it s ok power on the switch Check indicator light meet with practice situation see related part of manual Shop Nag Ru Page 13 of 16 SNR MPX 2E1 SFP nag 2E1 1Ethernet Fiber Optical Multiplexer A clean steady environment and firm installation should be provided for desktop or wall hanging equipment 4 3 Cautions about installation 6 5 2009 Avoid severe liberation and mechanical damage during the process of delivering and installation Arrange fiber appropriately fiber bending radius250 mm Check voltage and polarity meet with back panel or it will cause permanent damage to the equipment The installation location should be convenient for personal passing and equipment movement The environment should be dry clean and ventilated well Essential static protective is needed during the installation and maintenance ground the chassis to increase anti interference capability and prevent lightning strike Before use the equipment independence work ground and protect ground should provided make sure it ground well Shop Nag Ru Page 14 of 16 SNR MPX 2E1 SFP nag 2E1 1Ethernet Fiber Optical Multiplexer CHAPTER 5 PACKAGE Contents in each box Fiber Optical Multiplexer
Download Pdf Manuals
Related Search
Related Contents
Pioneer SC-1525-K User's Manual Configurações da rede sem fio Operating Manual USER MANUAL LK300 Audiovox ALARM CLOCK AM/FM WITH CD PLAYER User's Manual 工事成績採点の考査項目別運用表 Copyright © All rights reserved.
Failed to retrieve file