1. Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 25 Change Alarm Time When AUX Input 1 Detected 12 26 Change Alarm Time When AUX Input 2 Detected 12 27 Change Alarm Time When AUX Input 3 Detected Refer to Table 1 for OM tt 00 99 sec oog omen EEE OE ECEE Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 28 Change Alarm Time When Magnet Detected Refer to Table 1 for OM tt 00 99 sec Omm e O O Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 29 Register 2 Digit Duress Alarm Password PW 00 99 Default PW 00 Do not use 7 7 Em m S Configuration Card Command Password Configuration PIN Note The default Password is 00 16 Star 100W IDTECK gt pass P100W 12 30 Change Alarm Time When Duress Alarm Detected za tt 00 99 sec Default TTL time 03 sec A Goes Des Command TTL time Configuration Card Configuration PIN 12 31 Test Door Open Time Set By Command 21 12 32 Test Alarm Time Set By Command 22 12 33 Test Alarm Time Set By Command 23 12 34 Test Alarm Time Set By Command 24 12 35 Test Alarm Time Set By Command 25 12 36 Test Alarm Time Set By Command 26 12 37 Test Alarm Time Set By Command 27 Outputs set by command will be teste
2. responsible for compliance could void the user s authority to operate the equipment NOTE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interface and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the radio or television off and on the user is encouraged to try to correct interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on another circuit 4 Consult the dealer or an experienced radio TV technician for help 22 Star 100W IDTECX gt ass P100W 15 Troubleshooting If a problem occurs during the use of this product do not attempt to disassemble the product
3. 4ea 4ea 4ea 7 Installation 7 1 Tear off Page 31 and use the provided template to drill two 6 32 holes and one 1 2 hole on the proper location of the wall to mount the Wall Mount bracket as shown below If the gang box is already installed on the wall then skip this step IDTECK 1 52 38 5mm ED 1 52 38 5mm Star 100W iPass P100W 3 03 77mm 7 2 Using 2 screws installthe wall mount to the wall Xx CAUTIONS w amn 5 a ra r on al a wi m vi m Z Aj ui r i a in Me T m D Before mounting the STAR 100W unit to the Wall Mount bracket operational testing of the unit should be completed as the locking pins will lock the unit to the Wall Mount Removing the unit from the Wall Mount bracket after they have been installed together may cause damages to the bracket and render its effectiveness 7 3 Insert 5 O rings to the wall mount as indicated then route the cable of the main unit through the center hole and push the main unit to wall mount to lock the main unit and make sure that the main unit is locked with the wall mount 8 Wiring Color Table SIGNAL COLOR Main Power 12V Red Power Ground GND Black Door Relay Out COM Gray with Red stripe Door Relay Out NC Blue with White stripe Door Relay Out NO White with Red stripe Alarm Relay Out COM White Alarm Relay Out NC Purple with White stripe Alarm Relay Out NO
4. Please check the following suggestions before reporting to the customer service center Operation e Problem When power is applied for the first time 3 LEDs of 100W blink and RF cards won t be recognized e Cause gt Configuration Card or Configuration PIN is not registered yet Initialized status gt The unit is malfunctioning or its data is damaged or lost due to external noise disturbance or a short circuit gt The internal circuit may be damaged or malfunctioning e Solution gt Make sure that initial setup is properly done and check the operation status f you have just installed the 100W or initialized it then the 100R is in the initialized status You need to select an operation mode and register a Configuration Card or Configuration PIN and User Access Cards For more details see 10 Initial Setup on Page 10 f a problem occurs while 100W is in the normal operation mode It is caused by system malfunctions Try turning the power of 100W off and on e f the problem still persists initialize the product See 13 Initialization for more information about how to initialize your 100W e Problem The 100W returns to the Normal Operation Mode while you are registering User Access Cards or changing settings in the Configuration Mode e Cause gt Time out Error e Solution gt If no key is pressed within 20 seconds in the Configuration Mode 100W automatically goes back to the Normal Operation Mode Registration o
5. 12 51 Disable Melody Sound Configuration PIN 12 52 Enable Melody Sound A EnaA Default setting Enable 12 60 Change Keypad Lock out Time When Try Out Error Detected mm 00 99 min Default Keypad Lock out time 01 min 6 0 ENT m m ENT Configuration Card Command Keypad Lock out time Configuration PIN 12 61 Set AUX Input 1 Detection from L to H AUX 1 input is detected on the rising edge of AUX 1 input Configuration Card Configuration PIN 6 1 Jenn 12 62 Set AUX Input 1 Detection from H to L AUX 1 input is detected on the falling edge of AUX 1 input Default setting Configuration Card Configuration PIN 6 2 Jess 18 Star 100W IDTECK PASS P100W 63 Set 2 Input Detection from L to AUX 2 input is detected on the rising edge of AUX 2 input Configuration Card Configuration PIN 6 J 3 Jen 12 64 Set AUX 2 Input Detection from H to L AUX 2 input is detected on the falling edge of AUX 2 input Default setting Configuration Card Configuration PIN 6 4 Jen 12 65 Set AUX 3 Input Detection from L to H AUX 3 input is detected on the rising edge of AUX 3 input Configuration Card Configuration PIN 6 s en 12 66 Set AUX 3 Input Detection from H to L AUX 3 input is detected on the falling edge of AUX 3 input Default setting Configuration Card Configuration PIN 6 J 6 JEn 12 67 Set Exit Button Input De
6. Re Initialize and Erase All Setup Data Use this command when you really want to erase all data and start the unit from the beginning Configuration Card a Configuration PIN goog 13 Initialization When you lost the Configuration Card or forgot the Configuration PIN number you may need to re initialize the unit for new setup There is a hard wired Initialize function on the unit x WARNING You may lose all setup data after Initialization 13 1 Hardware Initialization When the Configuration Card or PIN is lost 1 Open the top case by screwing the four bolts out from the back 2 As shown in the left picture short the two pins of the jumper while power is applied 3 The 3 color LED blinking with beep sound indicates successful initialization short 1 Power off the Main Unit 2 Connect Orange wire and Orange White banded wire together and power on the Main Unit 3 The 3 color LED blinking with beep sound indicates successful initialization GND Orange wire m Orange with White stripe DOE short 4 Power off the Main Unit again 5 Disconnect Orange wire and Orange White banded wire as shown above normal connection diagram and power on the Main Unit GND Orange wire Orange with White stripe 21 Star 100W ieass P100W 14 FCC Registration Information FCC REQUIREMENTS PART 15 Caution Any changes or modifications in construction of this device which are not expressly approved by the
7. Warranty Policy and Limitatin of Liability IDTECK warrants this product against defects in material and workmanship for the period specified below from the date of purchase under normal customer use This Warranty doesn t apply 1 to any product which has been dismantled without authorization of IDTECK or and has a damaged or detached QC label on its back side 2 to any losses defects or damages caused by improper testing operation installation maintenance modification alteration or adjustment 3 to any product with a damaged or faded serial number on it or 4 to any losses defects or damages caused by lightning or other electrical discharge natural disaster misuse accident or neglect This Limited Warranty is in lieu of all other warranties obligations or liabilities on the part of IDTECK and IDTECK DISCLAIMS ANY AND ALL WARRANTY WHETHER EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IDTECK does not and cannot know who is present what property is located where this product will be used it would be extremely difficult to determine the actual damages that may result from a failure of the product to perform as anticipated and the low price of this product is based upon the nature of the product provided and the limited liability that IDTECK assumes IDTECK IS NOT RESPONSIBLE FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR LOSS DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR OTHER LOSS AND IDTECK
8. erase all setup data 12 11 Add User Access Cards RF CARD ONLY MODE aa Configuration Card Command Cards to be registered 12 12 Add User Access Cards RF CARD PIN MODE a A af Configuration Card Command Cards to be registered 12 13 Add User Access PIN PIN ONLY MODE 4 6 digit PIN ENT 1 3 EnT 4 6 digit PIN ENT 4 6 digit PIN ENT Configuration PIN Command PINs to be registered Configuration PIN 12 14 1 Delete User Access Cards RF CARD ONLY MODE amp RF CARD PIN MODE 14E a a Tin Configuration Card Command Cards to be deleted o auras 12 14 2 Delete User Access PIN PIN ONLY MODE 4 6 digit PIN EnT 1 4 ENT 4 6 digit PIN ENT 4 6 digit PIN ENT Configuration PIN Command PINs to be deleted Configuration PIN 14 Star 100W IDTECK aPass P100W 12 15 Add User Access Card PIN RF PIN Combination Mode ao ca or OF seen Configuration Card Command PIN PIN Configuration Card lt TABLE 1 gt SETTINGS FOR COMMAND Symbol Setting Values Examples Remarks You must add value D and EX1 Activate Door Relay In Safe amp Secure Mode D Safe 8 Secure Mode 50 2 Door Relay 01 OM 51 Activate Mode Activate only in Secure Mode Activate in Safe amp Secure Mode Setting Value for activating Output Port 2 Activate Output Port Activate only Door Relay Activate only Alarm Relay Activ
9. of Door Lock to Door RELAY NO White Red banded wire Connect wire of Door Lock to Power GND wire 9 3 Alarm Device Connection Connect Alarm RELAY COM White wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a larger capacity one Connect wire of Alarm Device to Alarm RELAY NO Purple wire Connect wire of Alarm Device to Power GND wire 9 4 Exit Button Connection Connect one of the wires of Exit Button to Exit Button Input Yellow Red banded wire Connect the other wire of Exit Button to Power GND wire If a normally closed Exit button is used see section 12 67 to change the detection scheme from the default 9 5 Door Contact Sensor Connection Connect Door Contact sensor COM wire to Door Contact Input Green wire Connect Door Contact sensor NO wire to Power GND wire If a normally closed Door Contact sensor is used see section 12 69 to change the detection scheme from the default 9 6 Auxiliary Input Device Connection Applied to AUX Input 1 2 3 Connect one wire of the Auxiliary Input Device to the AUX Input wire Input 1 Orange Input 2 Green White banded Input 3 Brown wire Connect the other wire of Auxiliary Input Device to Power GND wire If a normally closed input device is used see section 12 61 63 amp 65 to change the detection schemes from the default 9 7 Auto Dialer Connection Se
10. to COM1 or COM2 Port of the PC Install and run STAR 100R PRO Application Software 9 10 Chime Bell Connection Separate purchase required Connect wire of Chime Bell unit to Bell Output Brown White wire of Main Unit Connect wire of Chime Bell unit to Power GND wire 10 Initial Setup The Flash memory of each shipped STAR 100W contains a minimum set of default values but it does not have any other preprogrammed values or user s data in it therefore Initial Setup is required upon the first time the unit is powered up in order to operate the unit properly 10 1 Registration of RF Cards for RF CARD ONLY MODE 1 Apply 12VDC to the unit All 3 LEDs will be flashing with a powered up melody do mi sol me do do mi sol do 2 Press o 1 JEn on the keypad RF CARD ONLY MODE 3 Present RF Cards in the following order to register a Configuration Card and User Access Cards Configuration Card User Access Cards Configuration Card again to end the task x NOTE The user may choose to register the 8 digit card numbers via the keypad instead of presenting the cards to the unit In this case the user must know the 8 digit representation of each card 4 The first card presented becomes the Configuration Card and the following RF Cards are registered as User Access Cards Once all User Access Cards have been registered present the Configuration Card again to complete the registration process Please keep the Config
11. Model 100W IP100W CPU Dual 8bit Microprocessor Memory Program Memory 20KByte ROM Data Memory 2KByte EEPROM User 512 Users j E T IPK50 Up to 2 inches 5 cm Read Passive Type ano IPC170 IPC180 Range Up to 4 inches 10 cm Up to 4 inches 10 cm Active Type IDA150 IDA200 Compatible N A Reading Time Card 30ms Power Current DC 12V Max 200mA External Reader Port 1 Port 26bit Wiegand Communication RS232 5 Ports Input Port Exit Button Door Contact Aux 1 Aux 2 Aux 3 2 Ports Form C Relay Output COM NO NC DC12 18V Rating Max 2A Output Port 1 Port Chime Bell Output DC5V Rating Max 500mA 1 Port TTL Output DC5V Rating Max 20mA 4 Star 100W ELA pass P100W Keypad 12 Button Numeric Membrane Keypad LED Indicator 3 Array LED Indicators Red Green and Yellow Beeper Piezo Buzzer Operating Temperature 35 to 65 C 31 to 149 F Operating Humidity 10 to 90 relative humidity non condensing Color Material Dark Pearl Gray Polycarbonate Dimension W x H x T 87mm x 100mm x 31mm 3 4 x 3 94 x 1 22 Weight 210g 0 46lbs Certification UL FCC CE MIC 5 Front Panel Description Main Unit of Star 100W iPASS 100W KEYPAD 9 cz 6 Identifying Supplied Parts Please unpack and check the contents of the package o 60 o Main Unit Wall Mount O Ring User s Manual lea lea 5ea copy nn 3 5 40 Screw 3 5 12 Screw Anchor Bolt
12. Purple Star 100W iPass P100W IDTECK TTL Out Orange with White stripe Chime Bell Out Brown with White stripe Wiegand Data 0 In Pink Wiegand Data 1 In Cyan Exit Button In Yellow with Red stripe Door Contact In Green Aux In 1 Orange Aux In 2 Green with White stripe Aux In 3 Brown RS232 TX Gray RS232 RX Blue RS232 GND Yellow Please cut out the tail connector before installation 9 System Wiring for Typical Application DOOR RELAY NO CHIME ALARM Ri COM ieee DOOR apes CONTACT PIR SENSOR Star 100W IDTECK iPass P100W 9 1 Power Connection Connect wire of DC 12V power to Red wire and Red White banded wire Connect Power GND wire of DC 12V to Black wire and Black White banded wire 9 2 Door Lock Connection 9 2 1 Connection of POWER FAIL SAFE Door Lock Connect Door RELAY NC Blue White banded wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a larger capacity one Connect wire of Door Lock to Door RELAY COM Grey Red banded wire Connect wire of Door Lock to Power GND wire 9 2 2 Connection of POWER FAIL SECURE Door Lock Connect Door RELAY COM Grey Red banded wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a larger capacity one Connect wire
13. Registration Others IDTECK RMA Center gt gt 3F 10 10 1 10 2 Dodang Dong Weonmi Gu Bucheon Si Gyeonggi Do 157 030 Korea Telephone 82 2 2659 0055 HQ 82 32 671 5642 RMA Center Fax 82 2 2659 0086 HQ 82 32 671 5641 RMA Center Website www idteck com e Training Center www idtecktraining com 30 P s 6 32 hole L2 hole Star 100W IDTECK iPass P100W The specifications contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com MAM100WHE 1X Feb 2008 Copyright 2008 IDTECK Co Ltd
14. S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT To obtain repair or replacement under the terms of this warranty visit IDTECK s Website http www idteck com and place an online RMA request After an RMA code is issued return the product along with the authorization RMA code gt gt Warranty Period Warranty Product Category Period 1 RF CARD Active type 1 year 2 RF READER FINGERPRINT READER 3 STANDALONE CONTROLLER 3 years 4 CONTROL PANEL 5 FINGERPRINT CONTROLLER 6 MOLDED RF READER RF10 RF20 RF30 RF TINY IP10 IP20 IP30 SR10E SR10UE SR10SE SR10RWE SR10BE Lifetime 7 RF CARD Passive type IDC80 IDC170 IDK50 IMC125 LXK50 IPC80 IPC170 IPK50 ISC80 ISC80S ISK50 IMC135 IHC80 IP100 IP200 29 Star 100W IDTECX gt ass P100W RMA REQUEST FORM IDTECK accepts only on line RMA requests on our Website www idteck com Please provide us with basic information in the below form so that we can understand your problems better Send us back this form with your products after an RMA code is issued on our Website This form is not compulsory RMA Authorization Code 1 Company Name 2 Model Name 3 Serial No 4 Original Invoice No 5 Distributor 6 Purchasing Date 7 RMA Request Date Please check your problems Card Reading Power Keypad Communication Relay LCD LED amp Buzzer
15. User s Manual Star 100W iPass P100W INDTECK 100W Star 100W IDTECX gt pass P100W Table of Contents 1 Important Safety Instructions s sssssssissisrnsrosrisrnnrosnnsnnnnnsnnnnnnnnnnnnnnnnnnnnnannnnnnns 3 Zi General aaaea aa ij i i DITA 3 Be Features sis is ie iai i i i i i i i i i i i 4 A SPECIFIC AMON iii iii iii i iii a a i i i i i k iii 4 5 Front Panel Descriptors 5 6 Identifying Supplied Parts ssc cesses 5 Te AMS Cell ON is i ii ii i Gi i i iii i i ii i adi i i i i i 5 8 Wiring Color Tablar 6 9 System Wiring for Typical Application sssrinin 7 LO Meal Hal SEW is iii iii id ai i ia ai i i a i i i i 9 LE O DELAEIO I iii iii iii ia i ii iii ii ii ij i ii 11 12 Setting C hahges sis sais tincssvinesuscsesasveticnnsaevsdnrevastvsanrecisiveiareiiviedieunaiiiin 12 13 Initial ZAGON iniia i i 21 14 FCC Registration Information ssssssssssssssssssssssssssssssssssesesesesesesecesecesecess 22 15 TROUDIESNOOU NG ii iaisi cakiniia sakas i ii ii vi i i i i i 23 16 Warranty Policy and Limitatin of Liability sssrin 29 174 Template sis iii is i i iii i ia ii ii i ii i i i i ij 31 Star 100W IDTECX eass P100W 1 Important Safety Instructions When using your Star 100W iPASS IP100W basic safety precautions should always be followed to reduce the risk of fire electrical shock and injury to persons 1 Read and understand all instructions Follow all warnings and instructions marked on the product Do no
16. ate only TTL Output Activate Door Relay amp TTL Activate Alarm Relay amp TTL Le tt is the activating time value seconds from 01sec to 99sec tt value 00sec means no operation Pw PW is the 2 digit Password for Duress Alarm Do not use 77 for PW as it is used for Secure Mode mm mm is the activating time value minutes from 01min to 99min mm value 00min means no operation 12 21 Change Door Open Time When User Access Card or PIN is Granted tt 00 99 sec Default Door Open time 03 sec Configuration Card Command Door open time TTL time Configuration PIN EX2 Activate Alarm Relay amp TTL only in Secure mode Secure Mode 00 AlarmRelay amp TTL 06 OM 06 12 22 Change Alarm Time When User Access Card or PIN is Denied Refer to Table 1 for OM tt 00 99 sec Default Alarm time 02 sec omen tte tte tt eng Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 15 Star 100W IDTECX i ieass P100W 12 23 Change Alarm Time When Try Out Error is Detected Refer to Table 1 for OM tt 00 99 sec Default Alarm time 10 sec ome een O em Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 24 Change Alarm Time When Door Contact Error is Detected Refer to Table 1 for OM tt 00 99 sec Door Open Time out setting is required for activating refer to 12 81 Qe Owe Me Ate Mme
17. d Configuration Card Command Configuration PIN 12 39 Change Chime Bell Activating Time tt 00 99 sec Default Chime Bell time 05 sec 3 0 Jen ENT Command Chime Bell time Configuration Card Configuration PIN 12 41 Open Door Unconditional Configuration Card Configuration PIN 4 1 En 12 42 Close Door Unconditional Configuration Card configuration PIN 4 2 Jen 12 43 Enable QUICK ACCESS MODE When QUICK ACCESS MODE is enabled Door will open simply by pressing lent Configuration Card Configuration PIN 4 3 Jen 12 44 Disable QUICK ACCESS MODE Configuration Card Configuration PIN 4 4Jes Default setting Disable 17 Star 100W IDTECX gt ass P100W 12 45 Enable Toggle Mode for Lock Control 4 If you enable the Toggle Mode the door will be toggled open closed when a A registered card or PIN is entered You may use this function for Arm Disarm for burglary alarm system Configuration Card Configuration PIN 12 46 Disable Toggle Mode for Lock Control Configuration Card Configuration PIN 4 6 12 47 Enable Lock followed by Door Contact Fo 4 If you enable Lock followed by Door Contact the door will only be locked A followed by Door Contact so the door will remain unlocked until the door is 4 completely closed Configuration Card Configuration PIN 12 48 Disable Lock followed by Door Contact Configuration Card Configuration PIN 4
18. d enter the 2 digit command code RF Only Mode or RF PIN Mode PIN Only Mode or 4 6 digit PIN ENT Configuration Card Command Code Configuration PIN Command Code 12 IDTECK Command 11 12 13 14 15 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 39 41 42 43 44 45 46 47 48 51 52 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 Star 100W iPass P100W Summary Table of Commands Action Change setting values Add User Access Cards RF CARD ONLY MODE Add User Access Cards and PIN RF CARD PIN MODE Add User Access PIN numbers PIN ONLY MODE Delete User Access Cards or PIN Add User Access Card PIN RF PIN Combination Mode Change Door open time when User Access Card or PIN is granted Change Alarm time when User Access Card or PIN is denied Change Alarm time when Try Out error detected Change Alarm time when Door Contact error detected Change Alarm time when Aux Input 1 detected Change Alarm time when Aux Input 2 detected Change Alarm time when Aux Input 3 detected Change Alarm time when magnet detected Register 2 digits Duress Alarm password Change Alarm time when Duress Alarm detected Test Door open time set by command 21 Test Alarm time set by command 22 Test Alarm time set by command 23 Test Alarm time set by command 24 Test Alarm time set by command 25 Test Alarm time set by command 26 Test Alarm time set by command 27 Change Chime Bell activatin
19. e Exit Button If the 100W responds when the exit button is pressed replace the exit button because it is faulty If the 100W does not respond the 100W is malfunctioning Initialize the product Caution Upon initialization all data default value will be restored See Installation to connect the exit button e Problem An RF card is successfully recognized by the exit reader but the data transmission to the PC fails or incorrect data is transmitted e Cause gt Incorrect connection between the exit reader and the 100W gt Communication error gt Malfunction of the exit button 26 Star 100W ES ipass IP100W gt The unit is malfunctioning or its data is damaged or lost due to external noise disturbance or a short circuit e Solution Check the connection between the exit reader and the 100W DC 12V Terminal Power Supply Cd o ollt o 100V 220V DC 12V Power Supply Connecting a External Reader Check the operation of the exit reader 1 Check the wiring between the exit reader and the 100W to see if there is a short circuit or cutoff 2 ets if any noise can be introduced into the communication wires between the exit reader and the Test the exit reader output by checking the Wiegand communication cable with a measuring instrument With a measuring instrument check if any noise is present in the communication cable If a trace of fete detected enhance the GND signal by us
20. e sure that communication settings and cable connection are correct 24 Star 100W IDTECX eass P100W Check the communication settings of the 100W and a PC 1 Make sure that the COM port number is correct in the communication settings of the application software 2 Baud rate is fixed at 9600bps Make sure that communication settings of the application software are as follows Parity bit None Data bit 8bits Stop bit 1bit Make sure that the communication cables are correctly connected 1 Check the cable connections between the 100W and the PC 2 Beware of the maximum cable length RS232 Maximum of 15m The maximum transmission distance for each communication type is greatly affected by the communication environment Eliminate any electrical noise around the communication cable or seperate it from other cables Keypad e Problem An RF card works properly but the 100W won t recognize the RF card number when it is entered on the keypad e Cause gt Improper system settings gt The unit may be malfunctioning or its data is damaged or lost due to external noise disturbance or a short circuit e Solution gt Check if the buzzer beeps when a key is pressed If the buzzer beeps 1 Present the Configuration Card or press the Configuration PIN ENT 2 Enter 73 ENT to enable Keypad Input To Enter ID Number See 12 Setting Changes for more details If the buzzer does not beep 1 If the buzz
21. er User Access PIN s one by one and then enter 4 5 digit PIN lens Configuration PIN to complete the registration 4 6 digit PIN JEN 4 6 aigit PIN Jen 4 6 digit PIN ent Configuration PIN User Access PIN Enter the Configuration PIN again to complete the registration 4 The first 4 6 digit PIN becomes the Configuration PIN and the subsequent 4 6 digit PINs are registered as User Access PINs Once all User Access PINs have been registered enter the Configuration PIN again to complete the registration Please store the Configuration PIN for future changes 5 Now the Main Unit enters the normal operation mode with default settings 10 4 Registration of RF PIN Combination MODE 1 Apply 12V DC to the unit All 3 LEDs will be flashing with a power up melody 2 Press 0 5 E from the keypad RF PIN Combination Mode 3 Present Configuration Card to register Configuration Card to the unit 4 Present RF Card s or enter 4 6 digit PIN number s to register user access card s or PIN s 5 Present Configuration Card to complete the registration process x on oo oo or or or PIN PIN PIN Configuration Card Configuration Card 10 Star 100W IDTECK iPASs P100W 10 5 Factory Default Setting Values After the Initial Setup the Main Unit uses the factory default setting values below to execute the normal operation mode You may want to change these factory setting
22. er beeps after a certain length of time passes see the following a If unregistered IDs are entered 5 times default in a row keys on the keypad do not function for 1 min default b The following is about how to configure the maximum number of trials allowed Present the Configuration Card or press the Configuration PIN ENT Press 82 ENT to set Number of Times of Try Out Press 2 digits for Try Out times ENT e g 10 ENT Allow 10 trials before a keypad freeze c See Page 23 for more information about how to set how many trials to allow before keypad freezes 2 If the buzzer never beeps when a key is pressed initialize the product See 13 Initialization for more information about how to initialize your 100W 25 Star 100W midui pass IP100W External Device e Problem The exit button won t work e Cause gt Incorrect connection between the exit button and the 100W gt Malfunction of the exit button gt Internal circuit may be damaged or malfunctioning e Solution Check the connection between the exit button and the 100W DC 12V Power Supply ma 2 100V 220V Yellow Red Stripe Connecting an Exit Button Caution Make sure to use an NO Normally Open type exit button Check the operation of the Exit Button 1 Check the wiring between the Exit Button and the 100W to see if there is any short circuit or cutoff 2 Try connecting the two wires connected to th
23. figurable I O interfaced behaviors many of the Star 100W iPASS IP100W internal behaviors are programmable as well The internal operating parameters include the number of incorrect access attempts before an alarm is triggered tampering protection from mounting removal and timers Furthermore every event or transaction can be captured and time stamped by the Star LOOW iPASS IP100W application software via the provided RS 232 wires IDTECK Star 100W irass P100W 3 Features 125KHz Standalone Proximity PIN Single Door Access Controller 100W PSK modulation IP100W ASK EM Format Basic Time amp Attendance Function 512 Users 1 External Reader Port for Exit 26bit Wiegand Standalone Network Communication via RS232 AIl I Os and Operation Time Programmable by Keypad 5 Independent Inputs and 4 Outputs Including 2 Form C Relay Outputs Keypad Lock by Try out Error Alarm Function Duress Mode Function Toggle Mode for Door Opening Closing Lock Control by Door Contact Switch Safe Default Secure Mode Available Dual Tamper Switches Chime Bell Output Mode Selection RF Only PIN 4 6 digits Only RF P W 4 digits RF or PIN Options 4ch Voice Auto dialer Compatible Software STAR 100R PRO Weather proofed Comparison Table 100W 125KHz PSK modulation IP100W 125KHz ASK EM Format 4 Specification
24. g time Open door unconditionally Close door unconditionally Enable QUICK ACCESS MODE Disable QUICK ACCESS MODE Enable Toggle Mode for Lock control Disable Toggle Mode for Lock control Enable Unlock followed by Door Contact Disable Unlock followed by Door Contact Disable Melody sound turning off both the melody amp keypress audio feedback Enable Melody sound Change keypad lock out time when Try Out error detected Set Aux Input 1 Detection from L to H Set Aux Input 1 Detection from H to L Set Aux Input 2 Detection from L to H Set Aux Input 2 Detection from H to L Set Aux Input 3 Detection from L to H Set Aux Input 3 Detection from H to L Set Exit Button Input Detection from L to H Set Exit Button Input Detection from H to L Set Door Contact sensor Input Detection from L to H Set Door Contact sensor Input Detection from H to L Activate TTL output to H Activate TTL output to L Enable Keypad Input To Enter ID Number Disable Keypad Input To Enter ID Number 13 Star 100W oe ipass IP100W 77 Enable Chime Bell Output 78 Disable Chime Bell Output 80 Set delay time to activate SECURE MODE 81 Set Door Open time out for Door Contact sensor 82 Set number of times of Try Out 83 Set input key press time out time 84 Set Tamper Alarm output port 88 Enable Tamper Alarm 89 Disable Tamper Alarm 99 Re Initialize and
25. hat needs to be deleted a Present the Configuration Card or press the Configuration PIN ENT b Press 73 ENT to enable Keypad Input To Enter ID Number c Present the Configuration Card or press the Configuration PIN ENT d Press 4 ENT to delete the User Access Card s e Press PIN ENT Repeat this process if there re more than one card to delete f Present the Configuration Card or press the Configuration PIN ENT Q See 12 Setting Changes for more information Lost the Configuration Card 1 If the Configuration Card is missing you cannot perform registration deletion setting adjustment 2 Initialize the product See 13 Initialization for more information about how to initialize your 100W System Initialization e Problem The Configuration Card is lost and can t register delete User Access Cards PINs or change settings e Cause gt Missing Configuration Card e Solution gt Without the Configuration Card you have no choice but to initialize your 100W if you wish to change settings See 13 Initialization for more information about how to initialize your 100W Communication e Problem 100W is connected to a PC but communication won t be established e Cause gt Improper communication settings gt Incorrect communication cable connection b The unit is malfunctioning or its data is damaged or lost due to external noise disturbance or a short circuit e Solution gt Mak
26. hime Bell Output Configuration Card Configuration PIN Default setting E nable 12 78 Disable Chime Bell Output Configuration Card Configuration PIN ENT 12 80 Set Delay Time to Activate SECURE MODE mm 00 99 min Default Delay time 00 min oey aed Configuration Card Command Delay time Configuration PIN 12 81 Set Door Open Time out for Door Contact Sensor tt 00 99 sec Default value 00 sec means no detect Door Contact Sensor refer to 9 12 24 for Alarm time settings E awe Configuration Card Command Door Open time out Configuration PIN 12 82 Set Number of Times of Try Out NN 00 99 times Default Try out numbers 05 times 0035 e Star Ok Master Card gt Configuration Card Command Try out numbers Configuration PIN 12 83 Set Input Keypress Time out Time tt 10 99 sec Default Keypress time out 20 sec Minimum tt 10 sec Configuration Card Command Keypress time out time Configuration PIN 12 84 Set Tamper Alarm Output Port Refer to Table 1 for OM Default Output port 02 Alarm Relay sa em oee Configuration Card Command Alarm Output Port Configuration PIN 20 Star 100W 12 88 Enable Tamper Alarm To comply with UL 294 the Standard for Access Control System Units Tamper Alarm must be enabled Configuration Card Fa Configuration PIN 12 89 Disable Tamper Alarm Configuration Card Configuration PIN s 9 Jens Default setting 12 99
27. iPass P100W 11 3 Exit Open the Door To request an exit from the inside an Exit Button can be used to open the door for the same duration as in 11 2 Exit TA TA 11 4 Action and Alarm Caused by Unregistered Card or PIN When an unregistered Card or PIN is read access is denied and the Alarm can be activated for 2 seconds along with sol do sol do melody O02 S Unregistered Card or PIN If you do not want to activate the Alarm in case of unregistered access attempt then you can change this setting as shown in section 12 11 5 Secure Mode The last person to exit can change the operation of the unit from Normal Mode to Secure Mode by entering the Secure Code of on the keypad gt Change to Secure Mode The Secure Mode will revert back to the normal mode when a registered card or PIN is presented entered 11 6 DURESS Alarm In case of Duress enter the 2 digit Duress Password 862 and the door will open as usual however the Duress Alarm TTL Output will activate an external Auto Dialer to notify the appropriate personnel See section 9 7 and 12 29 for more instructions on this feature 11 7 Chime Bell Operation The key can be used to activate an external Chime Bell for 5 seconds the default value 12 Setting Changes Configuration Card PIN is required to change the existing or default setting values or to manage user s access First present the Configuration Card or enter the Configuration PIN an
28. ing the shield wire and a spare wire of the cable as It is recommendable to stabilize communication signals by using a repeater e See 7 Installation to find out more about wiring e Problem A door lock won t work e Cause gt An error in connection between the door lock and the 100W gt A door lock error Sii na The unit is malfunctioning or its data is damaged or lost due to external noise disturbance or a short circuit e Solution gt Check the connection between the door lock and the 100W The connection method differs depending on the door lock type and its operation type Normally Open Normally Close 27 Star 100W IDTECX iPass P100W 100V 220V im o s 0 Uait m 3 co 100V 220V F DC 12V Power Supply Connecting a Door Lock Power Fail Safe Mode IDTECK 100w 100V 220V ei Dace Bh 3E Red Ao Gere Fits DC 12 Power V Supply 100V 220V Connecting a Door Lock Power Fail Secure Mode Power Supply gt Check the door lock operation and the connection between the door lock and the 100W 1 Check the wiring between the door lock and the 100W to see if there is any short circuit or cutoff 2 Check the operation of the door lock Remove the door lock from the 100W and check the relay output from the 100W with a measuring instrument If the relay output from the 100W is normal replace the door lock 28 Star 100W IDTECX gt ass P100W 16
29. parate purchase required The Auto dialer function of this unit has not been evaluated by UL Connect the input wire of Auto Dialer to TTL output Orange White banded wire Connect wire of Auto Dialer to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a larger capacity one Connect wire of Auto Dialer to Power GND wire Connect Telephone Line plug RJ 14 to Auto Dialer If an active High Auto Dialer is used see section 12 71 to change the TTL output level from the default 8 Star 100W IDTECX gt ass P100W 9 8 Wiegand Input Connection from another Compatible Wiegand Reader Separate Purchase Connect wire of Reader to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Reader to Power GND wire Connect Wiegand output DATAO wire of the additional Reader to DATAO Pink wire Connect Wiegand output DATA1 wire of the additional Reader to DATA1 Cyan wire 9 9 RS 232 Communication Port Connection A 9 pin connector COM Port female is required for RS 232 communication between the 100W and a PC Connect RS 232 TX Grey wire of Main Unit to pin number 2 of 9 pin connector Connect RS 232 RX Blue wire of Main Unit to pin number 3 of 9 pin connector Connect RS 232 GND Yellow wire of Main Unit to pin number 5 of 9 pin connector Plug in 9 pin connector
30. r Deletion e Problem User Access Card or User Access PIN won t be registered any more e Cause gt Improper use or settings b The maximum number of users that can be registered 512 is already reached e Solution gt Make sure that installation and operation are properly done f you have just installed the 100W or initialized it then the 100R is in the initialized status which means you need to choose an operation mode and register a Configuration Card or Configuration PIN and User Access Cards For more details see 10 Initial Setup on Page 10 f you d like to add more User Access Cards or PINs see Page 16 23 Star 100W simsus pass IP100W e Problem User Access Cards or User Access PINs won t be deleted e Cause gt Improper use or settings gt The unit is malfunctioning or its data is damaged or lost due to external noise disturbance or a short circuit e Solution gt Make sure that installation and operation are properly done The 100W is in the Normal Operation Mode Have the Configuration Card 1 Have the User Access Card s that needs to be deleted a Present the Configuration Card or press the Configuration PIN ENT b Press 14 ENT to delete User Access Cards c Present the User Access Card s that you wish to delete Repeat this process if you have more than one card to delete d Present the Configuration Card or press the Configuration PIN ENT 2 Lost the User Access Card s t
31. rols that are not covered by this manual may damage the unit and will often require extensive work by a qualified technician to restore normal operation d If the product exhibits a distinct change in performance AUN N 2 General The Star 100W iPASS IP100W is an intelligent PIN amp Proximity Single Door Controller that combines the convenience of wireless entry with the security of an alarm system Also the Star 100W iPASS IP100W system will give you field proven reliability and a cost effective solution anywhere access controls and high security are required Each standard unit can store up to 512 users The task of assigning cards and managing a user s database is so simple user friendly and can be accomplished in many ways it could be as simple as presenting each card to the unit or as descriptive as a user s database with an easy to use Graphical User Interface The Star 100W iPASS IP100W can interface and operate with these accessories Exit Request button Door Contact sensor PIR sensor Fire sensor and other sensors via 5 independent input ports Also output ports which include 2 Relays and 2 TTL outputs can be used to control the operation of other accessories such as Electric Magnetic Door Lock Alarm Chime Bell and Auto Dialer Moreover the status or behaviors of these input and output accessories are configurable to provide the system administrator with complete customized control of the system Besides the above con
32. t use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning If necessary use mild soap Do not use this product near water such as bath tub wash bowl kitchen sink laundry tub in a wet basement or swimming pool 5 This product should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied to your installation site consult your dealer or local power company 6 Never push objects of any kind into this product or through the cabinet slots as they may touch voltage points or short out parts that could result in fire or electric shock Never spill liquid of any kind on the product To reduce the risk of electric shock do not disassemble this product by yourself but take it to qualified service whenever service or repair is required Opening or removing the covers may expose you to dangerous voltages or other risks Also incorrect reassembly can cause electric shock when the unit is subsequently used 8 Unplug this product from the Direct Current DC power source and refer to qualified service personnel under these conditions a When the power supply cord or plug is damaged or frayed b If liquid has been spilled on the product c lf the product does not operate normally after following the operating instructions in this manual Adjust only those controls that are covered by the operating instructions in this manual Improper adjustment of other cont
33. tection from L to H Exit Button input is detected on the rising edge of Exit Button input Configuration Card Configuration PIN 6 7 Jen 12 68 Set Exit Button Input Detection from H to L Exit Button input is detected on the falling edge of Exit Button input Default setting Configuration Card Configuration PIN 6 8 Jenn 12 69 Set Door Contact Sensor Input Detection from L to H Door Contact input is detected on the rising edge of Door Contact input Configuration Card Configuration PIN 6 9 ENT 12 70 Set Door Contact Sensor Input Detection from H to L Door Contact input is detected on the falling edge of Door Contact input Default setting Configuration Card Configuration PIN 70 ENT 12 71 Activate TTL Output to H TTL output changes the state from logic 0 to logic 1 when it activates Configuration Card Configuration PIN ENT 12 72 Activate TTL Output to L TTL output changes the state from logic 1 to logic 0 when it activates Default setting Configuration Card Configuration PIN ER 12 73 Enable Keypad Input To Enter ID Number Keypad input is enabled to enter the ID numbers through keypads Configuration Card Configuration PIN 12 74 Disable Keypad Input To Enter ID Number Keypad input is disabled to enter the ID numbers through keypads Default setting Configuration Card Configuration PIN ye 19 Star 100W 12 77 Enable C
34. uration Card in a secure location for future changes 5 Now the Main Unit enters the normal operation mode with factory default settings 10 2 Registration of RF Cards with PINs for RF CARD PIN MODE 1 Apply 12VDC to the unit All 3 LEDs will be flashing with a powered up melody do mi sol me do do mi sol do 9 Star 100W ieass P100W 2 Press o 2 Jenn on the keypad RF CARD PIN MODE 3 Present RF Cards in the following order to register Configuration Card and User Access Cards 4 6 digit Personal Identification Number PIN for each User Access Card Star VR A 4 6 digit PIN ENT s 9 Configuration Card User Access Cards PINs Configuration Card again to end the task 4 The first card presented becomes the Configuration Card and the following RF Cards PINs are registered as User Access Cards with assigned PINs Once all User Access Cards and PINs have been registered present the Configuration Card again to complete the registration process Please keep the Configuration Card in a secure location for future changes 5 Now the Main Unit enters the normal operation mode with default settings 10 3 Registration of PIN ONLY MODE 1 Apply 12VDC to the unit All 3 LEDs will be flashing with a powered up melody do mi sol me do do mi sol do 2 Press o 3 Enn from the keypad PIN ONLY MODE 3 Enter 46 igit PIN lent to register Configuration PIN then 4 6 aigit PIN Enr to regist
35. values or modify your User Access list refer to section 12 for instructions on how to customize the operation of your unit 1 When User Access Card or PIN is granted Door RELAY activates for 3sec Green LED lights on for 3sec Ge 2 When User Access Card or PIN is not recognized Alarm RELAY activates for 2sec Red LED lights on for 2sec 0B 3 Duress Password 00 Duress Alarm to TTL output port for 03 sec 4 QUICK ACCESS MODE Disable 5 Chime Bell output Enable Chime Bell activation time 05 sec 3 4 5 6 Melody sound Enable 7 Keypad lock out time when Try Out error detected 01 min 8 9 10 11 8 Detect all inputs from H to L 9 Activate TTL output to L 10 Delay time to activate SECURE MODE 00 min 1 Door Open time out for Door Contact sensor 00 sec Number of times of Try out 05 times Input keypress time out time 20 sec Tamper Alarm Disable Tamper Alarm output port 02 Alarm Relay Toggle Mode Disable Unlock followed by Door Contact Disable 12 13 14 x 15 16 x 11 Operation 11 1 Normal Operation Mode Safe Mode When the Main Unit operates in normal mode the yellow LED is flashing every second 11 2 Open the Door When a registered Card or PIN is read the Door will open for 3 seconds along with the do mi sol do melody GBs S Registered Card or PIN 11 Star 100W IDTECX