Home

Infinity LX User`s Manual

image

Contents

1. Wo pas Codonics Infinity LX User s Manual 7 13 b Slide the hard drive out of the failed chassis o WOO o S only the front side edges and face with the label Do not handle the underside or the CAUTION Use care when handling hard drives Do not drop the hard drive Handle backplane of the drive Do not touch any exposed electronics 7 14 Maintenance A c Slide the hard drive fully into the corresponding slot in the replacement chassis Woe se CAUTION When installing the hard drive it is important to insert it all the way into its slot Push the drive as far into the slot as it will go it should be flush with the neighboring drives There is some resistance when the back of the drive is seated in the cage It is possible to latch the lever without having the drive fully installed It is critical that all drives are properly installed prior to the initial system startup of the replacement chassis CAUTION Make sure that each hard drive is installed in the corresponding slot in the replacement chassis Joe 000 a T B
2. Codonics Infinity LX User s Manua 7 15 doni fini 2 3 o 5 D 5 O d Close the hard drive lever to lock the drive in place The lever will click into position when it is fully closed and locked Aa p 1 40 a Woo sea lt 10 For both power supply modules a Release the power cord connector retaining clip ae D O O Te b Disconnect the power cord from the power supply module 7 16 Maintenance c Loosen the power supply module thumbscrew completely S Fole f 5 al z Coo 8 DA Toje d Pull the power supply from its slot using the attached handle e Insert the power supply into an empty slot in the replacement chassis f Tighten the power supply thumbscrew completely g Connect the power cord to the power supply h Secure the power cord with the retaining clip Codonics Infinity LX User s Manua 7 17 doni fini 11 Disconnect the Ethernet cable from the rear of the failed chassis and connect it to Ethernet port 2 of the replacement chassis 12 Remove the SmartDrive from the failed chassis and insert it into its USB slot i
3. Ready User ADMIN Mem used OK free 56 NUM 6 4 Managing Studies Selection Window The Selection window opens automatically when you start a Study Manager session or by clicking the button or 18 button in the Study Manager window toolbar From the Selection window you can e Search for patients or studies e Select patients or studies and then browse their related records studies if a patient is selected series images and reports aj Selection x File View Options g Study list 0 Desktop E Patient Name Patient ID Accession Number Study Date Series Modality Database From O w To CI MA v Q search in Database P Patient Name Patient ID Birthdate Sex Description Study Date Time lt gt o 2 o 2 le no 2 i 77 Codonics Infinity LX User s Manual 6 6 Data Sources The data that you manage using Study Manager is in the Infinity LX database This is the Database connection in the data source panel Data source panel aj Selection File Vlzw Options Database Panel listing data sources Patient List and Study List Tabs ay Study list O Desktop Patient Name oe OLIVER NADIA Study Date Time amp 5 27 2003 16 47 MR KNEE amp T Patient ID Birthdate 66524 12 19 1962 Accession No Study ID 165 165 448x448 1 Sex F 5 27 2003 Depending on how Study Manager
4. Sorting Data in the Selection Window To sort data listed in the Selection window by a column click the column heading Click the column heading again to reverse the sort order 6 8 Managing Studies Searching for Data ES 1 From the Selection window select the Infinity LX database that is Database in the data source panel where the data is stored To search for data Infinity LX database a Sdlection X Eile yew Options Study list D Desktop Patient Name Patient ID Accession Number Study Date Series Modality FonD oea gt Cpla Database Q Search in Database anal Z Patient Name Patient ID Birthdate Sex Description Dicom Server Images Selection window with a data source panel for selecting the data source 2 Enter search criteria for the data you want to find Codonics Infinity LX User s Manual D 5 D 5 a no 2 2 D o 6 10 In the Patient Name Patient ID and Accession Number fields enter all the search criteria to be matched or only the first one or more characters For example entering D in the Patient Name field will search for all last names beginning with D Search criteria fields aj Selection File View Options ay Study list 0 Desktop Patient Name Patient ID Accession Number Study Date 3eries Modality Database From o v To v gt All Q Search in Database CP
5. is 3 23 Chapter 4 Setting Up the Software LOO GING BARRES Re ee cizavasceens BAe 4 2 Logging In Using Remote Desktop Connection 4 2 Logging In Using a Local Monitor Keyboard and Mouse 4 6 Setting Up User Accounts ccccceeeeeeeeee eter eeeeeeeeteaeeteeeeeeteeeeteaeeteeieeenea 4 7 Preconfigured User ACCOUNTS 0 cccceeeeeneeeeeeeeeneeeeeeeeeaeeeeeeenaeeeeeneaaes 4 7 Changing a Users Password 4 8 Setting the Date and Time 4 12 Accessing the Infinity LX RSS Feed 4 12 Allowing DICOM Station ACCESS 4 13 DICOM Station Properties Identification Tab 4 18 DICOM Station Properties Grant Tab 4 20 DICOM Station Properties Import Tab 4 22 DICOM Station Properties Export Tab 0 cececeteeeeteeeeteeeees 4 26 Logging Out ssena ei nine Eea naaa UEN E aces Gaeta eles 4 28 Shutting Down and Rebooting 4 28 Shutting Down or Rebooting from a Remote Desktop Connection Or LOCAILY s secesiscceveinessses seeds heaviiniaaevecisecnetdibescedecieeesiteieaseeeceee 4 28 Shutting Down Using the Chassis Power Button 4 30 Removing Power to Infinity LX oo eee ceeeeeeeeneeeeeeeenaeeeeeeeeaeeeeeeeeaeeeeeteaas 4 32 Infinity LX SmartDrive sis 4 33 Codonics Infinity LX User s Manual vi Contents Chapter 5 Storing and Retrieving Configuring a Typical DICOM Host 5 1 Storing and Retrieving Studies 5 2 Testing DIC
6. e L oO Hard drive LL status light If you cannot find the hard drive with a red LED use the System Status tool to locate the failed hard drive a I x x Jens b 95 10 113732 100 12 Drives Location of failed drive drives Removing the wrong drive may result in data loss Contact Codonics Technical CAUTION If it is not apparent which hard drive has failed DO NOT remove any hard Support for assistance 1 440 243 1198 4 Open the failed hard drive s lever by pulling out on the blue tab to about 45 codonies Infinity LX User s Manual 7 3 This disconnects the hard drive from the internal connector _ Woo ee N 5 Wait 10 seconds for the hard drive to spin down 6 Slide the failed hard drive out of the chassis DORN A S 7 Mark the word FAILED on the failed hard drive to prevent accidental reuse hard drives Dispose of failed hard drives in an appropriate manner to protect patient CAUTION Electronic patient health care information may still be accessible on failed health care information 7 4 Maintenance 8 The replacement hard drive is shipped in a protective anti static bag Open the anti static bag and carefully remove the replacement hard drive properly grounded and observe anti
7. El itl x Not a tomographic image or irregular slice spacing Note that when Orthogonal View or MPR MIP protocols are launched if the application detects that there is not enough memory on the PC to run such protocols with full performance the user is prompted with the following message asking if a resampling is permitted Wituaady Not enough memory to run this protocol with Full performance 4 Do you want to resample the input Note that this will induce a loss in image quality J_w If the user accepts to resample the image quality will be altered by displaying only one pixel out of two on the X Y and Z axis The user may nevertheless decide to continue without resampling the image size but this will affect the performance of the protocol Refer to the following examples to see how rescaling affects the image Managing Studies W P i Fast Preview Fast Rotate Slice thickness 0 978 H Original Image Size Codonics Infinity LX User s Manual 6 37 D 5 D 5 e 2 o 2 O Fast Preview Fast Rotate Slice thickness f 956 Resampled Image Size 6 38 Managing Studies SUV Calculations With the Study Manager SUV Body Weight is computed using the following values e D injected dose Becquerels e tl time span between injection and acquisition seconds e T half life period of the radio isotope used seconds e W weight of the pati
8. 14 When prompted to confirm saving the DICOM stations click the Yes button Codonics Infinity LX User s Manual 4 17 n 2 2 i T gt D wn D p DICOM Station Properties Identification Tab Table 4 1 describes the station properties that can be set on the Identification tab shown below DICOM Station s properties Identification Grant Import Export Kind Workstation 4 Model Unknown 4 Alias CT Station 1 DICOM parameters AE Title CT_1 Host 192 168 1 100 Port 104 M Get IP address from incomming connection Secure connection Private DICOM tags lt none gt 4 M Check IP Address at connection Cancel ya NOTE The default settings indicated in the following table are the application defaults If a profile has been copied from an existing one the settings will match the source profile and not the application defaults Table 4 1 DICOM Station Properties Identification Tab Kind This field is for reference only at this time Choices are Unknown the default Modality Workstation PACS HIS RIS Archive Archive for key data Modality or Workstation are most commonly used 4 18 Setting Up the Software Table 4 1 DICOM Station Properties Identification Tab Property Description Alias A user defined name for this DICOM station This name is used for
9. name appears in the Study Manager destination selection list Infinity LX as a DICOM source 6 At the DICOM destination server configure support for You will have to define DxDCMserver as the Calling AE Title the Infinity LX IP address and 104 as the port number After configuring Infinity LX as a DICOM source on the destination source click the Test echo button on the General tab to test communication with the destination server You should receive a confirmation that the destination server successfully replied to the test message 8 Go to the Advanced tab DICOM configuration General Advanced Settings Study Root A Query C FIND a Wildcard character in search fields Append wildcard character to all strings Append wildcard character to Patient s Name and Patient ID on Append wildcard character to Patient s Name only Scheduling of queries Send a C ECHO command at initialisation phase oO Query images after queying the series In desktop O List all studies for a patient Move C MOVE La Move multiple objects Allow query with multiple SOP instance UIDs Prefer query at series level Prefer query at study level Transfer with Dx ImpExp Use Routing to export from PACS database Patient Root a Use Routing to import in PACS database v Managing Studies 9 Under Transfer with DxiImpExp select the following options Use Routing to ex
10. 07 Second Edition IEC 60950 1 2005 2nd Edition and or EN 60950 1 2006 Information technology equipment EMC EMI EN 55022 2006 Class B EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2006 EN 55024 1998 A1 2001 A2 2003 47 CFR Part 15 2005 15 107 and 15 109 Class B Interface Utilisateur Navigateurs soutenus Protocols de Serveur DICOM Stockage Performance Redondance Compression d image Alertes Status Notifications Assistance technique Ondulateur Antivirus Syst me d operation Processeur Memoire Disque Optique Interface Ethernet p cifications Francais Acces distance sur l internet et avec Windows Remote Desktop Accessoires en option moniteur clavier souris Internet Explorer 7 FireFox 3 DICOM 3 0 Store Storage Commit Query Retrieve 1 8 TB en utilisant des disques durs SATA II 3 5 in 50 MB sec DICOM Store Raid 1 mode mirroir pour le syst me d op ration et la base des donn es Raid 5 donn es principales Remplacement a chaud des disques durs Remplacement chaud des pi ces d alimentation 1 1 Remplacement a chaud des ventilateurs refroidissement Remplacement chaud de la disque dur en ligne avec une r p tition automatique optionnel Compression sans perte au format JPEG Lossless et compression avec perte au format JPEG Lossy optionelle Echec de disque chec de ventilateur refroidissement chec de bloc d alimentation alerte
11. 2009 amp System 10 1 90 165 Storage Network System Storage Hostname Tubby7 Network System IP Address 10 1 90 165 UPS Subnet Mask 255 255 0 0 Gateway 10 1 1 1 Main Chassis Drives Software Version 1 3 1 b 100 Free 7 8 TB Serial Number 115C00007C Temperature N License Code 055 00045 199 0 Used 0 0 TB 7 8 TB Total a S se 2a os O gt o o o aes so Te gt a Main Chassis Main Chassis Battery Level 100 0 7 8TB 13 HDD Information panels codonics Infinity LX User s Manual 8 5 Status Indicators The Dashboard and navigation tree include the following status indicators e Status icons Icons that provide basic information about the Infinity LX s operating state Hard drive UPS battery Chassis storage status status temperature a0 gt iv Wed Oct 22 a 17 51 EDT 10 1 137 32 100 13 Drives 50 0 C 2008 Network Hard drive status operating status e LED status indicators The three LED style lights indicate the overall status of Infinity LX rae Alert condition Infinity LX Ready Infinity LX is ready can still process jobs but to process requests requires user attention Critical or fault condition Infinity LX may or may not process jobs The system requires immediate user attention JA gt 4 E Wed Oct 22 r a 17 51 EDT 10 1 137 32 100 13 Drives 50 0 C 2006 8 6 Status Indicators and Troubleshooting e Navigation
12. 5 Ifa UPS is not being used Setting Up the Hardware 3 8 gt gt gt If the UPS is being used then refer to Installing the UPS Accessory on page 3 14 CAUTION Connect Infinity LX to only high quality electrical power Do not expose Infinity LX to suboptimal power conditions including but not limited to potential loss of power power spikes or over or under voltage conditions n i f 2 le i T gt o IT D a o o WARNING The two power cords connected to the UPS or a wall outlet are the main disconnect for Infinity LX WARNING To disconnect overall power to Infinity LX prior to servicing it shut down the system refer to Shutting Down and Rebooting on page 4 28 and then power down the device refer to Removing Power to Infinity LX on page 4 32 6 Connect the Ethernet cable to Ethernet port 2 gt v De Bip e Y Codonics Infinity LX User s Manual 3 9 Installing Hard Drives Y gt 1 To install a hard drive unpack the hard drive To install the hard drives properly grounded and observe anti static procedures before removing the hard drive from its anti static bag Do not drop the hard drive Handle only the front side edges and face with the label Do not handle the underside or the backplane of the drive Do not touch any exposed ele
13. Part 1 General Requirements UL 60950 1 Second Edition Dated March 27 2007 Information Technology Equipment Safety Part 1 General Requirements CAN CSA C22 2 No 60950 1 07 Second Edition IEC 60950 1 2005 2nd Edition and or EN 60950 1 2006 Information technology equipment EMC EMI EN 55022 2006 Class B EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2006 EN 55024 1998 A1 2001 A2 2003 47 CFR Part 15 2005 15 107 and 15 109 Class B Index A access remote via the web 4 2 admin user account 4 7 Administration tool 4 8 4 13 AE Title DICOM station identification property 4 19 6 43 AE Titles Infinity LX 5 1 perm 5 2 temp 5 2 Alias DICOM station identification property 4 19 audible status alarm 8 2 Automatic Copyback 2 6 c Called AE Titles 5 1 Called AE Titles Infinity LX perm 5 2 temp 5 2 C FIND granted DICOM station grant property 4 20 C GET granted DICOM station grant property 4 21 chassis cleaning 7 1 ordering 7 22 replacing 7 12 Check IP Address at connection DICOM station identification property 4 19 cine control Study Manager 6 26 cleaning precautions xxiv clipping box Study Manager 6 25 C MOVE granted DICOM station grant property 4 21 Codonics email address xii Codonics cont phone numbers xii product information xii website xii cold swap 2 6 compliance label location xiii Configuration name DICOM configuration property exporti
14. 3 21 O Only key images are visible DICOM station grant property 4 21 operator user account 4 7 Optimize Presentation Context Negotiation DICOM station export property 4 27 orthogonal display Study Manager 6 30 Orthogonal mode Study Manager 6 29 orthogonal views Study Manager 6 25 P PACS workstations 4 13 5 1 parity 2 4 passwords changing 4 8 patient folder icons 6 13 patient information precautions xxv Patient List tab 6 7 patient records viewing 6 14 perm AE Title 5 2 Port DICOM station identification property 4 19 Index Port number DICOM configuration property exporting records 6 43 power removing from Infinity LX 4 32 Power button location 3 4 power cords installing 3 7 power supplies location 3 5 power supply switch locations 3 5 status light locations 3 5 power supply modules ordering 7 22 replacing 7 9 troubleshooting 8 18 power supply status light 8 3 precautions cleaning xxiv location xxi maintenance xxv medical and patient information xxv safety xix to xxi primary image acquisition systems 4 13 5 1 printing troubleshooting 8 15 Private DICOM tags DICOM station identification property 4 19 Purge Temporary Studies system parameter 3 21 purpose of User s Manual xi radio frequency interference xviii radio interference xviii RAID controller 2 3 definition 2 2 operating modes 2 5 8 11 RAID 1 2 3 RAID 5 2 4 troubleshooting 8 18 rear panel
15. Dicom Server Patient Name Patient ID Birthdate Sex Description E Images Search button NOTE If no search criteria is entered all patients or studies from the data source will be listed Searching without criteria is not recommended as the data retrieval can require a large amount of time 3 Click the Search button Matching patients or studies from the data source are listed in the lower portion of the tab Managing Studies In the Patient List tab a list of matching patients is displayed r A Selection 3 Patients File View Options E f Patient list T Desktop f Patient Name Patient ID Accession Number Study Date Series Modality Database From O xmo gt gt an Q Searchi in Database Z Patient Name Patient ID Birthdate Sex Doe Jane 0274304559354794 8 13 2019 F Doe John 3236984559368482 11 7 2063 F Doe John CT 1111 10 21 1929 F Matching patients In the Study List tab a list of matching studies is displayed You might see more than one study belonging to the same patient fr A Selection 3 Studies Eile View Options a Study list D Desktop Patient Name Patient ID Accession Number Study Date Series Modality Database From O v To o gt lan v Q search in Database Patient Name s Patient ID Birthdate Sex Description Doe John CT 1111 10 21 1929 F KIDNEY Doe John 3236984559368
16. components shown in the following illustration Chassis 8 Key SmartDrive Software Installation and Users Manual discs Documentation Unpacked Infinity LX components Inspect the carton for damage that might have occurred during shipping Report any damage to the shipping company Save the carton and packing materials in case you ever need to transport Infinity LX later 3 2 Setting Up the Hardware properly grounded and observe anti static procedures before removing the hard drive from its anti static bag Do not drop the hard drive Handle only the front side edges and face with the label Do not handle the underside or the backplane of the drive Do not touch any exposed electronics CAUTION Use care when unpacking and handling hard drives You should be n 2 le i T gt D IT D a o p Codonics Infinity LX User s Manual 3 3 Infinity LX Front Components The following illustration shows the components at the front of Infinity LX with the hard drives installed Disc drive Front door Power button Status lights Mute button aE a SmartDrive Hard drive Hard drive slots status lights lll Infinity LX front panel components e Opening the Front door provides access to the front panel component
17. 17 If there is a UPS power on the UPS 7 20 Maintenance 18 Turn the power supply switches on the two power supplies to On Power supply status light yee Both power supply status lights should be illuminated green 19 Momentarily press the power button at the front of the replacement chassis to start up Infinity LX o Power button E O Cp oi a ANAM FAAAM TANAAN MIT O Q Jo o o Codonics Infinity LX User s Manual 7 21 2 3 5 D 5 O o ordering Parts 7 22 Maintenance The following table lists the replacement parts that can be ordered from Codonics Supplies Catalog Number Infinity LX hard drive 1 TB SP 00436 Infinity LX power supply SP 00437 Infinity LX chassis SP 00438 To order parts in the U S A contact Codonics Customer Service at Phone 440 243 1198 Fax 440 243 1334 Toll Free 800 444 1198 Web www codonics com To order parts outside of the U S A contact your Codonics representative G installing Infinity LX Software 2 3 o 5 D 5 O If you have to reinstall Infinity LX software due to a system problem or are installing a software upgrade use the following general procedure install other software applications This includes unauthorized anti virus software Installation of unauthorized softwa
18. 6 48 records editing 6 41 records exporting 6 42 to 6 47 records exporting procedure 6 46 records viewing 6 40 reinitialize the volume 6 24 Reslice mode 6 20 searching for data 6 9 selecting patients to view 6 12 selecting studies to view 6 12 slice thickness 6 22 slices reconstructed 6 30 starting 6 2 SUV calculations 6 39 Triple Orthogonal mode 6 34 views switching 6 24 volume rotation enabling 6 24 window level options 6 32 Study Started DICOM station import property 4 25 Subnet Mask network parameter 3 21 Supports Key Object Selection Documents DICOM station grant property 4 21 Supports Other Objects DICOM station export property 4 22 Supports Presentation States DICOM station grant property 4 21 Supports Structured Reports DICOM station export property 4 21 SUV calculations Study Manager 6 39 system information configuring 3 19 to 3 22 system log files 8 22 System Name network parameter 3 21 System parameters 3 21 system problems 8 15 Index System Status user interface 8 4 to 8 11 detailed information 8 10 Drives Legend 8 11 navigating detailed status information 8 9 navigation tree icons 8 7 starting 8 4 status indicators 8 6 T television interference xviii temp AE Title 5 2 terabyte 2 1 time setting 4 12 To email parameter 3 21 Triple Orthogonal mode Study Manager 6 34 troubleshooting 8 15 to 8 20 general system problems 8 15 hard drives 8 18 power 8
19. D wn D p 7 Select the user to change and click the Edit button Select a user Click Users eile View Action Help ad n Setup Bo Jeg OPERATOR Delete Associated Role The User dialog box displays 8 Enter and confirm the new password Enter the password r Login r Associated services Name M Code Name There are no items to show in this view Password D Password expired user must change password on next login m Identification Name ID o aR D ECS Fit Middle Sue of gt Phone Intemet wok Mobs fo NN i i JE Ernie Select All Unselect All Filter Last modified 2008 10 21 8 53 38 by ADMIN OK Cancel Click OK 9 Click the OK button 4 10 Setting Up the Software 10 Click the Save All button Click Save All i Aliministration Users G Fle view Action Help S amp Users le Roles Services 48 Views List of Users Full Name Add Cop Edit Delete Associated Role 11 When prompted to confirm saving the users click the Yes button o 2 i T gt D o D p Next you have to change the Windows passwords for the corresponding user accounts 12 On the Start menu click Control Panel 13 Double click the User Accounts tool The User Accounts window displays 14 For each Windows user account change th
20. Infinity LX Medical Image Server We are pleased you chose Infinity LX We are confident that it will provide fast reliable storage of medical images for your demanding data storage and distribution applications Codonics Infinity LX User s Manua 1 1 doni fini 5 e a c O fe 1 2 Product Features Introduction Infinity LX is an expandable DICOM storage appliance that provides a simple solution for storing and retrieving medical images Applications such as direct modality storage of large DICOM data sets or storage of digital images in an environment without a centralized image server are ideal for Infinity LX Infinity LX makes the power of complicated rack mounted servers available to users without special IT skills With an intuitive interface and many preconfigured features users can set up and maintain their own Infinity LX image servers Infinity LX can also grow as your business grows The high reliability RAID based architecture allows storage and capabilities to be added incrementally Infinity LX is backed by Codonics global service and support network to provide years of worry free operation Temporary Modality Storage The Infinity LX unique design delivers performance and reliability in an easy to use package This makes Infinity LX an ideal storage solution for large temporary datasets from CT MR and other DICOM modalities Thin slices raw data optio
21. MODEL MODELE INFINITY 1 Infinity LX safety and compliance label Codonics Infinity LX User s Manual xii Preface Safety and compliance label location Infinity LX safety and compliance label on right side of chassis Voltage Warning The exclamation point within a triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying this device A REFER SERVICING TO QUALIFIED SERVICE PERSONNEL REMOVAL OF LABELS COVERS OR ENCASEMENT FASTENERS MAY VOID THE WARRANTY THIS APPARATUS MUST BE ELECTRICALLY GROUNDED TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS DEVICE TO RAIN OR MOISTURE gt gt EQUIPMENT IS NOT TO BE USED AS A COMPONENT OF A LIFE SUPPORT SYSTEM Life support devices or systems are devices or systems that support or sustain life and whose failure to perform can be reasonably expected to result in a significant injury or death to a person A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness WARNING The two power cords connected to the uniterruptible power supply UPS or a wall outlet are the main disconnect for Infinity LX WARNING To disconnect overall power to Infinity LX prior to servicing it shut down
22. NPR mp 2 E ow I Fast Preview J Fast Rotate Slice thickness 0 978 o 2 o e 2 Le a E oO 77 Codonics Infinity LX User s Manual 6 19 6 20 Dockable Toolbar Options Reslice Mode To toggle the reslice mode click the button e Single oblique button not pressed reslice the volume in a single oblique orientation Click on one of the blue lines and wait until the cursor turns into a rotation arrow Drag the line to the desired angle The intersection of the new slices with the two other views will automatically be updated and reset to an orthogonal angle The reconstructed series will display the center slice of the new series Double oblique button pressed reslice the volume into any oblique orientation Click on one of the blue lines and wait until the cursor turns into a rotation arrow Drag the line to the desired angle The intersection of the new slices with the two other views will automatically be updated Set the orientation on the other views by rotating the blue line The reconstructed series will display the center slice of the new series Managing Studies Layouts To toggle between a 2x2 layout or a 3x1 1 layout click the or button respectively In the 2x2 layout the orthogonal views are arranged in a 2x2 mosaic and the reconstructed series is displayed in the lower right image box In the 3x1 1 layou
23. Support 1 440 243 1198 Remove unnecessary studies or increase storage capacity For additional information or assistance contact Codonics Technical Support 1 440 243 1198 Table 8 5 Troubleshooting Continued Problem Possible Causes Data is being restored to An Automatic Copyback from the hot a hard drive An array is being built spare drive is being performed on a newly installed hard drive The initial build of a RAID array is being performed either during a full system install or because a new bank of hard drives was installed The hot spare drive is ina The hot spare drive has either failed or fault state is not installed A hard drive in an array is The drive has either failed or is not in a fault state installed properly A hard drive in an array is The drive has either failed or is not inafault state andthe hot installed and the hot spare drive is spare drive is not available currently rebuilding in response to another failed or removed drive or performing an Automatic Copyback to a newly installed hard drive Solutions No action is required CAUTION Do not remove any hard drives or shut down Infinity LX until the restore operation is completed No action is required CAUTION Do not send studies remove any hard drives or shut down Infinity LX until the build operation is completed Replace or reinstall the hard drive in slot 13 refer to Replacing a Har
24. button 4 2 Setting Up the Software The Remote Desktop Connection options dialog box displays On the Experience tab change the connection speed to LAN 10Mbps or higher Remote Desktop Connection General Display Local Resources Programs Experience Performance Q Choose your connection speed to optimize performance LAN 10 Mbps or higher Connection speed options Allow the following Desktop background Show contents of window while dragging Menu and window animation Themes Bitmap caching o 2 2 i T gt D wn D p Cancel Help Options lt lt Codonics Infinity LX User s Manual 4 3 4 4 4 On the Display tab change the Color to True Color 24 bit or True Color 32 bit General Display Local Resources Programs Experience Remote desktop size EM Choose the size of your remote desktop Drag the slider all the way to the right to go fullscreen Less More Full Screen Colors True Color 24 bit v Note Settings on the remote computer might override this setting M Display the connection bar when in full screen mode Setting Up the Software Display color options 5 On the General tab enter the Infinity LX IP address Remote Desktop Connection a General Display Local Resources Programs Experience Logon settings Type the name of the computer or choose a computer f
25. de surchauffe tat d onduleur Web email RSS d alertes visuelles et audibles Assistance technique a distance sur l internet service LogMeln Rescue Ondulateur d assistance tout int gr avec une fermeture automatique optionnel Factory installed Windows XPe Processeur Intel Core 2 Duo 2GB CD DVD 2 100 1000Base T Ethernet a detection automatique RJ 45 Codonics Infinity LX User s Manual wn Q Ey O D re 5 D B 4 Interface Serie Alimentation Temperature Humidit Dimensions Poids Conformit m dical La s ret les missions et l immunit lectrique Specifications 2 ports USB 2 0 host side du panneau avant 1 port USB du panneau avant r serv au disque dur SMART 6 ports USB 2 0 host side du panneau arri re 1 port s rie RS 232 Global d entr e 100 240 Vac 50 60 Hz 650 W Op ration 15 30 C 59 86 F Stockage 22 2 51 C 8 123 8 F Op ration 20 80 sans condensation Stockage 85 maximum sans condensation Hauteur 42 9 cm Largeur 66 cm Profondeur 22 1 cm Chassis principal shipped 36 7 kg Disques durs shipped 12 7 kg Ch ssis principal disques durs installed 41 7 kg FDA Medical Device Class 1 manufactured in compliance with FDA GMP QSR 1 013485 2003 CE MDD 93 42 EEC compliance for Healthcare Facilities subject to installation guidelines Information Technology Equipment Safety
26. descriptive purposes only and is not used in DICOM communications Model This option is not currently supported leave the default selection Unknown AE Title The AE Title of the DICOM station Two DICOM stations cannot have the same AE Title and host name in this field Host Host name or IP address of the DICOM station g Port TCP port number where the DICOM station is waiting for a images 5 The TCP port number must be 104 3 fe This field is mandatory when the host field is specified F o Get IP address from This option is not currently supported and should not be o incoming connection selected Secure connection This option is not currently supported and should not be selected Check IP Address at This option is not currently supported and should not be connection selected Private DICOM tags This option is not currently supported leave the default selection lt none gt Codonics Infinity LX User s Manual 4 19 4 20 DICOM Station Properties Grant Tab The Infinity LX DICOM server supports different DICOM services When defining a new DICOM station various DICOM services can be revoked or granted for this station For instance for a modality that will store images in Infinity DICOM Server only the C STORE is mandatory Table 4 2 describes the station properties that can be set on the Grant tab shown below DICOM Station s properties Identification i 1 Import Export Services C
27. gt CODONICS We bring the future into focus Infinity LX Medical Image Server User s Manual Codonics Catalog Number INFLX MNLU April 16 2010 Version 1 3 1 Codonics Inc 17991 Englewood Drive Middleburg Heights OH 44130 USA 440 243 1198 Phone 440 243 1334 Fax email info codonics com www codonics com Copyright 2008 2010 by Codonics Inc All rights reserved worldwide Printed in the U S A Part Number 905 058 007 No part of this document may be copied or reproduced in any form by any means without prior written consent of Codonics Inc 17991 Englewood Dr Middleburg Heights Ohio 44130 U S A Although every effort has been made to ensure the accuracy of this document Codonics Inc assumes no responsibility for any errors that may appear Codonics Inc makes no commitment to update nor to keep current the information contained in this document Patent Pending All Rights Reserved Codonics the Codonics logo Infinity and We bring the future into focus are registered trademarks of Codonics Inc Microsoft is a registered trademark of Microsoft Corporation in the United States and or other countries Firefox is a trademark of the Mozilla Foundation All rights reserved ClamAV is a trademark of Sourcefire Inc Intel and Pentium are trademarks of Intel Corporation in the U S and other countries LogMeIn Rescue is a trademark of LogMeln Inc and may be registered in the U S Patent and Tradem
28. hardware 3 7 to 3 18 installing Infinity LX software 7 23 interference radio and television xviii IP Address network parameter 3 21 J JPEG compression settings exported images 4 27 imported images 4 23 K keyboard connecting 3 18 Kind DICOM station identification property 4 18 L laser warnings xvi layouts Study Manager 6 21 LED status lights interpreting 8 3 Locale system parameter 3 21 location for Infinity 3 1 location precautions xxi log out 4 28 login procedure local monitor keyboard and mouse 4 6 Remote Desktop Connection 4 2 LogMeln Rescue 8 21 logs system 8 22 maintenance 7 1 to 7 24 precautions xxv manager user account 4 7 Matching DICOM station import property 4 24 measurements Study Manager 6 32 medical information precautions xxv MIP display Study Manager 6 30 Codonics Infinity LX User s Manual 1 3 1 4 MIP mode Study Manager 6 23 mirroring 2 3 modality workstations 4 13 5 1 Model DICOM station identification property 4 19 monitor connecting 3 18 Mosaic Only mode Study Manager 6 35 mouse connecting 3 18 MPPS granted DICOM station grant property 4 21 MPR mode Study Manager 6 19 Mute button 8 2 Mute button location 3 4 Name AE Title DICOM configuration property exporting records 6 43 Near line objects access granted DICOM station grant property 4 21 network activity status lights 8 3 Network panel 3 20 Network parameters
29. has been configured for your site you can list search results by patient or study Study Manager can be configured to display either the Patient List or Study List tab or both in the Selection window Managing Studies In the Patient List tab a list of patients is displayed Patient List tab al Selection 3 Patibnts File View Options a Patient list D Desktop g E Patient Name Patient ID Accession Number Study Date Serie Q Search in Database Patient Name Patient ID Birthdate Sex amp Doe Jane 0274304559354794 8 13 2019 F amp Doe John 3236984559368482 11 7 2063 F Doe John CT 1111 10 21 1929 F In the Study List tab a list of studies is displayed Note that there might be more than one study belonging to the same patient Study List tab a Selection 3 Stu lies File View Options a Study list fo Desktop aes Patient Name Patient ID Accession Number Study Date Serie Database dos From O v Tol x gt al Q Search in Database Patient Name Patient ID Birthdate Sex Description Doe John CT 1111 10 21 1929 F KIDNEY E Doe John 3236984559368482 11 7 2063 F BRAIN Doe Jane 0274304559354794 8 13 2019 F HEART D 5 D 5 a no pha 2 7 Codonics Infinity LX User s Manual ty Study Manager Desktop Tab The Study Manager Desktop tab lists the records related to the
30. methods used to send studies to and retrieve them from Infinity LX ya NOTE When sending studies to Infinity LX it is recommended that you use Storage Commit This method causes Infinity LX to send a confirmation message back to the DICOM station when the studies have been successfully stored in the Infinity LX database Infinity LX supports the standard Called AE Titles described in the following table Table 5 1 Infinity LX AE Titles Called AE Title TCP Port Description temp 104 Place studies in temporary storage perm 104 Place studies in permanent storage for primary diagnostic interpretation While providing tools for display and data CAUTION Infinity LX is a Class 1 Medical Image Storage Device and is not intended AN management the Study Manager is not a diagnostic workstation 5 2 Storing and Retrieving Q iesting DICOM Store and Retrieve Infinity LX is a DICOM Storage Class SCP Service Class Provider and a DICOM Query SCU Storage Class User C Move SCP As such Infinity LX can be configured to accept incoming DICOM Store associations as well as incoming DICOM Query Retrieve requests Any system that supports DICOM Store and or Query Retrieve should work with the Infinity LX Typical DICOM stations that would connect to the Infinity LX include e Modality workstations e PACS workstations e Primary and secondary image acquisition systems For configuration of a typical DICOM station for connectio
31. of the chassis C Codonics Infinity LX User s Manual 3 23 wn D f 2 Le i T gt D IT 2 a o D 4 Insert the SmartDrive into its USB slot at the front of the chassis Power button E O O O m Jo o o 6 Wait approximately 5 minutes for startup to complete There are six audible beeps when startup is complete Power light N H o o Jo o o 3 24 Setting Up the Hardware ya NOTE To shut down and power down Infinity LX refer to Shutting Down and Rebooting on page 4 28 and Removing Power to Infinity LX on page 4 32 n i f 2 le i T gt o IT D a o Lu Codonics Infinity LX User s Manual 3 25 gt gt Setting Up the Software This chapter includes the information you will need to set up Infinity LX software e Changing the password for the preconfigured user accounts e Setting the system date and time e Accessing the Infinity LX RSS feed n i 2 i T gt o wn D oO e Setting up access to Infinity LX for DICOM stations CAUTION Only trained users should install and configure the system CAUTION Do not reconfigure or mod
32. patients or studies that are selected in the Patient List or Study List tabs From the Study Manager Desktop tab you can browse a patient s studies series images and reports and select the data you want to view or work with Study Manager Desktop tab a Selection Eile view Options a Study list 0 Desktop a E E DEE lt Patient Name Patient ID Birthdate Sex pines amp oe Doe John CT 1111 10 21 1929 F Study Date Time Description Accession No Study ID E Sy 11 8 2071 05 04 KIDNEY 2326824559390747 2326824559390746 am DG SERIES 2 102x102 10 8 20 1920 21 10 a DG SERIES 1 102x102 10 12 6 1972 06 52 EL 1984 01 46 LC 1 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 34 O 2 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 35 O 3 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 36 O 4 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 37 UO 5 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 38 O 6 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 39 UO 7 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 40 O 8 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 41 O 9 102102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 42 O 10 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 43 am DG SERIES 3 102x102 10 9 20 2025 00 12 aM DG SERIES 5 102x102 10 12 26 2072 11 55
33. powered on refer to Starting Up Infinity LX on page 3 23 The Windows login should be displayed on the monitor Log On to Windows Copyright 1985 2001 Microsoft Corporation User name admin E Enter the username admin Password Enter the password the default is codonics Click OK Enter the administrator user name admin Enter the administrator password the default is codonics Click the OK button A Windows session is started and the Windows desktop displays For information about how to log out shut down the system or reboot the system refer to Logging Out on page 4 28 and Shutting Down and Rebooting on page 4 28 Setting Up the Software g QSetting Up User Accounts User accounts define the login names and passwords that can be used to login to a Windows session on Infinity LX and to access the Infinity LX applications along with the function privileges that the user has within those applications Preconfigured User Accounts The following user accounts are preconfigured to allow access to the Infinity LX applications admin which provides full access to all functions e manager which provides access to view modify and delete studies in the database using the Study Manager tool n i 2 i T gt o wn D oO e operator which provides access to view and store studies in the database using the Study Manager tool The de
34. static procedures before removing the replacement hard drive from the anti static bag Do not drop the hard drive Handle only the front side edges and face with the label Do not handle the underside or the backplane of the drive Do not touch any exposed electronics CAUTION Use care when unpacking and handling hard drives You should be 9 Locate the drive number labels in the replacement hard drive kit Peel off the number that corresponds to the failed hard drive and attach the label to the new hard drive Codonics Infinity LX User s Manual 7 5 2 3 5 D 5 O o 10 Pull down on the blue tab to open the replacement drive lever to about 45 Wow ee slot Push the drive as far into the slot as it will go it should be flush with the neighboring drives There is some resistance when the back of the drive is seated in the cage It is possible to latch the lever without having the drive fully installed CAUTION When installing the hard drive it is important to install it all the way into its 7 6 Maintenance 12 Close the hard drive lever to lock the drive in place The lever will click into position when it is fully closed and locked Le OS 8 UX s 6 o W NOTE After installing a new hard drive its status light m
35. study series image or report to be deleted Open the File menu and click Delete Then click the parent record level at which you want to perform the deletion For example if a series is selected you can click Patient s or Study ies to delete the entire patient or study in which the series is contained You are prompted to confirm the deletion Click the Yes button The record its sub records and its selected parent records are deleted Managing Studies Exiting Study Manager Y gt In the File menu click Exit To exit Study If there were edits made to any of the images you will be prompted Manager to save any unsaved changes D 5 D 5 a no a Q D o Codonics Infinity LX User s Manual 6 49 2 3 o 5 D 5 O lt gt Maintenance Backing Up Study Data To prevent loss of the study data it is strongly recommended that this data be backed up to another device on a regular basis For information on data backup options for example sending studies to Virtua and burning discs contact Codonics Technical Support 1 440 243 1198 CCleaning fhe Chassis Enclosure To clean the Infinity LX chassis enclosure log out shut down and power down the system refer to Logging Out on page 4 28 Shutting Down and Rebooting on page 4 28 and Removing Power to Infinity LX on page 4 32 When it is powered off turn off the two power supply switches on the rear
36. system WARNING Because Infinity LX is over 81 Ibs 36 kg without the drives and over 90 Ibs 40 kg with the drives installed use caution when lifting or moving the chassis Installing Power Cords Ethernet Cable and SmartDrive Unpack the hardware and remove any packing material N Place Infinity LX on a solid level surface 3 Ensure that the power supply switches are turned off C eTO JO Codonics Infinity LX User s Manual 3 7 wn iv f 2 Le i T gt IT 2 a o D Retaining clip connect the power cords to a wall gt d 2505070 a Fos TD ROB ORR ORO BESZORDBOEORO I 2E BOBOBOBOLOR OROTZ OOOO amp ORSEORORDROLEERELO a OEOROLOTS LOG BEERS amp PBORWRORTLORRERSRS ED SEO aise PERO FERS RO g 802080080800 08000 QZOBOSPLOROLGROLSRO GLOBELOLOLGLOLEQILS BOBOBQRORQSOROBOBORORORORO BREQELSLERSRERBREREREQEQECS OROBORLOEOROEOROZOBOLOEORO BOLOROBOLOZOLOLOLORLORORG oO RLOLELOLOLSLSELSLSLOLSLOLO 4 Connect the power cords Secure the power cords with the attached clips outlet r NOTE It is highly recommended that a UPS be used with Infinity LX
37. toujours arr ter le syst me et aussi l appareil e Un cordon d alimentation endommag est une cause d incendie ou de d charge lectrique En d connectant le cordon d alimentation tenez le seulement par la prise et retirez la prise soigneusement Si un cordon d alimentation ou un bloc d alimentation doit tre remplac utilisez un cordon d alimentation ou un bloc d alimentation Codonics fabriqu sp cifiquement pour votre appareil Si l appareil fume ou met des bruits inhabituels arr tez le imm diatement et d branchez le c ble secteur e Nintroduisez aucun objet tranger dans l appareil cela peut tre une source de danger et peut causer de graves dommages e Ne d posez aucun r cipient cot de l appareil Si pour une raison quelconque un liquide est renvers l int rieur arr tez imm diatement l appareil et d branchez le c ble secteur Toute nouvelle utilisation de l appareil sans intervention peut causer de graves dommages Ne pas utiliser l appareil cot d une source de gaz inflammable Location Precautions e Because Infinity LX is over 90 Ibs 40 kg with the drives installed use caution when lifting or moving the chassis e The device s operating ambient temperature range is 15 30 C 59 86 F with a relative humidity of 20 80 e If the device is moved quickly from an extremely cold place to a warmer one condensation is likely to form Do not use the device if condensati
38. tree icons Icons that provide basic information about Infinity LX s operating state System 10 1 137 32 Storage Network System UPS Main Chassis Drives Temperat A The following tables explain how to interpret the state of the status and navigation tree icons and of the LED indicators Table 8 2 Status and Navigation Tree Icons Status Icon Description iv A green checkmark in a status icon indicates a normal a operating condition entry indicates an alert condition An alert condition occurs when Infinity LX requires user attention but can still process storage and retrieval requests The specific alert condition is displayed in the Dashboard status message area and in the information panel area A yellow triangle in a status icon and next to a navigation tree Main Chassis Drives Temperature Examples include the internal temperature of the chassis exceeding the alert threshold a hard drive being rebuilt or storage space is nearly full flashing next to a navigation tree entry indicates a critical condition A critical condition occurs when Infinity LX is at risk of entering a fault condition The specific critical condition is displayed in the Dashboard status message area and in the information panel area The combination of a red cross in a status icon and a red cross Main Chassis Drives X Temperatur Examples include that Infinity LX is running on UPS battery power o
39. 1 Turn the power supply switch of the new power supply module to On Power supply status light The power supply status light should be illuminated green Codonics Infinity LX User s Manual 7 11 2 3 5 D 5 O o IF To replace the chassis 7 12 Maintenance Replacing the Chassis Unpack the Infinity LX replacement chassis Place the replacement chassis on a flat solid surface near the original Infinity LX Remove the tape securing the front cover The interior of the replacement chassis has empty hard drive and power supply module slots The hard drives the power supply modules and the SmartDrive will be transferred from the failed Infinity LX chassis Shut down the failed chassis Refer to Shutting Down and Rebooting on page 4 28 When shutdown is complete turn the two Infinity LX power supply module switches at the rear of the chassis to Off e pes If there is a UPS power it off a 7 Disconnect the power cords from the power outlet or UPS Open the front door of the failed chassis 9 For each hard drive in the failed chassis a Open the hard drive s lever by pulling down on the blue tab to open the lever to about 45 This disconnects the hard drive from the internal connector p 00 2 3 5 D 5 O o
40. 18 print jobs 8 15 RAID 8 18 startup 8 15 UPS installing 3 14 troubleshooting 8 18 usable storage 2 1 USB port locations rear panel 3 6 Use Storage Commitment DICOM station export property 4 27 user accounts preconfigured 4 7 setting up 4 7 User s Manual purpose xi V VGA port location 3 6 views switching Study Manager 6 24 voltage warning xiv volume rotation enabling Study Manager 6 24 w warnings laser xvi voltage xiv web access remote 4 2 WEEE Waste Electrical and Electronic Equipment disposal directive xxvii window level options Study Manager 6 32 Codonics Infinity LX User s Manual 1 7
41. 2 35 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 36 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 37 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 38 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 39 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 40 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 41 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 42 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 43 SERIES 3 102x102 10 9 20 2025 00 12 SERIES 5 102x102 10 12 26 2072 11 55 Patient ID CT 1111 Birthdate Sex 10 21 1923 F Description Accession No Study ID 2326824559390747 2326824559390746 Study and its contents expanded An icon is used to identify each record as described in the following table Table 6 2 Record Icons Icon g Managing Studies Record Patient Study Series Image Information Listed Last name First name Date of birth Patient ID Creation date Creation time Study ID Procedure description Modality Series description lt Number of columns gt x lt Number of lines gt Number of frames Creation date Creation time Image number lt Number of columns gt x lt Number of lines gt Number of bits for one pixel if the image is in grayscale Number of frames DICOM instance UID Table 6 2 Record Icons Icon Record Information Listed 9
42. 482 1147 2063 F BRAIN Doe Jane 0274304559354794 8 13 2019 F HEART Matching studies If only one matching patient or study is found it is automatically selected and displayed in the Study Manager Desktop tab o 2 o 2 le no 2 i 77 Codonics Infinity LX User s Manual 6 11 QGelecting Patients or Studies to View With the matching patients or studies displayed in the Patient List or Study List tab you can select one or more entries and then browse their records in the Study Manager Desktop tab TS From the Patient List or Study List tab double click an entry To select a You can also select the entry Ctrl click to select multiple patient or entries open the File menu and click Open study to view in the Display Le tab Aj Selection 3 Patients Eile View Options a Patient list D Desktop Patient Name Patient ID Accession Number Study Date Series Modality Database T 2 doe From O O gt all x Q Search in Database GD Patient Name Patient ID Birthdate Sex amp Doe Jane 0274304559354794 8 13 2019 F Doe John 3236984559368482 11 7 2063 F Doe John CT 1111 10 21 1929 F Double click an entry to open its records in the Study Manager Desktop tab 6 12 Managing Studies The Study Manager Desktop tab displays The patients that correspond to the selected patients or studies in the Patient List or Study List
43. 8 EC The EN 50419 symbol indicates separate collection and return required EN 50419 symbol G indications for Use The Infinity Series of Medical Image Servers are Class 1 FDA 892 2020 medical image communications and storage appliances The Infinity product integrates software and server hardware to provide DICOM digital images and data storage and retrieval from various sources including but not limited to CT MR US NM PET CR DR secondary capture film digitizers workstations and import gateways Data can be stored managed and forwarded via software provided on the appliance including non primary interpretation review management of images on the server and via optional web enabled JPEG and web DICOM image delivery Codonics Infinity LX User s Manual xxvii xxviii Preface Users of this system are trained medical professionals including but not limited to physicians nurses and radiological technicians Those users responsible for the setup operation and maintenance of the system may include radiology technologists PACS administrators and IT personnel Primary applications include temporary and quarantine storage of large DICOM data sets directly from any modality and permanent storage of digital images in a pre PACS environment with security and transaction logs to support patient confidentiality audit compliance Introduction Welcome and Congratulations Congratulations on your purchase of the Codonics
44. FIND granted C STORE granted C MOVE granted C GET granted Storage Commitment granted MPPS granted Access O Only key images are visible O Near line objects access granted Objects O Supports Presentation States O Supports Key Object Selection Documents O Supports Structured Reports O Supports Other Objects HEH Cancel NOTE The default settings indicated in the following table are the application defaults If a profile has been copied from an existing one the settings will match the source profile and not the application defaults Table 4 2 DICOM Station Properties Grant Tab Property Description C FIND granted Select this option the default to allow the DICOM station to browse the Infinity DICOM Server s database C STORE granted Select this option the default to allow the DICOM station to push images to Infinity DICOM Server It is the minimum grant for a modality Setting Up the Software Table 4 2 DICOM Station Properties Grant Tab Property Description C MOVE granted Select this option the default to allow the DICOM station to retrieve images from Infinity DICOM Server Host and port must be defined C GET granted Select this option the default to allow the DICOM station to retrieve images from Infinity DICOM Server Host and port must be defined since the query and the transfer is done on the same association refer to the DICOM standard for more informatio
45. Failed 2008 p 13 Drives 50 0 C Information CPU Fan Failed auto limit Perform These Steps Contact Support Email Support support codonics com Web Address http www codonics com Codonics Technical Support is available at 1 440 243 1198 1 800 444 1198 Note that when in an alert critical or fault state the panel border color indicates the status of the related area yellow for alert and red for critical or fault E System 10 1 137 32 Storage Network System UPS Main Chassis Drives X Temperature Drives Legend Ready Rebuilding Failed Missing Empty v i 95 10 1 137 32 100 Rebuilding Status Indicators and Troubleshooting e Wed Oct 22 17 52 EDT Drive Failure 2008 amp fj 12 Drives 50 0 C Information Drive Failure pport The contact Contact Support Email Support support codonics com Web Address http www codonics com Codonics Technical Support is available at 1440243 1198 1 800 444 1198 When the Chassis or Drives navigation tree entry is selected a Drives Legend displays in the navigation panel The legend describes what drive states are indicated by the drive slot colors Drives Legend Ready Rebuilding Failed Missing Empty Table 8 4 describes the drive states listed in the Drives Legend Table 8 4 RAID Operating Modes Drive State Description Action Required Ready The drive is operating normally N
46. ICOM station Specific details about how to search the database on the DICOM station are usually found in the product s documentation a 5 D 5 2 J a 5 Co Codonics Infinity LX User s Manual 5 5 Managing Studies This chapter describes the Study Manager tool and includes information needed to Start and end a user session Search for data Select and browse data View images View reports View and edit records Export records Delete records Qstudy Manager Overview Study Manager is a full service DICOM client provided for image management and Quality Assurance Study Manager enables you to connect to the Infinity LX database and search for data related to patients studies series images and reports Once a search is performed you can select and view a record s data edit its database information or delete it Viewing tools while comprehensive are not intended for primary interpretation purposes Codonics Infinity LX User s Manual 6 1 D 5 D 5 a no a Q D o Starting a Study Manager Session YP 1 Locate the Study Manager icon on the Infinity LX desktop To start a Study Manager Study icon Manager session caa 2 Open Study Manager You are prompted to connect to the Infinity LX database Connection to the Database ql Please enter your name and password if you want to be connected to the database User ADMIN P
47. Image Server Keep such RF communications equipment out of the immediate area Potential for Radio and Television Interference The Codonics Infinity LX Medical Image Server generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The device has been type tested and found to comply with Class B emission limits for a computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operating in a commercial environment Operation of the equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be appropriate to correct the interference If your device does cause interference to radio or television reception you are encouraged to try to correct the interference by one or more of the following measures e Reorient the receiving antenna e Relocate the device with respect to the receiver If necessary you should consult Codonics Technical Support or an experienced radio television technician for additional suggestions You may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is avai
48. Infinity LX provides an RSS feed for delivering updates to the system status information that is also made available in the System Status tool Each RSS feed update is represented as an article The title and description of the article indicate the nature of the Infinity LX status change Many RSS feed readers are available and are built in to most current web browsers such as Internet Explorer 7 and Firefox 3 For information about how to access the Infinity LX RSS feed refer to Accessing the Infinity LX RSS Feed on page 4 12 2 8 Terms and Concepts n i f 2 le i T gt o IT D a o o Setting Up the Hardware G Finding a Location When finding a suitable location for Infinity LX use the following guidelines e Place Infinity LX on a flat hard surface and in a location with adequate air circulation to prevent internal heat build up e Do not place Infinity LX near heat sources such as radiators or air ducts or in a location subject to direct sunlight excessive dust mechanical vibration or shock e Do not block ventilation on the sides or rear of Infinity LX e Make sure that the countertop or work surface will not vibrate or shake when Infinity LX is operating For additional location precautions refer to Location Precautions on page xxi Codonics Infinity LX User s Manual 3 1 dE Unpacked Components Infinity LX is shipped in several cartons which contain the
49. NOTE The default settings indicated in the following table are the application defaults If a not the application defaults Table 4 3 DICOM Station Properties Import Tab Property Description Image compression Infinity LX can compress images as they are being stored The following algorithms are available e None the default The DICOM image is stored in Infinity LX with no modification e JPEG Lossless The DICOM image is compressed without loss This data compression is fully reversible and retains full image fidelity The transfer syntax is modified If the image is already lossless compressed RLE or JPEG Lossless or if the image is palette color then no compression is performed o i zd 2 i T gt o o D oO e JPEG Lossy The DICOM image is compressed with some loss of detail Use care when enabling this option The Q Factor specifies a trade off between image size and image quality Values range from 0 lowest quality highest compression to 100 highest quality lowest compression If the image is already lossy compressed or if the image is palette color then no compression is performed CAUTION JPEG Lossy images are not intended for diagnostic use e JPEG Lossy or Lossless if lossy impossible If the DICOM image has less than 13 bits per pixel stored then it is the same as JPEG Lossy The JPEG Lossy algorithm cannot be run on images with more than 12 bits per pixel If t
50. OM Store and Retrieve ceccccecseeeeeeeeeeeeeeeeeeeeeseeeeseeeeseaeees 5 3 Chapter 6 Managing Studies Study Manager Overview 6 1 Starting a Study Manager Session 6 2 Understanding the User Interface 6 4 Selection WiNndOW sssnareeann sure nn vie au 6 5 Datta SOURCES enina aom sienne sic rain asie nude Deez 6 6 Patient List and Study List Tabs 0 0 ececeseeeeeeeeeeeneeeeeneeteeteeeeee 6 6 Study Manager Desktop Tab ccceceeeeeeeeeeeeeeeneeesenaeeseneeeteneeeenees 6 8 Sorting Data in the Selection Window 6 8 Searching for Data iiscesseeccsshivvscdtecesece vedi detente tete Re NE a 6 9 Selecting Patients or Studies to View 6 12 Viewing IMAGES w csse ccceecseececeees detente riranna nE EN ANE EEE EE 6 16 Basic Toolbar Commands 6 17 MPR MODO arsi stereo cases ens O E 6 19 Dockable Toolbar Options 6 20 MIP MOde 22 283 aa eaaa E tenaient 6 23 Dockable Toolbar Options 6 24 Fusion MOde 2ssretener nmenenenennnnennen dr lend vrnainceevceseiinns 6 27 Notes About the Fusion Module 6 28 Display MOdeS esse uesenigeseinesuigienenninenun 6 29 Orthogonal Mode MR lente aia 6 29 Dual Orthogonal Mode cccccceeeeeeeeeeeeeeeeeeeteeeeeeeaeeteeeeeeeaeees 6 33 Triple Orthogonal Mode 6 34 Mosaic Only Mode 6 35 Advanced View
51. Report A report Record icons can also include status indicators These indicators are described in Table 6 3 Table 6 3 Record Icon Status Indicators Icon Description v The series is currently displayed T The series is partially displayed not all the images have been Be loaded D4 The series is not displayed the images have not been loaded D 5 D 5 e 2 o 2 O Codonics Infinity LX User s Manual 6 15 Viewing Images TS e From the Study Manager Studies List tab right click the record and select Display from the menu To view images e From the Desktop tab double click the record Or e Drag the record onto the workspace area in the Study Manager main window According to the display configuration and current settings one or more images in the study or series are displayed tl Study Manager File Edit View Tools Reporting Window wis m E OOFE ee ir eae Sad D TS User ADMIN Mem used 45 4M free 17 NUM Image viewing functions are available using the menus and toolbar in the Study Manager window Viewing functions include adjusting the lookup table LUT adjusting the image window level color table mapping resizing displaying of patient annotation and more 6 16 Managing Studies Basic Toolbar Commands Table 6 4 Basic Toolbar Commands Icon Description New Clear Selection aren Close all open series and return t
52. aced has one failed drive immediately If a hot spare drive is installed Infinity LX will The failed drive s status light automatically use this drive and turns red an audible alarm enter Rebuild mode sounds the System Status user interface status indicators are For complete replacement updated an email is sent tothe instructions refer to Replacing a administrator and an RSS article Hard Drive on page 7 2 is posted Rebuild A new drive has been installed to No user action is required replace a failed drive The system is rebuilding information on the new drive This takes approximately 8 hours for a 1 TB drive The system is still vulnerable to another drive failure during the rebuild Failed The RAID 1 or RAID 5 set has Contact Codonics Technical two or more failed drives All data Support for assistance on the RAID drive set is lost oO 3 ao D 2 a e e 2 e i T A no Codonics Infinity LX User s Manual 2 6 Hot Swap A hot swap is a replacement of a hardware component such as a hard drive fan or power supply module that can be performed while the system is operating Hot swappable components are usually part of a fault tolerant sub system such as a RAID array The components are designed to be safely removed and replaced to minimize system downtime Hot swappable hard drives are usually mounted in special carriers that allow them to be easily slid into the chassis and
53. al System ao Infinity LX startup fails Infinity LX does not have power Check the power cables Check the 4 5 power supply switches on the rear g A panel os The SmartDrive has been removed oS Verify that the SmartDrive is connected 3 The network is not The network settings are not configured Check the Infinity LX IP address and 2 responding properly the other network settings The network cable is not connected Verify that the network cable is connected to Ethernet port 2 The SmartDrive has been removed Verify that the SmartDrive is connected Infinity LX is not Infinity LX does not have power Check the power cables Check the responding power supply switches on the rear panel Cycle power to Infinity LX A DICOM station cannot The network settings are not configured Check all IP addresses and other connect with Infinity LX properly network settings Ping Infinity LX from the DICOM station The DICOM station is not properly Check the AE Title and DICOM port in configured on Infinity LX the Administration tool The network cable is not connected Verify that the network cable is connected to Ethernet port 2 The SmartDrive has been removed Verify that the SmartDrive is connected Infinity LX is not receiving A failed hard drive or failed power Contact Codonics Technical Support requests to store or supply has not been replaced within 24 1 440 243 1198 retrieve data hours or there is no more sto
54. all amounts of arsenic used in glass LEDs and semiconductors are not considered to be bioavailable 5 e 3 2 e e Bioavailable crystalline silica small amounts of crystalline silica are used in certain paints coatings and filler materials Polychlorinated biphenyls PCBs jelayeyy Snopuezepy e Asbestos e Organic tin not used in tin lead solder applications e Ozone depleting substances such as chlorofluorocarbons methyl chloroform and carbon tetrachloride Codonics Infinity LX User s Manual A 1 A 2 Mat riaux de Construction L appareil Infinity LX est conforme la norme RoHS et par cons quent ne contient aucun des composants suivants Afin d obtenir les certificats de conformit de ses produits dans le monde entier Codonics utilise les standards d valuation les plus contraignants pour tester ses produits Codonics assure notamment n avoir ajout ou avoir t inform que soit ajout les composants suivants dans son produit et son emballage Arsenic de tr s faible quantit d ars nic sont pr sents dans le verre les leds et les semi conducteurs sans port e atteinte a Vorganisme Cristaux de silicium Biphenyls polychlor s Amiante Mati res organiques Substances portant atteinte la couche d ozone tels que des carbones chlorofluor s du chloroforme et des t trachlorures de carbone Hazardous Material Information Manufacturing During manufactu
55. anual 4 27 Table 4 4 DICOM Station Properties Export Tab Continued Property Description Convert PET images to Contact Codonics Technical Support for assistance with CT images this or other advanced DICOM configurations CLogging Out Y gt On the Start menu click Log Off To log out of a After closing the current user session the Windows login screen Windows displays session Shutting Down and Rebooting There are three ways to shut down or reboot Infinity LX e From a Remote Desktop Connection e Locally from the optional monitor keyboard and mouse e Using the Power button at the front of the chassis The following topics describe each of these procedures Shutting Down or Rebooting from a Remote Desktop Connection or Locally Use the following procedure to shut down or reboot Infinity LX from a Remote Desktop Connection or from a monitor keyboard and mouse connected directly to Infinity LX 4 28 Setting Up the Software re 1 Before attempting to shut down or reboot the system make sure that all jobs have finished and all applications for example the To shut down Administration tool or Study Manager are closed or reboot the system from a 2 On the Start menu click System Shutdown Remote Desktop Connection or Admin locally papane one Administration 3 My Computer English iewer 777 Run Japanese Yiewer Windows Security System Status Remote Support s Gaa Click Syste
56. ark Office and in other countries Oracle is a registered trademark of Oracle Corporation and or its affiliates All other registered and unregistered trademarks are the property of their respective owners European Authorized Representative CEpartner4U Esdoornlaan 13 3951DB Maarn The Netherlands Tel 31 343 442 524 Contents Preface Conventions Used in This Manual ix Bulleted Lists nia aaa aiaa ria ix Numbered Steps 22 tack deeb aene Tec aient sein ix Notos and Tips ccena na nn et le ist x Cautions and Warnings Erai x Important Information and Filenames s es x Purposeand SCODe sites dessiceheceescssstccisceveseceveved eaaa OESEL aa EE aiaia xi Product Inf rmation ssstsidare exsavisessancdeh seencavezeeeine aobsiadesdertvevantdessinccdess xii Warnings and Limitations of Use xiii Safety and Compliance Labels cc ccceceeeeeeeeeeeeeteceeseneeeeeueeetsaeees xiii Voltage Warning scsi ewes serecc svete ad anaE AHN a AREENAN TA xiv Dangers lectriques sirius sniern asenne sedasa dainean an edora aoire iaat XV Laser Warning vesccess ccceecssasecsvetnecseteecesages seratna iane aitans re akene E Enni ienaa xvi Danger du Faisceau Laser xvi Serial Number Configuration Number Date Code and Modification Codes cccceeceeeeceeeeeeeeeeeeeeeeeaaeeseaeeeeaeeesseeeeenees xvii Potential for Radio Frequency Interference on Device Operation xviii Potential
57. assword Database Database ix 6 2 Managing Studies 3 Enter an Infinity LX user name and password then click the OK button The preconfigured logins provide different levels of access to the Study Manager admin which provides full access to all functions manager which provides access to view modify and delete studies in the database using the Study Manager tool operator which provides access to view and store studies in the database using the Study Manager tool After logging in Study Manager starts and the Selection window displays For information about how to end a Study Manager session refer to Exiting Study Manager on page 6 49 D 5 D 5 a no a Q D o Codonics Infinity LX User s Manual Understanding the User Interface You will see the following windows during a Study Manager session e Selection window Used to select a data source search for and select patients or studies and then browse through their related records Study Manager main window Used to view selected data and images using the window s menus and toolbar Study Manager main window Selection window a do i gt HE J Pa E 3 Selection File View Options CS Study ist EO Desktop E Patient Name Patient ID Study Date Study ID Accession Number From Sica Q Search in DEMACHEE IZA Patient ID Birthdate x Study Date Time
58. ata storage If more than one drive fails all data in that RAID set is lost The following diagram illustrates how the stripes G e parity blocks indicated by the data blocks of the same color are distributed across the RAID 5 drives RAID 5 Data Block 2c Data Block 3c Data Block 2a Data Block 3a Data Block 4p Data Block 4a Data Block 4b Data Block 4c Disk 0 Disk 1 Disk 2 Disk 3 Data Block 2b Data Block 3p Data Block 2p Data Block 3b Infinity LX uses RAID 5 to store DICOM study data The Infinity LX is available with two banks of RAID 5 drives in drive slots 1 through 5 and 6 through 10 Each bank of drives contains 5x1 TB drives and yields 4 TB of usable image storage remember that one drive is used for parity With both banks installed Infinity LX provides 8 TB of usable image storage When a RAID 5 drive fails the failed drive s status light turns red an audible alarm sounds the System Status user interface status indicators are updated an email is sent to the administrator and an RSS article is posted Terms and Concepts RAID Operating Modes Table 2 2 describes the four modes in which a set of RAID drives can operate Table 2 2 RAID Operating Modes Mode Description Action Required Optimal The RAID 1 or RAID 5 drive setis No user action is required operating normally All drives are good Critical The RAID 1 or RAID 5 drive set The failed drive must be repl
59. atus via RSS Infinity LX posts an article to its RSS feed when alert critical or fault conditions occur RSS feeds can be read using a web browser that includes an RSS reader extension or plug in Infinity LX also includes a desktop RSS reader Feedreader that displays a message box on the Infinity LX desktop when an alert critical or fault condition occurs Receiving Infinity LX RSS Feeds in a Web Browser Use the following URL to access the Infinity LX RSS feed from a web browser http infinity_ip_address status rss 8 12 Status Indicators and Troubleshooting Viewing RSS Status Information from Feedreader When an alert critical or fault condition occurs Feedreader displays a message on the Infinity LX Windows desktop Status Changed Codonics Infinity 10 1 90 165 Wed Sep 16 09 44 33 GMT 2009 Ready System is ready and has no problems to report Web Status Page To close the message and then display the Feedreader application to see details about the condition click anywhere inside the message box To close the message box click its Close button at the upper right corner of the box oo a8 os co os p O gt o CR 5 ome gt Q Using the Feedreader Application The Feedreader application is run automatically as part of the Infinity LX startup Typically it should always be left running so that conditions can be reported to the Windows desktop To open the Feedr
60. auto shutdown optional S Anti Virus Factory installed Codonics Infinity LX User s Manual B 1 B 2 Operating System Processor Memory Optical Drive Ethernet Interface Serial Interfaces Power Temperature Humidity Dimensions Weight Medical Compliance Electrical Safety Emissions and Immunity Specifications Windows XPe Intel Core 2 Duo processor 2 GB CD DVD 2 10 100 1000Base T Auto Sensing Ethernet RJ 45 2 USB 2 0 host side ports in front panel 1 USB port in front panel dedicated to the SmartDrive 6 USB 2 0 host side ports in rear panel 1 RS 232 serial port Universal Input 100 240 Vac 50 60 Hz 650 W Operating 15 30 C 59 86 F Storage 22 2 51 C 8 123 8 F Operating 20 80 noncondensing Storage 85 maximum noncondensing Height 16 9 in 42 9 cm Length 26 in 66 cm Width 8 7 in 22 1 cm Chassis shipped 81 Ibs 36 7 kg Hard drives shipped 28 Ibs 12 7 kg Chassis hard drives installed 92 Ibs 41 7 kg FDA Medical Device Class 1 manufactured in compliance with FDA GMP QSR 1 013485 2003 CE MDD 93 42 EEC compliance for Healthcare Facilities subject to installation guidelines Information Technology Equipment Safety Part 1 General Requirements UL 60950 1 Second Edition Dated March 27 2007 Information Technology Equipment Safety Part 1 General Requirements CAN CSA C22 2 No 60950 1
61. bered For example TS 1 Remove the SmartDrive from the chassis To configure 2 Connect the SmartDrive to a PC the system x 5 information 3 In Windows navigate to and run the Configurator exe file which is stored at the root level of the SmartDrive Codonics Infinity LX User s Manual ix gt Preface Notes and Tips Notes contain additional information related to a topic or procedure For example NOTE To shut down Infinity LX refer to Shutting Down and Rebooting on page 4 28 Tips provide additional insights about a topic or procedure such as why you may want to do something or a faster way to perform an operation For example TIP Basing a new DICOM station on an existing one To create new DICOM station entry that is based on one of the existing entries select the desired existing entry in the DICOM Stations dialog box and then click the OK button The new station s property settings in the DICOM Station s Properties dialog box will match the station entry that you selected Cautions and Warnings Cautions alert you to actions or situations that could cause harm to equipment or data For example CAUTION Adequate ventilation is required for proper operation of the Infinity LX Warnings alert you to actions or situations that could result in personal injury For example WARNING The two power cords connected to the uniterruptible power supply UPS or a wall outlet are the ma
62. by which Infinity LX will be identified on the network System Parameters Locale The language to use for Windows and the Infinity LX applications Purge Temporary Studies Select this option to have Infinity LX automatically remove studies marked as temporary Studies are purged when storage exceeds 95 Email Parameters To The email addresses that should receive the automated email status messages from Infinity LX Multiple email addresses can be set up by separating them with a semicolon and a space For example emaill sample com email2 sample com email3 sample com NOTE Specifying less than ten email addresses will provide faster notification Codonics Infinity LX User s Manual 3 21 Table 3 1 Configuration Parameters Parameter Description From The email sender name used in the automated emails that will be sent by Infinity LX SMTP Server The host name or IP address of the outgoing email server to be used by Infinity LX SMTP Username The username for Infinity LX to use for authentication by the SMTP server SMTP Password The password for Infinity LX to use for authentication by the SMTP server 3 22 Setting Up the Hardware Starting Up Infinity LX TS 1 If a monitor is installed press the monitor power button To start up Infinity LX o Power button lille 2 If there is a UPS power on the UPS 3 Turn on the power supply switches at the rear
63. cess for this utility to work When a connection is made Codonics Technical Support personnel can see the same screens as you and have the same control over Infinity LX as you do This allows you and Codonics to work cooperatively to solve problems You can disconnect the session at anytime If either Codonics or a user at the site disconnects only a user at the site can initiate a new connection For more information refer to the Codonics LogMeIn Feature Technical Brief Codonics Infinity LX User s Manual 8 21 oo ph 48 os co D 5 2 O gt o CR 5 0 Q o gt Q Qsystem Logs If your Infinity LX is experiencing problems Codonics Technical Support might ask you to access the system log files that are maintained by Infinity LX Technical Support might also ask you to send copies of the system log files to them This can be done by copying the log files to a CD DVD or USB flash drive and then copying them to and emailing them from another system or sending the disc by mail 8 22 Status Indicators and Troubleshooting A Hazardous Material Information Materials of Construction The Infinity LX unit is ROHS compliant Codonics has set very stringent standards for evaluating products to ensure the marketing of regulatory compliant products worldwide We do not intentionally add nor are we aware that the products or packaging contain the following materials e Bioavailable arsenic sm
64. ck is complete the hot spare drive is available again SATA and SATA II SATA Serial Advanced Technology Attachment is a standard for connecting individual hard drives inside a computer with a small flexible cable The original SATA standard supported interface speeds up to 1 5 Gigabits sec SATA II is an improved version that is faster up to 3 Gigabits sec SATA and SATA II drives have been adopted by every major PC manufacturer because they improve performance and are easier to connect than older IDE hard drives that use wide ribbon cables Infinity LX uses SATA II hard drives SAS SAS Serial Attached SCSI Small Computer System Interface is a standard for connecting many hard drives to a system A single SAS port provides transfer speeds up to 12 Gigabits sec and can control up to 256 SATA hard drives External SAS ports can be used to connect one or more storage expansion chassis each with multiple hard drives installed Infinity LX includes a SAS port on the rear panel for adding future expansion chassis for more storage A special locking SAS cable connects the main and expansion chassis together to prevent accidental disconnect Codonics Infinity LX User s Manual 3 77 D 2 a e e 2 e iv T A no RSS RSS Rich Site Summary is a format for delivering regularly changing web content Many news related sites weblogs and other online publishers syndicate their content as an RSS feed
65. correcte est n cessaire au bon fonctionnement de Ne pas poser d objets sur l appareil Ils risqueraient de bloquer la ventilation ou de fendre le capot Les Serveurs d images M dical Codonics Infinity LX sont fabriques et testes pour tre conforme a la certification et tre utilise dans un environnement administrative dans une structure bospitaliere D Infinity LX west pas con u ou certifier pour un contact direct patient ou tre utilis dans une limite de 1 83m du patient ou dans un environnement explosif ou des gaz inflammable comme en anesth sie ou de l oxyg ne peuvent tres pr sent WARNING Une mise la terre fiable est possible seulement pendant que Infinity LX ou son onduleur UPS s est connect aux appareils marqu Hospital Only de qualit hositali re d isolement ou un UPS m dical dans un environnement qui n cessite un courant de fuite de moins de 300 A Merci de v rifier les ordonnance sp cifiques locale r gionale et h pitaux afin de d terminer l application de n importe quel touts standard lie au placement et a l utilisation du produit Infinity LX WARNING L utilisateur doit consid rer l utilisation d un transformateur e Ne placez pas l appareil dans une zone propre et non bumide Des particules de poussi res peuvent causer des disfonctionnements vitez de placer l appareil proximit d une bouche de ventilation d une porte ou d un lieu tr s fr quent car c
66. ctronics CAUTION Use care when unpacking and handling hard drives You should be 3 10 Setting Up the Hardware 2 Match the number on the top of each hard drive to the number on the slot n 2 le i T gt D IT D a o p amp coocoo Codonics Infinity LX User s Manual 3 11 3 Open the hard drive lever by pulling down on the blue tab to about 45 AT 7N 4 Insert the hard drive fully into its slot in the chassis soe WOO 29 _ slot Push the drive as far into the slot as it will go it should be flush with the neighboring drives There is some resistance as the back of the drive is seated in the cage and it is possible to latch the lever without having the drive fully installed It is critical that all drives are properly installed prior to the initial system startup CAUTION When installing the hard drive it is important to install it all the way into its 3 12 Setting Up the Hardware Setting Up the Hardware Sos E A WE 5 Close the hard drive lever 3 13 Codonics Infinity LX User s Manual 3 14 Installing the UPS Acce
67. d Drive on page 7 2 CAUTION Do not remove any other hard drives or shut down Infinity LX until the hot spare drive has been replaced or reinstalled Replace or reinstall the hard drive refer to Replacing a Hard Drive on page 7 2 CAUTION Do not remove any other hard drives or shut down Infinity LX until the hard drive has been replaced or reinstalled Replace or reinstall the other hard drive refer to Replacing a Hard Drive on page 7 2 Wait for the rebuild Automatic Copyback operation to complete on that hard drive before replacing or reinstalling the second failed hard drive CAUTION Do not send studies remove any other hard drives or shut down Infinity LX until the hard drive has been replaced or reinstalled Codonics Infinity LX User s Manual oo ph 48 os co D 5 p O gt o CR 5 Q o gt Q Table 8 5 Troubleshooting Continued Problem Possible Causes Solutions A hard drive in an array is The drive has either failed or is not Install a hard drive in slot 13 refer to in a fault state andthe hot installed and the hot spare drive has Replacing a Hard Drive on page 7 2 spare drive is not been removed wait for the rebuild operation to installed complete then replace or reinstall the hard drive in the array CAUTION Do not remove any other hard drives or shut down Infinity LX until the hard drive in the array has been replaced or reinstalled A
68. d temporary or permanent storage of images Infinity LX provides a comprehensive set of system notifications and warnings using web email RSS and visual audible alerts built into the system Codonics Infinity LX User s Manual 1 3 5 e a c O peg fe 1 4 Introduction Features and Benefits Infinity LX provides the following features and benefits Compact all in one design provides an affordable solution for DICOM image storage High performance architecture for fast DICOM file transfers Optimized for large DICOM data sets including DICOM files over 2 GB Highly redundant hardware design including RAID power supplies and cooling fans Simple system setup with preconfigured settings for non technical personnel Optional JPEG Lossless image compression increases storage capacity up to 2 5x Configurable access control with audit trails to assist with patient confidentiality compliance System Status tool provides a web based user friendly interface for remote monitoring of the Infinity LX operating status Terms and Concepts This chapter explains important terms and concepts that users need to understand when using Infinity LX Terabyte 1 TB 1 trillion bytes 1 000 gigabytes GB Note that there is a difference between the total storage capacity of a hard drive and the usable capacity after the drive has been initialized for use in a RAID If a system uses 5 1 TB hard drives i
69. e password so that it matches the password that you set for that user in the Administration tool Codonics Infinity LX User s Manual 4 11 QSetting the Date and Time Use the Date and Time function in the Windows Control Panel to set the date and time for the system Accessing the Infinity LX RSS Feed The Infinity LX RSS feed can be accessed using a web based or desktop RSS reader also called a feed reader Use the following URL to access the Infinity LX RSS feed http infinity_ip_address status rss where for example the Infinity LX IP address is 10 1 44 100 If the IP address is unknown check the Configurator to see the IP address setting Infinity LX includes a desktop RSS reader Feedreader that displays a message box on the Infinity LX desktop when an alert critical or fault condition occurs For more information about using Feedreader refer to Viewing RSS Status Information from Feedreader on page 8 13 4 12 Setting Up the Software G Aliowing DICOM Station Access Each DICOM station that requires store or retrieve access to studies on Infinity LX must be defined on Infinity LX using the Administration tool Typical DICOM stations that would connect to Infinity LX include e Modality workstations e PACS workstations a e Primary and secondary image acquisition systems a T ic 1 Locate the Administration tool icon on the Infinity LX desktop 3 o To allow Administration to
70. eader application click its icon in the Windows taskbar tray Click the Feedreader icon Codonics Infinity LX User s Manual 8 13 8 14 The Feedreader window displays the most recent condition and includes a list of previous condition messages rs Status Feed Monitor Woe Program Feeds Subscriptions Language Codonics Infinity 10 1 90 165 Wed 16 Sep 2009 09 44 33 GMT Ready Tue 15 Sep 2009 18 25 05 GMT Building RAID A3 09 16 2009 00 00 00 Wed 16 Sep 2009 09 44 33 GMT Ready Ready System is ready and has no problems to report feghttp 10 1 90 165 status monitor Feeds refreshed Feed s 0 item s and 0 error s verified To open the System Status user interface click its link To open the System Status user interface from the Feedreader window to view detailed status information about the most recently reported condition click the link shown above e To minimize Feedreader back to the Windows taskbar tray click the window s Close button at the upper right Feedreader will continue to report on status conditions e To exit Feedreader open the File menu and click Exit Feedreader closes and will no longer report on status conditions Status Indicators and Troubleshooting froubleshooting Common Problems The following table lists common problems their possible causes and how to solve them Table 8 5 Troubleshooting Problem Possible Causes Solutions Gener
71. ecting the Fusion icon in the main application the Viewer application automatically browses the loaded series If it does not find suitable series the Series Selection dialog box displays Otherwise the Fusion protocol starts with the loaded series Fusion x Functional image A Select el Anatomical image A Select E m Secondary functional image Optional A Secondary anatomical image Optional ie P Cancel In the Series Selection dialog box there are two ways of selecting the input images for Fusion e By activating the requested image in the general display then pressing the corresponding Select button on the selection dialog box e By navigating through the patient study series in the menu tree that pops up by clicking the corresponding _ button Using one of those methods select a functional image and repeat the operation for the anatomical image if needed A second functional image can be selected for use in the dual orthogonal mode it can be selected later when switching to dual ortho mode To clear the selection click the corresponding ib button cCodonics Infinity LX User s Manual 6 27 D 5 D 5 a no a 2 D o Notes About the Fusion Module e The Fusion module works only with images for which the image orientation and image position data has been coded by the modality e All the images of the input series must have the same slice
72. ela pourrait exposer l appareil ainsi que les m dias a la poussi re e Ne placez pas l appareil proximit d une source de chaleur ou de substances acides Codonics Infinity LX User s Manual xxiii xxiv Preface Ne placez pas l appareil dans une pi ce o il y a des vapeurs buileuses et grasses Nexposez pas l appareil la lumi re directe du soleil Ne placez pas l appareil pr s des sources d nergie RF des champs bauts magnetiques ou du rayonnement ionisant Cleaning Precautions e Plastic components are used in the device s construction Coat flecking and deformation are likely to occur if the device is wiped with chemical dusters benzene thinners insecticides or other solvents Rubber and PVC materials left in contact with the device for extended times will cause damage Never use petroleum based solutions or abrasive cleaners To clean the chassis enclosure first disconnect overall power to Infinity LX shut down the system refer to Shutting Down and Rebooting on page 4 28 and then power down the device refer to Removing Power to Infinity LX on page 4 32 Clean the enclosure with a soft cloth slightly moistened with a mild soap and water solution Allow the enclosure to completely dry before operating the device again Pr cautions d Entretien Cet appareil comporte plusieurs pi ces en plastique Des taches et des d formations peuvent tre provoqu es par l utilisati
73. ent kilograms All these values ought to be imported from the original CTI and the pixel data counts have to be in Bq ml If one is missing the SUV will not be proposed to the user The injected dose is decay corrected to correspond to the existing dose at the time the image is acquired tl m20 DI Dee Then SUV values are obtained using the formula 1000 V tse W SU counts e Di Codonics Infinity LX User s Manual 6 39 D 5 D 5 a no a Q D o 6 40 IF To view a record s information iewing Editing Record Information From the Study Manager Studies List tab or Desktop tab right click the record patient study series image or report whose information you want to view then click Properties in the pop up menu An Information dialog box displays for the record you selected A sample Study Information dialog box is shown below G gt Study Information Database Identification Keywords History Study Accession Number 7405173020981966 Study ID 7405173020981965 Description SPLEEN Study Date J2080 12 10 M Study Time 13 03 16 2 Study Status ID STARTED iv Patient Family Name Doe First Name John Patient ID 7405173020981 967 Weight 0 kg iv Height om iv Requesting Physician Service Managing Studies You can access patient information by clicking the Edit button in the Study Information dialog box which ope
74. ering a fault condition A fault condition occurs when Infinity LX requires immediate attention due to hardware failure and or cannot process storage and retrieval requests The specific critical or fault condition is displayed in the Dashboard status message area and in the information panel area 8 8 Status Indicators and Troubleshooting Navigating Detailed Status Information To view detailed status information click on an entry in the navigation tree on one of the status icons in the Dashboard or in an information panel Click a navigation Click a tree entry status icon a eae REESE fes 0 10190165 100 0 13Drives 54 0 C A Click in an information panel The following sample screen shows the Chassis information selected Chassis status information selected and displayed in the information panels A COIDONICS N ak E F P gt gt Wed Sep 16 0 ila fini buy 10 1 90 165 100 0 13Drives 53 0 C SL LLLLLLES 4 Temperature amp Main Chassis Drives Legend cCodonics Infinity LX User s Manual oo a8 os co os p O gt o CR 5 ome gt Q Detailed Status in Information Panels Detailed information is displayed in the information panels System 10 1 137 32 Storage Network System UPS Main Chassis Drives Temperature ir amp 95 10 1 137 32 100 Temperature CPU Temperature 50 0 C CPU Fan Speed 0 RPM Wed Oct 22 17 53 EDT CPU Fan
75. fault password for the preconfigured user accounts is codonics password for these user accounts the first time you log in For more information refer CAUTION To prevent unauthorized access to the application you should change the to Changing a User s Password on page 4 8 Codonics Infinity LX User s Manua 4 7 doni fini Changing a User s Password Y gt 1 Locate the Administration tool icon on the Infinity LX desktop To change a Administration tool user s Icon password Sar Do 5 23PM 2 Open the Administration tool 3 At the login enter the administrator user name admin Connection x User ADMIN Password Database Infinity Cancel ya NOTE Entries in the User field are converted to uppercase automatically D 4 Enter the administrator password the default is codonics 4 8 Setting Up the Software 5 Click the OK button The Administration tool displays 6 Click Users The Users configuration window displays Click Users Administration Users 3G Eile view Action Help 2x List of Users Add Copy Configuration From Edit SQ MANAGER j Q OPERATOR Wests Associated Role MAN Associated Services Code Name There are no items to show in this view Control Ready User ADMIN NUM A Codonics Infinity LX User s Manual 4 9 wn 2 2 i T gt
76. for Radio and Television Interference xviii Safety Precautions c ccccccecceeeeeeeeeceeeeeeeneeeeeeaeeseaeeeseaaeeseaeeeseeeeteeees xix Pr caution d Emploi sus XX Location Pr cautions sean ai a ea ata Na a ia nS a xxi Environnement de Fonctionnement xxii Cleaning Precautions xxiv Pr cautions d Entretien ss XXiV Maintenance Precaution c cceccecceeeeeeeeeeeeeeecnaaeeeeeeeeeeeseeeenenaees XXV Pr caution d Entreten sessin ss XXV Image Formats Supported cecceceeeeeeeeeneeeeneeeteaeeeseeeeseeeeteneeeeeeaees XXV Formats d Image Accept s ccccceeceeeeceeeeeeeeeeeeeeeeeeaeeeeeeeeseeeeeeeeees XXV Codonics Infinity LX User s Manual Contents Medical and Patient Information XXV Disposal Requirements cceececeeeeeeneeeeeeseneeeeeeeeneeeeeeeenaeeeeeeenaeeeeeeeaaes xxvi Conditions et R gles d Utilisation xxvi European Disposal Requirements cccccceeeeseeeeeeeenneeeeeeeneeeeeeeaes xxvi Indications for Use xxvii Chapter 1 Introduction Welcome and Congratulations cceceeeeeeeeeeeeeneeeseeeeseeeeeeeeeseeeeteeees 1 1 Product FE ATUNES rss ses dieu ncdueveueewadveneudnededenetescunertoemedey 1 2 Ease of Setup and Use eececcecececeeneeeeaeeseeaeeseaeeeeeseeeseeeeeesaeeessnees 1 3 Features and Benefits cccccccccccccsecsseeeseeeseeeseesseeseeeseseee
77. his is the case the format is switched to JPEG Lossless Codonics Infinity LX User s Manual 4 23 Table 4 3 DICOM Station Properties Import Tab Continued Property Description Matching Use the Patient and Study lists to specify the data fields that will be examined to determine if the study being stored matches a study already in the Infinity DICOM Server s database Recommended By default PID Lastname is selected in the Patient list and Study Instance UID is selected in the Study list There are other options in the Patient list Accession Number Date of Birth and Patient Full Name Storage Commitment Select this option to specify a timeout for storage commitment If all the instances listed in a storage commitment request are not stored before the timeout started upon reception of storage commitment N ACTION Infinity LX returns a storage commitment response with a failure status By default this option is not selected DICOM VR format Some modalities do not correctly format PN Person Name and DA Date value representations These two fields allow modifying the parsing of these VR to correctly decode them even if they do not follow the DICOM standard Most modalities conform to the DICOM standard and these two parameters should not need to be modified 4 24 Setting Up the Software Table 4 3 DICOM Station Properties Import Tab Continued Property Description Study Completed Inf
78. ic Mode Split the current display window so that HF multiple series may be displayed Cine Loop z p Allows display of multiple images from a PVO series one after the other Clicking on the forward or reverse buttons allows the increase or decrease of the display rate Left Mouse controls ay The default action for the left mouse button Window Level adjusts the window level of the active image Left Mouse controls Tr Allows movement of the active image within Image Position JF the display window Left Mouse controls Zoom Level Ps Allows for zooming in and out Left Mouse controls Move through the images of the selected Stack Navigation Vs series Left Mouse controls Move the series to another display section Drag and Drop A used in Mosaic Mode 6 18 Managing Studies MPR Mode D Y gt Click the a button Then click on the MPR tab to activate the MPR mode To enable MPR mode The MPR screen features a dockable toolbar an orthogonal viewer and a reconstructed series display The orthogonal viewer shows the input image along three orthogonal views In addition it also shows the MPR cut plane intersection blue line the current frame displayed on the reconstructed series solid red line and the reconstructed volume limits red dotted lines The reconstructed series view behaves like the regular mosaic views in the general display It shows the reconstructed series along the direction of the blue line
79. ics Infinity LX User s Manual 4 31 Removing Power to Infinity LX CAUTION Improperly removing power to Infinity LX could cause data loss TS 1 Shut down the system as described in Shutting Down and Rebooting on page 4 28 To remove power to 2 Turn the Infinity LX power supply switches at the rear of the chassis to Off Infinity LX Power supply switches 3 If the system includes a UPS turn the UPS power supply switch to Off 4 Disconnect the two Infinity LX power cords from the UPS or the wall outlet 4 32 Setting Up the Software G infinity LX SmartDrive The SmartDrive allows a device s configuration to be moved to another device This feature is especially helpful when swapping devices for service purposes CAUTION If the SmartDrive is not inserted Infinity LX can start up but configuration AN settings such as email addresses locale and a static IP address if used will not be available Also no temporary studies will be removed from the system until the SmartDrive is replaced and Infinity LX is rebooted Note that a SmartDrive cannot be duplicated That is it cannot be used in two devices at the same time The SmartDrive stores the following information n i 2 i T gt o wn D oO e Software license code This is the license code for the Infinity LX software This code is also p
80. ify the software except as described in configuration tasks documented in this manual The chapter also includes e Logging in and logging out of a Windows user session on Infinity LX e Shutting down and rebooting the system software e A description of the SmartDrive Codonics Infinity LX User s Manual 4 1 QLogging In Logins can be performed from remote PCs using the Remote Desktop Connection application Logins can also be performed from a local monitor keyboard and mouse if the Infinity LX configuration includes them Logging In Using Remote Desktop Connection Infinity LX includes support for Remote Desktop Connection allowing remote access to a Windows session on Infinity LX ya NOTE Infinity LX supports only one Remote Desktop Connection at a time D TS 1 From a PC on the network or a PC connected to Infinity LX ee using an Ethernet crossover cable start the Windows Remote To log in using Remote Desktop Connection application open the Start menu and Desktop select All Programs gt Accessories gt Communications gt Connection Remote Desktop Connection from a remote PC The main Remote Desktop Connection dialog box displays Remote Desktop Connection Computer Connect _ Cancel at Help Options gt gt ya NOTE If the PC does not have the Remote Desktop Connection application download the application from the Microsoft Windows website 2 Click the Options
81. ight be red for about a minute This is because it takes some time for the RAID controller to recognize the new drive The RAID controller will begin to rebuild the new hard drive with the data from the hot spare drive Infinity LX is fully functional during this process which takes approximately 8 hours Codonics Infinity LX User s Manual 7 7 2 3 5 D 5 O o 7 8 The System Status tool will show the progress of the rebuild operation v v Se A r ul 95 10 1 137 32 100 E System 10 1 137 32 Storage Network System UPS Main Chassis Drives Temperature Drives Legend Ready gt Rebuilding Failed Missing Empty A A 12 Drives If the system is in the middle of rebuilding with the hot spare drive that process will finish even if you replace the failed drive Once that is complete and the failed drive has been replaced the Automatic Copyback to the replacement drive will start that process takes approximately 4 hours Maintenance L L IS To replace a power supply module Replacing a Power Supply Module Infinity LX features two hot swappable power supply modules If one module fails Infinity LX will continue to function normally for 24 hours After 24 hours without replacement of the failed power supply module DICOM services will shut down as a safety precaution The system will beep and the System Status user interface will provide a message to indicate
82. in disconnect for Infinity LX Important Information and Filenames Bold type is used for emphasis command names and paths or filenames For example e When you have completed entering the system configuration parameters click the Save button and close the window In Windows navigate to and run the Configurator exe file which is stored at the root level of the SmartDrive Purpose and Scope Refer to this user manual for procedures on how to perform the Infinity LX user operations including Setting up the hardware and software Performing system administration functions Sending studies from DICOM stations Retrieving studies to DICOM stations Managing stored studies Maintaining Infinity LX Monitoring system status and troubleshooting common problems Codonics Infinity LX User s Manual xi Product Information Preface For technical assistance with Infinity LX call the Codonics Technical Support System at the following number Phone 1 440 243 1198 Toll Free 800 444 1198 USA only The Customer Service System is available weekdays from 8 30 AM to 5 30 PM EST U S holidays excluded Technical Support is also available online via email and the Codonics web site Email support codonics com Web Site www codonics com General product information can also be requested by sending email to Email info codonics com Please include your postal mailing address and telephone number in the email me
83. information stored on SmartDrive 4 33 disposal requirements xxvi features 1 2 to 1 4 hard drives replacing 7 2 hazardous material information A 1 to A 3 indications for use xxvii installing 3 7 to 3 18 installing software 7 23 laser warnings xvi location precautions xxi location finding 3 1 maintenance 7 1 to 7 24 maintenance precautions xxv power supply modules replacing 7 9 radio and television interference xviii radio frequency interference xviii reboot from local monitor 4 28 reboot from Remote Desktop Connection 4 28 reboot using chassis power button 4 30 remote Technical Support access 8 21 removing power to 4 32 RSS feed 4 12 safety and compliance label locations xiii safety precautions xix to xxi serial number label xvii shipment 7 24 shutdown from local monitor 4 28 shutdown from Remote Desktop Connection 4 28 shutdown using chassis power button 4 30 specifications B 1 to B 4 starting up 3 23 status information receiving via email 8 12 status information receiving via Feedreader 8 13 status information receiving via RSS 8 12 status information receiving via web browser 8 12 status information viewing 8 4 storage capacity 2 1 study data backing up 7 1 swapping for service reasons 4 33 troubleshooting 8 15 to 8 20 unpacked components 3 2 voltage warning xiv Infinity LX database 6 1 6 2 6 9 Information dialog box 6 40 install
84. ing Considerations 6 36 SUV Calculations 242222 AE es 6 39 Viewing Editing Record Information ccccceeeeeeeeeeeeeeeeeeeeneeeteneeeteaes 6 40 Exporting Records erei a EENE 6 42 Configuring a DICOM Destination Server 6 42 Exporting a Record esarri ER O 6 46 D l ting Records 8eme ra R REEERE 6 48 Exiting Study Manager ccccceeeeeeeeeeeeeeeeeeeeseeeeeeeeetecaeeseeeeeeeaaeeteaeeee 6 49 Chapter 7 Maintenance Backing Up Study Data 00 cccccececceeteeeeeeeeeeeeeeeeaeeeeeaeesecaeeseeaeeseaeeeeeneeeeees 7 1 Cleaning the Chassis Enclosure 7 1 Replacement Procedures 7 2 Replacing a Hard Drive su 7 2 Replacing a Power Supply Module ecceceeeeeeeeeeeeeseaeeeteneeeeeaeees 7 9 Replacing the Chassis ccccccseeceseeeseeeeeeeneeeseeeeseseeeseeeeeseneeenaaes 7 12 Ordering PAINS 22888 annee dns 7 22 Installing Infinity LX Software ccceccececeeeeeeceeeeeeeeeeeseeeeseeeeeeneeeessaeeeeaes 7 23 Preparing Infinity LX for Shipping 7 24 Chapter 8 Status Indicators and Troubleshooting Audible Status Alarm si 8 2 Front Panel Status Lights siisii siiin a aa oea aiaia 8 3 System Status User Interface 8 4 Status Indicators 2 2 cece eee eeceee ee eece ee eeee ee eeeeeeeaeeeeeaeeeseaeeeseaaeesenaeeesaes 8 6 Navigating Detailed Sta
85. inity LX is able to determine when all images in a study have been received from the sending DICOM station and the study is completed When a study is complete thumbnail JPEG images are generated for users with a web viewer The following methods can be selected to define when a study is completed e Not Automatically the default Infinity LX will leave the study in an open state To mark a study as complete and have JPEGs generated manually mark the study as Completed in the Study Manager right click on the specific study and in the pop up menu select Status and then select Completed e After a timeout The time out is started upon reception of the first image in the study Recommended for generating thumbnail JPEG images 30 seconds n i 2 i T gt o wn D oO e When the association is closed This method can be used when the DICOM station sends all of the images for a study in one DICOM association e Using storage commitment This method can be used only when the DICOM station uses storage commitment Study Started If the study being stored already exists in the Infinity DICOM Server s database the Procedure Description Study Date Time and Study ID can be updated with the incoming study s DICOM information depending on these settings The default for all three settings is Never Dictionary The storage process uses a dictionary to decode DICOM tags and insert them in the databa
86. ions configuration Search criteria E DICOM Destination Add Doc 4 Click the Add button 6 42 Managing Studies Another DICOM Configuration dialog box displays for configuring a DICOM destination server DICOM configuration General Advanced Server Name AEtitle DESTINATION_AE Port number 104 Hostname 10 1 136 154 Connection Network v Client Name AEtitle DxDCMserver Port number 104 Remote server optional Name AEtitle DICOM communication O Get Move Remote move Configuration name DICOM Destination 5 Configure the parameters on the General tab refer to Table 6 4 for a description of the parameters Table 6 5 DICOM Destination Server Parameters General Tab Property Description Server Settings Name AE Title Enter the Called AE Title of the destination server e g DESTINATION AE Hostname Enter the IP address of the destination server Port number Enter 104 Client Settings Name AE Title Enter DxDCMserver as the Calling AE Title for Infinity Remote server Name Not used AE Title o 2 o 2 le no E oO 77 Codonics Infinity LX User s Manual 6 43 6 44 A Table 6 5 DICOM Destination Server Parameters General Tab Property Description DICOM communication Select the Move option Configuration name Enter a name for the DICOM destination server This
87. isconnect overall power to Infinity LX prior to servicing it shut down the system refer to Shutting Down and Rebooting on page 4 28 and then power down the device refer to Removing Power to Infinity LX on page 4 32 Codonics Infinity LX User s Manual 3 15 n f 2 le i T gt D IT D a o p 4 Connect the serial cable supplied with the UPS to the UPS and to the serial port on the chassis rear QB OBO oO re O ORORO OD a 0052605001 OP D J 0250808282 Bd 0RO8EZe8o8a ODOLORO sea OSORO ROS BORD O DO 2020 0000000000 H Setting Up the Hardware 3 16 For the UPS model outside of North America connect the UPS AC power cord to the power connector on the UPS rear panel Connect the UPS power cord to a power outlet Codonics Infinity LX User s Manual ty 3 17 n le i T gt D IT D a o p 3 18 Monitor Keyboard and Mouse Optional TS 1 Connect the keyboard and mouse to USB ports on the chassis connector panel To connect a monitor keyboard and mouse 2 Connect the VGA cable betwee
88. ise no preference is defined and Infinity LX will determine the appropriate transfer syntax If this option is selected the transfer syntax choices are Choices are e Keep Original Transfer Syntax the default If selected Infinity LX tries to send DICOM files with no transfer syntax conversion e No Compression Transfer Syntax If selected all DICOM files with compressed transfer syntax lossless or lossy are converted to Explicit or Implicit Little Endian o i zd 2 i T gt o o D oO e JPEG Lossless If selected all uncompressed DICOM files are converted to JPEG Lossless e JPEG Lossy If selected all non lossy images with the Bits Stored field set less than or equal to 12 are compressed with JPEG Lossy CAUTION JPEG Lossy images are not intended for diagnostic use e JPEG Lossy or Lossless if lossy impossible If selected the operation is the same as JPEG Lossy unless lossy is impossible in which case JPEG Lossless is used Use Storage Select this option to have Infinity LX send a storage Commitment commitment request when storing instances to the DICOM station If the storage commitment response is not received before an optionally specified timeout has expired the store is set to failed By default this option is not selected Dictionary Contact Codonics Technical Support for assistance with this or other advanced DICOM configurations Codonics Infinity LX User s M
89. king materials contact your Codonics representative for instructions on how to return it Status Indicators and Troubleshooting CAUTION Infinity LX includes several redundant systems and a robust user warning system to decrease the likelihood of permanent data loss It is imperative that users act to prevent permanent data loss when Infinity LX indicates that there is a problem Failure to do so may invalidate the system warranty and will jeopardize system data oo a8 os co os p O gt o CR 5 Q o gt Q Codonics Infinity LX User s Manual 8 1 8 2 udible Status Alarm When Infinity LX detects an alert critical or fault condition it sounds a continuous audible beep as a status alarm If this occurs you should check the other status indicators described in this chapter to determine what is causing the condition Infinity LX also sounds six beeps upon a successful startup To turn off the audible alarm press and momentarily hold the Mute button on the front panel Mute button ya NOTE After pressing the Mute button it might take up to ten seconds for the audible alarm to stop L NOTE Pressing the Mute button mutes only the current alarm It does not mute future alarms Status Indicators and Troubleshooting Front Panel Status Lights LED status lights are located on the chassis front panel o LE Power O Hard drive power Not used Hard d
90. lable from the U S Government Printing Office Washington D C 20402 Stock No 004 000 00345 4 This product is in conformity with the protection requirements of EC Council directive 89 336 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility This product satisfies the Class B limits of EN55022 A declaration of conformity with the requirements of the Directive has been signed by the Director of Quality Assurance and Regulatory Affairs This product is in conformity with the requirements of EC Council directive 93 42 EEC on the approximation of the laws of the Member States relating to medical devices This product satisfies the Class B limits of EN 55022 and CISPR 22 Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Classe B prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada Safety Precautions e Never connect Infinity LX to any outlet or power supply that has a voltage or frequency different than that specified 100 240 VAC 50 60 Hz e Use only the power supplies provided with Infinity LX Codonics part number SP 00437 e When replacing power supplies or the chassis always disconnect overall power to Infinity LX prior to servicing it shut down the system refer to Shutting Down and Rebooting on page 4 28 a
91. le 4 2 DICOM Station Properties Grant Tab Property Description Supports Other Objects Selecting this option indicates that Infinity LX will support the following operations for non image DICOM objects e Accept the objects e Export the objects to a destination e Allow a DICOM host to Query Retrieve an object that resides on Infinity LX DICOM Station Properties Import Tab The Import tab is used to configure how images are stored to Infinity LX using DICOM Store Table 4 3 describes the station properties that can be set on the Import tab shown below DICOM Station s properties X Identification Grant Import Export Image compression Study completed ME p Eaei telia cenges oent fo 100 High quality low compression Not automatically 4 Matching Study started When importing the first image in the study some study s attributes in database can be updated from the DICOM file Patient PID Lastname Study Study Instance UID lais Procedure Description Never Zi Storage Commitment Study Date Time Never Bi I Time out min Study ID Never Rd DICOM VR Format Patient Name PN FAM XFIR MID PRE SUF Date DA YYYYMMDD Dictionary lt default gt 4 22 Setting Up the Software profile has been copied from an existing one the settings will match the source profile and ya
92. m Shutdown System Shutdown All Programs gt Log Off g Disconnect You are prompted to confirm the shutdown 3 Click the Shutdown or Reboot button System Shutdown 2 j amp re you sure that you want to shut down Shutdown 4 Click Shutdown or Reboot cCodonics Infinity LX User s Manual 4 29 n 2 i T gt D wn D p The Power light at the front of the chassis turns off when shutdown is complete Power light E E de O O HHH Jo oo Shutting Down Using the Chassis Power Button TS 1 Before attempting to shut down the system make sure that all jobs have finished all applications are closed and no user is To shut down ieee f logged in via the Remote Desktop Connection using the chassis power button 2 Momentarily press the Infinity LX Power button at the front of the chassis H HURE Power button 7 Oo Q jo o o 4 30 Setting Up the Software The chassis Power light turns off when shutdown is complete D Power light E ee O O gt a Ta m ANAM TAAAAE LANAN TARA n i 2 i T gt o wn D p Codon
93. manually open the import export status dialog box click the icon in the Windows taskbar tray 54 4 14PM Click the Study Manager import export activity icon The status dialog box displays The yellow indicator shown below indicates that the transfer is still running Dx ImpExp Spooler Job View Help D Level Source Destination Status Patient Name Patient ID Cooot Database DICOM Destination Running Doe John 740517302 When the transfer completes the import export status dialog box automatically opens to show the transfer status a green indicator if successful and a red indicator if unsuccessful D 5 D 5 a no a Q o Codonics Infinity LX User s Manua 6 47 doni fini 6 48 Deleting Records To manage storage space you can delete selected records or delete all records at or above the selected records for example delete the study in which the selected image is contained YS 1 To delete a selected 2 record TS 1 To delete records and 2 their parent records From the Study Manager Desktop tab click to select the record patient study series image or report to be deleted Press the Delete key You are prompted to confirm the deletion Click Yes The record and its sub records are deleted For example deleting a study also deletes all of its series From the Study Manager Desktop tab Ctrl click to select the records patient
94. min and max on the active view e Select the SUV Scale option to display a color bar coded in SUV values on each functional view Measurements The following measurement buttons are at the bottom of the toolbar e Distance measure the distance on a straight line Free hand compute statistics on a free form region of interest after drawing the region double click to close the region and display the statistics e Ellipse compute statistics on an elliptical region of interest These features are available only on mosaic views not on orthogonal or MIP views Managing Studies Dual Orthogonal Mode Display mode Dual ortho w HES Y 5 704 SUV 21 Anatom 2 5 704 SUV F lef Funct Window levels I SUV Scale Mosaic view VW Ww Func Anat Fus a 2 Slice thick mm JF 3 044 SUV P T 3 044 SUI 3 044 SUV The Dual Orthogonal mode features two orthogonal views for synchronized display of two functional images registered over the same anatomical image or two sets of functional and anatomical images The cross target position is not synchronized on both views they both work independently The two studies can be switched by pressing the MA button This is especially useful since only the top study can be displayed in other modes such as mosaic or triple orthogonal D 5 D 5 e 2 o 2 O Codonics Infinity LX User s Manual 6 33 Triple Orthog
95. n Storage Commitment Select this option the default to allow the DICOM station o granted to send a storage commitment N ACTION 2 2 MPPS granted This option is not currently supported It should be selected by default v gt Only key images are This option is not supported at this time By default this D visible option is not selected 9 Near line objects access This option is not supported at this time By default this 5 granted option is not selected Supports Presentation If this option is not selected the default then Infinity LX States will not return a series with PR modality in a DICOM C FIND query or DICOM C MOVE Retrieve Additionally if this option is not selected the PR modality will not be exported from Infinity LX Supports Key Object If this option is not selected the default then Infinity LX Selection Documents will not return a series with KO modality in a DICOM C FIND query or DICOM C MOVE Retrieve Additionally if this option is not selected the KO modality will not be exported from Infinity LX Supports Structured Selecting this option indicates that Infinity LX will support Reports the following operations for DICOM structured reports e Accept DICOM structured reports e Export DICOM structured reports to a destination Allow a DICOM host to Query Retrieve a DICOM structured report that resides on Infinity LX Codonics Infinity LX User s Manual 4 21 Tab
96. n a RAID 5 configuration there is typically only 4 TB of usable storage The storage capacities that Codonics specifies for Infinity LX refer to usable storage not the total storage available prior to RAID initialization Infinity LX currently supports up to 8 TB of usable storage capacity in its RAID configuration Table 2 1 lists how many typical studies can be stored in 1 TB of storage Table 2 1 Storage Capacity of 1 TB Type of Study CR DR Chest MR Brain CT Abdomen PET CT Body CT Raw Data Typical Number of Typical Total Study Max Studies Stored Images Study Image Size Size on1TB 2 20 MB 40 MB 25 000 200 0 5 MB 100 MB 10 000 400 0 5 MB 200 MB 5 000 1500 CT 1000 PET 0 5 MB 1250 MB 1 600 1 5 GB 5 GB 200 Codonics Infinity LX User s Manual 3 2 o e e 2 9 i T o 2 2 NOTE The storage capacity of 1 TB referred to in Table 2 1 on page 2 1 is a base 10 value decimal number system but the CT image sizes are base 2 values binary number system so the actual image capacity might be slightly less than what is shown in the table Hard Drives Infinity LX uses hard drives that are designed for continuous 24 7 operation for five years in demanding applications such as corporate file servers The Infinity LX hard drives provide better performance than entry level PC drives Fault Tolerant A computer with self contained backup systems that allows continued opera
97. n entire RAID array is in Multiple hard drives in the array have Stop sending studies to Infinity LX and a fault state failed or are missing or data corruption contact Codonics Technical Support in the array has occurred 1 440 243 1198 One of the system hard The system hard drive has failed or has Replace or reinstall the hard drive refer drives slots 11 and 12 is been removed to Replacing a Hard Drive on in a fault state page 7 2 Infinity LX indicates that The RAID battery has exceeded its The RAID battery needs to be replaced the RAID battery needsto rated lifespan If a power outage occurs Contact Codonics Technical Support be replaced data on the RAID array could become 1 440 243 1198 corrupted 8 20 Status Indicators and Troubleshooting Aliowing Remote Access Infinity LX provides a Remote Support tool called LogMeIn Rescue that allows Codonics Technical Support personnel to access Infinity LX remotely and help users with configuration troubleshooting and general product usage questions You must be logged in as a user with administrator privileges to run this utility NOTE Only a user at the site can initiate the remote access connection to Codonics Technical Support This prevents unauthorized access to Infinity LX CAUTION Initiate a remote access connection to Codonics only when requested by Codonics Technical Support personnel Infinity LX must be connected to a LAN that has Internet ac
98. n the front panel of the replacement chassis 13 Plug the power cords into the power outlet or UPS 7 18 Maintenance Maintenance 14 If there is a UPS disconnect the UPS serial cable from the rear of the failed chassis and connect it to serial port of the replacement chassis The following illustration shows the cable connections for Infinity LX with a UPS 0 U f oo og egoe zo ZOZOYOZOZOE sn ORTRCRERTEE OROF O 008080208 te 020020000000 POLO 20802020808 a O SAOE0 0228250600 e Io o o OB OBER OR OB FROR DSB CRKO A e e OCR ND We S RD iy aT D llel e ROROR V SISI a Ofii ig O OJ OJ O 2 1 71 Oo res TTC i D lal amp pp _ y Lo ol O amp Se 0e0 7 19 Codonics Infinity LX User s Manual 15 If there is a monitor keyboard and mouse power off the monitor then move their connectors from the failed chassis to the corresponding connectors on the replacement chassis The following illustration shows the cable connections for Infinity LX with a monitor keyboard and mouse a toooontnnoonnonoooonnpg 16 If a monitor is installed press the monitor power button
99. n the monitor and the VGA port on the chassis connector panel Ora a 3 Connect the monitor power cord to a power outlet preferably the same outlet as the chassis or UPS power cord Setting Up the Hardware Configuring System Information A KS To configure the system information Before using Infinity LX for the first time system information must be configured on the SmartDrive CAUTION Do not reconfigure or modify the software except as described in configuration tasks documented in this manual 1 Insert the SmartDrive into a USB port on a PC The SmartDrive will appear as a standard USB flash drive 2 In Windows navigate to and run the Configurator exe file which is stored at the root level of the SmartDrive DER Fie Edit View Favorites Tools Help gt p gt Search Folders EJ File and Folder Tasks Configurator exe Make a new folder Publish this folder to the Web profiles Configurator exe EX Share this folder Other Places iQ My Computer My Documents My Network Places Details CODONICS D Removable Disk File System FAT32 Codonics Infinity LX User s Manual 3 19 n 2 le i T gt D IT D a o p w ua A 6 re The Configurator application opens Infinity Configuration Tool Configurati
100. n with Infinity LX refer to Configuring a Typical DICOM Host on page 5 1 In addition Infinity LX must be configured to allow the DICOM station access For access setup information refer to Allowing DICOM Station Access on page 4 13 Once configuration is complete the Infinity LX should successfully accept DICOM Store requests along with DICOM Query Retrieve requests To ensure that the Infinity LX and DICOM station are configured properly perform the following test steps a fe 5 e D 5 2 J a 5 e 1 Select a sample DICOM dataset from the DICOM station that is modality workstation PACS workstation etc and store the data to Infinity LX Specific details about how to perform a DICOM Store operation from the DICOM station are usually found in the product s documentation 2 Go to any Windows XP Vista computer on the same network as the Infinity LX Codonics Infinity LX User s Manual 5 3 5 4 3 Establish a Windows Remote Desktop Connection to Infinity LX For instructions on how to establish this connection refer to Logging In Using Remote Desktop Connection on page 4 2 4 Open and log into the Study Manager from the Remote Desktop Connection For more information refer to Starting a Study Manager Session on page 6 2 ya NOTE The Study Manager can be displayed in either the English or Japanese locale la 5 Search the Infinity LX database for the DICOM dataset se
101. nal based on proprietary configurations 3D reconstructions and multi frame studies can be quickly saved and retrieved for future reconstruction or review Automatic image management removes older studies tagged for temporary storage when space is needed Infinity LX provides radiology departments with a simple solution that saves time and money when storing data not requiring long term archive on centralized servers Quarantined Storage The increased use of CDs and DVDs for image distribution is changing the way medical facilities manage studies brought in by patients Often the unknown nature of the data on the disc combined with the cost of storing them permanently on a central PACS makes institutions reluctant to import them into their own networks When combined with the Codonics Integrity Medical Image Server Infinity LX provides a low cost alternative for storing studies from CD or DVD eliminating concerns about lost discs storage costs and foreign data mixing on the hospital network Infinity LX simplifies disc management and viewing Ease of Setup and Use Infinity LX includes many preconfigured settings for common applications so users can begin utilizing the system quickly While the Infinity LX default configuration can be up and running within minutes it is also highly customizable with a rich set of features including DICOM store query retrieve storage commit on the fly image compression workstation access control an
102. nd then power down the device refer to Removing Power to Infinity LX on page 4 32 e Damage to a power cord may cause fire or shock hazard When unplugging a power cord hold it by the plug only and remove the plug carefully If a power cord or power supply needs to be replaced replace it only with another Codonics power cord or Codonics power supply Alternatively replace it with a power cord or power supply manufactured specifically for your power configuration Codonics Infinity LX User s Manual xix Preface e If the device is smoking or making unusual sounds power off and unplug the device immediately Do not insert foreign objects of any kind into the device doing so can constitute a safety hazard and cause extensive damage e Do not place any liquid containers on the device If for some reason liquid seeps into the device power off the device and unplug the power cord from the source outlet If used without taking corrective measures the device may be damaged Do not use the device near flammable gases Pr caution d Emploi Ne jamais brancher cet appareil sur une source d alimentation lectrique dont la tension ou la fr quence diff rent des valeurs indiqu es 100 240 VAC 50 60 Hz Utiliser uniquement le bloc d alimentation fourni avec l appareil numero de pi ce Codonics SP 0043 7 e Avant de remplacer le bloc d alimentation ou le chassis principal veuillez
103. ne hard drive in a RAID array has failed or one of the power supplies has failed Codonics Infinity LX User s Manual 8 7 Oo ph a8 os co os p O gt o CR 5 Te gt Q Table 8 2 Status and Navigation Tree Icons Status Icon Description red cross next to a navigation tree entry indicates a fault condition A fault condition occurs when Infinity LX requires immediate attention due to hardware failure and or cannot process storage and retrieval requests The specific fault condition is displayed in the Dashboard status message area and in the information panel area The combination of a red cross in a status icon and a steady Main Chassis Drives X Temperatur Examples are two hard drive failures in a RAID array or no network connection Table 8 3 LED Status Indicators Status Icon Description Green On Ready condition The ready condition indicates that Infinity LX is properly configured and can process storage and retrieval requests The message Ready also displays in the Dashboard status message area Yellow On Alert condition An alert condition occurs when Infinity LX requires user attention but can still process storage and retrieval requests The specific alert condition is displayed in the Dashboard status message area and in the information panel area Red On Critical or fault condition A critical condition occurs when Infinity LX is at risk of ent
104. ng records 6 44 configuration number xvii configuration parameters 3 20 Configurator application 3 19 Configurator exe file 3 19 connector panel location 3 5 conventions used in this manual ix to x Convert PET images to CT images DICOM station export property 4 28 C STORE granted DICOM station grant property 4 20 Customer Service contact information 7 22 Dashboard 8 6 data sources 6 6 date setting 4 12 default orientation Study Manager 6 21 Desktop tab 6 8 6 13 DICOM Called AE Title 5 1 configuring host to support Infinity LX 5 1 Infinity LX as Storage Class Service Class Provider 5 1 DICOM communication DICOM configuration property exporting records 6 44 DICOM destination server configuring 6 42 Codonics Infinity LX User s Manual 1 1 1 2 DICOM objects non image 4 22 DICOM Query testing 5 3 DICOM Retrieve 5 2 testing 5 3 DICOM station properties Export tab 4 26 Grant tab 4 20 Identification tab 4 18 Import tab 4 22 DICOM stations allowing access to Infinity LX 4 13 DICOM Store 5 2 testing 5 3 DICOM VR format DICOM station import property 4 24 Dictionary DICOM station export property 4 27 Dictionary DICOM station import property 4 25 disc drive location 3 5 display modes Study Manager 6 29 disposal requirements xxvi DNS server network parameter 3 21 Dual Orthogonal mode Study Manager 6 33 Email parameters 3 21 email receiving status by 8 12 Ethernet cable ins
105. nity LX indicates that a UPS is not connected The UPS is running on battery power The UPS is overloaded The UPS battery needs to be replaced One of the two power supplies failed The serial cable between Infinity LX and the UPS is disconnected Infinity LX is connected directly to a power outlet and not to a UPS The UPS is not receiving power The devices connected to the UPS are drawing more power than it is intended to supply The UPS battery has exceededits rated lifespan A power outage may cause the UPS to fail if the battery is not replaced Replace the failed power supply refer to Replacing a Power Supply Module on page 7 9 Make sure that the serial cable is connected It is strongly recommended that Infinity LX be connected to an approved UPS Verify that the UPS is plugged in and receiving power For additional information or assistance contact Codonics Technical Support 1 440 243 1198 Make sure that only Infinity LX is connected to the UPS Follow the manufacturer s instructions for replacing the UPS battery Hard Drives RAID Storage capacity alert Storage capacity fault Storage use is at 96 98 Storage use is at 99 so Infinity LX is no longer accepting storage requests Status Indicators and Troubleshooting Remove unnecessary studies or increase storage capacity For additional information or assistance contact Codonics Technical
106. ns the Patient Information dialog box Patient Information Database Identification Address Medical Alerts Family Name Doe First Name John Patient ID CT 1111 Middle Name Maiden Name Prefix Mr Birthdate 10 21 1929 w Age 79 years Suffix Sr Sex OMale Female Insurance Central Insurance Company Address 5555 N Highland St Phone 99000 MAINTOWN Home 142 555 1234 Work 142 555 2464 Country NEVERLAND Information data in either the Study or Patient Information dialog box is view only unless it comes from a database In this case editable fields are shown in white and the Save button is enabled TS 1 Edit the information in the Information dialog box as needed To edit record 2 Click the Save button to save your changes information o 2 o 2 le no 2 i 77 Codonics Infinity LX User s Manual 6 41 Exporting Records Studies series or images can be exported from the Infinity database to DICOM destination servers that are configured in Study Manager Only the admin user can export records Configuring a DICOM Destination Server TS 1 Log in to Study Manager as the admin user To configure a 2 Open the Options menu and click DICOM Settings DICOM z destination The DICOM Configuration dialog box displays His 3 Go to the Connections configuration tab DICOM configuration x General configuration Connect
107. nt from the DICOM station by entering appropriate patient information For information about how to perform a search refer to Searching for Data on page 6 9 6 Ensure that the DICOM dataset sent from the DICOM station appears in the search results list A successful search indicates that the dataset sent from the DICOM station was properly stored to the Infinity LX database 7 Right click on the DICOM dataset sent from the DICOM station and select Send to Desktop from the pop up menu For more information on the Study Manager refer to Understanding the User Interface on page 6 4 8 Expand the tree view and ensure that the DICOM dataset has all expected data For instance if the study sent from the DICOM station contained 100 patient images Study Manager should display 100 images in the tree view For more information on managing study information refer to Study Manager Desktop Tab on page 6 8 9 Return to the DICOM station to test Query Retrieve capabilities if this functionality was configured on the DICOM station 10 Perform a DICOM Query Retrieve on the DICOM station Query a study that has already been stored to the Infinity LX database Specific details about how to perform a DICOM Query Retrieve operation from the DICOM station are usually found in the product s documentation Storing and Retrieving 11 Ensure that the DICOM dataset Query Retrieved from the Infinity LX database now resides on the D
108. o the selection window Select Browse za Go back to the selection window to select an ie additional series or patient The current series remains open Print Send the current image window to a Windows printer The Codonics Horizon Imager configured with the PostScript option can be used to create high quality color and grayscale prints Tile Mode Display multiple images from the same ag series Magnifying Glass Magnify a portion of the active image Select se zoom factor by right clicking in the magnified area from x2 to x8 Reset Window Level Resets window levels to the original values se Polarity as Changes the polarity of the active series lt black becomes white white becomes black Synchronize Slices In this mode the frames displayed that are in 4 the same orientation will be synchronized Hide Display o Toggle the display of graphics drawing and Graphics ast measurement tools Distance Determine the distance between two points Measurement Nee in the active image 5 Angle Measurement a Determine an angle within the active image amp V a a Pixel Measurement pix Display the pixel value of a point within the S ra active image g Codonics Infinity LX User s Manual 6 17 Table 6 4 Basic Toolbar Commands Continued Icon Description Calibration ATA Calibrate the active image pixel size Allows for measurement of a known size element within an image and allows for input of the known size Mosa
109. o user action is required Rebuilding The system is rebuilding No user action is required information on the drive The specific to this drive However if rebuild operation can take up to the drive being rebuilt is the hot 12 hours spare another drive in a RAID array has failed Failed The drive has failed The failed drive must be replaced immediately If a hot spare drive is installed Infinity LX will automatically use this drive and enter Rebuild mode For complete replacement instructions refer to Replacing a Hard Drive on page 7 2 Missing The slot contained an installed Insert a working drive drive that was in use but is now immediately missing For complete replacement instructions refer to Replacing a Hard Drive on page 7 2 Empty The slot is not being used No user action is required For more information about the hard drive concepts and operating oo ph a8 os co os D O gt o O O BE 50 Q o gt Q states refer to Chapter 2 Codonics Infinity LX User s Manual 8 11 Receiving Status via Email In addition to using the front panel or System Status user interface Infinity LX can automatically send an email to the system administrator when alert critical or fault conditions occur For information on how to configure the email addresses that will receive alert critical and fault notifications refer to Configuring System Information on page 3 19 Receiving St
110. ol DICOM station icon E access to Infinity LX i stant Do 5 23PM 2 Open the Administration tool Codonics Infinity LX User s Manual 4 13 3 At the login enter the administrator user name admin Connection 9 User Database Infinity x omes Vd NOTE Entries in the User field are converted to uppercase automatically 4 Enter the administrator password the default is codonics Click the OK button The Administration tool displays 6 Click DICOM Stations Click DICOM Stations File Ww Setup Control Help a ol Setup Looe g 4 14 Setting Up the Software The DICOM Stations list and toolbar display 7 Click the Add button Click the Add button F Administration DICOM Stations Help a Xe Kind Modality open Ey nf The DICOM Stations dialog box displays 8 Select the preconfigured station wn 2 2 i T gt D wn D p DICOM stations x Copy initial parameters from click Cancel if you want to keep the default parameters Select the default station OK Cancel Click OK 9 Click the OK button Codonics Infinity LX User s Manual 4 15 4 16 The DICOM Station s Properties dialog box displays DICOM Station s properties x Identification Grant Import Export Kind Workstation xl Modet Unknown z Alias CT Stati
111. on Site PCRS Ete Your Facility Name iter English X GICK ETa Your Administrator ema Purge Temporary Studies amp Network Gateway SMTP Server DNS Server SMTP Username System Name SMTP Password Enter the configuration parameters for your site In the Site panel enter the site name and site contact In the Network panel enter the Infinity LX IP address and other network parameters For a description of these parameters refer to Table 3 1 When you have completed entering the system configuration parameters click the Save button and close the window Unmount and remove the SmartDrive from the PC Insert the SmartDrive into its Infinity LX USB port Table 3 1 Configuration Parameters Parameter Description Site Parameters Site Name The name to be used to identify your site Site Contact The name of the Infinity LX administrator 3 20 Setting Up the Hardware Table 3 1 Configuration Parameters p Parameter Description 5 Network Parameters LS gt IP Address The device s IP address is entered Static z through the Configurator Subnet Mask Subnet mask being used for the subnetwork 5 to which Infinity LX is connected This defines which part of the IP address is the subnetwork and which part is the device address Gateway IP address of the gateway for the subnetwork to which Infinity LX is connected DNS Server DNS server host name or IP address System Name Specifies the network name
112. on 1 DICOM parameters AE Title CT_1 Host 1192 168 1 100 Port 104 J Get IP address from incomming connection J Secure connection Private DICOM tags lt none gt X J Check IP Address at connection Cancel 10 Configure the station properties The topics that follow describe the properties on each of the tabs in this window 11 When you have finished configuring the properties click the OK button The station is added to the DICOM Stations list GP Administration DICOM Stations M File view Actions Help Setup Kind Alias AE Title Host Modality open open lt lt automatic gt gt 104 Workstation CT Station 1 CT_1 192 168 1 100 104 DICOM station added to the list 12 Add other stations as needed Setting Up the Software TIP Using an existing DICOM station as a template for a new station To create a new DICOM station entry that is based on one of the existing station entries click the Add button on the DICOM Stations list screen select the desired existing entry in the DICOM Stations dialog box and click the OK button The new station s property settings in the DICOM Station s Properties dialog box will match the station entry that you selected 13 When all stations have been added click the Save All button Click Save All gP Aliministration DICOM Stations Fe View Actions Help Setup 5 Kind as Modality open Dicom Stations rf
113. on de chiffon imbib de benz ne d essences d insecticides ou d autres solvants N utilisez jamais solution base de p trole Pour nettoyer la baie de chassis principale l teindre en utilisant le bouton d arr t puis l interrupteur situ l arri re et n oubliez pas de d brancher le c ble secteur Nettoyez la baie avec un tissu doux l g rement bumidifi avec une solution base d eau et de savon non corrosif Laissez s cher avant de remettre en fonction le syst me Maintenance Precaution Infinity LX includes several redundant systems and a robust user warning system to decrease the likelihood of permanent data loss It is imperative that users act to prevent permanent data loss when Infinity LX indicates that there is a problem Failure to do so may invalidate the system warranty and will jeopardize system data Pr caution d Entretien L appareil Infinity LX comprend plusieurs syst mes de redondance et un syst me d utilisateur renforc avec des avertissements afin de r duire le risque de la perte des donn es L inactivit en cas d avertissement risque d endommager la base de donn es Image Formats Supported Infinity LX supports the following image formats e DICOM 3 0 e All standard Storage SOP classes e Private Storage SOP classes Formats d Image Accept s Infinity LX accepte les formats d image suivants e DICOM 3 0 e Tous les standards SOP classes e Adaptation du Stockage de
114. on has formed Wait until the condensation has evaporated You can speed up the evaporation time by moving the device to a drier location e Ventilation slots and holes are provided on the front and rear of the device Place the device on a level stable surface and locate it at least 10 cm 4 in from walls to ensure proper ventilation CAUTION Adequate ventilation is required for proper operation of the device e Do not place objects on top of the device e Infinity LX is designed and tested to meet product certification requirements for use in general administrative and information processing environments within medical facilities Infinity LX is not designed or certified for direct patient contact or for use within 1 83 m 6 ft of a patient or in explosive environments where flammable gases such as anesthesia or oxygen might be present Codonics Infinity LX User s Manual xxi xxii A A Preface WARNING Grounding reliability can be achieved only when Infinity LX or its uninterruptable power supply UPS is connected to an equivalent receptacle marked Hospital Only that is Hospital Grade WARNING Customers might consider using an appropriate isolation transformer or a medical grade UPS in environments that require less than 300 uA chassis leakage Please check local regional and hospital specific ordinances to determine the applicability of any all standards based on the intended use and placement of Infini
115. onal Mode aa aol oO Display mode Triple ortho Fusion F F F ho Anatom T Blend gt Funct Window levels ic IF SUV Scale Mosaic view MOM 4 Func Anat Fus o LI id ly Slice thick mm Pa al 3 3 The Triple Orthogonal mode features three orthogonal views for synchronized display of the anatomical functional and fusion images The cross target position and the projection cine are synchronized on all views 6 34 Managing Studies Mosaic Only Mode e Display mode Horizontal Mose_ Fusion F F PM al Anatom Tl Blend Funct Window levels SUV Scale Mosaic view vw Ww Func Anat Fus aoa amp Slice thick mm 0 978 F M a Oa ES The Mosaic Only mode features three views in a synchronized mosaic display Functional Anatomical and Transparency fusion A synchronized cross target is displayed over the views to help localize the same anatomical point on the three views o 2 o 2 le no E oO 77 Codonics Infinity LX User s Manual 6 35 6 36 Advanced Viewing Considerations Advanced viewing modules work only on images for which orientation and image position data has been coded by the modality Also all the images of the input series must have the same slice thickness and regular spacing between slices If this is not the case the following error message displays
116. panel and unplug the Infinity LX power cords Clean the enclosure with a clean soft cloth or towel slightly moistened with a mild soap and water solution Allow the enclosure to completely dry before operating Infinity LX again AN CAUTION Always power off Infinity LX and disconnect its power cords before cleaning Resume operation only after the surfaces are completely dry Codonics Infinity LX User s Manual 7 1 CReplacement Procedures A A A To replace a failed hard drive 7 2 Maintenance CAUTION Infinity LX includes several redundant systems and a robust user warning system to decrease the likelihood of permanent data loss It is imperative that users act to prevent permanent data loss when Infinity LX indicates that there is a problem Failure to do so may invalidate the system warranty and will jeopardize system data Replacing a Hard Drive If a hard drive fails it should be replaced immediately CAUTION Do not remove more than one hard drive at a time This could cause permanent data loss Failure to comply with this caution may void the Infinity LX warranty CAUTION To avoid data loss make sure that you are replacing the failed drive To identify the failed drive the drive s status light will be red 1 Do not shut down Infinity LX 2 Open the chassis door 3 Make sure that you properly identify the failed hard drive Its status light will be red BE D o
117. port from PACS database Use Routing to import in PACS database 10 Click the OK button to save your changes and close the dialog box 11 On the Connections configuration tab click the OK button to close the DICOM Configuration dialog box The destination server s icon is added to the Study Manager left sidebar selection 1 Study File View Options a E Study list P Database DICOM Destination o 2 o 2 le no 2 i 77 cCodonics Infinity LX User s Manual 6 45 IF To export a record Exporting a Record aw NP Log in to Study Manager as the admin user Right click on the study series or image to be exported In the pop up menu click Export study The Connection Selection dialog box displays Connection Selection Database DICOM Destination Description Server name perm address 10 1 90 169 port 104 Client name DxDCMserver port 104 ove 5 Select the destination server then click the OK button 6 You are prompted to confirm the export operation Export confirmation Do you confirm that you want to export 1 studylies to the connection DICOM Destination C Key images only Click the OK button to proceed with the export The Study Manager import export activity icon displays in the Windows taskbar tray to indicate the status of the record transfer 6 46 Managing Studies 8 To
118. ports 3 6 reboot from local monitor 4 28 from Remote Desktop Connection 4 28 reboot using chassis power button 4 30 record icons 6 14 status indicators 6 15 records deleting 6 48 deleting with their parent records 6 48 editing 6 41 exporting 6 42 to 6 47 exporting procedure 6 46 viewing 6 40 reinitialize the volume Study Manager 6 24 reinstalling Infinity LX software 7 23 remote access to Infinity LX by Technical Support 8 21 Remote Desktop Connection to access Infinity LX 4 2 Remote Support tool 8 21 remote web access 4 2 Reslice mode Study Manager 6 20 restart from local monitor 4 28 from Remote Desktop Connection 4 28 restart using chassis power button 4 30 RSS 2 8 Feedreader 8 13 receiving status by 8 12 URL for Infinity LX 4 12 8 12 Ss safety location of labels xiii precautions xix to xxi SAS 2 7 SAS port location 3 5 SATA 2 7 SATA II 2 7 secondary image acquisition systems 4 13 5 1 Secure connection DICOM station identification property 4 19 Selection window 6 4 6 5 sorting data 6 8 serial number label xvii serial port location 3 6 Service Class Provider SCP 5 1 shipping Infinity LX 7 24 shutdown from local monitor 4 28 from Remote Desktop Connection 4 28 using chassis power button 4 30 Site Contact site parameter 3 20 Site Name site parameter 3 20 Site parameters 3 20 slice thickness Study Manager 6 22 slices reconstructed Study Manager 6 30 SmartD
119. rage capacity Codonics Infinity LX User s Manual 8 15 Table 8 5 Troubleshooting Continued Problem An audible tone is not being sounded when errors occur or when Infinity LX successfully starts up The default usernames admin manager or operator do not work System performance is slow When accessing Infinity LX via Remote Desktop Connection the Windows graphics appear grainy A specific Windows application cannot be found A virus has been detected Infinity LX does not shut down within 2 minutes of the initiation of the shutdown 8 16 Possible Causes The Mute button was pressed disabling the audible alert tone An incorrect username or password is being used Caps Lock is on when entering the password Many store and retrieve requests are being processed There is an alert critical or fault condition The PDU size needs to be increased The Remote Desktop Connection Display Colors setting is not set high enough A remote user who is logged in from the Remote Desktop Connection application is looking at the Infinity LX file system when they think they are looking at their local file system The system software has been infected with a software virus The software did not shut down properly Status Indicators and Troubleshooting Solutions Press the Mute button to enable the audible alert tone Verify the entry of the username and password T
120. rd drives A RAID 1 configuration provides one drive of fault tolerance This means that if either drive fails the system will continue to run When the failed drive is replaced the RAID controller automatically rebuilds data onto the new drive If both drives fail at the same time all data is lost The following diagram illustrates how the same data blocks are stored on both of the RAID 1 drives RAID 1 Data Block 1 Data Block 1 Data Block 2 Data Block 3 Data Block 4 Data Block 4 Disk 0 Disk 1 Data Block 2 Data Block 3 Infinity LX uses mirrored hard drives to store the operating system application software and database When a RAID 1 drive fails the failed drive s status light turns red an audible alarm sounds the System Status user interface status indicators are updated an email is sent to the administrator and an RSS article is posted 3 77 D 2 a e e 2 e iv T A no Codonics Infinity LX User s Manual 2 4 RAID 5 A RAID 5 configuration always uses three or more hard drives that are the same size e g all 1 TB Data is distributed evenly across the hard drives to improve performance using a technique known as striping Also extra information is recorded for fault tolerance called parity The parity information always requires one drive out of the RAID set e g a RAID 5 drive set with four 1 TB drives will provide approximately 3 TB of usable d
121. re applications can affect system performance or interfere with system operation CAUTION Infinity LX is designed to run only authorized Infinity LX software Do not directed to do so by Codonics Technical Support 1 440 243 1198 A full installation removes all files including all Windows files all Infinity LX application files except the Infinity LX configuration files and the studies database CAUTION Do not perform a full Infinity LX software installation or reinstallation unless Load the Operating Software disc in the disc drive on the front panel tS To install Infinity LX 2 Shut down Infinity LX as described in Shutting Down and software Rebooting on page 4 28 ie Wait a few seconds then momentarily press the Infinity LX Power button to restart the system D E Power button E Ve F O O O TT aT m ANAM TANAN TANAN nian Codonics Infinity LX User s Manual 7 23 7 24 The Operating System disc will eject after approximately 20 minutes 4 Wait 30 to 60 minutes for the installation to complete Six audible beeps indicate when software installation is complete Preparing Infinity LX for Shipping Maintenance If you have to ship Infinity LX for any reason for example to return it to Codonics for service you must use the original box and packing materials If you do not have the original box and pac
122. removed when needed Infinity LX has hot swappable hard drives in special carriers internal cooling fans and a redundant power supply with dual modules that allows either power supply module to be replaced without the need for tools Cold Swap A cold swap is a replacement of a hardware component that can be performed only when the system is powered off A system that uses cold swap components usually requires opening the chassis and changing the failed component by disconnecting cables and removing screws Infinity LX has very few cold swap parts Only the motherboard CPU fan and internal chassis electronics are cold swap components These require a chassis swap Hot Spare Drive with Automatic Copyback Infinity LX supports one optional hot spare drive with Automatic Copyback to protect all three RAID sets in the Infinity LX chassis Drive slot 13 in the chassis is permanently allocated for the Hot Spare Drive Terms and Concepts The hot spare drive is an extra hard drive installed in the system that is automatically used to build the array when any other RAID hard drive fails This reduces the amount of time a system is vulnerable to a second drive failure that will result in total data loss on a RAID set Automatic Copyback is a feature that waits for the failed drive to be replaced then automatically copies the data from the hot spare drive back to the replaced drive The process takes about four hours Once Automatic Copyba
123. ring operations that produce Codonics products including packaging no ozone depleting substances such as chlorofluorocarbons methyl chloroform and carbon tetrachloride are used Fabrication Aucun composant susceptible de d truire la couche d ozone ne sont utilis s lors de la fabrication emballage inclus des produits Codonics 5 e 3 2 e 5 enaze snopiezeH Codonics Infinity LX User s Manual A 3 Specifications specifications English User Interface Remote access via the web and Windows Remote Desktop Connection application Optional local monitor keyboard and mouse Web Browsers Supported Internet Explorer 7 FireFox 3 DICOM Server Protocols DICOM 3 0 Store Storage Commit Query Retrieve Storage 1 8 TB using SATA II 3 5 in hard drives Performance 50 MB sec DICOM Store Redundancy RAID 1 mirroring for operating system and database RAID 5 for study data Hot swap hard drives Hot swap power supply modules 1 1 Hot swap internal cooling fans Hot spare online hard drive with Automatic Copyback optional Compression JPEG Lossless and Lossy compression of DICOM images optional Alarms Drive failure cooling fan failure power supply failure over temperature warning UPS status Status Notifications Web email RSS built in visual and audible alarms 7 Support Remote diagnostic support via Internet LogMeln E Rescue z 9 UPS Fully integrated UPS support with
124. rinted on the SmartDrive s label System configuration information This includes site network locale and email notification information Codonics Infinity LX User s Manual 4 33 lt gt Storing and Retrieving CContiguring a Typical DICOM Host Infinity LX is a DICOM Storage Class SCP Service Class Provider that can accept incoming DICOM Store associations Any system that supports DICOM Store should work with Infinity LX Typical DICOM stations that would connect to Infinity LX include e Modality workstations e PACS workstations e Primary and secondary image acquisition systems Configuring a DICOM station to send images to Infinity LX requires the following settings a 5 D 5 2 J oy 5 Co e The Infinity LX host name or IP address The Infinity LX DICOM TCP port The Infinity LX TCP port is 104 e DICOM AE Title Infinity LX uses the Called AE Titles listed in Table 5 1 on page 5 2 Most DICOM stations require these settings to successfully connect to the device Specific details about how to configure a DICOM station are usually found in the product s documentation Codonics Infinity LX User s Manual 5 1 Also the DICOM station must be configured on Infinity LX to allow access to that station For more information refer to Allowing DICOM Station Access on page 4 13 CStoring and Retrieving Studies DICOM Store and DICOM Retrieve are the primary
125. rive installing 3 7 USB port location 3 5 SMTP Password email parameter 3 22 SMTP Server email parameter 3 22 SMTP Username email parameter 3 22 software license code 4 33 specifications B 1 to B 4 starting up Infinity LX 3 23 startup troubleshooting 8 15 status lights interpreting 8 3 status lights location 3 4 Storage Commitment DICOM station import property 4 24 Storage Commitment granted DICOM station grant property 4 21 striping 2 4 studies storing and retrieving 5 2 Study Completed DICOM station import property 4 25 study data backing up 7 1 Study List tab 6 7 6 11 Study Manager advanced viewing considerations 6 36 basic toolbar commands 6 17 cine control 6 26 clipping box 6 25 data sources 6 6 default orientation 6 21 DICOM destination server configuring 6 42 display modes 6 29 Dual Orthogonal mode 6 33 exiting 6 49 Fast Preview option 6 21 Fast Rotate option 6 22 Fusion mode 6 27 fusion options 6 31 Image window 6 16 layouts 6 21 main window 6 4 measurements 6 32 Codonics Infinity LX User s Manual l 5 1 6 Study Manager cont MIP display 6 30 MIP mode 6 23 Mosaic Only mode 6 35 MPR mode 6 19 orthogonal display 6 30 Orthogonal mode 6 29 orthogonal views 6 25 overview 6 1 patient folder icons 6 13 patient records viewing 6 14 record icon status indicators 6 15 record icons 6 14 records deleting 6 48 records deleting with their parent records
126. rive status Network 1 activity Network 2 activity The following table explains how to interpret the state of the front panel status lights o V 12 os co os 9 2 O gt o CS 5 TE 2 Table 8 1 Front Panel Status Light Indications Status Light Indications Power Blue Power on Network activity Green There is activity over the network connection Hard drive power Blue Power on Hard drive status Off No disk activity Green Disk activity Red Hard drive fault Codonics Infinity LX User s Manual 8 3 8 4 System Status User Interface Detailed status information about Infinity LX is available in the System Status user interface TS From a web browser running on a PC in the same network as Infinity LX enter the Infinity LX IP address or host name as the To view status URL address information using the OR System Status user interface If connected to Infinity LX by a Remote Desktop Connection or a local monitor keyboard and mouse locate and open the System Status user interface icon on the Infinity LX desktop System Status tool icon 12 Stan r POA 5 23PM Status Indicators and Troubleshooting The System Status user interface s main screen displays The following figure identifies the major areas of the tool The following topics provide information about using each of these areas Navigation tree Dashboard Wed Sep 16 9 4 T
127. rom Enter the Infinity LX the drop down list IP address Computer 492 168 1 10 Username admin i Enter the username admin Password eeeeeesee Domain n _ Enter the password C Save my password the default is codonics Connection settings a Save current settings or open saved connection Close Help Options lt lt Click Connect 6 Enter the administrator user name admin Enter the administrator password the default is codonics Click the Connect button A Windows session is started and the Windows desktop displays For information about how to log out shut down the system or reboot the system refer to Logging Out on page 4 28 and Shutting Down and Rebooting on page 4 28 CAUTION When shutting down a PC make sure that you are actually shutting down the PC and not Infinity LX from an open Remote Desktop Connection session Doing so could inadvertently disconnect other Infinity LX users or interrupt drive recovery operations resulting in data loss Codonics Infinity LX User s Manual ty 4 5 n 2 2 i T gt D wn D p 4 6 IF To log in using a local monitor keyboard and mouse Logging In Using a Local Monitor Keyboard and Mouse If your Infinity LX includes a locally connected monitor keyboard and mouse you can log in from the local user interface 1 Make sure that Infinity LX and the monitor are
128. s e The Power button is used to power Infinity LX on and off e The Status lights indicate system status e The Mute button stops the audible status alarm if it is on ya NOTE After pressing the Mute button it might take up to ten seconds for the audible alarm amp to stop 3 4 Setting Up the Hardware e The hard drives are housed in the Hard drive slots e System configuration information and utilities are stored on the SmartDrive which is inserted into the front panel USB port e CD DVD discs can be loaded in the Disc drive Infinity LX Rear Components The following illustrations show the components and input output ports at the rear of Infinity LX Power supplies Power supply status lights Power supply connectors Power supply switches Connector panel Serial Attached SCSI SAS port Infinity LX rear panel components Codonics Infinity LX User s Manual 3 5 wn D f 2 Le i T gt D IT 2 a o D 3 6 VGA port USB ports Ethernet port 2 Infinity LX connector panel ports Setting Up the Hardware Dp D 4 Serial port Ethernet port 1 not currently supported installing the Hardware A A IS To install the power cords Ethernet cable and SmartDrive CAUTION Only trained users should install and configure the
129. s SOP classes sp cifiques aux constructeurs Medical and Patient Information Infinity LX log files might contain patient information Use caution when distributing log files Codonics Infinity LX User s Manual XXV xxvi QDisposal Requirements Preface Disposal of this product and consumables shall be in accordance with all applicable laws and regulations in effect at the locality at the time of disposal For additional information refer to Appendix A Hazardous Material Information Conditions et R gles d Utilisation L utilisation de ce produit doit tre conforme toutes les lois et r glements applicables sur le lieu d utilisation European Disposal Requirements Codonics products and electronic accessory devices are not to be discarded or recycled rather they are to be returned to the manufacturer Contact Codonics directly or by the email link provided for the latest information concerning e Identification of the country specific Importer Distributor Producer e Product return and treatment of our electronic products Manufacturer Codonics Incorporated 17991 Englewood Drive Middleburg Heights OH 44130 USA Phone 1 440 243 1198 Fax 1 440 243 1334 Email WEEE codonics com www codonics com weee Codonics products and electronic accessory devices bearing the following symbol are subject to European Directive on Waste Electrical and Electronic Equipment WEEE 2002 96 EC amended by Directive 2003 10
130. se Contact Codonics Technical Support for assistance with advanced DICOM configurations Codonics Infinity LX User s Manual 4 25 DICOM Station Properties Export Tab The Export tab is used to configure how images are exported from Infinity LX to a DICOM station using C STORE C MOVE or C GET The Infinity LX DICOM Server exports images via a C MOVE or C GET and performs manual exporting using C STORE to a DICOM station Table 4 4 describes the station properties that can be set on the Export tab shown below DICOM Station s properties Identification Grant Import Export IV Optimize Presentation Context Negotiation Dictionary defaul Keep Original Transfer Syntax x di Fado fico 1 Low quality high compression 100 High quality low compression D Convert PET images to CT images D Use storage commitment ja Lz Cancel 4 26 Setting Up the Software profile has been copied from an existing one the settings will match the source profile and ya NOTE The default settings indicated in the following table are the application defaults If a not the application defaults Table 4 4 DICOM Station Properties Export Tab Property Description Optimize Presentation Select this option the default to have Infinity LX use the Context Negotiation transfer syntax selected in the accompanying list if supported by the server when exporting images Otherw
131. seeeseeeeeeeess 1 3 Chapter 2 Terms and Concepts WPA e xc His nn A ME nn est E 2 1 Hard Driv S eccna raiione R lire ianieeins 2 2 Fault Tolra ssaa aan Na ENNA RANAR 2 2 RAID iona E E E a a 2 2 RAID Controller 2 3 RAIDE et modes 2 3 RAID 5 4e nid dacs isd cause pee idee tite nan derni re 2 4 RAID Operating Modes 2 5 Hot SWAP na dede teen einen steam lasse ee 2 6 Cold Swap nana nn 2 6 Hot Spare Drive with Automatic Copyback 2 6 SATA and SATA laiss es ep eicaus aeaaea lente cave aaaea cece 2 7 DAS seit ieee aes ahi aati ii oh ieee ey laren hae ee 2 7 ASS SR Sn Or nn EE 2 8 Chapter 3 Setting Up the Hardware Finding a LoCation wz ii cc cciiceeesstseneteiaeceeiessneiteies ceeivieceneinaaeieeneieaes 3 1 COMPONENTS arero ienga eg a tenir san b ere der en doter ee 3 2 Unpacked Components ss 3 2 Infinity LX Front Components 3 4 Infinity LX Rear Component ccccceceeeeeeeeeeeeeeeeeeaeeeeeeeeseeeeeeeeees 3 5 Installing the Hardware 3 7 Installing Power Cords Ethernet Cable and SmartDrive 0 3 7 Installing Hard Drives ccccceeeeseeeeeeeeneeeeeeeecaeeeeeeesaeeeeeeeeaaeeeeeeenaes 3 10 Installing the UPS Accessory 3 14 Monitor Keyboard and Mouse Optional ccceceseeeeseeeeteeeeees 3 18 Configuring System Information ccccceeeeceeeeeeeeeeeeeeeeeeeeeeeeeeseaeeeeenees 3 19 Starting Up Infinity LX
132. shift of 22 5 degrees The MIP is computed in the background A green progress bar shows the computation status upon program startup and after activating the fusion option for the Projection The MIP runs in cine loop mode It can be stopped and restarted using the regular cine loop buttons in the general display of the application A small cross on the MIP display materializes the cross target center on the fusion display Reconstructed Slices Reconstructed slices can be computed from either the functional image or the fusion image These slices are displayed in the lower pane of the Fusion window e Select the orientation of the slices coronal sagittal transverse to recompute the slices in the requested orientation e Change the slice thickness using the corresponding control Slice thickness is always an integer multiple of the original slice thickness Managing Studies Fusion Options Use the dialog bar to choose which views are to be displayed in transparency fusion mode Check the following boxes accordingly e Ortho view the fusion is activated on the three orthogonal planes e Projection the fusion is activated on the MIP display Selecting this option automatically activates the fusion on the ortho view e Mosaic the fusion is activated on the reconstructed images bottom view Select the transparency level using the vertical slider in the dialog bar This slider goes from fully anatomical to fully func
133. ssage Basic product information is returned via email Complete product literature is sent by postal mail QWarnings and Limitations of Use Safety and Compliance Labels Codonics is in compliance with various regulations details of which are listed in Appendix B The Infinity LX safety and compliance label shown below is located on the right side of the chassis shown on the following page This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la Classe B est conform la norme NMB 003 du Canada This product is in conformity with the requirements of EC Council directive 93 42 EEC on the approximation of the laws of the Member States relating to medical devices This product satisfies the Class B limits of EN 55022 and CISPR 22 CODONICS Infinity Medical Image Server Made in the U S A All Rights Reserved E REP CEpartner4U BV Esdoornlaan 13 3951 DB Maarn The Netherlands Phone 31 6 516 536 26 ETL CLASSIFIED c us tad Codonics Inc 17991 Englewood Dr all CONFORMS TG Middleburg Heights OH 44130 USA 3125762 UL STD 60900 1 CERTIFIED TO CAN CSA STD 60950 1 Ja j Ke i
134. sse 1 Danger du Faisceau Laser Le syst me Codonics Infinity LX Medical Image Server contient un lecteur de CD dont la diode laser est de classe sup rieur 1 Pour votre s curit n enlevez pas les caches n essayez pas d ouvrir Vappareil Adressez vous au personnel qualifi en cas de panne Serial Number Configuration Number Date Code and Modification Codes The serial number configuration number date code and modification codes are located on the safety and compliance label which is on the left side of the chassis e The serial number SN uniquely identifies the unit e The configuration number CN details the build configuration e The modifications codes are to the right of the CN number and are a series of 20 numbers When any of these numbers are blocked out that identifies a modification that was made to the unit e The date code is in YYYY MM format below the factory date code symbol Serial number Date code A b SN a XXXXXXXXC XXXX XX CN ae eas XXX P 16 17 18 ka Configuration Modification number codes Serial number configuration number date code and modification codes Codonics Infinity LX User s Manual xvii xviii Preface Potential for Radio Frequency Interference on Device Operation Both portable and mobile RF communications equipment can affect medical electrical equipment including the Codonics Infinity LX Medical
135. ssory failures A standard UPS is not suitable for installation in a patient care area Please check local regional and hospital specific ordinances to determine the applicability of any all standards based on the intended use and placement of Infinity LX CAUTION A UPS is highly recommended to reduce the risk of data loss due to power TS 1 Place the uninterruptible power supply UPS near the chassis and the power outlet To install the UPS 2 Atthe rear of the UPS insert the battery plug 6 Co a 2a Zo Co a a IT CE Co LT a a Setting Up the Hardware 3 Connect the chassis power cords to the UPS gt ar gt e g l o 30825 0 2 te se RO o Xs 1 Xe ZORO z ORO 5 Xe Z o o O xe O amp fe g CAUTION Connect Infinity LX to only high quality electrical power Do not expose Infinity LX to suboptimal power conditions including but not limited to potential loss of power power spikes or over or under voltage conditions WARNING The two power cords connected to the UPS or a wall outlet are the main disconnect for Infinity LX WARNING To d
136. t the orthogonal views are arranged in a 3x1 column and the reconstructed view is displayed to the right of that column Default Orientation rr ra By selecting a default orientation coronal sagittal or transaxial the resliced series is reset to one of the three basic orientations Fast Preview Option Fast Preview When the Fast Preview option is checked the resliced series is displayed without interpolation and only one pixel out of two is computed However the full quality is always applied when saving the new series Uncheck this option for a view of the actual reconstructed series D 5 D 5 a no a Q o Codonics Infinity LX User s Manua 6 21 doni fini 6 22 I Fast Rotate Slice thickness fo 703125 L Fast Rotate Option When the Fast Rotate option is checked the MPR display is not updated while rotating or dragging the reference cross lines The MPR display is updated upon release of the left mouse button When this option is unchecked the MPR display is updated in real time while rotating or dragging the reference cross However for performance reasons the reconstructed series is always displayed in fast preview mode regardless of the status of the Fast Preview check box Slice Thickness Select the number of slices used to construct the 3D model A higher number here can improve response time but may reduce the detail of the reconstruction To view the resul
137. t in the reconstructed volume frame click the F button NOTE Slice thickness is always an integer multiple of the pixel size Managing Studies iS To enable MIP mode Clipping Box Show Reset EE MG MIP Mode D Click the ae button Then click on the MIP tab to activate the MIP mode The MIP is a 3D post process that features three orthogonal views coronal sagittal and transaxial It also features a free angle view and a clipping box to isolate the organs you want to display Every image is visualized with a Maximum Intensity Projection Codonics Infinity LX User s Manual 6 23 D 5 D 5 a a a Q D o 6 24 Dockable Toolbar Options Reinitializing the Volume To reinitialize the volume as it appeared at the first launch click the e button Be aware that the window level is not reinitialized Enabling Volume Rotation a To enable the volume rotation click the 5 button then press the T left mouse button while dragging the mouse The Le button is enabled only on the fourth view free angle view The cube moves like the volume and on each face gives the orientation of the volume e A anterior e P posterior e I left e R right e H head e F feet Alternatively you can also press ALT left button while dragging the mouse to rotate the image Switching Views To switch the free angle view from mosaic view four views to full screen view click the but
138. tab are displayed in the top portion of the tab Patients the currently selected patient is highlighted AJ Selection File View Options a Study list O Desktop Patient ID Birthdate Sex PEER Plitient Name Sas Qoe Doe Jane 0274304559354794 8 13 2019 F Study Date Time Description Accession No Study ID cc Study folder s for the selected patient Note that the patient folder icon indicates the current data source Table 6 1 Patient Folder Icons Icon Description Infinity LX database DE DICOM server g DICOMDIR CD or DVD disc 7 Studies for the currently selected patient are displayed in the lower portion of the tab You can browse the studies series images and reports for the selected patient Codonics Infinity LX User s Manual 6 13 D 5 D 5 a no a Q D o F5 To view the selected patient s records 6 14 Expand or collapse a study or series by clicking its or sign Or simply double click the folder A Selection Eile View Options Database Study list 0 Desktop Patient Name e Doe John Study Date Time 5 amp 11 8 2071 05 04 KIDNEY aM DG aq 06 0 aQ 06 aM DG SERIES 2 102x102 10 8 20 1920 21 10 SERIES 1 102x102 10 12 6 1972 06 52 SERS ete 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 3972 34 102x102 16b 1 1 2 840 114089 1 0 1 167873449 1234559390 397
139. talling 3 7 Ethernet port locations 3 6 European disposal requirements xxvi Export tab properties 4 26 F Fast Preview option Study Manager 6 21 Fast Rotate option Study Manager 6 22 fault tolerant 2 2 Feedreader 4 12 8 12 opening 8 13 using 8 13 From email parameter 3 22 front door 3 4 Fusion mode Study Manager 6 27 fusion options Study Manager 6 31 Index G Gateway network parameter 3 21 general problems 8 15 Get IP address from incoming connection DICOM station identification property 4 19 Grant tab properties 4 20 hard drive slots location 3 5 numbering 3 10 hard drives definition 2 2 installing 3 10 ordering 7 22 power status light 8 3 replacing 7 2 status light 8 3 troubleshooting 8 18 hardware installation 3 7 to 3 18 hazardous material information A 1 to A 3 Host DICOM station identification property 4 19 host DICOM configuring to support Infinity LX 5 1 Hostname DICOM configuration property exporting records 6 43 hot spare drive 2 6 hot swap 2 6 Identification tab properties 4 18 Image compression DICOM station import property 4 23 Image window 6 16 Import tab properties 4 22 indications for use xxvii Infinity LX as DICOM Storage Class Service Class Provider 5 1 audible status alarm 8 2 chassis cleaning 7 1 chassis replacing 7 12 cleaning precautions xxiv Infinity LX cont components front 3 4 components rear 3 5 configuration
140. the system refer to Shutting Down and Rebooting on page 4 28 and then power down the device refer to Removing Power to Infinity LX on page 4 32 Dangers Electriques Le point d exclamation situ l int rieur d un triangle quilat ral repr sente un point d instruction important dans l utilisation de cette appareil A ADRESSEZ VOUS AU PERSONNEL QUALIFIE LE FAIT DE RETIRER LES ETIQUETTES OU DE DEMONTER LE CAPOT ANNULENT LA GARANTIE CET APPAREIL DOIT ETRE RELIE A LA TERRE N EXPOSEZ PAS CET APPAREIL LA PLUIE OU L HUMIDIT EN RAISON DU RISQUE DE FEU OU DE DECHARGES ELECTRIQUES Codonics Infinity LX User s Manual XV xvi gt gt Preface Cet appareil ne doit pas tre utilis comme composant d un syst me d assistance vitale Cet appareil ne doit pas tre utilis dans des conditions o la d faillance de l appareil pourrait entrainer blessure ou mort d homme WARNING Les deux cordons d alimentation sont le syst me de coupure principal de l appareil WARNING Avant d intervenir sur l appareil veuillez toujours l teindre et n oubliez de d brancher le c ble Laser Warning Infinity LX contains a laser diode of a higher class than 1 To ensure continued safety do not remove any covers or attempt to gain access to the inside of this product Refer all servicing to qualified personnel The following label appears inside your unit Class 1 Laser Product Laser Kla
141. thickness and regular spacing between slices If this is not the case an error message displays and the module aborts ire O x X Error Series do not have the same dimensions pixel size or number of slices 6 28 Managing Studies Display Modes Five display modes are available Orthogonal Dual orthogonal Triple orthogonal Horizontal mosaic and Vertical mosaic Switch between those modes using the Display Mode list box Orthogonal Mode ee ma Display mode Orthogonal he W eae af suv I Ortho vie p 8 04 SUV I SUV Scale Mosaic view VW Ww Func Anat Fus CEE Slice thick mm 10 2968 4 Fusion shows a transparency fusion of both image volumes along the three basic orthogonal directions a MIP of the functional or fusion image and a reconstructed series displayed in mosaic mode D 5 D 5 a no 2 Q D o Codonics Infinity LX User s Manual 6 29 6 30 ne Orthogonal Display To toggle the display of the cross target and reference lines click the button HES To toggle the display of the pixel value click the button To change the color of the cross target and reference lines click the button To use the orthogonal view full screen to hide the reconstructed slices click the FF button MIP Display A MIP is automatically computed from the transverse slices of the functional image 32 projections are computed with an angular
142. this condition NOTE When replacing a single power supply module there is no need to power down Infinity LX It will continue to be powered by the second power supply NOTE The illustrations in this procedure depict the top power supply module being replaced 1 Locate the failed power supply module and turn its power switch to Off c fs ae D O o Z 3 Disconnect the power cord from the power supply module Codonics Infinity LX User s Manual 7 9 2 3 5 D 5 O o 4 Loosen the power supply module thumbscrew completely S C2 ane 15 O Q a 1 O 5 Pull the failed power supply module from its slot using the attached handle 6 Mark the failed power supply module as failed 7 Insert the new power supply module into the empty slot 8 Tighten the power supply module thumbscrew completely amp ejO CT Jo 9 Reconnect the power cord to the new power supply 7 10 Maintenance 10 Secure the power cord with the retaining clip a JO ejO Te 1
143. tion when major components fail is said to be fault tolerant Fault tolerance is used to improve system uptime Electro mechanical devices such as hard drives fans and power supplies are the most likely components to fail Designing a system with redundant components is the most common method of implementing fault tolerance Infinity LX includes redundant hard drives cooling fans and power supplies RAID Redundant Array of Independent Drives refers to multiple hard drives configured as a set to increase either the performance or fault tolerance of the system or both Since hard drives are electro mechanical devices that can fail over time RAID is typically used to minimize the risk of data loss by including extra drives in the RAID set that provide one or two drives of fault tolerance Infinity LX uses RAID primarily for fault tolerance It also improves performance Infinity LX uses RAID 1 for the operating system and database and RAID 5 for storing study data For more information about these configurations see their descriptions later in this chapter Terms and Concepts RAID Controller A RAID controller is dedicated hardware inside a computer system that performs all the functions necessary to set up operate and monitor a set of hard drives configured for RAID operation Typically RAID controllers are third party boards added to the system RAID 1 provides mirroring which is 100 duplication of the data on two ha
144. tional Depending on the Blend check box status the transparency is computed as follows e Blend check box not selected the anatomical image is always displayed The functional image is displayed as a transparency overlay intensity varying from 0 to 100 depending on the position of the slider anatomical to functional Blend check box selected the anatomical image is displayed with an intensity varying from 100 to 0 depending on the position of the slider anatomical to functional The functional image is displayed with an intensity varying from 0 to 100 depending on the same slider setting These settings are common to all views displayed in Fusion mode Note that the following actions are not allowed in fusion mode e Inverse video B amp W color palette NOTE When the orthogonal and mosaic views are both in the same mode fusion or not the window levels and color palette are set to be the same on both views The Projection view remains independent Codonics Infinity LX User s Manual 6 31 D 5 D 5 a no a Q o 6 32 L Window levels J SUV Scale s a 16 NOTE When changing the window levels on a fusion view only the functional image is updated To change the window levels on the anatomical image use the same mouse key combination and hold the ALT key down while moving the mouse Window Levels Options e Use the sliders to set the activity window
145. to exceed 187 F 86 C The system is shut down automatically to prevent damage to the CPU The CPU fan is not working The CPU fan is not working The system is in danger of overheating The system will continue to receive requests to store and retrieve studies but will shutdown automatically if the system exceeds the high temperature limit Email status notifications The SmartDrive has been removed are not being sent Solutions Remove any obstructions that prevent the free flow of air from entering the front and exiting the back of the chassis Replace the CPU fan For assistance contact Codonics Technical Support 1 440 243 1198 Make sure that users who are logged into the system from the Remote Desktop Connection application do not inadvertently shut down Infinity LX when they mean to shut down their local PC Remove any obstructions that prevent the free flow of air from entering the front and exiting the back of the chassis Replace the CPU fan For assistance contact Codonics Technical Support 1 440 243 1198 Replace the CPU fan For assistance contact Codonics Technical Support 1 440 243 1198 Make sure that the SmartDrive is inserted Codonics Infinity LX User s Manual 8 17 oo ph 48 os co os oo O gt o CR 5 Q o gt Q Table 8 5 Troubleshooting Continued Problem Power Possible Causes Solutions A power supply failed Infi
146. ton Refer to Cine Control on page 6 26 for an example of the full screen view Managing Studies Displaying Orthogonal Views F io To display on the free angle view click one of the three orthogonal L w view buttons Displaying the Clipping Box Clipping Box To display the clipping box click the Show button Show Reset The clipping box is displayed only on the orthogonal views Use these three views to isolate the region to view the result is displayed on the free angle view To clear the clipping click the Reset button Below is an example of clipping MPR MIP t g Y vu Ow Clipping Box Show Reset pasai K ap D 5 D 5 e 2 2 2 O Codonics Infinity LX User s Manual 6 25 Cine Control To access cine control click the MEI button The MIP Cine Control window displays x Start angle Increment fz fe 4 gt Zo o f views o FF E J gt The cine control has to be used like a table For the three axes of rotation specify a start angle The 34 button applies the angles specified With a Views value and Increment angles entered click the gt button to start a cine with Views frames each one separated by Increment angles IE m e gt The cine can be controlled with the Pause button Stop button or a Start Increase Cine Speed button There is also a Stop button in the MIP toolbar 6 26 Managing Studies Fusion Mode When sel
147. tus Information 8 9 Detailed Status in Information Panels cccccseceeeeeeeeteeeeneeereaes 8 10 Receiving Status via Email 8 12 Receiving Status via RSS ui 8 12 Receiving Infinity LX RSS Feeds in a Web Browser 8 12 Viewing RSS Status Information from Feedreader ccceeeee 8 13 Using the Feedreader Application 8 13 Troubleshooting Common Problems ccccccceeeeeeeeeeeeeeneeeseeeeeeeseeeesenees 8 15 Allowing Remote Access 8 21 System LOJE rs rat rene A a O teen A dean axe al 8 22 Codonics Infinity LX User s Manual vii viii Contents Appendix A Hazardous Material Information Materials of Construction A 1 Mat riaux de Construction ccccccccccccccceeceseesesseaseeseeeeeeessesssnsnaeeees A 2 Men uta Ctr ng PP na EE sty EEA A 3 Fabrication seirene neroni adaa onaco eeraa eee A 3 Appendix B Specifications Specifications English Sp cifications Fran ais cccccccccceseeeceeeeeeeneeeeeeeeeeeeeeseneeeeeeeesecneeeeeeeeene B 3 Preface Conventions Used in This Manual Bulleted Lists Bullets are used to display a list of nonprocedural items For example This chapter includes information you will need to set up Infinity LX s software e Setting up user accounts e Setting the system date and time e Setting up access for DICOM stations Numbered Steps The TS icon indicates the beginning of a procedure The steps in a procedure are num
148. ty LX e Do not place device in a high humidity or high dust area Airborne dirt particles can cause interference with the operation of the device Avoid placing the device in areas where ventilation ducts open doors or frequent passers by might expose the device and media to high levels of debris e Do not locate the device in hot springs areas where hydrogen sulfide and acidic ions are likely to be generated e Do not locate the device where there are oily fumes and vapors e Do not locate the device in direct sunlight e Do not locate device near sources of high RF energy high magnetic fields or ionizing radiation Environnement de Fonctionnement Infinity LX p se plus de 90 lbs 40 kg y compris les disques dur Il est important d exercer prudence en d placant la machine e Les conditions normales d utilisation de Vappareil sont une temp rature de 15 30 C 59 86 F et une humidit relative de 20 a 80 e En cas de variation rapide de la temp rature de la condensation peut se former Dans ce cas n utilisez pas l appareil attendez que la condensation se soit vapor e Vous pouvez acc l re cette vaporation en d placent l appareil dans un endroit sec e Les fentes de ventilation se trouvent lavant et l arri re de l appareil Placez l appareil sur une surface stable et au moins 10 cm 4 in des murs pour assurer une ventilation correcte l appareil ATTENTION Une ventilation
149. urn the keyboard s Caps Lock off and reenter the password Wait for the jobs to complete Check the system status indications Set the PDU size to the maximum of 128 KB on the Query Retrieve client and Store client Click the Options button in the Remote Desktop Connection dialog box On the Display tab open the Color list and click True Color 24bit Make sure that the user is searching in their local Windows file system and not from the remote desktop Contact Codonics Technical Support 1 440 243 1198 From a Remote Desktop Connection make sure that all applications are closed Try shutting down Infinity LX again If the problem persists contact Codonics Technical Support 1 440 243 1198 Table 8 5 Troubleshooting Continued Problem Temperature alert condition Infinity LX shuts down unexpectedly CPU fan fault condition Possible Causes There is an obstruction preventing the flow of air through the chassis causing the CPU temperature to exceed 176 F 80 C The system is in danger of overheating The system will continue to receive requests to store and retrieve studies but will shutdown automatically if the system exceeds the high temperature limit The CPU fan is not working Someone has inadvertently shut down Infinity LX from the Remote Desktop Connection application There is an obstruction preventing the flow of air through the chassis causing the CPU temperature

Download Pdf Manuals

image

Related Search

Related Contents

ABUS FU7350B  SCOTT MDX i65  coritrait` multi usages pe - Comptoir des produits bois  Metra 70-8112 power cable  DV589H- manual usuario  Port Designs Manhattan Toploading BF 10/13"  Uniden JIS7 User's Manual  HP W2012 User's Manual  取扱説明書 - アイ・オー・データ機器  Pâte à chichis  

Copyright © All rights reserved.
Failed to retrieve file