1. A Higher Level of Performance User Manual MiniWave Ultrasonic Level Series gt Liquid Level Measurement For more information please visit gt www hawkmeasure com Table Of Contents MiniWave User Manual Contents Overview 3 HART 9 Overview 3 HART Universal a Common Practice command list 9 Principle of Operation 3 Model Type 3 Troubleshooting 10 Dimensions amp Wiring 4 Unit is displaying incorrect distance 10 eere teens eee eeeeceeeeeeeueeseeueseeeu esse ene ect eas Analogue trend is erratic unstable 40 Dimensions 4 Unit is locked up or flat line measurement 10 Flange 4 Me PLC indication does not match measurement 10 Wiring 4 AutoSet fails 10 Installation 5 Se ee ee ee ee ee ere Roa Model Types Part Numbers 11 Mounting Be eee ete cic wre as ow rial smn eie Slee ia oo wie a O in ee aie Model Type 11 Powering The Unit 6 Accessories 11 Interface 6 Commissioning Software 7 Specifications 12 Startup 7 Main Menu if Setup 7 AutoSet T Advanced Settings 8 Overview MiniWave User Manual Overview MiniWave is a compact loop powered ultrasonic level transmitter for continuous measurement of liquids As a price leader it does not compromise on good value and provides effortless and intuitive operation Easy and flexible mounting combined with high chemical compatibility and 8 metre measuring range makes the MiniWave suitable in multiple applications in all industries Principle of Operation
2. The MiniWave emits an ultrasonic pulse which is reflected from the surface of the liquid being measured The reflected signal is processed using specially developed software to enhance the correct signal and reject false echoes Automatic sensitivity control allows the unit to dynamically adjust and improve the received echoes for the best possible measurement outcome Model Type MWN1A MiniWave with 2 NPT thread MWB1A MiniWave with 2 BSP thread E A Removable lid with viewing window B Electronics housing C M20 cable gland D NPT or BSP thread E Transducer face Sor a e HAWK Dimensions amp Wiring MiniWave User Manual Dimensions Wiring 85mm 3 4 Flip Lid to access terminals 185 mm 7 3 2 BSP or NPT THD M20 Blank Plug Flange FA2NB 4 2 ANSI Polypropylene Flange for NPT threaded units FA2BB 4 2 ANSI Polypropylene Flange for BSP threaded units 4 x 19mm 0 75 HOLES THROUGH 120mm 4 7 P C D ae 2 NPT or BSP INTERNAL THREAD 152mm 6 0 15mm 0 60 Installation MiniWave User Manual Mounting e Sensor should be mounted 1 3 the diameter of the 2 NPT MWN1A vessel from the vessel wall or 2 BSP MWB1A e Unit should never be closer than 250mm 10 to the liquid surface e Do not mount over or near objects which can interfere min 250mm 10 with the unit measu
3. different involving a multitude of oo a Support Team to assist with commissioning and environmental factors This is where HAWK excels a after sales service of HAWK equipment worldwide Our aim is to ensure that customers not only feel Measurement problems are addressed as they comfortable with our technology but that we also to 4 happen not days or weeks later ensure a consistent and reliable solution is in place for the long term We believe that a combination of application and product expertise as well as Knowledge Sharing forward thinking and proactive support policies HAWK believes that knowledge sharing is key to are the foundation of successful customer supplier creating long term relationships Empowering our relationships customers and our worldwide distribution network whilst being available at all times to lend a helping Progressive Technical Support hand is the perfect recipe for long term solutions and relationships HAWK openly extends an invitation to HAWK believes that the future of the Level l share our 25 years of level measurement experience Measurement Industry revolves around the quality 1 and ensure that your day to day processes are of pre and post sales support Our aim is for all efficient understood and always working sales amp support staff to be product experts and more All company or product names are registered trademarks or trademarks of their respective owners Hawk
4. 20 4mA 4 20mA Tune 4mA nalo and fine tune both 4mA current and 20mA current 20 4mA Tune 20mA Increase or decrease the unit s sensitivity to echoes eee The unit uses dynamic amp automatic sensitivity control 0 lowest default ensitivi 7 This parameter is a uniform adjustment to the overall unit 20 highest sensitivity Reset Restore all parameters to factory default Enable Disable lock code Enable Disable Lock Code 1 200 If enabled select lock code number Default Disabled HART MiniWave User Manual HART Universal Common Practice command list The MiniWave supports the following Universal and Common commands 0 Read unique identifier 1 Read Primary Variable 2 Read current and percent of range 3 Read current and four predefined dynamic variables 6 Write polling addr T7 Read loop configuration 8 Read Dynamic Variable Classifications 11 Read unique ident associated with tag 12 Read message 13 Read message 14 Read PV sensor information 15 Read output information 16 Read final assembly number 17 Write message 18 Write tag descriptor date 19 Write final assembly number 20 Read Long Tag 34 Write damping value 35 Write range values 44 Enter exit fixed current mode 57 Read unit tag descriptor date 58 Write unit tag descriptor date 59 Write number of response preambles 109 Burst mode control 110 Read all dynamic
5. Blanking Distance e 250 mm 10 Maximum Range e 12 metres 40ft Resolution e 1mm 0 04 Electronic Accuracy e 0 25 of maximum range Operating Temperature e 40 C to 60 C Maximum Operating Pressure e 0 5 to 3 bar 0 44 PSI Beam Angle e 7 Materials e Transducer PVDF e Housing Powder coated aluminum Display e 4 line graphic display 128 x 64 Keypad e 4 keys CAL RUN UP DOWN Memory e gt 10 years data retention Enclosure Sealing e IP67 Cable Entries e M20 cable glands Mounting e 2 BSP Thread e 2 NPT Thread Typical Weight 1kg 2 2 pounds Contact MiniWave User Manual HAWK Since 1988 importantly application experts making our customers applications as efficient and consistent as possible Hawk Measurement Systems Pty Ltd HAWK was established in 1988 It s founding members saw the Remote Innovation universal requirement of various industries requiring improved process control and efficiency in their HAWK understands the need for immediate technical operations assistance The HawkLink 3G communication device allows We Can Help any computer with internet access and our free rare GosHawk diagnostic amp calibration software to dial in HAWK understands the difficulties customers face i calibrate test and check the performance of HAWK when seeking accurate level measurement Every o a products This innovative system allows our Global lt application is
6. Connect a Multimeter in series with the powered loop Compare the mA diagnostic on the display with the mA reading on the loop If these values do not match disconnect the loop wires and measure the resistance across the loop This should not exceed specification See graph below Confirm High Level and Low Level are set to the same values in MiniWave and control system MiniWave Load Pulse Rate Vs Terminal Voltage Se ee re ese po a ee Pee A imn AutoSet fails e Increase Sensitivity to a higher value e Allow the unit to run for a longer time one minute Re attempt the Autoset e Set High and Low level manually in Setup menu If problems persist install replacement MiniWave in the application Bench test the problem unit in a controlled environment Model Types Part Numbers MiniWave User Manual Model Type MWN1A MiniWave with 2 NPT thread MWB1A MiniWave with 2 BSP thread Accessories FA2NB 4 2 ANSI Polypropylene Flange for NPT threaded units FA2BB 4 2 ANSI Polypropylene Flange for BSP threaded units Specifications MiniWave User Manual Frequency e 50 kHz Operating Voltage e 7 28VDC at the terminal residual ripple no greater than 100mV Power Consumption e 500mW 24VDC Analog Output e 4 20mA modulating output module with HART Recommended 250 Ohm 24VDC Analog Resolution e 14 bits Communications e 4 20mA with HART
7. Measurement Systems Hawk Measurement Head Office 7 River Street 15 17 Maurice Court Middleton MA 01949 USA Nunawading VIC 3131 AUSTRALIA Phone 1 888 HAWKLEVEL 1 888 429 5538 Phone 61 3 9873 4750 Phone 1 978 304 3000 Ke Fax 61 3 9873 4538 Fax 1 978 304 1462 info hawk com au info hawkmeasure com z O Q For more information and global representatives www hawkmeasure com E oO
8. rement e Do not mount in the centre of a curved roof to avoid the potential of parabolic echoes Installation MiniWave User Manual Powering The Unit When power is applied the unit will start up automatically It will scroll through its boot diagnostics and display the serial numbers software version and model types for the amplifier and transducer The selected Display Mode will be visible with a measurement The top right hand corner diagnostic indicates either the operating mode or the current output The unit will re scan for the level whenever it is powered up Display Mode Diagnostic Interface Press and release Access Main Menu Select Proceed Press and hold for 3 seconds Access Autoset Menu Press and release Cancel Return Re activate unit Press and Release Scroll between live diagnostics Scroll between menu options Adjust parameters Commissioning Software MiniWave User Manual Startup The MiniWave uses automatic sensitivity control to detect and maintain the level After applying power to the unit allow 20 30 seconds for the unit to adjust to the application Main Menu To access the Main menu press CAL To access AutoSet menu press and hold caL for 3 seconds Setup Parameter Description For best results ensure there is a liquid level present in the application or flat surface below the transducer Options Au
9. toSet Display Mode Set LCD measurement display mode Level Level Space Display Unit Adjust displayed measurement unit CenMetre Metres Feet Inches Low Level Set Low level measurement point 4mA Adjustable High Level Set High level measurement point 20mA Adjustable Damping Adjust output response time amp smoothness Adjustable in seconds 3 50mMA 3 80mA 20 20mA LstKnown 4mA 20mA LastKnown Failsafe Set failsafe output Use AutoSet to scan and program the unit High or Low level to the distance detected After the scan you will be prompted to accept the distance measured The High and Low level can also be manually adjusted in Setup ie _ HAWK Commissioning Software MiniWave User Manual Advanced Settings Device ID BaudRate CommtType Adjust HART protocol settings Default 1 1200 The unit will target this echo size measured in signal voltage during operation High values can increase 7 0 4 2 49V EchoSize stability but make the unit more susceptible to false 7 Default 0 59V echoes Lower values can make the unit less sensitive and less likely to see false echoes Adjust tracking response time for application The faster Slow the tracking the more responsive the measurement is Medium ieenag but it is less smooth the output signal Fast InstaTrack provides pulse by pulse live measurement InstaTrack Anal Adjust Analog output Switch from 4 20mA to
10. variables Troubleshooting MiniWave User Manual Unit is displaying incorrect distance e Confirm display mode is suitable Space is measured from Sensor face to measured level Material is measured from Low Level to measured level e Adjust sensitivity If unit is measuring too deep increase Sensitivity If unit is measuring too high reduce Sensitivity e Check if material is present to be measured Unit will output and display FailSafe reading if it cannot detect a level within range Analogue trend is erratic unstable e Increase Damping value for smoother trends e Choose a slower Tracking speed e Check there are no objects interfering with the transit pulse in the application Such as ladders and cross beams Unit is locked up or flat line measurement e Confirm there is material within measurement range the unit may go to Failsafe if there is no flat level available e If the unit is locked higher than the real level check for objects interfering with the transit pulse in the application such as ladders and cross beams Lower the Sensitivity Re locate the installation to avoid the interfering object e If the unit is locked lower than the real level confirm the application is not within Blanking distance Increase Sensitivity until unit measures correct level e Tracking speed may be too slow for the application Increase Tracking speed PLC indication does not match measurement e
Download Pdf Manuals
Related Search
MiniWave miniwave miniwave experience miniwave hunter douglas miniwave precio miniwave facebook miniwave infinity miniwave ultrasonic level transmitter miniwave experience facebook
Related Contents
ESEP User Manual Flow Control Type SWDS この報告書をダウンロードする StudioMaxIII Manual rev 5 Samsung Multifunktion Monolaser SCX-4623F Bruksanvisning Spin Master Wiggles Musical Plush User's Manual Guida Mercato Nord-Americano SK60 user manual - Warning Will Robinson FRS-110 FET Relay Switch 取扱説明書 User`s Manual 3 - schulerdenis.name Copyright © All rights reserved.