1. Calibration Display division value in different weight unit that can be used division value kg g Ib oz Ib 0z 0 00011b Not available Not available 0 00011b 0 0020z Not available 0 001 Ib 0 0005 kg 0 5g 0 001 Ib 0 020z Not available 0 01 Ib 0 005 kg 5g 0 01 Ib 0 20z 0 2 oz 0 1 Ib 0 05 kg 50g 0 1 Ib 20z 2 oz 1 Ib 0 5 kg 500g 1 Ib 200z Not available 10 Ib 5kg Not available 10 Ib Not available Not available 0 0002 Ib 0 0001 kg 0 1g 0 0002 Ib 0 005 oz Not available 0 002 Ib 0 001 kg 1g 0 002 Ib 0 05 oz Not available 0 02 Ib 0 01 kg 10g 0 02 Ib 0 5 oz 0 5 oz 0 2 Ib 0 1 kg 100g 0 2 Ib 5 oz Not available 21b 1 kg Not available 2 Ib 50 oz Not available 20 Ib 10 kg Not available 20 Ib Not available Not available 0 0005 Ib 0 0002 kg 0 2g 0 0005 Ib 0 01 oz Not available 0 005 Ib 0 002 kg 2g 0 005 Ib 0 1 oz 0 1 oz 0 05 Ib 0 02 kg 20g 0 05 Ib 1 oz 1 oz 0 5 Ib 0 2 kg 200g 0 5 Ib 10 oz Not available SIb 2 Kg Not available 5 Ib Not available Not available 50 Ib 20 kg Not available 50 Ib Not available Not available KILOTECH INC www kilotech com 23 5 13 Check Weight in weighing mode 5 13 1 To make weight compare function be available CONFIG FUNC COMPAR item should set to YES and high and low limitation of weight should be set correctly according to following steps 5 13 2 In weighing mode Press down DATA key more than 3s to input compare data of high and low 5 13 3
2. HPCEUL GE n Yes No enable disable output weight of 1 a f na percentage Prompt is 1 REF WT Palit ae o Yes No enable disable output counts Prompt is LOUII To Wo QUANTITY PEUL LE n Yes No enable disable output piece weight Prompt is E To 110 PIECE WT e JES n Yes No enable disable output height and BMI Prompt me To Se is HEIGHT and BMI ACL AL JE5 n Yes No enable disable output accumulation times and ou Ha DE total Prompt is ACC N and TOTAL YES m D D Di Aner fo Yes No enable disable output date Prompt is DATE 110 YES n D H a Di ef amie WS Yes No enable disable output time Prompt is TIME HD EISE Yes No enable disable output ADC s code P ti r n pu s code Prompt is Hd odE Po 110 A D CODE bA Gol LE n Yes No enable disable output voltage of battery HES No ges Prompt is VOLTAGE LEREL LE n Yes No enable disable output scale s status Prompt is LI a 110 STATUS IIO Mole LINE How many blank lines after strings output NONE no blank line mn m gi H BL fE Liflec Lille LINE1 2 3 4 there re 1 2 3 or 4 blank lines after strings L REJ used for paper feed forward 1 2 3 4 lines L NEH ieoi CALE 4800 bAUd r E JENA 9600 selection of com2 s baud rate UL 9200 38400 e LO Ac an r ZA selection of com1 s byte format Ge 1 8N1 8 data bits No parity check bit 1 stop bit 3F ny 2 701 7 data bits 1 Odd
3. PIN DEFINITION IN OUT POWER ELECTRICAL LEVEL 1 RS485 signal A if RS485 installed Input output 0 5Vdc 2 RS232 Transmit on COM1 Output 12 to 12Vdc 3 RS232 Receive on COM1 Input 12 to 12Vdc 4 5 GND Power ground OVdc 6 7 8 9 RS485 signal B if RS485 installed Input output 0 5Vdc 25 6 J1 USB Connector for virtual RS232 1 and USB power supply PIN DEFINITION IN OUT POWER ELECTRICAL LEVEL 1 VDD Power output 5 0 3 Vdc 2 RXD Receive on COM2 Input 0 5Vdc 3 TXD Transmit on COM2 Output 0 5Vdc 4 GND of VDD Power ground OVdc 5 GND1 of VUSBH Power ground OVdc 6 USB Power DC DC select Output 0 5Vdc 7 USB Power DC DC output output 60 3 Vdc 25 7 KCAK Jumper set CONNECTED PINS FUNCTION 1 2 Calibration Disabled 2 3 Calibration Enabled 25 8 JP1 Jumper CONNECTED PINS FUNCTION 1 2 Two shorter on pin1 2 4 wires Load cell is used 2 3 Two shorter on pin2 3 6 wires load cell is used 25 8 ICM1 Socket used for optional Bluetooth RS485 or USB interface 25 9 JTAG and IOSEL used by Manufacture KILOTECH INC www kilotech com 45 25 Meaning of Some Symbols and Troubleshooting 25 1 Meaning of Symbols 25 1 1 QO 8 Zero is over the setting range 25 1 2 0 Zero point is below the setting range 25 1 3 Ad Signal to ADC is over max range 25 1 4 A0 Signal to ADC is below min range 25 1 5 7 Weight is over upper limitation or display data is over limitation
4. Bit Status Byte1 Status Byte2 0 0 Scale in motion 1 Under capacity 1 Stable 0 Not under capacity 1 0 Scale at zero 1 Over capacity 1 Not at zero 0 Not over capacity 2 O RAM error 1 ROM error 1 RAM okay 0 ROM okay 3 0 EEPROM error 1 Faulty calibration 1 EEPROM okay 0 Calibration okay 4 Always 1 Always 1 5 always 1 always 1 6 always 0 always 0 7 parity parity 23 9 3 Key to symbols used lt ETX gt End of TeXt character 03 hexadecimal lt LF gt Line Feed character OA hex lt CR gt Carriage Return character OD hex Xxxxxx Weight characters from display including minus sign and out of range characters p Polarity character ie for negative space for positive hh Two status bytes see 23 9 2 UU Units of measure LB KG or OZ all upper case 23 9 4 Summary of Command and Response Command Response ASCII HEX Returns decimal lb kg or oz weight units and status lt LF gt pxxx xxUU lt CR gt hh lt ETX gt Returns ounces weight with units plus scale status W lt CR gt 57 0D lt LF gt p00xxxxxOZ lt CR gt hh lt ETX gt Scale status only if initial zero error lt LF gt hh lt CR gt lt ETX gt S lt CR gt 53 OD Read scale status lt LF gt hh lt CR gt lt ETX gt Z lt CR gt 5A OD Simulate ZERO key no response from scale others Un known commands lt LF gt lt CR gt 23 9 5 If your indicator need work with UPS worldship you can tr
5. 12 8 After the indicator gets all need data it will calculate and store all calibration parameters into EEPROM or after finishing calibration works it will display CAL End At last it will re start and go back to original mode KILOTECH INC www kilotech com 32 Location Code for different elevation and latitude TABLE12 1 co LS Ls ES ENEE efi 2 TIn BREBRBE KILOTECH INC www kilotech com 33 13 Weight Fine tune With this function the user can adjust displayed weight a little and no need standard weight But please Note 1 The scale must have been calibrated before this adjustment 2 The range of adjustment is current displayed weight x 0 9 1 1 it means the range is about 10 3 The CONFIG REGULA NONE and CONFIG FUNC WT ADJ YES must be set 4 Only an authorized manufacturer s representative or certified verification personnel may make these changes Changing this value alters the calibration values UI 13 1 To enter this mode turn on indicator after indicator displaying O weight put a load suppose its correct weight is 1230 0lb onto scale then indicator will display the load s weight say 1234 5 Ib Press down TARE and ZERO at same time until first digit flashes this means indicator has entered into weight fine tune mode 13 2 Use if d to input correct weight 1230 0 After confirmed by TARE the active correct weight will be displayed and no any
6. LACE SES S Yes No enable disable output tare weight Prompt is CT ie 10 TARE NEE SES YES Yes No enable disable output net weight Prompt is II eg NET PE CNE JE5 o Yes No enable disable output weight percentage degt fo te Prompt is PERCENTAGE PEE UE ne e Yes No enable disable output weight of 1 sous fs Se percentage Prompt is 1 REF WT Count S n Yes No enable disable output counts Prompt is LOUII To 110 QUANTITY put E Yes No enable disable output piece weight Prompt is LE ie 110 PIECE WT ES YES e Yes No enable disable output height and BMI Prompt SZ Ba Ge is HEIGHT and BMI ACCU AL JE5 n Yes No enable disable output accumulation times and E ES total Prompt is ACC N and TOTAL 110 YES n D D 12 dAEE fo Yes No enable disable output date Prompt is DATE 110 _ YES n D H a Di E nE Mo Yes No enable disable output time Prompt is TIME HO SES Yes No enable disable output ADC s code Prompt i A pu s code Prompt is Hd odE es 110 A D CODE KILOTECH INC www kilotech com 14 EN JE5 A Yes No enable disable output voltage of battery BH wae Ilo No Prompt is VOLTAGE SEALL E5 n Yes No enable disable output scale s status Prompt is To Ges STATUS MoftE LINE How many blank lines after strings output NONE n0 blank line m mM D
7. 5 12 Change Weight UNIT Short press UNIT key to select kg Ib Ib oz g or oz unit note under some condition g and Ib oz is not available And In trade application Ib oz should be prohibited Please refer the following tables KILOTECH INC www kilotech com 22 Table5 2 use Kg as primary unit Calibration Display division value in different weight unit that can be used division value kg g Ib oz Ib 0z 0 0001kg 0 0001kg 0 1g 0 00021b 0 0050z Not available 0 001kg 0 001kg 1g 0 002Ib 0 050z Not available 0 01kg 0 01kg 10g 0 02Ib 0 50z 0 50z 0 1kg 0 1kg 100g 0 2Ib Doz Not available 1kg 1kg Not available 2lb 500z Not available 10kg 10kg Not available 20 Ib Not available Not available 0 0002kg 0 0002kg 0 2g 0 0005 Ib 0 010z Not available 0 002kg 0 002kg 2g 0 005 Ib 0 10z 0 1 oz 0 02kg 0 02kg 20g 0 05 Ib 10z 1 oz 0 2kg 0 2kg 200g 0 5 Ib 100z Not available 2kg 2kg Not available 5 lb Not available Not available 20kg 20kg Not available 50 Ib Not available Not available 0 0005kg 0 0005kg 0 5g 0 001 Ib 0 020z Not available 0 005kg 0 005kg 5g 0 01 Ib 0 20z 0 2 oz 0 05kg 0 05kg 50g 0 1 Ib 20z 20Z 0 5kg 0 5kg 500g 1 Ib 200z Not available 5kg 5kg Not available 10 Ib Not available Not available 50kg 50kg Not available Not available Not available Not available Table5 3 use LB as primary unit
8. Response Zero function is activated simulate ZERO key and it returns to current scale status lt LF gt H4H2H3H4 lt CR gt lt ETX gt If ZERO function cannot be activated it will return to current scale status 23 6 1 4 Command T lt CR gt 54h Odh Response TARE function is activated simulate TARE key and then returns scale status lt LF gt H4H2H3 H4 lt CR gt lt ETX gt If TARE function cannot be activated it will return to current scale status KILOTECH INC www kilotech com 38 23 6 1 5 Command U lt CR gt 55h Odh Response Changes units of measure simulate UNIT key and return scale status with new units The new measure unit should be allowed to use lt LF gt U1U2 U3 U U5 lt CR gt lt LF gt H1H2H3 H4 lt CR gt lt ETX gt 23 6 1 6 Command L lt CR gt 4ch Odh Response If Hold function can be activated it will enable disable hold function simulate HOLD key and returns scale status lt LF gt H H2H3H4 lt CR gt lt ETX gt 23 6 1 7 Command X lt CR gt 58h Odh Response power off the scale just like press down the ON OFF key to turn off the scale 23 6 1 8 Command all others Response Unrecognized command lt LF gt lt CR gt lt ETX gt 23 6 2 Summary of Command and Response Command Response ASCII HEX Read scale weight D lt LF gt AMMMAUAU U3U4U5 lt CR gt lt LF gt H H2H3 Ha lt CR gt lt ETX gt over capacity lt LF gt U U U3U U5 lt CR gt lt LF gt H H2H3 Hy lt CR gt lt
9. 12 2 After entering this mode the number of this indicator has been calibrated will be shown first this number will be increased one after every calibration and calibration data saved and this counter can t be modified or erased by any other ways it counts from 0000 to 9999 when it reaches 9999 it starts over at 0000 After the counter number being displayed it will show CAL OFF or CAL ON according to the status of the sealed calibration switch is OFF or ON If the switch is OFF the following steps can be done but the result will not be saved Press TARE key to go to next step 12 3 When ZERO is shown use PRINT or ACC key to select do zero point calibration refer step12 4 do linearity calibration refer step12 5 do Geographical calibration refer step 12 6 or Input view calibration parameters value refer step 12 7 12 4 When ZERO is selected remove all weight on scale and then press TARE key to confirm the ZERO will flash when in catching zero point state After getting reasonable data it automatically goes to step12 8 12 5 When LINE is selected press TARE key to confirm to enter linearity calibration 12 5 1 12 5 2 12 5 3 12 5 4 12 5 5 12 5 6 0 weight will be displayed after CAL PO being shown remove all weight on scale and then press TARE to confirm to calibrate the zero point the zero weight will flash in catching zero point state After getting the reasonable zero point data th
10. 6 2 To make counting function be available CONFIG FUNC COUNT item should be set to YES in CONFIG menu 6 3 To enter counting working mode in normal weighing or percent weighing mode long press FUNC key WEIGH PERCEN will be shown use ACC or PRINT key to select COUNT then press TARE to confirm go to parts counting mode Before new piece weight is got the last piece weight will be used 6 4 In counting working mode the function of ZERO TARE PRINT HOLD PRESET TARE ACC SETUP ON OFF are available 6 5 There re two ways to obtain the piece weight 1 input piece weight directly refer operations of step6 5 1 2 weigh samples weight which quantity is known refer operation of step6 5 2 6 5 1 Input piece weight from keypad in counting mode press UNIT key When InP PWt is shown press TARE key to enter input piece weight mode KILOTECH INC www kilotech com 24 6 5 1 1 When UNIT KG is shown use PRINT or ACC key to select the unit of piece weight use TARE key to confirm and go to next Press ZERO key to exit getting piece weight mode and back to counting mode 6 5 1 2 When last stored piece weight is shown use PRINT ACC UNIT key to input new piece weight press SETUP key more than 3s to input decimal point Press TARE key to confirm and save it then go back to counting mode If the input piece weight is less than 0 5d the indicator will display PWt Er and go back to counting mode 6 5 2 Obtain piece weight by weighing samples w
11. KILOTECH KIN 500 Indicator Operation and setup Manual V4 12 Contents Subject to Change without Notice KILOTECH INC www kilotech com Missing Parts Pi ces manquantes Scale Not Calibrating Balance ne se calibre pas Need Help with Installation Besoin d aide pour l installation Before returning this product to your local retailer Avant de retourner ce produit au d taillant please contact Kilotech Customer Service at communiquez avec le service la client le de Kilotech au USA 1 877 328 5988 tats Unis 1 877 328 5988 Canada 1 800 694 4445 Canada 1 800 694 4445 Email kilotech kilotech com Courriel kilotech kilotech com Ce manuel est disponible en francais a www kilotech com ou aupr s de notre service la client le au 1 800 694 4445 KILOTECH INC www kilotech com CONTENT 1 Specification EE 2 R EI o Fe E EE E TEA TE E ATAT 6 3 Summary of Key function ns 7 5 Normal Weighing mode ns 21 6 Count Weighing Mode 24 7 Percent Weighing Mode 26 8 BMI Working Nels geegent eebeeeg 27 Claren OI 2 aanas aaasta aani 28 10 Data Compare Function vccccccisccstes cece cecctecccccanwencececcupecteaetdecccedecccaues 29 11 OT UD 30 12 ANI AIO cee eeteccatecta sens eeezcececeaasacedhadeachinseenaceestcnucerbacseoue 31 13 Weight Fine tune asec cts ete d
12. BL fE ale Lille LINE1 2 3 4 there re 1 2 3 or 4 blank lines after strings L REJ used for paper feed forward 1 2 3 4 lines Life ieii eYou Here Y800 9600 selection of com3 s baud rate 9600 13200 hi 7o selection of com1 s byte format 1 8N1 8 data bits No parity check bit 1 stop bit LUE TE on 2 701 7 data bits 1 Odd parity check bit 1 stop bit di LE 3 7E1 7 data bits 1 Even parity check bit 1 stop bit log 4 702 7 data bits 1 Odd parity check bit 2 stop bit 5 7E2 7 data bits 1 Even parity check bit 2 stop bit IEg MolE Select com3 output mode 8 Fone 1 NONE No communication Long LON 2 CONT continuously output Prif 3 PRINT output after PRINT key pressed HE Aod BEL Rd 4 CMD output after a request command is received RHEN Cid ELNO 5 PRT CMD output after PRINT key pressed or request command received PrELnd 6 STABLE output after scale is stable Note use PRINT or CMD to output data the scale must 5E AbLE be stable Gm l Com3 output content and format set AULEPL 1 MULTPL the following selected item in OUT3 will be output use defined format S ANGLE 2 SINGLE only displayed content and current status AYU HL EPI will be output it s compatible with NCI SCP01 eae MULET EL 3 EH SCP Command response mode similar to EH 5LP Toledo PS60 protocol 4 SCP 12 only displayed content and current status p e 73 will be output it s compatible with NCI SCP12 Ste NCI3835 ER
13. 100006 Operations refer to section 7 L SES Ro Yes No enable disable BMI function Operations refer EUNC l Tp k to section8 SE Yes No enable disable data comparison function TI D LonPHr To JE5 Operations refer to section 9 F Accumulation Mode selection QE 1 NO no accumulation function 2 MANUAL add up current number to accumulation memory after ACCUAU GANUAL nANUAL TATOL key is pressed 3 AUTO automatically add up current number to LE accumulation memory after scale is stable and weight or is over NLD RNG JES Yes No enable disable Geographical Adjustment rol m GEoLAL m n Me ifado YEG Yes No enable disable weight fine tuning using LE Ho Mo keypad in weighing mode NO if REGULAR none this item is NO The setting will be limited by choice of REGUALA KILOTECH INC www kilotech com 11 4 3 USER Submenu Sub Sub Menu Menu Option Default Remark m PERE SCH Ma reset user parameters to default setting edi 2400 7 4A SE bAUd r E DEDD 9600 selection of com1 s baud rate UU Feud 30400 HIT selection of com1 s byte format loi 1 8N1 8 data bits No parity check bit 1 stop bit ny 2 701 7 data bits 1 Odd parity check bit 1 stop bit BEF NE JET dl 3 7E1 7 data bits 1 Even parity check bit 1 stop bit log 4 702 7 data bits 1 Odd parity check bit 2 stop bit 5 7E2 7 data bits 1 Even
14. 34 56 A D CODE 1231234 VOLTAGE 6 7V STATUS bpq2 KILOTECH INC www kilotech com 41 23 8 Communication Details when USER COM1 2 LAYOUT is set to EH SCP 23 8 1 This protocol of serial communication is similar to TOLEDO PS60 protocol The baud rate and data format is set by User menu 23 8 2 Output status bit meaning Bit Status Byte 0 0 Stable weight data 1 Scale in motion 1 0 Within weighing range 1 Over capacity 2 0 Within weighing range 1 Under zero 3 0 Within range 1 Outside zero capture range 4 0 Not at center of zero 1 Center of zero 5 always 1 6 always 1 7 parity 23 8 3 Summary of Command and Response Command Response ASCII HEX Read scale weight normal data W 57 lt STX gt W4 W2 lt dp gt W3W4W lt CR gt if current weight is invalid lt STX gt lt Status Byte gt lt CR gt Simulate ZERO key Z 5a lt STX gt lt Status Byte gt lt CR gt L 4c Switch to and send standard weight Same as W above K 4b Switch to and send metric weight Same as W above Un known commands others lt STX gt lt Status Byte gt lt CR gt KILOTECH INC www kilotech com 42 23 9 Communication Details when USER COM1 2 LAYOUT is set to SCP 12 23 9 1 This protocol of serial communication is similar to with NCI3835 protocol The baud rate and data format is set by User menu 23 9 2 Output status bit meaning
15. O ROM ok O gross weight O not in HOLD 1 RAM error 1 ROM error 1 net weight 1 in HOLD 3 0 eeprom OK O calibration ok O initial zero ok O battery ok 1 eeprom error 1 calibration error 1 initial zero error 1 low battery 4 jalways 1 always 1 always 1 always 1 5 jalways 1 always 1 always 1 always 1 D jalways 0 always 1 always 1 always 0 7 parity Parity parity Parity 23 6 Communication Details when USER COM1 2 LAYOUT is set to SINGLE 23 6 1 Commands and response 23 6 1 1 Command W lt CR gt 57h Odh request current reading Response D lt LF gt MAMMMUU U3U4Us lt CR gt lt LF gt H1H2H3 H4 lt CR gt lt ETX gt over capacity s lt LF gt U U2 U3 UgU5s lt CR gt lt LF gt HHH Ha lt CR gt lt ETX gt under capacity lt LF gt U1U2 U3 U U5 lt CR gt lt LF gt HHH Hy lt CR gt lt ETX gt zero point error Note U U U3U Us5_ is 1 2 3 or 5 bytes according to current unit kg lb pcs Ib oz lt LF gt lt P gt W W 2W23W4W5 lt DP gt We U U2 U3 UszU5 lt CR gt lt LF gt H4H2H3 H4 lt CR gt lt ETX gt normal data Note 1 The decimal point position is determined by CONFIG PRIM D 2 If current unit is Ib oz the format will be similar with following lt LF gt lt P gt W W 2W lb lt SPsW 4W 5 lt DP gt W 0z lt CR gt lt LF gt HHH H4 lt CR gt lt ETX gt 23 6 1 2 Command S lt CR gt 53h Odh request current status Response lt LF gt H H2H3 H4 lt CR gt lt ETX gt 23 6 1 3 Command Z lt CR gt Gab Odh
16. digit will be flashed After this displayed weight will be adjusted by this ratio 1230 0 1234 5 and this ratio will keep active until next modification on it 13 3 To remove effect of this ratio there re two ways 12 3 1 way and 12 3 2 way 13 3 1 Do standard calibration like in 12 CALIBRATION 13 3 2 Move away weight on scale Press ZERO to make 0 displayed Put a load onto scale a number will be displayed suppose it s 1230 0Ib but original number is 1234 5 Press down TARE and ZERO at same time until first digit flashes this means indicator has entered into weight fine tune mode Press A key the displayed weight will be restored to 1234 5 and then press A JI to confirm and exit to normal weighing mode 14 View ADC output Code 14 1 In this mode you can examine the stability of weighing system the increment value of ADC output code corresponding to the loaded weight Note The increment of ADC code for FS weight must be larger or equal to 10 times of selected display division otherwise the calibration cannot be properly completed e g The display division is 0 1kg Load 100kg standard weight on the platform the increment of ADC code should be at least more than 10x100kg 0 1kg 10x1000 10000 In this case the scale can be calibrated Otherwise smaller division needs to be Chosen The variation of ADC code should be small otherwise the calibration cannot properly complete also 14 2 To go to this w
17. please note to use the second function of one key need pressing the key over 3 seconds To input data or select menu use lt e Ly to process 5 2 Power on scale when scale is off short press ON OFF key to turn on Power off scale when scale is on long press ON OFF key to turn off the scale 5 3 Change working mode long press FUNC key then weet pan to choose and confirm to enter into weighing mode counting mode or percentage working mode 5 4 Enter to or exit from HOLD mode press HOLD key 5 5 ZERO When the weights is stable and within the zero range press ZERO key to set new zero point Please refer the ZERO and TARE limitations in 5 9 section 5 6 TARE When the gross weight is big than zero and the scale is stable press TARE key the indicator will show net weight of zero the NET announciator will be lighted Please refer the ZERO and TARE limitations in 5 9 section 5 7 Preset tare weight long press PRESET key Pr Tare will show and the TARE announciator flashes it means it is in preset TARE weight mode use jj l l to input tare weight and its unit is same as the unit that it used before there s no limitation to preset tare weight but it should bigger than zero After input a tare weight NET announciator will be lighted Note this indicator can only save one tare weight the new tare weight will automatically replace the old one Also please refer the ZERO and TARE limitations in
18. the max is 10 000 100 AL o Fis Display weight at 10 times division number under e GER primary unit if REGULAR none no this item Check motion window oof voll ga H 1 255 0 25d 1 255 if REGULAR none the max is 12 over load display limitation 0 FS 9d TI IN m D ou rid re 1 100 101 FS 200 FS if REGULAR none the max is 10 E AdL Weight Data comes from AdFran e e Hd ADC local A D chip on PCB Lond COM3 COMS interface o Speed of A D convert HS NO 10Hz m 3 LE if AD FROM COMB3 this item will not be shown LG LE YES 110 L SES YES Units that can be used by UNIT key select m m S YES YES enable this unit to be used NO disable this unit HES me Mo to be used 110 ig Je GES e Refer to sectioon5 12 for some limitation In trade na To ZS application Ib oz should not be allowed JES im m U Oo Ao L Initial zero power on zero point range 0 no limitation ET O JOU iL 1 100 calibration zero point 1 FS calibration zero point 100 FS If REGULAR none the max is 10 YE LHE Choose which weight as current initial zero point when current weight is_in IZSM range WEIGHT m CL rai u r current weight Micon CALZro SE GE CAL ZRO calibration zero LAST Z T switch off Dn zero and tare SP ZS LASEZE If REGULAR none the setting is WEIGHT d9P our Choose which weight as current initial zero point when current weight is over IZSM range YE GHE DSP OVR display initial zero is over WEIGHT ou Sn dbPo
19. 1 7E2 702 1 7 5 Protocol programmable KILOTECH INC www kilotech com 4 1 8 Analog Circuit characters 1 8 1 24 bit A D converter 1 8 2 Conversion Speed 10Hz or 80Hz selectable 1 8 3 Input range 15mV to 15mV 1 8 4 Output code 1mV input between S and S of load cell connector will output about 100 000 raw Counts 1 8 5 With Hardware low pass filter and two programmable digital low pass filters 1 9 Accuracy lt 0 01 1 10 Capacity and Division Programmable 1 10 1 Max display range 999 999 to 999 999 1 10 2 Division number range for primary unit 100 100 000 Division number range for second unit 100 125 000 Division number will be limited by REGULA setting 1 10 3 Recommended Sensitivity gt 1uV display division 1 11 Calibration Method 1 11 1 Software calibration with long term storage in EEPROM 1 11 2 Provides smooth curve fit through four points 1 11 3 Calibration can be done under kg or Ib weight unit with 10 100 FS standard weight 1 11 4 Optional directly weight fine adjustment 10 1 11 5 Optional Geographical Adjustment 1 12 Real Clock optional built in nonvolatile real time amp date 1 13 Other Main Function 1 13 1 Programmable Initial or key Zero Range automatic zero point tracking range 1 13 2 Programmable pre set tare weight 1 13 3 Programmable motion detection window 1 13 4 Programmable auto power off time backlight working mode 1 13 5 Programmable hold function with peak weight holding dyn
20. 25 1 6 _ Weight is below lower limitation 25 1 7 EEP E1 CONFIG or CAL parameters are not correctly set 25 1 8 EEP E2 USER parameter is not correctly set 25 1 9 Lo bAt Battery voltage is lower than setting 25 1 10 CAP Next displaying content is Capacity 25 1 11 CAPER Parameters about Capacity is not correct 25 1 12 CAL Px Calibration on point x 25 1 13 CAL OFF Calibration Seal Switch is on OFF position 25 1 14 CAL ON Calibration Seal Switch is on ON position 25 1 15 CAL Er Calibration error maybe input data or loaded weight is incorrect unstable un linear 25 1 16 CAL End Calibration is end 25 1 17 OFF Power OFF the indicator 25 1 18 STB ER Unstable time is lager than setting of USER HOLD STB TIM 25 1 19 AC xxxx Accumulation times is xxxx 25 1 20 PR TARE To Preset TARE weight 25 1 21 COMP To go to input COMPARE data mode 25 1 22 HGH To input HIGH limitation data of Comparison 25 1 23 LOW To input LOW limitation data of Comparison 25 1 24 SPL Lo Sample load weight of low point 25 1 25 SPL HI Sample load weight of high point 25 1 26 SPL PWT Sample goods weight to calculate piece weight 25 1 27 INP PCS input pieces number of weighted goods 25 1 28 UNIT KG Unit kg is selected 25 1 29 UNIT LB Unit Ib is selected 25 1 30 PWT ER Piece weight is error it s too small l
21. 5 9 section 5 8 Clear tare weight remove any weight on platform wait till the scale is stable short press TARE key please refer the ZERO and TARE limitations in 5 9section KILOTECH INC www kilotech com 21 5 9 Limitation to ZERO and TARE operation under different conditions Table5 1 Weight j key function Standard on paie platform y Tare key Zero key no No action lt 0 yes Clear the tared weight USA T Zero o gt 0 Tare Yes no No action lt 0 Yes Clear the tared weight Canada Zero No Tare gt 0 Yes No action No No action Zero lt 0 Yes Clear the tared weight zero ann clear the Europe tared weight No zero 70 SN Tare zero and clear the tared weight No No action Zero lt 0 None yes Clear the tared weight a clear ihe same with tared weight Europe No zero 70 S Tare zero and clear the y tared weight NOTE 1 ZERO only be active when scale is stable and weight is in SAZSM setting range 2 3 mge j ie ei TARE only be active when scale is stable 4 TARE weight make indicator to enter displaying NET mode 5 10 Output data When scale is stable press PRINT key 5 11 Accumulation Clear TARE weight or ZERO scale make indicator to enter displaying GROSS mode Press ACC key to add displayed number to accumulation memories and accumulation times will also add up 1 and then to display accumulation result
22. After HIGH being shown 000000 will be displayed use PRINT ACC UNIT key to input high weight number and press TARE key to confirm Announciator of Hi will be shown in this step Press ZERO key to exit and back to weighing mode 5 13 4 After Low being shown 000000 will be displayed use PRINT ACC UNIT key to input low weight number and press TARE key to confirm Announciator of Lo will be shown in this step Press ZERO key to exit and back to weighing mode NOTE If High number is 0 or is equal or less than low number the comparison will be disabled and the input data has no limitation 5 13 5 After a reasonable limitation is set and compare is be active one of announciators HI OK LO will be lighted and the beeper will sound according to its setting in USER BEEP 5 14 Enter Setup Mode 5 14 1 If need to set configuration parameters set user parameters calibrate the scale set current date or time test some hardware Its need to long press SETUP key to enter setup mode 5 14 2 After Entering Setup Mode the main menu item CONFIG will be shown first 5 14 3 In Setup mode use 4 ae e L to select wanted submenu and wanted menu item select wanted choice set wanted number confirm and save data or exit this mode Please refer the 4 Operation Menu Structure 6 Count Weighing Mode 6 1 In this mode scale will weigh goods weight on scale calculate and display its counts after the piece weight of goods is obtained
23. C UNIT key to input new number of low and press TARE key to confirm Announciator of Lo will be shown in this step Press ZERO key to exit and back to original working mode NOTE f High number is 0 or is equal or less than low number the comparison will be disabled 10 6 After a reasonable limitation is set and compare function is be active one of announciators HI OK LO will be lighted and the beeper will sound according to its setting in USER BEEP 10 7 For details please refer to section of section5 13 6 6 and 7 6 11 Accumulation 11 1 Accumulation function can be used in normal weighing mode counting mode and percent weighing mode When this function is enabled you can accumulate current net weight piece and percentage Note only the load on scale is larger than USER OTHER NLD RNG the displayed positive number can be added up The accumulation times and total can be displayed or printed 11 2 To make data accumulation function be available CONFIG FUNC ACCUMU menu item should set to MANUAL or AUTO Following are details 11 3 When CONFIG FUNC ACCUMU is set to MANUAL the stable and positive displayed net weight must be larger than USER OTHER NLD RNG piece or percentage can be accumulated by long pressing TOTAL key and indicator will display accumulation times first and then display total of number To avoid repeating accumulation for same load one load only can be accumulated once So before a new load put onto the scale
24. ETX gt under capacity W lt CR gt 570d lt LF gt UU U3 U4U5 lt CR gt lt LF gt H H2H3 Hy lt CR gt lt ETX gt zero point error lt LF gt lt p gt W W 2W3W Ws lt dp gt W U U2U3U Us lt CR gt lt LF gt H H2H3H4 lt CR gt lt ETX gt normal data S lt CR gt 530d lt LF gt H H H3H lt CR gt lt ETX gt read scale status Z lt CR gt 5a 0d lt LF gt H H2H3H4 lt CR gt lt ETX gt simulate ZERO key T lt CR gt 540d lt LF gt H H2H3H4 lt CR gt lt ETX gt simulate TARE key U lt CR gt 55 0d lt LF gt U U2 U3 U4U5 lt CR gt lt LF gt H H2H3H4 lt CR gt lt ETX gt simulate UNIT key L lt CR gt 4c 0d lt LF gt H H2H3H4 lt CR gt lt ETX gt simulate HOLD key X lt CR gt 58 Od power off the scale simulate OFF key others lt LF gt lt CR gt lt ETX gt KILOTECH INC www kilotech com 39 23 7 Communication Details when USER COM1 2 LAYOUT is set to MULTIPLE 23 7 1 Output string frame lt LF gt lt Prompt gt lt p gt W W 2W3W 4Ws lt Dp gt Wg U1U2 U3 U4U5 lt CR gt Line number and content are determined by setting of USER OUT1 2 xxxx lt LF gt lt Prompt gt H H2H3 H4 lt CR gt USER OUT1 2 STATUS is set to YES 1 The decimal point position is determined by CONFIG PRIM D 2 The unit position and bytes is determined by which current unit is used 3 The details of lt Prompt gt refer to the content in 4 3USER Submenu 4 In hold mode if ADC conversi
25. JES n Yes No enable disable output scale s ID number Ee me Prompt is SCALE ID out IB 2 G ob5 JE z Yes No enable disable output gross weight Prompt is ro To HB GROSS KILOTECH INC www kilotech com 15 YE5 Yes No enable disable output tare weight Prompt is m LATE No 110 TARE NEL GES YEG Yes No enable disable output net weight Prompt is Il eg NET PE CNE HES A Yes No enable disable output weight percentage me Mo ng Prompt is PERCENTAGE DCL ut HES Si Yes No enable disable output weight of 1 on To Gg percentage Prompt is 1 REF WT PRE SE o Yes No enable disable output counts Prompt is LOUII No 110 QUANTITY Prue JE5 n Yes No enable disable output piece weight Prompt is L Fie 110 PIECE WT ES JE5 n Yes No enable disable output height and BMI Prompt a fo a is HEIGHT and BMI EE JE5 m Yes No enable disable output accumulation times and For fo e total Prompt is ACC N and TOTAL HES dAEE No lo Yes No enable disable output date Prompt is DATE Eine JE 3 fo Yes No enable disable output time Prompt is TIME fa 4ES Yes No enable disable output ADC s code Prompt is T mn Hd odE A 110 A D CODE 110 bAk ool SE A Yes No enable disable output voltage of battery gaa flo Ge Prompt is VOLTAGE SEALLS JES n Yes No enable disab
26. amic weighing 1 13 6 Available Check Weighing Mode Parts Counting Mode Percentage Working Mode 1 13 7 Available Measure Unit kg g lb oz lb 0z PCS 1 13 8 Data Comparison and indicator of High OK and Low is available in Weighing mode Parts Counting mode and Percentage Working mode 1 13 9 Battery voltage is low and charging indicator 1 13 10 Programmable what content will be output and when they are output on serial port 1 13 11 Optional BMI function KILOTECH INC www kilotech com 5 2 Faceplate PeakiotalNer 0 D4 t Meaning of symbol on faceplate 2 3 NET 2 4 TOTAL 2 5 2 6 2 7 2 8 2 9 2 10 Ib oz kg g Pcs 2 11 PEAK 2 12 HOLD 2 13 BMI 2 14 HI 2 15 OK 2 16 LO 2 17 Iess turn on when scale is stable turn on when scale is at zero point and the gross weight is 0 turn on when net weight is displaying and the tare weight is not 0 turn off when gross weight is displaying turn on when display data is total times or total of weight pieces or percentage turn on when measure unit is Ib or Ib oz turn on when measure unit is oz or b 0z turn on when measure unit is kg turn on when measure unit is g turn on when in percentage weighing mode measure unit is turn on when in counting mode measure unit is pieces turn on when in working in HOLD mode and HOLD type is PEAK HOLD turn on and flashing not flashing working HOLD mode and displaying number is isn
27. aphical setting alters the calibration values III When INPUT is selected press TARE key to confirm to enter Input calibration parameters value that were got before or view current calibration parameters value All parameters about calibration are divided to 18 pages to be displayed on LCD by nn xxxx format nn is a decimal number of page xxxx is an hexadecimal value of parameter e g 02 85E2 01 02 pages zero code 03 04 pages standard weight of CAL P1 05 06 pages codes of CAL P1 07 08 pages standard weight of CAL P2 09 10 pages codes of CAL P2 11 12 pages full capacity net code 13 14 pages the coefficient of weight fine tune 15 16 pages gravity value of calibration location 17 18 pages gravity value of the location that the scale is used at When no digit blink on LCD that means calibration parameters value are being viewed and use UNIT key to view next page use ZERO key to exit When parameters value are being viewed use DATA key to prepare to modify When first digit is blinked that means the value is being modified and you can use UNIT key to make next digit flash if current flashing position is the last one next page value will be shown use PRINT ACC UNIT key to input number use TARE key to confirm In this mode press down PRINT key more than three seconds these parameters will be sent out from COM1 the print out format is lt LF gt nn xxxx lt CR gt there re totally eighteen lines
28. com 27 9 HOLD Function NOTE n trade application HOLD function may not be allowed please check with your local legal organization of measurement 9 1 HOLD function can be used to freeze display number In this mode scale can catch a dynamic number hold a stable number or average a unstable number then HOLD freeze this number temporary for user to watch or record This function can be used in normal weighing mode counting mode and percent weighing mode After entering HOLD mode the speed of A D converter can be increased to 80Hz if CONFIG AD H SPD is set to YES from original 10Hz for some dynamic weighing applications With the hold function it is possible to weigh restless weighing samples such as live animals moving objects The indicator provides special mode settings to accommodate sample s movements 9 2 To make HOLD function be active the CONFIG FUNC HOLD menu item must be set to YES menu items of USER HOLD HLD MOD AVGTIM HLD TIM HLD RNG STB TIM USER OTHER NLD RNG need be set to reasonable value To speedup sampling of weight set CONFIG AD H SPD menu item to YES To enter HOLD working mode press down HOLD key when scale works in normal weighing mode counting mode or percent weighing mode 9 3 There re several HOLD mode to freeze display data 1 Positive Peak Number HOLD mode 2 Negative Peak Number HOLD mode 3 Toggle HOLD mode 4 Average HOLD mode 5 Auto HOLD mode The following are details of thes
29. correct number make sure capacity not more than 6 digit Calibration error maybe input data or Input correct data load correct CAL Er loaded weight is too small too big weight onto platform Service unstable un linear required Piece weight is error it s too small lt 0 5d The weight on the platform is f PWT ER i f Use a greater weight for the sample too small to define a valid reference weight Unit Percentage Weight is error it s too small the weight of 1 0 1 or 0 01 PCT ER determined by Use a greater weight for the sample CONFIG FUNC PERCNT is less than 0 5d KILOTECH INC www kilotech com 47 CACU ER Internal calculation overflow Adjust the value of the PWT or PCT STB ER USER HOLD STB TIM is too short USER HOLD HLD RNG is too small other failure Set USER HOLD STB TIM longer or set USER HOLD HLD RNG bigger Service required Not turn on Power cord not plugged in or properly connected Power outlet not supplying electricity Battery discharged Other failure Check power cord connections Make sure power cord is plugged into the power outlet Check power source Replace batteries Service required Cannot zero the display or will not zero when turned on Load on scale exceeds allowable limits Load on scale is not stable Load cell damage Remove load on scale Wait for load to become stable Service required Cannot disp
30. e HOLD modes 9 3 1 Positive Peak HOLD When USER HOLD HLD MOD is set to PS PEAK the hold mode is positive peak hold mode When scale first enters this working mode it will display the largest positive number that is from the time of zero pint set After entering this working mode scale will always catches and refresh positive larger number and display it To exit HOLD mode press HOLD key again 9 3 2 Negative Peak HOLD When USER HOLD HLD MOD is set to NG PEAK the hold mode is negative peak hold mode When scale first enters this working mode it will display the largest negative number that is from the time of zero point set After entering this working mode scale will always catches negative larger number and display it To exit HOLD mode press HOLD key again 9 3 3 Toggle HOLD When USER HOLD HLD MOD is set to TOGGLE the hold mode is toggle hold mode a manual Hold function After entering this working mode scale will freeze and display number if scale is stable Only the weight that is over USER OTHER NLD RNG zero dead band can be held To exit HOLD mode KILOTECH INC www kilotech com 28 press HOLD key again If the time of scale being unstable is more than USER HOLD STB TIM STB ER will be shown press TARE key to start averaging again or press HOLD key to exit 9 3 4 Average HOLD When USER HOLD HLD MOD is set to AVERAG the hold mode is average hold mode After entering this working mode scale will freeze and display
31. e zero weight will become steady and then go to next step When first default standard weight is displayed after CAL P1 being shown It will be calibrated on standard weight for first point Put corresponding weight more than 10 FS weight onto scale The default standard weight is 100 FS Use PRINT ACC UNIT keys to input the value of the loaded weight Before input this value you can long press DATA key to change weight s unit to kg or lb Press TARE key to confirm then the indicator will flash the input standard weight When this weight number becomes steady it means the stable and reasonable data corresponding to the standard weight has been gotten After this the indicator will automatically go to next step If this point can t be calibrated correctly maybe the weight load onto scale is too small maybe the input data is incorrect it will display CAL Er and return back to step12 5 1 for re calibration When End y is shown and y is flashing it s waiting command to exit calibration or go on next calibration Use PRINT or ACC key to select yes or no use TARE to confirm If yes is selected it will go to step12 8 to end calibration if no is selected it will go to next step When 100 FS weight is displayed after CAL P2 being shown It will be calibrated on standard weight for second point Put corresponding weight more than 10 FS weight and larger than the weight used on CAL P1 onto scale Next operation is same as what in s
32. eight which quantity in counting mode press UNIT key When InP PWt is shown use PRINT or ACC key to select SPL PWT press TARE key to weigh samples which quantity is known weight calculate piece weight Press ZERO key to exit getting piece weight mode and back to counting mode 6 5 2 1 When SPL Lo is shown move away any sample on scale and press TARE key to confirm before scale is stable SPL Lo will be flashed After it is stable it will go to next step Press ZERO key to exit getting piece weight mode and back to counting mode 6 5 2 2 When SPL Hi is shown put samples its quantity is known onto the scale Press TARE key to confirm reading weight Before scale is stable SPL Hi will be flashed After it is stable it will go to next step Press ZERO key to exit getting piece weight mode and back to counting mode 6 5 2 3 After INP PCS being shown 000000 will be displayed use PRINT ACC UNIT key to input the quantity of samples and Press TARE key to confirm If the calculated piece weight is less than 0 5d the indicator will display PWt Er and go back to counting mode otherwise after the reasonable piece weight being got the scale will go back to counting mode The got piece weight can be saved after the power off and can be used next time 6 6 Check Counts counts compare in Counting mode 6 6 1 To make counts compare function be available CONFIG FUNC COMPAR item should set to YES and high and low limitation of pieces should be
33. er off press down gt 3s Input data mode ignore modification Menu selection mode Prepare to exit from current working mode Note Normally the second function of one key need pressing it down more than 3s KILOTECH INC www kilotech com 8 4 Operation Menu Structure 4 1 Main menu 4 2 CONFIG Submenu Sub Sub e Menn Menu Option Default Remark IT mM ae seal switch is on or off PESEE SCH Ilo reset configure parameters to default setting MofE FELULA USA mong _ select the standard that the scale will comply with CARAJA 768 USA CANADA EUROPE Eur oPE IDE p p inn nn 3000 the division number under primary unit He Dr So UUU if REGULAR none the max is 10 000 MANN f LLEI LILI DODGE 00005 Aaf TE 0005 D I gc the division value under primary unit the division ue OS value under second unit is automatically determined Li E by indicator according to the division value under ge primary unit U5 E 5 ID SH Sa E EL Select the primary unit from kg or lb BF 1 RUE PL The second unit is the Ib if kg selected as primary unit Lh or kg if Ib selected as primary unit KILOTECH INC www kilotech com 9 GU the division number under second unit the max is SEL Nall fe HI J000 1 25 PRIM N o if REGULAR none
34. er will beep whatever USER BEEP KEY item is set 20 3 Press SETUP key to return to last menu item press ON OFF key to prepare to exit this mode 21 Serial Port1 2 COM1 2 Receiving Test 21 1 Before test the receiving function of COM1 or COM2 a cable is need to connect a PC and this indicator and a software be similar with Super Terminal of Windows is also need to run on PC to send bytes to this indicator Please note baud rate is selected by USER COM1 2 BAUDRT 8N1 byte format is fixed Hex data 0x00 Oxff are used 21 2 Press down SETUP more than 3s to enter SETUP mode using PRINT or ACC key to select TEST COM1 RD or TEST COM2 RD item press TARE to enter test COM1 2 receiving function and rd1 or rd2 will be displayed first 21 3 In this mode received hex data 0x00 Oxff will be displayed on position 21 4 Press SETUP key to return to last menu item press ON OFF key to prepare to exit this mode 22 Serial Port1 2 COM1 2 Transmitting Test 22 1 Before test the transmitting function of COM1 or COM2 a cable is need to connect a PC and this instrument and a software be similar with Super Terminal of Windows is also need to run on PC to receive bytes from this instrument Please note baud rate is selected by USER COM1 2 BAUDRT 8N1 byte format is fixed Hex data 0x00 Oxff are used 22 2 Press down SETUP more than 3s to enter SETUP mode using PRINT or ACC key to select TEST COM1 TD or TEST COM2 TD item pres
35. ers the field of polarity decimal point weight data is filled by 23 4 3 If the weight is under capacity it will return eight _ characters the field of polarity decimal point and weight data is filled by _ 23 4 4 If the zero point is error it will return eight characters the field of polarity decimal point and weight data is filled by 23 4 5 Useless leading 0 before digits is suppressed Reading weight is right aligned 23 5 Key to symbols used lt LF gt Line Feed character hex OAH lt CR gt Carriage Return character hex ODH lt ETX gt End of Text character hex 03H lt SP gt Space hex 20H H1H2H3 H4 Four current status bytes lt P gt Polarity character or W 1 W6 Reading data 1 6 bytes six digits lt DP gt Decimal point U1U2 U3U4U5 Measure units kg lb Ib oz or pcs 2 5 bytes lt Add gt Address of scale 2 bytes 00 99 lt Prompt gt Prompt characters of output content max 11bytes KILOTECH INC www kilotech com 37 The bit definition of H H2H3 H4 Bit Byte 1 H1 Byte 2 H2 Byte 3 H3 Byte 4 H4 9 P stable O not under capacity 9 compare disable 00 normal weighing 1 not stable 1 under capacity 01 lower limit 01 count weighing O not at zero point 0 notovercapacity ok 10 percent weighing 1 11 upper limit 11 other mode 1 at zero point 1 over capacity 2 O RAM ok
36. go back to percent weighing mode The got unit percentage weight can be saved after the power off and can be used next time 7 6 Check Percent percentage compare in Percent weighing mode 7 6 1 To make percentage compare function be available CONFIG FUNC COMPAR menu item should set to YES and high and low limitation of percentage should be set correctly according to following steps 7 6 2 In percent weighing mode Press down DATA key more than 3s to input compare data of high and low 7 6 3 After HIGH being shown 000000 will be displayed use PRINT ACC UNIT key to input high percentage number and press TARE key to confirm Announciator of Hi will be shown in this step Press ZERO key to exit and back to percent weighing mode 7 6 4 After Low being shown 000000 will be displayed use PRINT ACC UNIT key to input low percentage number and press TARE key to confirm Announciator of Lo will be shown in this step Press ZERO key to exit and back to counting mode NOTE If High number is 0 or is equal or less than low number the comparison will be disabled 7 6 5 After a reasonable limitation is set and compare is be active one of announciators HI OK LO will be lighted and the beeper will sound according to its setting in USER BEEP 8 BMI Working Mode 8 1 To make BMI working Mode be available CONFIG FUNC BMI menu item should be set to YES and factory setting should be also enable this function 8 2 To enter BMI Working mode 8 2 1 Whe
37. is over NLD RNG put on scale the new load will be automatically frozen average data time for HOLD mode 1 60s Waiting time for scale stable in HOLD mode 3 AVG TIM 255S oJ Data HOLD time 0 data will be frozen until HOLD key pressed 1 65535 data frozen time is 1 65535s after the time elapses scale will exit HOLD mode Vibration range of data that can be averaged and held in HOLD mode O any data can be averaged 1 255 only the data which vibration is in 1 255d can be averaged and held Ee ES 1 255 the range of weight is 1 255d when current weight is less than this value the scale can be regarded as empty or the load on scale is removed It must be bigger than CONFI MOTION Source of the executed command selection 1 NONE no any command will be executed 2 COM 1 2 3 command from COM1 2 3 will be executed 3 COM 1 2 1 3 2 3 command from COM1 COM2 COM1 COM3 or COM2 COM3 will be executed 4 COM 1 2 3 command from COM1 COM2 or COM3 will be executed NOTE if AD AFROM COMS then COM x x 3 will not be active RoFFE Auto off time O not auto power off 1 255 auto power off after 1 255 minutes in this period no operation or no weight changing KILOTECH INC www kilotech com 17 Auto off mode oft 1 OFF turn off instrument 2 DSP TIM display time 3 AC TIME turn off when oFF nd ASPER ott o
38. issem 34 14 View ADC output Code nnnnnnnenenss 34 15 View or Calibrate Power Voltage 35 16 View or Set AN xaos ccss eee cscccs enc htececsectncceneecteneenttesnancnencucnsenscunseceeas 35 17 View OF Set DANG octiirtcccecintnncecnncecantstnnecannnecuuassoetetnnnnecnsthnoeneecnaceae 35 18 View Firmware Version 36 19 Display TS ni en aa 36 20 Keyboard and Buzzer Test ns 36 21 Serial Port1 2 COM1 2 Receiving Test ms 36 22 Serial Port1 2 COM1 2 Transmitting Test 36 23 Details about Serial Communication 37 25 Meaning of Some Symbols and Troubleshooting eessen 46 26 Display ChaFacier 2 ue 49 27 PACKS ee ceeeecee ee Seeence eeeceenpeaaceesp acdee acnacheneaceccespacaatearencacaetecs 50 KILOTECH INC www kilotech com KIN 500 Indicator Operation Manual Thank you for purchasing the KIN 500 indicator Please read all operating instructions carefully before use and keep the following points in mind Avoid lengthy exposure to extreme heat or cold your scale works best when operated at normal room temperature Always allow the scale to acclimate to a normal room temperature before use Always use a proper power supply and well connected load cell Allow sufficient warm up time Turn the scale on and wait for a few minutes if possible to give the internal components a chance to stabilize before weighing These electronic scales are precision instruments Do not operate near an in u
39. it on flashed position subtract 1 Menu selection mode To Next item of current menu press down lt 3s press down lt 3s UINT DATA The digit on flashed position add 1 To last item of current menu Change weighing units kg gt lb gt lb oz not be available in some conditions gt kg To enter getting piece weight or unit percentage weight mode by way of sample or input directly Weighing Counting Percent mode To input compare data for weight pieces or percentage press down gt 3s of high and low limitation Display date or time mode To set current date or time press down gt 3s a KILOTECHING INC www kilotech com 7 Display voltage mode To calibrate input voltage value press down gt 3s Display ADC code Select displaying code from no filter filter1 filter2 Input data mode Rotate the flashed position from left to right Weighing Counting Percent Tare function press down lt 3s TARE Weighing Counting Percent To input pre set tare weight at selected weight unit PRESET press down gt 3s des 2 lt Input data mode or To confirm input data or current item selection and go to Menu selection mode next item of current menu or next operation Display ADC code Set or clear tare code Power off mode Power on Weighing Counting Percent f Zero function ZERO Press down lt 3s ON OFF Weighing Counting Percent Si Pow
40. lay weight in desired weighing unit Unit not set to enable or d250z when unit is Ib oz Enable unit in CONFIG UNITS Battery symbol is empty or Lo bAt is shown Batteries are discharged Charge batteries KILOTECH INC www kilotech com 48 26 Display Character ASCII LCD LED Show ASCII LCD LED Show ASCII LCD LED Show 1 l B H o o 2 d c H P H 3 J D d a U 4 I E E R j 5 d F E s L 6 D G H T l 8 ea felu e i vi e H 3 H v H K H x H P i B e f H KILOTECH INC www kilotech com 27 Packing List No CONTENT QTY 1 Indicator 1 2 User manual 1 3 Swivel bracket 1 4 1x CR2032 battery for RTC 1 5 AC Adapter 1 6 RS232 cable Optional 7 USB interface 1 8 USB cable Optional 9 4xAA Alkaline batteries 4 KILOTECH INC www kilotech com 50
41. le output scale s status Prompt is LI fo 110 STATUS Moll LE How many blank lines after strings output NONE no bL NE Layee LiNE blank line LINE1 2 3 4 there re 1 2 3 or 4 blank lines WEE after strings used for paper feed forward 1 2 3 4 lines Lui L NEH SES FEY HES Yes No enable disable beep after a key pressed down fa MoftE ire 1 NONE not beep bEEP LEE 2 L Low beep when lower than low limitation E 3 IN LMT beep when in range of low and high ConPhr HLL Ae HILL ot limitation 4 O HIGH beep when over high limitation oH GH 5 OUT LMT beep when lower than low limitation or 7 higher than high limitation GUE L nE KILOTECH INC www kilotech com 16 Hi d nod HUE HOLD Mode 1 NONE no hold function 2 PS PEAK Positive Peak number Hold mode scale will display and refresh the positive peak value from last zero setting 3 NG PEAK Negative PEAK number Hold mode it s Similar with PS PEAK but negative number is used 4 TOGGLE Press HOLD key to enter HOLD mode if weight is over NLD RNG and stable the data will be frozen until press HOLD key again to exit 5 AVERAG Average HOLD mode in this mode if weight is over NLD RNG and its variation is less than HLD RNG the average data in AVG TIM will be frozen Press HOLD key or HLD TIM time elapsed to exit this mode 6 AUTO Auto hold mode it s similar with AVERAG mode but if the one held load is removed and a new load that
42. lighted in other HOLD mode green HOLD for LED version or HOLD for LCD version announciator will be lighted When HOLD announciator flash the displayed number is live When HOLD announciator become steady the displayed number is frozen 10 Data Compare Function 10 1 Data compare function can be used in normal weighing mode counting mode and percent weighing mode and call it as Check Weight Check Counts and Check Percentage When this function is enabled you can set a higher and a lower limitation of weight counts or percentage independently and these limitation can be saved permanently Then the current data of weight counts or percentage will be compared with the setting limitation and corresponding announciator will be lighted 10 2 To make data compare function be available CONFIG FUNC COMPAR menu item should set to YES and high and low limitation should be set correctly according to following steps 10 3 In normal weighing mode counting mode or percent weighing mode Press down DATA key more than 3s to enter input compare data of high and low mode 10 4 After HIGH being shown last setting data of high will be displayed use PRINT ACC UNIT key to input new number of high and press TARE key to confirm Announciator of Hi will be shown in this step Press KILOTECH INC www kilotech com 29 ZERO key to exit and back to original working mode 10 5 After Low being shown last setting of low will be displayed use PRINT AC
43. mode in normal weighing or counting mode long press FUNC key WEIGH COUNT will be shown use ACC or PRINT key to select PERCEN then press TARE to confirm go to percent weighing mode Before new unit percentage weight is got the last unit percentage weight will be used 7 4 In percent weighing mode the function of ZERO TARE PRINT HOLD PRESET TARE ACC SETUP ON OFF are available 7 5 To obtain the unit percentage weight there re two ways 1 input weight and its percentage then scale calculates the unit percentage weight refer operations of step7 5 1 2 weigh samples weight which percentage is known refer operation of step7 5 2 7 5 1 Input weight and its percentage from keypad and calculate unit percentage weight in percent weighing mode press UNIT key When InP Pct is shown press TARE key to enter this mode 7 5 1 1 Before input weight use PRINT or ACC key to select the percentage from 1 2 5 10 20 50 and 100 this percentage is corresponding to the weight you will input in following steps 7 5 1 2 When UNIT KG is shown use PRINT or ACC key to select the unit of input weight use TARE key to confirm and go to next Press ZERO key to exit and back to percent weighing mode 7 5 1 3 When last stored unit percentage weight data is shown use PRINT ACC UNIT key to input new unit percentage weight press HOLD key more than 3s to input decimal point Press TARE key to confirm and save it then go back to percent weighing m
44. n CONFIG FUNC ACCUMU Yes If In normal weighing mode percent weighing mode or counting mode long press FUNC key one of WEIGH COUNT PERCEN will be shown use ACC or PRINT key to select BMI then press TARE to confirm go to BMI mode 8 2 2 When CONFIG FUNC ACCUMU NO press BMI ACC key go to BMI mode 8 3 After scale go to this mode CM xxx means last input height is xxx cm or IN xx x means last input height is xx x inch will be displayed and to wait for input height 1 to change height unit to cm or inch by pressing DATA key 2 to change height number by using PRINT ACC BMI keys 3 Press and hold down PRINT or ACC BMI key will increase or decrease number fast 4 Press TARE key to confirm the input Press ON OFF key to exit input data mode and back to BMI working mode The range of height is 50 250cm 19 7 98 4inch and default is 170cm 66 9inch 8 4 In this mode when BMI number is shown BMI announciato is on also or weight number is shown BMI and kg or Ib announciators are on Press ACC key to select weight or BMI number to be displayed when weight is displayed the weight unit can be selected by pressing UNIT key and BMI and weight unit will be displayed at same time 8 5 In this mode when current net weight is less than NLD RNG the indicator will go to display weight number if CONFIG FUNC ACCUMU YES or the indicator will back to original working mode if CONFIG FUNC ACCUMU NO KILOTECH INC www kilotech
45. n UNIT more than 3s to enter modification date mode Using PRINT ACC UNIT TARE keys to modify current date If time of no operation is more than 5s it will automatically exit modification mode 17 4 Press SETUP key to return to last menu item press ON OFF key to prepare to exit this mode KILOTECH INC www kilotech com 35 18 View Firmware Version 18 1 Press down SETUP until CONFIG is shown using PRINT or ACC key to select MISC VER item press TARE to display current Version 18 2 Firmware Version display Format is Vxx yy xx is hardware version yy is software version 18 3 Press SETUP key to return to last menu item press ON OFF key to prepare to exit this mode 19 Display Test 19 1 Press down SETUP more than 3s to enter SETUP mode using PRINT or ACC key to select TEST DISP TST item press TARE to enter test display mode and all segments will be lighted first 19 2 In this mode every pressing of ACC key will light next segment every pressing of UNIT will light next digit press PRINT will automatically light all segments and all digits 19 3 Press SETUP key to return to last menu item press ON OFF key to prepare to exit this mode 20 Keyboard and Buzzer Test 20 1 Press down SETUP more than 3s to enter SETUP mode using PRINT or ACC key to select TEST key tst item press TARE to enter test keypad mode and key will be displayed 20 2 In this mode press a key the value of this key will be displayed on position and buzz
46. nly battery is used display time when AC adaptor is used Lee E If time is displayed and enabled continuously output to et COM x the time will be sent out LCD backlight set 1 0 always off 2 1 always on eee 1 255 30 2 2 press down ZERO UNIT together more than 3s to Fe S turn on or turn off 4 3 255 auto on when key operation or weight changing auto off after 3 255s elapsed LLdL5 5E Ebt l 8 LSEG LCD contraction level selection NANA rol U O D LI LI LI 1 LEE va 999909 123466 scale s ID number 000000 999999 NOTE if AD FROM COMS3 then COM3 and OUT3 will not be active KILOTECH INC www kilotech com 18 4 4 CAL Submenu CAL SUBMENU1 SUBMENU2 OPTION REMARK seal switch is on or off m IT D ES D co only do zero point calibration then go to CAL END to end Linear calibration point do zero point calibration this point can t be omitted IT D F Ka Linear calibration point1 do first weight point calibration this point can t be omitted and standard weight must be over 10 FS Ellas End calibration YES go to CAL END to end NO go to do next point calibration Linear calibration point2 do second weight point calibration standard weight must be over 10 FS and be larger than it in CAL P1 this point can be omitted Efid 4 aE End calibration YES go to CAL END to end NO go to do next point calibration Linear calibration p
47. number if scale is stable If scale is not stable but the variation is less than USER HOLD HLD RNG scale will average data in USER HOLD AVG TIM then freeze and display the number Only the weight that is over USER OTHER NLD RNG can be frozen Scale will exit HOLD mode according to the setting of USER HOLD HLD TIM If the time of scale variation being over USER OTHER NLD RNG is more than USER HOLD STB TIM STB ER will be shown press TARE to start averaging again or press HOLD key to exit 9 3 5 Auto HOLD When USER HOLD HLD MOD is set to AUTO the hold mode is auto hold mode different subjects can be weighed one after another without pressing any buttons After entering this working mode scale will freeze and display number if scale is stable If scale is not stable but the variation is less than USER HOLD HLD RNG scale will average data in USER HOLD AVG TIM then freeze and display the number Only the weight that is over USER OTHER NLD RNG can be frozen If the held weight is moved away and a new load put on the scale scale will automatically hold new number of load Scale will exit HOLD mode according to the setting of USER HOLD HLD TIM If the time of scale variation being over USER OTHER NLD RNG is more than USER HOLD STB TIM STB ER will be shown press TARE to start averaging again or press HOLD key to exit 9 4 In Positive or Negative Peak HOLD mode the red HOLD for LED version or PEAK and HOLD for LCD version announciator will be
48. ode If the calculated unit percentage weight is less than 0 5d the indicator will display Pct Er and go back to percent weighing mode 7 5 2 Obtain unit percentage weight by weighing samples weight which percentage is known in percent weighing mode press UNIT key When InP Pct is shown use PRINT or ACC key to select SPL Pct press TARE key to weigh samples which percentage is known weight calculate piece weight Press ZERO key to exit and back to percent weighing mode 7 5 2 1 When SPL Lo is shown move away any sample on scale and press TARE key to confirm before scale is stable SPL Lo will be flashed After it is stable it will go to next step Press ZERO key to exit and back to percent weighing mode 7 5 2 2 When SPL Hi is shown put samples its percentage is known onto the scale Press TARE key to confirm reading weight Before scale is stable SPL Hi will be flashed After it is stable it will go to next step Press ZERO key to exit and back to percent weighing mode 7 5 2 3 After INP PCT being shown 000000 position of decimal point is determined by CONFIG FUNC PERCEN setting will be displayed use PRINT ACC UNIT key to input the KILOTECH INC www kilotech com 26 percentage of samples and Press TARE key to confirm If the calculated unit percentage weight is less than 0 5d the indicator will display Pct Er and go back to percent weighing mode otherwise after the reasonable unit percentage weight being got the scale will
49. oint3 do third weight point calibration standard weight must be over 10 FS and be larger than it in CAL P2 this point can be omitted Lode NN T uu FLI Selection of Geographical Position Code 00 70 refer TABLE12 1 Lr AJE 9 ib IBJ 9 39997 Input Gravity of User Location by keyboard Input or view calibration parameters value ma D SS Fr D calibration end and restart NOTE The details can be referred in section 12 CALIBRATION KILOTECH INC www kilotech com 19 4 5 MISC Submenu MISC SUBMENU1 REMARK Fade display ADC s code this code can be after no filter filter1 or filter2 details refer to Ger section14 vol display voltage calibrate voltage details refer to section15 dAEE display date and set date details refer to section17 bank display time and set time details refer to section16 Her display firmware version details refer to section18 4 6 TEST Submenu TEST SUBMENU1 REMARK d 5PESE test LCD or LED details refer to section19 Lon ird test COM1 receiving details refer to section21 Lon ltd test COM1 transmitting details refer to section22 Lonerd test COM2 receiving details refer to section21 Conctd test COM2 transmitting details refer to section22 HEEL test keys and buzzer details refer to section20 KILOTECH INC www kilotech com 20 5 Normal Weighing mode 5 1 During key operation
50. on speed is set high speed 80Hz and USER COM1 2 LAYOUT is set to MULTIPLE and many contents are selected to output the output contents from COM1 or COM2 may not catch up with the data processed in indicator So if you want to watch real time data you need to select fewer output contents and set higher baud rate for C lt CR gt USER OUT1 2 LINE is set to LINE1 2 3 4 The number of blank lines is determined by USER OUT1 2 LINE setting lt ETX gt Last byte of string frame 23 7 2 Examples of some layout when USER OUT1 2 xxxx is set to YES USER COM2 EN ADDR No 23 7 2 1 In weighing mode SCALE ID 123456 GROSS 123lb 4 560z TARE 111b 2 220z NET 1121b 2 340z ACC N 8 TOTAL 789lb 15 20z DATE 2011 06 12 TIME 12 34 56 A D CODE 1234567 VOLTAGE 6 7V STATUS bpq2 23 7 2 2 In counting mode SCALE ID 123456 GROSS 1234 55kg TARE 12 15kg NET 1222 40kg QUANTITY 24448pcs PIECE WT 0 05kg ACC N 10 TOTAL 23456pcs KILOTECH INC www kilotech com 40 23 7 2 3 In percent weighing mode 23 7 2 4 In BMI mode DATE 2011 06 12 TIME 12 34 56 A D CODE 1234345 VOLTAGE 6 7V STATUS bpq2 SCALE ID 123456 GROSS 12345lb TARE 101b NET 12335lb PERCENTAGE 91 4 1 REF WT 1351b ACC N 3 TOTAL 271 6 DATE 2011 06 12 TIME 12 34 56 A D CODE 1231234 VOLTAGE 6 7V STATUS bpq2 SCALE ID 123456 GROSS 110 0kg TARE 10 0kg NET 100 0kg HEIGHT 170cm BMI 34 6 DATE 2011 06 12 TIME 12
51. orking mode press down SETUP until CONFIG is shown using PRINT ACC and TARE key to to go to MISC Code item press TARE to enter this mode and display ADC output raw code 14 3 In this mode first press TARE key can set current code as a reference zero and then to display net code press TARE again to clear this reference and display gross code 14 4 In this mode press UNIT key to select displaying code that has been filtered by no filter filter1 or filter1 and filter2 and corresponding announciator Lo OK HI will be lighted 14 5 Press SETUP key to return to last menu item press ON OFF key to prepare to exit this mode KILOTECH INC www kilotech com 34 15 View or Calibrate Power Voltage 15 1 In this mode you can examine the voltage of battery or you can examine the voltage that regulated out from AC adaptor when no battery is used you also can calibrate the displayed voltage and set the voltage value of low battery point Note 1 The end customer normally no need to calibrate the displayed voltage these have been done in factory 2 The normal displaying voltage is 4 0V 6 0V 15 2 To go to this working mode press down SETUP until CONFIG is shown using PRINT ACC and TARE key to to go to MISC VoL item press TARE to enter this mode and display battery voltage 15 3 If the voltage is sure not correct to calibrate the voltage according to following steps 15 3 1 Prepare a DC power supply which output voltage can be adju
52. parity check bit 1 stop bit BIEFnE iE ail i 3 7E1 7 data bits 1 Even parity check bit 1 stop bit 2 4 702 7 data bits 1 Odd parity check bit 2 stop bit Si 5 7E2 7 data bits 1 Even parity check bit 2 stop bit TEC KILOTECH INC www kilotech com 13 11 Ee Holle Selection com2 output mode mo 1 NONE No communication Loft 2 CONT continuously output 3 PRINT output after PRINT key pressed Pri fE TEE KT ae ee 4 CMD output after a request command is received Peres R ret 5 PRT CMD output after PRINT key pressed or Cad E request command received BEES 6 STABLE output after scale is stable LEA Note use PRINT or CMD to output data the scale must LE Ab E be stable Sen com2 output content and format set AULEPL 1 MULTPL the following selected item in OUT2 will be output use defined format D AGLE 2 SINGLE only displayed content and current status AUOUE dus up Will be output it s compatible with NCI SCP01 Biya MULET EL 3 EH SCP Command response mode similar to et Toledo PS60 protocol 4 SCP 12 only displayed content and current status LCP ie will be output it s compatible with NCI SCP12 NCI3835 ER sd S S Yes No enable disable output scale s ID number EE fiz E Prompt is SCALE ID ERTI El e Yes No enable disable output gross weight Prompt is O fs 110 GROSS
53. parity check bit 2 stop bit Me Iolft Selection com1 output mode lon 1 NONE No communication Loni ron Loft 2 CONT continuously output pa 3 PRINT output after PRINT key pressed Herod Sdt BEE 4 CMD output after a request command is received M Sc re 5 PRT CMD output after PRINT key pressed or request command received PrEL nd 6 STABLE output after scale is stable Note use PRINT or CMD to output data the scale must SEAGLE be stable 8 com1 output content and format set ell EH 1 MULTPL the following selected item in OUT1 will be output using defined format 4i NGLE 2 SINGLE only displayed content and current status AYoUE LL LPI will be output it s compatible with NCI SCP01 es a MULETE 3 EH SCP Command response mode similar to EN ALP Toledo PS60 protocol 4 SCP 12 only displayed content and current status CP p will be output its compatible with NCI SCP12 NCI3835 LED sd DES e Yes No enable disable output scale s ID number Et To Ge Prompt is SCALE ID G ob5 JE5 Se Yes No enable disable output gross weight Prompt is ro fs 110 GROSS JE Yes No enable disable output tare weight Prompt is out EArE 7 fo ARE H g H DEL YE5 YES Yes No enable disable output net weight Prompt is fis NET DE FE JE m Yes No enable disable output weight percentage E To gt Prompt is PERCENTAGE KILOTECH INC www kilotech com 12
54. s TARE to enter test COM1 2 transmitting function and td1 or td2 will be displayed first KILOTECH INC www kilotech com 36 22 3 In this mode transmitted hex data 0x00 Oxff will be displayed on position and PRINT ACC UNIT TARE keys can be used to modify transmitted data 22 4 Press SETUP key to return to last menu item press ON OFF key to prepare to exit this mode 23 Details about Serial Communication 23 1 COM is RS232 communication wires come from RS232 connector and TXDO RXDO and GND are used Please refer to section 24 5 connector details 23 2 COM2 is USB used as a virtual RS232 communication wires come from USB connector and TXD1 RXD1 and GND are used Please refer to section 24 6 for connector details 23 3 The baud rate and byte format is set by USER COM1 2 BAUD RT and USER COM1 2 BYT FMT Responses to serial commands will be immediate or within one weight measure cycle of the scale One second should be adequate for use as a time out value by remote controlling device 23 4 The length of each item in a transition string 23 4 1 Reading data Gbytes Data polarity 1byte for negative and followed the first digit for positive Decimal point 1byte Measure unit 1 5bytes Ib kg Ib 0z pcs Units are always lower case left aligned Current status 4bytes 23 4 2 If the weight is overcapacity the scale will return eight charact
55. se cell phone radio computer or other electronic device These devices emit RF and can cause unstable scale readings If your scale ever performs poorly try moving the scale to a different room or location Avoid using in condition of heavy vibration and airflow Read the weight reading in short time after loading The output signature of load cell and electronic circuit may be little influenced after weighing for a long time Some functions maybe disabled by manufacture before shipping if you need these functions or don t want to use some other functions please contact with manufacture in advance because of this some operations or faceplate maybe are a little bit different and some description sections may be deleted 1 Specification 1 1 Outline and Bracket installation 1 1 1 Outline A pigtail of 7 pin circle socket is used and load cell wires go to this indicator from the back side the outline is similar as following fig shown in some not trade application the seal may not be installed Back View Right View KILOTECH INC www kilotech com 2 1 1 2 Indicator bracket installation 1 1 2 1 According to following figure use locknut to fasten Dart and part2 onto the bracket and make sure part1 and part2 in correct direction KILOTECH INC www kilotech com 3 1 2 Power Supply 1 2 1 4xAA size alkaline batteries When the sign of battery is empty this prompt
56. set correctly according to following steps 6 6 2 In counting working mode Press down DATA key more than 3s to input compare data of high and low 6 6 3 After HIGH being shown 000000 will be displayed use PRINT ACC UNIT key to input high quantity number and press TARE key to confirm Announciator of Hi will be shown in this step Press ZERO key to exit getting piece weight mode and back to counting mode 6 6 4 After Low being shown 000000 will be displayed use PRINT ACC UNIT key to input low quantity number and press TARE key to confirm Announciator of Lo will be shown in this step Press ZERO key to exit getting piece weight mode and back to counting mode NOTE If High number is 0 or is equal or less than low number the comparison will be disabled 6 6 5 After a reasonable limitation is set and compare is be active one of announciators HI OK LO will be lighted and the beeper will sound according to its setting in USER BEEP KILOTECH INC www kilotech com 25 7 Percent Weighing Mode 7 1 In this mode scale will weigh goods weight on it calculate and display its percentage after the unit percentage weight of goods is obtained NOTE If 100 display format is set to 100 100 0 or 100 00 in CONFIG FUNC PERCEN menu item then the unit percentage weight is the weight of 1 0 1 or 0 01 7 2 To make percent weighing function be available CONFIG FUNC PERCEN menu item shouldn t be set to NONE 7 3 To enter percent weighing
57. sted from 5V to 8V output current must be larger than 0 5A Power off the indicator move away AC adaptor Connect this DC power to battery connector on main board adjust voltage to about 5V power on the indicator enter battery voltage display mode by the way of step15 2 15 3 2 Press down UNIT until CAL 5V is shown adjust voltage to 5V press TARE key to confirm 5V calibration 15 3 3 When CAL 6V is shown adjust voltage to 6V press TARE key to confirm 6V calibration When CV End is shown that means the voltage calibration is completed and then exit to display voltage 15 4 Press SETUP key to return to last menu item press ON OFF key to prepare to exit this mode 16 View or Set Time 16 1 After entering SETUP mode by press down SETUP key more than 3s using PRINT or ACC key to select MISC TIME item press TARE to display current time 16 2 Time display Format is xx xx xx hh mm ss 24h format 16 3 Press down UNIT more than 3s to enter modification time mode Using PRINT ACC UNIT TARE keys to modify current time If time of no operation is more than 5s it will automatically exit modification mode 16 4 Press SETUP key to return to last menu item press ON OFF key to prepare to exit this mode 17 View or Set Date 17 1 After entering SETUP mode by press down SETUP key more than 3s using PRINT or ACC key to select MISC DATE item press TARE to display current time 17 2 Date display Format is xx xx xx yy mm dd 17 3 Press dow
58. t 0 5d 25 1 31 SPL PCT Sample goods weight to calculate 25 1 32 INP PCT input percentage of weighted goods 25 1 33 PCT ER Unit Percentage Weight is too small lt 0 5d 25 1 34 CACU ER Internal calculation overflows KILOTECH INC www kilotech com 46 25 2 Troubleshooting SYMPTOM PROBABLE CAUSE REMEDY Load cell wires to indicator are Make sure wires are ok and correctly incorrectly connected or shorted or connected Replace load cell or ADC Ad opened or ADC load cell are damaged chip Service required Weight reading exceeds Power On Zero Make sure scale platform is empty 0 limit Perform zero calibration 0 Weight reading below Power On Zero Install platform on scale Perform GE limit zero calibration f gt _ Reduce load on scale until weight Weight reading exceeds Overload limit value can be displayed Use a more See or The weight value cannot be displayed i _ appropriate unit of measure Re set in the current unit of measure because it o some parameters of CONFIG or exceeds 6 digits UAER f ao Install platform on scale Se Weight reading below Under load limit a Perform zero calibration EE CONFIG or CAL parameters are not Re set items in CONFIG do correctly set calibration EEP E2 USER parameter is not correctly set Re set items in USER Set PRIM N PRIM d SECND n to CAP ER Capacity parameters are not correct
59. t live turn on when working in BMI mode turns on when data compare is enabled and current data weight pieces or percent is over its upper setting limitation turns on when data compare is enabled and current data weight pieces or percent is between its high limitation and low limitation turn on when data compare is enabled and current data weight pieces or percent is below its lower limitation turn on when battery is used or charged KILOTECH INC www kilotech com 6 3 Summary of Key function Weighing Counting Percent Function Enter or exit HOLD mode press down lt 3s press down gt 3s press down gt 3s Input data mode To enter setup mode to input decimal point Return to last sub menu press down lt 3s Menu selection mode Return to last sub menu press down lt 3s PRINT Weighing Counting Percent FUNC press down gt 3s Output data to serial communication port select working mode weighing counting or percent Input data mode Menu selection mode ACCUMULATION function is enabled in configuration Weighing Counting Percent BMI menu To add up current weight pieces percentage to press down lt 3s memory display times and total of accumulation in BMI working mode to input height ACC TOTAL Weighing Counting Percent ACCUMULATION function is enabled in configuration menu press down gt 3s To display times and total of accumulation Input data mode the dig
60. tep12 5 2 When End y is shown and y is flashing Use PRINT or ACC key to select yes or no use TARE to confirm Similar with doing in step12 5 3 When third standard weight displayed after CAL P3 being shown It will be calibrated on standard KILOTECH INC www kilotech com 31 12 5 7 12 6 12 6 1 12 6 2 12 6 3 12 7 12 7 1 12 7 2 12 7 3 12 7 4 weight for third point Put corresponding weight more than 10 FS weight and larger than the weight used on CAL P2 onto scale Next operation is same as what in step12 5 2 When the stable and reasonable data corresponding to the standard weight has been gotten The indicator will automatically go to Step12 8 Otherwise it will display CAL Er and return back When GEO is selected press TARE key to confirm to enter Geographical Adjustment When CODE is shown use PRINT or ACC key to select geographical position code refer step12 6 2 or input user local gravity value directly refer step12 6 3 When CODE is selected select the position code of scale being used 00 70 according to the elevation and latitude from Table12 1 by using PRINT ACC UNIT keys Press TARE key to confirm When GRAVT is selected Use PRINT ACC UNIT keys to input the gravity value of the position that scale is used 9 76183 9 99999 Press TARE key to confirm NOTE Only an authorized manufacturer s representative or certified verification personnel may make these changes Changing the geogr
61. the original load should be removed and let load on scale be smaller than USER OTHER NLD RNG 11 4 When CONFIG FUNC ACCUMU is set to AUTO the stable and positive displayed net weight must be larger than USER OTHER NLD RNG piece or percentage can be accumulated automatically and indicator will display accumulation times first and then display total of number To avoid repeating accumulation for same load one load only can be accumulated once So before a new load put onto the scale the original load should be removed and let load on scale be smaller than USER OTHER NLD RNG 11 5 To view total when display number is zero long pressing TOTAL key and indicator will display accumulation times first and then display total of number It will alternative display accumulation times and weight or quantity or percentages until the TOTAL key being pressed again NOTE When HOLD function is enable and scale is working in PEAK HOLD mode CONFIG HOLD YES USER HOLD HLD MOD PS PEAK NGPEAK Accumulation function will be automaticall disabled KILOTECH INC www kilotech com 30 12 Calibration Note 1 Before calibrate the scale you should prepare a standard weight more than 10 of FS weight for calibration 2 In following steps to press ON OFF will show EXIT and press ON OFF again or press TARE will exit calibration 12 1 Go to setup mode select CAL then press TARE to confirm to enter calibration mode
62. ur current weight CAL Spe CAL ZRO calibration zero LAST Z T switch off zero and tare j If REGULAR none the setting is DSP OVR LA5E ZE KILOTECH INC www kilotech com 10 Zero key range O no limitation 5AS5n H fey d 1 100 initial zero point 1 FS initial zero point 100 FS if REGULAR none the max is 2 Zero tracking window A 5n O Ou A 0 0d no tracking 1 100 0 2 0 05 1 100 d s if REGULAR none the max is 10 Enter digital filter1 threshold O no filter1 FLE IEH Dress HU 1 254 filter1 be used only when vibration in 0 5d 1 254 255 filter1 be always used Digital filter1 intensity f FLE ISE CN gd 1 64 ADC s data will be averaged Fi LEEr Enter digital filter2 threshold 0 no filter2 FLEGER Dag H 1 254 filter2 be used only when vibration in 0 5d 1 254 255 filter2 be always used Digital filter2 intensity TT IW FLECSE Dress el 0 255 weak to strong UEL Yes No enable disable hold function Operation refer to section 8 Hold To LE In trade application HOLD function should be prohibited Count HES YES Yes No enable disable counting function Operations SE To refer to section6 m a Percent weighing function is enable or disable 1006 1 NO disable DE rap n 2 100 enable and display format is 100 GG 10005 ne 3 100 0 enable and display format is 100 0 4 100 00 enable and display format is 100 00
63. vou d better to replace batteries When Lo bAt displayed this prompt you should replace batteries immediately otherwise it will turn off automatically in 10s 1 2 2 AC Adapter 6 9Vpc 500mA central positive tg 1 2 3 USB power supply if USB interface is installed 1 2 4 Work current lt 15mA with backlight off no optional Bluetooth Module and no load cells lt 30mA with backlight on no optional Bluetooth Module and no load cells lt 50mA with backlight on and one 350 load cell no optional Bluetooth Module 1 3 Display 6 digit 7 segment 1 25mm LCDs with 16 annunciators and blue backlight 1 4 Keypad 6 push buttons 1 5 Environment 1 5 1 Working temperature 10 C to 40 C 1 5 2 Storage temperature 20 C to 70 C 1 5 3 Humidity 10 to 90 RH without condensation 1 6 Load cell Excitation 1 6 1 Voltage 5Vdc 1 6 2 Max Current 60mA can power 4 350 ohm bridge take care the limitation when USB is power supply 1 6 3 Signal connection 4 or 6 lead with sense leads 1 6 4 Max Sensitivity 3mV V to 3mV V 1 6 5 Load cell Wiring 7 holes socket Red E PIN 1 Black E PIN 2 LOAD Green S PIN 3 connector CELL White S PIN 4 Shield PIN 5 1 7 Communication 1 7 1 Serial port1 Full duplex RS232 1 7 2 Serial port2 USB Virtual RS232 1 7 3 Optional Serial port3 Bluetooth 1 7 3 Baud Rate Selectable 1200 2400 4800 9600 19200 38400 bps 1 7 4 Data Output Format 8N1 701 7E
64. y following settings 1 USER COM1 or 2 BAUD RT 4800 2 USER COM1 or 2 BYT FMT 7E1 3 USER COM1 or 2 LAYOUT SCP 12 4 Set scale port to NCI3835 in UPS worldship KILOTECH INC www kilotech com 25 Connectors and Jumpers 25 1 Overview of Connectors or jumpers on PCB NUL LCAL K BEO 1 3 ADC E 25 2 Load Cell Connector LULU MCU UJ UCC BUZ BL ell 1 IOSEL 3 2 1 TEMP BAT BAT z BAT SIO 485B9 USBDCDG UUSBH PIN DEFINITION IN OUT POWER ELECTRICAL LEVEL 1 Excitation Power output 50 3 Vdc lt 0 12A 2 Sense Power input 5 0 3 Vde 3 Excitation Power ground OVdc 4 Sense Power input lt 0 5 Vdc 5 Signal Signal Input 2 5 0 3 Vdc 6 Signal Signal Input 2 5 0 3 Vdc 7 Shield 25 3 ADP adapter power input connector PIN DEFINITION IN OUT POWER ELECTRICAL LEVEL 1 Adapter input voltage Power input 7 9Vdc I20 5A 2 Adapter input voltage GND Power ground OVdc 25 4 BAT Battery power input Connector PIN DEFINITION IN OUT POWER ELECTRICAL LEVEL 1 Battery input voltage Power input 4 6 8Vdc 2 Battery input voltage GND Power ground OVdc 3 Temperature sensor on Battery input Power ground KILOTECH INC www kilotech com 44 J1 25 5 SIO Serial Input Output Connector