Home

Intelligent Scanner User Guide

image

Contents

1. B MAIN FEATURES e The unit is a DMX512 scanner It features full DMX512 control 10 gobos colors 71 By universal DMX controller plus open and white focus adjustable accurate optics system and stepper motor The DMX512 is widely used in intelligent lighting control with a maximum of 512 with blackout feature Fan cooled channels e It can be operated by DMX512 control or can be used as an individual unit without controller e It can be linked together as many as required in master slave mode and perform a S i DMX512 120 ohm 1 4W the great built in programmed lighting shows triggered by music COMMON e Please use a 3 pin XLR cable plug when connecting them together DMX INPUT OUTPUT e It features different pre programmed chase patterns DMX Resistance 120 ohm 1 4W between pin2 DMX an Termination reduces signal errors and to avoid signal transmission problems and interference It is always C LAMP advisable to connect a DMX terminal i e Always switch off the mains supply and never handle the lamp or luminaire when it pin3 DMX of the last fixture is hot e A DMX512 system requires a controller lighting equipment and cable These are e Do not touch the bulb with bare hands If this does happen clean the lamp with sp connected together in a daisy chain with the terminator at the end The cable denatured alcohol and wipe with a lint free cloth before installing
2. cannot be branched or split to a Y cable e The terminator requires a 90 120 Ohm 1 4 Watt resistor soldered between two 3900 1000 525 lux i signal cables MH 635 ee F once e The DMX512 uses a very high speed signal Inadequate or damaged cables bad ie solder joints or corroded connectors can easily distort the signal and shut down ap M Ganee the system A reliable DMX512 system starts with good quality cables 130l iuas EPA e Each lighting unit needs to have an address set to receive the data sent by the MH 635B 2 controller The address number is between 0 511 The end of the DMX512 system should be terminated reducing signal errors 0 Sti e 3 pin XLR connectors are more popular than 5 pin XLR ae ape OOO as 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal i 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal MH 635S p g gnal gnal Distance m
3. EX A GENERAL INSTRUCTIONS B MAIN FEATURES C LAMP D HOW TO CONTROL THE UNIT 1 By universal DMX controller 2 Preprogrammed function 3 By easy controller E FIXTURE CLEANING 3D 2 Preprogram functions The unit can be linked together in daisy chain as many as you need in master slave mode to perform the great built in pre programmed lighting shows triggered by music In Master Slave mode refer to the DMX settings below Master unit DMX start address MUST be set to 001 first DIP switch ON all other are OFF Slave units DMX start address may have any value but NOT 001 example set the first 3 DIP switches to ON x 2 light show Dipswitch 10 off means the unit works normally and on means inversion In order to create a great light show you can set dip switch 10 on on any unit that is linking to the master unit to get contrast movement to the master unit even if you have two units only Dipswitch 10 on the first Master unit is no use for the 2 light show as it is the master unit that operates the light show 3 By easy controller The easy remote control is used only in master slave mode By connecting to the 1 4 microphone jack of the first unit its DMX input plug is not used you will find that the remote control on the first unit will control all the other units for Stand by Function and Mode fbb gael Sanne j Controller Built in lighting shows tr
4. Technical Specifications Intelligent Scanner Mhe Messe MH 695s AC 230 250V 50Hz Professional Lighting Technology T5A T3 15A T6 3A T5A T6 3A T5A EFP 12V 100W ELC 24V 250W ELC 24V 250W Dimension 385x170x122mm 405x170x122mm 385x170x122mm Weight 3 8kg 4 5kg 4 5kg LINKABLE STAND ALONE User Guide Please read the instructions carefully before use E FIXTURE CLEANING The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with a soft cloth using normal glass cleaning products Always dry the parts carefully Clean the external optics at least once every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 amp Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements IND
5. environment Please dispose of the packing boxes properly fo Jick he en B o io The electrical work that is necessary for installation must done by qualified personnel e Start the address e Always remember to unplug the unit from the main power before any service is How to address your DMX512 system done Do not open the unit There are no serviceable parts inside 1 Select the channels of DMX controller e It is very important to ground the yellow green conductor to earth in order to meet 2 Dipswitches regulations for safety Dp Jan ve ws m l as a7 ao e Check the surrounding area and make sure there are no flammable liquids water or Value 1 2 4 8 16 32 64 128 256 metal objects that could enter the fixture If a foreign object enters the unit e Examples immediately disconnect the main power Also place the fixture in a well ventilated Channel 01 dip on 1 1 room at about 15 cm from the walls Channel 05 dip on 1 3 1 4 5 e Do not touch any wires during operation as high voltage is hazardous Channel 09 dip on 1 4 1 8 9 e In the event of serious operating problems stop using the unit immediately Never Channel 13 dip on 1 3 4 1 4 8 13 try to repair the unit yourself Repairs carried out by unqualified personnel can lead to damage or malfunction Please contact the nearest authorized Technical Assistance Center Always use genuine spare parts D HOW TO CONTROL THE UNIT
6. iggered by Easy Controller Stand by Blackout the unit Function Strobe X Y moving pattern Color Gobo selection 1 sync strobe selection 2 two light strobe 12 patterns Mode Strobe Sound Pattern Sound Sound LED off LED blinking LED on CHANNEL 1 CHANNEL AAA aoe cena CHANNEL 4 A GENERAL INSTRUCTIONS PAN a SHUTTER GOBO an ia a 255 Fastest speed Gobo change A Please read the enclosed instructions carefully as they include important Rot CRE amp l O 132 247 shaking 128 Slowest speed Gobo change WARNING points about safety for the installation usage and maintenance of the unit an e Please keep this booklet with the unit for future consultation If you sell the unit to 105 116 Blue Magenta 131 Fastest speed shutter dy another user be sure that the new user also receives this instruction booklet thus 4 094 104 Red dy giving them the necessary information about the use and general warnings 082 093 M j i agenta regarding the unit OF0 081 Red Yellow Green Blue Ay 059 068 Pink 16 Slowest speed shutter e Before the initial start up please unpack and carefully check all components in case any damage may have occurred during shipping ee ee e Locate a suitable spot for your device where there is good ventilation Also make 035 046 Blue Red Green sure that no ventilating fans or slots are blocked zk O x 3 ee 2 aa O eee e Protect our