Home

TWENTY RELAY OUTPUT CHANNELS

image

Contents

1. IMPORTANT When operating with the RP501 transmitter in radio relay mode as well as with wireless detectors CTX3H or CTX4H exclusively used output channel s operating mode should be set to pulse time mode pt 1 above Despite of that output s set on off timing will match on off timing of the transmitters Low Battery Warning Detected low battery in transmitter operating with CH20HR receiver is warned by blinking front panel LED marked LOW BATTERY INDIC and if jumper JP2 is set OFF see jumpers description setting on of output S To find out the output channel with low battery transmitter il luminated button marked LOW BATTERY CH must be pressed and all outputs with low battery will be LED illuminated Replacing battery sets off low battery warning RF Link with Detector Failure Warning CH20HR receiver features detection of radio link failures when operat ing with wireless detectors PTX GNS GBX amp CTX4H The detectors send supervisory transmission every 10 hours If within 24 hours peri od transmission is not received from a detector e g due to its tech nical failure the receiver will indicate that by pulsing LOW BATTERY INDIC LED and if jumper JP2 is off setting on signaling output S However when LOW BATTERY CH button is pressed relays and LEDs in channels with RF link failure will start pulsing as contrary to steady LED shining in the case of low battery detectors indication Any radio transmission received
2. from detector with RF link failure clears the failure warning To activate RF link failure warning JP3 should be set OFF after completing installation and learning all detectors followed by forcing every detector to send a transmission The procedure should be taken on every change in wireless detectors configuration with the receiver deleting detector or moving detector to other channel Jump er JP3 should be set ON for a while and then OFF followed by detec tors activation in order to initialize the function Elmes Electronic 11 2014 CH20HR TWENTY RELAY OUTPUT CHANNELS HOPPING CODE RECEIVER IMPORTANT Proper functioning of low battery and RF link failure warnings require that only one wireless detector operates in one re ceiver s channel Radio Jamming Sabotage Warning CH20HR receiver features anti sabotage function of detecting deliber ate or incidental radio frequency jamming If RF jamming is detected receiver output 19 is set on for as long as the jamming lasts The func tion is active when JP5 is set OFF Jumpers JP1 JP5 description JP1 set ON output S generates pulses on any output channel set on and off set OFF output S generates pulses on channel 1 output set on and off only JP2 set ON output S signals channel set on and off see outputs operating modes and description of JP1 above set OFF output S signals low battery in detector and if JP3 is set OFF RF link failure JP3 set
3. 00 further referred to as re motes for system remote arming and disarming designing alert call in system or wireless panic button where personnel is equipped with remotes e g AN200H or UMB100H and can activate call in request or activate panic alarm for help Receiver s outputs operation modes Activation of transmitter programmed to the receiver results in setting its channel relay output ON and illuminating channel s LED indicator Output relays SET ON timing depends on one of three operation modes described below individually programmed to each output chan nel 1 Temporary pulse set on mode lasting from 0 5s up to 4h Signal output S generates two pulses on any relay set and one pulse on reset See programming pt 2 2 Latching on off bistable mode activated by consecutive signals received from transmitter Signal output S operates as above 3 Temporary pulse set on mode lasting until reset is made by pressing the front panel LOW BATTERY CH button elsewhere re ferred to as LBC switch For as long as output relay is set on sig nal output S generates pulses lasting 0 5s every 0 5s interval Pressing the LBC switch resets relay output and stops signaling at output S This operation mode enables designing intervention call system with call clearance made up by personnel authorized to use LBC button of the receiver To enable this mode jumper JP4 of the receiver must be set OFF see description of jumpers
4. ON RF link supervision with wireless detectors set OFF set OFF RF link supervision with wireless detectors set ON JP4 setON selects standard operating mode with outputs in pulse or latched mode as in pts 1 amp 2 above set OFF receiver in call in operating mode as described in pt 3 of outputs operating modes JP5 set ON RF jamming detection function set OFF set OFF RF jamming detection function set ON Installation and Outputs Settings Receiver CH20HR operates indoors only with ambient temperature range 20 to 55 C Installation place should be dry possibly high and far from electromagnetic power lines radio transmitters metal screen ing and devices that may cause interference reducing operation range Wire antenna should be let loose downwards and must not be glued to wall Practical tests should be taken prior to firm installation of the re ceiver and transmitters to determine exact operation range Factory outputs setting is NC normally closed Setting relay outputs to NO is made by solder joints made for each relay on pc board soldering side Disconnecting receiver s power supply or opening its case sets off out put channel 20 indicating sabotage alarm TAMPER ALARM Power supplay 12V 750mA Relay s outputs Buzzer 12V solder vol CH20H Wiring diagram Receiver s board PROGRAMMING PROCEDURES Programming is performed with front panel taken off and the use of programming switches PRG sma
5. d by fast blinking PRG LED If no programming steps are made for more than 16s the receiver sets off programming mode Specification power supply 11 to 15VDC nominal 12VDC current draw 35mA plus 23mA on every relay set on 500mA max 20 channel relay NC or NO outputs rated 1A 24VDC 0 5A 125VDC each channel output state LED indication open collector signaling output S rated 1A 60VDC max super heterodyne 433 92MHz band receiver up to 60 code hopping transmitters wireless detectors and key fobs memory receiver s box anti sabotage switch TAMPER strictly indoor installation operation within ambient temperatures 20 to 55 C operating range depending on installation environment and type of used transmitter Manufacturer ELMES ELECTRONIC 54 611 Wroclaw Poland ul Avicenny 2 tel 48 717845961 fax 48 717845963 Elmes Electronic 11 2014 ag Manufacturer s Limited Warranty This product carries two years manufacturers warranty as from the date of purchase The warranty is limited to the replacement of faulty Original parts or repair defects of improper manufacture Damage faulty use or improper handling by the user or installer as well as any chang es in product s hardware or software caused by the user violets the warranty and all due repair costs will be charged Elmes Electronic shall not bear liability for any personal or material damage resulting from any of its
6. elmes electronic This microprocessor controlled 20 output channels receiver is designed to operate with up to 60 transmitters in remote control wireless alarms and access control systems It features transmitters KEELOQ code hopping verification system allowing highest level of security The re ceiver provides 20 galvanic separated NC NO relay outputs each with front panel LED indication Other features include transmitter s low bat tery warning indication and in operation with selected transmitters radio communication link failure and transmitter s case sabotage opening sig naling The receiver operates with all Elmes Electronic made 434MHz band transmitters Each receiver channel may have pre programmed any number of Elmes transmitters with total number operating with one CH20HR receiver not exceeding 60 Next transmitter learned will delete the first in receiver s memory Multi channel hand transmitters and RP501 transmitter learned to the receiver always control consecutive adjacent channels Wireless detectors PTX50 GBX GNS CTX3H and CTX4H operate in two output channels of the receiver alarm detection signaled in any channel 1 20 and sabotage detection TAMPER signaled in channel 20 assigned au tomatically Typical application fields of CH20H receiver include interfacing any wired control panel with wireless Elmes made de tectors and transmitters such as CTX GBX PTX and RP501 as well as hand held transmitters e g UMB1
7. il elmes elmes pl
8. ll switch with PRG marked on pcb and LBC front panel illuminated switch marked LOW BATTERY CH Programming stages are indicated by red LED in middle top section of the receiver 1 Learning transmitter s wireless detectors or key fobs to re ceiver s memory maximum 60 follow steps as below a Press shortly receiver s PRG switch The PRG LED switches off and on and the first channel indication LED illuminates b By shortly pressing the PRG switch select the required channel for learning transmitter c Shortly press the LBC switch the LED will switch off d Depending on type of programmed transmitter proceed with next step as follows hand transmitters key fobs double press the transmitter s but ton as in example 1 respective to required control channels PTX50 GBX GNS detectors activate RF transmissions accord ing to instructions in their manuals see also example 2 CTX3H CTX4H wireless detectors actuate two transmissions by double moving magnet in and out of case reed relay side or opening door window if installed RP501 transmitter set the required mode of operation in trans mitter radio link testing mode not allowed connect all inputs to www elmes pl email elmes elmes pl ground and actuate transmission by disconnecting one of the in puts as in example 3 respective to required control channels e Slow blinking LED in the receiver indicates end of the procedure Examples 1 Lea
9. products direct indirect or partial failure to operate properly C DECLARATION OF CONFORMITY Manufacturer Elmes Elektronik declares under sole responsibility that product RECEIVER CH20HR complies with essential requirements of the following directives 1999 5 EC Telecommunication Directive R amp TTE 2004 108 EC Electromagnetic Compatibility Directive EMC 2006 95 EC Low Voltage Directive LVD and applied harmonized standards in particular EN 60950 1 2006 electric safety EN 61000 6 1 2007 EMC immunity EN 61000 6 3 2007 EMC emission EN 301 489 1 V1 8 1 2008 04 EMC radio devices EN 301 489 3 V1 4 1 2002 08 EMC short range devices SRD EN 300 220 1 V2 3 1 2010 02 EMC radio requirements ERM Manufacturer ELMES ELEKTRONIK ul Avicenny 2 54 611 Wroc aw Poland tel 48 717845961 fax 48 717845963 elmes electronic SIENATUTE sanrenkpen nai Ea Director Miros aw Binkowski Date 2014 11 27 IMPORTANT The use of above symbol indicates that this product should not be treated as household waste By ensur ing this product is disposed of correctly you will protect the environment For detailed information about recycling of this product please contact your local authority your household waste disposal service provider or organization the product has been purchased from LEAD FREE This product has been manufactured in lead free technology www elmes pl ema
10. rning control button 4 green of four channel keyfob transmit ter CH4H to output channel 8 of CH20H receiver would automati cally learn the remaining keyfob control buttons 1 2 amp 3 to chan nels 5 6 amp 7 of the receiver 2 Learning wireless motion detector PTX50 to output channel 3 of CH20H receiver results by motion detection signaled in channel 3 while detector s sabotage case opening signaled in channel 20 3 Learning transmitter RP501 inputs 1 amp 2 to CH20H receiver out put channels 11 amp 12 respectively output channel 12 should be se lected as in pt 1b above in the receiver and input 2 of the trans mitter should be actuated decoupled As result inputs 1 amp 2 of RP501 transmitter would control outputs 11 amp 12 of CH20H receiv er Inputs 3 amp 4 of the transmitter are not used 2 Programming receiver s any output channel s momentary set on time monostable mode a Press amp hold receiver s PRG switch longer than 2 and less than 8 seconds until LED sets on b Shortly pressing the PRG switch select required channel for pro gramming momentary output s set on time c Shortly press the LBC switch and the LED sets off d Shortly press PRG switch again the LED sets on and the count of output momentary set on time starts When desired set on time has lapsed up to 4 hours press the PRG switch again End of correctly performed procedure is indicated by blinking LED 3 Programming receiver s an
11. y output channel s on off operating mode latched bistable mode a Repeat programming steps 2a 2b amp 2c as above b Shortly press PRG switch three times with less than two seconds intervals End of correctly performed procedure is indicated by blinking LED 4 Deleting all transmitters from receiver s memory Press receiver s PRG switch until programming LED starts blinking longer than 8 seconds and then release the switch Receiver s memory is cleared but the output channels programmed modes of operation remain unchanged To learn new transmitter s follow procedure pt 1 above 5 Deleting single transmitter from receiver s memory Except for RP501 transmitter it is possible to delete any other sin gle transmitter key fob or wireless detector from receivers memory under condition that the transmitter to be deleted is in our possession This procedure requires performing steps a b amp c of learning procedure pt 1 above with two succeeding transmissions at step 1 d to be performed in the following way first transmission must be sent from the transmitter to be deleted and second trans mission from any other transmitter e g by pressing other button in multi channel hand held transmitters Receivers LED blinking red will indicate programming error in this case meaning that the transmitter is deleted The receiver will not respond any more to signals sent from deleted transmitter NOTE programming errors are indicate