1. 15 10 50 17 85 4 20 11 55 18 90 5 25 12 60 19 95 6 30 13 65 20 100 7 35 14 70 21 200 Dwell Flickering Green Values 5 30 Default is 12 Dwell is the amount of time that the solenoid will be activated The default is 12 milliseconds ms and the values range from 5 30 ms Too low of a dwell setting will lead to inconsistent velocities and drop off Too high of a dwell will result in poor air efficiency Eye Sensitivity Flickering Red Values 1 50 Default is 5 The Eye Sensitivity setting adds a small delay after the eye has seen a ball before it allows the marker to shoot Players using non force fed loaders may need to raise this setting to prevent chopping The default setting is 5 with 1 being the fastest No delay AMB Flashing Blue Values 1 10 Default is 3 The Anti Mechanical Bounce AMB feature allows the user to adjust for mechanical bounce Mechanical bounce happens when the kick from having a shot fired causes the marker to shoot additional shots after the trigger has been pulled The default setting is 3 which is alow AMB This setting ranges from 1 10 with 1 being AMB off ABS Flashing Green Values 1 20 Default is 10 The Anti Bolt Stick ABS setting is the amount of dwell time added for an ABS shot This setting ranges from 20 additional milliseconds of dwell with the default set to 10 Max Rate of Fire Flashing Red Values 1 22 Default 1 The max rate of fire
2. programming mode hold the trigger down for 10 seconds until the LED turns blue After the LED turns blue it will then flash through the rainbow of colors indicating that all settings have been returned to the factory default Adjustable Settings Firing Mode Blue Values 1 7 Default is 1 1 Semi Auto Semi Automatic Fire trigger pull equals 1 shot 2 PSP Ramping The first 3 shots of a string are Semi Auto After the 4 shot the marker will ramp to the rate of fire your Max Rate of Fire is set to Once the trigger is let go and 1 second elapses the 3 shot Semi Auto count restarts 3 NXL Style Full Auto The first 3 shots of a string are Semi Auto On the 4th shot you can then hold down the trigger and the marker will shoot full auto at your Max Rate of Fire Once the trigger is let go and 1 second elapses the 3 shot Semi Auto count restarts 4 Ramp Mode When you reach the Ramp Activation Speed the Marker will ramp the rate of fire by your Ramp Percentage setting up to your Max Rate of Fire Factory default is when your trigger speed reaches 5bps the marker will ramp up to the maximum speed that your loader can feed 5 Auto Response shot on the pull of the trigger 1 shot on the release This setting will make you shoot twice as fast as you can pull the trigger 6 Full Auto Hold down the trigger and the marker will fire at your max rate of fire or as fast as your loader can feed 7 Breakout M
3. This manual provides installation and operating instructions for the AdvantagePB Virtue Shocker Nerve Upgrade Board Features e 7 Modes of fire Semi Auto Modified PSP NXL NXL Style Full Auto Ramp Mode Auto Response Full Auto and Breakout Mode e 15BPS Ready Be ready for any tournament series Put Dipswitch 1 in the off position and your maximum rate of fire is capped at 15bps e All firing modes have user adjustable maximum rates of fire from 10 50bps to unlimited rates of fire e AdvantagePB Trigger Logic constantly monitors the trigger to ensure every trigger pull is recognized giving you the fastest responding gun and highest possible rates of fire e Adjustable Debounce Dwell Anti Mechanical Bounce AMB Eye Sensitivity Ramp Activation Speed Ramp Percentage and Anti Bolt Stick ABS e Power Efficient Software extends the life of your battery e All settings are stored in non volatile memory so they will not be lost when the battery dies or is removed e 10 minute idle auto shutdown saves battery life e Forced Shot allows the marker to be fired when the eyes are enabled but no object is in the breech e Instant On allows the marker to be fired instantly upon turn on e Tournament Lock Unlock allows the marker to be programmed through the trigger without having to constantly open the grip With the tournament lock enabled settings cannot be changed without opening up the grip Installing Y
4. f Fire Purple LED Options To Change the Value of a Setting When the LED is lit for the desired setting pull and hold the trigger until the LED Begins to flash The LED will flash the number of times the current value is set to When the LED stops flashing you then have 2 seconds to enter in the new value by tapping the trigger the amount of times you want the new value to be set to After you have set the new value the LED will flash back at you the number of times you have just entered and then flash through the rainbow of colors returning to the color you have just adjusted indicating that the new value has been set To exit programming mode shut the marker off Programming Example If you want to change the debounce to 2 you would 1 With the marker off and Dipswitch 2 in the on position hold the trigger and turn the marker on 2 The multi color LED will now cycle through a rainbow of colors and stop on Blue Tap the trigger once so the LED glows green 4 Pull and hold the trigger until the LED starts to flash factory default for debounce is 5 so the LED will flash 5 times 5 When the LED stops flashing quickly tap the trigger 2 times 6 The LED will now flash 2 times and then flash through the rainbow of colors and stop on green indicating the new value has been set 7 To exit program mode shut the marker off Go Reset to Factory Default To return all settings to the factory defaults while in
5. ode In this mode when you turn the gun on the first shot will shoot full auto for as long as you hold down the trigger Once you release the trigger the gun goes into Ramp Mode If you turn your marker off and back on when in this mode the Breakout function will repeat Debounce Green Values 1 30 Default is 5 Debounce is the amount of time that the trigger has to be released before the next trigger pull is allowed Virtue software incorporates our own AdvantagePB debounce algorithm which ensures every trigger pull is recognized This results in giving the user the highest rates of fire possible The values range from 1 50 with the default set to 5 Ramp Activation Speed Red Values 5 15 Default is 5 The ramp activation speed setting only affects Firing modes 4 and 7 Ramp and Breakout Mode The default setting is 5 which means when the user reaches triggers speeds of Sbps ramping will activate and add the percentage set in the Ramp Percentage setting The values of this setting are equivalent to balls per second For example 5 Sbps 10 10bps etc Ramp Percentage Flickering Blue Values 1 21 Default 1 The ramp percentage setting only affects Firing modes 4 and 7 Ramp and Breakout Mode The default setting is 1 which Maxes Your Loader as soon as the Ramp Activation Speed is reached Valu Percentag Valu Percentag Valu Percentag e e e e e e 1 Max Loader 8 40 15 75 2 10 9 45 16 80 3
6. ode of the Virtue Shocker Nerve Board Dipswitch 2 must be in the on position Then hold down the trigger and turn the marker on to enter programming mode When Dipswitch 2 is in the off position the gun is in Tournament Lock and program settings cannot be changed LED Indicator The power button on the back of the marker also functions as a small blue LED telling you the status of your marker Solid Blue Eye Enabled Ball in Breech Flickering Blue Eye Enabled No Ball in Breech Fast Flashing Blue Eye Disabled Flashing Blue Eye Malfunction In addition the multi color led on the board will also tell you the status of your gun Solid Blue Eye Enabled Ball in Breech Solid Red Eye Enabled No Ball in Breech Flashing Red Eyes Disabled Flashing Blue Eye Malfunction If you do not wish to use the multicolor LED during play it can be turned off through the programming menu Power Operation The Virtue Shocker Nerve Board uses Instant On technology Simply tap the power button and the marker instantly turns on and is ready to fire When the marker is turned on the eye is automatically enabled To turn the marker off at any time press the power button for 2 seconds Eye Operation When the marker is turned on the eye system is automatically enabled The eyes can be turned off by pressing the power button for 1 second When the eyes are disabled the max rate of fire will not go over 20bps The eye logic differentiate
7. our AdvantagePB Shocker Nerve Board 1 With the grip frame open push out the two pins that are holding in your existing board 2 Remove the battery from the wiring harness being careful not to damage the wires 3 Carefully remove your existing board from the marker and disconnect the wire harness from your existing board 4 Connect that same wire harness to the AdvantagePB Virtue Shocker Nerve Board 5 Place the Virtue Shocker Nerve board back into the grip frame making sure the bottom of the board is in the slot of the grip frame 6 Line up the two pins you removed in step 1 and push them back into place 7 Last reconnect the battery and close the grips Setting the Dipswitches On the AdvantagePB Shocker Nerve Board there is a 2 position dipswitch Dipswitch 1 is the Max Rate of Fire 15bps Cap lock If Dipswitch 1 is in the on position your max rate of fire is set to your Max Rate of Fire setting Flashing Red LED in programming mode If dipswitch 1 is in the off position the Max Rate of Fire of all modes is capped at 15bps After changing this setting you must turn the marker off before it takes effect Please note the actual bps will vary slightly from gun to gun If the desired bps is too high or too low with dipswitch 1 off then leave Dipswitch 1 in the on position and adjust the max rate of fire setting through the programming menu Dipswitch 2 is the Tournament Lock To access the programming m
8. s between a ball being fired and something continually blocking the eye like your finger If the eye becomes blocked both LED s if enabled will flash blue indicating an eye malfunction When the object blocking the eyes is removed the eye will automatically return to working mode Programming Mode To access the programming mode of the Virtue Shocker Nerve Board Dipswitch 2 must be in the on position When Dipswitch 2 is in the off position the gun is in Tournament Lock and program settings cannot be changed With Dipswitch 2 in the on position hold the trigger and turn the marker on The multi color LED on the board will then cycle through a rainbow of colors and stop on blue indicating that you are now in programming mode The small blue LED on the back of the gun will also indicate going into programming mode by flashing and flickering blue then stopping on blue When adjusting the mode of fire the small blue LED can be used This is very useful for changing firing modes on the fly To adjust any other setting you must use the multicolor LED as the small blue LED will go out Tapping the trigger will then toggle through the different programming modes Blue Firing Mode Green Debounce Red Ramp Activation Speed Flickering Blue Ramp Percentage Flickering Green Dwell Flickering Red Eye Sensitivity Flashing Blue AMB Anti Mechanical Bounce Flashing Green ABS Anti Bolt Stick Flashing Red Max Rate o
9. setting applies to all modes of fire If Dipswitch 1 is in the up or on position the max rate of fire is determined by this setting If Dipswitch 1 is in the down or off position the rate of fire is capped at 15bps for all modes of fire The max rate of fire is adjustable from 10 5bps to unlimited rates of fire The default setting is 1 which is an unlimited rate of fire Value BPS Value BPS Value BPS l Unlimited 10 14 50 19 19 00 2 10 50 11 15 00 20 20 00 3 11 00 12 15 50 21 21 00 4 11 50 13 16 00 22 22 00 5 12 00 14 16 50 6 12 50 15 17 00 7 13 00 16 17 50 8 13 50 17 18 00 9 14 00 18 18 50 LED Options Purple Values 1 3 Default is 1 The LED Options setting allows the user to choose if the mult icolor LED on the board is active outside of the programming menu In addition it allows users to only use the multi color LED if desired making the small blue LED simply a power button The default setting is 1 which uses both LED s If you do not wish to use the Multicolor LED you should shut it off to conserve battery life Value LED Options 1 Both LED s 2 Small Blue LED Only 3 Multi color LED Only For More Information Please See www AdvantagePB com 103 Fulton Blvd Commack NY 11725 Specifications subject to change without notice Shocker Nerve Board User s Manual