1. Stride 1 800 633 0405 VAUTOMATIONDIRECT 3505 HUTCHINSON ROAD CUMMING GA 30040 5860 USA STRIDE INDUSTRIAL UNMANAGED ETHERNET SWITCH 5 PORT DATA SHEET YAUTOMATIONDIRE T gt Power e AUTOMATION T Power e DIRECT l Rel I ma L ronl SE SW5U SE SW5U WT Metal case designed for 40 to 85 C Description STRIDE SlimLine Industrial Unmanaged Ethernet Switch with five 10 100BaseT RJ45 Ethernet ports Redundant power inputs with surge and spike protection Auto crossover DIN rail mounting Supports store amp forward wire speed switching and full duplex with flow control UL CSA CUL amp CE The WT models have a metal case and are rated for a wider temperature range from 40 to 85 C NOTE DIMENSIONS INSTALLATION AND WIRING INFORMATION IS SHOWN ON THE BACK OF THIS DATA SHEET Copper RJ45 Ports 10 100BaseT 10 100BaseT ports Shielded RJ45 Protocols supported All standard IEEE 802 3 Ethernet compliancy IEEE 802 3 802 3u 802 3x Auto crossover Yes allows you to use straight through or crossover wired cables Auto sensing operation Yes Full and half duplex Auto negotiating Yes 10BaseT and 100BaseT Auto polarity Yes on the TD and RD pair Flow control Automatic Ethernet isolation 1500 VRMS 1 minute Plug and play Yes Cable requirements Twisted pair Cat 5 or better shielded recommended M
2. ax cable distance 100 meters NOTE FOR ADDITONAL PRODUCT DETAILS SE USER M IS AVAILABLE AS A DOWNLAODABLE PDF FILE FROM THE ONLINE DOCUMENTATION AREA OF THE AUTOMATIONDIRECT WEBSITE A USER MANUAL Ethernet switch type General Specifications 5 ports Operating mode Store and forward wire speed switching non blocking Devices supported All IEEE 802 3 compliant devices are supported Standards IEEE 802 3 802 3u 802 3x MAC addresses 1024 addresses Memory bandwidth 3 2 Gbps Latency for 10 Mbps ports 16 us frame time typical Latency for 100 Mbps ports 5 us frame time typical Power input Redundant Input Terminals Input power typical with all ports active at 100 Mbps 2 0 W Input voltage 10 30 VDC continuous Class 2 Power Supply Reverse power protection Yes Transient protection 15 000 watts peak Spike protection 5 000 watts 10x for 10 uS Ethernet isolation 1500 VRMS 1 minute Operating temperature range SE SW5U 10 to 60 C 14 to 140 F cold startup at 10 C 14 SE SW5SU WT 40 to 85 C 40 to 185 F cold startup at 40 C 40 F Storage temperature range 40 to 85 C 40 to 185 F Humidity non condensing 5 to 95 RH Environmental Air WODI PJIAIIGQUOIZJEWOINY NMMM No corrosive gasses permitted Vibration shoc
3. dangereux seulement AVERTISSEMENT RISQUE D EXPLOSION LA SUBSTITUTION DE TOUT COMPOSANT PEUT NUIRE A LA CONFORMIT DE CLASSE I DIVISION 2 AVERTISSEMENT RISQUE D EXPLOSION LORSQUE DANS DES ENDROITS DANGEREUX DEBRANCHEZ LE CORDON D ALIMENTATION AVANT DE REMPLACER OU DE BRANCHER LES MODULES AVERTISSEMENT RISQUE D AVERTISSEMENT NE DEBRANCHEZ PAS L QUIPEMENT PENDANT QUE LE CIRCUIT EST DIRECT OU A MOINS QUE L ENVIRONNEMENT SOIT CONNU POUR ETRE LIBRE DE CONCENTRATIONS INFLAMMABLES AVERTISSEMENT RISQUE D EXPLOSION DANS LES ENDROITS DANGEREUX OU POTENTIELLEMENT DANGEREUX NE PAS SEPARER UNE PARTIE DE L UNITE SOUS TENSION SEULEMENT UTILISEZ L APPAREIL POUR LES CONNEXIONS INTERNES Tout pouvoir le c blage d entr e et de sortie 1 0 doivent tre conformes aux m thodes de c blage de Classe I Division 2 et conform ment a l autorit comp tente Copyright 2014 AutomationDirect com Incorporated All Rights Reserved Worldwide 2 5 Port SE SW5U WT Removable 0 30 Snaps to standard 0 175 pant 7 6 35mm x 7 5 mm height DIN rail EN50022 4 4 paie 17570385 pn digs al TK fo 2 25 Dia 0 175 4 4 ey Use for direct panel mounting to 4 00 4 35 a flat surface with 101 6 110 5 up to 8 screw Removable 2 25 for direct panel 57 1 mounting 0 39 9 9 Units inches mm Power Wiring The switch can be powered from the sa
4. ied to the metal connector body at one end of the cable only Electrical isolation is also provided on the Ethernet ports for increased reliability Additional Help and Support For additional product support specifications and installation a User Manual SE USER M is available as a downloadable PDF file from the Online Documentation area of www AutomationDirect com e For additional technical support and questions call our Technical Support team 770 844 4200 WODI PFIALIGQUOIZJEWOINY NMMM
5. k amp freefall IEC68 2 6 27 32 Electrical safety UL508 CSA C22 EN61010 1 file 200031 EMI emissions FCC part 15 ICES 003 EN55022 EMC immunity IEC61326 1 Agency Approvals UL cUL 508 CSA C22 per EN61010 1 UL cUL 1604 Class 1 Div 2 Groups A B C D CSA C 22 2 213 9 per EN50021 EN60079 15 Zone 2 Category 3 CE ATEX RoHS and WEEE RoHS Pb free and WEEE compliant Packaging and protection SE SW5U UL94VO Lexan IP30 SE SW5U WT Aluminum IP30 Dimensions L x W x H See mechanical diagrams for details Weight SE SW5U 4 oz 0 11 kg Safety Standards c UL us Electrical Safety SE SW5U WT CE 6 oz 0 17 kg FC European mae Directives US Emissions RoHS RoHS Compliant WEEE Compliant 1 800 633 0405 Dimensions 5 Port SE SW5U Removable Screw Block Phoenix n 1757035 Snaps to standard p n 35 mm x 7 5 mm height DIN rail EN50022 5 1 01 25 7 1 98 50 3 4 35 Dia 0 15 3 8 3 96 110 5 Use for direct 100 6 panel mounting o a flat surface E i 50 3 01 25 7 1 00 3 26 LL 0 06 25 4 T g 82 8 1 5 Units inches mm Installation DIN Rail Mounting The switch can be snapped onto a standard 35 mm x 7 5 mm height DIN rail Standard CENELEC EN50022 and can be mounted either vertically or horizontally DIN rail mou
6. me DC source that is used to power your other devices To maintain the UL508 listing this must be a Class 2 power supply A DC voltage in the range of 10 to 30 VDC needs to be applied between the P1 plus terminal and the Minus terminal as shown below The chassis screw terminal should be tied to panel or chassis ground To reduce down time resulting from power loss the switch can be powered redundantly with a second power supply as shown below A recommended DC power supply is AutomationDirect com Part number PSC 24 015 Redundant DC Power Maximum power terminal screw torque is 5 0 Ib in 0 57Nm Single DC Power Wire Size Range 24 12 AWG Chassis GND panel 10 30 VDC 2 0W Communication Ports Wiring Chassis GND panel One DC Supply Dual DC Supplies The switch provides connections to standard Ethernet devices such as PLCs Ethernet I O industrial computers and much more Use data quality not voice quality twisted pair cable rated category 5 or better with standard RJ45 connectors Straight through or crossover RJ45 cable can be used for all devices the switch is connected to as all the ports are capable of auto mdi mdix crossover detection The RJ45 Ethernet port connector bodies on the switch are metallic and connected to the Chassis GND terminal Therefore shielded cables may be used to provide further protection To prevent ground loops the cable shield should be t
7. nting steps plastic and metal case 1 Hook top back of unit over the DIN rail 2 Push bottom back onto the DIN rail until it snaps into place DIN rail removal steps plastic case A Insert screwdriver into DIN clip and pry until it releases from the rail B Unhook top of unit from DIN rail DIN rail removal steps metal case A Push the unit down to free the bottom of the DIN rail B Rotate the bottom of the unit away from the DIN rail C Unhook top of unit from DIN rail Removal plastic case Removal metal case Mounting All power input and output 1 0 wiring must be in accordance with Class I Division 2 wiring methods and in accordance with the authority having jurisdiction This Equipment is Suitable for Use in Class I Division 2 Groups A B C D or Non Hazardous Locations Only A WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIVISION 2 WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS DISCONNECT POWER BEFORE REPLACING OR WIRING UNITS WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS WARNING EXPLOSION HAZARD IN HAZARDOUS OR POTENTIALLY HAZARDOUS LOCATIONS DO NOT SEPARATE ANY PART OF THE UNIT WHEN ENERGIZED USE THE UNIT FOR INTERNAL CONNECTIONS ONLY A Cet quipement est adapt pour une utilisation en Classe1 Division 2 Groupes A B C et D ou endroits non
Download Pdf Manuals
Related Search
Related Contents
"user manual" ELECTIONS COMMUNALES 2012CONTACT.DOC TENDER DOCUMENT - STATE HEALTH SOCIETY BIHAR UN GESTE Smeg KAB45-1 Instruction Manual LRP Crawler Brushless Reverse ESC Manual PEAKS Studio Manual 2.0 - Bioinformatics Solutions Inc. COMPLEXE de NOYER NOIR HP 11744195 User's Manual クランプ式電流プローブ MODEL 8112 取扱説明書 特 長 仕 様 測定方法 Copyright © All rights reserved.