Home
        1. Package Content 2. Requirements 3. Start Web Management
         Contents
1.             ps 45   UTP Cable  am     The following shows how to startup the Web Management  of the PoE Injector Hub  please note the PoE Injector Hub is  configured through an Ethernet connection  make sure the  manager PC must be set on the same IP subnet address   for example  the default IP address of the PoE Injector Hub    E       is 192 168 0 100  the factory default IP address   then  the manager PC should be set at 192 168 0 x  where x is  a number between 1 and 254  except 100   and the default  subnet mask is 255 255 255 0     Use Internet Explorer 5 0 or above Web browser  enter  default IP address http   192 168 0 100    To access the Web interface then the Web login screen  appears in Figure 1    Default IP Address  192 168 0 100  Default Account  admin  Default Password  admin    The following screen based on POE 2400P4   for POE 1200   POE 1200P2   POE 2400 the  display will be the same to POE 2400P4      D PLANET    POE 2400P4    IEEE 802 3af Power over Ethernet Injector Hub Web Interface  Username sJadmin  Password     Login    Copyright    2008 PLANET Technology Corporation  All rights reserved        T m    Figure 1  Web Login Screen of POE 2400P4      e    After entering the user name and password  default user  name and password is    admin     in login screen  Figure 1  appears   The Web main screen appears as Figure 2     D PLANET  POE 2400P4    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24     OE 2400P4 wn  onting  amp  Commentcation 
2.    Thank you for purchasing PLANET 12 24 Port Web Smart  PoE Injector Hub  POE 1200   POE 1200P2   POE 2400    POE 2400P4  Terms of    PoE Injector Hub    in following  section of this Quick installation guide means the POE 1200    POE 1200P2   POE 2400   POE 2400P4     Upon open the box of the PoE Injector Hub and carefully  unpack it  The box should contain the following items       The PoE Injector Hub x 1    This Quick Installation Guide x 1      User   s manual CD x 1    Power Cord x 1     Rubber feet x 4     Two rack mounting brackets with attachment screws x 1    If any item is found missing or damaged  please contact  your local reseller for replacement     The POE 1200   POE 1200P2   POE 2400   POE 2400P4  provide remote Web interface for manage  the following  equipments are necessary for further management       a    Network cables  Use standard network  UTP  cables with  RJ45 connectors     Subscriber PC installed with Ethernet NIC  Network Card     The operate system of subscriber PC that running Windows  98 ME  NT4 0  2000 XP  MAC OS9 or later  Linux  UNIX or  other platform compatible with TCP IP protocols     The PLANET POE 1200   POE 1200P2   POE 2400   POE   2400P4 provide a built in browser interface  You can  manage the PoE Injector Hub remotely by having a remote  host with Web browser  such as Microsoft Internet Explorer   Netscape Navigator or Mozilla Firefox     Web Smart PoE Injector Hub    PC   Workstation  with  IE or Netscape Browser        lt a   
3.   dra  J    Mat       _    POE 2400P4       Welcome to PLANET  IEEE 802 3af Power over Ethernet Injector Hub  PLANET Technology Corporation  11F  No  96 Min Chuan Road  Hsin Tien  Taipei  Taiwan  R O C    Tel  886 2 2219 9518  Fax 886 2 2219 9528  Email  Sales planet com tw       Copyright    2008 PLANET Technology Corporation  All rights reserved     Figure 2  Web Main Screen of POE 2400P4    Now  you can use the Web management interface to  continue the PoE Injector Hub management  please refer to  the user manual for more     For security reason  please change and    memorize the new password after this first  setup         J PLANET PLANET Technology Corp  C 4   9    Networking  amp  Communication 2010 000043 004    4  While IP Address be changed or  forgotten admin password        To reset the IP address to the default IP Address     192 168 0 100    and the user name  password to factory  default mode  default user name and password is admin    Press the hardware reset button at the front panel about  10 seconds  After the device is rebooted  you can login  the management Web interface within the same subnet of  192 168 0 xx and default user name   password     Q PLANET    Networking  amp  Communication    POE 2400P4    10    PWR RESET       Hardware Reset button       PLANET    Networking  amp  Communication    802 3af 12 24 Port PoE Injector Hub    POE Series Quick and Easy PoE Environment Deploy       For POE 1200   POE 1200P2   POE 2400   POE 2400P4    Quick Installa
4. tion Guide    5  Customer Support    Thank you for purchase PLANET products  You can browse  our online FAQ resource at the PLANET Web site first to  check if it could solve you issue  If you need more support  information  please contact PLANET switch support team     PLANET online FAQ    http   www  planet com tw en support fag php  type 2    Switch support team mail address    support_switch planet com tw    Copyright    PLANET Technology Corp  2009   Contents subject to revision without prior notice     PLANET is a registered trademark of PLANET Technology  Corp  All other trademarks belong to their respective  owners     
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Répertoire des opérateurs de formation    Baumatic BR508 freezer  HP 431-PowerMeter-1  Contents  取扱説明書 [PDF形式]    Copyright © All rights reserved. 
   Failed to retrieve file