Home
5-inch High Speed Dome User Manual V2.2.0
Contents
1. Limit stops Purpose Limit stops are the user configurable stops which limit the panning and tilting area of the speed dome There are left right up and down limit stops to define an area Steps 1 Move the cursor to LIMIT STOPS and click IRIS to set it ON to enable this feature Click IRIS again to confirm 2 Move the cursor to SETTING LIMIT STOPS and click IRIS You will see the message SET LEFT LIMIT on the screen 3 Click the direction buttons in the PTZ panel to configure the left limit stop Click IRIS to confirm 4 Follow the prompts to configure the right up and down limit stops on the menu Note The new limit stops will overwrite the existed ones by default 5 You can clear the defined limit stops Click IRIS to enter CLEAR STOPS and click IRIS again to clear the stops Elevation angle You can enable the elevation angle of the speed dome You can set ELEVATION SET as ON or OFF 3 4 2 Configuring Presets Purpose A preset is a user defined monitor position point You can simply call the preset number to change the monitor scene to the defined position Steps 1 Move the cursor to enter preset configuration submenu MAIN MENU gt DOME SETTINGS gt PRESETS E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual PRESETS PRESET NUM UNDEFINED lt EDIT LABEL gt PRESET PTZ CLEAR PRESET BACK EXIT Figure 3 12 Preset Configuration Menu 2 Ch
2. HIKVISION 5 inch High Speed Dome User Manual V2 2 0 HIKVISION 5 inch High Speed Dome User Manual Thank you for purchasing our product If there is any question or request please do not hesitate to contact the dealer This manual is applicable to 5 inch High Speed Dome This manual may contain several technically inaccurate places or printing errors and the content is subject to change without notice The updates will be added into the new version of this manual We will readily improve or update the products or procedures described in the manual E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss The precaution measure is divided into Warnings and Cautions Warnings Neglecting any of the warnings may cause serious injury or death Cautions Neglecting any of the cautions may cause injury or equipment damage A A Warnings Cautions Follow these safeguards to prevent Follow these precautions to serious injury or death prevent potential injury or material damage A Warnings 1 In the use of the product you must be strict compliance with the electrical safety regulations of the nation and region Please use the power adapter which is provided by normal company The standard of the power adapter is AC
3. Zoom limit is a user defined limitation of the zoom amount Zoom amount optical zo0mx digital zoom If you set the zoom limit to the minimum value the digital zoom will be invalid and the optical zoom will reach the maximum value if you set the zoom limit smaller the digital zoom will be enabled Steps 1 Move the cursor to ZOOM LIMIT using the direction buttons and click IRIS to enter 2 Click up down direction buttons to choose the limit from 20 40 80 100 and 240 3 Click IRIS button to confirm Note If you set the ZOOM LIMIT as the minimum value 20 the digital zoom function will be disabled and the optical zoom function is at its maximum value Setting the minimum zoom limit If the image is over exposed you can set the zoom limit smaller Enter WIDE LIMIT to set the value Note The selectable values of zoom limit vary depending on the camera models Setting the zoom speed Purpose You can define the speed at which the lens changes from full wide zoom to the optical zoom Steps 1 Move the cursor to ZOOM SPEED using the direction buttons and click IRIS to enter 2 Click up down direction buttons to choose the speed from HIGH default MEDUIM and LOW 3 Click IRIS button to confirm Note You can turn INIT LENS on to trigger a spontaneous lens initiation ensure the normal operation 3 3 2 Configuring the Display Parameters Purpose You can set the image quality of the speed dome including the display paramet
4. it will be triggered when this input channel is shut off 4 Configure the alarm linkage action You can specify the linked action when an alarm occurs On the ALARM ACT submenu you can set the alarm action as preset 1 8 pattern 1 4 patrol 1 8 panning scan tilting scan random scan frame scan panoramic scan day mode night mode or none You can also set the alarm output for the alarm Please refer to Section 3 5 3 Configuring Auxiliary Alarm Output for details 5 Configure alarm priority Enter the PRIORITY menu and set the alarm priority as HIGH MID or LOW If multiple alarms with different priorities are triggered at the same time the speed dome only responds to the alarm with the highest priority if multiple alarms with the same priority are triggered at the same time then the speed dome will respond to each alarm according to the defined alarm sequence 3 5 2 Configuring Alarm Parameters Purpose E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual You can set the alarm related parameters following below instructions including linkage action interval alarm duration and dome activity resumption Steps 1 Enter the alarm parameter configuration menu MAIN MENU gt DOME SETTINGS gt ALARMS gt ALARM SETTING 2 Configure the interval of the alarm sequence When more than one alarm of the same priority occurs at the same time the speed dome will respond to one alarm
5. data does not comply with the requirements of Manchester code E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Chapter 2 Getting Started Before you start You can operate the speed dome using a control device The control devices include the control keyboards DVRs DVSs etc In this and the following chapters operation of the speed dome by the IE browser of a DVR will be taken as an example Note Please make sure that the baudrate date bit and address have been configured to the same as those of the speed dome in the remote configuration interface of the control device Please refer to Table 2 1 for details of the configuration 2 1 Power up Action After the power is applied the speed dome will perform a series of self test actions which include lens actions and pan and tilt movements After the power up self test actions the system information will be displayed for 2 minutes on the live view screen as shown below TYPE DS 2AF1 SN 000000335 ADDRESS 0 COM FORMAT 2400 8 1 PROTOCOL SELF ADAPTIVE VERSION 2 20 BUILD DATE 12 03 31 CHECKING CAMERA Figure 2 1 System Information Table 2 1 Description of System Information Description The model of the speed dome The serial number of the speed dome The default communication address of the speed dome The communication settings of the speed dome Baudrate 4 digits data b
6. of a Character 2 On the SET TITLE menu call the presets standing for each code in sequence to enter the codes E g call preset 10 to get 0 and call preset 2 to get 2 The corresponding numbers characters and position information will be displayed on the screen when you are calling the presets 3 You can call preset 16 to delete the character at the current position Note You can set up to 15 characters for the dome title 6 Exit the title setting menu and display the dome title You can call preset 12 twice within 5 seconds to exit the title setting menu and display the title in the lower right corner or call preset 13 twice within 5 seconds to exit the title setting menu and display the title in the lower left corner or call preset 14 twice within 5 seconds to exit the title setting menu and display the title in the upper left corner or call preset 15 twice within 5 seconds to exit the title setting menu and display the title in the upper right corner Note After exit the SET TITLE menu you can call preset 12 twice within 5 seconds to delete the defined title and remove it from the screen Display the PTZ movements alarm system time etc Purpose You can enable or disable the on screen display of PTZ movements alarms time presets etc and configure the display time Steps 1 Enter the display settings menu MAIN MENU gt DOME SETTINGS gt SYS INFO SETTINGS gt DISPLAY SETTINGS E Hikvision Digital Technology C
7. open field wiring should be buried underground in sealed steel pipe and the steel pipe should be one point grounding Overhead routing method is forbidden In strong thunderstorm area or high induction voltage areas such as high voltage transformer substation high power lightning protection apparatus and lightning conductor are necessary to be appended The design for installation and wiring with lightning protection and grounding in mind should be combined with the lightning protection consideration of the building and conform to the related national standards and industry standards The system should be equipotentially grounded and the grounding equipment must satisfy double request of system anti jamming and electric safety and it must not appear short circuit and open circuit with the zero conductor of strong grid When the system is grounding individual the resistance should be no more than 4Q the section al area of the grounding cable should be no less than 25mm2 For grounding instructions please refer to the Installation Manual of Speed Dome video arrester comgmunicate arrester lightning rod porer p A arrester The speed dome should be in the range of 45 degrees under the lightning rod the resistance of earthing conductor should be smaller than 42 steel jacket Figure A 1 Lightning amp Surge Protection E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch
8. status as ON If the privacy mask is configured the status will be set as ON automatically 5 Delete the privacy mask Enter the CLEAR BLANK menu to delete the current privacy mask 3 3 4 Configuring OSD Settings Purpose You can configure the on screen display of the dome name PTZ control information azimuth viewing angle etc Display the dome title Steps 1 Enter the dome title setting menu MAIN MENU gt SET TITLE 2 Click IRIS to set it to ON and click again to confirm 3 On the live view screen call preset 11 twice within 5 seconds to enter the SET TITLE menu as shown in Figure 3 8 BACK EXIT Figure 3 8 Set Dome Title 4 Click the left right direction buttons to position the cursor to the characters of the title 5 Get the codes for a specific character and enter each code number by calling the preset E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual number i e calling presets 1 9 to enter number 1 9 respectively and calling preset 10 to enter number 0 Note You can get the codes of a specific character using the software we provided For example if you want to display the word HALL as a part of the dome name please follow below steps Steps 1 Enter HALL in the Title filed of the software click OK and you ll see the corresponding codes 0227 0220 0231 0231 listed for it Title a ae 022T 0220 0231 0231 Figure 3 9 Get the Codes
9. surveillance scene is limited Steps 1 Move the cursor to enter the zone configuration submenu MAIN MENU gt DOME SETTINGS gt ZONES E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual ZONES ZONE NUM UNDEFINED EDIT LABEL EDIT ZONE ZONE STATUS SCAN STATUS CLEAR ZONE BACK Figure 3 22 Zone Configuration 2 Choose the zone number Move the cursor to ZONE NUM and click IRIS button to enter Click the up and down buttons to choose the zone number to be configured Note You can configure up to 8 zones 3 Edit the label of the zone Please refer to Step 3 Edit the label of the preset in Section 3 4 2 4 Configure the zone area Steps 1 Move the cursor and click IRIS button to enter EDIT ZONE submenu 2 You can see SET LEFT LIMIT on the screen Click the direction buttons to set the left limit stop 3 Follow the prompts on the screen to set the right limit up limit and down limit 4 Click IRIS button to save the settings and exit 5 Set the zone status and scan status ZONE STATUS enable disable the current status of the zone SCAN STATUS enable disable the scanning in the zone Note ZONE STATUS is not editable After you edited the zone it will switch to ON automatically if you delete the zone the ZONE STATUS will switch to OFF 6 Clear the zone settings Move the cursor to CLEAR ZONE and click IRIS to clear all the settings of the current zone 3
10. you set the value as AUTO it will automatically stop the diagnosis when no errors exist Note If the speed dome uses PELCO P or PELCO D protocol you can set the PELCO CHECKSUM as ON O angle initial position configuration Purpose You can define the initial position of the speed dome on the ZERO ANGLE submenu Steps 1 Move the cursor to ZERO ANGLE using the direction buttons and click IRIS to enter 2 Click the left right up down direction buttons to adjust the monitor angle of the speed dome to find the initial position 3 Click IRIS button to confirm and exit Other system configurations 1 System time configuration Steps 1 Move the cursor to SYS TIME using the direction buttons and click IRIS to enter 2 Click the left right direction buttons to position the cursor on the specific item year month day or hour minute second of which you want to change the value 3 Click the up down direction buttons to increase decrease the value 4 Click IRIS button to confirm and exit Y M D 07 01 18 H M S 15 33 25 DONE OPEN QUIT OPEN Figure 3 4 Set the System Time 2 Fan parameter configuration You can set the FAN CONTROL as TEMP controlled by the temperature ON or OFF 3 EIS Electronic Image Stabilization function configuration E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual You can set the EIS FUNCTION as ON or OFF and set the EIS LEVEL as 0 3 Note
11. 24VA Do not connect several devices to one power adapter as adapter overload may cause over heat or fire hazard Please make sure that the plug is firmly connected on the power socket When the product is installed on wall or ceiling the device shall be firmly fixed If smoke odors or noise rise from the device turn off the power at once and unplug the power cable and then please contact the service center If the product does not work properly please contact your dealer or the nearest service center Never attempt to disassemble the camera yourself We shall not assume any responsibility for problems caused by unauthorized repair or maintenance Boone Do not drop the dome or subject it to physical shock and do not expose it to high electromagnetism radiation Avoid the equipment installation on vibrations surface or places subject to shock ignorance can cause equipment damage Do not place the dome in extremely hot cold the operating temperature shall be 30 C 65 C dusty or damp locations or fire or electrical shock will occur otherwise The dome cover for indoor use shall be kept from rain and moisture Exposing the equipment to direct sun light low ventilation or heat source such as heater or radiator is forbidden ignorance can cause fire danger Do not aim the camera at the sun or extra bright places A blooming or smear may occur otherwise which is not a malfunction however and affecting the endurance of CCD at
12. 4 7 Clearing PTZ Control Settings Purpose You can clear all user defined PTZ control settings including presets patrols patterns zones and time tasks You can also clear privacy masks on this menu Steps 1 Enter the CLEAR SETTINGS menu MAIN MENU gt DOME SETTINGS gt CLEAR SETTINGS E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual CLEAR ALL BLANKS CLEAR ALL ZONES CLEAR SETTINGS CLEAR ALL PRESETS CLEAR ALL PATROLS CLEAR ALL PATTERNS CLEAR ALL TIME TASKS lt DIAGNOSTICS gt EXIT Figure 3 23 Clear Dome Settings 2 Click IRISt on each submenu e g CLEAR ALL PATTERNS Click IRIS again to confirm and exit On DIAGNOSTICS submenu you can also see the self diagnostics information of the speed dome including the occurrence of high temperature the highest temperature the occurrence of low temperature the lowest temperature the occurrences of video loss low voltage dome reboot panning loss tilting loss and communication loss Note Panning loss and tilting loss refer to the failures of panning and tilting for diagnosing the electric motor of the speed dome DIAGNOSTICS HIGH TEMP HIGHEST TEMP LOW TEMP LOWEST TEMP VIDEO LOSS LOW VOLATE POWER UP BACK EXIT DIAGNOSTICS PAN LOST TILT LOST CAMERA LOST BACK EXIT Figure 3 24 Self diagnostics 3 5 Configuring and Handling Alarms 3 5 1 Configuring Alarm Input and Linked Actions Purp
13. AMETER mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual MOTION AUTO FLIP ON PROPORTIONAL PAN OFF PARK TIME 5 MOTION PRESET SPEED LIMIT STOP lt SETTING STOPS gt CLEAR STOPS PARK ACT NONE SCAN SPEED 40 IMAGE FREEZE OFF DOME SPEED MID BACK EXIT ELEVATION SET BACK EXIT Figure 3 11 PTZ Configuration Descriptions of PTZ parameter configuration Auto flip In manual tracking mode when a target object goes directly beneath the speed dome the speed dome automatically rotates flips 180 degrees horizontally to track the object Note AUTO FLIP is set as ON for this speed dome by default and it s not user definable Proportional Panning Purpose When the speed dome is zooming in out you can enable the proportional panning function to automatically reduce or increase the panning and tilting speeds according to the zooming amount This function enables the speed dome to trace the object at a proper speed when the speed dome is Zooming and the monitored scene is narrowed zoom in or enlarged zoom out The panning and tilting speeds will be slower in telephoto state than that of the wide zoom state You can set PROPORTIONAL PAN to ON or OFF to enable disable the function Note This function is enabled automatically while setting the patterns Park time and actions Purpose This feature allows the speed dome to start a predefined park action scan prese
14. Click IRIS again to confirm and exit edit mode of this column Note You can configure up to 8 patrols E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual PATROLS PATROL NUM EDIT PATROL PREVIEW CLEAR PATH BACK EXIT Figure 3 15 Patrol Configuration Menu 3 Edit the patrol Steps 1 Move the cursor to EDIT PATROL and click IRIS to enter edit mode NUM PRESET DWELL SPEED 30 30 30 30 30 30 0 30 DONE OPEN QUIT CLOSE Figure 3 16 Edit the Patrol 2 Click up down direction buttons to position the preset to be edited 3 Click left right direction buttons to position the cursor to PRESET DWELL TIME and SPEED of a preset Click the up and down direction buttons to set each value Note The presets you set for a patrol should be the defined presets dwell time 0 30 seconds selectable is the time that the speed dome pauses on the certain preset speed level 1 40 selectable refer to Table 3 2 is the patrol speed the speed dome switching between the presets 4 Follow above steps to define other presets for the selected patrol You can configure up to 32 presets in sequence for a patrol Press IRIS to save the current settings or press IRIS to cancel and return to the previous menu Table 3 2 Patrol Speed Speed 7 s 2 6 Sl WWI N e E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dom
15. High Speed Dome User Manual Appendix 2 RS485 Bus Connection General Property of RS485 Bus According to RS485 industry bus standard RS485 is a half duplex communication bus which has 1200 characteristic impendence the maximum load ability is 32 payloads including controller device and controlled device RS485 Bus Transmission Distance When using 0 56mm 24AWG twisted pair line according to different baudrate the maximum transmission distance theory table is shown as below Table A 1 Max Distance of RS485 Transmission Baudrate Max Distance 2400BPS 1800m 4800BPS 1200m 9600BPS 800m The transmission distance will be decreased if we use the thinner cable or use this product under the strong electromagnetic interference situation or there are lots of devices are added to the bus on the contrary the transmission distance will be increased Connection Methods RS485 industry bus standard require daisy chain connection method between any devices both sides have to connect a 1200 terminal resistance show as Diagram 1 the simplified connection method is shown as diagram 2 but the distance of D should not be too long _ So Se fo OPS LOS PT N O O Ge st 32H 1 2H 3H AH Figure A 2 RS485 Connection 1 Controller Figure A 3 RS485 Connection 2 Problems in the Practical Application Normally users adopt star shape connection method in construction under this situa
16. T 1 INS LOWCASE a bc de f g hI jj ZOOM DELETE CONTENTS FOCUS CHANGE CONTENTS FOCUS CHANGE MARKER ROCKER CHOOSE CONTENTS OPEN SURE CLOSE BACK Figure 3 14 Edit the Preset Label 2 4 Set the preset position Move the cursor to PRESET PTZ and click IRIS to edit the preset position Use the direction buttons to move the speed dome to find the desired scene position and then press IRIS to confirm the settings and return to the previous menu or press IRIS to cancel Note The preset position settings will be restricted by the limit stops if they are defined 5 Call the defined preset You can select the preset number from the drop down preset list in the control panel of the DVR through a web browser and click the arrow to call a user defined or system defined preset Clear the preset settings Move the cursor to CLEAR PRESET and click IRIS to clear the settings of the current preset 3 4 3 Configuring Patrols Purpose A patrol is a series of dome scanning between the preset positions You can call a patrol to scan the scenes automatically among a group of configured presets in sequence Steps T Move the cursor to enter patrol configuration submenu MAIN MENU gt DOME SETTINGS gt PATROLS Choose the patrol number Steps 1 Move the cursor to PATROLS NUM and click IRIS to enter edit mode 2 Click the up and down direction buttons to select the number of the patrol which is to be configured 3
17. Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Glossary 3D Intelligent Positioning The speed dome can be controlled with the 2 buttons and scroll of mouse can be used under PRIVATE Code protocols with devices and client software Click on a certain area and the device will move to the scene with corresponding point as the center When a rectangular area is selected by left clicking the mouse device will move to its center and enlarge it With right clicking the lens will zoom in and the scroll can easily make the lens zooming and mouse operation automatically incorporates zooming effect Auto Scan The speed dome provides 5 scanning modes pan scanning tilt scanning frame scanning random scanning and panorama scanning The scanning speed can be set by OSD menu from level 1 to 40 with the corresponding speed ranging from 17 second to 40 second Auto Flip In manual tracking mode when a target object goes directly beneath the speed dome the speed dome will automatically rotate 180 degrees in horizontal direction to maintain continuity of tracking Auto Focus The auto focus enables the camera to focus automatically to maintain clear video images Alarm Response Action The speed dome supports 7 alarm inputs which can be set to NO or NC Upon having received the alarm input signal the speed dome will automatically activate a user defined action which can be programmed to preset 1 8 patt
18. The selectable EIS levels vary depending on the camera models 4 Preset direct focus You can set the preset direct focus function ON OF on PRESET DFOCUS submenu 3 3 Configuring Image Parameters 3 3 1 Configuring the Lens Settings Purpose You can set the lens parameters including focus shutter speed iris etc Steps 1 Enter the lens settings menu MAIN MENU gt DOME SETTINGS gt CAMERA PARAMETER CAMERA FOCUS AF ZOOM LIMIT 36 ZOOM SPEED HIGH SLOW SHUTTER ON IRCUT FILTER AUTO D N LEVEL HIGH SHARPNESS 9 BACK EXIT CAMERA WHITE BALANCE AUTO RED BLUE IMAGE FLIP FOCUS LIMIT INIT LENS NOISE REDUCE BACK CAMERA BLC WDR BLC LEVEL AE MODE IRIS SHUTTER GAIN EXPOSURE COMP BACK EXIT CAMERA WIDE LIMIT CHROMA SUPPRESS SATURATION CONTRAST HLC HR MODE BACK EXIT Figure 3 5 Display Settings 2 Configure the focus Settings Setting the focus mode Steps 1 Move the cursor to FOCUS using the direction buttons and click IRIS to enter 2 Click up down direction buttons to choose the focus mode as AF MF or HAF AF Auto focus The lens remains in focus during PTZ movements It is the default focus mode mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual MF Manual Focus Lens focus is operated manually HAF Half auto Focus The lens remains at a fixed focus point when PTZ movements stop when the PTZ movements are resumed the len
19. banes 14 3 4 Configuring PTZ Control Parameters ccs cvseccsccczsdccsivcecees ase decaecvneesssciwi vies sedaes duceaascasecdoscssie nis doieyessns ebaasiasalesseascasseees 16 3 41 Copieu rine PIZ Parameters 6 cseecccsccvscecescueleneceescedscenshensesvecsue cove teeseetaees si4esisons4ontsesilcobnesu ns sonsid cetsosal en taesd cssoextiants 16 3 4 2 Confie Urning PRESEES ss lt 0c05000esase sncsesseceansonsosvsesesnsodsse consis satesviase sndiessndeuadesusedvdesssastescunsesudchvacdeachdensedvancetadcdvacgedcasiass 18 3 4 3 Configuring PAtrOlSwiccccevesececececcaccaceresccevececesuceensccaveceaxaausueeecnueecatcavdeesteavasesdsasesnsdeeesaicevadeavaeteaescanteuval iais 20 SAA Configuring PALLEKINS cveccescevawenavavavenssavencessavanswawavaueusaveaces cay EE E E EEE E 22 3 45 Config rine TIME TASKS ecccicncesesteesececnsacosterancesesvenseevavensestevencesesteesedtancasesuerancedwsvenseetsdeadssansasasdabsdensasosensasuasseaseraete 24 3 4 6 Configuring ZONES cccseccesccssscessccessecessecessecessecsssceseecessecessecsssecsaecessecessecessecesssecessecasecsaecessecesseceaseceasecsaeeesseeages 25 3 4 7 Clearing PTZ ControkSettings cscihcdiedeheccadechcatadeakcavedeskcdvadeckenvedcakievecestdaesdbacstasdvens bi vataesussabaesdasdvensdevabaesdascbcsdanabines 26 3 5 Configuring and Handling Alarms siccsccsscvcccvscceusdecs cues sees es deevskvevssseansvsccdaedevas scans iecsssvsseosicvadsvoievedoohssnadstasntetedbscnssevees 27 3 5 1 Config
20. cgescaseven canes ascessasavseeseedenssgsyeeteceenase esenes oa4esd s4vessea53eyeuseeeo5asdeseseu eusseeeevevens 33 Appendix 1 Lightning amp Surge Protection cccccccssccsssccssscsssecessecsssecssecessecessecesssecessecessecseecessecesseceaseceascessscessecesseceaeeeaees 33 Appendix 2 RS485 Bus Connection c cccccccsccssscsssecsssccssecessecssceceseecsssecsaecessascessecessecessecesseessecessecesseceesecsaeeesecesesesseseaseesaees 34 Appendix 3 24VAC Wire Gauge amp Transmission Distance ccscccssccsssccssscecssscessecesecesscessecesecessecessecsaeeessecesseceseeceaseeaees 36 mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Appendix 4 Table of Wire Gauge Standards ccscscscscsssssssscsscsecsesssssessssesessesescaessesaessesaeseessesaessesaesaesaesaesaesaesaesaesaesags GIOSSANY a sins cccesscccneccccetieceectscccctcssesesccntedcdcedsdeuedsteoveccsevtecsecescecdcssescssscvessdccssveceetsvsesedsivscsdesccceus cossbascascevece sed E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Chapter 1 Overview 1 1 Description Integrated with a built in pan tilt unit and a digital image receiver the speed dome features highly sensitive response and reliable performance and also ensures the image clarity and stability The speed dome can be adopted in various surveillance fields with its full integral functions and feature
21. d resistance f not smoothlye 4 Too many speed domes are connectede 4 Add RS485 distributore f mao Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Appendix 3 24VAC Wire Gauge amp Transmission Distance The following table has described the recommended maximum distance adopted for the certain wire gauge when the 24VAC voltage loss rate is less than 10 For the AC driven device the maximum voltage loss rate allowable is 10 For example for a device with the rating power of 80VA which is installed at a distance of 35 feet 10m away from the transformer then the minimum wire gauge required is 0 8000mm Distance feet m 283 86 451 137 716 218 1811 551 141 42 225 68 358 109 905 275 stata aries Toa han Da toe fe oe 1 eee ta oo Pe fe fee ee Fea eee foam oe fe ne we ew fe om nan woo a fre fe o fore fi oo 170 Pee fo fo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Appendix 4 Table of Wire Gauge Standards Bare Wire Gauge American Wire Gage British Standard Wire Gauge CTOSS sectional Area mm ofBare Wire mri 0 050 43 47 ooo a as ooo3ss 0 090 39 43 0 00636 ono 0950 0 140 35 0 01539 oreo as S sas 0 230 31 0 04115 33 31 30 29 28 24 23 i 0 750 21 0 4417 21 o ee ss e z a as E Hikvision Digital
22. d tilt speeds in proportion to the amount of zoom At telephoto zoom settings the pan and tilt speeds will be slower for a given amount of joystick deflection than at wide zoom settings This keeps the image from moving too fast on the monitor when there is a large amount of zoom Power off Memory This feature allows the speed dome to resume its previous position or status after power is restored By default setting the speed dome supports the power off memory capability with the dwell time of 3 minutes Password protection It s a function to prevent unauthorized changes to the dome settings RS 485 Failure Diagnostics In the presence of failure at the transmitting and receiving terminals of RS 485 communications the speed dome is capable of performing self test and detecting the fault results which will be displayed on the screen Soft Baud Rate The baud rate of the speed dome can be configured by the menu without need of DIP switch settings mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Time Task A time task is a preconfigured action that can be performed automatically at a specific date and time The programmable actions include preset 1 8 pattern 1 4 patrol 1 4 pan scan tilt scan random scan frame scan panorama scan day night mode or none Zone A zone is a pan and tilt area defined by a left right and up down limit stops The speed dome provides ei
23. dit the system information of the software address baudrate system time etc on the system information settings menu Enter the system information settings menu MAIN MENU gt DOME SETTINGS gt SYS INFO SETTINGS mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual SYS INFO SETTINGS SYS INFO SETTINGS SOFT ADDRESS l ZERO ANGLE SOFT ADDR ACTIVE OFF DISPLAY SETTINGS SOFT BAUD 2400 FAN CONTROL TEMP SYS INFO SETTINGS PROTOCOL SET AUTO MATCH 485CHECK SET AUTO BACK EXIT SOFT BAUD ACTIVE OFF EIS FUNCTION ON BROADCAST ADDRESS ON EIS LEVEL 2 PELCO CHECKSUM ON PRESET DFOCUS OFF SYS TIME PROTOCOL STATUS SET OFF BACK EXIT BACK EXIT Figure 3 3 System Information Settings Note You can click the left and right direction buttons in the PTZ control panel via the IE browser of the DVR to enter the next page and return to the previous page of the submenu if more than one page is available Descriptions of system parameter configuration Dome address settings Steps 1 Set the soft address of the speed dome If the SOFT ADDR ACTIVE is set as ON the soft address is the valid address for connecting the speed dome The selectable soft address range is from 1 to 255 If the SOFT ADDR ACTIVE is set as OFF the hard address set by the DIP switch is the valid address of the speed dome the hard address is set as 0 by default Notes Before you set the soft address of the speed dome you
24. e User Manual 4 Preview the patrol Move the cursor to PREVIEW and click IRIS to preview the current patrol and enable the speed dome to scan among the presets 5 Call the defined patrol You can select the corresponding preset number from the drop down preset list in the control panel of the DVR through a web browser and click the arrow to call the related patrol E g call preset 35 to call patrol 1 Please refer to Section 2 2 to find the corresponding preset number for each patrol 6 Delete a patrol You can move the cursor to CLEAR PATH and click IRIS to delete the current patrol 3 4 4 Configuring Patterns Purpose A pattern is a memorized repeatable series of panning tilting zooming and preset movements that can be recalled by a command or automatically performed by a configured function alarm park time task and power up PATTERNS PATTERN NUM EDIT PATTERN PREVIEW CLEAR PATTERN REMAINING BACK EXIT Figure 3 17 Pattern Configuration Menu Steps 1 Move the cursor to enter the PATTERNS submenu MAIN MENU gt DOME SETTINGS gt PATTERNS 2 Choose the pattern number Steps 1 Move the cursor to PATTERN NUM and click IRIS to enter edit mode 2 Click the up and down direction buttons to select the number of the pattern which is to be configured E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual 3 Click IRIS again to confirm Note Yo
25. e of this column Note The configurable privacy mask numbers vary depending on the camera models 3 Configure the position and size of the privacy mask Steps 1 Move the cursor to SET BLANK and click IRIS button to enter edit mode You will see a purple privacy mask on the live window ADJUST BLANK POS FOCUS SHIFT STATUS SAVE OPEN QUIT CLOSE Figure 3 7 Set the Privacy Mask E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual 2 You can see ADJUST BLANK POS message on the screen Click the direction buttons to adjust the position of the privacy mask to the designed scene 3 Click FOCUS IN button and you will see ADJUST BLANK SIZE message on the screen Click the up down buttons to increase decrease the height of the mask and click right left buttons to increase decrease the width of the mask Click IRIS button to save the settings and return to the previous menu and you can see the mask turn to gray 4 To modify the configured mask click IRIS button to enter the SET BLANK menu and click IRIS button again to modify Note The tilt range for configuring the privacy masks is from 0 70 after configured the privacy mask the speed dome can be only tilting in the range of 090 4 Set the privacy mask status Enter the BLANK STATUS submenu and click the up and down direction buttons to set it ON or OFF Note If no privacy mask has been configured you cannot set the
26. e reboot Auto flip Access main menu Pattern 1 Stop programming pattern Pattern 2 Pattern 3 E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Chapter 3 Menu Operation Before you start You can operate the high speed dome using the on screen display menu remotely by connecting to a DVR or a DVS encoder Menu operations via the IE browser of a DVR will be taken as an example in this chapter 3 1 Accessing and Operating the Menu To enter the main menu Connect the speed dome to a DVR and visit the DVR through an IE browser For PELCO P D and other private PTZ protocols call preset 95 from the preset list of the DVR for some other protocols e g Manchester code control protocol call preset 66 to access the menu Please refer to Table 2 3 for details MAIN MENUS lt SYS INFO gt lt DOME SETTINGS gt lt RESTORE DEFAULTS gt lt RESTORE CAMERA gt lt REBOOT DOME gt LANGUAGE ENGLISH SET TITLE EXIT Figure 3 1 Main Menu To move the cursor and operate the menu Move the cursor up down On the IE browser live view page of the DVR click up and down direction buttons or FOCUS IN and FOCUS OUT buttons in the PTZ control panel to move the cursor up and down Enter Exit On the IE browser live view page of the DVR click IRIS to enter a submenu move the cursor to Exit and click IRIS to exit To change the value of a parameter Steps 1 Move
27. ern 1 4 patrol 1 8 pan scan tilt scan random scan frame scan panoramic scan color B amp W mode or none After the alarm is cleared the speed dome is capable of resuming its previous activity or position AUX Output An auxiliary output is a configurable signal from the speed dome back box that can trigger another device to operate The speed dome provides two auxiliary outputs AUX1 andAUX2 The auxiliary output type can be set to NO normally open or NC normally closed by menu And the alarm dwell time is configurable as well Camera Title Title text is the label used to identify the camera viewed on the monitor Up to 15 characters can be used for a title Exposure Compensation Exposure compensation is a function for adjusting the situations including unusual lighting distribution variations non standard processing or other conditions of underexposure or overexposure to get an optimum image Keyboard Control The pan tilt movement and zoom actions of the speed dome can be controlled by the control keyboard DVR matrix etc Label Display The on screen label of the preset title azimuth elevation zoom and other operations can be E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual programmed by menu and displayed on the monitor Limit Stops The speed dome can be programmed to move within the limit stops left right up down which are configurable by the cont
28. ers brightness contrast saturation hue sharpness etc and other advanced functions e g backlight compensation and white balance Steps 1 Enter the display settings menu MAIN MENU gt DOME SETTINGS gt CAMERA PARAMETER 2 Configure the image quality parameters Sharpness The sharpness function can increase the auto gain of the speed dome and sharpen the edges in the picture to enhance the picture details You can set the SHARPNESS level from 0 to 15 The default setting level is 8 mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Hue You can adjust the value of CHROMA SUPRESS between OFF HIGH MID and LOW to suppress the noises in low lighting environment If you set the value higher the hue value will be higher and the noises in the image will increase too Contrast adjust the image contrast on CONTRAST submenu between 0 7 Saturation adjust the image saturation on SATURATION submenu between 0 7 Resolution setting you can set HR MODE as ON to adjust the resolution lower to avoid cross color of the image or switch it OFF to disable the function Note The selectable values of contrast and saturation vary depending on the camera models 3 Configure the advanced functions Day Night Mode There are two parameters available for day night mode configuration 1 IR cut filter It can be set as AUTO DAY or NIGHT AUTO The speed dome is capable of automatically switching
29. eserved 5 inch High Speed Dome User Manual the image Digital Noise Reduction DNR DNR is the process of removing noise from a signal It compensates for the low light conditions and corrects imperfections in the image by removing a large percentage of the noises it helps to deliver a cleaner signal a more visually appealing image and make it easier to identify the objects Self adaptive Protocol The speed dome is compatible with PELCO D PELCO P PRIVATE Code VICON and KALATEL 32 protocol etc and is capable of being self adaptive to these protocols without selecting protocol by DIP switch settings You can also configure the protocol via OSD menu Manchester Code Self test The soeed dome supports Manchester code self test for fault diagnostic while adopting Manchester protocol You can enable the Manchester code diagnosis function by setting the positions 4 5 and 6 of DIP Switch SW2 to ON The corresponding fault code will be displayed on the screen not available during park time Table 1 1 Descriptions of the Fault Code Description Normal control Cable is disconnected Cable is connected and data can be normally received but the address setting is incorrect Cable is connected and data can be normally received but the command setting is incorrect Cable is connected and data can be normally received but the settings of address and command are incorrect Cable is connected but the received
30. estege ete uae ee Tee 3 Chapter 3 Menu Operation iscicsscccceccccceccccetcciscscccdsccccccstessecds ccccontduisstecescssccevececstecssdcscesdssssesteusccteessccesesceseesceeces 5 3 1 Accessing and Operating the M Nu c cccccsccsseccsecsssccssecesseceseecsssecsseeesseescsseceseecesseceeseseascessecessecessessaeeeeesessesenseses 5 3 2 Checking and Configuring System Parameters cccccssscesccsssccsssscessecessecessecsssecseecessecesseceasecsaecessecesseceaseceaeeesseeeees 6 3 2 1 Checking System INFOMATION cccscceccccsesccoscevencccosvecseeesrecosnctanecsesceesecedednesssnasonsaacetoennssadheaaeaibensasaibennacodbeabaranbarso es 6 3 2 2 Configuring System ParaMetelS cccsscccscesssccssccsssccssscessecessecsssecsssccssssecsaecessscessecessscssscessscessecesseceaseeeaesessecenseses 6 3 3 Configuring image Parameter ses sccscecciecsceselosecesktsccsscesecececdeecesccsecesccevhessideoatensstee ARNAN eis 9 3 31 Configuring the Lens Settings siscnnererneieen A aaa aaas 9 3 3 2 Configuring the Display Parameters ccccccssccsssccssecsssecsssecseecssecesseseeecssseecessecesseceaeecssecessecessecesseceaeeesseeeseeenes 11 3 3 3 Configuring Privacy Mask c ccccsccsscsssscessccsssecssscessecessecessecessecssesecessecesscessecessecesseceasecssecessecessecesseceaseesaeeeaeeeges 13 3 3 4 Co nmfigurime OSD SOMES ick ceccscdccssccescccveccesncecxaccasecescdevennceanseucaceeastasseissbaccasndvenstavehceshasdbaccbasthencbavateessassbaecbans
31. first and then respond to the next one after the user defined interval You can set the on ALARM SEQUENCE submenu from 1 to 200 seconds 3 Configure the alarm rest delay If there s a linkage action has already been triggered by an alarm input the speed dome will only respond to the input from the same channel again after the user defined reset delay time This is the rest time that the speed dome considers an alarm to be active when it s physically cleared You can set the ALARM REST DELAY from 0 to 300 seconds 4 Resume the dome activity You can set ALARM RESUME to ON to enable the speed dome to resume its previous activity after the triggered actions finished Notes If the speed dome is moving when a linkage action is triggered it will stop at the current position and resume from this position after the linkage action finishes The speed dome can be configured to resume the PTZ positions focus and iris value 3 5 3 Configuring Auxiliary Alarm Output Purpose An auxiliary output is a configurable alarm output interface on the speed dome back box which can connect and trigger another alarm device to operate Steps 1 Enter the alarm auxiliary output configuration submenu MAIN MENU gt DOME SETTINGS gt AUXS AUX AUXI CLOSE DWELL TIME AUXI DWELL TIME BACK EXIT Figure 3 26 Configure the AUX Output 2 Click IRIS to edit the status of the auxiliary outputs You can set the alarm output type as OPEN normally o
32. from Black and White mode NIGHT and Color mode DAY regarding to the lightening conditions It is the default value NIGHT B W You can switch the IR cut filter into Black and White mode to increase then lens sensitivity in low light conditions DAY Color You can switch it to DAY mode in normal lighting conditions Note You can set the IRCUT FILTER value on this menu and you can call preset 39 to set the IR cut filter mode to DAY mode and call preset40 to set it as NIGHT mode D N level The D N level is the light level for auto D N mode switch As a dividing line IR cut filter switches between DAY and NIGHT when the light condition reaches the user defined D N level Three levels are selectable HIGH MID default and LOW Note D N level configuration varies depending on different mechanism models Some models don t support user defined D N level BLC and WDR functions There are two parameters available for BLC and WDR configuration on this menu 1 BLC WDR You can set the value as ON or OFF to enable or disable the functions 2 BLC LEVEL You can manually adjust the backlight compensation level Note BLC level configuration varies depending on different mechanism models Some models don t support user defined BLC level Exposure compensation function You can set the EXPOSURE COMP value from 0 to 14 The default value is 7 White balance You can set WHITE BALANCE mode as AUTO INDOOR OUTDOOR SELFDEF self defined ATW a
33. ght zones each with configurable label and limit stops If the speed dome has dwelled at a zone without receiving any command over 4 minutes this feature will enable the speed dome to perform panorama scanning within the zone E Hikvision Digital Technology Co Ltd All Rights Reserved First Choice for Security Professionals
34. is deleted pattern 3 and pattern 4 will be deleted as well Clear all the patterns Enter CLEAR PATTERN menu and click IRIS to delete all the defined patterns E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual 3 4 5 Configuring Time Tasks Purpose A time task is a scheduled dome action which can be configured to perform automatically at a specific time Steps 1 Move the cursor to enter the TIME TASK submenu MAIN MENU gt DOME SETTINGS gt TIME TASK 2 Choose the task number Steps 1 Move the cursor to TASK NUM and click IRIS to enter edit mode 2 Click the up and down direction buttons to select the number of the task which is to be configured 3 Click IRIS again to confirm and exit edit mode of this column Note You can configure up to 8 tasks TIME TASK TASK NUM TASK STATE TASK ACTION TASK TIME TASK PREVIEW TASK CLEAR BACK EXIT Figure 3 19 Time Task Configuration Menu 3 Set the task status Steps 1 Move the cursor to TASK STATE and click IRIS to enter edit mode 2 Click the up and down direction buttons to set the task status to ON 3 Click IRIS again to confirm and exit edit mode of this column 4 Configure the task action Steps 1 Move the cursor to TASK ACTION and click the IRIS to enter edit mode 2 Click the up and down direction buttons to select the task action from preset 1 8 pattern 1 4 patrol 1 8 panning scan ti
35. it 1 digit and stop bit 1 digit The version of the firmware The date when the program of the software is compiled 2 2 System defined Presets Purpose mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual The section lists the system defined presets with special functions These presets cannot be edited but only be called through a control device e g a DVR To call the system defined presets remotely you can choose the preset number from the drop down list in the PTZ control panel of the control device through a web browser Please refer to below table for details Table 2 2 Description of System defined Presets Function Set manual limit stops Remote reboot Access main menu Function Auto flip Return to home position Patrol 1 Patrol 2 Patrol 3 Patrol 4 IR cut filter in Stop scanning Start random scanning Start frame scanning Start pan scanning Start tilt scanning Start panorama scanning Patrol 5 Patrol 6 Patrol 7 Patrol 8 IR cut filter out Pattern 1 Pattern 2 Pattern 3 Pattern 4 Enable limit stops Note For Manchester code control protocol the system defined presets with special functions are shown as below Table 2 3 System defined Presets of Manchester Code Control Protocol Function Function Remot
36. lt Dome Settings Default Value 0 2400bps Off Off E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Zero angle Auto Max Optical Zoom High On Auto Off Auto 5 seconds None 28 7 second Off Off On 5 seconds 5 seconds Off NO 5 second Display for 2 seconds 3 6 4 Restoring Default Camera Settings Enter default camera settings menu MAIN MENU gt RESTORE CAMERA Click IRIS to restore the camera settings to the default value or click IRIS to exit Note Camera settings include the lens settings and display settings 3 6 5 Rebooting the Dome Enter MAIN MENU gt REBOOT DOME and click IRIS to reboot the speed dome remotely E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Appendix Appendix 1 Lightning amp Surge Protection This product adopts TVS plate lightning protection technology to avoid damage caused by pulse signal that is below 3000W like instantaneous lighting surging etc According to the actual situation outdoors necessary protection measures must be taken to secure the electrical safety The distance between signal transmission line and High voltage equipment or high voltage cable is at least 50m Outdoor wiring should better be along the eaves as much as possible In the
37. lting scan random scan frame scan panoramic scan day mode night mode and none 3 Click IRIS again to confirm and exit edit mode of this column 5 Set the task time Steps 1 Move the cursor to TASK TIME and click IRIS to enter edit mode 2 Click the left and right direction buttons to position the cursor to WEEK START H M and END H M 3 Click the up and down direction buttons to select the specific day and time E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual 4 Click IRIS to confirm and exit Note The weekday can be set to be from Monday to Sunday or Whole Week WEEK WHOLE WEEK START H M 00 00 END H M 00 00 DONE OPEN QUIT CLOSE Figure 3 20 Set the Task Time 6 Preview the time task Move the cursor to TASK PREVIEW and click IRIS to view the time action and status of the scheduled task z TIME ACTION STATE NONE OFF NONE OFF NONE OFF NONE OFF NONE OFF NONE OFF NONE OFF NONE OFF CADNARWNHHEG 00 00 00 00 00 00 00 00 oooocooco o oooocoocoo Figure 3 21 Preview the Task Time 7 Delete the time task Move the cursor to CLEAN TASK and click IRIS to delete the time and action of the current task 3 4 6 Configuring Zones Purpose A zone is a panning and tilting area defined by the left right and up down limit stops You can configure the zones on ZONES submenu You can define a zone when the targeted
38. need to confirm it s within the control range of the control device e g the DVR After you enable disable the soft address the speed dome will reboot automatically to activate the settings 2 Set the broadcast address of the speed dome When the BROADCAST ADDRESS is set to ON the control device with address O is capable of controlling all domes connected to it Soft baudrate settings If the SOFT BAUD ACTIVE is set as ON the soft baudrate is the valid baudrate for the speed dome with 2400 4800 9600 and 19200 selectable If the SOFT BAUD ACTIVE is set as OFF the baudrate should be set by the DIP switch Note After you enable disable the soft baudrate the speed dome will reboot automatically to activate the settings Protocol and RS 485 settings Purpose This speed dome allows you to configure the protocol via OSD menu Steps mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Select the protocol Choose the protocol on PROTOCOL SET submenu You can configure it as AUTO MATCH PELCO P PELCO D HIKVISION KALATEL or VICON When you choose AUTO MATCH it is protocol self adaptive Set the protocol status Set the PROTOCOL STATUS SET as ON to enable the user defined protocol Enable the RS 485 configuration diagnosis You can set 485CHECK SET as ON or AUTO for automatic RS 485 configuration diagnosis If the configuration is incorrect an alert will be received if
39. o Ltd All Rights Reserved 5 inch High Speed Dome User Manual DISPLAY SETTINGS ZOOM SHOW 2 PT SHOW 2 ALARM SHOW DISPLAY SETTINGS ADDRESS SHOW OFF ERROR RATE SHOW OFF TIME SHOW PRESET SHOW ZONE SHOW AAG rh BACK EXIT BACK EXIT Figure 3 10 Display Settings 2 Move the cursor to DISPLAY SETTINGS using the direction buttons and click IRIS to enter 3 Move the cursor to the target item and click IRIS and click up down direction buttons to choose each display mode as ON or OFF and define each display time as 2 seconds 5 seconds or 10 seconds 4 Click IRIS button to confirm Note If you enabled the OSD for both ZOOM and PT while calling a preset the preset label will be displayed on the screen until the preset finishes Display the viewing Direction The speed dome shows the viewing direction when you are manually controlling it to rotate Table 3 1 Viewing Direction Display Display N NE E SE S SW W NW Indication North Northeast East Southeast South Southwest West Northwest Note The north direction refers to the 0 angle initial position 3 4 Configuring PTZ Control Parameters Purpose You can configure pan tilt and zoom movements and configure PTZ control functions including presets patrols patrols etc for the high speed dome 3 4 1 Configuring PTZ Parameters Enter PTZ configuration menu MAIN MENU gt DOME SETTINGS gt MOTION PAR
40. oose the preset number Move the cursor to PRESET NUM and click IRIS to enter Click the up and down buttons to choose the preset number which needs to be edited If the preset has been defined the preset label will be listed under the number if it has not been defined you will see UNDEFINED under the number Notes There are up to 254 presets can be set for the speed dome The system defined presets will be displayed on this submenu and they are not editable 3 Edit the label of the preset PRESET 1 ZOOM DELETE CONTENTS FOCUS CHANGE CONTENTS FOCUS CHANGE MARKER ROCKER CHOOSE CONTENTS OPEN SURE CLOSE BACK Figure 3 13 Edit the Preset Label 1 Steps 1 Move the cursor to EDIT LABLE and click IRIS to enter the edit mode 2 Click FOCUS IN in the PTZ control panel to switch between the character lists including capital alphabet lowercase alphabet symbols and numbers click the up down and left right direction buttons to move the cursor to choose a specific character to input 3 Click FOCUS OUT to position the cursor on the label where the character needs to be modified Click ZOOM IN to delete it 4 Click IRIS to inset the selected character from the letter number symbol list to the label 5 Click FOCUS IN to exit the character lists and click IRIS again to confirm and exit the submenu E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual LABEL PRESE
41. ose This section explains how to configure the speed dome to respond to alarm events with alarm linked actions such as calling presets patrols patterns scanning etc Steps 1 Move the cursor to enter the alarm configuration submenu MAIN MENU gt DOME SETTINGS gt ALARMS gt ALARM SETTING E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual ALARM ALARM SETTING ALARM RESUME J ALARM NUM 1 ALARM SEQUENCE 5 PRIORITY HIGH ALARM REST DELAY 5 ALARM ACT NONE ALARM SETTING AUX NONE ALARM INPUT OPEN BACK Ee BACK EXIT Figure 3 25 Alarm Configuration Menu 2 Choose the alarm number Steps 1 Move the cursor to ALARM NUM and click the IRIS to enter edit mode 2 Click the up and down direction buttons to select the number of the alarm which is to be configured 3 Click IRIS again to confirm and exit edit mode of this column Note You can configure up to 7 alarms 3 Configure the alarm input Steps 1 Move the cursor to ALARM INPUT and click the IRIS to enter edit mode 2 Click the up and down direction buttons to set the input status You can configure it as OPEN Normally open CLOSE Normally closed or OFF disable the alarm input 3 Click IRIS again to confirm Note If you set the status as OPEN alarm will be triggered by high electricity level if you set the status as CLOSE alarm will be triggered by low electricity level if you set the status as OFF
42. pen and CLOSE normally closed mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Note There are 2 auxiliary outputs configurable 3 Move the cursor to DWELL TIME to set the duration of the auxiliary output signal The configurable rage is 0 60 seconds 4 Link the auxiliary output to the configured alarm Steps 1 Enter MAIN MENU gt DOME SETTINGS gt ALARMS gt ALARM SETTING and choose the alarm number that you want to link the auxiliary output to 2 Move the cursor to AUX and click IRIS to configure the auxiliary output to the alarm You can choose NONE to disable auxiliary alarm outputs choose 1 to active AUX 1 or choose 2 to active AUX 2 3 6 Others 3 6 1 Configuring Dome Authentication Purpose You can change and enable disable the password to set the dome authentication to prevent unauthorized changes to the dome settings After you set and enable the password you need to input the password every time you call preset 95 to enter the menu Steps 1 Move the cursor to enter password modification submenu MAIN MENU gt DOME SETTINGS gt PASSWORD gt EDIT PASSWORD 2 Click IRIS to enter edit mode 3 Click the left right buttons to move the cursor on the current password and click up down or FOCUS IN OUT buttons to choose the number 4 Click the right direction button to move the cursor to INPUT PW AGAIN and input the password again 5 Click IRIS to save
43. ris value gain value and shutter speed according to related content in this section if you choose MANUAL mode Setting the iris value Purpose The IRIS value measures the amount of light entering to the lens You can set the iris value from 0 to 13 in response to the changing light conditions Note Iris is fully closed at value 0 and fully open at value 13 Setting the gain The value of gain indicates the amplification degree of the original image signal You can set the value from Oto 15 Setting the shutter speed Purpose The speed of the electronic shutter controls the amount of light entering to the lens in a unit of time a second You can manually configure the shutter speed for the speed dome and you can also enable the slow shutter function for low lighting circumstances 1 Shutter speed If you set the SHUTTER value bigger shutter speed is faster the amount of entering light per second is fewer and the image is darker You can set it as 1 2 4 8 15 30 50 125 180 250 500 1000 2000 4000 or 10000 Note The value of X indicates that the shutter speed is 1 X second mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual 2 Slow shutter Set SLOW SHUTTER as ON default the shutter speed can automatically slow down to extend exposure time under low lighting circumstances to obtain clearer image 4 Configure the zooming parameters Setting the zoom limit Purpose
44. rol keyboard DVR or client application software Preset Freeze Frame This feature freezes the scene on the monitor when going to a preset This allows for smooth transition from one preset scene to another and also guarantees that masked area will not be revealed when going to a preset Presets Each of the user definable presets can be programmed to use pan tilt camera settings and other settings When preset is called the speed dome will automatically move to the defined position User is allowed to add modify delete and call each preset Patrol The high speed dome provides up to 8 patrols In each patrol user is allowed to specify the scanning track by a group of user defined presets with the scanning speed between two presets and the dwell time at the preset separately programmable Pattern A pattern is a memorized repeating series of pan tilt zoom and preset functions that can be recalled with a command from a controller or automatically by a configured function alarm park time task or power up By default the focus and iris are in auto status during the preset is being memorized Privacy Mask The privacy mask allows a user to program user defined areas that cannot be viewed by the operator of the dome system A masked area will move with pan and tilt functions and automatically adjust in size as the lens zooms telephoto and wide Proportional Pan Proportional pan automatically reduces or increases the pan an
45. s such as forest railway airport harbor oil field plaza park scenic spot street train station stadium etc sy Figure 1 1 Appearance 1 2 Functions Wide Dynamic Range WDR The wide dynamic range function helps the speed dome provide clear images even under back light circumstances When there are both very bright and very dark areas simultaneously in the field of view WDR balances the brightness level of the whole image and provide clear images with details Privacy Mask This function allows you to block or mask certain areas of a scene to prevent the personal privacy from being recorded or viewed Backlight Compensation BLC If the speed dome focuses on an object against strong backlight the object will be too dark to be seen clearly The BLC function can compensate light to the object in the front to make it clear but this causes the over exposure of the background where the light is strong DAY NIGHT Auto switch The speed dome delivers color images during the day as light diminishes at night it switches to night mode and delivers black and white images with high quality You can also switch it to NIGHT mode manually to increase the sensitivity in low light conditions White Balance White balance is the white rendition function of the speed dome to adjust the color temperature according to the environment automatically It can remove the unrealistic color casts in E Hikvision Digital Technology Co Ltd All Rights R
46. s will focus automatically 3 Click IRIS button to confirm Setting the focus limit Purpose Focus limit is the focal length limit of the speed dome You should configure the focus limit longer when the target is at a distance to avoid the speed dome focusing on the objects close to it or configure the focus limit shorter when the target is near the speed dome and avoid it focusing on the objects father You can set FOCUS LIMIT as 1CM default 30CM 1M or 3M to make sure that the speed dome focuses on the target when you set it as AUTO the focus limit will automatically change according to the lens zooming 3 Configure the Iris gain and shutter speed Setting the AE mode Purpose AE mode defines the priority of iris shutter and gain while the speed dome adjusting the brightness of the live view You can change the mode on AE MODE submenu AUTO Auto iris auto shutter and auto gain The speed dome adjusts the values automatically responding to the lighting conditions It is the default mode IRIS User defined iris value auto shutter and auto gain It is the iris priority mode Please define the iris value according to related content in this section if you choose IRIS mode SHUTTER User defined shutter speed auto iris and auto gain It is the shutter priority mode Please define the shutter speed according to related content in this section if you choose SHUTTER mode MANUAL User defined iris gain and shutter Please define the i
47. t pattern etc automatically after a period of inactivity park time You can set PARK TIME from 5 to 720 seconds and set the park action PARK ACT as preset 1 8 pattern 1 4 patrol 1 8 pan scan tilt scan random scan frame scan panoramic scan day mode night mode or none Note If no control signal is received after the park time under the following circumstances no park actions will be performed in the process of performing dome actions by calling special presets or in the process of performing external alarm linked actions Image freeze This feature enables the live view to switch directly from one scene defined by a preset to another without showing the middle areas between these two to ensure the surveillance efficiency It can also reduce the use of bandwidth in a digital network system You can set IMAGE FREEZE on to enable this function mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual PTZ speed Purpose You can define the speed of the dome movements 1 DOME SPEED the manual movement speed can be set as HIGH MID or LOW 2 SCAN SPEED scan speed defines the scan degree per second of panning scan tilting scan frame scan random scan and panoramic scan Scan speed is adjustable from 1 to 40 degrees per second 3 PRESET SPEED the speed of calling a preset can be set from level 1 to 8 The higher level corresponds to the faster speed to call a preset
48. the same time mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual 6 Please use the provided glove when open up the dome cover avoid direct contact with the dome cover because the acidic sweat of the fingers may erode the surface coating of the dome cover 7 Please use a soft and dry cloth when clean inside and outside surfaces of the dome cover do not use alkaline detergents E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual Table of Contents Table of COnteNtS e onsets casvescsedses senses secdcesssseaeecnes say nsdsessdeesdnkeedcedees seven deus tna donved ded coeseeveueeesessay ceded sdeeasssescecessss 1 Chapter 1 Oar Tari An A E E 1 1 1 Breni oae E E OEN EN O sien causceabensacsea esaeas 1 1 2 FUNCTIONS 5 ss ccsssaicssessbesstesssesosoiesobetedesstasoiasssaissabesobasatasoinssiaiesoneiobadutadbicasedsdedosedssedubedecessceissossdebedsbedeinsodatedebedeseddbebviese 1 Chapter 2 Getting Stamnes oss ccc sicessvccwestecsevvecee sehen cedeicensss coatbeceehenlecdusivedies spans ecduasccavivwcoheccuyeceeesss EEEE 3 2 1 Power Wp ACE OMS esccvcasacssvascacesnsesuseasicavasasacusviscedtese casudsstc sass cednavissn asniasudesce sue needs gcdcacddecdecdeacddedstsaddesdeceedvacdsastecdaeasaies 3 2 2 System detiitied Presets ccs cescccvecesecssecasdececcsccsvsduacdsccesecsesvsccsdee sack seca saescdessesasgeabesasdseeseesintetiease gsc eteint
49. the changes and exit 6 Enter the START USING submenu and switch the status to ON and click IRIS to save PASSWORD START USING INPUT PW 123456 EDIT PASSWORD INPUT PW AG 1 2345 6 DONE OPEN BACK EXIT QUIT CLOSE Figure 3 27 Set the Password E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual 3 6 2 Configuring Line Synchronization Purpose This speed dome supports user defined line external synchronization of the signal Steps 1 Enter PTZ configuration menu MAIN MENU gt DOME SETTINGS gt LINE SINC 2 Set the synchronization mode ON Enable the line synchronization Adjust the phase of the line synchronization to synchronize input power with the line synchronization phase V phase configurable from 0 to 255 degrees OFF Set the line synchronization off Note External synchronization is not supported LINE SYNC LINE LOCK ON V PHASE 0 BACK EXIT Figure 3 28 Synchronization Configuration 3 6 3 Restoring Default Dome Settings Purpose You can reset all dome settings to factory default parameters as shown in the table below Note Dome settings are mainly of PTZ parameters and alarm parameters and also include some system settings e g dome address Enter default dome settings menu MAIN MENU gt RESTORE DEFAUTLS Click IRIS to restore the dome settings to the default value as shown in below table or click IRIS to exit Table 3 3 Defau
50. the cursor to the target item and click IRIS button and you can see the cursor diamond mark will change to be hollow 2 Click the up down or left right buttons in the PTZ control panel to choose the value from the selectable list 3 Press IRIS to confirm the change or click IRIS to cancel and restore the original value The diamond mark will change back to be stuffed mo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual To set the language of the menu Enter MAIN MENU gt LANGUAGE you can set the language of the on screen menu in Chinese or in English 3 2 Checking and Configuring System Parameters 3 2 1 Checking System Information Purpose System information menu displays the current system information of the speed dome Figure 3 2 including model address protocol etc The information shown on this submenu is similar to the system information shown after the power up action Please refer to Section 2 1 for more details Enter the system information display menu MAIN MENU gt SYS INFO SYS INFO TYPE DS 2AF1 ADDRESS 0 COM FORMAT 2400 8 1 PROTOCOL AUTO MATCH TEMPERATURE 44 C VERSION 2 20 BUILD DATE 12 03 31 BACK EXIT Figure 3 2 System Information Notes Information on this menu cannot be edited The temperature refers to the internal temperature of the high speed dome 3 2 2 Configuring System Parameters Purpose You can check and also e
51. tion the terminal resistors must be connected between two farthest devices as Figure 4 1 and 15 but this connection method is not satisfy the requirement of the RS485 industry standard so that it will lead to some problems such as signal reflection anti jamming ability decline when the devices are E Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual faraway At this time the speed dome will be uncontrollable or self running etc 1 Ox Controller device 15 Figure A 4 Star Shape Connection For such case the best way is adding a RS485 distributor This product can effectively change the star shape connection to which satisfies the requirement of RS485 industry standard in order to avoid those problems and improve the communication reliability RS485 Distributor Figure A 5 RS485 Distributor FAQ of RS485 Bus a a O O O O OO O Phenomenone Probable Cause Solutionse ia Pelee paren e ea dome do the between Host and the Speed Dome Dome to make a match self check but 2 RS485 are connected incorrectly 2 Change the RS485 and RS485 wirese cannot be 3 Wiringdropse 3 fasteningthewiree controlled 4 RS485wirebroke e 4 ChangeRS485wiree The speed 1 loose contact ofRS485e 1 fastening RS485 wires e dome can be 2 one RS485 wire broke 2 ChangeRS485 wiee controlled but 3 Host and speed dome are too far awaye 3 Add terminal matche
52. u can configure up to 4 patterns Edit the pattern Step 1 Move the cursor to EDIT PATTERN and click IRIS to enter edit mode REMAIN MEMORY 100 DONE OPEN QUIT CLOSE Figure 3 18 Edit the Pattern 2 Click the PTZ control buttons and direction buttons to pan tilt or zoom in out the speed dome to draw a movement path The speed dome can automatically memorize the path you operated as a pattern 3 Click IRIS again to save the pattern and exit edit mode Notes REMAIN MEMORY indicates the remaining memory of the speed dome for configuring the patterns When it reaches 0 no more patterns can be configured You can also see the remaining memory shown under PATTERNS menu as REMAINING The panning tilting movements and the lens operations cannot be memorized simultaneously Preview the pattern Enter the PREVIEW menu to preview the current pattern Call the defined pattern You can select the corresponding preset number from the drop down preset list in the control panel of the DVR through a web browser and click the arrow to call the related pattern E g call preset 41 to call pattern 1 Please refer to Section 2 2 to find the corresponding preset number for each pattern Delete the patterns Delete a chosen pattern Click IRIS to enter EIDT PATTERN and you can see DEL PATH ABOVE Click IRIS to delete the pattern Note If you delete the current pattern the following pattern will also be deleted E g if pattern 2
53. uring Alarm Input and Linked Actions cccccccccssecssscesessecsseecssecessecesecessecsaeecsseeeeecessecesseceasecsaeeessesenes 27 3 5 2 Configuring Alarm Parameters ccccccscccssccsssecssecessecessscessecsssecssecessecessaecessscessecesseceasecssecessecessecesseceaseseaeeeaeeages 28 3 5 3 Configuring Auxiliary Alarm Output snnsenesnesenenensennrnnsrnnsnarnnsenrrnnsrnrrnasrnnssraoressraseeaernssenerassraseensrnseenernesrneeeant 29 3 6 OUN ONS ees cacicscreecies cece aceccceclaceccacrcanektinereewsvevewdeeieseewcosveceesvevteceeaescvewtoverscesdsiuiaed ueyisayleusd siycashus ante daahaauadaanagaeeaupaatsaaabeses 30 3 6 1 Configuring Dome Authentication cccccccccccssccssecsssecsssecsseecsseeessecssecesssecessecessecsssecssecessecessecesseceaeessaeeeseeeenes 30 3 6 2 Configuring Line Synchronization ccceesccessccssscessecessecesecsssccssecessecessecseesecessecesseceasccssecessecessecesseceaseesaeceaeeeees 31 3 6 3 Restoring Defauilt DOME SettihgS viicccicscccsecececcecccessecesccevsatcsanseuceccastcesccevecedccvdsesaecsdenssesedsabeessasesnctdeesdesedsobaessasarinss 31 3 6 4 Restoring Default Camera SettingS cccccsccsssccssecessecsssecsseesseeesseceeecssesesessecessecsaessesecessecessecesseseaeeesaesesseeges 32 3 6 5 Rebooting THE DOME uc ssceccsesssacesssecesstosnsoavsesesnsedesesoss osntesviess snssdssedessioanseaviesusasoduanasedededsaddeded concedvbagesuacdsvaadeacdsaaes 32 APRON E E eax secccesens
54. uto tracking HAUTO half auto OUT AUTO auto mode for outdoors and NA AUTO auto mode for sodium lamp light Note In SELFDEF mode you need to define the value of RED and BLUE Digital noise reduction You can set the NOISE REDUCE function OFF HIGH MID or LOW HLC high light compensation You can set the HLC function level as 0 3 Image flip If you turn the IMAGE FLIP function on the image will be flipped diagonally along its central axis shown as the mirror reflection of the image 2 mmo Hikvision Digital Technology Co Ltd All Rights Reserved 5 inch High Speed Dome User Manual 3 3 3 Configuring Privacy Mask Purpose Privacy mask enables you to cover certain areas on the live video to prevent certain spots in the surveillance area from being live viewed and recorded The masked areas can move with the pan tilt movements and automatically adjust the size as the lens zooming in out Steps 1 Move the cursor to enter the privacy mask configuration submenu MAIN MENU gt DOME SETTINGS gt PRIVACYS PRIVACY BLANKS BLANK NUM 1 BLANK STATUS OFF SET BLANK CLEAR BLANK BACK EXIT Figure 3 6 Privacy Mask Configuration Menu 2 Choose the privacy mask number Steps 1 Move the cursor to BLANK NUM and click IRIS button to enter edit mode 2 Click the up and down direction buttons to select the number of the pattern which is to be configured 3 Click IRIS again to confirm and exit edit mod