Home

Impression 300XL RZ RGB Manual V1.2 EN

image

Contents

1. 17 5 1 Safety reg lations gini dp ete pd edited lve oad eed ti ea 17 5 2 Maintenance Intervals rule of thumb sssesssseeeneeeneneneene nennen nnne 17 Technical Specifications enin eer tea eterne re ertt asa eee tacita tert 18 j d EP Re PS ee M asiana 19 GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 3 1 Description of Device 1 Moving head actively and passively cooled 2 Arm with various cooling vents 3 Tilt lock to secure and lock the tilt movement see also 1 1 4 LCD Display Menu data entry 5 Base with various connectors and Camlock mounting system gt Safety eyelets DMX Output 5 Pin DMX Output 3 Pin Micro fuse 6 3x32mm T15A 9 Power On Off 10 6 7 8 9 10 10 2x Safety eyelets 11 Powercon Mains supply base side 2 12 Blank panel 13 DMX Input 3 Pin 14 DMX Input 5 in pa wb om 11 12 13 14 Note Only connect one cable to the DMX Out Input at a time GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 4 bhP 300 XL RZ RGR 1 1 Safety Instructions The IMPRESSION 300 XL RZ RGB is an advanced technology product To guarantee smooth operation it is necessary to follow the following instructions The manufacturer of this device will not take responsibility of damages through any disregard of the information in this u
2. German Light Products GmbH Mounting in hanging Position 7 Mounting in sidewise Position 8 Mounting on the Floor sses 7 N Normal Mode ssesss 12 O Optical parts sssssseeess 18 P Pan Movement ssssssseeenes 18 Power Supply sss 9 Powercon Mains supply 4 S Safety distance sssssssssssss 6 Safety Instructions sssssssssss 5 Secure the Device 9 Software Version sssssssssssss 1 T Technical Specifications 18 The Menu Field esesssssssss 9 Tilt Movement ssssseen 18 U Up Down keys eene 9 V MBG 70 E E SN RNS Sh 6 wW Warranty claims aseeseensa 6 Weights and Measures 18 White Mode seeeesses 14 Manual Version 1 2 from Software Version 1 01 03 02 EC ssion P d 19 e soo ML RPZREE Gto GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 20
3. from Software Version 1 01 03 02 Manual Version 1 2 GERMAN LIGHT PRODUCTS since 1994 e mail service glp de Internet http www glp de e 300 XL RZ REE For your notes GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 2 p soo VL EZREE Gto Table of content Description of Device eere re Eee eink e e ERR R Rn opa rue ee 4 44 Safety Instructions cai ea a see ee p ve ee eae eet 5 Preparation and Installation eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee nennen ennt nnns 6 24 MOUNTING ished edente tatit eo pe echo ee te heathen bth a i Ere vei e RC 6 2 1 1 Mounting on the floor upright sense gar nno ARRAROEN ERR 7 2 1 2 Mounting in hanging position Head down seen 7 2 1 3 Mounting in sideway pOSition esses seen nnne nnne nnne en 8 2 2 Securing the Device cic raped ies eed ee t ae epa e eeepc duco 9 2 9 Gonnectl ns su oce htec eee tede tuat ed esae ecd cast ea DER eae RAE arana aan px eta S dao EE en desisaeeeals 9 2 3 1 Power Supply ie IR RED E REP Lee deen ee e LL hi a 9 2 8 2 D p ssa a RU DNE ERU ON ena a Se AEN tn ln 8 aed 9 The Menu Field eased tied tet escudo oin adeste sms Eniadu Eis 9 DMX Channel SHlieel ie tibia ib relates estos abhi aaa eE iaaa et 12 Maintaining and Cleaning the IMPRESSION 300 XL RZ RGB
4. 0 660 coarse 2 PAN fine High Pos High Pos 2 6 16 Bit 3 Tilt 0 300 coarse 4 Tilt fine High Pos High Pos 1 2 Time and Value DMX HEX 96 0 255 00 FF 0 100 0 255 00 FF 0 100 0 255 00 FF 0 100 0 255 00 FF 0 100 5 Color Colors adjustable via RGB 0 7 00 07 0 2 5 fixed Color 01 Red 8 15 08 0F 3 5 5 Color 02 Amber 16 23 10 17 6 8 5 Color 03 Warm Yellow 24 31 18 1F 9 12 5 Color 04 Yellow 32 39 20 27 13 15 5 Color 05 Green 40 47 28 2F 16 18 5 Color 06 Turquoise 48 55 30 37 19 21 5 Color 07 Cyan 56 63 38 3F 22 24 5 Color 08 Blue 64 71 40 47 25 27 5 Color 09 Lavender 72 79 48 4F 28 30 5 Color 10 Mauve 80 87 50 57 31 34 5 Color 11 Magenta 88 95 58 5F 35 37 5 Color 12 Pink 96 103 60 67 38 40 5 White CTO Color temperature 3200K 104 111 68 6F 41 43 5 GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 1 2 pb 3200 XL RZ RGE Channel Function Time and Value DMX HEX 96 White Color temperature 112 119 70 77 44 46 5 5600K White CTB Color temperature
5. 120 127 78 7F 47 49 5 7200K Rainbow Effect Stop 128 80 50 Rainbow Effect slow fast 129 223 81 DF 51 88 Rainbow Effect random colors slow fast 224 255 E FF 89 100 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 Shutter Shutter closed 0 15 00 0F 0 5 5 Random Pulse effect slow fast 16 47 10 2F 6 18 5 Up dimming then Shutter closing slow fast 48 79 30 4F 19 31 random patterns Shutter open then down dimming slow fast 80 111 50 6F 32 43 random patterns Up dimming then down dimming slow fast 112 143 70 8F 44 56 random patterns Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1Hz 10Hz 200 239 C8 EF 78 94 Shutter open 240 255 FO FF 95 100 10 Dimmer Dimmer 096 10096 0 255 O FF 0 100 11 Color No color temperature correction 0 0 0 temperature Continuous color temperature Applicable only for 7 255 07 FF 3 100 correction between 3200k 7200k White color 12 Special Max Power Mode Max light output without 0 15 0 0F 0 5 5 white balance White Mode White balance used 16 31 10 1F 6 12 5 Fan min as long as temp lt 900 224 229 E0 E5 88 89 5 RESET Normal Mode 250 255 FA FF 98 100 13 Move No movement 0 00 0 ment Movement Size Phase PAN 1 0
6. Shutter Shutter closed 0 15 00 0F 0 5 5 Random Pulse effect slow fast 16 47 10 2F 6 18 5 Up dimming then Shutter closing slow fast 48 79 30 4F 19 31 5 random patterns Shutter open then down dimming slow fast 80 111 50 6F 32 43 random patterns Up dimming then down dimming slow fast 112 143 70 8F 44 56 random patterns Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1Hz 10Hz 200 239 C8 EF 78 94 Shutter open 240 249 FO F9 95 97 5 RESET Min 3 Sec 250 FA 98 Shutter open 251 255 FB FF 99 100 10 Dimmer Dimmer 0 100 0 255 0 FF 0 100 11 Zoom Steplessly adjustable Zoom 10 26 0 255 0 FF 0 100 High Resolution Extended Mode 13 DMX Channels Channel Function Time and Value DMX HEX 1 PAN 0 660 0 255 00 FF 0 100 coarse 2 PAN fine High Pos High Pos 2 6 16 Bit 0 255 00 FF 0 100 3 Tilt coarse 4 Tilt fine 5 Red Color mixing system Red 0 10096 0 255 00 FF 0 100 coarse 6 Red fine Color mixing system Red Low 0 255 00 FF 0 100 7 Green Color mixing system Green 0 10096 0 255 00 FF 0 100 coarse 8 Green Color mixing system Green Low 0 255 00 FF 0 100 fine 9 Blue Color mixing system Blue 0 10096 0 255 00 FF 0 100 coarse 10 Blue fine Color mixing system Blue Low 0 255 00 FF 0 100 11 Shutter Shutter closed 0 15 00 0F 0 5
7. Y Pay attention to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 The installation shall be done by qualified personal only For the various mounting positions of the IMPRESSION 300 XL RZ RGB standing on the floor sideways or hanging different accessories kits are available Using any required kits along with the standard mounting connectors on the base of the fixture will ensure a safe and firm installation GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 2 1 1 Mounting on the floor upright To operate the IMPRESSION 300 XL RZ RGB in an upright position please use the dedicated floor stand which ships with all original fixtures The floor stand is mounted to the base of the fixture using the two Camlock quarter turn fasteners Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90 to lock them Do the opposite to release them again On both sides you ll find eyelets to pull though a fixing strap This allows additional bracing of the floor stand during the upright operation e e e o e e Hl ofo Q M10 C Thread amlock oo 3 5 m eo eb o TO e e e 2x Camlock 2x Flat Eye 2 1 2 Mounting in hanging position Head down To operate the IMPRESSION 300 XL RZ RGB in a hanging position two omega brackets c
8. fine High Pos High Pos 1 2 16 Bit 0 255 00 FF 0 100 5 Color Colors adjustable via RGB 0 7 00 07 0 2 5 fixed Color 01 Red 8 15 08 0F 3 5 5 Color 02 Amber 16 23 10 17 6 8 5 Color 03 Warm Yellow 24 31 18 1F 9 12 5 Color 04 Yellow 32 39 20 27 13 15 5 Color 05 Green 40 47 28 2F 16 18 5 Color 06 Turquoise 48 55 30 37 19 21 5 Color 07 Cyan 56 63 38 3F 22 24 5 Color 08 Blue 64 71 40 47 25 27 5 Color 09 Lavender 72 79 48 4F 28 30 5 Color 10 Mauve 80 87 50 57 31 34 5 Color 11 Magenta 88 95 58 5F 35 37 5 Color 12 Pink 96 103 60 67 38 40 5 GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 14 6 P BOO XL RZ RGE Channel Function Time and Value DMX HEX White CTO Color temperature 104 111 68 6F 41 43 5 3200K White Color temperature 112 119 70 77 44 46 5 5600K White CTB Color temperature 120 127 78 7F 47 49 5 7200K Rainbow Effect Stop 7 128 80 50 Rainbow Effect slow fast 129 223 81 DF 51 88 Rainbow Effect random colors slow fast 224 255 E FF 89 100 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9
9. present PFC voltage Manual Version 1 2 from Software Version 1 01 03 02 10 DOWN UP Aq Fae 200 XL RZ RGE EC ssion P d LED PWM Vers 1 Shows Dimmer 1 Software Version LED PWM Vers 2 Shows Dimmer 2 Software Version LED PWM Vers 3 Shows Dimmer 3 Software Version Pos Feed Tilt Delta Internal data and function diagnose Temperate Indicates the present arm temperature Arm Temperature Indicates the present head temperature Head PAN TILT Switches power for Pan Tilt ON or OFF Motor Power disconnected from power PAN TILT i Silent Mode Reduces maximum speed for Pan Tilt Defines whether the last DMX signal is stored or DMX Hold the lamp is switched OFF in case of signal interruption Position Automatically position feedback correction for Feedback Pan Tilt movement Adjustments for a uniform white color white uus casi et balance only in white mode Red Input for red adjustments Blue Input for blue adjustments Green Input for green adjustments Set DMX Image Stores the Scene currently sent to the unit DMX input Indicates the presently received DMX signal per Monitor DMX channel Pan Instantaneous value for Pan Speed Speed adjustment for Pan Tilt movements Movements see item below Pan Tilt Movements Instantaneo
10. 01 01 01 01 0 5 1 90 02 03 02 03 1 0 1 180 04 05 04 05 1 7 1 270 06 07 06 07 2 5 PAN 2 0 08 09 08 09 3 3 2 90 10 11 0A 0B 4 1 2 180 12 13 0C 0D 4 9 2 270 14 15 OE 0F 5 7 PAN 3 0 16 17 11 11 6 5 3 90 18 19 12 13 7 3 3 180 20 21 14 15 8 0 3 270 22 23 16 17 8 8 PAN 4 0 24 25 18 19 9 6 4 90 26 27 1A 1B 10 4 4 180 28 29 1C 1D 11 2 4 270 30 31 1E 1F 12 TILT size phase see also PAN 32 63 20 3F 13 25 PAN TILT size phase see also PAN 64 95 40 5F 26 37 PAN TILT inverse size phase see also PAN 96 127 60 7F 38 50 Circle size phase see also PAN 128 159 80 9F 51 62 Circle inverse size phase see also PAN 160 191 AO BF 63 75 GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 13 6 P EC ssion P d 200 XL RZ RGE Channel Function Time and Value DMX HEX Lying eight size phase see also PAN 192 223 C0 DF 76 87 Random movement size see also PAN 224 255 EO FF 88 100 14 Speed Pan Tilt relative movement 0 1 00 01 0 0 5 Pan Tilt Pan Tilt slow fast Pan Min 660 200s 2 255 02 FF 1 100 Use this channel 14 also for the speed Pan Max 660 of the movements channel 13 Tilt Min 300 110s Tilt Max 300 15 Zoom Steplessly adjustable Zoom 10 26 0 255 0 FF 0 100 Max Pow
11. 3 Level 4 Remark DMX Start Address Define the DMX start address 001 Special Manual DMX Manual control of all system functions Pan Manual control for Pan X movement Speed Speed adjustment for Pan Tilt movements Movements see also item below Pan Tilt Movements Manual control for Pan Tilt movement Special Activate the White or Full Power Mode see P also DMX table White Temperature Adjustment of the white color temperature Dimmer Manual control for dimmer Shutter Manual control for shutter Blue Manual control for blue Green Manual control for green Red Manual control for red Color Wheel Manual control for the color wheel Tilt Manual control for Tilt Y movement Zoom Manual control for Zoom Display Contrast Adjustment for the Display contrast Default Set Resetting all functions to original values Set Dimmer Changes PMW frequency between 600Hz and Frequency 1200Hz LED Dimmer Reads out the current LED dimmer software Version version ImpressionXL 300 Version Reads out the current CPU software version Key code Use the code for entering the calibration menu Adjust XXXX for authorized persons only Pan Offset Calibration for Pan Offset Tilt Offset Calibration for Tilt Offset Clear EEPROM Erase EEPROM memory Diagnose Diagnose functions GLP German Light Products GmbH Pos Feed Pan Delta Internal data and function diagnose oix Ti nt internal data and function diagnose PFC Voltage Show the
12. 5 Random Pulse effect slow fast 16 47 10 2F 6 18 5 GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 1 5 0 255 0 255 00 FF 00 F F 0 100 0 100 200 XL RZ RGE Channel Function Time and Value DMX HEX Up dimming then Shutter closing slow fast 48 79 30 4F 19 31 5 random patterns Shutter open then down dimming slow fast 80 111 50 6F 32 43 random patterns Up dimming then down dimming slow fast 112 143 70 8F 44 56 random patterns Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1Hz 10Hz 200 239 C8 EF 78 94 Shutter open 240 249 FO F9 95 97 5 RESET Min 3 Sec 250 FA 98 Shutter open 251 255 FB FF 99 100 12 Dimmer Dimmer 096 10096 0 255 0 FF 0 100 coarse 13 Dimmer Dimmer Low 0 255 O FF 0 100 fine 14 Zoom Steplessly adjustable Zoom 10 26 0 255 0 FF 0 100 The predefined colors can be used as start colors for the Rainbow effect First select a desired start color then activate the rainbow effect All IMPRESSION 300 XL RZ RGB will then begin from that color and execute the rainbow effect synchronously Different IMPRESSION 300 XL RZ RGB can have different start colors but will still execute the rainbow effect synchronously If you choose a color different from the one
13. act type plug Powercon Connected load 1200 VA W lt gt T15A micro fuse 6 3x32mm Please see printing on the case for the correct mains supply Disconnect from the mains supply for changing the fuse and use only the above described micro fuse type 2 89 DMX USITT DMX 512 Standard input output in 3 pole and 5 pole connectors 3 pole Pin 1 Ground Pin 2 Pin 3 5 pole Pin 1 Ground Pin 2 Pin 3 Pin 4 5 n c The DMX Addressing starts at the DMX Address 001 3 The Menu Field You ll find the control board on the side of the arm It allows you to make all necessary adjustments of the IMPRESSION XL With the Mode key you get into the main menu Afterwards you can navigate through the menu with the Up Down keys Push the Enter key to get to the next menu level or to confirm your settings Select ON OFF function settings with the Up Down keys Con firm and save with the Enter key the display shows OK Push the Mode key to cancel the entry and go back to Mode Enter the main menu Scroll wheel Up amp Down GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 9 DOWN UP 6 pez BOO XL RZ RGE MODE ENTER gt EC lor P d Level1 Level 2 Level
14. an be mounted directly to the bottom of the base using the four Camlock connectors GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 2 1 3 Mounting in sideway position To operate the IMPRESSION XL in a sideways position please use an additional mounting bar available from GLP or one of their agents This mounting bar is fixed via the four camlock quick release connectors Two half couplers or clamps are then used to hang the mounting bar This technique is necessary to cope with the additional torque in this mounting position Never use the Mounting in hanging position technique described above to secure the fixture in a sideway position as the fixtures base can become damaged and a secure installation cannot be assured Without mounting bar GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 200 YL RZ RGE 2 2 Securing the Device Regardless of the mounting method of the IMPRESSION XL you ll have to use a secondary safety wire This safety wire can be attached to the fixture by threading it through one of the two holes provided on the base of the fixture Ensure that the safety wire is securely fastened through the fixture and the fixtures mounting support Install a safety wire that can hold at least 10 times the weight of the fixture 2 3 Connections 2 83 1 Power Supply 7100 240 Volt AC 50 60 Hz earth cont
15. e LCD display XXIXIXX 06 600Hz 12 1200Hz N Normal Mode C Compressed Mode H High Res Mode N Tilt normal Tilt inverted N Pan normal Pan inverted 5 Maintaining and Cleaning the IMPRESSION 300 XL RZ RGB The IMPRESSION 300 XL RZ RGB is a low maintenance fixture It is only necessary to clean the air inlets and outlets as well as the optical LED lenses from time to time For safe operation it is absolutely essential that the fixture is kept clean and that dust dirt and smoke fluid residues must not build up on or within the fixture If they do the fixture s light output will be significantly reduced and damages to the fixture may occur Regular cleaning will not only ensure the maximum light output but will also allow the fixture to operate reliably throughout its entire life A soft lint free cloth moistened with any good glass cleaning fluid is recom mended Under no circumstances should alcohol or solvents be used to clean the fixture or its lenses 5 1 Safety regulations e Disconnect the fixture from the mains power before commencing any maintenance work e Wait minimum 15 minutes after removing the power to allow the fixture to cool down 5 2 Maintenance Intervals rule of thumb The maintenance schedule of any given fixture depends on the installation environment Hence no specific guidelines can be given The cleaning intervals given below are suggestions based on practical experie
16. ed in chapter 2 of this manual Operating the IMPRESSION 300 XL RZ RGB without suitable mounting devices can increase the risk of an accident The IMPRESSION 300 XL RZ RGB features a unique small and lightweight design with no specific carrying handles Care needs to be shown when handling the fixture to ensure that no unnecessary damage should occur Fragile areas include the LCD display and cover on one side arm and the front bezel Pressure in these areas could result in damages which will not GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 5 rap 300 XL RZ RGE be covered by the standard warranty 10 Repair maintenance and installation work should only be performed by qualified or GLP certified staff You need to pay attention to the common rules of technology that are not explicit mentioned in this manual 11 Use only original spare parts Any structural modification on the system will terminate all warranty claims 12 Please keep this instruction manual for future reference 2 Preparation and Installation 2 1 Mounting The IMPRESSION 300 XL RZ RGB is fully operational whether it hangs or is mounted to a wall It can also be operated while standing on the floor Keep a safety distance of 0 5 m from any easily inflammable materials decoration etc S a zem 4 FE E N 7 NA NS J EN J Y J SS y f Z X X X j ZR 3 NI A HC NIE IA
17. er Mode vs White Mode The IMPRESSION 300 XL RZ RGB can use the white balance adjustments for each individual color setting Whether the White Mode is used with RGB can be selected in the Normal DMX Mode by using the Special DMX channel If the Special channel is set to a value between DMX 0 15 the White Mode is not used and the RGB goes for the maximum light output If the Special channel is set to a value between DMX 16 31 the white balance is used for the RGB output Since there is no Special DMX channel in the Compress DMX Mode the possibility exists to likewise select these settings also in the display menu If the White Mode is set to ON the white balance is activated If the White Mode is set to OFF the RGB goes for the maximum light output Max Power Mode The continuous color temperature correction is applicable only for the White color i e if this function is selected DMX 2 001 the IMPRESSION 300 XL RZ RGB will change the color to white immediately and will then be adjustable in the color temperature in a range between 3200K and 7200K Hence a color correction for others than white is not intended Compress Mode 10 DMX channels Channel Function Time and Value DMX HEX 96 1 PAN 0 660 0 255 00 FF 0 100 coarse 2 PAN fine High Pos High Pos 2 6 16 Bit 0 255 00 FF 0 100 3 Tilt 0 300 0 255 00 FF 0 100 coarse 4 Tilt
18. mer 0 100 DMX Control Standard USITT DMX 512 3 5 pole XLR Pin 3 2 Pin2 Ground Pin 1 DMX Addressing starts at the DMX channel 001 Pan Tilt 8 16 Bit 3 phase stepper motor Pan movement 660 Position Feedback Tilt movement 300 Position Feedback Weights and Measures Width of the base 521 mm Length of the base 217 mm Height head vertical 550 mm Fixture weight net 23 5 kg Floor Mount weight 2 kg net GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 18 200 XL RZ RGE 7 Index B oie Aon TR 6 C Circumference sssseeeeeeeenee 17 Cleaning itis eee ke pe teas 17 Compress Mode 14 15 D Description of Device 4 DIN WDE 0711 2175 etes 6 DMX tite tte toe toten bcn Mathe 9 E amp mallzzzitcii iiber E eer ELEM LN eie re 1 merkea srt ts ccecties 3 tris eue 9 EVClCIS wisi eter iiie tam 7 H Half couplers clamps seessssss 8 I Interneti niam na eee as 1 K Key C ecra pu gtubeesmaSiehaiines 10 L LED Glass 2M iiri reete da bi vn ac radar ni 5 M Maintenance eese 17 Manual Version eeeeeeeee 1 Max Power Mode sss 14 MICrO fUSG ient oec rez Ente 9 Mode key eee ipee 9 Mounting eret 6 GLP
19. nce We suggest that you start with these and develop your own maintenance schedule as you see the fixtures performance in your specific environment Maintenance Task Interval How Cleaning of LED lenses and weekly soft brush lint free cloth optical system Cleaning of fans and air channels monthly vacuum cleaner airbrush etc GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 17 b so VILPZPGR DEE Attention e Never let optical parts come into contact with oil or fat e Before running the fixture wait until all parts are touch dry e Never touch lenses with bare fingers 6 Technical Specifications Power supply Power consumption 1200 VA Watt Power Input 7100 240 V AC 50 60 Hz auto sensing input Fuse protection Micro fuse 6 3x32 mm T15A Operational Parameters Max Ambient 45 113f integrated overheating switch Temperature Mounting Position Any see chapter mounting Lighting System Additive Color mixing LED Type 297x Luxeon Rebel High power LEDs Lifetime 50 000 h 105 red 96 green 96 blue LEDs wavelength optimized for maximum presentable color space Optical System High efficient Collimator cluster Steplessly adjustable zoom 10 26 Scattering light aperture Shutter Dimmer 8 16 Bit Strobe Effect with variable speed between 1 10 flashes per second Random Strobe Pulse Effects Continuous Dim
20. s marked with in the tables above the rainbow start color will be red Rainbow effect Stop will pause this function After resuming the rainbow effect will be continued with the current color The Rainbow effect will run synchronously only if it is started from one of the predefined colors see also before Locking and unlocking the Control Panel You can lock and unlock the control panel by pressing the menu keys MODE amp ENTER amp UP at the same time Additional shortcut features when switching on the fixture a 1200Hz Mode Hold down the UP button during power ON After switching on the fixture the LEDs will be operated with a Pulse Width Modulation PWM of 1200Hz In addition all standard settings will be loaded DMX start address 001 Normal Mode b 600Hz Mode Hold down the DOWN button during power ON After switching on the fixture the LEDs will be operated with a Pulse Width Modulation PWM of 600Hz In addition all standard settings will be loaded DMX start address 001 Normal Mode GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 16 p soo VL EZREE Gto c Standard Mode Hold down the ENTER button during power ON After switching on the fixture the DMX start address will be set to 001 All other settings will remain unchanged Additional Display Indications As a default you ll find the following additional information in the first row of th
21. ser manual Warranty claims will also be cancelled in the event of the system casing being opened Make sure that before powering up the fixture the fans and air inlets are clean and not blocked by anything Before powering up the fixture ensure that the moving head part of the fixture can rotate unhindered through its full range of movement A safety distance of at least 0 5 m to any easily flammable material e g decoration material must be adhered to Attention Don t touch the device during operation Parts of the fixture can become hot and can cause injuries and or damages The system doesn t contain any user serviceable parts Opening the fixture Will void the manufacturers warranty Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay attention to possible hot parts of the system Never look directly into the beam of light or one of the LEDs Never use optical apertures with a distance less than 0 5 m to observe the beam of light LED Class 2M Not following these precautions can result in serious injury to your eyes and in particular your retina Attention LED Class 2M can cause injuries of your eyes even without optical instruments in front of them or within a distance of less than 0 5m and short exposure time Avoid direct radiation to your eyes To ensure proper operation you must also follow the installation guide describ
22. us value for Pan Tilt movements Special Instantaneous value for Special White Temperature Adjustment of the color temperature for WHITE Dimmer Instantaneous value for dimmer Shutter Instantaneous value for shutter Blue Instantaneous value for blue Green Instantaneous value for green Red Instantaneous value for red Color Wheel Instantaneous value for Color Mixing unit Tilt Instantaneous value for tilt movement Manual Version 1 2 from Software Version 1 01 03 02 1 1 GLP German Light Products GmbH DOWN UP 6 pem Zoom Self Test Live time Display Blackout Select DMX Mode Compressed Normal High Resolution White Mode Reverse Pan Reverse Tilt Reset 4 DMX Channel Sheet Normal Mode 14 DMX channels 200 XL RZ RGE Instantaneous value for zoom Starts a self test procedure of the device Indicates the overall operation time of the system Adjust the display ON OFF Display OFF Please select the desired DMX Mode Fixture works in Compressed mode gt see also sectiion 4 Fixture works in Normal mode gt see also section 4 Fixture works in High Resolution mode gt see also section 4 ON OFF Adjustments for white balance are activated Selects Inverse Pan on or off SelectsInverse Tilt on or off RESET all functions Channel Function 1 PAN

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`application pour le contrôle des mouvements    Samsung SM-G530MU manual do usuário(OPEN)  ficha técnica serie oro revestimiento elastomero liso fungicida 012  AVH-P6850DVD Baixe  T-100 - Fantek  Guida per l`utente  PCR1447 - selek.com.br    TaskLink™ for Windows® User Manual UniSystem Programming  

Copyright © All rights reserved.
Failed to retrieve file