Home
        pH100 - Global Water Instrumentation, Inc.
         Contents
1.  year from date of shipment  a six month limited warranty applies on sensors and  cables   If it should become necessary to return the instrument for service during or beyond the warranty  period  contact the Customer Service Department at  781  890 7440 ext  210 for authorization or visit our  website at www extech com  click on    Contact Extech    and go to    Service Department    to request an RA  number   A Return Authorization  RA  number must be issued before any product is returned to Extech  The  sender is responsible for shipping charges  freight  insurance and proper packaging to prevent damage in  transit  This warranty does not apply to defects resulting from action of the user such as misuse  improper  wiring  operation outside of specification  improper maintenance or repair  or unauthorized modification   Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and  will not be liable for any direct  indirect  incidental or consequential damages  Extech s total liability is limited  to repair or replacement of the product The warranty set forth above is inclusive and no other warranty   whether written or oral  is expressed or implied     a  Support line  781  890 7440  Technical support  Extension 200  E mail  support extech com    Repair  amp  Returns  Extension 210  E mail  repair extech com    Product specifications subject to change without notice    For the latest version of this User   s Guide  Software 
2. 2 to 194  F  0 to 90  C     Temperature Range 23 to 194  F   5 to 90  C   Temperature Resolution 0 1   up to 99 9 then 1   thereafter  Temperature Accuracy   1 8  F   1  C  from 23 to 122  F   5 to 50  C        5 4  F   3  C  from 122 to 194  F  50 to 90  C      Measurement storage 15 tagged  numbered  readings    Power    Four  4 CR2032 button batteries    Low battery indication    BAT    appears on the LCD    Auto power off After 10 minutes of inactivity    Dimen    sions 35 6x172 7x40 6mm  1 4x6 8x1 6      110g  3 8502     Optional Accessories    Note    Tripak buffers with 4  7  amp  10 pH capsules  6 each  plus two rinsing solutions  Part  Number  PH103     pH 4 01 buffer  pint   Part Number PH4 P    pH 7 00 buffer  pint   Part Number PH7 P    pH 10 00 buffer  pint   Part Number PH10 P    Spare pH Electrode     non refillable  Part Number  PH105   Spare pH Electrode   refillable  Part number PH115   Electrode Refill solution  Part number PH113    Spare ORP electrode  Part Number  RE305    Spare Chlorine electrode  Part Number  CL205    Weighted base with 5 solution cups  Part Number  EX006   DO600 1C 3ft  extension cable    DO600 5C 16ft  extension cable      If the unit is to be converted for ORP or Chlorine use by attaching the proper  electrode  please visit www extech com to download the proper User Guide    7 PH100 PH110 Version 5 0 06 05    Warranty       EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and  workmanship for one
3. User Guide    EXT    INSTRUMENTS       ExStik    pH Waterproof Meters  Models PH100  amp  PH110  Patent Pending                   ExStik    Description       Front Panel Controls             1  Battery compartment cap 1   2  LCD Display   3  MODE  HOLD button EXTECH   4  CAL  RECALL button     5  ON OFF button 43 2   6  Electrode collar 236    7  Electrode  refillable on PH110  ExStik    Electrode cap is not shown  W 3  EA 4  2 5   6  Display    1  Bargraph reading  2  Measurement reading    3  BAT  low battery  and  HOLD  data hold  indicators    4  Temperature display   5  Bargraph scale designations  6  Units of measure   7  Calibration indicators 4 3  8  RENEW and CAL indicators g 4       2 PH100 PH110 Version 5 0 06 05    Overview       pH Overview    pH is a unit of measure  ranging from 0 to 14pH  indicating the degree of acidity or  alkalinity of a solution  pH tests are the most commonly performed measurements in water  analysis and reports the negative log of the hydrogen ion activity of a solution which is an  indicator of acidity or alkalinity  Solutions with a pH less than 7 are considered acidic   solutions with a pH higher than 7 are known as bases  and solutions with a pH of exactly 7  are neutral     The pH scale is logarithmic so  for example  if sample A is 1 pH less than Sample B  this  means that Sample A is 10 times more acidic then Sample B  A difference of 1 pH  represents a ten fold difference in acidity     Getting Started    Remove the cap from the 
4. bottom of the ExStik    to expose the electrode glass surface  and reference junction   Before first use or after extended storage  soak the electrode  with its cap removed  ina  pH 4 solution for about 10 minutes  PH100 only     White KCL crystals may be present in the cap  These crystals will dissolve in the soak or  they can be simply rinsed with tap water    Always calibrate close to the expected measurement value   Before first use  twist off the battery compartment cap to access the battery  Locate and  remove the plastic battery insulating tab    A sponge is located in the electrode protective cap  Keep this sponge soaked with a pH 4  solution to preserve Electrode life during storage    Replacing Electrodes    The ExStik    is shipped with an electrode attached  Electrode life is limited and is   dependent on  among other factors  frequency of use and care  If the electrode needs to   be replaced  follow these steps for removing and connecting electrodes  Note that the   PH110 has a refillable electrode and the PH100 does not    1  To remove an electrode  unscrew and completely remove the electrode retaining  collar    2  Gently rock the electrode from side to side  pulling it away from the meter  until it  disconnects    3  To attach an electrode  carefully plug the electrode into the meter socket  note that  the electrode connector is keyed  ensuring proper connection     4  Secure the electrode in place by tightly turning the collar in place   a rubber gasket  seal
5. ctrode only     Refillable l  pH Module y       The refillable electrode does not need to be detached from the  body of the ExStik    in order to perform the refilling procedure   Refillable electrodes  PH115  have a removable reference junction   slotted  and the word REFILLABLE on the side of the electrode  housing        Removing the Reference Junction  The removal tool supplied with the       PH113 Refill Kit is used to remove     the reference junction from the   sensing surface of the electrode  If   the reference junction does not have Junction removal tool        slots for the    teeth    of the removal  tool to lock onto  the electrode is  NOT refillable  Reference junction    Holding the electrode upside down  unscrew and remove the reference junction using the  removal tool     Filling the Electrode    1  Once the reference junction i  is removed  fill the cavity with the refill solution  supplied in the Refill Kit     2  Replace the reference junction using the removal installation tool   Spare junctions  are provided if needed      Filling Solution    The supplied container includes 15ml of filling solution  There is enough solution for 4 to 5  refills  Use only the supplied solution for refilling the electrode     6 PH100 PH110 Version 5 0 06 05    Specifications       Display Multifunction LCD with Bargraph  Operating conditions 32 to 122  F  0 to 50  C     lt  80  RH  Range and Accuracy 0 00 to 14 00     0 01pH typical    Temp     Compensation Automatic from 3
6. icon appears on the LCD indicating that the ExStik    may require calibration  Some  applications may require recalibration of the electrode more frequently than others  The  CAL display is simply a reminder and will turn off when the pH electrode is recalibrated     RENEW Display  A flashing    RENEW    warning indicates that the probe may be nearing the end of its useful  life  If cleaning or recalibration does not cause the RENEW icon to disappear  replace the  electrode  The RENEW display appears when the output of the pH electrode fails a  diagnostic test     Considerations    If the unit appears to be locked  display frozen  it is possible that the Data Hold mode  has been inadvertently accessed by pressing the MODE button  Simply press the  MODE button again or turn the meter off and restart if the display appears frozen     If the meter does latch up and no button presses revive it  remove the batteries  push  the ON button for 3 seconds and then reinsert the batteries    Note that if the batteries are removed  any stored readings will be discarded  Also  the  user calibration data for pH will be cleared  New user pH calibration data is required   Factory calibration data for all models will be retained  however     5 PH100 PH110 Version 5 0 06 05    Battery Replacement       1  Twist off the battery compartment cap  2  Replace the four  4  2032 batteries observing polarity   3  Replace the battery compartment cap       PH Electrode Refilling  0H110 115 refillable ele
7. nizes the solution and calibrates itself to that value   Note  If the solution is more than 1pH off from the 4  7  or 10pH standard  the  ExStik    will assume an error and abort the calibration  CAL and END will be  displayed    3  During calibration  the pH reading flashes on the main display    4  When calibration is complete  the ExStik    automatically displays    END    and returns  to normal operation mode    5  The appropriate circled indicator         or    will appear on the LCD when a  calibration has been completed  The calibration data is stored until a new calibration  is performed    6  Fora two or three point calibration  repeat steps 1 4    Note  Always turn the meter off and then on before calibrating to allow sufficient time to  complete the calibrations during one power cycle  If the meter auto powers off during  calibration the calibrations remain valid  but new calibrations will turn the circled  indicators off     Changing the Displayed Temperature Units    Press and hold the CAL button for approx  3 seconds  The   C or   F icon will change first  and the numerical temperature value will change after the button is released  If the  Calibration mode is accidentally accessed    CAL    appears on the LCD  Simply turn the  ExStik    off and start again     Data Hold    Momentarily press the MODE button to freeze the current reading  The HOLD display icon  will appear along with the held reading  The held reading will also be stored in memory   Momentarily p
8. ress the MODE key to return to normal operation     4 PH100 PH110 Version 5 0 06 05    15 Storing Readings into Memory    1     Momentarily press the MODE button to store a    reading  The LCD will briefly display the se y  memory location number and then the value ig    pH  stored  Data Hold will activate   y4   gt  g i 4       20                   Momentarily press MODE again to return to      How  normal operation  q 8 6   Repeat step 1 to store the next reading and so   on    After 15 readings are stored the ExStik    will return to memory location 1 and start    overwriting existing data with newly stored data     Recalling Stored Readings  Note  Check that the HOLD symbol is not displayed  If it is  exit the HOLD function by    i     momentarily pressing the MODE button    Momentarily press the CAL button and then press the MODE button immediately after  CAL is displayed  the storage location number  1 through 15  will flash  If the CAL  mode is accidentally accessed  display flashing   press the CAL button again to exit   The last reading stored will be displayed first  To advance through the stored  readings  momentarily press the MODE button  The location number is displayed first   followed by the reading stored in that location    To exit the recall mode  momentarily press the CAL button and the ExStik    will return  to normal operation     CAL Reminder Display  When the ExStik    is turned on in the pH mode for the 15th time without recalibration  the     CAL    
9. s the electrode with the meter      Automatic Electrode Recognition    When the ExStik    is turned on  it recognizes the type of electrode that is connected and  displays the appropriate unit of measure  Attach electrode before turning the ExStik    on     Powering the ExStik       If the batteries are weak  the    BAT    indicator appears on the LCD  Press the ON OFF key  to turn the ExStik    on or off  The auto power off feature shuts the ExStik    off  automatically after 10 minutes of inactivity to preserve battery life     3 PH100 PH110 Version 5 0 06 05    Operation       Overview    When the electrode is placed in a solution  the main display and bargraph indicate the pH  reading while the lower display reads temperature  readings flash until they have  stabilized   The bargraph is    center zero     i e  at pH 7 there is no display  As the pH rises   the bar moves from the center to the right  If the pH drops  the bar moves from the center  to the left     pH Calibration  1  2  or 3 points   A two point calibration with a buffer of 7 plus 4 or 10  whichever is nearest to the expected  sample value  is always recommended  A one point calibration  choose the value closest  to the expected sample value  is also valid  For best accuracy  always calibrate at the  sample temperature     1  Place the electrode into a buffer solution  4  7  or 10  and momentarily press the CAL  key  pH 7 should be calibrated first  then 4 and or 10 pH    2  The ExStik    automatically recog
10. updates  and other  Up to the minute product information  visit our website  www extech com       Copyright    2005 Extech Instruments Corporation   All rights reserved including the right of reproduction in whole or in part in any form     8 PH100 PH110 Version 5 0 06 05    
    