Home
iStars User Manual EN
Contents
1. 2 1 2 UPS Real time Data UPS Real time Data mainly displays the Real time value of UPS data Current Location UPS Status Info gt Real time Data Real time Data Battery Information Input Information Battery Temperature C Input Frequency Hz Output Voltage Y Output Information Output Load CX Bypass Frequency Hz Bypass Information 1 11 Figure 3 4 Page of UPS Real time Data UPS Communication Status Display connection of UPS and Stars webpage Real time Data This mode contains Battery information Input information Output information Bypass information Page displays information will be slightly different depending on the communication protocol Figure 3 4 UPS real time data is the page of EA three protocols IStars 2 1 3 UPS Real time Status UPS Real time status shows whether there is any abnormal phenomenon under various working status of UPS Current Location UPS Status Info gt Real time Status Real time Status UPS Communication Status Communication OK Battery End of Discharge Battery Information Output Information System Information Figure 3 5 Page of UPS Real time Status UPS Communication Status Display connection of UPS and iStars webpage UPS Real time Status This mode contains Battery information Input information Output information Bypass information System information Page displays information will be slightly different depending on the com
2. 3 Input the username and password click and confirm to enter into the monitoring page An initial account with default username admin and passwords admin is set User can add or delete corresponding user account and authority in setting pages Welcome User name admin Password esses Remember my password L ox Ji cancel Figure3 1 Webpage Login Interface of iStars IStars Section2 UPS Web Interface After entering into iStars webpage current login username and its authority system functional menu and status will be displayed in home page There are four items for major functional options of system menu 2 1 UPS Information and Status 2 2 Setting and Control 2 3 Log Query 2 4 Assistant Function System Menu E System Information and Status iStars Information tu UPS Information and Status System Name iStars Hardware Version iStars_HWV2 0 fof E Basic Information System Administrator Admin Firmware Version iStars_SWV3 55 ie io ye System Location Location S N U20130319080009 E UPS Real time Data System Time 2013 04 01 09 07 10 E UPS Real time Status E Graph Display Total Running Time 4 day 18 42 33 HO Setting and Control E UPS Setting E UPS OWOF Settings gt E Network Setting UPS Last Selftest Time UPS Load Limit 100 UPS Next Selftest Time UPS Temperature Limit C 80 0 Email Daily Report Time UPS Low Voltage Alarm 10 NO Shutdown UPS Ahead of 30 Minut
3. Stars SNMP Web Card User Manual Ver 1 1 IStars CONTENTS CONTENTS orar id dead 1 CHAPTER OVER VIE Wind aa a a a is 2 CHAP TERZ INTRODUCTION scada 3 SECTION DESCRIPTION OF HARDWARE cccccccecccecceceeeececeueeeeeeeueeeeeueueeeuueeaeeueeeueeuneeensuneeass 3 SECTIONZ DISK INFORMATION Lai id 4 CHAPTER3 UPS WEB MANAGEMENT cccsscccceseeceesecenseeceaseecenseseensesenseeseasenenneees 5 SECTION INTRODUCTION dd e dd 5 SECTIONZ UPS WEBINTERFACE standard alain sitios 6 2 CUPS MESS IT and IUU ii A A a id 7 ZA UPS Basio IMOlMallO ratas ita a ai 7 2 12 WP Ome time Data an heed esas 8 2123 WPS Realtime Status di aa 9 2 E ae tstaca Stein a a E 9 ZZ oeus ano CON O dais 10 22 1 REME CONTO nani rl iii 10 222 UP SOEN S ensen a OOO 12 223 WPS Oli OW SENINGS eie E A tada 15 2 2 4 NEIWOIK SCWINGS state 15 AS o a a 17 2 2 0 EMall CLG Screen rec OA ri etc bad 18 2 2 FOMS DOUG S e caco 20 220 ESIIMOd Bss tn aee e salidos 21 SS SUING Sas etd eS i a a p 22 23 POCONO QUIY ti A A ans ney A tii 24 al EVEN LO rta 24 A San 25 2 URSS Dato o eee 25 ZAS SIS ANT FUNCHON id id a 26 2AT Firmware Udala 26 2420 DEDO eos E E NAN 27 ZA Y AP o no PO 28 IStars CHAPTER1 OVERVIEW Stars is new generation network monitoring product Not only could monitor UPS stand alone Stars also could real time network monitor and man
4. relevant information of iStars external GPRS module Message Settings Message setting includes network system settings and sending message wh en UPS is abnormal Phone Number 1 8 Set mobile phone number of receiver Selected 20 IStars It can select partial or all events detected by iStars to send to the setting Mobile phone number and detailed events can be seen in Figure 3 15 UPS Event Page Test Settings Test the mobile phone of message receiver and whether mobile phone number of receiver can receive the message The receiver will receive a test message if the function is ok 2 2 8 T amp H Module T amp H Module includes communication status real time data as well as upper and lower li mit setting function T amp H Module and Message Seiting can t be used simultaneously Current Location Setting and Control gt THS Module THS Module Communication Status Upper Limit of Temperature C Lower Limit of Temperature C Apply Figure 3 16 Page of T amp H Module Communication Status Display the communication status between T amp H Module and Stars Real time Information Display real time data and status of temperature and humidity Set Set upper and lower limits of temperature and humidity A IStars 2 2 9 System Settings System settings page is used to set parameter of iStars including system configurations system time language setting and port setting System Setting System Nam
5. and system settings 0 4 set use actual according to UPS protocol Management of Enabled Battery Using SNMP to calculate the remaining battery capacity and battery time is limited to part of the agreement Battery Parameters Setting as follows sioe IStars Cell Hight Voltage V 1 0U CN O METE ETT CO ETT CS Ca O ETT Battery Hight Current Battery Low Terminate Current Figure 3 9 Page of Battery Setting UPS Records This table sets the time interval of record for UPS UPS Testing Interval Not self test self test once a week and self test once two week is available Once not self test option is active other settings in this table would be unavailable Otherwise when self test once a week or self test once two week is set UPS testing time per week UPS self test time and UPS test type are configurable UPS Testing Time Per Week You can determine UPS self testing in which day every week or every two weeks UPS Self test Time You can determine UPS self testing time of the setting day UPS Test Type You can choose UPS self test 10 seconds self testing until Battery voltage low or self testing for setting time The value should be integer between 0 and 99 e le IStars Alarm Settings This table is used to set the limits of alarm It will give alarm when related value of UPS reaches the set value of alarm The Alarm setting contains UPS failed to come online over time UPS load limit UPS temperature lim
6. it is sent to are recorded Records can be inquired monthly Current Location Log Query gt SIMS Log SMS Log Query Date 201311 lt 0 0 gt Figure 3 19 Page of SMS Log 2 3 3 UPS Date Log In this page the input voltage output voltage input frequency bypass frequency output frequency load capacity and temperature of UPS can be recorded according to the set time of UPS data record in page of UPS parameter set Inputting the enquired year month and date the UPS data record of a specific day can be derived Data can t be inquired when the time does not exist Date Time Record corresponding date year month date and time hour minute second of data record Input Voltage Record the input voltage of UPS Output Voltage Record the output voltage of UPS Input Frequency Record the input frequency of UPS Bypass Frequency Record the bypass frequency of UPS Output Frequency Record the output frequency of UPS Load Record the load of UPS 295 2 iStars Capacity Record the capacity of UPS Temperature Record the temperature of UPS Current Location Log Query gt UPS Data Log UPS Data Log Querr Date 20131128 Apply Figure 3 20Page of UPS Data Log 2 4 Assistant Function Assistant Function includes firmware update port debug and about 2 4 1 Firmware Update This page is used to set update of related firmware including version local update and FTP update Accordi
7. RS and T amp H However between GPRS and T amp H only one can be chosen because GPRS is message port and T amp H is T amp H Module port AN Please according to the actual port of UPS to choose the correct configuration set improperly may cause abnormal communication Port RS232 port or RS485 port Baud rate 1200 2400 4800 9600 19200 38400 and 57600 Data Bits 5 8 data bits Parity no parity odd even Space Parity and Mark Parity Stop Bits 1 2 stop bits e IStars 2 3 Record Query There are three sub functional options under this main functional option event log SMS log and UPS data log In this functional option it can enquiry certain historical records by inputting year and month and date all records will be saved in the iStars system for one year and it can save related record information in the computer by button of save in the page 2 3 1 Event Log In this page the date time and description of UPS event is recorded If you want to check the event record of one month input an integer with 4 bits for year integer with 2 bits for month Current Location Log Query gt Event Log Event Log Query Date 201311 Apply Figure 3 18Page of Event Log Date Time Record the date year month date and time hour minute second of UPS event Event Description Record detailed content of UPS event 24 IStars 2 3 2 SMS Log In this page the content of SMS the time and which mobile
8. agement of UPS Integrated monitoring can be achieved by coordinating corresponding PC software And it is quite convenient for User to take network management for UPS iStars provides very simple installation program It only needs to install the Search software attached by this product in PC after search or set the IP address of iStars by it it can land the page of iStars by browser with obtained IP to take further set iStars can remotely monitor the working condition and environment condition of UPS by internet Administrative personals can take remote monitoring of UPS by landing the internet to check real time status of UPS and know the working voltage current frequency temperature and humidity of UPS as well as know whether there is some fault for UPS iStars also can provide various operations for different operating systems It can according to detailed setting set the power off and test of UPS at some certain time set authority of login user username and IP etc lts main functions are 1 Set all functions by browser 2 Monitor real time status of UPS by browser 3 Support protocols such as TCP IP FTP NTP HTTP SMTP and SNMP etc 4 Provide IP search and updating tools iSearch 5 Send the daily report by Email 6 Send related information to administrative personals by Email of there is any fault for UPS 7 Add GPRS message module by request of user message module shall be purchased additionally IS
9. automatic setting is selected other contents in connecting status and IP address of DNS cannot be operated and all values in these two tables will be displayed according to the value of the software iSearch When manual setting is selected it can set the IP address subnet mask Gateway Address IP addresses of primary and secondary DNS Remote Login Page This table can set the name password permission and IP address of login of users Permission set contains no permission read and read write When no permission is selected the username password and IP address cannot be managed When user permission is set as readable the setting function saving function of record enquiry page firmware updating of auxiliary function page in iStars cannot be used When an IP is set the user only can login iStars under the IP If not set the IP address using the username can login iStars by any computer 16 IStars 2 2 5 SNMP Settings SNMP setting is used for Trap notice and SNMP protocol notice Current Location Setting and Control gt SNMP Setting SNMP Setting Oooo e o o DEI ORO INNATO INN sea EEN INNATA IES Se O INCA INTE INNATO ITA system will r d Figure 3 12 Page of SNMP Settings Trap Notice IP address of the recipient This function is set to receive IP address of Trap notification Users please set your own based on actual IP address Community This set value must be the same as that of receive compu
10. e System Administrator System Location Apply Note Change the system time may cause some records are set 3Hours v Web Y time nist gov v GMT 8 00 v Apply Note If you have disabled in your browser s cookies the below settings will not work Interface Language English v Email and SMS Language MW hd Apply Apply Figure 3 17 Page of System Setting System Configurations System Name Set the name of iStars this option can be named by user System Administrator Set the name of administrator of iStars System Location Set the location of iStars System Time Auto update interval This item is used to set the interval of update operation of the system Time Server This item is used to set the IP address of time server Time zone relative to Greenwich this item is used to adjust and set the time zone according to different countries GMT is the time in Greenwich De IStars means east zone and means west zone Auto Regulate lf this item is selected as yes the summer time will be changed automatically System Time This item is used for user to update the time manually Language Settings Web Language Seiting This table is language setting interface of iStars E mail SMS Update Language Settings This table is used to set the email or message written in English or Chinese when information is send to receive Port Settings Set the transfer port and type of iStars including port settings of UPS GP
11. es to Send Alarm as eee MAC Add 00 50 C2 F8 D3 32 E oe 5 ddress 50 02 Fo D3 po El E Connection Type 100Mbps Full duplex E Email Setting IP Address 192 168 6 6 E SMS Setting Subnet Mask 255 255 0 0 E E System Setti Gateway IP Address 192 168 0 8 1 Log Query i 2 E Event Log E SMS Log gt E UPS Data Log 0 Assistant Function E E Firmware Update E About ed 54 Ed Primary DNS Server Secondary DNS Server Time Server Email Server Login IP Address 192 168 0 84 192 168 7 228 Figure3 2 Homepage of Webpage of Stars IStars 2 1 UPS Message and Status UPS message and status mainly introduces general information and operation situation of UPS There are four sub function options UPS basic message UPS real time data UPS real time status graph display lt can support several communication protocols which will be introduced in chapter 2 2 setting and control 2 1 1 UPS Basic Information UPS basic information page contains UPS information and rating information Current Location UPS Status Info gt Basic Info Basic Info ICI ME CIN MEN Figure 3 3 Page of Basic Information UPS Information This table mainly introduces the manufacturer of UPS firmware version model and type and all this information will be transferred by UPS automatically Rated Information This table mainly displays rated information of UPS and will be transferred by UPS automatically IStars
12. it and UPS low voltage alarm 14 IStars 2 2 3 UPS On Off Settings This page mainly is used to set the on off time of UPS power supply It includes weekly time on off set special day on off set and other setting Current Location Setting and Control gt UPS Setting gt Bat etting Battery Setting CTI CA me Battery Hight Current Battery Low Terminate Current E CAN A Figure 3 10 Page of UPS On Off Settings On off settings On off setting in special day is prior to weekly timer on off settings That is when the weekly setting day and special day is the same day the on off setting day is the special day Other Settings The other settings include before time or special day shutdown send alarm Shutdown setting after a certain period of time under certain conditions such as off after the battery voltage is low latency off after over temperature off after overload 2 2 4 Network Seitings All related network information parameters can be set when iStars and UPS comminutes with network It contains connection status DNS server IP address and remote login page 15 iStars Setting and Control gt Network Setting Cn ON Primary DNS Server IP Address 8 8 8 8 Secondary DNS Server IP Address 61 28 10 68 ARA a R 192 168 169 3 Figure 3 11 Page of Network Setting Connection Status DNS Server IP Address IP obtaining method can be manual set or DHCP automatic setting When DHCP
13. lated event by Email when fault of UPS is detected Account Number 1 8 E mail account of receiver selected It can select partial or all events detected by iStars to send to the setting Email account and detailed events can be seen in Figure 3 14 UPS Event Page Current Location Setting and Control gt Email Setting gt Even Event Set Figure 3 14 Page of UPS Event Email Address of Recipient Receiving Daily Report Available Daily Reports Sent on Time This option is used to set whether sending daily log Account Number 1 4 Email account of setting receiving of daily log 19 IStars Test Set Test E mail Recipient It is used to set Email address of receive If the email function is ok receiver will receive a test mail 2 2 7 SMS Settings SMS Setting is similar with that of Email setting and iStars sends the data and events with form of short message It includes SMS communication status and SMS setting receive text messages by mobile phone test set Current Location Setting and Control gt SMS Setting SMS Setting E IT CI ECT CA EXT S Network Standard GSM v When the Event Occurs to Send Short Message Alarm vent Set Click to set the received alarm event types CC a E ee a CA Phone Number 4 Disable Control Figure 3 15 Page of SMS Setting SMS Status Display the communication status signal quality manufacturers and other
14. munication protocol Figure 3 5 UPS real time data is the page of EA three protocols 2 1 4 Graph Display Graph shows that the page displays related data of UPS including voltage temperatures and load etc with stopwatches and curves Furthermore you can check part displayed or not and all can be displayed in default iStars Current Location UPS Status Info gt Charts Charts Remaining Capacity X Battery Temperature C Output Load RCS Output Load_ X Input Voltage _R Input Yoltage_5 Input Yoltage_T Output Yoltage R bas Voltage_S ou Voltage_T pas Voltaze_R os Voltage Input Voltage _R V Input Voltage_S V Input Voltage T V Output Voltage R V Output Voltage V Output Voltage T V Bypass Voltage R V Vl Bypass Voltage S Figure 3 6 Graph Display of Single phase UPS 2 2 Settings and Control There are nine sub functional options for this item Remote Control UPS Setting Network setting UPS On Off Settings Network Setting SNMP Settings Email Setting SMS Setting and System Setting according to related information This function can t be opened to use for the users whose limit of authority is only readable 2 2 1 Remote Control This function is used to provide remote test control shutdown or restart of UPS Click and select the test item and then click button of apply to take related operation 10 IStars Current Location Setting and Control gt Remote Control Remote Cont
15. n be set as updating at specific time every day or every week Update Update option can update the version of firmware with Search by hand at any time After the progress of update firmware is finished 2 4 2 Port Debug TO display and export the UPS and GPRS port debug information OTs IStars Current Location Assistant Function gt Port Debug y RESPETE Play Mode Close Y Coding Type ASCII Y Port Type UPS v Export Debug Data Figure 3 21 Page of Port Debug 2 4 3 About This page records related information of Stars software Current Location Assistant Function gt About About iStars Stars is a new generation network monitoring product for UPS It provides realtime network management and UPS management Sincerely thanks all clients from home and abroad over the years the cooperation and support If you have any comments or suggestions please feel free to contact us We will strive to build a more perfect product Thank you Figure 3 22qpage of about 28
16. ng to network condition and the size of update package uploading files or firmware update may take several seconds or several minutes Please wait patiently When firmware version finishes updating iStars will automatic restart Warning don t power down during the restart process it may course the product doesnt work During the restart process the Monitoring Webpage can t react and iSearch can t search its URL When the restart process is finished please check whether iSearch the page of firmware update system information and the firmware version of status page have been updated yet 26 IStars Current Location Assistant Function gt Firmware Update Firmware Update Note To ensure the normal firmware update please upload correct update packa Update File UserName Name Time of Automatic Update Not a updated Manual Update Update ares a AA Note If the fir is reboot Figure 3 21 Page of Firmware Update Version This table displays the version of current firmware used by iStars Local Update Update firmware version by local uploading update package FTP Update Update firmware version by FTP FTP server The IP address of FTP Server is as the same as the IP address of User works tation FTP server must be switched on and set the path of upgraded version User name set username of FTP server Password set passwords of FTP serve Automatic updates time used to set the automatic update mode lt ca
17. rol e OOOO o mmm a o o wmo 2 Co emavsee O O UPS to Standby 60 Minutes e UPS Wake up from Standby State O Restart the UPS Apply Figure 3 7 Page of Remote Control UPS Self test UPS test in different condition or cancel UPS test The setting minutes should be integer between 0 and 99 Other ltems Four functions UPS shutdown UPS transfers to standby mode for setting time wakeup UPS from standby mode restart UPS are configurable The time of standby can be setting between 0 and 9999 integer minutes IStars 2 2 2 UPS Settings This webpage is used to set related parameters of UPS and there are four table options UPS Parameters UPS Records UPS self test and Alarming Settings According to the different protocols this webpage is also a slight difference Figure 3 8 is the page of Stars Individual Agreement Current Location Setting and Control gt UPS Setting UPS Setting Used to calculate the Enable Battery Management Battery Setting UPS Failed to Communicate Over Time 30 Seconds v a Apply Figure 3 8 Page of UPS Setting UPS Communication Protocol UPS communication protocol selection including EA EA three Emerson NXL Emerson UL33 Eaton Powerware Eaton XCP KSTAR MGE Galaxy 3000 MGE Galaxy 7000 KEHUA KEHUA three and so on AN The protocol parameters of different manufacturers may not be consistent such as Emerson NXL increased the bypass power alone configuration UL33 increased
18. tars CHAPTER2 INTRODUCTION Section1 Description of Hardware Figure2 1 Side View External Card Figure2 1 Side View Internal Card Figure2 3 Side View External Card NET port Ethernet 10M 100M LAN port GPRS port To GPRS module Y G R Led Light signal LED three color indicator light UPS port Serial port connect with UPS DC9V port To DC9V adapter Explanation of LED Light signal Light color definition Explanation Fault Light flash if UPS communication is break or there is other system fault Power supply Light on when system operate normally State of Light flash if communication is normal Light on means communication sending data Light off means receiving data IStars Section2 Disk Information Attached information of disk 1 Stars Operation Instruction 2 Search IP search software 3 SmartMate Shutdown software 4 4 SmartView Centralized management software IStars CHAPTER3 UPS WEB MANAGEMENT Section1 Introduction After finishing hardware connection and setting of iStars and network according to the IP address of Stars obtained by iSearch use the browser of any PC input IP address of iStars and then it can enter into the monitoring page of Stars to remotely monitor the UPS or set related information AN Make sure that the IP address is under the same net work segment with the host IP 1 Start the browser 2 Input IP address of iStars for example 192 168 6 6
19. ter or the computer cannot receive the notice Receive This function is used to set whether receive the trap notice SNMP Configuration Community String This set value must be the same as that of receive computer or the computer cannot receive the notice Te IStars 2 2 6 Email Settings This page determines whether transfer information to the destination Email address when Stars detects related event of UPS This page contains Email set Email address of receiver used to record the received event Email address of receiver used to receive the daily log and test set ng and Control gt Email Setting Apply Figure 3 13 Page of Email Setting Email Settings Email Server This address is used to set the server address of Email receiver set format Is website format such as www google com and it also can be written as IP address format such as 192 168 6 188 Email Ports Set of receiving port of Email Set format is integer Email Address Sender This address is used to set the Email address of sender Email Transmission is Encrypted Using SSL Option whether SSL encrypted transmit is used for Email Account Number 18 IStars Set Email account of sender which shall be the same as Email address of sender Password Set Email account password of sender Email Address of Recipient Receiving the Event Log Available Email Sent When the Event Occurs Warning It can set whether send the re