Short Manual - LI

image

Contents

1. System data Connection technology at input side MC 4 Jv Connection technology at output side spring loaded Z terminal strip Various Warranty Years 5 Warranty extension optional Years 10 20 Ext current sensor MBS ASRD 14 Rated current primary A 50 Precision method 1 Dimensions H x W x D mm in 90 x 105 x 54 8 5 x 4 1 x 2 1 Max cable diameter mm in 13 5 0 5 Mounting on top hat rail to DIN EN 60715 JS It is important that the maximum current load of the DC connector will not be exceeded in a parallel circuit max 30 A This could lead to damage of the device If the DC string input current is higher than the maximum current load of the plug see manufacturer s instructions both DC inputs must be used SOLAR ELECTRIC Service Hotline Germany and other countries France Belgium Luxembourg KOSTAL 49 761 47 74 42 22 33 1 6138 4117 Greece 30 2310 477 555 Italy 39 011 97 82 420 Spain 34 961 824 927 Portugal 1Language German English 2 Language Spanish English Smart connections 10117939 09 2014 edition subject to technical changes and printing errors
2. This manual is subject to technical changes and printing errors You can find current information on Tec h n al d ata P KO 9 E 0 s 8 3 our website www kostal solar electric com PIKO Inverter Unit 3 0 4 2 5 5 7 0 8 3 Input side DC Inverter type PIKO PIKO PIKO PIKO PIKO Max PV power kWp 4 3 4 6 6 1 7 7 8 9 MPP range with rated DC power sym V 270 730 400 800 265 800 330 800 230 800 String 1 MPP range with rated DC power unsym 400 800 265 800 330 800 ae s d 250 800 max 10A Max input voltage Usoma V 900 1000 1000 1000 1000 Min input voltage V 160 160 160 160 160 Rated input current A 12 6 33 8 3 10 56 12 5 Max input current Lc A 12 5 11 11 en oe Max input current with parallel connection A _ _ 22 22 36 DC1 DC2 Number of DC inputs 1 1 2 2 2 Number of independent MPP trackers 1 1 2 2 2 Output side AC Rated output cos 1 kW 3 4 2 5 5 7 0 8 3 Max output apparent power cos kVA 3 4 2 5 5 7 0 8 3 Rated output current A 13 6 1 8 0 10 2 12 Max output current loma A 13 7 6 1 8 0 10 2 13 3 39 PIKO Inverter Unit 3 0 4 2 5 5 7 0 8 3 Output side AC Short circuit current peak A 26 4 16 9 9 5 6 7 12 5 8 8 15 8 11 2 23 1 16 5 Number of feed in phases 1 3 Grid connection 1 N PE AC 230V 3 N PE AC 400V Rated frequency f Hz 50 50 Efficiencies Max efficiency 96 2 97 5 97 7 97 6 97 7 Max European efficiency rate 95 5 96 1 96 3 96 5 97 1 System data
3. The current can be used for the following m for consumption m for feeds into the public mains grid The unit may only be used in grid connected photovoltaic systems within the permissible power range and under the permissible environmental conditions The device is not intended for mobile use Inappropriate use can be hazardous and lead to injury or even death of the user or third parties Material damage to the device and other equipment can also occur The inverter may therefore only be used for its intended purpose Additional User Information For additional information please read the complete operation manual on the CD Exclusion of liability Any use that differs from or goes beyond the stated intended purpose is con sidered inappropriate The manufacturer accepts no liability for any damage resulting from this Modifications to the inverter are prohibited The inverter may only be used if safe to operate and in technically perfect condition Any instance of misuse will cause the termination of the warranty guarantee and general liability of the manufacturer Only a qualified electrician may open the device The inverter must be installed by an electrician who is responsible for observing the applicable standards and regulations Work that could affect the electrical power system of the respective utility company at the site of the solar energy feed in may only be carried out by qualified electricians expressly authorised li
4. Topology without galvanic separation 7 transformerless Internal protection according to IEC 60529 IP 55 Protective class according to IEC 62103 Overvoltage category according to IEC 60664 1 Input side PV generator Overvoltage category according to IEC 60664 1 Output side m grid connection Degree of contamination 3 Enviromental category outdoor installation JS Enviromental category interior installation JS 7 resistance 41 42 PIKO Inverter System data Minimum cable cross section of AC connecting line Minimum cable cross section of DC connecting line Max fusing on output side Tightening torque of PE connection outer Tightening torque of lid screws Operator protection Electronic disconnection device integrated Height Width Depth Weight Max air throughput Max noise emission Ambient temperature Max installation altitude Relative humidity condensing Connection technology at input side MC 4 Connection technology at output side spring loaded terminal strip Unit mm in mm in mm in kg lb m h dBA C F m above sea level 3 0 1 5 B16 C16 385 15 2 500 19 7 222 8 7 22 48 5 lt 33 4 2 B16 C16 385 15 2 500 19 7 236 9 29 24 52 91 43 5 5 7 0 1 5 1 5 4 B16 C16 B16 C16 3 5 RCCB type B according to EN 62109 2 385 15 2 385 15 2 500 19 7 500 19 7 236 9 29 236 9 29 25 5 56 22 26 5
5. Connecting AC and DC side LEBENSGEFAHR DURCH STROMSCHLAQ Wechselrichter spannungsfrei schalten RISK OF DEATH DUE TO ELECTRICAL SHOCK De energise the inverter DANGER DE MORT PAR LECTROCUTION Mettre onduleur hors tension PELIGRO DE MUERTE DEBIDO A ELECTROCUCI N Desconectar el inversor de la tensi n PERIGO DE MORTE DEVIDO A CHOQUE EL TRICO Desligar a tens o de corrente do inversor PERICOLO DI MORTE PER SCOSSA ELETTRICA Eliminare la tensione dall inverter LIVSFARE PGA ELEKTRISK ST D Vekselstr msomformeren skal kobles fra sp ndingen LEVENSGEVAAR DOOR ELEKTRISCHE SCHOK Schakel de omvormer spanningsvrij OHRO EN IVOTA ELEKTRICK M PROUDEM Odpojte st da od nap t PERICOL DE ELECTROCUTARE Scoateti ondulorul de sub tensiune SMRTNA NEVARNOST ZARADI ELEKTRI NEGA UDARA Razsmernik odklopite iz elektri ne napetosti NEBEZPE ENSTVO OHROZENIA IVOTA Z SAHOM ELEKTRICKEHO PRUDU Meni prepnite do beznap ovej prev dzky ELEKTRIK ARPMASI NEDENIYLE HAYATI TEHLIKE Invert r gerilimsiz hale getirin KINAYNOZ OANATOY AMO HAEKTPOMAHEIA tov To pg pa TOKOB LIVSFARA GRUND ELEKTRISK STOT Koppla v xelriktaren spanningsfri ZAGROZENIE ZYCIA PRZEZ PORAZENIE PRADEM Odtaczy falownik od zasilan
6. Version of parameter set Version of firmware Version of user interface Date of the last update Removable guarantee label Scope of delivery 4 2 20 4 2 20 amp 9 DON E SS C 5 aa 4 2 20 Selecting the installation side Protect from rain and water Protect from direct sunlight Select non flammable installation location Maintain safe distance from flammable materials or areas at risk of explosion Select vertical installation location Use the included wall bracket Ambient temperature must be between 20 C and 60 C Air humidity must be between 4 and 100 condensing LT N Select stable installation location No plasterboard or wooden walls Prevent access by children Required cooling space is 200 mm vertical and 100 mm horizontal Protect from dust contamination and ammonia Ensure easy access and visible display Ensure that people are not disturbed by operating noise Installation To lift the inverter Cooling space Mounting spaces To install several inverters SH Inverter Type Measures in mm inch gt lt PIKO 3 0 4 2 7 0 100 9 60 2 4 70 2 8 x 3 9 0 7 9 1 PIKO 8 3 12 100 3 9 200 7 9 66 2 6 35 1 4 PIKO 15 20 100 3 9 200 7 9 76 2 99 46 1 8 16
7. 18 unsym 20 10 36 DC1 DC2 10 10 This manual is subject to technical changes and printing errors You can find current information on our website www kostal solar electric com 12 PIKO 12 9 345 800 String 1 490 800 max 20A String 2 250 800 max 10A 18 1 sym 18 18 unsym 20 10 36 DC1 DC2 12 12 15 PIKO 16 9 260 800 String 182 325 800 max 20A String 3 250 800 max 10A 1000 160 22 74 sym 20 20 20 unsym 20 20 10 40 DC1 DC2 20 DC3 3 3 15 15 17 PIKO 19 2 290 800 String 182 375 800 max 20A String 3 250 800 max 10A 25 77 sym 20 20 20 unsym 20 20 10 40 DC1 DC2 20 DC3 3 3 17 17 20 PIKO 22 6 345 800 String 1 amp 2 450 800 max 20A String 3 250 800 max 20A 30 32 sym 20 20 20 unsym 20 20 20 40 DC1 DC2 20 DC3 3 3 20 20 47 48 PIKO Inverter Output side AC Rated output current Max output current homa Short circuit current peak Number of feed in phases Grid connection Rated frequency f Efficiencies Max efficiency Max European efficiency rate System data Topology without galvanic separation transformerless Internal protection according to IEC 60529 Protective class according to IEC 62103 Overvoltage category according to IEC 60664 1 Input side PV generator Overvoltage category according to IEC 60664 1 Output side grid connection De
8. 58 42 84 84 52 52 20 60 4 140 2000 100 8 3 2 5 B16 C16 445 17 5 580 22 8 248 9 8 37 5 82 7 2x48 42 43 44 PIKO Inverter Unit 3 0 Various Warranty Years Warranty extension optional Years Ext current sensor MBS ASRD 14 Rated current primary A _ Precision method _ Dimensions H x W x D mm in _ Max cable diameter mm in _ Mounting on top hat rail to DIN EN 60715 _ It is important that the maximum current load of the DC connector will not be ex ceeded in a parallel circuit max 30 A This could lead to damage of the device If the DC string input current is higher than the maximum current load of the plug see manufacturer s instructions both DC inputs must be used 4 2 5 5 7 0 8 3 10 20 50 1 90 x 105 x 54 8 5 x 4 1 x 2 1 13 5 0 5 7 45 46 Technical data PIKO 10 20 PIKO Inverter Input side DC Inverter type Max PV power MPP range with rated DC power sym MPP range with rated DC power unsym Max input voltage U Min input voltage U Rated input current Max input current ly Max input current with parallel connection Number of DC inputs Number of independent MPP trackers Output side AC Rated output cos 1 Pro Max output apparent power cos d Unit kwp kW kVA 10 PIKO 10 8 285 800 String 1 390 800 max 20A String 2 250 800 max 10A 15 1 sym 18
9. 6 79108 Freiburg i Br Germany hereby declares that the inverter PIKO 15 17 20 starting from FW 5 0 to which this declaration refers conforms to the following guidelines and standards European Standards including relevant amendments N 61000 3 2 2006 A1 2009 A2 2009 Harmonic currents N 61000 3 11 2000 Electromagnetic compatibility EMC Part 3 11 N 61000 3 12 2011 Electromagnetic compatibility EMC Part 3 12 N 61000 6 2 2005 AC 2005 Interference resistance for industrial environments N 61000 6 3 2007 A1 2011 Interference emission for domestic environments N 62109 1 2010 safety of power converters Part 1 N 62109 2 2011 safety of power converters Part 2 m m rm rm e m Directive 2004 108 EC Electromagnetic compalibility Directive 2006 95 EC Electrical Apparatus Low Voltage Directive Application of the CE marking in accordance with Appendix Ill Section B 2013 KOSTAL Solar Electric GmbH 2014 07 18 Werner Palm Managing Director Armin von Preetzmann Development Manager This declaration applies to all identical copies of this product This declaration loses its validity if the device is modified or incorrectly connected This declaration certifies compliance with the mentioned regulations but does not ensure the properties The safety instructions in the product documentation provided must be observed Proper use he PIKO Inverter converts DC current into AC current
10. censed by the utility company This includes changes to the factory preset parameters The installer must always observe the regulations of the utility company The utility company s specifications must always be observed when setting the parameters Type plate KOSTAL mm Solar Electric HanferstraRe 6 D 79108 Freiburg 49 0 761 47744 100 www kostal solar electric com BH XXXXXXXX Ha DCinput Umer XXX XXX V F3 Umax V lux 2 XXX A ACoutput 2 U LXXXXX VA 1 adj max XX X A HH XX YYY YW 1 E p coso 1 rotective Class 1 55 20 C 60 C OVC DC II 79 14 DIN V VDE V 0126 1 1 VDE AR N 4105 2 Art No NNNNNNNN HW XX XX A T ew xXx uxx EJ FEY Serviceupdate FI ES P XXXXXABCXXXXX of En Name and address of manufacturer Device type Item number MPP control range Maximum DC input voltage Maximum DC short circuit current Number of feed in phases Output voltage nominal Maximum AC power Maximum AC output current Deviating output with country setting Protective class to IEC 62103 Protection type and ambient temperature range Overvoltage category Requirements conforming to those of the built in grid monitoring Internal item number Serial number Version of hardware
11. ed must be observed EU Declaration of conformity The company KOSTAL Solar Electric GmbH HanferstraBe 6 79108 Freiburg i Br Germany hereby declares that the inverter PIKO 4 2 5 5 7 0 starting from FW 5 0 to which this declaration refers conforms to the following guidelines and standards European Standards including relevant amendments N 61000 3 2 2006 A1 2009 A2 2009 Harmonic currents N 61000 3 3 2013 Flicker N 61000 6 2 2005 AC 2005 Interference resistance for industrial environments N 61000 6 3 2007 A1 2011 Interference emission for domestic environments N 62109 1 2010 safety of power converters Part 1 N 62109 2 2011 safety of power converters Part 2 m m m rT m rm Directive 2004 108 EC Electromagnetic compatibility Directive 2006 95 EC Electrical Apparatus Low Voltage Directive Application of the CE marking in accordance with Appendix Section B 2013 KOSTAL Solar Electric GmbH 2014 09 30 Werner Palm Managing Director Armin von Preetzmann Development Manager This declaration applies to all identical copies of this product This declaration loses its validity if the device is modified or incorrectly connected This declaration certifies compliance with the mentioned regulations but does not ensure the properties The safety instructions in the product documentation provided must be observed EU Declaration of conformity The company KOSTAL Solar Electric G
12. eee KOSTAL IMAGE MAY DIFFER Smart connections Short Manual PIKO Inverter 3 0 20 EU Declaration of conformity The company KOSTAL Solar Electric GmbH HanferstraBe 6 79108 Freiburg i Br Germany hereby declares that the inverter PIKO 3 0 starting from FW 5 0 to which this declaration refers conforms to the following guidelines and standards European Standards including relevant amendments N 61000 3 2 2006 A1 2009 A2 2009 Harmonic currents N 61000 3 3 2008 Flicker N 61000 6 2 2005 AC 2005 Interference resistance for industrial environments N 61000 6 3 2007 A1 2011 Interference emission for domestic environments N 62109 1 2010 safety of power converters Part 1 N 62109 2 2011 safety of power converters Part 2 mr Im Directive 2004 108 EC Electromagnetic compalibility Directive 2006 95 EC Electrical Apparatus Low Voltage Directive Application of the CE marking in accordance with Appendix Ill Section B 2013 KOSTAL Solar Electric GmbH 2012 12 18 Werner Palm Managing Director Armin von Preetzmann Development Manager This declaration applies to all identical copies of this product This declaration loses its validity if the device is modified or incorrectly connected This declaration certifies compliance with the mentioned regulations but does not ensure the properties The safety instructions in the product documentation provid
13. gram Annual yield diagram Total yield diagram 33 Settings menu Basic settings Language Inverter name Date time Arc detection Hardware settings z String connection Current sensor Communication Network settings 1 Network settings 2 Router settings RS485 settings Portal configuration Event messages Device information SW HW version Serial number Country setting Function test S l gt n P TT Fan test L Service menu Service code L Factory settings Variations due to software versions UI level are possible 2 After entering the code additional menu items appear to configure the inverter The code can be obtained by electricians from our customer service 34 Select language Entering the name Set date Set time Parallel connection Mode Auto IP IP address Subnet mask External router Router IP Bus termination Bus bias voltage RS485 address Portal code Data export Immediately mailing On Off FW HW UI Serial number Country setting 35 Own consumption menu Own consumption Wh Own consumptions rate Autonomy degree Daily own consumption Total own consumption Own consumption Wh Own consumptions rate Autonomy degree Current build consump Battery W Solar generator W Grid W Phase sel Consumption Phase 1 W Phase 2 W Phase 3 W 36 37
14. gree of contamination Unit 10 14 6 16 2 25 16 7 97 7 97 1 12 17 4 19 3 27 4 16 7 97 7 97 1 15 21 7 24 2 42 28 5 3 S N PE AC 400 V 50 98 0 97 2 17 24 6 27 4 41 3 29 98 0 97 3 20 29 32 2 51 36 5 98 0 97 3 49 50 PIKO Inverter System data Enviromental category outdoor installation Enviromental category interior installation UV resistance Minimum cable cross section of AC connecting line Minimum cable cross section of DC connecting line Max fusing on output side Tightening torque of PE connection outer Tightening torque of lid screws Operator protection Electronic disconnection device integrated Height Width Depth Weight Max air throughput Max noise emission Ambient temperature Max installation altitude Relative humidity condensing Unit mm in mm in mm in kg Ib m h dBA C F m above sea level 10 B25 C25 445 17 5 580 22 8 248 9 8 37 5 82 7 2x48 43 12 B25 C25 445 17 5 580 22 8 248 9 8 37 5 82 7 2x48 44 15 17 6 6 4 B32 C32 B32 C32 3 5 RCCB type B according to EN 62109 2 7 540 21 26 540 21 26 700 27 56 700 27 56 265 10 43 265 10 43 48 5 106 92 48 5 106 92 2 84 2 84 56 56 20 60 4 140 2000 4 100 20 B40 C40 540 21 26 700 27 56 265 10 43 48 5 106 92 2x84 56 51 PIKO Inverter Unit 10 12 15
15. ia ELEKTRIL GI Lahutage vaheldi vooluv rgust PAVOJUS GYVYBEI D L ELEKTROS SROV S SM GIO Inverteriui nutraukite itampos tiekima ELEKTRISKAS STRAVAS TRIECIENA BRIESMAS Atsl gt invertoru no stravas OPASNOST PO ZIVOT OD STRUJNOG UDARA Isklju iti izmjenjiva OPASNOST PO IVOT ZBOG STRUJNOG UDARA Isklju iti izmjenjiva OPASNOST PO IVOT USLIJED STRUJNOG UDARA Izmjenjiva iskljucite sa naponskog napajanja OPASNOST PO ZIVOT USLED STRUJNOG UDARA Izmenjiva isklju ite sa naponskog napajanja Switch off DC side Switch off Safeguard Disconnect Wait 5 minutes AC side DC side SO AL Out Connecting AC and DC side Connecting AC side and current sensor Connecting DC side 20 _ DSL Modem AC LAN Sensor 21 Country specific installation Connecting main cable with sealing cap Second ground connection lis 0 D0000 3 Nm Option Connecting DC1 amp DC2 in parallel Data transfer communication board II DC1 DC2 DSL or LAN a 2 NEM NOTE For PIKO 3 0 and 4 2 the parallel connection is n
16. mbH HanferstraBe 6 79108 Freiburg i Br Germany hereby declares that the inverter PIKO 8 3 10 12 starting from FW 5 0 to which this declaration refers conforms to the following guidelines and standards European Standards including relevant amendments N 61000 3 2 2006 A1 2009 A2 2009 Harmonic currents N 61000 3 3 2008 Flicker N 61000 3 12 2005 Electromagnetic compatibility EMC Part 3 12 N 61000 6 2 2005 AC 2005 Interference resistance for industrial environments N 61000 6 3 2007 A1 2011 Interference emission for domestic environments N 62109 1 2010 safety of power converters Part 1 N 62109 2 2011 safety of power converters Part 2 m m rm rm mb dmn Directive 2004 108 EC Electromagnetic compatibility Directive 2006 95 EC Electrical Apparatus Low Voltage Directive Application of the CE marking in accordance with Appendix Ill Section B 2013 KOSTAL Solar Electric GmbH 2014 02 28 Werner Palm Managing Director Armin von Preetzmann Development Manager This declaration applies to all identical copies of this product This declaration loses its validity if the device is modified or incorrectly connected This declaration certifies compliance with the mentioned regulations but does not ensure the properties The safety instructions in the product documentation provided must be observed EU Declaration of conformity The company KOSTAL Solar Electric GmbH HanferstraBe
17. ot possible NOTE When using the parallel connection this feature must be acti vated under the menue Settings gt gt Hardware settings gt gt String connection Parallel connection 24 26 GSM modem el n n Tx B AO N d NOTE Before installing a modem read the user manual 27 Commissioning the inverter Installation Assistent Language AG Select language English 2 Enter 3 Enter Date time 4 Enter Select 5 Select string connection Language 6 D Enter English 7 Select modus of the Enter v current sensor 8 Enter Country setting 9 Select country Do you really want to apply 10 S Enter this country 11 Confirm Country settings No V with YES 12 Enter 32 Menu overview DC menu Settings menu Own consumption menu Depending the inverter software version of the communication board the menu may differ DC menu DC and AC AC menu DC input 1 DC input 2 U P DC input 3 Phase 1 U I P Phase 2 U I P Phase Total yield s Yield MWh Operation time h Grid parameters Limitation on Grid frequency Hz Cos Daily yield diagram Monthly yield dia