Home
User Manual - HURONIA ALARMS
Contents
1.
2. KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS IDS OPTIONS NAMES PRESS DISARM KEY DISPLAYSHOWS ENTER USER NO 1 ENTER USER NUMBER AND PRESS RETURN KEY DISPLAY SHOWS ENTER CODE _____ ENTER 1 2 3 4 AND PRESS RETURN KEY DISPLAY SHOWS ENTER USER NO X where X is one higher than the previous user number ENTER USER NUMBER AND PRESS RETURN KEY DISPLAY SHOWS ENTER CODE _____ ENTER 5 6 7 8 AND PRESS RETURN KEY DISPLAY SHOWS ENTER USER NO X Page 21 SETTING USER IDS Codes cont At this point you may continue to enter the codes for the rest of the users or you may PRESS NO KEY to exit from this option DISPLAY SHOWS QUIT PRESS YES KEY to exit to DISARM mode or PRESS NO KEY to return to the three option sub menu REMOVING USER IDS If a user code is no longer necessary you may remove that code from the system To do this choose the SETTING USER IDS option see page 21 ENTER USER NO AND PRESS RETURN KEY DISPLAY SHOWS ENTER CODE If the panel was installed prior to 1996 ENTER a single 0 zero AND PRESS THE RETURN KEY If the panel was installed after 1996 ENTER a single r PART ARM 2 AND PRESS THE RETURN KEY DISPLAY SHOWS ENTER USER NO X Exit as above Page 22 SETTING USER OPTIONS This option allows a Master user to assign operating options to each of the various users DISPLAY SHOWS IDS OPTIONS NAMES PRESS PART ARM 2 KEY DISPLAY SHOWS ENTER USE
3. THEN ENTER CODE _____ ENTER ANOTHER CODE AND PRESS RETURN DISPLAY BRIEFLY SHOWS NEW ID IS CHOICE X where X is choice 1 or choice 2 The system then returns to the DISARM mode DISPLAY SHOWS MM DD YY HH MM SS The new user code supercedes the old temporary code and the latter will no longer be valid Page 28 SYSTEM LOG This function allows authorized users the ability to either print or view the historical log ENTER USER CODE PRESS YES KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS SYSTEM LOG THEN PRINT LOG A yes or no answer is required PRESS YES KEY if a serial input printer has been connected to the panel the log contains the previous 300 or 600 historical events depending on the model of panel or PRESS NO KEY if no printer connected and the log will be sequentially displayed in reverse order most recent event first in 20 character bytes Note that date and time are now separated with two asterisks indicating that the panel is displaying the log Note also that you may fast forward through the log by repeatedly pressing the KEY or rewind the log by pressing the KEY To terminate either printing or displaying of the log PRESS NO KEY DISPLAY SHOWS ABORTED The system then returns to the DISARM mode DISPLAY SHOWS MM DD YY HH MM SS Page 29 BELL TEST This function is used to test the audible devices bells sirens etc ENTER USER CODE PRESS 5 KEY AND PRESS RE
4. PRESS YES KEY to exit to DISARM mode and DISPLAY SHOWS SHUNTED ZONES X alternating with MM DD YY HH MM SS When all zones are unshunted cleared or the panel is DISARMED DISPLAY SHOWS MM DD YY HH MM SS Page 13 BLOCK SHUNT CLEAR SHUNTS To clear a zone or block of shunted zones ENTER USER CODE PRESS SHIFT KEY NO KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS MEMORY SHUNT CLEAR PRESS HELP KEY under the word CLEAR DISPLAY SHOWS CLEAR FROM 1 ENTER NUMBER OF FIRST ZONE IN BLOCK to be cleared AND PRESS RETURN KEY 0 6 RETURN DISPLAY SHOWS CLEAR TO 6 THEN ENTER NUMBER OF LAST ZONE IN BLOCK to be cleared 9 12 RETURN If only zones 6 12 were previously shunted DISPLAY SHOWS QUIT Page 14 BLOCK SHUNT CLEAR SHUNTS cont If more than zones 6 12 were previously shunted DISPLAY SHOWS X SHUNTS where X is the remaining number of zones still shunted AND THEN QUIT PRESS NO KEY to return to the three option sub menu or PRESS YES KEY to exit to DISARM mode and DISPLAY SHOWS SHUNTED ZONES X if any zones remain shunted alternating with MM DD YY HH MM SS When all zones are unshunted cleared or the panel is DISARMED DISPLAY SHOWS MM DD YY HH MM SS Page 15 SET DATE TIME This function is used to change the date and time The entry must be in the military format MM DD YY HH MM SS ENTER USER CODE PRESS SHIFT KEY 9 KEY AND PRESS RETURN KEY if neces
5. zones may remain open Since the entry exit door is protected exit or entry through the door will cause the panel to beep In this mode if entry is made the beeper will sound and the system must be DISARMED or PART ARMED 2 again to avoid a full alarm If exit is desired but the premises will still be occupied the system must be PART ARMED 2 again prior to opening the door Note that the exit beeper will not sound but the usual exit time is available Similarly if exit is desired and the premises will be vacant the system must be FULL ARMED prior to opening the door ENTER USER CODE PRESS PART ARM 2 KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS PART ARM 2 If some PART ARM 2 zones are still open thereby preventing the arming the panel beeps and DISPLAY SHOWS CANNOT ARM followed by the OPEN zones 2 BACK DOOR or MENS ROOM WINDOW etc Page 4 FULL ARM FULL ARM mode is used when you are leaving the premises Close all zones Check that the display is showing Date and Time This means that there are no open zones and the panel may be armed Note Two special zones known as EXIT zones and FOLLOWER zones on the exit route may be open and will not prevent the FULL ARM mode from occurring ENTER USER CODE PRESS FULL ARM KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS FULL ARM If any zones other than EXIT or FOLLOWER zones are open when FULL ARM mode is chosen the system beeps and DISPLAY
6. 9 EUROPLEX TECHNOLOGIES CAN INC APLEX MIDIPLEX USER MANUAL FOR USE WITH SINGLE AREA SOFTWARE EUROPLEX TECHNOLOGIES CANADA INC C 1990 Revised November 2002 CONTENTS SPECIAL NOTE ABOUT USER CODES 1 DISARM 3 2 PART ARM 1 3 PARTARM 2 eS sami sdai ode 4 PULL ARM 525 tiii oe 5 ALARMS 34490 402555595345555359 645 7 ACKNOWLEDGE ALARMS 7 DOOR CHIME 8 e000525e608e4o4 9 SINGLE ZONE SHUNT 10 BLOCK SHUNT MEMORY 12 BLOCK 5 5 13 BLOCK SHUNT CLEAR SHUNTS 14 Sel DATEMIME 436259405454 16 DAYLIGHT SAVING TIME CHANGE 17 CLOSING WARNING 18 NEW CLOSING 19 SET TIME COMMANDS 20 SETTING USER IDS Codes 21 SETTING USER OPTIONS 23 SETTING USER NAMES 25 EDITING USER NAMES 27 OWN D sce ates aoe ares 28 SYSTEM LOG cecscavsedveceeasivesacess 29 BELL TEST 2214059669044 30 WARNING MESSAGES 31 INDEX deedaeeaniateheiseatesanseatas 32 A SPECIAL NOTE ABOUT USER CODES Each person authorized to operate the panel is given a us
7. CLOSING WARNING 18 CODES an rai e e A E a O ES 21 22 CORRECTING USER NAMES 27 Rech aR E A 16 DATEMIME n eee ie a 17 DAYLIGHT SAVING TIME CHANGE 17 DISARM ee ea he 2 DOOR CHIME aea ige yt paste a 8 EDITING USER 27 FAULTS 31 FULL ARM pect cipro 5 Fa ata Go 9 jie eaten 17 DSa 21 22 NAMES 25 26 NEW CLOSING 19 OPTIONS pei eas ae ean 23 24 PART aie we 3 PART ARM 22 4 REMOVING USER IDS Codes 22 SET DATE LIME E 16 SET TIME COMMANDS 20 SETTING USER IDS Codes 21 22 SETTING USER NAMES 25 26 SETTING USER OPTIONS 23 24 SINGLE ZONE SHUN tame 10 SLOW ENTRY ALARM 2 SYSTEM LOG go ee wae te ee 29 25 aceasta sete a lect yk Sela Ry 16 USER SET OWN ID 28 WARNING MESSAGES 31
8. R NO 1 ENTER USER NUMBER AND PRESS RETURN KEY DISPLAY SHOWS DISARM NO PRESS NO KEY if no and the selected user will not be allowed to disarm the system or PRESS YES KEY if yes and the DISPLAY SHOWS DISARM YES The selected user will now be allowed to disarm the system All options available to the Master user will be consecutively listed By pressing YES or NO you can allow or deny access to each item of the list for that selected user The display then increments to the next user Hint Whenever the display shows an option you may press the HELP key to jump to the next user Page 23 SETTING USER OPTIONS cont DISPLAY SHOWS ENTER USER NO X where X is one higher than the previous user number At this point you may continue to enter the options for the rest of the users or you may PRESS NO KEY to exit from this option DISPLAY SHOWS QUIT PRESS YES KEY to exit to DISARM mode or PRESS NO KEY to return to the three option sub menu Page 24 SETTING USER NAMES This option allows the Master user to record the names of the users This is useful when examining the log DISPLAY SHOWS IDS OPTIONS NAMES PRESS HELP KEY DISPLAY SHOWS ENTER USER NO 1 ENTER USER NUMBER AND PRESS RETURN KEY DISPLAY SHOWS The cursor will be flashing at the far left of the display The letters of the alphabet appear on the 19 keys and the cursor is used to select the required characters When the curso
9. SHOWS CANNOT ARM followed by a display of the OPEN zones When the system is successfully armed the exit buzzer will pulse for the duration of the exit time Exit the premises promptly When the buzzer no longer sounds the system is fully armed If by accident an alarm activation occurs during the arming procedure the bell siren may sound If this happens ENTER USER CODE PRESS DISARM KEY AND PRESS RETURN KEY if necessary Page 5 FULL ARM conid DISPLAY SHOWS DISARM THEN DATE amp TIME MM DD YY HH MM SS Details of the accidental alarm condition will then be flashed on the display e g INTRUDER ALARM WAREHOUSE AREA PIR Page 6 ALARMS If an ALARM or ALERT condition exists the display will flash the relevant messages e g INTRUDER ALARM 26 PERIMETER FENCE or ID SECURITY ALERT etc To clear all flashing messages from the display follow the ACKNOWLEDGE function below ACKNOWLEDGE ALARMS CLEAR DISPLAY This function is used to clear the display of flashing messages stop the beeper and in some systems silence the siren bells ENTER USER CODE PRESS 0 zero KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS CLEAR DISPLAY THEN INA MOMENT FINISHED and the system returns to the DISARM mode DISPLAY SHOWS MM DD YY HH MM SS Page 7 DOOR CHIME A door chime feature is available The system will beep for three seconds to announce the opening of an entry exit door The beeping
10. TURN KEY if necessary DISPLAY SHOWS USER TEST THEN MM DD YY HH MM SS The bells or sirens should now be sounding To silence the bells or sirens ENTER USER CODE PRESS DISARM KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS DISARM THEN MM DD YY HH MM SS Page 30 WARNING MESSAGES If any of the following messages appear silence the beeping tone by following the ACKNOWLEDGE function see page 7 The message below indicates that the AC power has been removed from the system DISPLAY SHOWS AC POWER FAIL The message below indicates that the standby battery is faulty or disconnected DISPLAY SHOWS BATTERY PROBLEM The message below indicates that a TAMPER condition exists on one of the zones DISPLAY SHOWS ZONE TAMPER ALARM The messages below indicate that a fault has been detected on the multiplex cable DISPLAY SHOWS LMTC DATA PROBLEM or LMTC CONTROL PROBLEM The message below indicates that a panel fuse has blown DISPLAY SHOWS FUSE 2 BLOWN Should any of the above messages be displayed CALL FOR SERVICE IMMEDIATELY Page 31 INDEX ACKNOWLEDGE ALARMS 7 ALARMS 7 BATTERY PROBLEM 31 ETE E 30 BLOCK SHUNT CLEAR SHUNTS 14 15 BLOCK SHUNT MEMORY 12 BLOCK SHUNT SHUNT 13 CLEARING ALARMS 5
11. W CLOSING TIME military time e g 21 00 DISPLAY SHOWS 21 00 1 NEW CLOSING PRESS RETURN KEY DISPLAY SHOWS BUSY RE SCHEDULING and the system returns to the DISARM mode DISPLAY SHOWS MM DD YY HH MM SS Page 19 SET TIME COMMANDS This function is used if the panel has been activated to permit a closing warning see page 18 It allows the user to program new closing times for the week ENTER USER CODE PRESS SHIFT KEY BACK SPACE KEY and if user code is less than four digits PRESS RETURN KEY DISPLAY SHOWS SET TIME COMMANDS THEN MAY SHOW 02 00 DAYLGHT SAVG PRESS RETURN KEY repeatedly until DISPLAY SHOWS 17 55 SUNDAY CLOSE ENTER NEW CLOSING TIME FOR SUNDAY military time AND PRESS RETURN KEY or PRESS RETURN KEY if the premises is closed on a Sunday In a similar manner examine those choices involving the message CLOSE When all entries have been examined the system automatically returns to the DISARM mode DISPLAY SHOWS MM DD YY HH MM SS Page 20 SETTING USER IDS Codes This function allows a Master user to assign unique ID codes to each of the various users Depending on the software version up to 36 99 or 250 users can be assigned In this section we shall assign to two users the codes 1234 and 5678 A four digit code is standard however the panel may be optioned at set up for a five digit code ENTER MASTER USER CODE DEFAULT 1 0 2 0 PRESS SHIFT KEY DISARM
12. de is 1000 and extends to 32767 Page 1 DISARM Disarm mode is used to turn the system off after entering the premises or to stop the bells sirens from sounding ENTER USER CODE PRESS DISARM KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS DISARM THEN DATE amp TIME MM DD YY HH MM SS If too much time is taken to DISARM the system then a full alarm will occur When the panel is finally DISARMED DISPLAY FLASHES SLOW ENTRY ALARM Zones which remain OPEN after disarming are displayed as NIGHT 16 OPEN or 16 RECEPTION PIR etc Page 2 PART ARM 1 PART ARM 1 mode is used to provide partial protection with the exception of the entry exit door while remaining in the premises Close all zones that are monitored when in PART ARM 1 mode Other zones may remain open Note that when the system is in PART ARM 1 mode the entry exit door is unprotected and may be used without causing an alarm ENTER USER CODE PRESS PART ARM 1 KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS PART ARM 1 If some PART ARM 1 zones are still open thereby preventing the arming the panel beeps and DISPLAY SHOWS CANNOT ARM followed by the OPEN zones 2 BACK DOOR or MENS ROOM WINDOW etc Page 3 PART ARM 2 PART ARM 2 mode is used to provide partial protection while remaining in the premises In Part Arm 2 mode the entry exit door is now in service Close all zones that are monitored when in PART ARM 2 mode Other
13. er code to identify him or her Throughout this booklet reference will be made to entering a user code and then selecting a function or an action INSTALLATIONS PRIOR TO 1996 If the panel was installed prior to 1996 and optioned for 4 digit user codes you may use a 1 digit to 4 digit code including leading zeros e g 009 or just 9 If the code has less than 4 digits you must press the RETURN key to complete the entry If the code has 4 digits it is not necessary to press the RETURN key The first valid code is 1 and extends up to 9999 If the panel was optioned for 5 digit user codes you may use a 1 digit to 4 digit code including leading zeros and again you must press the RETURN key to complete the entry If the code has 5 digits it is not necessary to press the RETURN key The first valid code is 1 and extends up to 32767 INSTALLATIONS AFTER 1996 If the panel was installed after 1996 and optioned for 4 digit user codes you must use a 4 digit code and leading zeros 0 0027 are not allowed The leading 0 has been reserved for DURESS alarm if so optioned It is therefore not necessary to press the RETURN key The first valid code is 1000 and extends up to 9999 If the panel was optioned for 5 digit user codes you may use a 4 digit code leading zeros are not allowed and you must press the RETURN key to complete the entry If the code has 5 digits it is not necessary to press the RETURN key The first valid co
14. ke RE ENTER USER CODE PRESS SHIFT KEY HELP KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS CANCEL HOUR CHANGE and then returns to DATE AND TIME This option has now been cancelled Page 17 CLOSING WARNING This feature is used to provide an audible warning that the closing time is approaching It is activated by the installer If this feature is in use and the system is not armed by the programmed warning time the buzzer beeps and DISPLAY FLASHES CLOSING TIME SOON The user now has a fixed amount of time closing delay to arm the panel see pages 3 5 or to enter a new closing time see page 19 If the system is not fully armed at the end of the closing delay the buzzer beeps and DISPLAY FLASHES PAST CLOSING TIME If your system is monitored by an alarm company you should telephone the company and tell them when you expect to close Alternatively they may telephone you and enquire as to when you will be closing If you choose to stay longer selecta NEW CLOSING TIME see page 19 for procedure DISPLAY SHOWS MM DD YY HH MM SS or you may FULLY ARM PANEL see page 5 and leave the premises Page 18 NEW CLOSING TIME This function is used in conjunction with the CLOSING WARNING option to allow the user to select a new closing time for the current day ENTER USER CODE PRESS 6 KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS NEW CLOSING TIME THEN 1 NEW CLOSING ENTER NE
15. r is pointing UP the character in the middle of the key may be selected PRESS SHIFT KEY once and the cursor will point to the LEFT PRESS SHIFT KEY again and the cursor will point to the RIGHT PRESS SHIFT KEY again and it will return to the UP position The direction of the cursor always indicates the character to be chosen To enter a space character PRESS RETURN KEY when the cursor is pointing to the left To save a name entry POSITION CURSOR UP AND PRESS RETURN KEY As an example we shall enter the name WENDY MILLER PRESS SHIFT SHIFT AND ENTER W You should now see a W and the cursor should be pointing to the right DISPLAY SHOWS w gt Page 25 SETTING USER NAMES cont PRESS SHIFT SHIFT AND ENTER E DISPLAY SHOWS WE lt ENTER N pD DISPLAY SHOWS WENDY lt PRESS RETURN KEY AND ENTER L L E R AND PRESS SHIFT SHIFT to return the cursor to the up position If a mistake is made see EDITING USER NAMES on page 27 DISPLAY SHOWS WENDY MILLERA PRESS RETURN KEY DISPLAY SHOWS ENTER USER NO X where X is one higher than the previous user number At this point you may continue to enter the names for the rest of the users or you may PRESS NO KEY to exit from this option DISPLAY SHOWS QUIT PRESS YES KEY to exit to DISARM mode or PRESS NO KEY to return to the three option sub menu Page 26 EDITING USER NAMES If you enter the wrong character s you can correc
16. remove individual shunts ENTER USER CODE PRESS NO KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS SHUNT ZONE 0 ENTER ZONE NUMBER to be shunted DISPLAY SHOWS r ZONE TYPE Notice that the zone type is preceded by an asterisk An asterisk preceding a zone means it is shunted To confirm your choice you may press the HELP key to display a description of the zone If the wrong zone has been chosen press the YES key to unshunt that zone Note that repeated pressing of the YES key turns the shunt symbol r and off To UNSHUNT a zone follow the SHUNT procedure above and when the display shows an r press the YES key to remove the shunt and notice that the disappears Should another zone have to be shunted unshunted PRESS DISARM key to increment the display to the Page 10 SINGLE ZONE SHUNT contd desired zone or PRESS PART ARM 1 key to decrement the display to the desired zone PRESS YES KEY to shunt the desired zone and again an asterisk will appear To exit from this routine PRESS RETURN KEY The system now exits and momentarily displays the total number of shunted zones DISPLAY SHOWS FINISHED THEN X SHUNTS The system then returns to the DISARM mode DISPLAY SHOWS SHUNTED ZONES X alternating with MM DD YY HH MM SS When all shunts are cleared or the system is DISARMED DISPLAY SHOWS MM DD YY HH MM SS Page 11 BLOCK SHUNT MEMORY This function is used to a
17. sary The current date and time is displayed with the flashing cursor over the first number of the date To change the date and time ENTER NEW NUMBER AND OR PRESS YES KEY to move the cursor to the right Continue in this manner To move the cursor to the left PRESS BACKSPACE KEY For example to change to March 19 1994 4 15 PM when DISPLAY SHOWS 03 01 90 10 55 21 ENTER 0 PRESS YES ENTER 1 9 PRESS YES ENTER 0 4 PRESS YES YES YES YES ENTER 1 6 PRESS YES ENTER 1 5 PRESS YES ENTER 0 0 AND PRESS RETURN KEY Note Military time is used If the date and time are not entered in the correct format INVALID ENTRY will be displayed when the RETURN key is pressed Re enter data as above DISPLAY SHOWS ENTER DAY NO 1 where Sun 1 Mon 2 Tue 3 Sat 7 CONFIRM ENTER DAY NUMBER PRESS RETURN KEY and the system returns to the DISARM mode DISPLAY SHOWS MM DD YY HH MM SS Page 16 DAYLIGHT SAVING TIME CHANGE Hour Change This function is used to prepare the panel to automatic ally adjust forward or backward for the daylight saving time change On any day of the week prior to the Sunday changeover ENTER USER CODE PRESS SHIFT KEY HELP KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS HOUR CHNGE ON SUNDAY On Sunday at 2 00 AM the panel will automatically add or subtract one hour and cancel the message If the hour change is entered by mista
18. t the error as follows PRESS SHIFT KEY until thecursor is pointing up DISPLAY SHOWS PRESS YES KEY to move the cursor forward right or PRESS BACKSPACE KEY to move the cursor backward left until it is flashing over the character to be deleted PRESS and hold the SHIFT KEY for about one second to delete the unwanted character from the display If you find that you are deleting more than you intended you are holding the SHIFT key down for too long You may find it easier to delete the entire name and start again ENTER CORRECT CHARACTER S see page 25 and notice that the text to the right of the cursor will move ahead PRESS SHIFT KEY IF NECESSARY to return cursor to the up position AND PRESS RETURN KEY Page 27 USER SET OWN ID 3016 and 3030E panels This function allows a general user to select their own code rather than use the code given by the Master user The general user now has an absolutely confi dential code The Master user must first authorize the use of this option and assign a temporary code to the general user This function can only be used once otherwise the Master user must reset the option ENTER USER CODE PRESS SHIFT KEY 0 zero KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS USER SET OWN ID THEN ENTER CODE The system requires you to enter two codes one of which it will choose for you to keep ENTER A CODE AND PRESS RETURN KEY DISPLAY SHOWS ENTER CHOICE 2
19. utomatically apply a pre programmed shunt to a block of zones When you choose MEMORY the panel will recall the previous pattern of shunted zones and re apply them This is useful if it desirable to shunt the same zones on a daily basis If no pattern exists choose BLOCK SHUNT SHUNT see page 13 to establish one ENTER USER CODE PRESS SHIFT KEY NO KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS MEMORY SHUNT CLEAR PRESS DISARM KEY under the word MEMORY DISPLAY SHOWS PRE PROGRAMMD SHUNT THEN X SHUNTS where X is the number of zones now shunted AND THEN QUIT PRESS NO KEY to return to the three option sub menu or PRESS YES KEY to exit to DISARM mode and DISPLAY SHOWS SHUNTED ZONES X alternating with MM DD YY HH MM SS When all zones are unshunted cleared or the panel is DISARMED DISPLAY SHOWS MM DD YY HH MM SS Page 12 BLOCK SHUNT SHUNT To shunt a zone or block range of zones ENTER USER CODE PRESS SHIFT KEY NO KEY AND PRESS RETURN KEY IF NECESSARY DISPLAY SHOWS MEMORY SHUNT CLEAR PRESS PART ARM 2 KEY under the word SHUNT DISPLAY SHOWS SHUNT FROM 1 ENTER NUMBER OF FIRST ZONE in block to be shunted AND PRESS RETURN KEY 9 6 RETURN DISPLAY SHOWS SHUNTTO 6 THEN ENTER NUMBER OF LAST ZONE IN BLOCK to be shunted AND PRESS RETURN KEY 9 12 RETURN DISPLAY SHOWS 7 SHUNTS THEN QUIT PRESS NO KEY to return to the three option sub menu or
20. will only occur when the door is opened and not if the door is left open or subsequently closed Note No user code is needed for this feature To activate this feature PRESS PART ARM 2 KEY TWICE within three seconds DISPLAY SHOWS DOOR CHIME ON alternating with MM DD YY HH MM SS To de activate this feature PRESS PART ARM 2 KEY TWICE within three seconds DISPLAY SHOWS MM DD YY HH MM SS Page 8 HELP This function is used to assist users who know their access code but have forgotten or are unsure of which function key to press ENTER USER CODE PRESS HELP KEY AND PRESS RETURN KEY if necessary DISPLAY SHOWS SELECT AN OPTION AND THEN THE FIRST OPTION ALLOWED TO THAT USER e g DISARM or FULL ARM etc The system is now asking for a yes or no answer That is does the user want to select the option displayed PRESS YES KEY if yes and the system will execute the option displayed or PRESS NO KEY if no and the system will display the next valid option available to that user You must answer yes to some option in order to exit from the HELP mode or if unsure wait 90 seconds for a time out Page 9 SINGLE ZONE SHUNT This function allows the user to place a zone out of service e g loading door window etc The panel will continuously display the total number of zones shunted Subsequent DISARMING of the panel will remove all shunts or re entry into this mode can selectively
Download Pdf Manuals
Related Search
Related Contents
"取扱説明書" Gigabyte GA-A55M-S2V Capitolato speciale di appalto "取扱説明書" HASBRO Downshift 80286 User's Manual THE DATA CENTER User Guide Reserve Gun Safe 2300166_01 CB FAM MOP BKT GB (1LG en) Copyright © All rights reserved.
Failed to retrieve file