Home

e2 studio 3.0.0.22 Release Note

image

Contents

1. In case of KPIT Renesas toolchain projects Whenever you add any include path in compiler assembler include path option it is not displayed in the Project Explorer gt prj name Includes 364 Application 301 Trace plugin Trace buffer full functionality needs addition New checkbox needs adding to the GUI e2 server gdb executable currently causes a security alert in Windows when executed for the first time The publisher is currently undefined also Accepting the dialog allows normal 220 GDB server operation to proceed 72 IO view plugin All IO registers for RX devices are listed as Read Write in the IO xml files used by the IO view even though some are read or write only 40 Application The message Error Unable to create variable object is sometimes shown during debugging when stepping out of functions There are some IO Registers where the same memory address holds 2 registers with difference access sizes These registers are general a read only register and another register used for writing which is write only These registers are currently all listed as R W in the IO Map file and so the view will attempt to display values for the wrote only registers When it does this the bytes are displayed 17 IO view plugin reversed
2. The right address is displayed in the Select Symbol dialog 4698 GDB However it is changed into the wrong value when shown in the Eventpoints view 4665 Profile plugin When a single address is specified as the filter for the profile plugin it does not work correctly The addresses matching the filter are not displayed in the view 4640 Application When a program is compiled by inter module optimization with the CCRX toolchain the disassembly view cannot always display the disassembly instructions mixed with source code 4634 Application The Log scale check box in the real time chart properties does not work Setting the box as checked and clicking OK will reset it to 0 When sub menu Add Watchpoint is performed from a Memory view it seems to have been registered correctly in the Breakpoints view even if there is an error condition 4607 Event points plugin An error occurs by Add Watchpoint when the maximum number of events was exceeded or when a ROM area is specified 4597 Application In some cases when a before PC eventpoint is set just after a break point the program execution will not stop at the address the eventpoint is located at All configuration changes are not saved on changing multiple configuration settings in one session for GCC tools Specifically this is referring to multiple settings changes across multiple configurations and the clicking
3. Label Expression or Keyword inside the section 2059 RX GCC build plugin When user clicks on add button when Label Keyword or expression is selected nothing gets added Source Disassembly not being displayed after trace view is opened 2044 Trace plugin Toggle off and on the Source Mode button and source is now displayed and view continues to behave correctly there on HEW Project Import fails to build file due to File or path name too long This is due to the difference between HEW and Eclipse In HEW object files are output to the configuration directory In Eclipse the files are output alongside the source file in the 2010 HEW Project Converter same directory 1982 RX GCC build plugin For Renesas CCRX the Converter phase gets invoked even when using the external linker subcommand option This should not happen This results in the following error message The selected hwp file overlaps the location of another project See attached dialog This is because when the project is removed from the project tree the Eclipse projects are not physically removed Deleting the Eclipse project files from the directory allows the operation to continue 1950 HEW Project Converter 1936 Coverage plugin When using the IECUBE for RL78 the source lines for coverage are not being highlighted correctly in some cases Trace Record execution address eventpoints are allowed with e2Studio these are not available with HEW should only allow Trace Record eventpoints of type data
4. 0 4295 Application The position of the eventpoint within the source window is wrong in case it is defined via an offset e g dummy_fkt_2 4 4304 Application Output file name cannot be changed in Build Artifact setting 4330 Application Memory renderings are now persisted when a debug session is terminated and the associated debug configuration is re launched When an error occurs after a program built it has to be manually removed otherwise this is kept in Problems even after multiple rebuilds The indexer picks up semantic errors in files OK and removes them when resolved Linker errors are not being cleared These need to be manually removed from the problems view 4332 Application after resolution 4346 Application Projects can now be created with multi byte characters such as those used in Japanese and Chinese character sets 4352 Application Errors and warnings are now colored in the build console window GNU RX vector table source file corrected The following change was made to ensure interrupt handlers work correctly 0xX0050 Reserved fp 0 0x0054 FCUERR fp INT_Excep_FCU_FCUERR 0x0058 Reserved fp 0 0x005C FRDYI fp INT_Excep_FCU_FRDYI 0x0060 Reserved fp 0 4361 Application 4362 IAR plugins For the IAR toolchain Although the Generate debug information is checked Settings gt IAR RX Assembler gt Output the debug option is not passed to the iasmrx 4369 Application Time stamp information added to the RX Tr
5. Application This can cause the debugger to hang SH2 70865A clicking step in when on the closing brace of a function will cause the server to run but never respond again 3410 GDB Server SH The only option is to terminate When debugging files with the same name show source addresses even though it may not be correct for the file in question The full file path is not considered just the filename and 3389 Application current debug context This can lead to e2 studio showing addresses unnecessarily The address of pointer type variable can not be modified in Expressions View e g typedef int PI Pls pi amp glb In this case address value of s pi can not be modified in Expressions View 3160 Application 3077 Application When using the RX Simulator The Failed to execute MI command error appears intermittently when stepping with RX simulator and showing local variables Real time refresh will not update visually for a complete structure 3054 Application The workaround is to monitor individual members of the structure When exporting a project that has external linked folders rather than files which are resident in a source directory they lose their directory structure in the exported archive When 3039 Application importing back into e2 studio the files specified as the original relative path are then not found This is a standard Eclipse issue and is the current specification 2948 GDB server Trace is not returning any records on first run from Pow
6. Bus mode on the trace view disable source mode on the trace view re enable source mode and then disable Bus mode Debug configuration button does not show last configuration The tooltip shows Debug RX630E but when the button is pressed 1801 Application RX62T is launched and RX62T is the one at the head of the list also 1790 Real time Watch Real time expression settings are not saved when the application exits When setting the Internal Flash Memory Overwrite debug option it is possible to exceed the maximum number of non continuous memory blocks supported No warning is given if this limit is exceeded 1778 Application When setting this option ensure the limit 16 for RX devices is not exceeded When the project has been selected to use SH The user is prompted to select the launch configuration on clicking run The launch configuration should be automatically selected 1742 Debug Configuration correctly For the SH7216 target and most likely other targets when using the address conditions and associated mask the boolean parameter parameter 17 address mask compare type is 1645 Event points plugin not being set to true Erase flash on start up option on RL78 should be executed once 1642 Application When e2studio connects successfully to RL78 target and erases the flash this option should return to false so that flashing is not done every time target is connected 1640 Application After creation a project cannot be deleted straight awa
7. access to make 1927 Event points plugin consistent with HEW 1904 Profile plugin Profile view Go to source throws an exception if no file path is defined in profiler When an RX hardware debug session is executing the reset button can be operated but does nothing 1891 Application In RL78 the debugger is reset correctly Due to file extension issue with s and S and due to known bug e2studio users wont be able to use s or S effectively to pre process assembly files that need GCC Hence we suggest renaming these files to use S gt asm 1889 Application S gt SIC Program execution stops inside a range when Range Exclusive is specified in the address settings for OA event points 1859 GDB server HEW Importer Compiler gt Warnings gt Advance gt Enable All check box is not mapped 1846 HEW Project Converter All warnings checkboxes are checked as expected however the Enable All option is not checked 1841 HEW Project Converter Importing HEW project generates warning in e2studio for src directory Import a HEW RX project in e2studio using the HEW project importer 1808 HEW Project Converter Check Project gt Properties gt Compiler gt Source gt Include file directories Paths are duplicated While source mode is enabled on the trace view if you swap or cycle to another view before returning to the trace view The contents of the view will be removed To obtain the source view again please follow these steps 1807 Trace plugin Enable
8. and GNURL78 v13 01 attempting to step into a C function call within an assembly file reset program asm results in a step over 2755 Event points plugin Timer Value for Performance Start Stop Eventpoints not being persisted 2930 GDB server It is not possible to power the RH850 board via the E1 debugger in the current release When debugging an IAR RX project you may get an error rebuilding your project while debugging As a workaround if you press reload before rebuilding your project will be re built 2963 GDB and the new binary reloaded into gdb after the build 3017 CDT The Show Opcodes feature within the Disassembly window does not work correctly This affects all targets 3059 Register plugin The Find feature of the registers view does not work When using trace and the RH850 debugger when using the Disassembly view and Instruction Stepping Mode a single step is performed 3061 Application Some additional commands relating to the debugger were included in the trace output Only the instruction add r15 r1 should only be displayed 3179 Application The setting of the Performance Analysis dialog is not saved 3207 CCRX Build plugin When using the Renesas C compiler CCRX C source files cannot be compiled as C files When using an external build system to build a project the Image Reload notification is not displayed when the image file is modified This reload notification is only launched for the 3331 Application internal build procedure 3450
9. apply 4579 RX GCC build plugin There is a problem in e2 studio that the cproject file can be modified even when the settings for the project were not changed This can be seen by entering the settings dialog and clicking apply directly after project creation In addition there are issues in generic Eclipse in this area 4550 Application For option comparison comparing the makefile is the easiest way to ensure the project settings are identical When debugging with RX there are problems with setting breakpoints when the hardware breakpoint resources have been exhausted and the software breakpoint setting also fails In this case the breakpoint appears to be valid but the debugger will not stop 4548 Application This can often be seen when the option Program re writes internal Program ROM is set to yes As this means software breakpoints cannot be set 4538 Static Analysis plugin The static analysis plugin cannot jump to the source location of a specified static function When building projects with CCRX that are in deep directory structures it is possible to experience build issues e2 studio is unable to build projects which create command lines 4515 CCRX Build plugin greater than 8191 characters 4492 Application The Module View of e2 studio does not display any information when an executable which includes debug information was downloaded to the target 4450 Application Linker section settings of Renesas toolchain are not getting saved for multiple config
10. etc gt Providers tab and check the GNU Toolchain Built in Language Settings Shared checkbox After selecting the mentioned check box the far keyword support will be added to the 4491 RL78 GCC build plugin imported project 4504 Application In the Memory and Memory Browser views the contents of memory near an end address is not displayed correctly The iodefine h and iodefine ext h which generated as e2 studio RL78 GNU executable project have insufficient register definitions Missing definitions in iodefine h P7 PM7 FLARS FLWL MONSTAO ASIM Missing definitions in iodefine_ext h 4505 Project Generation PU7 PIM5 GDIDIS BPALO BECTL FLSEC 4509 Integration Server The e2 studio integration service has been updated to allow C applications to use it 4514 Application Conditional includes and compilation does not work correctly when local options are set on a source file When debugging with RX the state of a debugger can become unstable by execution of a wait instruction 4531 Application When a wait instruction is executed Remote failure reply E31 will be displayed on the console gdb and the debugger will be disconnected 4578 CCRX Build plugin When using the CCRX toolchain there is a build error when setting options on a single source file for Compiler gt CPU gt Fast Interrupt register 4582 Application The port added by a
11. project is rebuilt the project that includes it does not re link when it is also built 4462 CCRX Build plugin The scan dependency tool should not be passing WIN32 when scanning the embedded source code 4470 Application RX debugging the ID code cannot be written even if it is downloaded with Flash Write mode 4477 Application Projects with linked resources are not getting built after import using the HEW project import feature RL78 IO Access with multiple access widths read incorrectly Work around Within your debug session from the IO Registers view All Registers tab add the registers you want to monitor to the Selected Registers tab Do not add 1 byte width registers that belong to a 2 byte register add the 2 byte register only Save the selected registers locally to an xml file Disconnect the debug session On the Debug configurations dialog Debugger Debug Tool Settings set IO Use Default IO Filename to No In IO Filename select the file you saved above Apply and debug 4485 GDB server The 2 byte register values should now be shown correctly 4488 Application Real time Refresh of the registered expression does not become effective on the Expressions View Only Japanese language edition far is displayed as a syntax error in the editor when using GNU RL78 After importing the project created in v3 0 0 11 or previous versions user has to go to Project gt Properties gt C C General gt Pre processor Include Paths Macros
12. restricts the file types that can be used as input files For example assembler input files only supports the following src SRC 4312 Application Src When the project has a toolchain that does not match the path for the toolchain installed on the machine problems with build can occur Workaround is to delete the org eclipse cdt core prefs file from settings folder and then import the project 4303 RL78 GCC build plugin Alternatively you can modify the toolchain path from Properties gt C C Build gt Environment Modifying the toolchain path builds the project successfully 4300 Real time Watch Modifying the name of a variable in the Expressions window may cause a prompt asking if the new variable should be made real time aware even if the old one was not 4280 Integration Server The GetExpressionS function in the Integration Server will in some cases return an invalid string Workaround is to use the ReadMemory call to get the raw data It is not permitted to use the tool chain editor on the Settings pages to attempt a conversion from GCC to CCRX or CCRX to GCC This conversion is not permitted and may stop your 4213 RX GCC build plugin project working correctly When using Segger JLink with the Force Hardware Breakpoints debug option enabled adding more than the maximum amount of breakpoints for a device and then removing some 4191 GDB server RX can lead to none of the breakpoints firing Workaround is to add a single breakpoint back in to trigg
13. the Coverage View 4056 Coverage plugin The only way to clear the file coverage indicators is to right click in the middle gutter and select Clear Coverage Markers 3992 Application When importing projects from HEW into e2 studio when the files are read only build errors occur following import Ensure the files are writable Breakpoints cannot be unset within the editor when code is ifdef out 3950 Application These breakpoints will need to be removed from the breakpoints plugin When importing a HEW project if it contains folders with the same name at the same hierarchy then not all the files will import successfully ie WorkSpace WorkSpace Developments src embOS Uti MEASUREMENT c WorkSpace WorkSpace Developments src protocols util SerialUtil c 3945 Application 3932 Application If e2 studio is installed into the desktop folder or the workspace is within the My documents area on Japanese operating systems the object converter can fail to execute correctly By default the e2 studio editor character code is set to UTF 8 This means it is possible to enter characters that are then not supported by default by the CCRX toolchain CCRX default input is SUIS To enable UTF 8 for the toolchain you must first select C99 support 3928 CCRX Build plugin When the current configura
14. 0xAA on a line by itself all of the main code will be removed when Generate Code button is pressed The key issue is that the brace is on the same line as the comment When initially creating a debug only project the extension of the specified module is not added to the debug configuration dialog This means the file cannot be found when launched 5016 Project Generation Adding the extension back manually rectifies the problem Symptoms Project fails to build after import from HEW 2010 HEW Importer Conditions If a long filename or path is used and the HEW project importer is used the project may fail to build Workaround Move the original HEW project to a shallow directory structure i e C Workspace and import from there Also ensure that the HEW project is relocated before importing into e2 studio Debug configurations have been modified in e2 studio 2 x So although you can re use the workspace and projects from e2 studio 1 x when you open the debug launch configuration 2424 Application for the first time it is updated Before doing this you should back up the launch file if you need to keep a 1 x version NA Application It is not possible to import e2 studio 1 x projects which are for the V850 device into e2 studio 2 0 Symptoms Project fails to build in first instance after ar
15. 10WLC R5F10WLD R5F10WLE R5F10WLF R5F10WLG R5F10WMA R5F10WMC R5F10WMD R5F10WME R5F10WMF R5F10WMG R5F110NE R5F110NF R5F110NG R5F110NH R5F110NJ R5F111NE R5F111NF R5F111NG R5F111NH R5F111NJ R5F110ME R5F110MF R5F110MG R5F110MH L1C R5F110MJ R5F110PE R5F110PF R5F110PG R5F110PH R5F110PJ R5F111ME R5F111MF R5F111MG R5F111MH R5F111MJ R5F111PE R5F111PF R5F111PG R5F111PH R5F111PJ 110 R5F51101 R5F51103 R5F51104 R5F51105 R5F5110H R5F5110J 111 R5F51111 R5F51113 R5F51114 R5F51115 R5F5111J 210 R5F52103 R5F52104 R5F52105 R5F52106 R5F52107 R5F52108 R5F5210A R5F5210B 21A R5F521A6 R5F521A7 R5F521A8 220 R5F52201 R5F52203 R5F52205 R5F52206 610 R5F56104 R5F56106 R5F56107 R5F56108 621 R5F56216 R5F56217 R5F56218 62G R5F562G7 R5F562GA RX 62N R5F562N7 R5F562N8 62T R5F562T6 R5F562T7 R5F562TA 630 R5F56307 R5F56308 R5F5630A R5F5630B R5F5630D R5F5630E R5F56316 R5F56317 R5F56318 R5F5631A R5F5631B R5F5631D R5F5631E R5F5631F R5F5631G R5F5631J R5F5631K R5F5631M R5F5631N R5F5631P R5F5631W 631 R5F5631Y R5S56310 R5F5631MF R5F5631PF Debug Support Only 63N R5F563NA R5F563NB R5F563ND R5F563NE R5F563NF R5F563NK R5F563NW R5F563NY 63T R5F563T4 R5F563T5 R5F563T6 R5F563TB R5F563TC R5F563TE R5F563TB 5V R5F563TC 5V R5F563TE 5V Debug Support Only 64M R5F564MF R5F564MG R5F564MJ R5F564ML RZ RZ A R7S72100 R7S72101 R7S72102 SH2A ISH7201 SH7203 SH72165AD SH72546RFCC SH7261 1 SH72620 SH72630 SH72640 SH72690 SH7670 SH2 ISH7047F SH70834A SH70844A SH70854A SH70865A SH71242 SH71252 SH7144F SH7145F SH7
16. 1464A SH71491R SH7615 SH7616 SH7618 SH7619 SH2a No FPU SH7206 SH7211 SH7243 SH7285 SH7286 SH Other ICUSTOM_DEVICE_1 SH 2A_C_1C3A_3 SH 2A_C_1C3A_4 SH 2A_C_1C3A_5 SH 2A_C_1C3A 6 SH 2A_C_1C3A_F SH CUSTOM MCU SH2A CUSTOM MCUI ISH2A CUSTOM SOC 1 SH2A CUSTOM SOC 2 SH2A CUSTOM SOC 3 SH2A CUSTOM SOC 4 SH2A CUSTOM SOC 5 SH70835A SH70835R SH70845A SH70845R SH70855A SH70855R SH70865R SH71243 H71253 SH71464R SH71494A SH71494R SH7214 SH72145AD SH72145BD SH72146AD SH72146BD SH72147AD SH72147BD SH7215 SH72165BD SH72166AD SH72166BD SH72167AD SH72167AD Option SH72167BD SH72265 8H72266 SH72267 8H72275 SH72276 8H72277 SH72314L 8H72315A 8H72315L SH72374A SH72374B SH72375B SH72394A SH72394B SH72395A SH72395B SH72531 SH72531FCC SH72531 RFCC SH72533 SH72533FCC SH72543R SH72544R SH72546R SH72612 SH7261_FPULess SH72621 SH72622 SH72623 SH72624 SH72625 SH72626 SH72627 SH72631 SH72632 SH72633 SH72641 SH72642 SH72643 SH72644 H72645 SH72646 SH72647 SH72660 SH72661 SH72662 SH72663 SH72670 SH72671 SH72672 SH72673 H72680 SH72681 SH72691 SH7606 SH7618A SH7671 SH7672 SH7673 Debug Support Only Integrated Code Generator Supported Devices CPU Family Devices RL78 G10 R5F10Y14 R5F10Y16 G12 R5F10266 R5F10267 R5F10268 R5F10269 R5F1026A R5F10277 R5F10278 R5F10279 R5F1027A R5F102A7 R5F102A8 R5F 102A9 R5F102AA R5F10366 R5F10367 R5F10368 R5F10369 R5F1036A R5F10377 R5F10378 R5F10379 R5F1037A R5F103A7 R5F103A8
17. 89 Trace plugin user 785 Trace plugin Bus mode records sometimes fail to update if rapid cycling through the available trace modes Using Find on Address allows the entry of a case insensitive hex number However on Destination Address a case sensitive string is required This needs to be made clearer on the 722 Trace plugin Ul When instruction stepping into code PC is sometimes not correctly placed 628 Application When this happens the home button does not restore the PC location correctly Clicking the current stack frame in the Renesas debug view does remedy the issue 567 Real time Chart It is not possible to edit series name in the real time chart view When entering address compare and mask values for an eventpoint hex digits are assumed The dialog should assume field values are decimal unless prefixed by a modifier such as 549 Application Ox for hex This is for consistency with data entry and presentation throughout Eclipse CDT When the refresh interval is 120 msecs the Real time views are not updating First observed in Real time Expressions but will probably affect Chart and Memory too 540 GDB server Increasing the refresh interval to 200 msecs is a workaround 525 GDB server When Move to Line is used with RX targets the program is resumed from the selected line the expected behaviour is that the program would remain suspended Browse remaining disabled on Eventpoints view Open the Eventpoints view Double click on the Event B
18. Application Select all and copying the registers to the clipboard does not work correctly This is also the case in the generic version of Eclipse Juno 3476 Application When finding registers in the IO view the result of the search is not highlighted but the view is scrolled 3662 Application The selection and copying of all variables to the clipboard does not work in e2 studio It also does not work in Eclipse Juno 3788 Application RL78 Stack pointer register cannot be changed from registers view 3832 Code Generator plugin Building an example using the code generator and selecting the Generate hardware setup in C caused the project to not build as the file iodefine h is missing 3841 Application When setting MBS gt Compiler gt Optimize gt Advanced option inter module for Optimization for access to external variables it causes a re build every time When modifying the PC on RL78 when leaving the register in the format OXFF lt main xx gt it fails 3860 GDB If you remove the lt main xx gt and just pass through a valid hex string it works fine 3909 CCRX Build plugin In case Inter module is specified in Compiler Optimize Advanced Optimization for access to external variables make exe process continues to run after build process is finished The GDB Python library is missing from the RH850 GDB executable 3960 Application As a work around the gdb library from gdb python lib within a GDB source drop can be placed in DebugComp Lib The prope
19. F110PG R5F110PH R5F110PJ R5F111ME R5F111MF R5F111MG R5F111MH R5F111MJ R 5F111PE R5F111PF R5F111PG R5F111PH R5F111PJ F12 R5F10968 R5F1096A R5F1096B R5F1096C R5F1096D R5F1096E R5F109AA R5F109AB R5F109AC R5F109AD R5F109AE R5F109BA R5F109BB R5F109BC R5F109BD R5F1 O9BE R5F109GA R5F109GB R5F109GC R5F109GD R5F109GE R5F109LA R5F109LB R5F109LC R5F109LD R5F109LE F14 R5F10PAD R5F10PAE R5F10PBD R5F10PBE R5F10PGD R5F10PGE R5F10PGF R5F10PGG R5F10PGH R5F10PGJ R5F10PLE R5F10PLF R5F10PLG R5F10PLH R5F10PLJ R5F10PME R5F10PMF R5F10PMG R5F10PMH R5F10PMJ R5F10PPE R5F10PPF R5F10PPG R5F10PPH R5F10PPJ F13 R5F10A6A R5F10A6C R5F10A6D R5F10A6E R5F10AAA R5F10AAC R5F10AAD R5F10AAE R5F10ABA R5F10ABC R5F10ABD R5F10ABE R5F10AGA R5F10AGC R5F10AGD R5FT10AGE R5F10AGF R5F10AGG R5F10ALC R5F10ALD R5F10ALE R5F10ALF R5F10ALG R5F10AME R5F10AMF R5F10AMG R5F10BAC R5F10BAD R5F10BAE R5F10BA F R5F10BAG R5F10BBC R5F10BBD R5F10BBE R5F10BBF R5F10BBG R5F10BGC R5F10BGD R5F10BGE R5F10BGF R5F10BGG R5F10BLC R5F10BLD R5F10BLE R5F10B LF R5F10BLG R5F10BME R5F10BMF R5F10BMG RX 111 R5F51111 R5F51113 R5F51114 R5F51115 R5F5111J RX 110 R5F51101 R5F51103 R5F51104 R5F51105 R5F5110H R5F5110J New features in 3 0 Component Description Application Previous version of e2 studio was based on the Juno Eclipse version This update moves the Eclipse version to Kepler SR1 Application CDT component update
20. G R5F101FH R5F101FJ R5F101FK R5F101FL R5F101GA R5F101GC R5F101GD R5F101GE R5F101GF R5F101GG R5F101GH R5F101GJ R5F101GK R5F101GL R5F101JC R5F101JD R5F101JE R5F101JF R5F101JG R5F101JH R5F101JJ R5F101JK R5F101JL R5F101LC R5F101LD R5F101LE R5F101LF R5F101LG R5F101LH R5F101LJ R5F101LK R5F101LL R5F101MF R5F101MG R5F101MH R5F101MJ R5F101MK R5F101ML R5F101PF R5F101PG R5F101PH R5F101PJ R5F101PK R5F101PL R5F101SH R5F101SJ R5F101SK R5F101SL R5F104AA R5F104AC R5F104AD R5F104AE R5F104AF R5F104AG R5F104BA R5F104BC R5F104BD R5F104BE R5F104BF R5F104BG R5F104CA R5F104CC R5F104CD R5F104CE R5F104CF R5F104CG R5F104EA R5F104EC R5F104ED R5F104EE R5F104EF R5F104EG R5F104EH R5F104FA R5F104FC R5F104FD G14 R5F104FE R5F104FF R5F104FG R5F104FH R5F104FJ R5F104GA R5F104GC R5F104GD R5F104GE R5F104GF R5F104GG R5F104GH R5F104GJ R5F104JC R5F104JD R5F104JE R5F104JF R5F104JG R5F104JH R5F104JJ R5F104LC R5F104LD R5F104LE R5F104LF R5F104LG R5F104LH R5F104LJ R5F104MF R5F104MG R5F104MH R5F104MJ R5F104PF R5F104PG R5F104PH R5F104PJ G1A R5F10E8A R5F10E8C R5F10E8D R5F10E8E R5F10EBA R5F10EBC R5F10EBD R5F10EBE R5F10EGA R5F10EGC R5F10EGD R5F10EGE R5F10ELC R5F10ELD R5F10ELE G1C R5F10JBC R5F10JGC R5F10KBC R5F10KGC G1E R5F10FLC R5F10FLD R5F10FLE R5F10FMC R5F10FMD R5F10FME HA R5F1076C R5F107AC R5F107AE R5F107BC R5F107DE HB R5F10MME R5F10MMG R5F10MPE R5F10MPG L12 R5F10RB8 R5F10RBA R5F10RBC R5F10RF8 R5F10RFA R5F10RFC R5F10RG8 R5F10RGA R5F10RGC R5F10RJ8 R5F10RJA R5F10RJC R5F10RLA R5F10RLC L13 R5F10WLA R5F
21. LE R5F101LF R5F101LG R5F101LH R5F101LJ R5F101LK R5F101LL R5F101MF R5F101MG R5F101MH R5F101MJ R5F101MK R5F101ML R5F101PF R5F101PG R5F101PH R5F101PJ R5F101PK R5F101PL R5F101SH R5F101SJ R5F101SK R5F101SL G14 R5F104AA R5F104AC R5F104AD R5F104AE R5F104AF R5F104AG R5F104BA R5F104BC R5F104BD R5F104BE R5F104BF R5F104BG R5F104CA R5F104CC R5F104CD R5 F104CE R5F104CF R5F104CG R5F104EA R5F104EC R5F104ED R5F104EE R5F104EF R5F104EG R5F104EH R5F104FA R5F104FC R5F104FD R5F104FE R5F104FF R5F10 4FG R5F104FH R5F104FJ R5F104GA R5F104GC R5F104GD R5F104GE R5F104GF R5F104GG R5F104GH R5F104GJ R5F104JC R5F104JD R5F104JE R5F104JF R5F104JG R5F104JH R5F104JJ R5F104LC R5F104LD R5F104LE R5F104LF R5F104LG R5F104LH R5F104LJ R5F104MF R5F104MG R5F104MH R5F104MJ R5F104PF R5F104PG R5F1 04PH R5F104PJ GIA R5F10E8A R5F10E8C R5F10E8D R5F10E8E R5F10EBA R5F10EBC R5F10EBD R5F10EBE R5F10EGA R5F10EGC R5F10EGD R5F10EGE R5F10ELC R5F10ELD RS5F10ELE G1C R5F10JBC R5F10JGC R5F10KBC R5F10KGC G1E R5F10FLC R5F10FLD R5F10FLE R5F10FMC R5F10FMD R5F10FME HA R5F1076C R5F107AC R5F107AE R5F107BC R5F107DE HB R5F10MME R5F10MMG R5F10MPE R5F10MPG L12 R5F10RB8 R5F10RBA R5F10RBC R5F10RF8 R5F10RFA R5F10RFC R5F10RG8 R5F10RGA R5F10RGC R5F10RJ8 R5F10RJA R5F10RJC R5F10RLA R5F10RLC L13 R5F10WLA R5F10WLC R5F10WLD R5F10WLE R5F10WLF R5F10WLG R5F10WMA R5F10WMC R5F10WMD R5F10WME R5F10WMF R5F10WMG L1C R5F110ME R5F110MF R5F110MG R5F110MH R5F110MJ R5F110PE R5F110PF R5
22. R5F103A9 R5F103AA G13 R5F1006A R5F1006C R5F1006D R5F1006E R5F1007A R5F1007C R5F1007D R5F1007E R5F1008A R5F1008C R5F 1008D R5F1008E R5F100AA R5F 100AC R5F 100AD R5F10 OAE R5F100AF R5F100AG R5F100BA R5F100BC R5F100BD R5F100BE R5F100BF R5F100BG R5F100CA R5F100CC R5F100CD R5F100CE R5F100CF R5F 100CG R5F100E A R5F100EC R5F100ED R5F100EE R5F100EF R5F100EG R5F100EH R5F100FA R5F100FC R5F100FD R5F100FE R5F100FF R5F100FG R5F100FH R5F100FJ R5F100FK R5 F100FL R5F100GA R5F100GC R5F100GD R5F100GE R5F100GF R5F100GG R5F 100GH R5F100GJ R5F100GK R5F100GL R5F100JC R5F100JD R5F 100JE R5F100JF R5F10 0JG R5F100JH R5F100JJ R5F100JK R5F100JL R5F100LC R5F100LD R5F100LE R5F100LF R5F100LG R5F100LH R5F100LJ R5F100LK R5F100LL R5F100MF R5F100MG R5 F100MH R5F100MJ R5F100MK R5F100ML R5F100PF R5F100PG R5F100PH R5F100PJ R5F100PK R5F100PL R5F100SH R5F100SJ R5F100SK R5F100SL R5F1016A R5F101 6C R5F1016D R5F1016E R5F1017A R5F1017C R5F1017D R5F1017E R5F1018A R5F1018C R5F1018D R5F1018E R5F101AA R5F101AC R5F101AD R5F101AE R5F101AF R5 F101AG R5F101BA R5F101BC R5F101BD R5F101BE R5F101BF R5F101BG R5F101CA R5F101CC R5F101CD R5F101CE R5F101CF R5F101CG R5F101EA R5F101EC R5F1 01ED R5F101EE R5F101EF R5F101EG R5F101EH R5F101FA R5F101FC R5F101FD R5F101FE R5F101FF R5F101FG R5F101FH R5F101FJ R5F101FK R5F101FL R5F101GA R5F101GC R5F101GD R5F101GE R5F101GF R5F101GG R5F101GH R5F101GJ R5F101GK R5F101GL R5F101JC R5F101JD R5F101JE R5F101JF R5F101JG R5F101JH R5F 101JJ R5F101JK R5F101JL R5F101LC R5F101LD R5F101
23. R5F10Y44 R5F10Y46 R5F10Y47 G12 R5F10266 R5F10267 R5F10268 R5F10269 R5F1026A R5F10277 R5F10278 R5F10279 R5F1027A R5F102A7 R5F102A8 R5F102A9 R5F102AA R5F10366 R5F10367 R5F10368 R5F10369 R5F1036A R5F10377 R5F10378 R5F10379 R5F1037A R5F103A7 R5F103A8 R5F103A9 R5F103AA R5F1006A R5F1006C R5F1006D R5F1006E R5F1007A R5F1007C R5F1007D R5F1007E R5F1008A R5F1008C R5F1008D R5F1008E R5F100AA R5F100AC R5F100AD R5F100AE R5F100AF R5F100AG R5F100BA R5F100BC R5F100BD R5F100BE R5F100BF R5F100BG R5F100CA R5F100CC R5F100CD R5F100CE R5F100CF R5F100CG R5F100EA R5F100EC R5F100ED R5F100EE R5F100EF R5F100EG R5F100EH R5F100FA R5F100FC R5F100FD R5F100FE R5F100FF R5F100FG R5F100FH R5F100FJ R5F100FK R5F100FL R5F100GA R5F100GC R5F100GD R5F100GE R5F100GF R5F100GG R5F100GH R5F100GJ R5F100GK R5F100GL R5F100JC R5F100JD R5F100JE R5F100JF R5F100JG R5F100JH R5F100JJ R5F100JK R5F100JL R5F100LC R5F100LD R5F100LE R5F100LF R5F100LG R5F100LH R5F100LJ R5F100LK R5F100LL R5F100MF R5F100MG R5F100MH R5F100MJ R5F100MK R5F100ML R5F100PF R5F100PG R5F100PH G13 R5F100PJ R5F100PK R5F100PL R5F100SH R5F100SJ R5F100SK R5F100SL R5F1016A R5F1016C R5F1016D R5F1016E R5F1017A R5F1017C R5F1017D R5F1017E R5F1018A R5F1018C R5F1018D R5F1018E R5F101AA R5F101AC R5F101AD R5F101AE R5F101AF R5F101AG R5F101BA R5F101BC R5F101BD R5F101BE R5F101BF R5F101BG R5F101CA R5F101CC R5F101CD R5F101CE R5F101CF R5F101CG R5F101EA R5F101EC R5F101ED R5F101EE R5F101EF RL78 R5F101EG R5F101EH R5F101FA R5F101FC R5F101FD R5F101FE R5F101FF R5F101F
24. ace output On e2studio v2 2 0 13 using GNURX v13 01 toolchain when removing unused and unreferenced functions variables with the gc sections linker option the rvectors interrupt vector section is deleted 4372 Application The KEEP option is now set by default to avoid this problem 4378 HEW Project Converter When importing some projects from HEW into e2 studio using the project import facility some source files were not included automatically 4395 Application A new page has been added to the build preferences to allow custom tools to be added to the build This is similar to the functionality offered by HEW custom phases Due to a mismatch between the user manual and the generated iodefine h some registers with smart manual cannot be searched and found 4399 Smart Manual plugin 4411 Application The rx converter exe can crash when a CCRX output file is converted that was created using the global optimization option 4413 Event points plugin Data access eventpoints are not persisted when e2 studio is closed and re opened 4430 Code Generator plugin For certain devices a Pin View has been added to the code generator to show pin settings visually It is now possible to change the device that the project is selected for after the project has been created This is especially useful for changing the memory usage view and also the smart manual 4459 Application Go to project properties gt gt C C Build gt gt Device 4460 CCRX Build plugin When a library
25. chive project import not from HEW 1922 Application Conditions If an archived project is imported it may fail to build the first time due to a residual d file Workaround Clean and Build a second time When using assembly code within a C source file Codan errors can be observed in the editor Even though the project builds successfully 2762 Application We do not have a workaround for this at this time Step into does not always work when using the CCRX 1 02 01 toolchain 2728 GDB To ensure this behaves correctly you will need to use CCRX 2 00 00 or greater as this issue with the debug information is corrected in this release If eventpoints do not always work just after they are set you can use the Apply to Target toolbar button in the Eventpoint view to send the Eventpoints to the target manually This will NA Eventpoints d i i always ensure the debugger target has all the required eventpoint updates before execution starts Fixed issues in 3 0 0 22 ID Component Description Wrench is not displayed after a file s build settings are modified 2278 Application This is a generic CDT issue If you delete a src folder and add it again with the same name it gets excluded from the build 2440 Application Click on the project and examine the source directories to add it back in 2504 CCRX Build plugin When source files have timestamps ahead of the current time the project will compile every time until the file dates are passed 2576 GDB Using RPBRL78L12
26. controls can become unresponsive 3797 Trace plugin Creating a new save file to save data will not display the job in the foreground Overwriting an existing trace file will show the progress dialog in the foreground 3795 Trace plugin Saving RX Simulator trace data to the disk can take some time due to the number of records obtained from the server Trace Start and Stop eventpoints not being sent down to target in time 3754 Application Making event point changes and then executing can result in them being missed the first time To avoid this you can use the Apply to Target toolbar button in the eventpoints window With 2 targets connected clicking between the two debug contexts in the Debug View will update the source addresses in the open Editor files 3663 Application However changing debug context does not seem to get detected if clicking on the top level of the debug context rather than on the lower level 3657 Application If e2 studio is installed into a directory where any segment of the file path contains a space then the memory map plugin information cannot be retrieved for any target 3626 Application Snapshot trace adding IO register eventpoints increases the data shown in the trace view but as they were removed there was no change in the data shown 3625 Application When using the Snapshot trace feature the data mask settings are not applied correctly 3585 Application The GDB server crashes when an E1 emulator is connected to a debug configuratio
27. d to 8 3 For an update on what is new in 8 3 of CDT please check this PP http wiki eclipse org CDT User NewIn83 Various updates made to the previous CDT integration to improve application functionality Project generation when using a folder that contains multi byte characters is now fixed When an error occurs in the linker and the user fixes it and rebuilds it is now removed from the problems tab Build console error and warnings are colour coded and you can also jump to the relevant source window when double clicked SUNS Oreos E neci i Application DH es Bate Elapsed build time is displayed in the build console The disassembly window now correctly shows Opcodes The included memory plugin with CDT has been enhanced The following improvements have been made When terminating the debugger the setup of the current renderings are stored in the current debugger configuration The memory renderings are automatically opened when the debugger connection is restored and the memory plugin is open Adding memory monitors with symbol support is improved e Monitor Memory Memory plugin Enter address or expression to monitor B Memory fill made more prominent Improved memory import performance from the memory plugin Waveform memory rendering added to memory plugin efile T Ras tene Char Trace Ci Memong C3 vmesl 92 ms 200 018 ave Form d Nen Rendenngs Memory plugin CODAN CODAN errors and warnings defaul
28. db 12 proc 42000 threadGroup i1 gdb 12 proc 42000 OSthread 1 thread 1 frame 0 is displayed 2671 GDB server Debugging can continue normally after this 2667 GDB When using a big endian target areas of memory not covered by the download module are considered little endian This causes problems when viewing disassembly and memory When importing a configuration from another project when building a File not found exception is shown when the user tries to import external linker file 2657 Application Creating the file inside the project directory should solve this issue 2651 Application Library Template Build fails when spaces are present for file or folder name 2636 Application Visiting build options and clicking on OK rebuilds already built GNUSH executable library c c project Set beyond this limit will return an error and the GUI displays a yellow warning triangle 2544 GDB However press resume F8 and no existing BP s work and cannot suspend just terminate For the G13 IEcube it supports one run break timer Currently e2 studio is setting the support to 3 2537 Performance Analysis 2486 Profile plugin Acquiring profile results can take a very long time following RX Simulator debugging Use of duplicate register is allowed for RXC project generation 1 Create RXC project 2 Go to RXC Global option page se
29. e than 64K of code relocation truncated linker errors may occur Add additional linker section should be added lowtext This section needs to contain the expression plt and have a fixed address of OxD8 The existing text section should be modified to follow on from this new section 4219 Project Generation RL78 L12 group of MCUs RL78 family The setting of Key interrupt flag and Detection edge may not be saved When saving the project after making the new setting and then reloading the project the setting reverts to the original setting as the new one had not been saved 4223 Code Generator plugin After reloading the project check that the setting of Key input interrupt is the same as the setting which was made before reloading RL78 G1A group of MCUs RL78 family The Conversion time mode of the Conversion time setting may not be saved When saving the project after making the new setting and then reloading the project the setting reverts to the original setting as the new one had not been saved 4224 Code Generator plugin After reloading the project check that the setting of Conversion time mode is the same as the setting which was made before reloading RL78 L13 group of MCUs RL78 family When the timer KB20 is in use the settings for Standalone mode period controlled by external trigger input and Interleave PFC power factor correction output mode may prevent the correct output of the API functions Make settings in Code Pr
30. e2 studio 3 0 0 22 Release Note 28th April 2014 Supported devices for project generation and debugging CPU Family Devices RH850 FAIL R7F701002xAFP R7F701010xAFP R7F701013xAFP R7F701018xAFP R7F701023xAFP R7F701025xAFP R7F701031xAFP R7F701035xAFP DIA R5F10CGB R5F10CGC R5F10CGD R5F10CLD R5F10CMD R5F10CME R5F10DGC R5F10DGD R5F10DGE R5F10DLD R5F10DLE R5F10DMD R5F10DME R5F10DMF R5F10DMG R5F10DMJ R5F10DPE R5F10DPF R5F10DPG R5F10DPJ R5F10TPJ F12 R5F10968 R5F1096A R5F1096B R5F1096C R5F1096D R5F1096E R5F109AA R5F109AB R5F109AC R5F109AD R5F109AE R5F109BA R5F109BB R5F109BC R5F109B R5F109BE R5F109GA R5F109GB R5F109GC R5F109GD R5F109GE R5F109LA R5F109LB R5F109LC R5F109LD R5F109LE R5F10A6A R5F10A6C R5F10A6D R5F10A6E R5F10AAA R5F10AAC R5F10AAD R5F10AAE R5F10ABA R5F10ABC R5F10ABD R5F10ABE R5F10AGA R5F10AGC F13 R5F10AGD R5F10AGE R5F10AGF R5F10AGG R5F10ALC R5F10ALD R5F10ALE R5F10ALF R5F10ALG R5F10AME R5F10AMF R5F10AMG R5F10BAC R5F10BAD R5F10BAE R5F10BAF R5F10BAG R5F10BBC R5F10BBD R5F10BBE R5F10BBF R5F10BBG R5F10BGC R5F10BGD R5F10BGE R5F10BGF R5F10BGG R5F10BLC R5F10BLD R5F10BLE R5F10BLF R5F10BLG R5F10BME R5F10BMF R5F10BMG F14 R5F10PAD R5F10PAE R5F10PBD R5F10PBE R5F10PGD R5F10PGE R5F10PGF R5F10PGG R5F10PGH R5F10PGJ R5F10PLE R5F10PLF R5F10PLG R5F10PLH R5F10PLJ R5F10PME R5F10PMF R5F10PMG R5F10PMH R5F10PMJ R5F10PPE R5F10PPF R5F10PPG R5F10PPH R5F10PPJ G10 R5F10Y17
31. ebugger features should be disabled 4869 Application The Memory view always opened on launch of a debug session It should not be re opened on launch if it has been closed in the previous debug session GDB considers PUSHC instruction to be part of the function prologue and it skips it Inserting a break point at function name instead of function name solves the problem tells GDB to start at the actual beginning of the function without skipping the prologue 4857 GDB 4833 Application The clean functionality executes every time irrespective of whether the object file is present or not 4826 CDT CDT global build console is empty after Build All 4825 Application Build selected file does not work correctly when the assembler source file is selected 4819 CCRX Build plugin Individual compile is not execute when Level2 is specified at the Perform inter module optimization 4813 HEW Project Converter The simultaneous build setting is not setup when the project is imported from HEW Please visit the C C Build preferences and select the Behaviour tab 4783 Performance Analysis The option to Reset timer before each run which is setup on the Performance Analysis dialog box is not reflected for RL78 The specification for RL78 is that the values are reset all of the time so the option has no meaning A symbol address is not changed correctly at registering an Event Point for Trace Start and Trace Stop eventpoints with RL78
32. er the reapply of all others 4189 Application It is not possible to build project which has more than 98 characters in its project name The Renesas CCRX toolchain fails to build projects with the following conditions a Project name with multi byte characters b Project located in a path with multi byte character 4176 CCRX Build plugin c Project contains file with multi byte character FPU option is not set correctly for GNURX RX200 RX100 executable project Disable generation of RX hardware FPU instructions option should be checked and grayed out for 4129 Project Generation RX200 and RX100 However this option is not checked and is not grayed out 4116 Profile plugin The loaded profile results in Profile View are shown on the right hand side even when the View Loaded Data menu item is NOT selected 4105 Application When using GCC on Japanese Windows If you create a new workspace on the desktop the default GCC projects fail to build correctly When the project is re named If the user then uses the feature project Build Configurations Build All The active configuration builds successfully but subsequent configurations 4104 Application fail After running a debug session with coverage on the whole file then a number of green indicators are displayed in the editor view as expected Close e2studio and restart The green indicators still remain even though there is no connection coverage is disabled and no coverage address ranges or file specified in
33. erON Reset to main with Segger J Link 2934 GDB server When using Performance Timer Eventpoints with RX Simulator eventpoints must be manually applied from the Eventpoints view before resuming 2910 GDB Registers do not display properly on SH2A 72691 2881 GDB Step over and step return do not work on SH2 70865 2859 IAR plugins When using IAR projects the SFR names e g PIOR1_bit no1 are not understood correctly in the editor 2762 Application When using assembly code within a C source file Codan errors can be observed in the editor Even though the project builds successfully 2739 Application le2studio editor typing profiles will be changed so that spaces are used instead of the Tab character to generate Renesas target device source code 2735 Trace plugin When using an IECUBE emulator saving large trace buffers can fail to complete 2716 GDB server RL78 Before PC events on IECube temporarily hard coded limit of 4 2696 Application RL78 cannot step over empty for loop HEW Importer output file P PP is not generated while building the project 2693 Application Workaround User will need to select Settings gt Compiler gt Object gt output file type gt Pre processed source file gt OK after importing the project and then build the project In e2studio for an application created by RL78 GNU compiler is the corresponding source code of RESET vector seem to be not found first and therefore a file with the info text No source available for g
34. eview so that the following API functions are output manually R_KB20_Create R KB20 Start R KB20 Stop R KB20 Set BatchOverwriteRequestOn R KB20 TKBOOn SmoothStartFunction Start R KB20 TKBOOn SmoothStartFunction Stop R KB20 TKBOOn DitheringFunction Start R KB20 TKBOOn DitheringFunction Stop R KB20 TKBOOn Forced Output Stop Functioni Start 4225 Code Generator plugin R KB20 TKBOOn Forced Output Stop Function1 Stop RL78 G10 group of MCUs RL78 family When generating code corresponding to the gcc compiler date information is outputted to the version comments box in the function header of the r cg reset program asm 4226 Code Generator plugin When workspace_loc FreeRTOS_ftpd_RSK_RX63N_rev100 src ANSI is specified in the include option it is not able to be expanded in project explorer 4246 Application WorkspaceDirPath macro works well RX111 group of MCUs RX family 4251 Code Generator plugin When Code Generator is added to RX111 project an extra node appears under Code Generator node at Project perspective tree Nothing is performed at the node When using CCRX 2 x there have been issues with differences in the Elf Dwarf output which needed to be resolved by the object converter in e2 studio 4265 CCRX Build plugin If you had an error such as warning Code section size 0x11B not a multiple of 4 this will now be resolved in 3
35. f you open the debug configuration dialog the lOView is populated with the correct target information Execution Address Eventpoints with trigger count do not work with Breakpoints on Segger RX Setting an execution address eventpoint with a trigger count on Segger JLink RX62N is not possible if any breakpoints exist including the default at main If an execution address eventpoint with a trigger count is set with a breakpoint both the eventpoint amp the breakpoint do not function Multiple breakpoints are set then only 1 does not 874 Event points plugin work Additional eventpoints function as normal 873 Debug Configuration No Renesas GDB hardware launch shortcut for IAR amp Green Hills plugins Launch shortcut needs manual creation 820 GDB server Address mask not working for RL78 Program execution does not stop expecting to see program execution stopping every time we access an address ending in e8 816 GDB server Data Access mask not working for address values for RL78 Program execution stops each time the address is accessed no matter what value it contains 811 GDB server Trigger Count not supported for RL78 but is still available in the Eventpoint View 803 GDB server RL78 program execution stopping on Equal when Not Equal is specified in the Compare Settings The trace plugin data field if find amp filter is set does not remember its value When reopened the data option has both fields populated with a numerical number not entered by the 7
36. ii custom bat B mieficinit arannana B Ponens a See hes ae s P Porcherell Henker ma cre eA a Code Generator x annaa nran ee P rannman sa af Device Top View A Device Lit View f Pipher functors d RX111 LQFP64 3 RSFS1115AxFM oramne nsn aaa ne ATH ES writable Satire Important workarounds useful to know when using 3 0 ID Component Description If you are experiencing slow building of projects within e2 studio there are some possibilities to improve The system environment will attempt to find the make exe tool via the system environment If you ensure the directory make resides in is at the start of the path variable it will find it NA Application more quickly Especially important if there are network drives in the path In the project properties C C Build tab behaviour tab you can switch on parallel build This will take advantage of the multi cores on your host machine if it has them In 2 1 or later this now defaults to on for new projects The GNU toolchain linker file format has changed in 3 0 This means projects that are developed in 3 0 and opened in 2 x will still continue to build However you may experience NA GCC Build Plugin issues visiting the GCC Linker Sections user interface Code Generator can delete user code between Start End comments in some situations Using the code generator if the following code is placed in the main function 5041 Code generator if data_in
37. ill need to manually resolve the error by specifying the header file path present physically on the file system Custom Tools does not work correctly when the Inter module is specified at the Optimization for access to external variables of compiler option 4900 Application In 2 2 the pre build commands were not executed as pre build but after the other phases were executed Now the pre build commands are executed before the build commences 4960 RX GCC build plugin some previous commands that assumed object files were available will now fail 4971 Application Build artifact modified in CCRX project is not persisted after conversion to GNURX The build artifact will need to be manually modified following the CCRX to GCC conversion 4973 Application Pre build and post build steps are not persisted after conversion from CCRX projects to GNURX projects Open issues in 3 0 0 22 ID Component Description Code Generator can delete user code between Start End comments in some situations Using the code generator if the following code is placed in the main function if data_in OxAA on a line by itself all of the main code will be removed when Generate Code button is pressed 5041 Code Generator plugin The key issue is that the brace is on the same line as the comment 5026 Application ICCRX to GNU RX Project conversion In Linker Section Section names contain sy
38. int for the process being debugged 1485 Application The edited address value in Memory window does not highlighted in red but does update 1460 Application Project builds but rx convertor exe fails when on network drive 1352 Application GNU Linker section Deleting section using delete button Keyboard does not work RX200 CPU selection should not be supported for toolchains lt 1 00 01 for the CCRX Renesas toolchain 1263 Application This toolchain does not support RX200 Build console arrows Next and previous does not work as expected 1065 Application On selecting Next arrow the listed errors are not scanned visited through 987 Application Exporting project if linker sections are modified and not saved generates an error Resource not synchronized is the message 935 GDB server RL78 G14 2 only allows one Event Break eventpoint 934 Event points plugin Eventpoints view toolbar label not updating for RL78 eventpoints 930 GDB server Unlimited number of Event Break eventpoints allowed on RL78 devices 909 Application Selecting Inhibit all warning messages does not disable advanced warnings 887 Trace plugin Trace address filter end range value gets set to the start range after reopening dialog 879 Trace plugin Find and filter are greyed out after closing trace view The only way to activate find and filter options is to resume debugging and suspend 877 Debug Configuration lOView is populated for the incorrect target for debug only projects I
39. ion GCC build can fail when there are resources with spaces in their name When using CCRX with MISRA warning messages Some problems are not shown correctly in the problems window The error messages are shown correctly in the CDT console window but they are corrupted in the problems window e g Instead of this format sre filename c 5 M0523028 Rule 2 2 Source code shall only use style comments 4781 Application Only the text style comments is displayed When using the IAR RX toolchain it is possible to see the following warning warning Loadable section ROM32 ro outside of ELF segments 4794 GDB This warning may affect the correct loading of the binary into memory Additional conversion is required to avoid this issue Project build fails for workspaces having special characters Such as or There are still limitations for certain characters in 3 0 In any of the below cases project build fails 1 If the filename contains 96 symbol e g test file c 4795 Application 2 If the workspace name contains A symbol e g workspace 4835 Application Projects that have linked resource files have these files imported as broken links while importing using the copy project into workspace option 4843 CCRX Build plugin When using the CCRX toolchain the scan dependencies tool is not passed the __RXV1 and RXV2 macros Linked resources do not get resolved on exporting the project as File system Archive File 4864 Application Users w
40. ion to e2 studio GCC projects Improved e2 studio integration service Add an include path to the build options of the toolchain in a project build configuration pair Add a library or archive file to the build options of the toolchain in a project build configuration pair e2 studio integration service Open a project that is currently closed in the workspace Set and clear standard Eclipse breakpoints at a source line or address Implement the ability to control debug execution more precisely using the step commands Events for resume and suspend of the debugger will be support to avoid the use of polling in the calling application Visual Expressions Additional controls added to the Visual Expressions plugin Including meter vertical slider horizontal slider and thermometer RX Debug Configuration RX Hot Plug support Improved code generator support for more devices along with Pin View support File ton Source Refactor Navigate Seach Project Run Window Help riz eead aai dg oues ACE E SE a EE E TE E PE Quik ecer LD Project Explorer 32 lB Porcherelio 33 E resst programie asia 7 asa mzin vad v as E e ae then Ee Sold ober wall gi ansvl 4 i PoncherelloIHrdarcDebug Prim Ee nce E a 3 volatile nt a E dosete lei interrupt handlers e IB lecetinen j Poncherello e Bi reat prog El sbike sbrkh R stackscth Code Generator li typedefineh quite TE vector table e HandnareBebug f
41. lect ROM gt R8 3 Select the same value for any other register e g RAM gt R8 it gives error message and prevents the user from project creation 2416 Project Generation 4 Now select R8 again for RAM register It doesn t show any error message and allows user to create the project 2390 RX GCC build plugin Exception is generated when all sections are removed from Linker UI It is possible for c and C files to be treated in the same manner in certain situations which is not correct 2299 RX GCC build plugin C extension is changed to c during project build 2193 GDB Server SH Reload of code for SH devices with external flash does not work Instead disconnect and reconnect Software breakpoints are not supported on targets that use external flash to run application Also in this case force Hardware Breakpoints In Debug tool settings set to No by default 2161 Application A warning message should be displayed while trying to set software breakpoints in such cases 2156 Application When using the profile window for SH72643 the execution time and average execution time shows negative values for the first time only after which it runs normally 2081 Application After building a project if user changes anything in linker subcommand file option only ObjCopy is gets invoked Linker should get invoked Linker Section Editor Need to conditional Enable Disable the UI buttons Add button is not disabled when user selects contents
42. mbol need to be removed manually When using the CCRX toolchain variables placed at address 0x0000 are displayed as no debug info in GDB and variable type is lost 5021 Application For variable type unsigned char section B 1 and unsigned short section B 2 When initially creating a debug only project the extension of the specified module is not added to the debug configuration dialog This means the file cannot be found when launched 5016 Application Adding the extension back manually rectifies the problem 5014 Application ICCRX to GNURX conversion Custom tool added in CCRX project is not available in the converted GNURX project 5004 Application ICCRX to GNU RX Convertor Local file options are not mapped for assembler files 4990 Application The open Renesas Tool Settings gt C C General click on Formatter option An exception is thrown 4988 Visual Expressions plugin The state of the Visual Expressions view is not saved when you press the X and close the view 4976 CCRX Build plugin When using the SHC compiler Selecting Absolute SYSROF in Linker Output Type of output file does not work correctly ar utility fails if the input is greater than 8191 characters The command line options are truncated after every 8192nd character 4975 RX GCC build plugin We will have to implement subcommand file using for ar utility similar to compiler and assembler Parallel build is not enabled after conversion from CCRX project to GNURX pr
43. n USB to serial converter is not displayed in the selection dialog in the RX debug configuration dialog 4602 CCRX Build plugin Scan dependencies tool uses __GNUC__ macro automatically when building with RXC toolchain It should only be used when using the GCC toolchains 4616 CCRX Build plugin The clean build operation can fail when there are many hundreds of object files to clean 4617 Application When the data of word size is written in a word size register a upper byte and a lower byte are reversed 4618 Application In the memory view when the data of word size is written in a word size register a upper byte and a lower byte are reversed 4620 Application In the memory view when a fill operation is performed for a memory range the last 1 byte is not filled When using CCRX 1 x and GCC toolchains when putting a breakpoint on an invalid line a dialog is displayed saying the breakpoint will be placed at the next available instruction A yellow warning icon appears in the original location and a new relocated breakpoint icon appears where GDB placed the breakpoint 4627 Application With CCRX 2 0 this does not happen 4629 Project Generation When a new CCRX project is created the section top address will be modified from 0x0 to 0x4 as the new default option 4694 Application User can not toggle method breakpoint then toggle line breakpoint at the line of an method name 4730 Application Pre build step gets invoked in between during project build 4772 Applicat
44. n configured for the Segger emulator 3550 Application Custom placeholders are not expanded when importing a project from HEW This is currently expected behaviour but may be improved in a future version 3526 Application In some cases when using RX with the CCRX compiler the profile view does not display the source file name and path in the window If a data type of a variable already displayed in the expressions view is updated e g from char to long after a re build the expression view data type is not updated However the data value is correct 3490 Real time Watch Closing the debugger or e2studio does not clear the issue but clean does When changing the PC value in the registers window the PC display is not modified in the e2 studio editor This is just a visual refresh issue Stepping causes the views to update and 3472 Application step occurs from the new location 3470 Application When debugging with the RX210 the FPSW register is displayed on the register view This should not be the case as the RX210 does not have the FPSW register 3447 Application Using the copy register functionality in the register window sometimes copies the incorrect register information to the clipboard 3430 Application Select all in the registers window does not work correctly It only selects the visible registers This is an issue in standard Eclipse Juno Execute The User Program After Ending The Debugger should not be enabled when the target is powered internally 3412
45. oject 4972 Application This can be switched on in the build configuration after conversion When source file is modified while debugging and the module rebuilt is downloaded via the module has changed dialog 4948 Application The module downloads correctly the target is reset but the e2 studio user interface does not show that PC has changed until a step is done A Exception occurred during launch message is displayed 4940 Application approximately 30 seconds after connecting to a target when using Hot Plug and using an image file In the Trace Acquisition dialog for the Renesas RX simulator 4939 Trace plugin The Trace Output field is not necessary it cannot be modified When debugging with RX if the project is built by CCRX V 1 02 an error is displayed when getting the coverage data If the project uses the CCRX V 2 01 toolchain the error is not 4906 Coverage plugin displayed Results in the coverage plugin do not relate to the actual program execution in some circumstances Lines show as not covered when assembly instructions were executed 4899 Coverage plugin When the code is optimized this situation gets worse 4892 Application When using GNU SH selecting file properties for s src file throws exception 4881 CCRX Build plugin When using CCRX if there are certain characters in the build path such as in the workspace name it can cause the build to fail 4876 Application When debugging with RX if the settings are in flash write mode the d
46. reak eventpoint category Select OR in the Trigger combo box Click Add on the Edit Trace dialog Click on the button alongside the Address text control 482 Event points plugin A dialog should appear with a list of address labels but the button remains disabled 480 Event points plugin Unable to add eventpoints using the insert key 478 Event points plugin Clicking on column headers in Eventpoints view does not order entries 475 GDB server RL78 Once a debug session has been terminated when using an IECUBE another connection is not possible until the IECUBE had been unplugged from the machine Trace view save and load trace data When trace data is saved the save dialog defaults to xml extension rather than rtt This means that the saved data is not loaded back into the view Also the load dialog defaults to xml but does not load the trace data back into the trace view regardless of the file type Illegal trace files are not flagged as non standard trace files as 452 Trace plugin per requirements When using the project generators some settings are not remembered correctly when moving forward in the wizard and then stepping back The CPU Type information is not saved while some of the additional options are remembered and some not 419 Project Generation In case of MinGW toolchain projects Whenever you add any include path in the compiler assembler include path option it is displayed in the Project Explorer gt prj name gt Includes
47. rties dialog for Image element in Visual Expressions view accepted a minus sign in edit fields which are Hex Octal and Binary number formats 4007 Visual Expressions plugin Also when using Hex Octal and Binary formats for number ranges the ranges will be converted using long data type rather than int data type When building with GCC if the compiler command line options string exceeds 8192 characters it is truncated and may not work correctly 4026 RX GCC build plugin If you encounter this issue please try using a shorter path for the root of the workspace you are building When using Real time Debugging a memory value is acquired per byte 4132 Real time Watch Therefore in some cases the wrong value will be displayed if two or more bytes of a variable are displayed in real time 4140 Application Performing a clean operation twice in succession for the CCRX toolchain performs a build and then a clean on the second clean operation 4150 Project Generation Working sample debugger support is removed after updating the product version To re enable the WS support please copy the files back into the product from the original archive When browsing for a toolchain in the add toolchain dialog in toolchain management if you use the context menu to paste the path into the dialog the add button is not enabled 4174 Application The workaround is to use shift insert or Ctrl v via the keyboard This will enable the button When building a GNU RL78 project with mor
48. sen SH ALR RH P Tread 1 200 Sigma TU 2 Col am de i Fo Rash ns lantane la retoron ied T EN UO MTor Co ont a g Dar i Ea EA O RATEN gt frena Sors Terence maai E Ren Festina Ghar Se Tee D FE 7 rac fania puta DH Sern Dire HPL SFO uri RU NKSEREREN 0 Debugger status Further modes added to the MCU display status control in the status bar Custom phases support similar to that seen in HEW Supported types in this version are Application 1 A custom tool e g yacc might be used to generate C C Asm source code for subsequent compilation by existing tools 2 A custom tool e g lint might be used immediately prior to building a C C Asm file to invoke an informational tool Real time chart Improved real time chart Builder Manual dependency scanning options added to the builder to improve overall build time when dependencies are known to be not changing CCRX Build plugin Renesas CCRX 2 01 00 toolchain support CCRX toolchain and global optimization option support Application Improved method of downloading and supplying smart manuals Improved installer capable of deploying Renesas plugins to a generic Eclipse Installer Requirements are as follows Eclipse base version needs to be Kepler The installer cannot use Helios or Juno Eclipse versions Application CCRX e2 studio project convers
49. tion is set to a custom configuration created by the user The configuration following an export and import into another workspace is not restored correctly 3867 Application It is restored to HardwareDebug 3847 Application When using the display as array feature in the expressions window it appears that data can be skipped and is not updated 3836 Application Dependencies with file name that have spaces may cause dependency scanning issues Where possible it is better to avoid using spaces in dependency file names 3822 Event points plugin Delete All is enabled in eventpoints window even when there is no eventpoints 3815 GDB server RL78 Trace Record Eventpoints not working for IECube 3813 Event points plugin OA event break event points not breaking at correct addresses on SH7203 External Flash target 3808 GDB server RX When using 2 RX simulator debug configurations in parallel the debugger does not work correctly Stepping and breaking does not work well The code generator is not automatically registered when installing into generic Eclipse Browse to the CG plugin and then run the batch files that reside in the tools directory e g 3804 Application iC Renesas e2_studio eclipse plugins com renesas cg_1 0 0 201309061659 CodeGenerator Tools Creating a new trace file for E20 trace data takes a long time to complete due obtaining disassembly data for all the available records 3798 Trace plugin During this period of obtaining disassembly data the debugger
50. ts have been reviewed and the levels changed accordingly to more accurately suit embedded software development HEW workspace import is now supported aime I Import HEW Project s HEW versions lower than v4 07 are not officially supported Only Compiler Assembler Linker and Library Generator phase settings will be imported Pre requisite Open project in HEW IDE Save the HEW Workspace File gt Save Workspace Import in e2 studio IDE Import S Application HEW Project HEW Workspace b Import HEW Workspace Select HEW workspace file hws CAwarkspace n 2n_Seqger n62n_ Seager Projects Project Name Target Selection Debug Hardware 4 CCRX RSESSLOTVAEP Gi n rx62n_Segger RsrSG10TVXEP El Bach N En Cancel RX RX64M is supported Improvements made to RH850 mE RH850 debugging also now supports the profile view The RH850 GDB now supports Python scripting correctly RL78 On chip trace now supported for RL78 F13 and F14 RL78 RL78 EZ Emulator supported Multiple download module support added ime Perche TE Mis 35 agger Be Bui Somes corner Ense nition Commands AENEA EUREN E Reset and Delay Geconds Load iage ard bol Application d aCe a a AN Bi west Desg E Funtime tons ElSe programi covers et T Set brestpointat al Ron Commands mcus Static Analysis Plugin EE T Green n P mesi sel M Da GDE Sit Pau
51. urations For GCC RL78 there is a option Select Additional CPU Options in the project generator with the following options None Use Emulation for multiplication Use RL78 native multiply for G14 Use RL78 hardware multiply for G13 However there are more device families which support the native or hardware multiply RL78 native multiply F13 F14 G14 RL78 hardware multiply D1A F12 G12 G13 G1E I1A L12 L13 Emulation for multiplication ONLY G10 4445 Application The user interface should be updated to better reflect the situation for the RL78 devices When debugging a project that has been imported but that has not been rebuilt you need to setup the debugger to look in the original source file location 4422 Application This is done via the Source tab of the Debug Configurations dialog 4397 Application If the linker files in a project are read only and the linker map is modified then no error is displayed or logged But the changes are not saved When importing a project from CubeSuite to e2 studio the toolchain version is changed dialog is always displayed This is because the version string in imported project file and the toolchain information in e2 studio does not match Ignoring this dialog and continuing should result in a successful 4350 Application import 4314 GDB Server SH For the SH debugger the Debug Tool Settings gt Use User Stack option is not processed by the debugger The setting is not used The current e2 studio build
52. y If the user waits around 30 seconds the project can then be deleted 1616 RX GCC build plugin The options of a Build Configuration were not correct after specifying Multiple Configurations functionality 1595 Application Renaming a project using the right click menu in the project explorer causes its respective debug configuration to disappear The edited value in Registers window was not highlighted when modifying the value in the registers window The edited value should be yellow highlighted 1532 Application Note This appears to work for the first edited register okay following a target suspend However any subsequent modifications are not highlighted The edited value in Expressions window is not highlighted The expressions are not updated in SR1 in the following circumstances 1 When editing in place within the expressions window 2 Modifying the value of the expressions in the memory window 3 When the target suspends and the views refresh 1531 Application In each of these cases any expressions with modified values should be highlighted in yellow 1523 HEW Project Converter HEW import page is displayed even when user tries to import normal project other than HEW project 1486 Application Breakpoint properties do not work when set in the CDT dialogs For example using the filter operation and removing the breakpo

Download Pdf Manuals

image

Related Search

Related Contents

  HC05P9 EMULATOR MODULE USER'S MANUAL PRELIMINARY  12 place dishwasher 5 prog [ddw 175]  AWP-81  ExStik DO600    必要な機能が、この一台に。  DYMO RHINO 4200 Kit  Hoja Tecnica Acidol  Manual del usuario Registrador/medidor de calidad de aire interior  

Copyright © All rights reserved.
Failed to retrieve file