INSTRUCTION MANUAL - Zeta Alarm Systems

image

Contents

1. 10 Issue 1 2 Author NRPJ Date 03 02 2014 FYREYE MKII ADDRESS PROGRAMMING TOOL Modification History Do Not Print This Page when creating PDF of the Manual ISSUE DATE CHANGES 1 0 10 9 2013 Initial Release 1 1 30 1 2014 Added Protocol select information Added Device compatibility chart 1 2 03 02 2014 Deleted STD protocol items from functions list Approved Document No GLT 252 7 1 PAGE 11 Issue 1 2 Author NRPJ Date 03 02 2014
2. 14 FYREYE MKII ADDRESS PROGRAMMING TOOL 2 Power Up Operation To turn on the programmer Press the two ON keys at the same time The display now shows following message After 3 seconds the following message will be displayed on the screen automatically Enter the password 447458 The Unit now displays Press ENTER to disable the password control on the next power up or press MENU to keep the password If the password has been disabled on the next power up the unit will display Press ENTER to enable the password control on the next power up or press MENU to keep the password disabled Approved Document No GLT 252 7 1 PAGE 3 Issue 1 2 Author NRPJ Date 03 02 2014 FYREYE MKII ADDRESS PROGRAMMING TOOL 3 Main menu Main Menu Screen 1 VY Indicates more functional setting menu Pressing W key shows more functional setting menu it indicates as below Main Menu Screen 2 B indicates the battery power It can indicate from B48 to B01 The B48 indicates the battery is fully charged and B01 indicates the battery power is low If BO1 is displayed the battery needs to be charged Approved Document No GLT 252 7 1 PAGE 4 Issue 1 2 Author NRPJ Date 03 02 2014 FYREYE MKII ADDRESS PROGRAMMING TOOL 4 Set Soft address Press Key 1 in Main Menu Screen 1 to select the function 1 Enable Soft address select the menu by pressing Key 1 Note make sure the Dip Switch A
3. FYREYE MKII ADDRESS PROGRAMMING TOOL FYREYE MKII ADDRESS PROGRAMMING TOOL A o INSTRUCTION MANUAL veta Approved Document No GLT 252 7 1 Issue 1 2 Author NRPJ Date 03 02 2014 FYREYE MKII ADDRESS PROGRAMMING TOOL Contents COM oso ooo i bono ate A A AS oo eae ooo o o o is 1 T B 0 n o fives 2d siecsress ceases aeiae aaa a Peunsatdocd apse oncea causteveanhds pba naat seek ote i iaraa Saia Ea aude sens teas vase cad i aaae Saa oE a oi aies 2 2 Power Up Operation ii A A iia 3 A ON 4 RR e A A A he a ee ee etd 5 AID Rea ta aa A a O 6 COMME en babu osa DVD avec pe Ode n oto non k Je 6 7 SET LED FLASH MODE cias AA AAA A epee enter BEOS ae AR 7 8 SELNEXT CAL DATE Soi a sdei canst tnegdetd enti besa dang sb a aa a aaa oi dicos orina ea a da pak a ra aaraa aiiis 7 9 SET GROUP ADORA aii 7 Supplementary instruction iia o iaa 8 10 Setting a ZAxx MI addressable interface from MKII Protocol to Standard Protocol cc cccscecsseessecsssesssecssecsseeesaeeseessesesseeeseeessaees 8 11 Setting a ZAxx MI addressable interface from Standard Protocol to MKII Protocol oooonccncccononcnococonnconnononocononono nono nonnnnnan nono nnnnnnnos 8 12 Setting the Address and LED Blink of a FEAOE2000 FEAOH2000 FEAHE2000 FEAHHE2000 sccsssessessessscseeessesseesessessesensenes 9 13 Electronic Specificatii Mea a EE A A A 9 WAS POWER SUVs ed e dd e ad O A e dad de de be 9 15 Summary of Functions available to ea
4. Type 0 Protocol It can be used to set addresses of Standard protocol ZAxx MI Interfaces or call points and can do command tests on those devices To return the programmer to MKII protocol disconnect any standard protocol devices and select Zeta II from the Select protocol menu described above 11 Setting a ZAxx MI addressable interface from Standard Protocol to MKII Protocol This is the same procedure as the MKII Standard Type 0 change Connect a Standard protocol ZAxx MI Interface Enter the hidden menu as described above Approved Document No GLT 252 7 1 PAGE 8 Issue 1 2 Author NRPJ Date 03 02 2014 FYREYE MKII ADDRESS PROGRAMMING TOOL Select option 1 to set to MKII Protocol After a short time the programmer will report MKII Selected NOTES 1 ONLY INTERFACES CAN HAVE THEIR PROTOCOL SELECTED VIA THE PROGRAMMING TOOL DETECTORS CALL POINTS amp SOUNDERS CAN NOT BE ALTERED BY THE PROGRAMMING TOOL 2 Currently the mains switching interface can not switch between protocols 12 Setting the Address and LED Blink of a FEAOE2000 FEAOH2000 FEAHE2000 FEAHHE2000 The Fyreye extra detectors also had the ability to be soft addressed but were never promoted with that facility They use a slightly different routine to other devices so have their own menu entry Go to the hidden menu amp select option 3 FEAXX2000 The programmer is now set up to soft address the Fyreye Extra Detectors 13 Electronic Specifica
5. ature will be implemented in the future to warn of heads reaching the end of their service life Press Key 5 in Function 2 screen to select the function 9 SET GROUP ADDR amp IDE Group addressing is normally performed by the control panel But this function could be used to set the group address of a replacement device instead of reconfiguring the loop If the group Address amp ID are known Press Key 6 in Function 2 screen to select the function Approved Document No GLT 252 7 1 PAGE 7 Issue 1 2 Author NRPJ Date 03 02 2014 FYREYE MKII ADDRESS PROGRAMMING TOOL Supplementary instructions The address programming tool is primarily intended for Setting the address of MKII devices But it also has the Following features 10 Setting a ZAxx MI addressable interface from MKII Protocol to Standard Protocol Power up the programmer as described in section 2 Scroll to the second menu page Type code 892130 ENTER The screen now shows Select Protocol IES ZB OE 0 3 FEAXX2000 OMV ONE OVA STU Type 0 is the standard OLD Protocol With a MKII interface connected to the programmer press 2 The programmer shows it s usual Please wait screen After a short while it will show Type O selected The interface has been programmed to type O Type0 Selected Menu to Return Press menu to continue If more devices are to be changed connect to the programmer and press 2 The Programmer is now also set for Standard
6. ch device ooooooccnoconocococncoonnconnnoncnonnncnnnnnnnncnannnnn nn cnn n non r ron nn nnn nn rr rra nn nro nn non r non nn RE RR RH nn HR n 10 Modification ISO rodea cia 11 Approved Document No GLT 252 7 1 PAGE 1 Issue 1 2 Author NRPJ Date 03 02 2014 FYREYE MKII ADDRESS PROGRAMMING TOOL 1 Description The Fyreye MKII Address Programming tool is primarily used to soft address Fyreye MK II addressable devices But it can also be used to set some operating parameters of the loop devices Detectors and the sandwich sounder simply clip onto the base to be programmed Other devices Such as interfaces call points 8 sounders are programmed with a cable plugged into the Loop Wire Output terminal The wires for LOOP output the white and black wire is positive the black wire is negative NOTE The BASE output will be disabled when LOOP Wire output cable is connected The Programming tool has 2 LED indications One to indicate that the unit is charging The other one indicates the status of the detector s remote LED output Battery Charge state indicator is displayed on the screen of hand held programmer Bxx in the bottom right corner The programmer will turn off automatically when the programmer is not operated for two minutes External RESET function this is located the backside of the hand held programmer 125mm 45mm 128mm Approved Document No GLT 252 7 1 PAGE 2 Issue 1 2 Author NRPJ Date 03 02 20
7. ddress is set to O before Soft address is enabled The range of the new Soft address is from 001 to 250 After typing the new soft address press ENTER The Soft address will be enabled and the Dip switch address will be disabled It shows as below 2 Disable Soft address select the menu by pressing Key 2 The address setting will be back to Dip Switch setting after Soft address is disabled 3 Set remote indicator address press Key 3 to select the function Only for Fyreye MKII The hand held programmer will read out the current Soft address list on the remote indicator at the beginning The current 10 addresses will be displayed on the screen Input the new soft address and press ENTER to confirm Approved Document No GLT 252 7 1 PAGE 5 Issue 1 2 Author NRPJ Date 03 02 2014 FYREYE MKII ADDRESS PROGRAMMING TOOL 5 Set Detector Type This function allows the device type of the detector to be altered EG setting an opto heat detector to heat only Note that selecting a sensor that is not present in the detector will result in the detector reporting a fault EG trying to set a heat detector to an optical detector The function is ideally used on an opto heat detector as it has all the components to be set to any type of detector Press Key 2 in Function 1 screen to select the function Only detectors can be changed to smoke type fixed heat type or opto heat type Press ENTER key to confirm and
8. press relevant number key to select the type 6 Command Test Press Key 3 in Function 1 screen to select the function In the state of command test the mode bits and command bits can be chosen by typing the number on the key pad Press Enter key to confirm Mode Command Operation i i R dat ae Bits o Detector Sounder Ancillary 0000 0001 Analogue state Input bits Remote LED Continuous tone Depends on 0000 0010 Analogue state Input bits Flasing LEDs Intermittent tone different devices 0000 0100 Analogue state Input bits Detector LED Flasher Alarm led 0000 1000 Analogue state Input bits Self test Emergency tone Test Approved Document No GLT 252 7 1 PAGE 6 Issue 1 2 Author NRPJ Date 03 02 2014 FYREYE MKII ADDRESS PROGRAMMING TOOL 7 SET LED FLASH MODE The alarm LED of detectors and call points can be programmed to flash when the device is polled Some panels EG the quatro panel allow an LED blink function to be set via the panel It is not advisable to set LED blink at the panel and at the device as this will make the LED blink more often and could cause confusion Press Key 4 in Function 2 screen to select the function Press relevant number key to select the function Press Key 1 to go into Enable Flash LED Press Key 2 to go into Disable Flash LED 8 SET NEXT CAL DATE No current Control panels support monitoring the calibration date but this fe
9. tion SLEEP CURRENT 0 81A STANDBY CURRENT 2 3mA SET DETECTOR CURRENT 6 8mA 14 Power supply 1 Rechargeable NI MH Battery pack The programmer can work 48 hours continuously when NI MH Battery power is full The charge indicator will be illuminated during battery charging The indicator will be turned off automatically when the battery is charged It takes 10712 hours to charge the battery from empty to full condition The NI MH Battery can be recharged 500 times The programmer can be operated during battery charging 2 External 12V adapter Approved Document No GLT 252 7 1 PAGE 9 Issue 1 2 Author NRPJ Date 03 02 2014 FYREYE MKII ADDRESS PROGRAMMING TOOL 15 Summary of Functions available to each device Device Photo Programmer Soft Address Programmer LED Programmer Protocol blink change DETECTORS MKII Axx Vay YES YES INTERFACES ZAI M YES ZAIO M ae ZAZM M y ZASC M EEO ZAIOI 230 SMM S SMM C SMM B CALL POINTS ZT CP3 AD es YES SOUNDERS MKII AMDx YES MKII AMTx jE YES MKII AXTx fw YES EN MKII SSB YES m 1D2 SFB YES REMOTE INDICATORS KDD MKII ARL C en YES YES YES Vy A A MKII ARL W cos YES YES YES 4 y Approved Document No GLT 252 7 1 PAGE