Home

AS316X6 Detailed User`s Manual

image

Contents

1. Modules All PSFMs are inserted into the rear of the chassis 1 5 1 PSFM Panel Power On Fail Indicator g Power On Off Switch M AC Inlet Plug Male s The Power Supply Fan Module panel has Power On Off Switch the AC Inlet Plug and a Power On Fail Indicator showing the Power Status LED indicating ready or fail Each fan within a PSFM is powered independently of the power supply within the same PSFM So if the power supply of a PSFM fails the fan associated with that PSFM will continue to operate and cool the enclosure User Manual og 1 5 2 Power Supply Module LED When the power cord connected from main power source is inserted to the AC Power Inlet the power status LED becomes RED When the switch of the PSFM is turned on the LED will turn GREEN When the Power On Fail LED is GREEN the PSFM is functioning normally 1 5 3 Fans of PSFM Each PSFM has 2 fans Master Fan and Slave Fan The Master Fan is located beside the PSFM panel The Slave Fan is located in the rear side Slave Fan Master Fan shown as MF PSU A and Slave Fan of Power Supply Unit A is _ 3 shown as SF PSU A Master Fan of Power Supply Unit B is MF PSU B and Slave Fan of Power Supply Unit B is SF PSU B s NOTE In the LCD display Master Fan of Power Supply Unit A is ITU User Manual 1 6 LCD Display Panel Model Name Chassis ID 0 1 6 1 LCD Panel LED Power LED Power Fail LED Fa
2. Two 4x mini SAS 6Gb s Two 4x mini SAS 6Gb s 6Gb s SAS 6Gb s SATA 6Gb s SAS SATA 16 Yes with Lock Indicator Access LED and Fail LED In Band SES via SAS 2 x 500W with PFC 2 Multi speed Yes Yes AC 90V 264V Full Range 9A 4 5A 47Hz 63Hz 10 85 Non condensing 10 C 40 C 50 F 104 F 590 L x 482 W x 131 H mm 24 Kg without drives User Manual 5 1 3 Unpacking the J BOD Expansion Chassis The package contains the following items JBOD Expansion Chassis Two power cords One serial cable phone jack to DB9 One external Mini SAS cable SFF 8088 to SFF 8088 e Installation Reference Guide e Spare screws etc If any of these items are missing or damaged please contact your dealer or vendor for assistance User Manual 1 4 Identifying Parts of the Expansion Chassis The illustrations below identify the various parts of the expansion chassis 1 4 1 Front View Drive Carriers LCD Display Panel Slot 4 Slot 3 Slot 2 Slog Slot 8 Siot7 Slot 6 Slot 5 Slot 12 Slot 14 Slot 16 Slot Slot 16 Slot45 Slot 14 Slot137 _ 1 4 2 Rear View PSU A Expansion Drawer PSU B Master Fan Master Fan User Manual ae 1 4 3 Expansion Drawer Link LED SAS INA Port SAS IN B Port gt Access LED e we gt E SAS Expansion A SAS Expansion B
3. AID card used in the Host Server the DI P switch must be set according to the tables below DIP Switch Setting SAS RAID Card Note 01110000 LSI Internal ports 18 User Manual Steps 1 Remove the Expansion Drawer from the enclosure 2 Configure the DIP Switch in the JBOD controller to the appropriate setting Note that 0 is ON and 1 is OFF Example settings LSI 3 Reinsert the Expansion Drawer into the enclosure User Manual 19 Chapter 3 JBOD Firmware Upgrade IMPORTANT Before upgrade the J BOD firmware please shut down server first or make sure no array setting on the J BOD disks The new Firmware will effective after JBOD power cycle Steps 1 Used RS 232 Port Phone jack to DB9 link ProSun SAS JBOD in command line please type system upgrade than press Enter f 39 HyperTerminalPort 2 HyperTerminal File Edit View Call Transfer Help cmd gt system upgrade Please Use XModem Protocol for File Transmission Use Q r q to quit Download before starting Modem SssssSSSS Connected 0 00 26 Auto detect 115200 8 N 1 SCROLL CAPS NUM Capture Print echo EET User Manual 2 Select Transfer amp Send File You must finish within 25 seconds HyperTerminalPort 2 HyperTerminal q I D x File Edit View Call Transfer Help Send File Receive File Capture Text Send Text File cmd g
4. IGITAL ACCUSTOR AS316X6 QUICK INSTALLATION GUIDE v1 0 Table of Contents Chapter 1 Introduc8ction 3 LE POO A PPP RA 4 12 ale a o A A A 5 13 Unpacking the JBOD Expansion Chassigu LLL LLL Enei e eie Ta A EAE EENAA tics 6 14 Identifying Parts of the Expansion Chassis ccccsssessssssecsssessesessesesessesessssescssssessesesessesessesecssecsseseesssesesseseeseees 7 fol PONE VW us sun iaa bola ret lactea 7 TAZ j POTS SSO 7 LAS Po P iD y uu ns sma ticos 8 15 Power Supply Fan Module PSFM int 9 Kad a 9 15 2 Power supply Module LED cocacola 10 LS PS Oracle 10 COPO Olay Ran sosa api 11 EL CO PAE ina libas 11 162 LCD Pamelirunction BUTTONS asalta 12 O Menu D O ee aca 13 LF Dive aier ModE eee nS Ot mer er Oe etn nr nT oe uu nT Pe 14 t71 Disk Drive Stat s IO COTOS nidad 14 172 Drive Carrer Lock Inicio 15 Chapter 2 Installation of Expansion Chassis 16 ZE TASTING Hara DIVE e E iicaios 16 2 2 Setting the DIP Switch of JBOD Controller io aia 18 Chapter 3 JBOD Firmware Upgradaes 20 OO A User Manual Chapter 1 Introduction Sans Digital AccuSTOR The AccuSTOR JBOD Enclosure is a 19 inch 3U 16 bays rackmount J BOD unit It feat
5. SU A Good PSU B Good FAN Status Good gt MF PSU A 3409 RPM SF PSU A 2616 RPM MF PSU B 3479 RPM SF PSU B 2596 RPM Voltage Status Good gt a gt 5V 5 23V 12V 12 33V Buzzer Status Disabled gt Disable Buzzer Enable Buzzer l Disk Value Start 0 1 gt SPI NUP Interval 1 Second s gt Seconds interval Port Definition Zone Status User Manual 13 e m N lt 1 7 Drive Carrier Module The Drive Carrier Module houses a 3 5 inch hard disk drive It is designed for maximum airflow and incorporates a carrier locking mechanism to prevent unauthorized access to the HDD 1 7 1 Disk Drive Status I ndicators Every Drive Carrier has 2 status indicator lights One indicator light is used for Power On Error When this light is GREEN the power is on and everything is functioning normally When the Power On Error light is RED then an error has happened that requires the user s attention The other status indicator light is the hard disk drive access light When the hard disk drive is being accessed this light will flash BLUE In addition both indicator lights are viewable within a 170 arc Disk Activity TT Indicator Disk Status Indicator EPI User Manual 1 7 2 Drive Carrier Lock Indicator Every Drive Carrier is lockable and is fitted with a lock indicator to indicate whether or not the carrier is locked into the chassis or not Each carrier is also fitte
6. d with an ergonomic handle for easy carrier removal Drive Carrier is unlocked Drive Carrier is locked When the Lock Groove is horizontal this indicates that the Drive Carrier is locked Lock and unlock the Drive Carriers by using a flat head screw driver User Manual 15 Chapter 2 Installation of Expansion Chassis 2 1 Installing hard Drives The expansion chassis supports hot swapping allowing you to install or replace a hard drive while the expansion chassis is running 1 Unlock the Disk Trays using a flat head screw driver by rotating the Lock Groove Disk Tray is unlocked Tray Open Button 3 Pull out an empty disk tray ITS User Manual 4 Place the hard drive in the disk tray Turn the disk tray upside down Align the four screw holes of the SAS disk drive in the four Hole A of the disk tray To secure the disk drive into the disk tray tighten four screws on these holes of the disk tray Note in the picture below where the screws should be placed in the disk tray holes Tray Hole A NOTE All the disk tray holes are labelled accordingly User Manual a7 5 Slide the tray into a slot 6 Press the lever in until you hear the latch click into place The HDD Fault LED will turn green when the subsystem is powered on and HDD is good 7 If necessary lock the Disk Tray by turning the Lock Groove 2 2 Setting the DI P Switch of J BOD Controller NOTE Depending on the SAS R
7. e O zo mt o es ore RS232 Port Ready LED le i le e Chassis ID Fault LED HDD LED SAS IN Ports A and B SAS cable must be connected to these ports and to the SAS HBA or other Expansion Chassis s SAS Expansion Port if this chassis is connected in daisy chain Link LED SAS IN and SAS Exp Green indicates SAS IN Port has connected or linked Access LED SAS IN and SAS Exp Blue indicates SAS IN Port is being accessed SAS Expansion Ports A and B SAS cable must be connected to these ports and to other SAS IN Port of other expansion chassis for daisy chaining Chassis ID Dial Used for assigning the Expansion Chassis ID Number Press the upper or lower button to select increase or decrease the Chassis ID Number RS 232 Port Used for upgrading the Firmware of JBOD controller in the Expansion Chassis Fault LED Red LED is on indicates there is problem within the Expansion Chassis If LED is off the Expansion Chassis is in normal condition HDD LED Blue indicates activity on the JBOD controller or disk drives Ready LED Blinking green indicates Expansion Chassis is Powered On and Ready Mute Use this button to silence the alarm beeper If another failure event happens the alarm beeper will sound again and this button can be pressed again to silence alarm O B User Manual 1 5 Power Supply Fan Module PSFM Every JBOD contains two 500W Power Supply Fan
8. n Fail LED Over Temperature LED Voltage Warning LED Reserved for RAID Subsystem Power LED Green indicates power is ON If one of the redundant power supply unit fails this LED will turn to RED and alarm will sound Power Fail LED Turn RED when fan 1 or 2 fails or speed is lower than 3000 RPM for Fan Fail LED Master Fan and 2500 RPM for Slave Fan If system temperature is over 70 C or disk temperatures exceed 55 C the Over Temperature LED will turn RED and alarm will sound Over Temperature LED An alarm will sound if detected voltage in the controller is abnormal and LED will turn RED User Manual ql Voltage Warning LED 1 6 2 LCD Panel Function Buttons Up and Down Use the Up or Down arrow keys to y go through the information on the LCD screen This is also used to move between each menu A This is used to enter the option Select button you have selected Press this button to return to the previous menu NOTE This button can also be used to silence the alarm beeper when in main menu If you are in submenu and a failure event happens press the EXIT button few times as necessary to go back to main menu and press again to silence the alarm Arrow buttons Exit button a2 User Manual 1 6 3 Menu Diagram Model Name Chassis 1D 0 l F W V 1 1 7 l Disk Status ID 001 16 gt S 1 0 33C S 2 0 32C 1 S 15 0 31C S 16 0 30C Power Status Good gt gt P
9. nual 5 When the transfer and firmware update is complete please power cycle the J BOD HyperTerminalPort 1 HyperTerminal File Edit View Call Transfer Help Dl 121 ol cmd gt system upgrade Please Use KModem Protocol for File Transmission Use Q Or q to quit Download before starting KModem 33333 Received 251520Bvtes Buffer Download Complete cmd gt _ Connected 0 01 27 ANSIW 115200 8 N 1 SCROLL CAPS NLIM Capture Print echo 6 Fie Edit View Call Transfer Help Ole elj PSU B HF speed evaluating OK PSU A Monitoring the status PSU B Monitoring the status cmd gt system info 12 Bay system Power num 2 Fan num 2 ChassisId 00 Expander E H 0 03 CPLD Version 01 Vendor ID Proware Hodel proSUN Expande Build time May Connected 0 17 53 ANSIW 115200 8 N 1 SCROLL CAPS NUM Capture Print echo User Manual PES
10. t systi P 1 ease U s Capture to Printer bcol for File Transmission Use Q Or q to quit Download before starting XModem 3333333 y Sends a file to the remote system Z 3 Select your firmware file path and select Xmodem in the communication protocol and click transfer button MN Send File Ei Folder C Documents and Settings 45 dmi AprosUN 6G JBOD Fu Filename eso ocuments and Settings 5 dministratorDieskto Protocol Send Close Cancel User Manual oa 4 Wait for the transfer of file to complete HyperTerminalPort 2 HyperTerminal File Edit View Call Transfer Help cmd gt system upgrade Please Use KModem Protocol for File Transmission Use Q r q to quit Download before starting KModem SSSSSSSSSSSSSSSSSSSS Sending C Documents and Settings Administrator Desktop proSUN 6G JBOD F Packet fizo2 Error checking Checksum ssS S S Retries TN Total retries o Last error p i l iii MITT TT 148K of 245K Elapsed 00 00 37 Remaining 00 00 24 Throughput 4092 cps ij cps bps Connected 0 01 16 Auto detect 115200 8 N 1 SCROLL CAPS NUM Capture Print echo Sending C Documents and Settings Administrator Desktop proSUN 6G JBOD F Packet aa Error checking Checksum Retries o Total retries p Last error Y File AAA 202K of 237K Elapsed 00 00 Remaining 00 00 09 Throughput 3970 cps i cps bps aes User Ma
11. ures the latest SASII 6Gb s interface and designed to fit in with the environments which needed highly reliable and relentless data growth The JBOD Enclosure is also a versatile SAS2 SATA3 Disk Expansion system ideal for high capacity and scalability storage in IT demands Based on the 6G SAS technology the JBOD Enclosure supporting the choice of SAS2 and SATA3 drive configurations to deliver the best cost performance index with higher bandwidth User Manual ENS 1 1 Features Modular architecture Redundant hot swappable components power and cooling modules Easy to use and maintenance Power Supply Power Supply and cooling system contained in 1 module for efficient cooling 500W power supplies to meet the future HDD power consumption Enclosure Hardware expansion slots keep you up to date on the latest technologies Incorporates a cableless design for maximum signal integrity SES Utilizes industry standard SCSI Enclosure Services to monitor enclosure and disk environmental conditions HPI User Manual 1 2 Technical Specifications Form Factor Host Bus Interface Expansion Bus Interface Disk Bus Interface Backplane of Hot Swap Trays Tray Lock Disk Status I ndicator Enclosure Monitoring SES of PS Fan Modules of Fans per Module Power Status I ndicator Fan Status Indicator Power Requirements Relative Humidity Operating Temperature Physical Dimension Weight Without Disk 3U 19 rackmount chassis

Download Pdf Manuals

image

Related Search

Related Contents

PCM 340 Installation Notes  ALAMO user manual and installation guide v  JVC KD-S670 Instruction Manual  Samsung SGH-E620B User Manual  BIOSTAT® B-DCU II con unità BioPAT® DCU Tower  MLINK SWARE FRENCH MANUAL - Produktübersicht... ...www  Nokia PM-3205 Cell Phone User Manual  Bicycle Powered Generator for the University Farm  Code User`s Manual  PTSS165  