1. 4 Selects serial port 4 PS 2 only 5 Selects serial port 5 PS 2 only 6 Selects serial port 6 PS 2 only 7 Selects serial port 7 PS 2 only 8 Selects serial port 8 PS 2 only BAXXXX Selects serial port with a base address of xxxx address must be in hexadecimal Or H Displays help screen NOTES When using the BA option Base Address all four digits must be specified Example for COM1 BA03F8 Use the BA switch only when the serial port is located at a non standard address within the computer A summary of command line switches is always available by starting the program with switch or H switch 14557 N 82nd St 866 746 3015 toll free Scottsdale AZ 86460 wwwgtcocalcomp com 480 9981751 fax SummaSketch III 22 PN A CalComp by TURNING technologies Example To configure a tablet on COM2 for MM SummaSketch format type UIOF 2 SEND Tablet Configuration Utility The SEND tablet configuration utility sends a string of commands to SummaSketch tablets to modify the default tablet settings Command Syntax SEND options Cx Options Description 1 default Selects serial port 1 PC XT AT and PS 2 2 3 4 5 6 7 8 Selects serial port 2 PC XT AT and PS 2 Selects serial port 3 PS 2 only Selects serial port 4 PS 2 only Selects serial port 5 PS 2 only Selects serial port 6 PS 2 only Selects serial port 7 PS 2 only Selects serial port 8 PS 2 only M
2. Command Syntax MM options Options Description 1 Selects serial port 1 PC XT AT and PS 2 2 Selects serial port 2 PC XT AT and PS 2 3 Selects serial port 3 PS 2 only 4 Selects serial port 4 PS 2 only 5 Selects serial port 5 PS 2 only 6 Selects serial port 6 PS 2 only 7 Selects serial port 7 PS 2 only 8 Selects serial port 8 PS 2 only BAXXxx Selects serial port with a base address of xxxx address must be in hexadecimal Or H Displays help screen 14557 N Band St PRC Pree A sere 866 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 21 PN A CalComp by TURNING technologies NOTES When using the BA option Base Address all four digits must be specified Example for COM1 BAO3F8 Use the BA switch only when the serial port is located at a non standard address within the computer A summary of command line switches is always available by starting the program with switch or H switch Example To configure a tablet on COM2 for MM SummasSketch format type MM 2 UIOF Tablet Configuration Utility The UIOF tablet configuration utility configures a tablet for the UIOF Microgrid format regardless of the stylus cursor being used Command Syntax UIOF options Options Description 1 default Selects serial port 1 PC XT AT and PS 2 2 Selects serial port 2 PC XT AT and PS 2 3 Selects serial port 3 PS 2 only
3. Stream Mode lt ESC gt MO Switch Stream Mode lt ESC gt M2 Enable Stylus lt ESC gt MS Enable Four Button Cursor lt ESC gt MC Enable Disable lt CR gt in ASCII formats lt ESC gt MR Enable Disable lt LF gt in ASCII formats lt ESC gt ML Redefine Reset lt ESC gt r b Resume Transmission XON lt CTRL gt Q Diagnostic lt ESC gt U0 Enable Tablet ID lt ESC gt T1 Disable Tablet ID lt ESC gt TO Mode Change to MM 1812 only lt ESC gt z1 Clear All Filters lt ESC gt f0 Enable 15 1 Filter lt ESC gt f1 Enable 3 1 Filter lt ESC gt f2 Enable 7 1 Filter lt ESC gt f3 Display Filter Status lt ESC gt f9 Baud Rate lt ESC gt B b 19 2k lt ESC gt BO 9600 lt ESC gt B1 4800 lt ESC gt B2 2400 lt ESC gt B3 ee 14557 N 82nd St 866 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 28 PN A CalComp by TURNING technologies 1200 lt ESC gt B4 600 lt ESC gt B5 300 lt ESC gt B6 150 lt ESC gt B7 110 lt ESC gt B8 Parity lt ESC gt p b Parity None lt ESC gt p0 Parity Odd lt ESC gt p1 Parity Even lt ESC gt p2 Decimal Enable lt ESC gt d1 Decimal Disable lt ESC gt d0 Report Rate 1 rps lt ESC gt RO 2 rps lt ESC gt R1 5 rps lt ESC gt R2 10 rps lt ESC gt R3 30 rps lt ESC gt R4 60 rps lt ESC gt R5 75 rps lt ESC gt R6 80 rps lt ESC gt R7 Resolution Definable X axis lt ESC gt PX bbbb Y axis lt ESC gt PY bbbb where bbbb is any number fro
4. 480 998 1751 fax SummasSketch III 26 PN A CalComp by TURNING technologies zero 0 zero one 1 z Commands Autobaud Z lt SP gt lt SP gt ASCII BCD report format za binary report format zb 8 data bits no parity z8 8 data bits odd parity z9 increment confirmation zi firmware identification z transducer identification zt UIOF format select zu 16 button cursor enable z6 disable reset zr enable x filter 15 1 ZX enable y filter 3 1 zy enable w filter 7 1 ZW clear all filters ze display filter status zq Appendix C UIOF Microgrid Format Command Summary Command ASCII ASCII Delineator lt ESC gt D b where b can be an ASCII character Code Check lt ESC gt x Self Test lt ESC gt t Coordinate System absolute lt ESC gt M5 relative lt ESC gt M4 Increment Mode command lt ESC gt I bbb where bbb the increment value can be from 000 to 225 Send Configuration lt ESC gt a NOP no operation lt CR gt Send Tablet ID lt ENQ gt 14557 N 82nd St ia a aca 866 746 3015 toll free Scottsdale AZ 85260 www dtcocaicomp com 480 998 1751 fax SummaSketch III 27 PN A CalComp by TURNING technologies Origin lower left corner lt ESC gt FO user defined lt ESC gt F1 center lt ESC gt F2 upper left corner lt ESC gt F3 Report Format binary lt ESC gt MB ASCII BCD lt ESC gt MA Report Modes Point Mode lt ESC gt M1 Remote Request Mode mode command lt ESC gt M3 trigger command lt ESC gt G
5. O O 14557 N Band St Scottsdale AZ 85260 www gtcocaicomp com 866 746 3015 toll free 480 998 1751 fax SummaSketch III 36 PN A CalComp by TURNING technologies KEY e MSB Most Significant Bit e LSB Least Significant Bit e Fa Fo and Fc are flag bits They identify the status of the stylus and cursor buttons e Sx and Sy are the X and Y coordinate signs 1 positive 0 negative e In absolute coordinates the sign is always positive In relative coordinates the sign can be positive or negative e Tis the Tablet Identifier Your choice of 1 or 0 Command controlled e PRis the proximity bit O in prox 1 out of prox e PH is the phasing bit which is always 1 e XO X1 etc and YO Y1 etc are the X and Y coordinate bits UIOF Format Format RS 232C Baud Rate 9600 Number of Data Bits Eight Parity Bit Even Number of Stop Bits Two Data Format Binary Format MSB LSB Transmit 6 5 4 3 2 1 0 Sequence PH 0 0 0 0 T PR 1stbyte 0 0 Fe Fd Fc Fb Fa 2nd byte 0 X5 X4 X3 X2 X1 X0 3rd byte 0 X11 X10 x9 X8 X7 X6 4th byte 0 0 Sx X15 X14 X13 X12 5thbyte 0 Y5 Y4 Y3 Y2 Y1 YO 6th byte 0 Y11 Y10 Y9 Y8 Y7 Y6 7th byte 0 0 Sy Y15 Y14 Y13 Y12 8thbyte 14557 N Band St oar 266 746 3015 toll free Scottsdale AZ 85260 www gtcocaicomp com 480 998 1751 fax SummaSketch III 37 PN A CalComp by TURNING technologies KEY e MSB Most Significant Bit e LSB Least Significant Bit e PRis the prox
6. TABLET 2 C4 Sample Batch File DGMG 2 16 Installs driver DOSSHELL Runs the DOSSHELL environment 14557 N 82nd St Iie ESR Co SE 866 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 15 PN A CalComp by TURNING technologies Running the driver from CONFIG SYS Another way to install the driver is by including TABLET SYS as a device driver in the CONFIG SYS file The system automatically installs the driver each time you boot or turn on the system Line Syntax DEVICE TABLET SYS comport stylus cursor tracking other options NOTE Command options are the same as those running TABLET COM from the DOS prompt or a batch file Most of the command lien arguments described for TABLET COM also work for TABLET SYS The exceptions are the OFF command and the memory location options U E and HI Example For a SummaSketch with a four button cursor attached to COM2 DEVICE TABLET SYS 2 C4 UIOF Microgrid Format Drivers TABLETMG COM enables a SummasSketch Series tablet to emulate a Microsoft Mouse Use when your application s setup menu includes a listing for TABLETMG COM or Microsoft Mouse MOUSE COM and your tablet is configured for use with a 16 button cursor or stylus UIOF Microgrid format Installing the TABLETMG COM Driver Copy the file TABLETMG COM from the drivers utilities disk to your hard drive and run the driver before starting your application Command S
7. computer with a non standard serial port you may specify the IRQ number and the address of the port in hexadecimal by choosing the Allow Detailed Configuration option from the configuration menu before running Configure Digitizer as described above 8 The configuration is now complete and you are ready to use Summagraphics with AutoCAD Exit to the drawing editor and enter Y to save changes Installing the Real Mode Driver for all versions of AutoCAD Copy the file DGMGCOM from the Drivers Utilities disk to your hard drive and run the driver before starting Autodesk applications Command Syntax DGMG com port transducer Parameter Permissible Description Values com port 1 default Tablet is connected to serial port 1 of computer 2 Tablet is connected to serial port 2 of computer 3 Tablet is connected to serial port 3 of computer IBM PS 2 only 4 Tablet is connected to serial port 4 of computer IBM PS 2 only transducer CP Selects two button stylus C16 default Selects the 16 button cursor OFF OFF Disables the driver Examples For a SummaSketch Professional with a 16 button cursor connected to COM2 type the following at the DOS prompt DGMG 2 16 a 14557 N 82nd St a aA reaa A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 13 PN A CalComp by TURNING technologies Sample Batch File DGMG 2 16 Installs driver CD ACAD Changes to
8. du Canada 14557 N 82nd St cates a 866 746 3015 toll free Scottsdale AZ 25260 www gtcocaicomp com 480 998 1751 fax SummaSketch III 39 CalComp by TURNING technologies European Union Emission Directive This product is in conformity with the protection requirements of EU Council Directive 89 366 ECC on the approximation of the laws of the Member States relating to electromagnetic compatibility This product has been tested and found to comply with the limits for Class B Information Technology Equipment according to CISPR 22 European Standard EN55022 The limits for Class B equipment were derived for typical industrial environments to provide reasonable protection against interference with licensed communication devices European Union WEEE Directive The manufacture of this equipment required the extraction and use of natural resources It may contain hazardous substances that could impact health and the environment e In order to avoid the dissemination of the hazardous substances into the environment and to diminish the pressure on our natural resources GTCO CalComp by Turning Technologies encourages you to return this product to the appropriate take back system facility These facilities reuse or recycle most of the materials in this equipment in a responsible way e The crossed out wheeled bin symbol below invites you to use these take back systems e If you need more information about the collection reuse and recyc
9. is connected Type COM7 or COM2 and press ENTER 8 The configuration is now complete and you are ready to use Summagraphics with AutoCAD Exit to the drawing editor and enter Y to save changes Installing the Protected Mode Driver for AutoCAD Rel 12 1 Copy the protected mode drivers from the Summagraphics Drivers Utilities diskette to the ACAD DRV directory 2 Startup AutoCAD The AutoCAD Drawing Editor appears on the screen 3 Type CONFIG and press ENTER A listing of the current configuration appears on the screen Choose ENTER to proceed to the configuration menu 4 At the configuration menu select Configure Digitizer AutoCAD asks if you want a new digitizer Since you are installing for the first time type Y and then select ENTER A listing of digitizer options appear on the screen Choose Summagraphics Microgrid v 1 3 ADI 4 2 by Summagraphics and press ENTER 14557 N 82nd St a aA reaa A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 hai SummaSketch III 12 PN A CalComp by TURNING technologies 5 You are prompted for the size of the tablet Select the number corresponding to your tablet size and select ENTER 6 You are prompted for the number of buttons on your pointing device stylus or cursor Enter the appropriate number and press ENTER 7 You are now asked to name the serial port to which your tablet is connected Type COM7 or COM2 and press ENTER If you are using a
10. stylus switch 3 being mapped to the middle mouse button and cursor stylus switch 4 being mapped to both the right and left mouse button Tracking Options The following options will work only if the application is set up to use a Microsoft Mouse MOUSE COM Applications that are compatible specifically with TABLET COM should configure tracking automatically or allow you to configure tracking through the application s set up utility The use of the following options will be overridden by the application 14557 N 82nd St a aA reaa A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 30 PN CalComp by TURNING technologies Relative Mode R Relative mode is the default setting There are four relative mode options S Sets both horizontal and vertical sensitivity Range 0 99 default 50 H Sets only the horizontal sensitivity Range 0 99 default 50 N Sets only the vertical sensitivity Range 0 99 default 50 P This option is the ballistic gain profile It controls acceleration of the screen cursor TABLET COM comes with four built in ballistic gain profiles Slow Moderate Fast and Unaccelerated Specify 1 2 3 or 4 Absolute Mode A Absolute mode maps the tablet s entire active area to the computer screen Relative mode options S H V M should not be used in Absolute mode NOTE Applications accept input from MOUSE COM as either absol
11. the reseller s purchase order A nominal Warranty Handling Fee will be charged after the first 90 days of use and calculated from the date of original consumer purchase This payment may be made by Visa MasterCard or American Express A copy of the sales receipt or invoice will be required for warranty verification Conditions Except as specified below this warranty covers all defects in material or workmanship in the products The following are not covered by the warranty 1 Any product on which the serial number has been defaced modified or removed if applicable 2 Damage deterioration or malfunction resulting from a Accident misuse abuse neglect fire water lightning or other acts of nature unauthorized modification for any purpose unauthorized product modification or failure to follow instructions supplied with the product b Repair or attempted repair by anyone not authorized by GTCO CalComp by Turning Technologies c Any damage in shipment of the product claims must be presented to the carrier d Any other cause which does not relate to a manufacturing defect 3 Any product not sold or leased to a consumer within six months of GTCO CALCOMP BY TURNING TECHNOLOGIES original sale date GTCO CalComp by Turning Technologies will pay all labor and material expenses for covered items but will not pay for the following 1 Removal or installation charges 14557 N Band St 866 746 3015 toll free Scottsdale AZ 85
12. 2014 GTCO CalComp by Turning Technologies Inc SummaSketch Ill is a trademark of GTCO CalComp by Turning Technologies Inc All other products and company names are the trademarks or registered trademarks of their respective owners The information contained in this document is subject to change without notice GTCO CalComp by Turning Technologies assumes no responsibility for technical or editorial errors or omissions that may appear in this document or for the use of this material Nor does GTCO CalComp by Turning Technologies make any commitment to update the information contained in this document This document contains proprietary information which is protected by copyright All rights reserved No part of this document can be photocopied or reproduced in any form without the prior written consent of GTCO CalComp by Turning Technologies Inc 14557 N Band St Ta oar 866 746 3015 toll free Scottsdale AZ 85260 www gtcocaicomp com 480 998 1751 fax
13. 260 wiwy dtcocaicomp com 480 998 1751 fax SummaSketch III 41 PN A CalComp by TURNING technologies 2 Costs for initial technical adjustments setup including adjustment of user controls 3 Certain shipping charges Payment of shipping charges is discussed in the next section of this warranty 4 Packaging costs Customers should keep their boxes Warranty Service Procedures 1 To obtain service on your GTCO CalComp by Turning Technologies product contact the Technical Support Department to receive a Return Material Authorization Number RMA and shipping instructions by calling 1 866 746 3015 2 Ship the product to GTCO CalComp by Turning Technologies with the RMA marked clearly on the outside of the box Without a clearly marked RMA on the shipping box GTCO CalComp by Turning Technologies reserves the right to refuse the shipment 3 Although you must pay any shipping charges to ship the product to GTCO CalComp by Turning Technologies for warranty service GTCO CalComp by Turning Technologies will pay the return shipping charges for ground shipment Other shipping options are available at an additional fee 4 Whenever warranty service is required the original dated sales invoice or a copy must be presented as proof of warranty coverage and should be included in shipment of the product Please also include your name address telephone number fax number email address and a description of the problem 5 If GTCO C
14. 4557 N 82nd St ee a A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 hai SummasSketch III 9 PN A CalComp by TURNING technologies Command Syntax DGMG com port transducer Parameter Permissible Description Values com port 7 1 default Tablet is connected to serial port 1 of computer 2 Tablet is connected to serial port 2 of computer 3 Tablet is connected to serial port 3 of computer IBM PS 2 only 4 Tablet is connected to serial port 4 of computer IBM PS 2 only transducer CP Selects two button stylus C16 default Selects the 16 button cursor OFF OFF Disables the driver Examples For a SummaSketch Professional with a 16 button cursor connected to COM2 type the following at the DOS prompt DGMG 2 16 Sample Batch File DGMG 2 16 Installs driver CD ACAD Changes to application directory ACAD ACAD Runs application ACAD Configuring AutoCAD for the Real Mode Driver After installing the ADI driver and restarting the computer startup AutoCAD and follow the instructions listed below 1 If you are running AutoCAD release 11 select Configure AutoCAD from the AutoCAD Main Menu and press ENTER to proceed to the configuration menu If you are running AutoCAD release 12 select Configure from the File pop down menu and select ENTER to proceed to the configuration menu 14557 N 82nd St Iie ESR Co SE 866 746 3015 toll free Scottsdale AZ 85260 w
15. GPMG EXP Protected Mode Driver Use this driver if you have a release 11 or 12 version of the 386 DOS extender version of AutoCAD and wish to take advantage of AutoCAD s protected mode capabilities e DGMG COM Real Mode Driver Use this driver with all DOS versions of AutoCAD Installing the Protected Mode Driver for AutoCAD Rel 11 1 Copy the drive file from the diskette to your AutoCAD directory and rename it to ADIDIG EXP Example COPY A ADIDVR DGPMG EXP C ACAD ADIDIG EXP 14557 N 82nd St a aA reaa A 866 746 3015 toll free Scottsdale AZ 85260 Wii Ve gtc ocaicomp com 480 998 175 fax SummaSketch III 11 PN A CalComp by TURNING technologies 2 Startup AutoCAD The main menu will appear on the screen 3 Select Configure AutoCAD from the screen menu A listing of the current configuration appears on the screen Press ENTER to proceed to the configuration menu 4 Atthe configuration menu select Configure Digitizer AutoCAD asks if you want a new digitizer Since you are installing for the first time type Y and then select ENTER A list of digitizer options appear on the screen Choose ADI P386 digitizer and press ENTER 5 You are prompted for the size of your tablet Select the number corresponding to your tablet size and choose ENTER 6 You are prompted for the size of tablet Select the number corresponding to your tablet size and press ENTER 7 You are now asked to name the serial port to which your tablet
16. GSUMMA COM real mode driver Use the driver with all DOS versions of AutoCAD Installing the Protected Mode Driver for AutoCAD Rel 11 1 Copy the drive file from the diskette to the AutoCAD directory and rename it to ADIDIG EXP Example COPY A ADIDVR DGPSUMMA EXP C ACAD ADIDIG EXP 2 Startup AutoCAD The main menu will appear on the screen 3 Select Configure AutoCAD from the screen menu A listing of the current configuration appears on the screen Press ENTER to proceed to the configuration menu 4 At the configuration menu select Configure Digitizer AutoCAD asks if you want a new digitizer Since you are installing for the first time type Y and press ENTER A list of digitizer options appear on the screen Select AD P386 digitizer and select ENTER 5 You are prompted for the size of the tablet Choose the number corresponding to your tablet size and press ENTER 6 You are prompted for the number of buttons on the pointing device stylus or cursor Select the appropriate number and press ENTER 7 You are now asked to name the serial port to which your tablet is connected Type COM7 or COM2 and press ENTER 14557 N 82nd St a aA reaa A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 hai SummasSketch III 8 PN A CalComp by TURNING technologies 8 The configuration is now complete and you are ready to use Summagraphics with AutoCAD Exit to the drawing editor and enter Y to sa
17. Selects no parity configuration Or H Displays help screen NOTES When using the BA option Base Address all four digits must be specified Example for COM1 BA03F8 Use the BA switch only when the serial port is located at a non standard address within the computer A summary of command line switches is always available by starting the program with switch or H 14557 N 82nd St 866 746 3015 toll free Scottsdale AZ 85260 www dtcocaicomp com 480 998 1751 hai SummaSketch III 20 PN A CalComp by TURNING technologies Test Results After running MMTEST you should see X Y coordinate data streaming on the screen The date is in the following format XXXXXX YYYYYY F P where X is the X coordinate data and Y is the Y coordinate data F is the number of the cursor stylus button being pressed 1 2 3 or 4 P is proximity 0 is in proximity 1 is out of proximity Move the cursor stylus around on the tablet surface You should see the X Y coordinates changing Press each of the cursor stylus buttons one at atime You should see the F field changing accordingly Lift the cursor stylus a few inches off the tablet surface You should see the P field change from 0 to 1 Exiting MMTEST To exit MMTEST type lt CTRL gt X Changing Tablet Formats MM COM UIOF COM SEND COM MM Tablet Configuration Utility The MM Utility configures a tablet to MM SummaSketch format regardless of the cursor stylus being used
18. SummasSketch III 1 PN A CalComp by TURNING technologies SUMMASKETCH III USER S GUIDE Table of Contents Overview 3 About this Manual 3 Installing the Tablet 5 Caring for the Tablet 5 Changing the Stylus Tips 6 Guidelines for Installing the Drivers Utilities 6 Summagraphics Drivers 6 Autodesk Application Drivers 6 MM SS Format Drivers 6 UIOF Microgrid Format Drivers 10 Summagraphics Tablet Driver Mouse Emulator 13 MM SS Format Drivers 13 UIOF Microgrid Format Drivers 15 Summagraphics Utilities 17 Resetting the Tablet MMRST and UIOFRST 17 MMRST Command 17 UIOFRST Command 18 Testing the Tablet MMTEST 19 MMTEST Tablet Test Utility 19 Changing Tablet Formats MM COM UIOF COM SEND COM 20 MM Tablet Configuration Utility 20 UIOF Tablet Configuration Utility 21 SEND Tablet Configuration Utility 22 Appendices 23 A What to do if a Problem Arises 23 B MM SummasSketch Format Command Summary 24 C UIOF Microgird Format Command Summary 26 D TABLET COM amp TABLETMG COM Command Options 29 Cursor Stylus Button Mapping Options 29 Tracking Options 29 Memory Location Options U E H1 31 E Configuring AutoCAD Rel 12 for Windows 31 14557 N 82nd St RI ATENE AA SE 866 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummasSketch III 2 PN A CalComp by TURNING technologies Configuring AutoCAD for Windows 31 Digitizer Mode vs Mole Mode 33 F Interface Power Cable Pi
19. able from your Summagraphics dealer or directly from Summagraphics Guidelines for Installing the Drivers Utilities The Drivers and Utilities found on the TabletWorks CD in the Archives directory are used when the tablet needs to be reset In the Archives directory select the TabletWorks CD V5_2 directory and the SGDOSUTL subdirectory ADIDVR The MM and UIOF format drivers for Autodesk applications both real mode and protected mode versions UTILITY Contains the following utilities MMRST UIOFRST MMTEST MM UIOF and SEND Summagraphics Drivers Autodesk Application Drivers MM Summasketch Format Drivers Use these drivers if you have configured AutoCAD for a real or protected mode ADI driver and your tablet has a 4 button cursor or stylus attached 14557 N 82nd St AIEEE ERE 866 746 3015 toll free Scottsdale AZ 85260 Vi WV gtc ocaicomp com 480 9981751 fax SummasSketch III 7 PN A CalComp by TURNING technologies NOTE Summagraphics ADI drivers are less likely to encounter initialization when shelling out of AutoCAD therefore Summagraphics recommends using the ADI drivers supplied on the Drivers Utilities disk instead of AutoCAD s drivers Summagraphics provides a protected and real mode driver e DGPSUMMA EXP protected mode driver Use the driver if you have a release 11 or 12 version of the 386 DOS extender version of AutoCAD and wish to take advantage of AutoCAD s protected mode capabilities e D
20. alComp by Turning Technologies determines that the unit is not defective within the terms of the warranty the consumer shall pay the cost of all freight charges as well as any repair charges Technical Support Web based Technical Support is available free of charge at www gtcocalcomp com where current driver releases as well as comprehensive technical support troubleshooting Technical Bulletins and FAQs can be found Telephone Technical Support is available free of charge to the original consumer for a period of 90 days from the date of purchase of the product Please contact our Technical Support Department at 1 866 746 3015 or fax your request to 480 998 1751 Disclaimer of Unstated Warranties The warranty printed above is the only warranty applicable to this purchase ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED Assuming the warranty above stated is otherwise applicable it is expressly understood and agreed that GTCO CalComp by Turning Technologies sole liability whether in contract tort under any warranty in negligence or other shall be for the repair or replacement of the defective parts and under no circumstances shall GTCO CalComp by Turning Technologies be liable for special indirect or 14557 N 82nd St ay S g 266 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummaSk
21. application directory ACAD ACAD Runs application ACAD Configuring AutoCAD for the Real Mode Driver After installing Summagraphics ADI driver start AutoCAD and follow the instructions below 1 If you are running AutoCAD release 11 select Configure AutoCAD from the AutoCAD Main Menu and press ENTER to proceed to the configuration menu If you are running AutoCAD release 12 select Configure from the File pop down menu and select ENTER to proceed to the configuration menu 2 At the configuration menu select Configure Digitizer AutoCAD asks if you want a new digitizer Since you are installing for the first time type Y and press ENTER A list of digitizer options appear on the screen If you are running AutoCAD release 11 select Autodesk Device Interface and press ENTER If you are running AutoCAD release 12 choose ADI Digitizer Real Mode and select ENTER 3 You are prompted for the hexadecimal interrupt code INTOXXh lt 79 gt Press ENTER to accept the default of 79 and return to the configuration menu 4 Ifyou are running AutoCAD release 11 select Exit to Main Menu and press ENTER If you are running AutoCAD release 12 select Exit to Drawing Editor and press ENTER 5 Type Y to save configuration changes and select ENTER 6 The configuration is now complete and you are ready to use Summagraphics with AutoCAD Summagraphics Tablet Driver Mouse Emulator MM SummeSketch Format Driver TABLET COM enables a SummaSk
22. contact Technical Support at 1 866 746 3015 or email us at gtco support gtcocalcomp com Appendix B MM SummasSketch Format Command Summary Command ASCII Autobaud lt SP gt Axis Update Mode command G value lt SP gt to lt DEL gt Code Check X Coordinate System absolute F relative E Echo K Increment Mode command l increment value lt SP gt to lt DEL gt Origin upper left b lower left c Report Modes Point Mode B Remote Request Mode 14557 N Band St PUI TERS E S 866 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 25 PN A CalComp by TURNING technologies mode command D trigger command P Stream Mode Switch Stream Mode A Report Rate 110 rps Q 50 rps R 10 rps S 2 rps T Reset lt Nul gt Resolution Definable command r X axis resolution low byte Hex 00 to FF X axis resolution high byte Hex 00 to 17 Y axis resolution low byte Hex 00 to FF Y axis resolution high byte Hex 00 to 17 Resolution Predefined 1 Ipi l 2 lpi n 4 Ipi p 100 Ipi d 200 Ipi e 10 pmm f 400 Ipi g 500 Ipi h 20 Ipi i 1000 Ipi j 40 lpmm q 2000 Ipi S 2032 Ipi u 2540 Ipi 12 x 12 only v Resume Transmission XON lt CTRL gt Q Self Test t Send Model ID lt ENQ gt Sent Test Results w Send Configuration a Stop Transmission XOFF lt CTRL gt S Tablet Identifier aaa 14557 N 82nd St pCi Pree i EA 866 746 3015 toll free Scottsdale AZ 25260 www gtcocaicomp com
23. d if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Reorient or coil cables e Consult the dealer or an experienced Radio TV technician for help NOTE Any cables the user adds to the device must be shielded to be in compliance with the FCC standards Any unauthorized modification to this device could result in the revocation of the end user s authority to operate this device Canada This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of the Canadian Department of Communications Le present appareil num rique n emet pas bruits radioelectriques depassant les limites applicables aux appareils num riques de Classe B prescrites dans le r glement sur le brouillage radioelectrique edicte par le Ministere des Communications
24. default Selects MM format serial configuration U Selects UIOF format serial configuration BAXXXX Selects serial port with a base address of xxxx address must be in hexadecimal CXXX Transmit command characters xxx until carriage return required options Or H Displays help screen NOTES SEND COM can transmit at various baud rates and parities and can transmit commands from an ASCII file For further information refer to SEND DOC or invoke SEND COM with the Help option example SEND When using the BA option Base Address all four digits must be specified Example for COM1 BAO3F8 Option C must be the last option on the command line There is no space between the C switch and the commands that follow To transmit ASCII control characters precede a printable ASCII character with UU examples ESC UU NULL UU BELL UUG The BA option should only be used when the serial port is located at a non standard address within the computer 14557 N Band St 866 746 3015 toll free Scottsdale AZ 85260 www gtcocaicomp com 480 998 1751 fax SummaSketch III 23 PN A CalComp by TURNING technologies e Asummary of command line switches is always available by starting the program with the or H options Examples e To configure a tablet on COM1 transmitting in MM format to ASCII format output type SEND 1 Cza e To configure a tablet on COM2 transmitting in MM format to binary
25. etch III 42 PN A CalComp by TURNING technologies consequential damages The price stated and paid for the equipment is a consideration in limiting GTCO CalComp by Turning Technologies liability Notice Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state or province to province To obtain service on your GTCO CalComp by Turning Technologies product call our Technical Support Department at 1 866 746 3015 or fax us at 480 998 1751 We can also be contacted through our website at www gtcocalcomp com in US at EUOffice gtcocalcomp com in Germany at infos calcomp fr in France Important All products returned to GTCO CalComp by Turning Technologies for service must have prior approval in the form of a Return Merchandise Authorization Number RMA which can be obtained by calling the Technical Support Department 14557 N Band St corde or pepe 866 746 3015 toll free Scottsdale AZ 85260 www gtcocaicomp com 490 9981751 fax SummaSketch III 43 PN A CalComp by TURNING technologies Corporate Headquarters 14557 N 82 Street Scottsdale Arizona 85260 Tel 1 866 746 3015 Support 1 866 746 3015 Fax 480 998 1751 www gtcocalcomp com Support 1 866 746 3015 SUMMASKETCH III Copyright
26. etch Series tablet to emulate a Microsoft Mouse Use when your application s setup menu includes a listing for TABLET COM or Microsoft Mouse 14557 N 82nd St a aA reaa A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 hai SummaSketch III 14 PN A CalComp by TURNING technologies MOUSE COM and your tablet is configured for use with a 4 button cursor or stylus MM SummasSketch format Installing the MM SummaSketch Format Driver Copy the file TABLET COM from the drivers utilities disk to your hard drive and run the driver before starting your application Command Syntax TABLET com port stylus cursor tracking other options Parameter Permissible Values Description com port 1 default Tablet is connected to serial port 1 of computer 2 Tablet is connected to serial port 2 of computer 3 Tablet is connected to serial port 3 of computer IBM PS 2 only 4 Tablet is connected to serial port 4 of computer IBM PS 2 only BAXXXX Selects serial port with a base address of xxxx address must be in hexadecimal x Selects serial port with IRQ line number x 2 7 OFF OFF Disables the driver stylus cursor CP Selects two button stylus IC3 Selects three button stylus C4 default Selects four button cursor NOTE Refer to Appendix D for TABLET COM button mapping tracking and memory location options Examples For a SummaSketch with a 4 button cursor connected to COM2
27. fault serial communication configuration 9600 baud 7 data bits even parity and 2 stop bits e Use the BA switch only when the serial port is located at a non standard address within the computer e Asummary of command line switches is always available by starting the program with switch Or H Example To reset an UIOF Microgrid format tablet connected to COM2 type UIOFRST 2 14557 N B2nd St Iie ESR Co SE 866 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 19 PN CalComp by TURNING technologies Testing the Tablet MMTEST MMTEST Tablet Test Utility The MMTEST utility verifies that the MM SummaSketch or UIOF Microgrid format tablet is working properly Command Syntax MMTEST options Options Description M default Selects MM format configuration when tablet is configured for MM formatter has 4 button cursor or stylus attached U Selects UIOF format configuration when tablet is configured for UIOF format or has a 16 button cursor attached 1 Selects serial port 1 PC XT AT and PS 2 2 Selects serial port 2 PC XT AT and PS 2 3 Selects serial port 3 PS 2 only 4 Selects serial port 4 PS 2 only 5 Selects serial port 5 PS 2 only 6 Selects serial port 6 PS 2 only 7 Selects serial port 7 PS 2 only 8 Selects serial port 8 PS 2 only BAXXXX Selects serial port with a base address of xxxx address must be in hexadecimal N
28. format type SEND 2 Czb e To configure a tablet on COM1 transmitting in UIOF format to stream mode type SEND 1 U CUU MO Appendices Appendix A What to do if a Problem Arises You should have no issues with your SummaSketch However if a problem arises first ensure that you have installed the tablet as described in the manual Then follow the checklist below Problem Solution Power prox light is not on 1 Make sure the power switch is in the ON position 2 Check that the power supply is plugged into the interface cable 3 Inspect to see the power supply is plugged into a working electrical outlet 4 Check that the I O cable is plugged into the proper jack on the back of the tablet Screen cursor does not move when 1 Check that the application is move the stylus cursor configured for the proper stylus cursor e 14557 N 82nd St I ATENE AA EE 866 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 24 PN A CalComp by TURNING technologies 2 Reset the tablet and restart the application Buttons on the stylus cursor don t work 1 Check to see the application is configured for the proper tablet driver 2 Run MMTEST to see if the buttons are working properly If the problem persists it is probably in the configuration of the application software Contact the application developer or your local dealer for assistance If you have a tablet problem
29. imity bit 0 in prox 1 out of prox e Tis the Tablet Identifier e PHis the phasing bit which is always 1 e Fa through Fe are the flag bits They identify the status of the cursor buttons T D T a T A T io o 4 Button Cursor 16 Button Cursor None 1 zZ e 3 p 2 3 4 TMwWOF MOAN TUAUAKRAWDN gt ao o0c oe 000 00 00 0000 O einen Oe eee O Os a aa Oo O0 OC Off SB SH HSH OO COCO O lt O Of KS OO KH KH OO OO Oe Oe OK OH OK OAH OH CO Oo XO X1 etc and YO Y1 etc are the X and Y coordinate bits The coordinates are in counts of resolution not inches or millimeters Sx and Sy are the X and Y coordinate signs 1 is negative and 0 is positive 14557 N Band St a sai SOs ET ccs 866 746 3015 toll free Scottsdale AZ 25260 www gtcocaicomp com 480 998 1751 fax SummaSketch III 38 PN A CalComp by TURNING technologies Regulatory Statements and Warranty Radio and Television Interference The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits of a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy an
30. iww gtcocaicomp com 480 998 1751 fax SummasSketch III 10 PN A CalComp by TURNING technologies 2 Atthe configuration menu select Configure Digitizer AutoCAD asks if you want a new digitizer Since you are installing for the first time type Y and press ENTER A list of digitizer options appear on the screen If you are running AutoCAD release 11 select Autodesk Device Interface and press ENTER If you are running AutoCAD release 12 choose ADI Digitizer Real Mode and select ENTER 3 You are prompted for the hexadecimal interrupt code INTOXXh lt 79 gt Press ENTER to accept the default of 79 and return to the configuration menu 4 Ifyou are running AutoCAD release 11 select Exit to Main Menu and press ENTER If you are running AutoCAD release 12 select Exit to Drawing Editor and press ENTER 5 Type Y to save configuration changes and select ENTER 6 The configuration is now complete and you are ready to use Summagraphics with AutoCAD UIOF Microgrid Format Drivers Use these drivers if you have configured AutoCAD for a real or protected mode ADI driver and if your tablet has a 16 button cursor attached NOTE Summagraphics ADI drivers are less likely to encounter initialization problems when shelling out of AutoCAD therefore Summagraphics recommends using the ADI drivers supplied on the Drivers Utilities disk instead of AutoCAD s drivers Summagraphics provides both a protected and real mode driver e D
31. ling systems in your area please contact your local or regional waste authority e Further information about the responsible end of life management of this and other GTCO CalComp by Turning Technologies products is available on our website at www gtcocalcomp com 14557 N Band St oar 866 746 3015 toll free Scottsdale AZ 28260 wwvw dtcocaicomp com 480 998 1751 fax SummasSketch III 40 x CalComp by TURNING technologies Limited Warranty for SummasSketch III GTCO CalComp by Turning Technologies Inc warrants these products to be free from defects in material and workmanship under the following terms Complete and return the enclosed warranty registration card to ensure that your products are covered with this warranty Coverage Parts and labor are warranted for one 1 year from the date of the first consumer purchase for the digitizer tablet controller transducers and tablet accessories Power supply and cables are also warranted for one 1 year This warranty applies to the original consumer purchaser only Within the European Union the warranty period is two 2 years as mandated by the EU Contact your local dealer or distributor for additional warranty information Warranty is only valid if original consumer s purchase or lease date is less than or equal to six months from the original GTCO CalComp by Turning Technologies sale date This information will be captured by the system serial number and confirmed by
32. m 0000 to 1016 Resolution Predefined 1 Ipi lt ESC gt C8 2 lpi lt ESC gt C9 4 Ipi lt ESC gt CA 100 Ipi lt ESC gt C7 200 Ipi lt ESC gt CO 10 pmm lt ESC gt C1 400 Ipi lt ESC gt C6 500 Ipi lt ESC gt C4 20 pmm lt ESC gt C5 1000 Ipi lt ESC gt C2 40 lpmm lt ESC gt C3 2000 Ipi lt ESC gt CS or lt ESC gt Cs 14557 N Band St Scottsdale AZ 85260 866 746 3015 toll free www gtcocaicomp com 400 990175 fax SummaSketch III 29 PN A CalComp by TURNING technologies 2032 Ipi lt ESC gt CB 2540 lt ESC gt CD 1201 only Appendix D TABLET COM amp TABLETMG COM Command Options Cursor Stylus Button Mapping Options Command Syntax CM This allows a user defined mapping of the cursor stylus buttons The CM argument is followed by 1 4 digits that specify which cursor stylus switches are assigned to standard mouse buttons Each digit represents the value of a cursor stylus switch and the position represents the mouse button that it is assigned to The first digit after the CM argument corresponds to the left mouse button the second digit to the right mouse button the third digit to the middle mouse button and the fourth digit corresponds to an emulation of both the left and right mouse buttons being pressed simultaneously Example TABLET CM2134 The above example shows cursor stylus switch 2 being mapped to the left mouse button cursor stylus switch 1 being mapped to the right mouse button cursor
33. mmunication port Tighten the thumbscrews e Join the power cable into the jack on the back of the serial cable connection on the computer Attach the power supply end to a power outlet or power strip e Insert the pointing tool connector into the socket labeled POINTER Caring for SummasSketch IlI Below are basic guidelines for the car and maintenance of the SummaSketch tablet e Turn the tablet and computer off and unplug them both before cleaning Also unplug the power supply e To clean the SummaSketch tablet wipe with damp lint free cloth and a mild detergent solution Do not use abrasive cleaners on the tablet surface e Never disassemble the SummasSketch tablet There are no user serviceable parts inside e When you turn off the computer also power down the tablet e Never scratch or mar the tablet surface e Do not immerse the SummasSketch tablet or accessories in liquid e Do not trace through metal or metallized paper Never use metal objects such as metal or metal edged rulers on the tablet 14557 N Band St PRC Pree A sere 866 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummasSketch III 6 PN A CalComp by TURNING technologies Changing the Stylus Tip The stylus is shipped with a non marking refill tip already installed To change the stylus tip unscrew the cap and pull the refill straight out e Insert the new refill and screw on the cap Non marking stylus tips are avail
34. n 1 GROUND Protective Ground 2 RXD Receive RS 232C Data from Host 3 _ TXD Transmit RS 232C Data from Host 4 _ ft RTS Request To Send 5 CTS Clear To Send 6 DSR Data Set Ready 7 GROUND Signal Ground 20 DTR Data Terminal Ready Appendix G 9 to 25 Pin Serial Adapter Wiring Diagram The table below identifies the wiring of the Summagraphics 9 to 25 pin serial adapter If you want to use an adapter other than the one supplied make sure that it has the same specifications shown below 9 Pin Female 25 Pin Male Connector Connector OOnN oO akWNH Ratan O 14557 N 82nd St 866 746 3015 toll free Scottsdale AZ 85260 www gtcocaicomp com 480 998 1751 fax PN A CalComp SummasSketch MM Format Format Baud Rate Number of Data Bits Parity Bit Number of Stop Bits Data Format by TURNING technologies Appendix H Communications Parameters RS 232C 9600 Eight Odd One Binary Format MSB 7 6 5 3 2 PH PR T Sx Sy Fc 0 X6 X5 X4 X3 X2 0 X13 X12 X11 X10 x9 0 Y6 Y5 Y4 Y3 Y2 0 Y13 Y12 Y11 Y10 Y9 Stylus Cursor Buttons Fc None Pressed None Pressed 0 Tip Button 1 0 Barrel Button 2 0 Tip and Barrel 3 0 4 1 1 2 0 1 3 1 1 4 1 2 3 1 2 4 1 1 2 3 1 1 2 4 1 2 3 4 1 1 2 3 4 1 Fb X1 X8 Y1 Y8 LSB Fa x0 X7 YO Y7 T io OoOoo oO Oo oO SummasSketch III 35 Transmit Sequence 1stbyte 2nd byte 3rd byte 4th byte 5th byte v O O O Om
35. n Assignments 34 G 9 to 25 Pin Serial Adapter Wiring Diagram 34 H Communication Parameters 35 Regulatory Statements and Warranty 38 Radio and Television Interference 38 Canada 38 European Union Emission Directive 39 European Union WEEE Directive 39 Warranty for U S Canada 40 14557 N 82nd St NEIERE 866 746 3015 toll free Scottsdale AZ 85260 www gtcocaicomp com 480 998 1751 fax SummasSketch III 3 PN CalComp by TURNING technologies About this Manual Overview This manual is your guide to using SummasSketch tablet and the SummaSketch Drivers Utilities software It assumes you have experience with basic DOS tasks such as changing directories copying files and creating batch files If you are unfamiliar with any of these tasks refer to a DOS user s manual before continuing Introduction Below is information to get you acquainted with your new SummaSketch tablet What are the SummaSketch tablet formats Your tablet can operate in either of two formats e MM SummaSketch Format e UIOF Microgrid Format Your tablet automatically defaults to one of these formats depending on which stylus or cursor is attached when the tablet is powered up If you have a Then your default tablet format is Stylus MM SummaSketch 4 button cursor MM SummasSketch 16 button cursor UIOF Microgrid How do I change between formats e Change stylus or cursor and repower the tablet e Use the software utilities provided on the SummaSke
36. oCAD prompt Response AutoCAD prompt Response AutoCAD prompt Do you want to configure your digitizer as a mole Type Y Do you want an audible mole con Type Y if you like beeps N if not Do you want a visible mole context state indicator Type Y Do you want to assign a CURSOR BUTTON to toggle modes Type Y Press ant button except the pick button now Select the side button on the stylus or any button except the pick button on the 4 or 16 button cursor Do you want to assign a PRIMARY MOLE area Type N Do you want to assign a secondary MOLE area Type Y Enter lower left hand corner now 14557 N 82nd St a aa reaa A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 33 PN A CalComp by TURNING technologies Response Digitize the lower left hand dot on the AutoCAD template s screen pointing area AutoCAD prompt Enter upper left hand corner now Response Digitize the upper left hand dot on the AutoCAD template s screen pointing area AutoCAD prompt Do you want a primary toggle area Response Type N AutoCAD prompt Do you want a secondary toggle area Response Type N 8 On the Configuration menu type ENTER twice to save configuration changes and return to the drawing editor 9 Arrange your template as you normally would Refer to the AutoCAD Interface Installation and Performance Guide or third party template manual fo
37. ogram transmits in the MM SummaSketch default serial communication configuration 9600 baud 8 data bits odd parity and 1 stop bit e Use the BA switch only when the serial port is located at a non standard address within the computer e Asummary of command line switches is always available by starting the program with switch or H Example To reset an MM SummaSketch format tablet connected to COM2 type MMRST 2 14557 N Band St PRC Pree A sere 866 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 18 PN A CalComp by TURNING technologies UIOFRST Command The UIOFRST command resets a tablet that is configured for UIOF Microgrid format and has a 16 button cursor or stylus attached Command Syntax UIOFRST options Options Description 1 Selects serial port 1 PC XT AT and PS 2 2 Selects serial port 2 PC XT AT and PS 2 3 Selects serial port 3 PS 2 only 4 Selects serial port 4 PS 2 only 5 Selects serial port 5 PS 2 only 6 Selects serial port 6 PS 2 only 7 Selects serial port 7 PS 2 only 8 Selects serial port 8 PS 2 only BAXXXX Selects serial port with a base address of xxxx address must be in hexadecimal N Selects no parity configuration Or H Displays help screen NOTES e When using the BA option Base Address all four digits must be specified Example for COM1 BA03F8 e This program transmits in the UIOF Microgrid de
38. only when a non standard serial address is used in the computer Memory Location Options U E and HI These options allow you to maximize the amount of memory available for DOS application programs Maneuver a majority of the TABLET COM driver to a memory location outside of the 640K area used by most application programs The U command moves the driver to the upper memory area between 640K and 1 MB The ZE command shifts the driver into expanded memory The HI command moves the driver into the high memory area between 1 MB and 1 064 MB Your computer system needs to support those options before they can be used The designated memory must be installed as RAM To use E you must have either expanded memory hardware such as an Intel Above Board or a software driver such as EMM386 or QEMM in your machine To use HI you must have an 80286 80386 or 80486 family processor and the HIMEM SYS driver or equivalent loaded before installing the mouse driver MS DOS 5 0 systems should also have the line DOS UMB in the CONFIG SYS file Only TABLET COM can be relocated TABLET SYS cannot be relocated You cannot relocate TABLET COM into another memory area without first removing the mouse driver by using the TABLET OFF command Appendix E Configuring AutoCAD Rel 12 for Windows This appendix presumes you are using a template with AutoCAD If you are not using a template you will need to designate a rectangular space within the active area as
39. r detailed template configuration instructions When completed the template mole and tablet areas and toggle button should be properly configured Digitizer Mode vs Mole Mode Your tablet is initially setup in the Digitizer mode In Digitizer mode you can draw in the graphics area execute template picks and operate the cursor buttons However you cannot access the dropdown menus tool palette or manipulate the window this requires the Mole mode To enter in the Mole mode press the button that you previously defined as the Toggle button In Mole mode you can draw in the graphics area execute template picks and access the dropdown menus and the tool palette However the cursor buttons will not have the usual AutoCAD definitions Instead the pick button remains the pick button and the button defined as the toggle button continues as the toggle button All other buttons will produce results that are defined in the Summagraphics Windows control panel 14557 N 82nd St a aA reaa A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 hai SummasSketch III 34 x A CalComp by TURNING technologies Appendix F Interface Power Cable Pin Assignments The table below identifies the pin assignments of the 25 pin D female connector that terminates the interface power cable Refer to this table if you want to use an extension or adapter cable between the interface cable and the computer Pin Wire Name Descriptio
40. s cursor tracking other options NOTE Command options are the same as those running TABLET COM from the DOS prompt or a batch file Most of the command lien arguments described for TABLET COM also work for TABLET SYS The exceptions are the OFF command and the memory location options U E and HI Example For a SummaSketch with a 16 button cursor attached to COM2 DEVICE TABLETMG SYS 2 C16 14557 N 82nd St RIL ESR Co SE 866 746 3015 toll free Scottsdale AZ 85260 wiww gtcocaicomp com 480 998 1751 fax SummaSketch III 17 PN A CalComp by TURNING technologies Summagraphics Utilities Resetting the Tablet MMRST and UIOFRST MMRST Command The MMRST command resets a tablet that is configured for MM SummaSketch format and has a 4 button cursor or stylus attached Command Syntax MMRST options Options Description 7 1 Selects serial port 1 PC XT AT and PS 2 2 Selects serial port 2 PC XT AT and PS 2 3 Selects serial port 3 PS 2 only 4 Selects serial port 4 PS 2 only 5 Selects serial port 5 PS 2 only 6 Selects serial port 6 PS 2 only 7 Selects serial port 7 PS 2 only 8 Selects serial port 8 PS 2 only BAXXXX Selects serial port with a base address of xxxx address must be in hexadecimal N Selects no parity configuration Or H Displays help screen NOTES e When using the BA option Base Address all four digits must be specified Example for COM1 BA03F8 e This pr
41. t for a new configuration NOTE You can also reset the tablet by repowering it e To change default tablet parameters Some applications will only support either the MM Summasketch format or the UIOF Microgrid format For example if you have a tablet configured for MM SummaSketch format and you wish to use an application written for the UIOF Microgrid format you must change the default tablet format from MM to UIOF There are two utilities for changing between the MM and UIOF formats MM COM Utility changes the format of a SummaSketch tablet to MM SummasSketch Use if you have a 16 button cursor attached to the tablet or if the tablet has been previously configured for UIOF Microgrid format UIOF COM Utility changes the format of a SummaSketch tablet to UIOF Microgrid Use if you have a stylus or 4 button cursor attached to the tablet or if the tablet has been previously configured for MM SummasSketch format 14557 N 82nd St a a 866 746 3015 toll free Scottsdale AZ 88260 Www dtcocaicomp com 480 998 1751 fais SummasSketch III 5 PN CalComp by TURNING technologies Installing the SummaSketch III Tablet All cable connections are made at the rear of the SummaSketch tablet Turn off the computer and make sure the tablet power switch is in the OFF position e Insert the small end of the serial cable into the socket labeled I O on the SummasSketch tablet Connect the wide end of the serial cable to the computer s serial co
42. tch Drivers Utilities diskette to override the default tablet formats What are the SummaSketch drivers A Summasketch driver is a program that lets the SummaSketch tablet communicate with your application For the tablet to act as an input device it must be able to communicate with the software A driver converts tablet data into information that can be read understood and used by your application 14557 N 82nd St a aA reaa A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 fax SummasSketch III 4 PN CalComp by TURNING technologies Are there separate drivers for the different tablet formats Drivers are written for specific tablet formats and work with these tablet formats only Be sure to select the proper driver within the application software to match the tablet format What are the SummaSketch Utilities The SummaSketch Utilities allow you to do the following e Reset the tablet without turning the power on and off e Switch between MM and UIOF formats e Test the tablet to ensure that it is working properly When do I need to use the Utilities e To reset the tablet You may need to reset the tablet when switching between some applications Applications configure the tablet for their own needs Using one of the tablet reset utilities MMRST used with tablets configured for MM Summasketch format or UIOFRST used with tablets configured for UIOF Microgrid format clears the table
43. ute screen coordinates or relative mouse units also referred to as mickeys Absolute mode works only with those applications that accept input as absolute screen coordinates To verify that absolute mode is working position the screen pointer and then lift the cursor stylus out of the tablet s active area and place it at a different location on the tablet The screen cursor should snap to a new location If it does not then the application works only in relative mode and the absolute mode option will have no effect Other Options M Overrides an application that changes the mouse cursor for text modes by locking the mouse cursor to the default text cursor To enable locked cursor type M1 disable locked cursor type MO The default is MO N Specifies how many screen updates to skip before actually plotting the cursor This feature is useful for laptop computers and other systems with slower LCD displays A small value is recommended because driver performance can be affected is a number between 0 10 The default is NO NOTES e When selecting a serial port other than 1 2 3 or 4 the BA and I options must be used together 14557 N 82nd St a aA reaa A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 hai SummaSketch III 31 PN A CalComp by TURNING technologies e When using the BA option all four digits must be specified Example for COM1 BAO3F8 e Use the BA and I options
44. ve changes Installing the Protected Mode Driver for AutoCAD Rel 12 1 Copy the protected mode drivers from the Summagraphics Drivers Utilities diskette to the ACAD DRV directory Example COPY A ADIDVR DGPSUMMA EXP C ACAD DRV 2 Startup AutoCAD The AutoCAD Drawing Editor appears on the screen 3 Type CONFIG and press ENTER A listing of the current configuration appears on the screen Select ENTER to proceed to the configuration menu 4 At the configuration menu choose Configure Digitizer AutoCAD asks if you want a new digitizer Since you are installing for the first time type Y and press ENTER A list of digitizer options appear on the screen Select Summagraphics MM Series v 1 3 ADI 4 2 by Summagraphics and press ENTER 5 You are prompted for the size of the tablet Choose the number corresponding to your tablet size and press ENTER 6 You are prompted for the number of buttons on the pointing device stylus or cursor Select the appropriate number and press ENTER 7 You are now asked to name the serial port to which your tablet is connected Type COM7 or COM2 and press ENTER 8 The configuration is now complete and you are ready to use Summagraphics with AutoCAD Exit to the drawing editor and enter Y to save changes Installing the Real Mode Driver for all versions of AutoCAD Copy the file DGSUMMA COM from the Drivers Utilities disk to the hard drive and run the driver before starting Autodesk applications 1
45. yntax TABLETMG com port stylus cursor tracking other options Parameter Permissible Values Description com port 1 default Tablet is connected to serial port 1 of computer 2 Tablet is connected to serial port 2 of computer 3 Tablet is connected to serial port 3 of computer IBM PS 2 only 4 Tablet is connected to serial port 4 of computer IBM PS 2 only a 14557 N 82nd St ee A 866 746 3015 toll free Scottsdale AZ 25260 Wiww gtcocaicomp com 480 998 1751 hai SummaSketch III 16 PN A CalComp by TURNING technologies BAXXXX Selects serial port with a base address of xxxx address must be in hexadecimal x Selects serial port with IRQ line number x 2 7 OFF OFF Disables the driver stylus cursor CP Selects two button stylus C3 Selects three button stylus C4 default Selects four button cursor C16 default Selects 16 button cursor NOTE Refer to Appendix D for TABLETMG COM button mapping tracking and memory location options Example For a SummasSketch with a 16 button cursor attached to COM2 TABLETMG 2 C16 Sample Batch File TABLETMG 2 C16 Installs driver DOSSHELL Runs the DOSSHELL environment Running the driver from CONFIG SYS Another way to install the driver is by including TABLETMG SYS as a device driver in the CONFIG SYS file The system automatically installs the driver each time you boot or turn on the system Line Syntax DEVICE TABLETMG SYS com port stylu
46. your screen pointing range Configuring AutoCAD for Windows 1 Install AutoCAD for Windows as explained in the AutoCAD Installation Guide 2 Startup AutoCAD for Windows In the Drawing Editor select Preferences from the File dropdown menu 3 Inthe Preferences dialog box activate the Save to ACAD N and the Digitizer Mouse Arbitrate radio buttons Click OK to close the dialog box and save changes 14557 N 82nd St a aA reaa A 866 746 3015 toll free Scottsdale AZ 85260 www gtcocaicomp com 480 998 1751 fax SummaSketch III 32 PN CalComp by TURNING technologies Select Configure from the File dropdown menu The current Configuration Screen appears Press ENTER until the Configuration Menu Choose Configure Digitizer from the Configuration Menu AutoCAD asks if you want to select a different digitizer Type Y for yes and then press ENTER Ascreen listing the available digitizer drivers is displayed Select WINTAB Compatible Digitizer ADI 4 2 by Autodesk and press ENTER AutoCAD will display a series of prompts There are an infinite number of possible configurations you can specify at this point Summagraphics recommends using the configuration listed below After you have successfully setup the recommended configuration feel free to try other configurations AutoCAD prompt Response AutoCAD prompt Response AutoCAD prompt Response AutoCAD prompt Response AutoCAD prompt Response Aut