1. 5 o Open Circuit Voltage 21 to 24 VDC o Accuracy 1 of full scale range e Supports custom accelerometers 2 or 3 wires Speed Keyphasor Inputs e Supported Keyphasor transducers include o Proximity probe o Proximity switch o Magnetic Pickup e Supports multiple events per revolution and event ratios for speed inputs up to 20 kHz e Threshold voltage resolution 0 1VDC e Proximity Transducer Interface o Supply Voltage 22 8 to 25 2 VDC o Maximum Rated Current 15 mA o Short Circuit Current 15 1 mA to 23 6 mA o Accuracy 1 of full scale range o Input Impedance 3 wire Voltage Mode 10 KQ o Rpm range 1 to 120 000 e Proximity Switch Interface 10 to 24 VDC 2 75 0 05 V o Supply Voltage o Lower Not Ok limit o Rpm range 1 to 120 000 e Magnetic Pick up o Input voltage up to 125V 250Vp p o Rpm range 200 to 120 000 Contact Inputs Monitor provides the capability of 3 contact inputs with terminals One is used for configuration lock one is for alarm reset function and the 3rd one is used for monitor Alarm Relay Inhibit e Activate Oto 10 kQ e De activate 150 kQ to infinite Button Inputs e External button to reset alarm and relay e One buried button provides 3 functions o Display monitor information including User account Password P address FW HW version o LCD contrast adjustment o Reset settings to default including User account name Password Network configuration Jum
2. 2300 20 Monitor 1 6 ft shielded Ethernet cable 2 Accelerometer sensors 2 4 8M accelerometer cables Excluding keyphasor sensor enclosure and 24 VDC power supply BB Approvals Option None Multiple Explosive Atmosphere Certifications ATEX IECEx We provide 2 kinds of power supplies with different temperature range and different power Please check Accessories in below for Specifications and Ordering Information Part Number 105M0340 01 Rev A 01 15 Page 6 of 10 Accessories Order Information and Graphs 106M7607 01 106M6694 01 105M6193 01 Power supply 110 220 VAC to 24 VDC DIN mount 30W power supply package 25 C 70 C 35X99X95 mm 1 38x3 90x3 74 in Power supply 110 220 VAC to 24 VDC DIN mount 120W power supply package 40 C 70 C 40X130X125 mm 1 57x5 12x4 92 in Fiberglass NEMA 4x IP68 weatherproof housing with window in door includes mounting plate for monitor Dimensions Width x Depth x Height 38 3mM x 389 1mmM x 209 8mm 13 3in x 15 3in x 8 2in FRONT VIEW 13 32 Ue P AM3100T2 Z2 Accelerometer sensor MIL C 5015 2 PIN CONNECTOR 100M0741 Proximity Switch 10 0 METER CABLE Proximity Probes Please refer to proximity probe datasheet 141194 01 for details Specifications and Ordering Information Part Number 105M0340 01 Rev A 01 15 Page 7 of 10 02120015 Bulk Ca
3. 2300 Series Two Channel Vibration Monitors Bently Nevada Asset Condition Monitoring Bently Nevada Asset Condition Monitoring imagination at work Description The 2300 Monitors feature two seismic channels and a speed channel providing continuous monitoring and protection for BOP Balance of plant equipment It is a perfect match for proactively managing your assets rather than waiting until production outages to replace equipment The 2300 series monitors enable condition based monitoring and protection with support for various interfaces and functions Inputs include seismic and speed transducers and outputs include relays buffered output TCP IP Ethernet and an LCD display This monitor is available with either 4 20 mA output 2300 20 or a TrendMaster SPA line interface 2300 25 The 2300 20 Monitor can be used to replace legacy Bently Nevada monitors such as the 1900 27 but more importantly it is a full featured monitor for use in monitoring and protecting assets such as motors pumps and fans The monitor is software configurable and includes configuration software There is also an integrated LCD and multiple LEDs to show the channels real time data and status locally Effective plant asset management and particularly effective fleet management of machinery assets often depends on remote access using condition monitoring software such as System 1 Specifications and Ordering Information Part Numbe
4. ECEx Ex nA nC ic IIC T4 Gc Intrinsic Safety Parameters For Proximitor Transducer Uo 24VDC lo 46mA Co 200nF Lo 1mH For Accelerator Velomitor Transducer Uo 24VDC lo 3 3mA Co 200nF Lo 1mH CSA Canada and U S will be available in April of 2014 For further certification and approvals information visit the following website www ge mcs com bently Physical Dimensions Width x Depth x Height 127mm x 127mm x 76 2mm Sin x 5in x 3in Weight 1 03kg 2 26lbs Mounting Panel mount or DIN rail adapter included Specifications and Ordering Information Part Number 105M0340 01 Rev A 01 15 Page 5 of 10 Ordering Information Two Channel Monitor 2300 20 AA Monitor with 4 20ma Outputs including DIN rail mount assembly manual and monitor configuration software AA Approvals Option 00 None 02 Multiple Explosive Atmosphere Certifications ATEX IECEx 2300 20_KIT AAA BB Bently Nevada 2300 20 Condition Monitoring System Kit AAA Configuration 001 1 2300 20 Monitor 1 6 ft shielded Ethernet cable 1 14x12x8 in fiberglass housing with window 2 Accelerometer sensors 2 4 8M accelerometer cables Excluding keyphasor sensor and 24 VDC power supply 002 1 2300 20Monitor 1 6 ft shielded Ethernet cable 1 14x12x8 in fiberglass housing with window 1 Accelerometer sensor 1 4 8M accelerometer cable Excluding keyphasor sensor and 24VDC power supply 003 1
5. ble from Proximity sensor to monitor 500 feet 9571 AA Low cost cable for accelerometer AA From 20 to 99 Increments of 1 0 foot INCREMENTS OF 1 0 FOOT EXAMPLE 12 FEET 25 FEET MIN LENGTH 2 0 FEET MAX LENGTH 99 FEET 84661 AA Armored cable for accelerometer AA From 30 to 99 Increments of 1 0 foot EXAMPLE 12 FEET 25 FEET 3 0 FEET MIN LENGTH MAX LENGTH 99 FEET CB2W100 AAA Cable for accelerometer AAA 015 15 feet 4 8 m 032 32 feet 9 8 m 064 64 feet 19 5 m 112 112 feet 34 1 m 125 125 feet 38 1 m 150 150 feet 45 7 m 200 200 feet 61 0 m 250 250 feet 76 2 m 286244 Magnetic Mounting base 4 28 threaded hole 105M6203 01 Spare 35mm DIN rail mount and screws included with 2300 20 monitor Ethernet Cables Standard 10 Base T 100 Base TX Shielded Category 5 Cable with RJ 45 connectors solid conductor 138131 AAA AAA Cable Length 006 _ 6 feet 1 8 m 010 10 feet 3 0 m 025 25 feet 7 6 m 040 40 feet 12 2 m 050 50 feet 15 2 m 075 75 feet 22 9 m 085 85 feet 25 9 m 100 100 feet 30 5 m Software 100M9465 01 BN Monitor Configuration SW DVD Version 4 0 or greater DVD including BNMC Configuration Guide User Manual 105M0341 01 Operation and Maintenance Manual Specifications and Ordering Information Part Number 105M0340 01 Rev A 01 15 Page 8 of 10 Graphs and Figures 2 50 119 38 63 50 136 05 T
6. e T communication for configuration using Bently Nevada Monitor Configuration software included e One dedicated speed and Keyphasor channel supporting Proximity probes Magnetic pickup and Proximity switch type sensors e Three buffered transducer outputs including keyphasor signal providing short circuit and EMI protection Buffered outputs for each signal are through BNC connectors e Continuous monitoring and protection e LCD display showing vibration amplitude setpoints and speed e Two acceleration inputs with synchronized sampling for advanced diagnostics e Key measurements Direct 0 pk pk pk True RMS Derived pk integrated direct pk Speed real time provided with alarm configuration e LEDs show the monitor status e Local contacts for positive engagement of channel bypass configuration lockout and reset e Optional Modbus over Ethernet Specifications and Ordering Information Part Number 105M0340 01 Rev A 01 15 Page 2 of 10 Specifications Inputs Outputs Power Input e DC Input 18 36VDC max 7 5W Supports 2 seismic channels e Supports ICP accelerometers o Bandpass variable 0 2 Hz High pass 20 kHz Low pass o Scale Factor range 5 to 1000 mV g o Full scale range 2 to 80 g peak o Bias output voltage 12VDC o Configurable Upper OK limit 0 25 to 22 V greater than lower ok o Configurable Lower OK limit 0 25 to 22 V less than upper ok o Current Sink Source 3 3 mA
7. es if any channel is in alert state o Danger LED engages if any channel is in danger state LCD LCD display allows viewing machine speed vibration levels setpoints and configuration information Communications Ethernet e Ethernet 10Base T and 100Base TxX Conforms to IEEE802 3 e RJ 45 for 10Base T 100Base TxX Ethernet cabling e Cable length 100 meters 328 feet maximum Environmental Limits Operating Temperature e 30 C to 65 C 22 F to 149 F Storage Temperature e 40 C to 85 C 40 F to 185 F Humidity e Up to 95 non condensing Battery Life for Real Time Clock e Powered 38 years 50 C 122 F e Un powered 12 years 50 C 122 F Compliance and Certifications General and Electrical Safety UL Std No 61010 1 3rd Edition CAN CSA C22 2 No 61010 1 12 2006 95 EC Low Voltage Standard EN61010 1 2010 European Community Directives 2006 95 EC Low Voltage EMC Standards EN61000 6 2 Immunity for Industrial Environments EN61000 6 4 Emissions for Industrial Environments EN61326 1 Electrical equipment for measurement control and laboratory use EMC requirements European Community Directives EMC Directive 2004 108 EC Specifications and Ordering Information Part Number 105M0340 01 Rev A 01 15 Page 4 of 10 Hazardous Area Approvals Approval Option 01 CSA Canada and U S Class Division 2 Zone 2 ATEX Il 3G Ex nA nC ic IIC T4 Gc I
8. he monitor must have 2 5 inch clearance on each side for wiring installation Specifications and Ordering Information Part Number 105M0340 01 Rev A 01 15 Page 9 of 10 Wiring Diagram e K Power Input pag Ground Chassis fagas E Jumper Earth Ground Connection LCD Display CHANNEL 1 CHANNEL 2 Recorder Output SPA OUT S S S S S dD S S IS iS XDCR CH1 XDCR CH2 Speed da Buffered Output fj Buffered Output Buffered Output aqa I onitoring Intrinsic Safety Terminals 2300 20 and 2300 25 uses the same interface connector for recorder output or SPA output Denotes a trademark of Bently Nevada Inc a wholly owned subsidiary of General Electric Company 2014 2015 Bently Nevada Inc All rights reserved Printed in USA Uncontrolled when transmitted electronically 1631 Bently Parkway South Minden Nevada USA 89423 Phone 775 782 3611 Fax 775 215 2873 www ge mcs com bently Specifications and Ordering Information Part Number 105M0340 01 Rev A 01 15 Page 10 of 10
9. per between COM amp Chassis GND e There is a 2 pin terminal interface which allows connection of COM and Chassis GND together e Alternatively COM can be connected to earth ground separately through a terminal Buffered Output e There are three buffered outputs available on the monitor through BNC connectors Relay Output e There are two dry contact relay outputs e May be normally energized or de energized e Relay circuit specification o Type Single pole double throw Specifications and Ordering Information Part Number 105M0340 01 Rev A 01 15 Page 3 of 10 o Sealing Epoxy sealed o Contact life 100 000 cycles 5 amps 250 VAC 200 000 1 amp 24 VDC o Insulation resistance 1000 MQ minimum 500 VDC o Relay closed contact resistance 1 Q maximum o Relay open contact resistance 1 MQ minimum o Maximum switched contact voltage 400V AC 150V DC o Maximum breaking contact current 6A 250VAC 6A 24VDC o Maximum switched power 1500VA AC 150 Watts DC LEDs e OK Indicates when the monitor is operating properly e Protection fault indicates a problem with the system preventing normal operation e User inhibit indicates the relays have been intentionally inhibited from operation e Relay status indicates if relays have been activated e TX RX Indicates the Ethernet status and monitor communicating with remote software e Speed channel status e Channel Alarm Status o Alert LED engag
10. r 105M0340 01 Rev A 01 15 Page 1 of 10 Monitor Key Features 2300 20 e Two 4 20mA outputs e Two relay outputs with programmable setpoints e Ethernet 10 100 Base T communication for configuration using Bently Nevada Monitor Configuration software included e One dedicated speed and Keyphasor channel supporting Proximity probes Magnetic pickup and Proximity switch type sensors e Three buffered transducer outputs including keyphasor signal providing short circuit and EMI protection Buffered outputs for each signal are through BNC connectors e Continuous monitoring and protection e LCD display showing vibration amplitude setpoints and speed e Two acceleration inputs with synchronized sampling for advanced diagnostics e Key measurements Direct 0 pk pk pk True RMS Derived pk integrated direct pk Speed real time provided with alarm configuration e LEDs show the monitor status e Local contacts for positive engagement of channel bypass configuration lockout and reset e Optional Modbus over Ethernet Recommend for Demonstration Kit 2300 20_KIT 003 e 1 2300 20 Monitor e 1 6 ft shielded Ethernet cable e 2 Accelerometer sensors e 2 48M accelerometer cables To be ordered separately 106M7607 01 Power supply 110 220 VAC to 24 VDC DIN mount 30W power supply package 25 C 70 C 2300 25 e Trendmaster SPA interface e Two relay outputs with programmable setpoints e Ethernet 10 100 Bas