1. signal repeater of DIS the left turn to the first and the third digits of code the right turn to the second digit of code and by a LED blink To confirm enter of a digit press and release the brake pedal DIS flashes one time by the both repeaters simultaneously When the third digit is entered module check the code for validity and confirm it by repeaters flash twice by the both repeaters simultaneously in the case of valid code flash twice by the both repeaters alternately in the case of invalid code and by a LED goes off once a second twice in the case of valid code goes off for 2 seconds in the case of invalid code If you made a mistake with the number of button presses when you enter the code press and release the brake pedal until the module indicate an error by repeaters Enter the code again in that case Also you may enter other codes without exit of programming mode Release a brake pedal and turn the ignition off to exit programming mode New settings will be saved in the module s memory and will be stored there regardless of whether the module is connected or not Attention If you start the engine without exit of programming mode new settings will not be saved in memory To reset the module to factory settings enter the code 8 1 1 Both repeaters will flash three times to confirm command execution and then the module will exit of programming mode and will restart To clear all the errors in the heater s memory and thus
2. two connectors 9 pin connector XI table 1 for input signals and povver connection 10 pin connector X2 table 2 for output signals special signals and CAN bus connection The first pin on each connector is marked by the key Table 1 XI pin Signal Name Polarity Wire colour number Heater off White Heater off Grey Heater on Green Heater on Blue Button Brown Timer in Orange RC in Yellow Ground Black Battery Power Red The signals to be necessarily connected marked in the table by Italics RO OO NI ON AI wN IR Table 2 X2 pin Signal Name Polarity Wire colour Maximum number Electric Load mA RC out Blue vvhite Heater Status Yellow Alert 1 Grey Alert 2 Orange Engine RS Blue Indication Red white Sensor In Green yellow Sensor Out Green CAN L Brown white CAN H Brown 1 2 3 4 3 6 7 8 9 1 The connection of outputs 2 5 directly to the Power without a load is not permitted The connection of outputs 1 and 6 directly to the Ground without a load is not permitted The signals to be necessarily connected marked in the table by Italics X1 1 Heater off The input can be used to svvitch off the heater operated in pre heat mode by the impulse of positive polarity the input Heater_off in that case has to be connected to the Ground The heater is stopped by the leading edge of the impulse If the heater is idle positive impulse on this input canc
3. unblock the heater enter the code 9 1 1 Both repeaters vvill flash five times to confirm command execution If unblocking of the heater is impossible the repeaters will flash five times alternatively Pay attention when you apply unblocking function for the first time RCP Can remember VIN code of the car In the future unblock function will work only for this car Settings Table 4 2 2 1 Limitation of 2 1 1 Not applied Heater heater s total 2 1 2 40 minutes Timing operation time in 2 1 3 50 minutes pre heat mode 2 1 4 60 minutes 2 1 5 70 minutes 2 1 6 80 minutes 2 1 7 90 minutes 2 1 8 100 minutes 9 2 1 9 120 minutes 2 2 Limitation of heater s cycle operation time in pre heat mode 2 2 1 10 minutes 2 2 2 15 minutes 2 2 3 20 minutes 2 2 4 25 minutes 2 2 5 30 minutes 3 3 1 Unlock 3 1 1 Heater start only Heater button function for 3 1 2 Start of idle heater stop of operated remote the heater control heater control by 3 2 Unlock 3 2 1 Heater control by Ford key is disabled Ford Key button presses count 3 2 2 Two presses to start the heater 3 2 3 Three presses 3 2 4 Four presses 3 2 5 Five presses 3 2 6 Six presses 4 4 1 4 1 1 Not adjusted Battery Minimal voltage to 4 1 2 11 4V Monitoring let the heater start 4 1 3 11 6V in pre heat mode 4 1 4 11 8V 4 1 5 12 0V 4 1 6 12 1V 4 1 7 12 2V 4 1 8 12 3V 4 1 9 12 4V 4 2 4 2 1 Not adjuste
4. 1 second duration appears on the output By default the signal Heater stopped is given on the output X2 5 Engine RS Not used X2 6 Indication The output can be used for connection of stand alone or button built in indicator which will inform you about heater run time errors X2 7 Sensor In Not used X2 8 Sensor Out Not used X2 9 CAN L Low level line of Medium Speed CAN bus X2 10 CAN H High level of Medium Speed CAN bus Connection RCP Can has two variants of connection Plug n play connection is easy type of connection which not requires special skills Permanent connection is recommended for professional installation It needs at least some experience in car electronics installation Read installation manual for detailed connection schemes Basic Functions 1 To start stop the heater by additional remote control see documentation for the remote control The functions of the remote control depend on its possibilities connection schemes and module s settings 2 To start the heater by the original Ford key press Unlock button 3 times and then press Lock button Time intervals between presses must not exceed 20 seconds The excess of time interval will restart the counter of Unlock button presses Watch to the turn signals to be sure that RCP has received a command from the key every Unlock button press on the key will be confirmed with long single flash of hazard flashers Lock button pr
5. 5 Signals on the output Status 7 5 1 Heater operates potential 7 5 2 Heater operates autonomously from battery engine is off potential 7 5 3 Hazard flashers control double impulses with the frequency adjusted by 6 7 applying settings 6 1 6 5 7 5 4 Engine runs potential 7 5 5 Engine runs RPM impulses 7 5 6 Ventilation is on during the heater operation potential 7 5 7 Ventilation is off during the heater operation potential 7 5 10 Disable the output 7 6 Signal feed to the output Status Plus 7 6 1 Heater operates potential 7 6 2 Heater operates autonomously from battery engine is off potential 7 6 3 Feedback for Defa Vehicle Unit 11 7 6 4 Engine runs potential 7 6 5 Ventilation is on during the heater operation potential 7 6 6 Disable the output 8 8 1 1 Apply factory settings Settings reset 9 9 1 1 Clear all errors in heater s memory Heater errors resulting heater unblocking reset Factory setting Recommended settings is marked in italics 7 RCP will turn off the heater if the battery voltage becomes lower than presetted _ Setting is not tested yet Signals appear only at the heater autonomous operation Signal is used for indication by the hazard flashers It uses 1 wire connection to the hazard alarm button see installation manual for details Additional connections required see installation manual not
6. RCP Can FTC Version 7 2 Technical description User manual Rev A Table of Contents DESI HOR gerents nina nee moe materials 2 Module POSSIbIHHES SEE Mn ne a RSR SR EN 2 PACRASE Contenen mant Gats aten esgotat peca ann 2 EU LE OT ted codes ela ES Gaia Dei Ceres 3 ONCE OM es ors Dema be es edad En RS dE IO ESA os 6 BASIC FUNCHON Sat tal ea tt let altes tat detecta M 6 Additional Functions sua GC a o De ea Lla 7 TROUDIESHOGUING it bi ses ates escates tapat atacs 12 COS AN TR care mente ser here a aaa 14 Description The RCP Can FM module is intended for remote control connection to the fuel fired heater parking heater fuel operated heater pre heater which was factory equipped on Ford Transit Custom 2013 and Ford Tourneo Custom 2013 including the original Ford vehicle key The device controls the heater via CAN bus Module Possibilities e The heater start and stop by various impulses e Heater status signals e Embedded remote control of the heater by the original 3 button Ford vehicle key e Remote cancellation of the heater start programmed by the driver information system e Extended boost heat mode control e Main battery protection from discharging by inspection of the voltage level and time of autonomous work of the heater e Heater errors clearing unblocking Package Content RCP Can FM module VViring for permanent connection Plug n play cable Manuals BS D Signals The module has
7. d Minimal voltage to 4 2 2 10 6V keep operating the 4 2 3 10 8V heater for pre heat 4 2 4 11 0V mode 4 2 5 11 2V 4 2 6 11 4V 4 2 7 11 5V 4 2 8 11 6V 4 2 9 11 7 V 6 6 1 Indication of 6 1 1 Off Heater command reception 6 1 2 Three flashes startup and from remote operation control mode 6 2 Indication of 6 2 1 Off indication by successful startup of 6 2 2 Seven flashes the turn the heater via signals remote control 6 3 Indication of the operated heater started by remote 6 3 1 Off 6 3 2 On 10 control 6 4 Indication of 6 4 1 Off the operated heater 6 4 2 On started by DIS direct or program start 6 5 Indication of 6 5 1 Off the operated heater 6 5 2 On started by additional button 6 7 Flashing 6 7 1 One flash within 3 sec frequency for indication of heater autonomous operation 6 7 2 One flash vvithin 5 sec 6 7 3 One flash within 10 sec 6 7 4 One flash within 15 sec T Output signals adjustment 7 3 Notification signals on the output Alert 1 7 4 Notification signals on the output Alert 2 7 3 1 Heater started 7 3 2 Heater stopped 7 3 5 Heater started to burn 7 3 6 Heating finished 7 3 7 Error occured 7 3 8 Disable the output 7 4 1 Heater started 7 4 2 Heater stopped 7 4 5 Heater started to burn 7 4 6 Heating finished 7 4 7 Error occured 7 4 8 Disable the output 7
8. els the program start of the heater programmed by DIS X1 2 Heater_off The input can be used to switch off the heater operated in pre heat mode by the impulse of negative polarity the input Heater_off in that case has to be connected to the Power The heater is stopped by the leading edge of the impulse If the heater is idle negative impulse on this input cancels the program start of the heater programmed by DIS This input is suitable for the most alarm systems and GSM modules connections in order to control the heater remotely X1 3 Heater ont The input can be used to svvitch the heater on by the impulse of positive polarity the input Heater on in that case has to be connected to the Ground The heater is started by the leading edge of the impulse X1 4 Heater on The input can be used to svvitch the heater on by the impulse of negative polarity the input Heater on in that case has to be connected to the Power The heater is started by the leading edge of the impulse This input is suitable for the most alarm systems and GSM modules connections in order to control the heater remotely X1 5 Button The input for outer multi functional button connection The current function of the button depends on the heater status the ignition status and the engine status see Table 4 for more details X1 6 Timer in Not used in current version X1 7RC in The input can be used to switch the heater on off by an impulse of positive po
9. ess on the key will be confirmed with short double flashes of hazard flashers 3 The RCP Can is adjusted by default only to switch the heater on by Ford key If you also plan to switch off the heater too change the setting 3 1 As both the commands use the same combination of Unlock presses you should know a condition of the heater before a command send The possibility to stop the heater remotely may be useful in the case of cancelation of the trip including ones programmed by DIS 4 You can remotely cancel the start of the heater by a DIS program if your additional remote control can send stop command when the heater is idle not possible by Ford key After stop command sending DIS programs will be temporary disabled Starting the heater by any way or turning the ignition on will enable DIS programs again 5 Additionally installed button has several functions Current function is defined by the heater condition the ignition condition and the engine condition see table 3 When the ignition is turned off the button is used for immediate start or stop of the heater Button press changes a heater condition to another one switches off the operated heater or switches on the idle heater When the ignition is turned on button press keeps the current condition of the heater after the engine start So if the heater has operated before the engine start it may continue to operate after the engine start in boost heat mode If the heate
10. larity The heater is turned on by the leading edge of an impulse and is turned off by the trailing edge of the impulse The specialized remotes such as Smart Start Easy Start and Telestart can be connected to this input GSM modules with a potential signal on the control channel also may be connected to the input X1 8 Ground X1 9 Power 12V X2 1 RC out Signal is used for RCP DSS Rit version only The input is used to inform the remote control unit that the heater has been switched off When the heater is switched off the impulse of positive polarity with 0 5 second duration appears on the output When the engine is running the output is permanently pulled up to the Power X2 2 Status The assignment of this output is defined by the setting 7 5 By default the signal Heater operates autonomously is given on the output X2 3 Alert 1 The signal is used to receive a notification to remote control if remote is compatible to alerts receiving The assignment of this output is defined by the setting 7 3 When programmed event is occurred the impulse of negative polarity with 1 second duration appears on the output By default the signal Heater started is given on the output X2 4 Alert 2 The signal is used to receive a notification to remote control if remote is compatible to alerts receiving The assignment of this output is defined by the setting 7 4 When programmed event is occurred the impulse of negative polarity with
11. ne battery voltage at the to charge or cancel 4 1 4 2 heater startup or during module s settings the heater operation is below the specified settings 4 1 n 4 2 4 Time limits Time limit for Run the engine It is exceeded autonomous operation of recommended to have trips the heater is achieved between heater operation cycles with active setting 2 1 2 longer than heater operation 2 1 9 cycles 5 Unsuccess The heater switched off Make a diagnostics of the heater ful start spontaneously at startup if the error is repeated 6 Operation The heater was switched Make a diagnostics of the heater cycle too off spontaneously with if the error is repeated short operating time of less than 20 minutes 8 CAN bus There is a problem with Check the module connection error connection of the module to the CAN bus 9 Settings Settings have been Reset the settings 8 1 1 error incorrectly stored in readjust RCP RCP memory 11 Heater no The heater is unplugged Make a diagnostics of the heater connection from CAN bus or is out of order Autoplugin ES www autoplugin ru
12. ou enable boost heat mode again Additional Functions By default RCP Can is adjusted to execute basic functions such as a start of the heater by the Ford key or by additional button a stop of the heater by the button and a control of the boost heat mode by the button To turn on additional functions a possibility to stop the heater by Ford key battery monitoring indication by the turn signals in the rear view mirrors extended control of boost heat mode etc you may enter the module into programming mode and activate the corresponding setting Programming button and the brake pedal are used to enter programming mode and to the settings change Plug n play cable is equipped with preinstalled 8 programming button Use additionally installed button as programming button in the case of permanent connection of the module It is necessary to stop the engine and the heater before Turn the ignition on press and hold the brake pedal Then press and release 3 times programming button hold additional button every time until LED is not goes off about 1 5 seconds Both turn signal repeaters in DIS will flash twice LED goes on as a confirmation of entering programming mode Release the brake pedal now Each setting in the table 1 corresponds to the 3 digit code You need to enter appropriate code to activate a setting To enter a digit of a code press the button so much times as corresponds to a digit Each button press is confirmed by a turn
13. r has been idle before the engine start button press will inform RCP don t let the heater to start in boost heat mode after the engine 7 start These functions are called quick enabling and disabling of boost heat mode respectively Being activated these functions act for the current ignition cycle Turning the ignition off cancels function activity When the engine runs the button press is used to quick enable of the boost heat mode if boost heat mode was disabled Warning The parking heater must not be operated at filling stations near sources of combustible vapours or dust or in enclosed spaces Table 3 status status status how to use Heater immediate Not running One touch heater start start Heater immediate Not running One touch heater stop stop One time boost Not running Quick disabling of boost disable heat mode for short trips One time boost Not running Quick enabling of boost enable heat mode in the case of boost heat mode disabling Running by RCP settings or in the case of one time disabling previousiy The fuel fired heater needs about 3 minutes to go to the normal operation after the startup If your trip is planned to be shorter it is highly recommended to use a button function called one time boost disable This preserves the heater from premature clogging Turn on the ignition press the button then start the engine Now the heater will not operate with the engine while don t y
14. via plug n play cable 7 Ford key only Troubleshooting If a run time error occurs at the start of the heater RCP Can will inform you by the built in and additional LEDs blinking about the error code The number of flashes corresponds to the error code See table 5 for the codes description and possible solutions Table 5 Error Error Possible Reasons of Solutions Code Description Error Appearance 1 Start error Fuel level in the tank is Refuel the vehicle close to empty 2 No answer Outer temperature is The heater works only with from the upper than 15 Celsius temperatures below 15 C It is heater degrees the heater manufacturer s followed restriction the start command The engine 1s hot no Let the engine cool down below need to pre heat 75 degrees 12 The heater hasn t finished previous cycle of operation yet you can hear the noise from the air blower fan The heater will startup after previous cycle of operation will be fully completed The heater is blocked after 5 unsuccessful starts Try to start the heater from DIS menu If it not started to burn check for fuel and coolant quality especially at extreme cold temperatures and possible heater s exhaust system clogging by snow Then unblock the heater by RCP command 9 1 1 3 Battery The module has Charge vehicle s battery with level is low determined that the special charger or start engi