1. it with corrosive substances Hydrochloric acid If high melting grease is used melt it separately before putting into the tank It is advisable to clean the food residues in tank promptly everyday Cool the oil to room temperature before cleaning the tank or draining off the used oil If the oil is lower than the MIN level refill to the tank promptly Do not modify the air inlet required for combustion If not going to use the appliance at any time cut off the gas supply If not going to use the appliance for a long period of time clean the furnace surfaces with a gasoline cloth and store it in a well ventilated area General inspection should be carried out at least once a year by professional personnel 90 of the appliance is made of metal stainless steel iron aluminum galvanized metal sheet which can be recycled by appointed treatment plant according to the environmental standards of the equipment installed countries in force No littering 8 Failure Analysis amp Trouble Shooting Symptoms Causes The pulse igniter does not work 2 Plug of igniter gets off or the ceramic needle of the pilot is damaged 3 Pressure in the gas pipeline is not enough The pilot nozzle is blocked Connection of thermocouple is incorrect or the Temp limiter is disconnected 6 The thermocouple is defective due to the pilot heating Gas thermostatic valve is defective The pilot flame cannot be lit up Pressure in the gas p
2. 5 16 Installation initial use and maintenance should be done by professional or licensed personnel or franchised person approved by manufacturer Please keep the integrity of the appliance and remove the outer packaging If you do have any questions call the specialist and stop using the appliance To avoid danger keep the packing materials away from children For the materials are plastic bags nails etc For initial use the duration of ignition may be a little longer due to the air existing in the new pipeline If it cannot be lit up for the first time turn the ignition switch off and turn it on 3 minutes later to prevent from deflagration To avoid hazard turn the appliance off if not going to used it or if it is unattended This product is only for commercial use not suitable for other uses or it may cause danger This appliance is only designed for food frying not applicable for other uses Do not sway or tilt the appliance during operation Do not dismantle or self modify the appliance Dismantlement and self modification may cause casualty Do not pat the product or put any heavy objects onto it Do not place any objects in the vent of the gas heater Obstruction of smoke exhaustion may do harm to health Abnormal operation may lead to appliance damage and danger High temperature may cause scald Do not touch the appliance directly with hands due to high temperature during or after operation Do not destroy the contro
3. C 7GFR1211 C9GFR1211 C7GFR2421 C9GFR2421 Gas Fryer with Cabinet Luxury Gas Range Series User s Manual Dear Client amp User Firstly thanks for purchasing and using our product All the information and guidelines of this user s manual comply with certain applicable regulations which come out from our long term accumulated knowledge and experience as well as current project development situations Limited to some special structures additional specified items or new technology changes the actual usage situation might be some different from what stated in this user s manual Should you have any question please do not hesitate to contact the manufacturer via the method shown in back cover page of this manual For safety purpose and efficient operation please make this document available to users for reference Do have them to read this manual carefully before carry out any action on this device especially when starting The manufacturer declines any responsibility in the event users do not follow the instructions or guidelines stated here The user s manual should be placed close to the device in convenience of users reading before operation We have the full authority to reserve the further technical changes of the device in the scope of further performance improvement characteristic development J Warning Any self modification wrong installation adjustment or maintenance can lead to property loss or casual
4. Regulating the Air Inlet see chart below In principle the damper should be the MAX which should be regulated if the flame is unstable or combustion is incomplete Adjustment should be done by professional technicians nd 6 Routine Inspection It is necessary to check the machine daily Check the machine regularly can avoid serious accident happens Stop using if user feels that there are some problems in the circuit or machine Check the situation of the machine before or after using every day Before using Whether the machine is tilted Whether the control panel is damaged During using Whether there is strange odor or vibration noise Whether the burner flame is normal Any light back or flameout Whether the power is normal 7 1 oO aN w 11 Cleaning amp Maintenance Before using clean the tank and basket s to remove all the commercial grease Cleaning can be carried out as follows Fill the tank with water add some detergent and boil for a few minutes When it reaches 40 50 degrees clean the grease in tank with a towel Do not clean the tank with abrasive detergent neither does scrape the surface with steel wire brush or sharp utensil After cleaning drain out the dirty water from the tap Then rinse the tank with clear water Do not aim at the appliance surface with water directly neither does clean
5. ipeline is not enough The main nozzle is blocked The gas switch is defective The pilot flame is on but the The thermostat is defective or connection is main burner cannot be lit up loose 5 Terminals of thermocouple and valve are in bad contact 6 The thermocouple is defective PON SIN Aforementioned troubles are just for reference If any failure occurs please stop using and inform the professional technicians to check and repair Safety is first and maintenance should be done after shutting down the power supply and gas supply
6. l panel with hard or sharp objects Do not aim at the appliance with water jet during cleaning To prevent surface oxidation and chemical interaction the stainless steel surfaces should be cleaned appropriately and regularly This appliance is verified by laboratory satisfactory performance is guaranteed To save energy please avoid operating the appliance in circumstance of not cooking food or in bad performance Working Instructions amp Operation Flow Do not operate the appliance if there is no oil or grease in tank Oil or grease for frying should be substituted regularly Oil used more than once may produce impurity lower the fire point and increase the possibility of sudden boiling Hot oil splashing may occur if large amount of food is non oily If oil burning occurs turn off the gas switch immediately and cover the lid 5 1 Control Panel A thermostat knob B ignition switch C igniter D Temp limiter E Temp control gauge F flame failure switch D E C o 120 C 132 C r e iar l 7 165 C Fa x 123 C eX 190 C 4 20 C ay 5 2 Ignition Special Note For initial operation duration of ignition may be a little longer due to the air existing in the new pipeline Turn the thermostat knob from A to 0 position Press down the ignition switch B Hold it Press igniter C till the pilot flame is lit
7. ly applicable to low pressure gas regulating valve It may cause property loss or safety accidents if high or medium pressure regulating valve is used Do not dry heat the appliance Fire warning If you smell the gas please keep away from any fire source Do not light up any device or touch the electronic switch Do not use any phone in the building either Close the main gas valve immediately and call the professional personnel to maintain it Operate by force or maintain improperly will lead to large gas leakage or deflagration easily The manufacturer won t bear any responsibility for fire hazard caused by improper operation or maintenance Contents Functional Introductoninco it hess dates ae leleeteectdess 1 Structure Schematic Diagram ssssesserserresrerrrerrerrrene 1 Basic Features amp ParametelrS cccceceeeeeeeeeeeeeeeaees 3 Precautions amp Recommendations 6 cceeeeeeeeeeees 4 Working Instructions amp Operation FIOW cee 6 FOULING INSDMOCIOMN nssr renea EEE 9 Cleaning amp Maintenance s essseeseseerrresrrrrrerrrrrsrrrrree 10 Failure Analysis amp Trouble Shooting cccceceeee 11 1 Functional Introduction This product is manufactured by our company which is combined with advantages from home and abroad It is novel in design reasonable in structure easy in operation durable in using and convenient in maintenance Therefore it is the ideal equipment for ho
8. side The packaged machine should be stored in a ventilated warehouse without corrosive gas If it needs to be stored in open air temporarily measurement against raining is needed 4 2 Notice for Installment 1 Installation should be done by professional technician 2 Take out the attached battery turn the pulse button counterclockwise then put in the battery in the correct direction as shown and tighten the pulse button 3 Appliance connection should conform to provisions in gas safety installation and operation 4 The appliance should be installed separately or assembled with other devices in accordance with provisions 5 The appliance is not suitable for built in installation 6 The appliance should keep a minimum clearance of 10cm away from non combustible substance e g walls windows etc on both sides and 20cm at its back Do not install the appliance on flammable floor or materials 7 During installation please consider the weight of the appliance It is advisable to install on the floor 10 Do not use gas that not applicable to the appliance as fuel neither does high pressure 11 12 13 14 15 16 17 18 The appliance should be installed in a well ventilated area if possible under a vent hood in compliance with all applicable regulations in force This will ensure that all burnt gases produced during the combustion process are completely exhausted After installation keep the appliance s
9. table and level Do not tilt or sway during operation Before installation remove the outer plastic films or medium pressure regulating valve This appliance is only applicable to low pressure regulating valve Before installation a quick acting disconnecting valve should be installed upstream the appliance where is easy to reach Making sure the applicable gas is the same as the supplied one If not stop using Pipeline connected to the appliance should be connected with proper metal pipe If the pressure of the gas pipeline is 10 higher or lower than the rated pressure the appliance required a regulator should be installed to ensure it reaches the rated value After connecting the appliance to the gas system check for leaks at joints and pipe fittings to do so use soapy water or a specific leak detector spray No Flaming Check the gas supply pressure after installation Gas supply pressure can be measured with a liquid filled pressure gauge e g a U shaped pressure gauge minimum scale division 0 1mbar or a digital gauge Procedure as follows Remove the panel unscrew the screw on the pressure port Picture 2 Place the pressure gauge Start up the appliance by following the instructions in the user s manual Check the supply pressure After the check remove the pressure gauge Replace the sealing screw sealing screw pressure port Picture 2 4 3 Special Notice 1 10 11 12 13 14 1
10. tel supermarket restaurant western restaurant fast food restaurant and food industry 2 Structure Schematic Diagram Structure Schematic Diagram C7GFR1211 C7GFR2421 dd C9GFR1211 u C9GFR2421 3 Basic Features amp Parameters Model C9GFR1211 C9GFR2421 C7GFR1211 C7GFR2421 Dimension mm 400 900 go0x900x950 60 360 700 299700850460 850 60 850 60 Thermal Power kW 15 5 15 5x2 15 5 15 5xX2 LPG 15 5 15 5X2 15 5 15 5X2 Power N 15 5 15 5X2 15 15 5X2 a G 55 5 5 5 5 TG 17 8 17 8X2 17 8 17 8X2 LPG 1 23kg h 1 23kg hx2 1 23kg h 1 23kg hx2 G a NG 1 56M h 1 56M hx2 1 56M h 1 56M hx2 Cons TG 3 83M h 3 83M hx2 3 83M h 3 83M hx2 Capacity L 20 2 20 2 20 2 20 2 20 2 20 2 Basket 1 2 1 2 Nozzle Table Gas Type Nozzle Diameter NG 2000 Pa 91 8 LPG 2800 Pa 91 15 Town Gas 1000 Pa 04 0 Note When replacing requirements in the aforementioned table must be observed If unlisted gas is used please contact the manufacturer or supplier directly Substitution should be done by professional personnel 4 Precautions amp Recommendations 4 1 Transportation and Storage During transportation the machine should be carefully handled and do not put it upside down to prevent from damaging to the shell and in
11. ty Please contact the manufacturer for any adjustment or maintenance and have the work done by a trained amp qualified person For your safety sake please keep the machine away from any liquid gas or other object which is flammable or explosive This appliance should not be operated by those who have physiological perceptual or mental disabilities or those who have insufficient experience or knowledge including children Only in conditions of being given sufficient supervise amp guarantee of personal safety as well as proper instructions amp guidance those who were mentioned above can make some particular operation of this device Keep children away from the device Preserve this manual safely When passing on selling the device to a third party the manuals must be handed over along with the device All users must operate the device complying with the user s manual and related safety guidelines If this appliance is placed near walls partitions or kitchen furniture and the like it is advisable to make these facilities with non combustible material otherwise cover them with non combustible heat resistant material and pay attention to fire prevention regulations The appliance should be installed in a well ventilated area if possible under a vent hood in compliance with all applicable regulations in force This will ensure that all burnt gases produced during the combustion process are completely exhausted The appliance is on
12. up if it is a pulse igniter just press it it can ignite automatically then hold pressing switch B for no less than 20s Release switch B If the flame is failure repeat the aforementioned operations Rotate knob A to desired temperature in accordance with the temperature list in the table 5 3 Temperature Control When the designated temperature is reached the main burner will go off automatically and the main gas supply will turned off automatically to keep constant When the temperature drops to designated temperature 10 C the main burner will start working automatically to adjust the temperature The appliance will repeat the work aforementioned automatically 5 4 Flameout Activate the flame failure switch F to turn off all the source of ignition Turn off the main gas supply Special Note If the source of ignition needs restarting immediately after flameout it must be ignited 1min later than the turnoff of switch F 5 5 Replacing the Nozzle see chart below The following operations should be done by professional personnel or franchised person Remove the pilot nozzle on B Remove nozzle D Substitute with a main nozzle and pilot nozzle matched with the gas supply Tighten the nozzle and attach a new label to specify the new gas type yi ee B aa J A burner bs B pilot kindling Hoper oa C air regulator ji e D nozzle ag WA eo E nozzle base U j F F shunt tube 5 6

Download Pdf Manuals

image

Related Search

Related Contents

Oki C6100dn User's Manual  PS-412PIR Detector de Movimento PIR MANUAL DE INSTALAÇÃO  Samsung SGH-D900I User Manual  MANUAL DE INSTRUCCIONES MOTOR A GASOLINA  Continental Refrigerator SW27-FB User's Manual  【LEON MBシリーズ】 取扱説明書  Kenroy Home 32448ABRD Instructions / Assembly  (Microsoft PowerPoint - FT-Airwick M\350ches eaux fraiches  