Home

Thank you for selecting our product LX-SI-108A

image

Contents

1. M FOR ADDITIONAL PROTECTION a INSTALLATION 1 According the triangle mark open the unit 2 Hold the smoke alarm base against the ceiling or wall and make a mark at the center of each of the mounting slots with a pencil 3 Place the unit where it won t get covered with dust when you drill the mounting holes Using a 6 5mm drill bit drill a hole through each pencil mark into 35mm deep 4 Insert the plastic screw anchors into the holes and tap them gently with a hammer Tighten the 3 30 screws into the screw anchors then loosen them two turns 5 Slide the smoke alarm base up to the screw heads end up in the narrow ends of the mounting slots see the right diagram then tighten the screws completely 6 Insert the 9V battery into the box 7 Close the cover with the alarm and then finish your installation TEST It is important to test this unit weekly to make sure it is working properly Don t open the alarms by yourself return them to the seller if improperly and don t use fire to test your alarms 1 Press and hold the test button on the cover of the unit until the alarm sounds If it does not alarm make sure that the unit is receiving power and test it again If it still does not alarm replace it immediately or check your battery 2 The signal flashes once 30 seconds and while it alarms the signal will flash once 0 5 second 3 If the alarm makes low chirp sounds every about 30secon
2. Stand Alone Smoke Alarms LX SI 108A Thank you for selecting our product LX SI 108A LX SI 108A Optical Smoke Alarm User s Manual LX108A are optical smoke alarms they are generally more effective at detecting smoldering fires which smolder for hours before bursting into flame Sources of these fires may include cigarettes burning in couches orbedding IMPORTANT PLEASE READ CAREFULLY AND KEEP IT This user s manual contains important information about your smoke alarm s operation To insure your safety you need install one alarm at least in your every single room Please don t open the smoke alarm for that may cause improper effect If you are installing this smoke alarm for use by others you must leave this manual or a copy of it with the end user TECHNICAL PARAMETER Power DC9V Low Voltage Alarm 6 5V 7 5V Static Current lt 10uA Alarm sonority gt 85 db 3m Alarm Current lt 12mA Working temperature 10 50 C WHERE TO INSTALL SMOKE ALARMS 1 At first you need install them in your bedroom and routeway and should install one item in every bedroom at least 2 Stairway is important for you to rush out when fires occur so there must install smoke detectors 3 You at least require one smoke alarm on every floor including finished attics and basements 4 Install one alarm beside every electric facility 5 Install smoke alarms in the middle of ceiling because smog heat and flashes always
3. ds it tells you to exchange your battery 4 Little smoke will not cause alarms so misinformation occurs only when you blow smoke to the alarms directly or you forget to turn on your ventilated facility while your cooking 5 Sometimes when you smoke the unit will alarm so you can just blow air to it to stop alarming www lexing com cn cm Stand Alone Smoke Alarms LX SI 108A REGULAR MAINTENANCE 1 Never use water cleaners or solvents to clean your smoke alarm since they may damage the unit 2 Test it at least once a week 3 Clean the smoke alarm at least once a month Gently vacuum off any dust using your household vacuum s soft brush attachment Open the cover and disconnect the battery gently vacuum the inside of the cover and the sensor chamber reconnect the battery close the smoke alarm and vacuum the outside of the cover test the smoke alarm 4 Use these batteries to replace the old one Carbon zinc EVEREADY 216 OR 2122 GOLDPEAK 1604P OR 1604S Alkaline EVEREADY 522 DURACELL MN1604 MS1604 GOLDPEAK 1604A Lithium ULTRALIFE U9VL 5 You d better use good battery to make the alarm work long some batteries can use more than 1 year LIMITATIONS OF SMOKE ALARMS 1 United States NFPA72 tells that the safety of life is to be noticed by alarms before fire to confirm the correct escape way The fire systems help half of residents escape and we should help the old people women and children more because they are always the
4. e into the sensing chamber of a smoke alarm near the kitchen 3 In very damp humid or steamy areas or directly near bathrooms whith showers Keep units at least 3m away from showers saunas dishwhashers etc 4 Where the temperatures are regularly below 40 F 4 C or above 100F 38 C including unheated buildings outdoor rooms porches or unfinished attics or basements 5 In very dusty dirty or greasy areas Don t install a smoke alarm directly over the stove or range Clean a laundry room unit frequently to keep it free of dust or lint 6 Near fresh air vents ceiling fans or in very drafty areas Drafts can blow smoke away from the unit preventing it from reaching the sensing chamber 7 In insect infested areas Insects can clog openings to the sensing chamber and cause unwanted alarms 8 Less than 305mm away from fluorescent lights Electrical noise can interfere with the sensor 9 In dead air space for example in Diagram 1 near the corner less than 10cm 10 If you have a smoking meeting room don t install the alarm there for the unit will alarm when several persons smoke www lexing com cn mmm Stand Alone Smoke Alarms LX SI 108A F N MULTIPLE FLOOR PLAN Ne SINGLE FLOOR PLAN y Ne arc pes 4 e j re BEDROOM BEDROOM BEDROOM o e O o i 3 O S KITCHEN LIVING ROOM BEDROOM g ra et Yl e Wy SMOKE ALARM FOR MINIMUM PROTECTION O SMOKE ALAR
5. lift to the top of rooms 6 If some reasons cause you can t install them in the middle of ceiling you need to install them at least 10cm away from the wall 7 lf you like to install them on the wall they should be installed 10 30 5cm away under the ceiling Diagram 1 www lexing com cn a Stand Alone Smoke Alarms LX SI 108A 8 You need install more than one alarm when the length of your hall exceeds 9m 9 In an ablique roof room install the alarm 0 9m away from the top Diagram 2 10 How to install smoke alarms in a removable house The removable house is short of heat isolation so you d better install the alarm 10 30 5cm away from the ceiling for safety you need install another one near your bedroom too CEILING MINIMUM LMM ANYWGERE IN THIS AREA MINIMUM 10CM 4 BEST HERE NEVERHERE Si 3g E ACCEPTABLE HERE A d ZZ 0 9M 3ft 0 9M 3ft DIAGRAM 1 7 HORIZONTAL DISTANCE FROM PEAK SIDE WALL 5 Z DIAGRAM 2 i WHERE NOT TO INSTALL SMOKE ALARMS 1 Where combustion particles are produced Combustion particles form when something burns Avoid installing in the areas include poorly ventilated kitchens garages and furnace rooms Keep units at least 6m from the sources of combustion particles stove furnace water heater space heater if possible Ventilate these areas as much as possible 2 In air streams near kitchens Air currents can draw cooking smok
6. victims 2 Smoke alarms are not foolproof they can t prevent or extinguish fires they are not a substitute for property or life insurance You need buy some fire fighting facilities 3 Sometimes the smoke is blocked by objects and can t reach the detector and if the wind blows the smoke away from the detector the unit won t work either HOW TO DO IN CASE OF FIRE 1 Call the Fire Department immediately after confirming the fire 2 Don t panic stay calmly and follow your family escape plan Get out of the house as quickly as possible don t stop to get dressed or collect anything 3 Feel doors before opening them to see if they are hot If a door is cool open it slowly Don t open a hot door use an alternate escape route 4 Cover your nose and mouth with a cloth preferably wet Take short shallow breath 5 Meet at your planned place outside your home and do a head count to ensure everybody go out safely ISO9001 NINGBO LEXING INDUCTOR ELECTRONIC CO LTD Add No 35 Zhuquan Road Science amp Technology Area E mail lexing lexing com cn Ninghai Ningbo Zhejiang China E mail lexing globalmarket com l S O 1400 1 Tel 86 574 65335088 www lexing com cn Fax 86 574 65335000 65335333 www lexing com www lexing com cn a

Download Pdf Manuals

image

Related Search

Related Contents

Batteries Li-ion 18v - 1,5Ah et 3,0Ah  次ページの返金申込書を切り取ってご使用下さい - CLUB T-fal  DirecTV ProScan DSS Receiver User's Manual  Page 1 Page 2 監督者責任の再構成 (三) 目 次 序論 第 一 章 監督者  子育て・教育 お知らせ  ? CONDITIONS DE TRANSPORT  ST 330 - Domyos  FlowerHouse FHFH700SHV Instructions / Assembly  Kingston Technology ValueRAM 4GB DDR3-1333  