1. including amplifiers that produce heat 9 DO NOT defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wider blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet PROTECT the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 ONLY USE attachments accessories specified by the manufacturer OVE 5e 10 13 14 15 16 17 USE only with a cart stand tripod bracket or table Specified by the manufacturer or sold with the Apparatus When a cart is used use caution when moving the cart apparatus combination to avoid hi injury from tip over UNPLUG this apparatus during lightning storms or when unused for long periods of time REFER all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is dam Aged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped DO NOT expose the apparatus to dripping and splashing DO NOT put objects filled with liquid
2. DS E 215 USER S MANUAL DSPOT DIGITAL SIGNAL PROCESSOR GALAXY AUDIO MAKERS OF THE ORIGINAL HOT SPOT PERSONAL MONITOR CDI GALAXY AUDIO EORR ibra 1 Sarety NS UG WS iii 2 Getting Started with Front Panel 3 8 tne PC Interface 9 13 MIDI Program Table c 4 14 Speciali l 15 Introduction Thank you for choosing a Galaxy DSPOT Digital Signal Processor You have joined hundreds of thousands of other satisfied Galaxy customers Since 1977 Galaxy Audio s professional experience in design and manufacturing ensure our products quality performance and reliability For the most up to date manual and information visit www galaxyaudio com This symbol indicates that dangerous voltage Constituting a risk of electric shock is present within this unit Safety Instructions This symbol indicates that there are important Operating and maintenance instructions in the Literature Accompanying This Unit IMPORTANT SAFETY INSTRUCTIONS READ these instructions KEEP these instructions HEED all warnings FOLLOW all instructions DO NOT use this apparatus near water CLEAN ONLY with dry cloth DO NOT block any ventilation openings Install in accordance with the manu facturer s instructions DO NOT install near any heat sources such as radiators heat registers stoves or other apparatus
3. dit QVALUES Controller19 0 1 2 3 4 5 6 7 8 9 0 0 4 0 5 0 6 0 7 0 8 0 9 1 1 2 1 4 0 16 10 1 8 2 2 2 24 2 6 2 8 3 3 2 3 4 3 6 20 3 8 4 4 2 4 4 4 6 4 8 5 5 2 5 4 5 6 30 5 8 6 6 2 6 4 6 6 6 8 7 8 2 8 4 8 6 40 8 8 9 9 2 9 4 9 6 9 8 10 12 14 16 50 18 20 22 24 24 28 30 32 34 36 90 9 100 102 104 104 108 110 110 114 116 100 118 120 122 124 124 128 14 Specifications e lt q FUSE REPLACE WITH 800mA SAME TYPE FUSE it pu 4 INPUTS Fe Q eO DONAT OPEN TAE coves RIGHT OUT LEFT OUT L RIGHT IN LEFT IN Inputs 2 TRS Unbalanced Input Max Level 9dBu Outputs 2 TRS Unbalanced Output Max Level 9dBu AID and DIA Resolution 20 bit Process Resolution 24x32 bit Processes Equalizer Display LCD 2x20 alphanumeric Connectivity RS232 MIDI USB SIN Ratio gt 90 dBA Bypass THD N 0 01 6 dBFS Bypass Frequency Response 20Hz 20kHz 1 0 5dB Dimensions 7 75 x 19 x 1 75 196 85 x 482 6 x 44 45 mm Weight 5 5116 2 5kgs CDI GALAXY AUDIO CDI GALAXY AUDIO gt GALAXY AUDIO MAKERS OF THE ORIGINAL HOT SPOT PERSONAL MONITOR THREE YEAR LIMITED WARRANTY WARRANTY Information can be viewed online at http www galaxyaudio com warranty php www galaxyaudio com warranty php DSPOT DIGITAL SIGNAL PROCESSOR DS EQ215 Specif
4. ect the Limiter Block to access the left and right Limiter parameters 4Acuvuaco i 13 MIDI Program Table Midi Standard Program Change Value Range Legend 0 15 Factory Preset 16 31 User Preset Control Change Controller Range Legend Bank select 0 0 1 2 Bank 1 channel Right Bank 2 Eq Type 14 0 1 0 Parametric 1 Graphic Num Filter Eq 16 0 14 Select num filter Amplitude PEQ 17 0 60 15dB step 0 5dB Frequency PEQ 18 0 120 from 20Hz to 20kHz step 1 12 Oct Band width PEQ 19 0 111 From 0 04 to 128 vedi Tab Q High Pass Frequency 20 0 120 from 20Hz to 20kHz step 1 12 oct High Pass Slope 21 0 1 2 Bypass 6dB Oct 12dB Oct Low Pass Frequency 22 0 120 from 20Hz to 20kHz step 1 12 oct Low Pass Slope 23 0 1 2 Bypass 6dB Oct 12dB Oct Delay Adjust 24 0 99 from 0 to 198ms step 2 ms Delay Fine 25 0 47 from 0 to 1ms step 21 us Mute Unmute 26 0 1 0 Unmute 1 Mute Edit using the following steps I Be sure about the selected equalizer mode 2 Select the channel controller 0 3 Select the number of the filter controller 14 4 Change the amplitude of the selected filter controller 17 5 Change the frequency of the selected filter controller 18 6 Change Q value of the selected filter controller 19 Repeat the steps 3 4 5 6 for each filter you wish to e
5. ication is possible to select the remote control interface to use Use the PARAMETER encoder to select one of the following RS 232 USB or MIDI Channel 1 through15 Use the PARAMETER encoder to change the setting Also check the corresponding setting on the back panel hardware switch To exit press QUIT When the unit is remotely controlled through RS232 or USB null modem cables then the front panel is disabled and the LCD display shows Connectio Config Delay Unit This function allows the user to edit the delay time in meters or in seconds n Config Equ Type This function allows the user to select a graphic equalizer or a parametric equalizer In order to confirm the blinking parameter push the ENTER key There are no problems when changing from graphic equalizer to parametric equalizer When the user asks to turn from parametric equalizer to graphic equalizer then the LCD display shows If the user confirms his request the system automatically changes the frequency and the Q values of each filter to suitable values for 2 3 octave filters When a parametric equalizer preset is loaded when the system is in graphic mode then the system automatically changes the frequency and the Q values of each filter to suitable values for 2 3 octave filters So the user has to be sure to load presets consistent with the current equalizer mode Flat EquL R This function resets all parametric filters of the Left Righ
6. ications in this manual are subject to change without notice For the most up to date manual and information visit www galaxyaudio com 1 800 369 7768 www galaxyaudio com Copyright Galaxy Audio 2014 V02072014 Printed in China
7. ice Demo 10 20 Device Demo 10 21 Device Demo 10 22 Device Demo 10 23 Device Demo 10 24 Device Demo 10 25 Device Demo ID 32 Device Demo The Main Page will load Channel NoseGate p PEQ Xove j Delay Right_ Noise Gate M PEQ H Xove H Dew H 39 10 The device will also be locked out from front panel control at this point You may choose to Load Preset from PC Save Preset to PC Store Preset to Device Read Preset from Device Ji From the main page you can choose the section you want to adjust by clicking on the associated block Once you have accessed the block you can adjust parameters by either using the sliders arrows or typing the values in directly Select the noise gate block to access the noise gate parameters for each channel CHA Let S Right Enable Enable p EH amp Left 4 EH B Fight Threshold Release Attack Threshold Release Attack dB ms sec dB ms sec 11 Select the PEQ block to access the filter parameters High Pass Fiber Frequency 20 o petes Low Pass Fite naota ra TTL Slope Bypass 208 EQ Fikers 0 o J o J o o o e o J c Lo e v Pg Le ms moi dud Sel
8. s such as vases on the apparatus Remove the batteries from the receiver if the system will not be used for a long period of time This will avoid any damage resulting from a defective leaking battery DO NOT throw used batteries into a fire Be sure to dispose of or recycle used batteries in accordance with local waste disposal laws Described below are the functions of the front panel control buttons and encoders for the DS EQ215 Parametric Equalizer 1 Input Level Input Gain Left Right 2 EQ Bypass 3 Output Level Output Volume Left Right 4 LCD Display 5 Clip LED Process Overflow 6 Parameter Key Parameter Variation 7 Enter Key Enters Sub Menus 8 Navigation Key Navigation Menus 9 Escape Key Exit Sub Menus 10 Power Button B Gain L amp R Volume L amp R Parametric Equalizer 2X15 output Edit Parameter Bypass Getting Started Using Front Panel Interface Brief description The DS EQ215 is a graphic parametric 2 channel EQ with 15 15 filters and channel link possibility Its filters are symmetrical and High Low pass filters are included A delay line for each channel is also available Its settings are stored into 16 Factory and 16 User Presets The device can also be linked to acontroller using MIDI RS232 or USB User Interface At power on after the initialization phase the unit shows on the LCD display the following On the upper ro
9. sible to save the preset If the chosen location is occupied the user will see a warning Pressing QUIT the system returns to SAVE menu Pressing ENTER the preset will be saved and the screen will show After that saved preset name editing will be possible Use the NAVIGATION encoder to select character position and the PARAMETER encoder to change the character To save press ENTER To maintain default name press QUIT After this the system returns to main menu If a preset is not saved switching off the device will lose it UTILITY FUNCTION MENU It is possible to select one of these functions 1 LinkL amp R Config Communication Config Delay unit Config Equ type Flat EquL Flat Equ R 0 Copy L to R Copy R to L Use the NAVIGATION encoder to select the desired function and press ENTER to access it Press QUIT to exit G N Link L amp R Link L amp Ris used to set the following configurations Link L amp R OFF Dual mono mode Link L amp R ON Stereo mode If Link amp Ris ON the menu associated functions are reduced and whatever editing is made on the Left channel will be applied also to the Right one Use the PARAMETER encoder to select OFF or ON To confirm press ENTER When passing from OFF to ON the display will show If confirmed this command will wipe out Right channel settings replaced by settings identical to the Left channel Config Commun
10. t channel After pressing ENTER the following will be shown Press ENTER to confirm QUIT to cancel CopyLtoR RtoL This function copies the settings of one channel to the other Press ENTER to show the following message RL Are Yous Enter No Press ENTER to confirm QUIT to cancel EDIT CHANNEL L R MENU This sub menu allows channel parameters editing 1 Equalizer 2 Hp Filter 3 Lp Filter 4 Delay 5 Mute Channel Use the ENCODER to select the desired function and press ENTER to access it press QUIT to exit Equalizer Here it s possible to edit the 15 filters gain 15dB step 0 5dB frequency 20Hz to 20kHz step 1 12 octave bandwidth from Q 0 4 to Q 1 00 step 0 05 from Q 1 00 to Q 10 step 0 1 and from Q 10 to Q 128 step 1 After selecting Equalizer and pressing enter the display shows 1 5 F1K05 Q0 3 01 5 F1K05 QO Using the ENCODER it s possible to select the filter to edit upper right in the display Scrolling all 15 filters the lower row will show the setting of each To edit the selected filter press ENTER The PARAMETER encoder varies the parameter value HP LP Filler This sub menu edits a Butterworth High Low Pass filter Available parameters are frequency 20Hz to 20kHz step 1 12 octave and order filter bypass 1st order 2nd order 7 Upon selecting H L pass and pressing enter the user accesses the menu The PARAMETER encoder varies the parameter val
11. ue Delay This sub menu edits a delay line from Oms to 199 987ms step 21 us The NAVIGATION encoder allows to select the value of hundreds tens units and decimals The selected digit is blinking The PARAMETER encoder allows YOU to change the selected digit Mute This function allows to mute the selected channel Using the PC Interface Using the DS EQ215 Software e Load the Software SetupDS EQ215V1 0 0 either with the included CD or via the Galaxy Website e Double click on Setup choose Run the software will load e Go to programs and double click on DS EQ215V1 0 0 e Connect the SDS EQ215 with the USB cable to your computer e Turn on the DS EQ215 the driver software will load automatically e When the driver has finished loading click once on connect If you want to continue select Yes Connect device s are you sure Choose your connection type Then Click on Connect with one device with several devices The software will look for active devices and show them in a list To edit Double click on the desired device in the ID list 10 02 Device Demo 10 03 Device Demo 10 04 Device Demo 10 05 Device Demo 10 05 Device Demo 10 07 Device Demo 10 08 Device Demo 10 09 Device Demo 10 10 Device Demo ID 11 Device Demo 10 12 Device Demo 10 13 Device Demo 10 14 Device Demo 10 15 Device Demo 10 16 Device Demo 10 17 Device Demo 10 18 Device Demo 10 13 Dev
12. w the preset number and the preset name are visible on the lower row the vu meter shows the input signal level after the analog GAIN L amp R To access the main menu the user pushes the ENTER key or rotate the NAVIGATION encoder To return to the vu meters the user pushes the QUIT key Every time the user pushes a key the LED near it changes its state After an encoder rotation or an ENTER key press the LCD display shows Using the PARAMETER encoder the main menu is accessible through the lower row 1 LOAD PRESET 2 SAVE PRESET 3 UTILITY FUNCTION 4 EDIT CHANNEL L 5 EDIT CHANNEL EDIT CHANNEL won t be shown if the system is configured as Link L amp R ON To select a field use the NAVIGATION encoder To access a sub menu press ENTER To exit press QUIT Enter and quit are also used to confirm user choices LOAD PRESET MENU Here itis possible to select and load one of the 16 16 available presets To select a preset use the PARAMETER encoder Load Preset If the current preset 15 the selected one but has been modified an asterisk will be shown To load the selected preset press ENTER To leave sub menu press QUIT During preset loading the display will show If the user tries to load an empty preset a warning will be given or Preset SAVE PRESET MENU Within this menu use the NAVIGATION encoder to select the desired location between the user presets By pressing enter it is pos