Home

Dataman 48Pro Manual - Dataman Programmers Ltd.

image

Contents

1. nav6 are defined Each value is written to buffer on address A7890 All values have size 6 bytes The line with nav6 label has also second value definition which is written to buffer on address FFFF6 and has size 10 bytes i e the last byte of this value will be written to address FFFFF 63 ni A Note Address for Serialization is always assigned to actual device organization and buffer organization that control program is using for current device If the buffer organization is byte org x8 the Serialization Address will be byte address If the buffer organization is wider than byte e g 16 bit words x16 the Serialization Address will be word address Device Device options Statistics Statistics gives information about the actual count of device operationsfor a selected device If one device is corresponding to one device operation e g For example the number of device operations will be equal to number of programmed devices The next function of statistics is Count down Count down allows checking the number of device operations and then number of devices on which device operations have to be done After each successful device operation the value of the count down counter is decremented The initial Count down value is user defined see the Statistics window When count down value reaches zero the specified number of device operations are is completed A message to the user will then be displayed
2. AlgOR Algorithms On Request form Subject title of problem Date Customer name Address Contact person and E mail Distributor name Date of purchasing Date of sending registration card Programmer type modification Serial number Control program and version Information about device you want to be supported Device type full name Vendor logo Package DIL40 PLCC44 Precedence rating in__ days in__ weeks in__ months Device to be programmed still Y N sometimes Y N one shot Y N Number of programmed device approx ___ pcs per year Samples are available Yes Yes I m sending it attached No Notes to request Description of requested change in control program Enter please feature you want to the program will have Notes e look please at latest list of supported devices before you send this request to us e in case of sending samples attach please to package next declaration for customs Free sample s not for commercial sale Value for customs purposes only 10US 99 l corel pil Appendix C registration card If the registration card is missing from your standard programmer delivery package please use a copy of the form below and send it to Dataman We remind you that without the Extended warranty document only the standard 6 month warranty is granted Programmer Serial number Name Company Department Add
3. The dialog Save project contains three additional windows in Project description panel placed at the bottom of dialog Save project The windows are for displaying information about currently selected project file in dialog Save project and information about current project which has to be saved Dialog Save project contains also additional button with picture of key displayed Clicking on this button password dialog appears which can be used to save project with password Projects with password are special projects also called Protected mode projects For more detailed ain 41 TU LUNI n information about project passwords see Options Protected mode Project information consists of e manufacturer and name of the first device selected in the project e date and time of project creation e user written description of project it can be arbitrary text usually author of project and some notes The first upper window contains information about currently selected project file in dialog Save project The second middle windows displays information about actual program configuration including currently selected device active programmer date time These actual program settings are used for creation of project description header The third bottom window is user editable and contains project description arbitrary text which usually consists of project author and some notes File Reload file Choose this option to rel
4. File options File options page allows you to set file masks auto reload of current file and choose file format File format mask is used for setting file name masks to act as a filter for file listings in the File Save and File Load window Masks may contain one of following wildcards Project file default extension is used for setting project file extension used as default in File Load project and File Save project dialog boxes If the current file is modified by another process three options exist for reloading the actual file 1 Prompt before reloading file 2 Reload automatically 3 Ignore change scanning of current file There are three situations when file modification is tested e switching to the control program from another application e selecting the device operation Verify or Program e when repeat of last device operation is selected in dialog Repeat Load file format allows setting the file format recognition mode When automatic file format is selected program determines the format automatically If file format matches one of supported formats the file is read to buffer in the detected format Manual file format allows the user to select explicitly the file format The file may be loaded incorrectly if the file format does not match the user selected format Hex file options This page contains several options for loading control by any of HEX formats SSS S SS ____ _ _ 77
5. File Load Select the file format and load the data from specified file to the buffer You can choose the format desired binary MOTOROLA MOS Technology Tektronix Intel extended HEX ASCII space JEDEC and POF The control program stores a last valid mask for file listing You can save the mask into the config file by command Options Save options Selecting Automatic file format recognition tells program to detect file format automatically When program can t detect file format from one of supported formats the binary file format is assumed When the check box Automatic file format recognition is unchecked the program allows user to manually select the file format from list of available formats on the panel Selected file format Default set is from Options General options in panel Load file format at tab File options Selecting Buffer offset for loading tells the program to set buffer offset for all data addresses which will be written to buffer This feature is useful for binary and all HEX formats Using this one shot setting disables current setting of native offset in menu Options General options in panel Negative offset for loading at tab Hex file options Selecting Erase buffer before loading tells the program to erase all buffer data using entered Erase value Buffer erase is performed immediately before reading file content to buffer and it is functional for binary and all HEX file formats Using this one shot s
6. Statistics dialog box contains following options Check boxes Program Verify Blank Erase and Read define operations after which statistics values increment Check box Count down sets Count down activity enable or disable Edit box following the Count down check box defines initial number of count down counter from which count down starts Statistics dialog box can be also opened by pressing right mouse button on the Statistics panel and clicking Statistics Actual statistics values are displaying in main window of control program in Statistics panel Statistics panel contains three statistics values Success Failure Total and two Count down values Count down and Remains Meaning of the values is Success number of operations which where successfully completed Failure number of operations which where not successfully completed Total number of all operations 64 Software Count down informs about Count down activity Enabled or Disabled Remains informs about the number of devices remaining A successful operation means any device operation completed without errors e program e verify e blank check e erase e read If device operation terminates with error s it is not successful operation When new device type is selected all statistics values are set to zero and Count down is Disabled Reset button in the Statistics panel reset statistics values Reload Count down button in Statistics panel r
7. in ZIF 17 sec PIC16F876A programming and verify ISP 5 sec PIC12C508 programming and verify ISP 3 sec System P4 2 4GHz USB 2 0 Windows XP SOFTWARE e Algorithms only manufacturer approved or certified algorithms are used Custom algorithms are available at additional cost e Algorithm updates software updates are available approx every 2 weeks free of charge e Main features revision history session logging on line help device and algorithm information Device operations e standard e intelligent device selection by device type manufacturer or partial part name e blank check read verify e program 32 Dataman 40Pro erase configuration and security bit program illegal bit test e checksum e security e insertion test e contact check e ID byte check e special e auto device serial number increment e statistics e count down mode Buffer operations e view edit find replace e fill copy move byte swap word dword split e checksum byte word e print File load save e no download time because programmer is PC controlled e automatic file type identification Supported file formats e unformatted raw binary e HEX Intel Intel EXT Motorola S record MOS Exormax Tektronix ASCII SPACE HEX e JEDEC ver 3 0 A for example from ABEL CUPL PALASM TANGO PLD OrCAD PLD PLD Designer ISDATA etc PC system requirements See section Introduction P
8. address is moved to a lower even address and or end address is moved to a higher odd address Buffer Erase This command fills the content of the buffer with the blank character The key lt Ctrl F2 gt is the hot key Buffer Fill random data If this This command fills the content of the buffer with random data The reserved key lt Shift Ctrl F2 gt is the hot key Buffer Duplicate buffer This command duplicates the buffer content in the source EPROM address range to the address range of the destination EPROM For example this command will copy the address range of a 27C256 three times to fill address range of a 270010 EPROM Note The procedure always uses buffer start address 00000h Buffer Checksum The checksum dialog is used for calculate checksums of selected block s in the buffer The checksums are calculated as such Byte sum by bytes to word CY flag is ignored Word sum by words to word CY flag is ignored Byte CY sum by bytes to word CY flag is added to result Word CY sum by words to word CY flag is added to result 47 NU il Li CRC CCITT sum by bytes to word using RESULT PREVIOUS x 16 x 12 x 5 1 CRC XModem sum by bytes to word using RESULT PREVIOUS x 16 x 15 x 2 1 Column marked as Neg is a negation of checksum so that Sum Neg FFFFH Column marked as Suppl is complement of checksum so that Sum Suppl 0 carry Dialog checksum c
9. 4 5 double click to selected LPT port to show properties of the port 6 inthe LPT port properties dialog select the page Port settings 7 change number of LPT port to LPT1 by LPT Port Number setting 8 click OK button 9 restart the operating system even if system does not require restart it is necessary to perform system restart to correctly initialize our LPT port driver That s all Our software should work properly with LPT connected programmer When using programmer connected through USB there is no need of LPT port driver USB driver For programmers connected through USB port control program requires correctly installed USB driver We recommend to install control program first and then connect programmer to USB port Windows will detect new hardware as USB programmer automatically When the programmer is connected to USB port before control program was installed Windows will detect new hardware and ask user to select driver installation method automatically or manually To detect programmer correctly control program installation CD must be inserted to computer s CD ROM drive and following steps have to be done driver installation steps bellow are used for Windows XP but other Windows versions have similar steps STEP 1 The first time a new USB device is plugged into a Windows XP system a dialog box will appear indicating that the system has found a new hardware device There may also be a dialo
10. _ _ _ _ _ _ 57 pil Style Hex Save to buffer LS Byte first Address 7FFFCH Start value 16000000H Step 1 Following values will be written to device The 1st device Address Data OO7FFFO xx xx XX XX XX XX XX XX XX XX XX XX 00 00 00 16 The 2nd device Address Data OO7FFFO xx xx XX XX XX XX XX XX XX XX XX XX 01 00 00 16 The 3rd device Address Data OO7FFFO xx xx XX XX XX XX XX XX XX XX XX XX 02 00 00 16 etc xx mean user data programmed to device Serial numbers are written to device from address 7FFFCH to address 7FFFFH because serial number size is 4 bytes 2 Following example shows usage of SQTP serialization mode when serial number is split into RETLW instructions for Microchip PIC16F628 devices Note Serial quick turn programming SQTP is Microchip specified standard for serial programming of Microchip PIC microcontrollers Microchip PIC devices allows you to program a unique serial number into each microcontroller This number can be used as an entry code password or ID number Serialization is done by using a series of RETLW Return Literal W instructions with the serial number bytes as the literal data To serialize you can use Incremental mode serialization or From file mode serialization Incremental serialization offers serial number Split function Serial number split allows usage of incremental numbers separated into even or odd bytes and between each byte of serial number RETLW instruction
11. and buffer address to write to buffer One optional part can be defined after basic part of data label 7 labeln labels Labels are identifiers for each line of input file They are used for addressing each line of file The labels should be unique Addressing lines of file means the required start label entered by user defines line in input file from which serial values reading starts addr Addr defines buffer address to write data following the address byted byten byted bytem byted bytek Bytes arrays byted byten byte0 bytem and byted bytek are defining data which are assigned to write to buffer Maximum count of bytes in one data field following the address is 64 bytes Data bytes are written to buffer from address addr to addr n The process of writing particular bytes to buffer is byteO to addr byte to addr 1 byte2 to addr 2 byten to addr n Optional part is delimited from the first data part by character comma and its structure is the same as in the first data part i e address and following array of data bytes Characters with special use labels must be defined inside square brackets 62 Software character which delimiters basic part and optional part of data 7 the semicolon character means the beginning of a comment All characters from to the end of line are ignored Comment can be on individual line or in the end of definition line Note e Label
12. code is inserted From file serialization is using proprietary serial numbers file This file can consist of various serial numbers The numbers can have format suitable for SQTP that means number RETLW b1 RETLW b2 and so on Note that PG4UW serial file format is not compatible with SQTP serial file generated by Microchip MPLAB Device PIC16F628 has 14 bit wide instruction word Instruction RETLW has 14 Bit Opcode m z 58 Software Description MSB 14 Bit word LSB RETLW Return with literalin W11 O1xx kkkk KKKK where xx can be replaced by 00 and k are data bits i e serial number byte Opcode of RETLW instruction is hexadecimal 34KKH where KK is data Byte serial number byte Lets assume we want to write serial number 1234ABCDH as part of four RETLW instructions to device PIC The highest Byte of serial number is the most significant Byte We want to write the serial number to device program memory at address 40H Serial number split us very useful in this situation Serialization without serial number split will write the following number to buffer and device AddressData 0000080 CD AB 34 12 xx xx XX XX XX XX XX XX XX XX XX XX Note address 80H is because buffer has byte organization and PIC has word organization so it has equivalent program memory address 40H When buffer has word organization x16 the address will be 40H and number 1234ABCDH will be placed to buffer as following Address Data 0000040 ABCD 1234 xxxx X
13. command means a higher reliability for device reading Device Verify This command compares the programmed data of the device with the data in the buffer The control program displays the result of this action by a message to the INFO window The menu command Device Device options Operation options allows the setting of parameters related to the verify device operation In the menu Options Display errors the errors can be displayed on the screen written to the file VERIFY ERR or disabled Device Program This command allows the programming of the device or part of it by the data in the buffer The control program displays the result of this action by a message to the INFO window The menu command Device Device options Operation options allows the setting of parameters related to the program device operation Device Erase This command allows erasing of the entire programmable device The control program displays the result of this action by a message to the INFO window Device Test This command executes a test on the selected device selected from list of supported devices e g static RAM on programmers which support this test Device IC test This command activates a test section for ICs separated by type to any libraries on distribution CD First select an gi 66 Software appropriate library wished device and then a mode for test vectors run LOOP SINGLE STEP Control sequence and
14. device insertion test wrong or backward position and a contact check poor contact pin to socket before it programs each device These capabilities supported by overcurrent protection and signature byte check help prevent chip damage due to operator error Built in protection circuits eliminate damage of programmer and or programmed device due environment or operator E 13 cone LI failure All the inputs of the Dataman 48Pro programmer including the ZIF socket connection to PC and power supply input are protected against ESD up to 15kV Dataman 48Pro programmer performs device verification at the upper and lower limits of the supply voltage which improves programming yield and guarantees long data retention Various socket converters are available to handle device in PLCC SOIC PSOP SSOP TSOP TSSOP TQFP QFN MLF SDIP BGA and other packages Dataman 48Pro programmer is driven by an easy to use control program with pull down menus hot keys and on line help Selecting a device can be done by class manufacturer or by simply typing in part of the vendor name or part number Standard device related commands read blank check program verify erase are enhanced by test functions insertion test signature byte check and special functions autoincrement production mode start immediately after insertion of chip into socket All Known data formats are supported The file format is automatically detected du
15. disk used for temporary data storage Printer port type of port of PC parallel which is primarily dedicated for printer connection HEX data format format of data file which may be read with standard text viewers e g byte 5AH is stored as characters 5 and A which is ASCII bytes 35H and 41H One line of this HEX file one record contains start address and data bytes All records are secured with a checksum Introduction Introduction This user s manual covers the following programmers Dataman 48Pro and Dataman 40Pro Dataman 48Pro is a fast universal USB LPT programmer and logic IC tester with 48 powerful pindrivers Using a built in in circuit serial programming ISP connector the programmer is able to program ISP capable chips Also the modular design allows new devices to be easily added to the device list The Dataman 48Pro is a true universal and a low cost programmer providing the most cost effective programmer in today s market Dataman 40Pro is a small fast and powerful USB programmer with many supported programmable devices Using a built in in circuit serial programming ISP connector this programmer is able to program ISP capable chips This programmer is also designed to allow new devices to be easily added to the device list These programmers work with almost any IBM PC Pentium compatible or higher portable or desktop personal computers No special interface card is required to connect to
16. not work properly please run the programmer selftest using the Diagnostic POD The Diagnostic POD is included with the standard package For optimal results we recommend you run the programmer selftest and calibration every 6 months See instructions for selftest in the Diagnostics menu of PG4UW 18 Dataman 48Pro Technical specification HARDWARE Base unit DACs e USB 2 0 port e FPGA based IEEE 1284 slave printer port up to 1MB s transfer rate e on board intelligence powerful microprocessor and FPGA based state machine ethree D A converters for VCCP VPP1 and VPP2 controllable rise and fall time e VCCP range 0 8V 1A e VPP1 VPP2 range 0 26V 1A e autocalibration e selftest capability e protection against surge and ESD on power supply input parallel port connection Socket pindriver e 48 pin DIL ZIF Zero Insertion Force socket accepts both 300 600 mil devices up to 48 pin e pindrivers 48 universal e VCCP VPP1 VPP2 can be connected to each pin e ground for each pin e FPGA based TTL driver provides H L CLK pull up pull down on all pindriver pins e analog pindriver output level selectable from 1 8 V up to 26V e current limitation overcurrent shutdown power failure shutdown e ESD protection on each pin of socket IEC1000 4 2 15kV air 8kV contact e continuity test each pin is tested before every programming operation 19 MA hile ISP connector e 10 pin male connector wit
17. of course by mouse Hot keys are available for even quicker selection of intensely used commands Note Data entered through keyboard is in HEX format excepting ASCII blocks in Buffer View Edit command List of hot keys lt F1 gt Help Calls Help lt F2 gt Save Save file lt F3 gt Load Load a file into the buffer lt F4 gt Edit Viewing editing of buffer lt F5 gt Select default Target device selection from 10 last selected devices list lt Alt F5 gt Select manual Target device selection by typing device vendor name lt F6 gt Blank Blank check lt F7 gt Read Reads device s content into the buffer lt F8 gt Verify Compares contents of the target device with the buffer lt F9 gt Program Programs target device lt Alt Q gt Exit without save Terminates the PG4UW lt Alt X gt Exit and save Terminates the PG4UW and saving settings too lt Ctrl F1 gt Displays additional informa tion about current device lt Ctrl F2 gt Erase Fill s the buffer with a given lt Ctrl Shift F2 gt File value Fill s the buffer with random values This submenu is used for source files manipulation settings and viewing directory changes drives changes start and finish address of buffer for loading and saving files by binary MOTOROLA MOS Technology Intel extended HEX Tektronix ASCII space JEDEC and POF format The menu 38 Software commands for loading and saving projects are located in this submenu too
18. test results are displayed to LOG WINDOW In case of need is possible to define the test vectors directly by user Detailed description syntax and methods of creation testing vectors is described in example_e lib file which is in programs installation folder Note Because the rising falling edges of programmers are tuned for programming of chips it may happen the test of some chips fails although the chips aren t defective counters for example Device JAM VME Player Jam STAPL was created by Altera engineers and is supported by a consortium of programmable logic device PLD manufacturers programming equipment makers and test equipment manufacturers The Jam Standard Test and Programming Language STAPL JEDEC standard JESD 71 is a standard file format for ISP In System Programming purposes Jam STAPL is a freely licensable open standard It supports programming or configuration of programmable devices and testing of electronic systems using the IEEE 1149 1 Joint Test Action Group JTAG interface Device can be programmed or verified but Jam STAPL does not generally allow other functions such as reading a device The Jam STAPL programming solution consists of two components Jam Composer and Jam Player The Jam Composer is a program generally written by a programmable logic vendor that generates a Jam file jam containing the user data and programming algorithm required to program a design into a device The J
19. which serialization will start Generally the max value for serialization is 1 FFFFFFF in 32 bit long word When the actual serial value exceeds maximum value three most significant bits of serial number are set to zero After this action the number is always inside 0 1 FFFFFFF interval this is basic style of overflow handling Step Step options specify the increment step of serial value incrementation S N mode S N mode option defines the form in which serial value has to be written to buffer Two options are available e ASCII e Bin ASCII means the serial number is written to buffer as ASCII string For example number 0528CD is in ASCII mode written to buffer as 30h 35h 32h 38h 43h 44h 0 5 2 8 C D i e six bytes Bin means the serial number is written directly to buffer If the serial number has more than one byte length it can be written in one of two possible byte orders The byte order can be changed in Save to buffer item 56 Software Style Style option defines serial number base There are two options e Decimal e Hexadecimal Decimal numbers are entered and displayed using the characters 0 through 9 Hexadecimal numbers also use characters A through F The special case is Binary Dec which means BCD number style BCD means the decimal number is stored in hexadecimal number i e each nibble must have value from 0 to 9 Values A to F are not allowed as
20. wil me The first option enables erasing of the buffer with desired value automatically before Reloading by any of the HEX formats The second option sets a negative offset which is used for data address modifications by loading from any HEX file so that data can be written to existing buffer addresses Manual or Automatic negative offset mode can be set We recommend automatic set of negative offset in special cases only This option contain a heuristic analyze which can treat some data in file incorrectly There are especially critical files which contain a fragmented addresses range and which exceeds a size of selected device some block can be ignored Automatic set of negative offset can be disabled by select of any special devices No address range in files associated with special devices can be moved and no block can be removed from the file when reading the file For special devices following negative offset options are available Yes negative offset is turned on and No negative offset is not used Example A file contents data in Motorola S format A data block started at address FFFFOH It is a S2 format with length of address array of 3 bytes For all data reading you can set a value of negative offset to FFFFOH It means that the offset will be subtracted from current real addresses and so data will be written from buffer address 0 Warning The value of negative offset is subtracted from real address and therefore c
21. 000 cycle warranty on ZIF socket 26 Dataman 40Pro Dataman 40Pro elements 40 pin ZIF socket LED power sleep LED which indicate work result YES button USB connector for PC gt Dataman 40Pro communication cable Power supply connector Connector for ISP si al Power supply connector 27 EL yee Note Due to the low power consumption when in an inactive state the Dataman 40Pro doesn t require power switch When the power LED indicator glows with a low intensity the Dataman 40Pro is in inactive mode Connecting Dataman 40Pro to PC For Dataman 40Pro the order of connecting the USB cable and power supply to programmer is irrelevant Problems related to the Dataman 40Pro PC connection If you have any problems with Dataman 40Pro PC connection see section Common notes please Manipulation with the programmed device After selecting the desired part you can insert it into the open ZIF socket the lever is up and then close socket the lever is down to begin programming The correct orientation of the programmed device in ZIF socket is shown on the picture near ZIF socket on the programmer s cover It is necessary to insert the device into the socket and to also close the socket Make sure not to remove the device from the socket when the LED BUSY is on Warning The Dataman 40Pro programmer doesn t protect devices against critical situations for example power failure
22. 0ms 500ms or 1s Inactive level of ISP signals this parameter determine level of ISP signals after finishing access to target device Signals of ISP connector can be set to Pull up signals are tied through 22k resistors to supply voltage or Pull down signals are tied through 22k resistors to ground Keep ISP signals at defined level after operation enables keeping set level of ISP signals after access to target device finished Control program indicates activated pull up pull down resistors by displaying window with warning After user close this window control program will deactivate resistors Device Device options Serialization Serialization is special mode of program When a serialization mode is activated a specified value is automatically inserted on predefined address into buffer before programming each device When more devices are programmed one by one the serial number value is changed for each device automatically and inserted into buffer before programming device so each device has unique serial number There are two types of serialization e Incremental mode e From file mode If a new device is selected the serialization function is set to a default state i e disabled _ EE _ gt E gt E gt s E S Z 54 Sofiware Actual serialization settings for actually selected device are saving to disk along with associated device by File Exit and save command When incremental mode is active follo
23. 40Pro is competitively priced with excellent hardware design for reliable programming Dataman 40Pro offers very fast programming due to high speed FPGA driven hardware and USB 2 0 full speed port It is surely faster than competitors in this category Dataman 40Pro_ interfaces with the IBM PC Pentium compatible or higher portable or desktop personal computers through USB port Therefore you can take the programmer and move it to another PC without assembly disassembly of the PC Dataman 40Pro has 40 powerful TTL pindrivers to provide H L pull_up pull_down and read capability for each pin in the socket Advanced pindrivers incorporate high quality high speed circuitry to deliver signals without overshoot or ground bounce for all supported devices Pin drivers operate down to 1 8V so you ll be ready to program the full range of today s advanced low voltage devices The programmer performs a device insertion test wrong device position in socket and contact check poor contact pin to socket before it programs each device These capabilities supported by signature byte check help prevent chip damage due to operator error The programmer s hardware offers enough resources for a detailed selftest The control program is able to check pindrivers voltages levels and communication between the programmer and the PC Dataman 40Pro programmer performs a device verification at the upper and lower limits of the supply voltage which imp
24. C requirements GENERAL e operating voltage 15 20V DC max 500mA e power consumption max 6W active 1 4W inactive e dimensions 160x97x35 mm 6 3x3 8x1 4 inch e weight without external power adapter ca 500g 17 65 02 e temperature 5 C 40 C 41 F 104 F e humidity 20 80 non condensing Package included e Dataman 40Pro programmer e USB connection cable e ISP cable a 33 e diagnostic POD for selftest anti dust cover for ZIF socket suitable power supply adapter user manual software registration card transport case Additional services e AlgOR e free technical support e free life time software update via our website www dataman com 34 Software Software ue The programmer software The programmer package contains a CD with the control program useful utilities and additional information Permission is granted to freely copy the CD in order to demonstrate how the programmer works Updates to this manual may be found at our website www dataman com Installing the programmer software Installing the programmer software is very easy Insert the CD to your CD ROM drive and the install program should start automatically The install program setup exe will guide you through the installation process prior to using your programmer Program PG4UW exe is the common control program between the Dataman 40Pro and Dataman 48Pro This program will work on systems running Windows 95 98 Me N
25. T 2000 XP New versions of programmer software In order to use all of the capabilities of the programmer we recommend using the latest version of PG4UW You may download the latest version of programmer software from our Internet site www dataman com You may also obtain a CD with this file by postal mail a mailing charge will apply Please contact us for details Upgrading the programmer software Copy PG4UWARC exe to a temporary directory then launch it After extraction you will see all available files needed for the installation process Then redo a standard installation run the Setup program You may delete all files from the temporary folder after the installation process is complete Using the programmer software The control program delivered by Dataman included on the CD in your package is granted to be free from any viruses at the moment of delivery 36 Software Run the control program In Windows environment double click to icon PG4UW After starting the control program PG4UW automatically scans all existing ports for a connected Dataman programmer Program PG4UW will try to find all supported Dataman 48Pro and Dataman 40Pro programmers Note When PG4UW is started it performs an integrity check then displays a standard user menu and waits for your instructions If the control program cannot communicate with the programmer an error message appears on the screen including error code and descriptio
26. Thank you for purchasing assumed that the user has a high quality Dataman some experience with programmer computers and software installation Once you have installed the control program we recommend you consult the context sensitive HELP within the control program rather than the printed User s Manual Revisions are implemented in the context sensitive help before the printed User s Manual Note This Users manual is used for two different programmers Please read the section s relevant to your respective programmer This manual contains two main sections Quick Start Read this section if you are an experienced user You will find only specific information regarding installation of the control program and use of your programmer For more detailed instructions you may read the Detailed description section or the Troubleshooting chapter for your respective programmer Detailed description Read this section if you are a less experienced user or if you need additional information All programmer features are described in this section along with details regarding installation of the control program Read this section to explore all of the features provided by your programmer We continuously update our manual You may find the latest version from our website www dataman com MAN Gi Hilt Table of contents How to use this MAnual cccccccccccesssseeeeeeessseeeeeeeesesseseeeeeeeeeees Introduc
27. Ttiny AT90Sxxx ATmega series 1 2 Microcontrollers Cypress CY8Cxxxxx Microcontrollers ELAN EM78Pxxx Microcontrollers EM Microelectronic 4 and 8 bit series microcontrollers Microchip PlCmicro PIC10xxx PIC12xxx PIC16xxx PIC17Cxxx PIC18xxx dsPIC series 8 40 pins 172 microcontrollers Scenix Ubicom SXxxx series Programmer through ISP connector D 31 nil e Serial E E PROM IIC series e Microcontrollers Atmel AT89Sxxx AT90Sxxxx ATtiny ATmega series e Microcontrollers Cypress CY8C2xxxx e Microcontrollers Elan EM78Pxxx e Microcontrollers EM Microelectronic 4 and 8 bit series e Microcontrollers Microchip PlCmicro PIC10xxx PIC12xxx PIC16xxx PIC17xxx PIC18xxx dsPIC series e Microcontrollers Philips LPC series Notes e 1 suitable adapters are available for non DIL packages e 2 there are only a few adapters for devices with more than 40 pins If you need to program devices with more than 40 pins consider a more powerful programmer such as the Dataman 48Pro eFor all supported devices see our Device list at www dataman com LC Tester e Static RAM 6116 624000 Programming speed Device Operation Mode Time 270010 programming and verify in ZIF 29 sec AT29C040A programming and verify in ZIF 41 sec AM29F040 programming and verify in ZIF 95 sec PIC16C67_ programming and verify in ZIF 10 sec PIC18F452 programming and verify in ZIF 7 sec AT89C52 programming and verify
28. User s Manual for Dataman 48Pro Universal 48 pindriver Programmer with USB LPT interface and ISP capability Dataman 40Pro Universal 40 pindriver Programmer with USB interface and ISP capability July 2005 He COPYRIGHT 2005 Dataman Programmers Ltd This document is copyrighted by Dataman Programmers Ltd United Kingdom All rights reserved This document or any part of it may not be copied reproduced or translated in any form or in any way without the prior written permission of Dataman Programmers Ltd The control program is copyrighted by Dataman Programmers Ltd The control program or any part of it may not be analyzed disassembled or modified in any form on any medium for any purpose Information provided in this manual is intended to be accurate at the moment of release but we continuously improve all our products Please check for an updated manual on our website at www dataman com Dataman Programmers Ltd assumes no responsibility for misuse of this manual Dataman Programmers Ltd reserves the right to make changes or improvements to the product described in this manual at any time without notice This manual contains names of companies software products etc which may be trademarks of their respective owners Dataman Programmers Ltd respects those trademarks ZLI 0294A How to use this manual This manual explains how to install the control Dear customer program and how to use your programmer It is
29. Verify right mouse button e in menu select item Output Stapl file Stop writing to Stapl file 3 run PG4UW select device e g Xilinx XC2x32A QFG32 Jam load Jam file Files of type select STAPL File 4 choose Device operation option Alt O press button Jam configuration Warning Select device from menu Select Devices and Jam file is probably different Continue choose Yes Xilinx sw does not include line NOTE DEVICE XC2x32A in Jam file In dialog Jam player select action and procedures finish dialogs press button Play Jam from toolbar and read Log window The ispVM Virtual Machine is a Virtual Machine that has been optimized specifically for programming devices which are compatible with the IEEE 1149 1 Standard for Boundary Scan Test The ispVM EMBEDDED tool combines the power of Lattice s isoVM Virtual MachineTM with the industry standard Serial Vector Format SVF language for Boundary Scan programming and test The ispVM System software generates VME files supporting both ispJTAG and non Lattice JTAG files which are compliant to the IEEE 1149 1 standard and support SVF or IEEE 1532 formats The VME file is a hex coded file that takes the chain information from the ispVM System window The devices can be programmed in ZIF socket of the programmer or in target system through ISP connector It is indicated by PLCC44 VME or ISP VME suffix after name of selected device in control p
30. XC9500 XC9500XL XC9500XV CoolRunner XPLA3 CoolRunner Il e other PLD SPLD CPLD series AMI Atmel AMD Vantis Gould Cypress ICT Lattice NS Philips STM VLSI TI e Microcontrollers 48 series 87x41 87x42 87x48 87x49 87x50 series e Microcontrollers 51 series 87xx 87Cxxx 87LVxx 89Cxxx 89Sxxx 89LVxxx all manufacturers Philips LPC series e Microcontrollers Intel 196 series 870196 KB KC KD KT KR e Microcontrollers Atmel AVR AT90Sxxxx ATtiny ATmega series 20 Dataman 48Pro e Microcontrollers Cypress CY8CXxxxx e Microcontrollers ELAN EM78Pxxx e Microcontrollers Microchip PlCmicro PIC10xxx PIC12xxx PIC16xxx PIC17Cxxx PIC18xxx dsPIC series e Microcontrollers Motorola 68HC05 68HC08 68HC11 series e Microcontrollers National COP8xxx series e Microcontrollers NEC uPD78Pxxx series e Microcontrollers Scenix Ubicom SXxxx series e Microcontrollers SGS Thomson ST6xx ST7xx ST10xx series e Microcontrollers Tl MSP430 and MSC121x series e Microcontrollers ZILOG Z86 Z89xxx and Z8xxx series e Microcontrollers other EM Microelectronic Fujitsu Goal Semiconductor Hitachi Holtek Princeton Macronix Winbond Infineon Siemens NEC Samsung Toshiba Programmer through ISP connector e Serial E E PROM IIC series e Microcontrollers Atmel AT89Sxxx AT90Sxxxx ATtiny ATmega series e Microcontrollers Cypress CY8C2xxxx e Microcontrollers Elan EM78Pxxx e Microcontrollers EM Microelec
31. XXX XXXX XXXX XXXX XXXX We want to use RETLW instruction so buffer has to be Address Data 0000040 34CD 34AB 3434 3412 xxxx XXXX XXXX XXXX We can do this by following steps a write four RETLW instructions at address 40H to main buffer this can be done by hand editing buffer or by loading file with proper content The bottom 8 bits of each RETLW instruction are not important now because serialization will write correct serial number bytes at bottom 8 bits of each RETLW instruction The buffer content before starting device program will look for example as following AddressData 0000040 3400 3400 3400 3400 xxxx KANA XXXX XXXX 59 8 bits of each RETLW instructions are zeros they can have any value b Set the serialization options as following S N size 4 Bytes Address 40H Start value 1234ABCDH Step 1 S N mode BIN Style HEX Save to buffer LS Byte first Check the option Split serial number at every N byte s and split value N set to 2 It means split of serial number to buffer at every second Byte The correct serial number is set tightly before device programming operation starts The buffer content of serial number when programming the first device is Address Data 0000040 34CD 34AB 3434 3412 XXXX XXXX XXXX XXXX That s it 3 Following example uses the same serialization options as Example number 2 instead the serial number split is set to 3 and 4 When Split serial number at every 3 b
32. am Player is a program that reads the Jam file and applies vectors for programming and testing of devices in a JTAG chain The devices can be programmed in ZIF socket of the programmer or in target system through ISP connector It is indicated by PLCC44 Jam or ISP Jam suffix after name of selected device in control program Multiple devices are possible to program and test via JTAG chain JTAG chain ISP Jam More information on the website http www altera com support devices programming jam dev isp_jam html In System Programmability Guidelines http www altera com literature an an100 pdf Using Jam STAPL for ISP amp ICR via an Embedded Processor http www altera com literature an an122 pdf 67 Software tools Altera MAX plus Quartus Il SVF2Jam utility converts a serial vector file to a Jam file LAT2Jam_ utility converts an ispLSI3256A JEDEC file to a Jam file Xilinx Xilinx ISE Webpack or Foundation software generates STAPL file or SVF file for use by utility SVF2Jam JAM player dialog Jam Player Action Variables Identifier Optional Recommended DO_ERASE s DO_BLANKCHECK z DO_PROGRAM DO_VERIFY DO_READ_UES DO_READ_USERCODE DO_SECURE DO_SECURE_ALL NA Cancel Information Help Device according to Jam file EPM70644E Jam Player version 1 see Action and Variables controls Jam Player Acton i i lt Procedures Iden
33. andom data F9 go to address F10 change mode view edit F11 switch the mode of buffer data view between 1 bit and 8 bit view It can be also do by mouse clicking on the button to the right of View Edit mode buffer indicator This button indicates actual data view mode 1 bit or 8 bit too Arrow keys move cursor up down right and left Home End jump on start end current line PgUp PgDn jump on previous next page Ctrl PgUp PgDn jump on start end current page Ctrl Home End jump on start end edit area Backspace move cursor one position left back Note Characters 0 and 1 immediately changes content of edit area Buffer Fill block This command fills the selected block of the buffer with the hex or Ascii string Enter the block start and block end address as required The default is the size of the selected device Buffer Copy block This command is used to copy a specified block of data to a new address within the current buffer space 46 Software Buffer Move block This command is used to move a specified block of data to a new address within the current buffer space Source address block or part of will be filled by the blank character Buffer Swap block This command swaps the high and low order of byte pairs in current buffer block This block must start on even address and must have an even number of bytes If these conditions are not fulfilled the program modifies the addresses itself start
34. are PG4UW is common control program for some Dataman programmers Thus during work with him it is possible to find some items those refer not to current selected programmer Some special devices e g Philips Coolrunner family require external DAT files that aren t present in standard PG4UW SW delivery on CD If you need to program these devices look at www dataman com section Download You can start control program with different command line parameters Basic rules for using of executive command line parameters 1 command line parameters are not case sensitive 2 command line parameters can be used when first starting of program or when program is already running 3 if program is already running then any of command line operation is processed only when program was not busy no operation was currently executing in program Program must be_ in basic state i e main program window focused no modal dialogs displayed no menu commands opened or executed 4 order of processing command line parameters when using more parameters together is defined firmly as following Load file Load file Load project Prj EPROM Flash select by ID Program device Program switch Close of control program Close only together with parameter Program aOPonh gt Available command line parameters Axxx check programmer present on LPT port with address xxx only example A3bc SPP force PC lt gt programmer communicati
35. ata type i e Boolean or integer Each statement usually occupies one line of the Jam program but this is not required Line breaks are not significant to the Jam language syntax except for terminating comments An apostrophe character can be used to signify a comment which is ignored by the interpreter The language does not specify any limits for line length statement length or program size More informations can be found on the website http www altera com support devices programming jam dev isp_jam html Jam file with extension joc is Jam STAPL Byte code format which is not visible Converting JED file to Jam STAPL file for XILINX devices 1 install Xilinx Integrated Software Environment ISE 6 3i software free download WebPACK_63_fcfull_i exe 6_3 02i_pc exe 315MB or so 2 run Xilinx ISE 6 Accessories IMPACT e in dialog Operation Mod Selection What do you want to do first choose Prepare Configuration Files EE 70 Software in dialog Prepare Configuration Files want create a choose Boundary Scan File in dialog Prepare Boundary Scan File want create a choose STAPL File in dialog Create a New STAPL File write name of Jam file with extension stapl in dialog Add Device select JED file with extension jed in the created jtag chain select device e g XC2C32A left mouse button and select sequence operation e g Erase Blank Program
36. circuit can be activate to switch the programmer in safe status as in case communication PC programmer error LPT port driver For programmers connected through parallel LPT port control program requires correctly installed LPT port driver LPT port driver installation and uninstallation is made automatically by installation program Normally there are no problems with the driver But sometimes driver can not be initialized correctly It is especially in the case that no LPT1 port is present in the Windows NT 2000 XP operating systems When the LPT port driver is not initialized control program can not detect any LPT ports in the system LPT driver requires port LPT1 to be present in the operating system Please check the parallel port LPT1 is present in the system The short description how to see LPT ports present in operating system 1 click to Start menu 2 click with right mouse button to My computer item and select menu Properties 3 in the System properties dialog select Hardware page and click to Device manager button 89 Hilt 4 in the Device manager dialog select Ports Com amp LPT double click it will show the list of all present LPT and COM ports There should be displayed at least one present LPT port If there are present one or more LPT ports but with numbers other than LPT1 it is necessary to change one of the LPT ports to LPT1 port Follow the steps bellow continued from steps 1
37. control program will find all supported programmers Establish communication allows manual or automatic establishing communication for a new programmer 72 Software Speed sets communication speed If manual is selected note that the speed is expressed as a percent from a maximal speed The communication speed modification is important for PCs with slow LPT ports which haven t sufficient driving power for a PC lt gt programmer cable laptop notebook Use this command if you have any communication problems with connected programmer on the LPT port of your PC e g control program reports a programmer absence the communication with the programmer is unreliable etc If automatic establishing communication is selected then control program sets a maximal communication speed Port selects a LPT port which will be scanned for a requested programmer If All port is selected the control program scans all LPT ports which are available on standard addresses Address for special port sets address of LPT port if a Special port is selected Pressing key lt Enter gt or button OK initiates scanning for programmer by set parameters There is same activity as at start the control program The command clears a list of default devices without the current device if the new selected programmer supports this one This setting is saved to disk by command Options Save options Programmer Refind programmer This m
38. cursor keys A list of manufacturers and devices will then be displayed Device can be selected by double clicking the line on which the device is on or by entering manufacturer name and or device number in a search box use a key lt Space gt as a separation character and press lt Enters gt or click OK button Press lt Esc gt or Cancel at any time to cancel device selection without affecting the currently selected device Selected device is automatically saved to the buffer of default devices max 20 devices This buffer is accessible with Device Select from default devices command If you wish to display additional information about the current device use the lt Ctrl F1 gt key This command displays the size of the device organization programming algorithm and a list of programmers including auxiliary modules that support this device Package and other general information about the selected device is also available Select device Only selected manufacturer This window displays the desired device by manufacturer First select a required manufacturer in Manufacturer box using mouse or cursor keys Select the Device by double clicking the line the desired device is on or by entering device number in the search box use a key lt Space gt as a separation character and press lt Enter gt or click OK button Press lt Esc gt or click Cancel at any time to cancel device selection without affecting the currently sel
39. d disconnecting sequence is irrelevant Protection circuits on all programmer inputs keep it safe But for the safety of your PC we recommend the above sequence Using the USB port In this case order of connecting USB cable and power supply to programmer is irrelevant 16 Dataman 48Pro Problems related to the Dataman 48Pro gt PC connection If you have any problems with Dataman 48Pro PC connection see section Common notes please Manipulation with the programmed device Select the device first then insert it into the ZIF socket Note that the ZIF socket is open with the lever up and closed with the lever down The correct orientation of the device is shown on the picture near the ZIF socket on the programmer s cover The programmed device can be removed from the socket when the BUSY LED turns off Note Programmer s protection electronics protect the target device and the programmer itself against either short or long term power failures However it is not possible to guarantee the integrity of the target device due to incorrect user selected programming parameters Do not remove the target device from the ZIF socket when the BUSY LED is on In system serial programming by Dataman 48Pro For general definition recommendation and direction about ISP see section Common notes ISP please Description of Dataman 48Pro ISP connector 2m AM 6 8107 La ga 58 7 ga Front view of the ISP connector Depen
40. d from a device onto a specified file The file format of saved file can be chosen from supported formats list box The Buffer start and Buffer end addresses can also be specified selecting the part of the buffer to save to the file Supported file formats now are binary MOTOROLA MOS Technology Tektronix Intel extended HEX ASCII space JEDEC and POF If the checkbox Swap bytes is displayed the user can activate the function of swapping bytes within 16bit words or 2 byte words during writing to file This feature is useful especially when saving files with Motorola representation of byte order in file big endian Standard save file operation is using little endian byte order The reserved key lt F2 gt will bring out this menu from any menu and any time File Load project This option is used for loading the project file which contains device configuration buffer data saved and user interface configuration The standard dialog Load project contains additional window Project description placed at the bottom of dialog This window is for displaying information about the currently selected project file Project information consists of e manufacturer and name of the first device selected in the project e date and time of project creation 40 Sofiware e user written description of project it can be arbitrary text usually author of project and some notes Note for projects with serialization turned on Seriali
41. d mode Protected mode is special mode of program When program is in Protected mode there are disabled program operation and commands that can modify buffer or device settings Protected mode is used for prevent operator from modify buffer or device settings due to insignificance Protected mode is suitable for the programming of a large amount of the same type of devices There are two ways how to switch program to Protected mode 1 by using menu command Options Protected mode This command displays password dialog User has to enter password twice to confirm the password is correct After password confirmation program switches to Protected mode The entered password is then used to switch off Protected mode 2 by reading project that was previously saved in Protected mode For details see File Save project gkang aaa a aaa 80 Software To switch program from Protected mode to normal mode use the menu command Options Normal mode The Password required dialog appears User has to enter the same password as the password entered during switch to Protected mode Other way to cancel Protected mode of program is closing of program because program Protected mode is active until program is closed The next program start will be to Normal standard mode the only exception is case of project loaded by command line parameter name of project and the project was saved in Protected mode Options Save options This co
42. ding on the device you want to program the specification of ISP connector pins may change You can find it in the control SW for the programmer PG4UW menu Device Device Info Ctrl F1 Please be aware that the ISP programming option of a given device must be selected This is indicated by a ISP suffix after the name of selected device For additional ISP information please refer to the device manufacturer 17 iyi Hilt Note Pin no 1 is indicated by a triangle on ISP cable connector Dataman 48Pro ISP cable Warnings e When you use Dataman 48Pro as ISP programmer do not insert device into ZIF socket e When you program devices into ZIF socket do not insert ISP cable to ISP connector Use only attached ISP cable When you use another ISP cable other material length programming may be unreliable Dataman 48Pro can supply programming voltage pin 1 of ISP connector and target system voltage pin 5 of ISP connector with some limitations see Technical specification ISP connector but target system should not supply voltage to the Dataman 48Pro Dataman 48Pro applies programming voltage to the target device If the programming voltage is different than expected the Dataman 48Pro will abort the operation Note H L read Dataman 48Pro driver C1 H L read driver R1 in programmer pin of ISP connector R2 PU PD driver in programmer Selftest and calibration If you feel that your programmer does
43. e end of this form We may need detailed data sheets of your target device and if possible samples The samples will be returned to you after we include your target device in a new version of PG4UW Note See also AlgOR service in Appendix C in this manual You may find the Device Problem Report form e in Appendix A of this manual e at our Internet site www dataman com 94 Troubleshooting and warranty Warranty terms The manufacturer Dataman Programmers Ltd gives a guarantee on failure free operating of the programmer and all its parts materials and workmanship for three year Dataman 48Pro and Dataman 40Pro from the date of purchase This warranty is limited to 25 000 cycles on DIL ZIF socket or 10 000 cycles on other ZIF sockets If the product is diagnosed as defective Dataman Programmers Lid or the authorized repair center will repair or replace defective parts at no charge Parts used for replacement and or whole programmer are warranted only for the reminder of the original warranty period For repair within the warranty period the customer must prove the date of purchase This warranty terms are valid for customers who purchase a programmer directly from Dataman company The warranty conditions of Dataman sellers may differ depending on the target country law system or Dataman seller s warranty policy The warranty does not apply to products that are of wear and tear or mechanically damaged Equally the warra
44. e use black ink a good pen and large letters easily to read Then call your local dealer or Dataman s customer support center phone number in the control program menu Help About Please keep your manual the programmer and the completed DEVICE PROBLEM REPORT form just 93 yi faxed available so that you can respond quickly to our questions e If your programmer is diagnosed as defective consult your local dealer or Dataman about the pertinent repair center in your country Please carefully include the following items in the package e defective product e completed DEVICE PROBLEM REPORT form e photocopy of a dated proof of purchase Without all these items we cannot admit your programmer to repair Note You may find the DEVICE PROBLEM REPORT form e in Appendix A of this manual e at our Internet site www dataman com If you have an unsupported target device If you need to operate on a target device not supported by the control program for programmer please do not despair and follow the next steps e Look in the device list of the latest version of the control program on our Internet site section Device List file corresponded to your programmer Your new target device might already be included in this version If yes download the file PG4UWARC exe and install the new version of the control program e Contact Dataman direct filling up a Device Problem Report form following the instructions at th
45. ecommended circuits e Purpose of D1 diode is to protect the target circuit against a higher voltage which is provided by ISP programmer e If your target board supply differs from mentioned 5V choose please the Zener diode D1 voltage according to this supply voltage e We recommend to use resistors R1 R2 R3 to separate the target device from target system If pins needed for ISP programming are inputs in target system then separation by resistors is sufficient and resistors make a low pass filter A 88 Common notes too If pins are outputs then use of resistors saves a programming time Of course the isolation resistors R1 R2 R3 can be replaced by switches or jumpers if necessary In that case during the ISP programming of target device the switches jumpers must be open But the using of switches jumpers adds a next manipulation time to programming procedure Other Attention to multitasking OS s Windows 95 98 Me NT 2000 XP There is needful for regular running of control program for any Dataman programmer that printer port on which is programmer connected must be reserved for this programmer only Otherwise any other program must not simultaneously to use or any way to modify this printer port PG4UW SW can handle all modes of LPT port full IEEE 1284 support thus you don t need to configure LPT port for connection of Dataman programmers Please don t move Info window during BUSY LED is on watching
46. ected device The selected device is automatically saved to buffer of default devices max 20 devices This buffer is accessible with Device Select from default devices command If you wish display additional information about the current device use an lt Ctrl F1 gt key This command displays the size of device organization programming algorithm and a list of _ _ SSSS S S __E__ _ _____ ___SSaz5 50 Software programmers including auxiliary modules that supports this device Package and other general information about the device is also available Device Select EPROM Flash by ID Use this command to autoselect a EPROM or Flash by reading the device ID The programmer can automatically identify certain devices by reading the manufacturer and the device ID that are burnt into the chip This only applies to EPROM or Flash that supports this feature If the device does not support a chip ID and manufacturer s ID a message will be displayed indicating this as an unknown or not supported device If more devices with identical chip ID and manufacturer s ID were detected the list of these devices will be displayed A corresponding device can be chosen from this list by selecting its number or manufacturer name and press lt Enters gt or click OK button Press a key lt Esc gt or click Cancel button at any time to cancel device selection without affecting the currently selected device Warning The control p
47. eloads initial value to Count down Device Device options Associated file This command is used for associating a file with the current device This is a file which can be automatic loaded to the buffer after a device is selected You can edit the associated file name in the file name box full pathname is required If enabled the control program checks the present of this file You can save both settings i e associated file and enabling of automatic load of this file to disk by command File Exit and save Device Device options Special options The special terms used here are exactly the terms used by manufacturer of respective chip Please read the documentation to the chip you want to program for explanation of all used terms Device Blank check This command performs a blank check on a device or part of a device if possible The control program reports the result of this action by a message to the INFO window The menu command Device Device options Operation options allows the setting of parameters related to blank check device operations 65 l N pilt Device Read This command allows reading the entire device or part of it into the buffer The control program displays a message in the INFO window when finished The menu command Device Device options Operation options allows the setting of parameters related to the read device operation Setting the option Verify data after reading in this menu
48. enu command is used to reestablish communication withthe currently selected programmer To select other type of programmer programmer communication parameters and to establish communication with newly selected programmer use the menu option Programmer Find programmer Programmer Handler In dialog box Handler the Handler type and Handler communication parameters can be set A Handler is an external device requiring special control of device related operations When no Handler is selected the default state device operations are controlled directly by user Otherwise the handler mode of operation is enabled and device operations are controlled automatically in co operation with the Handler _ _ E E SE 73 Hilt Dialog Handler contains following items Selected Handler select wished Handler type Search at port select a COM port which will be scanned for a requested Handler Pressing key lt Enter gt or button OK initiates scanning for Handler by set parameters If selected Handler type is None no Handler scanning will be processed Current Handler settings are saved to configuration file by command Options Save options or when control program is closed Handler is not available for sale Programmer Module options This option is used for multiple socket programmers for defining MASTER socket and activity of each socket MASTER socket group box allows user to set socket which is prefere
49. esigner ISDATA etc PC system requirements See section Introduction PC requirements GENERAL e operating voltage 15 18V DC max 1A e power consumption max 12W active about 2W inactive e dimensions 160x190x42 mm 6 3x7 5x1 7 inch e weight without external adapter 900g 2lbs e temperature 5 C 40 C 41 F 104 F e humidity 20 80 non condensing Package included e Dataman 48Pro programmer e connection cable PC programmer LPT port e connection cable PC programmer USB port e ISP cable e diagnostic POD for selftest e anti dust cover for ZIF socket e switching power adapter 100 240V AC 15V DC 1A e user manual e software e registration card e transport case Additional services e AlgOR e free technical support phone fax e mail e free lifetime software update via Web site 23 Dataman 40Pro Powen DATA AA AMAT AN NI A Se Mol U coco ERROR ADVANCED UNIVERSAL PRC GRAMMER www YES 24 Dataman 40Pro Introduction Dataman 40Pro is the next member of the new generation of Windows 95 98 Me NT 2000 XP based universal programmers This programmer is built to meet the demands of development labs and field engineers for a fast reliable and versatile programming Dataman 40Pro is a small fast and powerful programmer Using the built in in circuit serial programming ISP connector the programmer is capable of in circuit programming Dataman
50. et programmer Help Supported programmers This command displays information about programmers where supported this program Help Device list current programmer This command makes a list of all devices supported by current name of current programmer the device list is generated for Help Device list all programmers This command makes device lists for all supported abbreviated name of programmers the device lists are generated for Note The control program loses all information about current device after this command is executed Reselect wished device again by any of select methods in menu DEVICE Help Device list cross reference This command makes cross reference list of all devices supported by all programmers available on market and supported by this control program The resulting list is in HTML format and consists of following files one main HTML file TOP_DEV htm with supported device manufacturers listed partial HTML files with list of supported devices for each device manufacturer Main HTML file is placed to directory where this control program for programmers is located 82 Software Partial HTML files are placed to subdirectory DEV_HTML placed to the directory where control program for programmers is located About When you choose the Info command from the menu a window appears showing copyright and version information 83 Common notes 84 Common notes Softw
51. etting disables current setting of Erase buffer before loading option in menu Options General options at tab Hex file options If the checkbox Swap bytes is displayed the user can activate the function of swapping bytes within 16bit words or 2 byte words during the reading of a file This feature is useful especially when loading files with Motorola representation of byte order in file big endian Standard file loading uses little endian byte order Note Big endian and little endian are terms that describe the order in which a sequence of bytes are stored in computer memory Big endian is an order in which the big end most significant value in the sequence is stored first at the lowest storage address Little endian is an order in which the little end least significant value in the sequence is stored first For example in a big endian computer the two bytes required for a 39 mnt LUNI the hexadecimal number 4F52 would be stored starting at storage address 1000H as 4FH is stored at address 1000H and 52H will be at address 1001H In a little endian system it would be stored as 52H at address 1000H and 4FH at address 1001H Number 4F52H is stored in memory Address Big endian Little endian system system 1000H 4FH 52H 1001H 52H 4FH The reserved key lt F3 gt will bring out this menu from any menu and any time File Save This command saves data in the buffer which has been created modified or rea
52. g box a Ng Ng 90 Common notes that informs the user that a device data base is being built or updated After these dialogs appear the Found New Hardware Wizard dialog box is displayed Select Install from a list or specific location Advanced and click Next to continue the installation STEP 2 Make sure that Search for the best driver is selected Select Search removable media and deselect Include this location in the search Click Next STEP 2A During the install a dialog will pop up stating The software you are installing for this hardware has not passed Windows Logo testing Click Continue Anyway STEP 3 The Completing the Found New Hardware Wizard will appear once the programmer has been installed Click Finish to end the USB installation 91 Troubleshooting and warranty 92 Troubleshooting and warranty Troubleshooting We really want you to enjoy our product Nevertheless problems can occur In such cases please follow the instructions below elt might be your mistake in properly operating the programmer or its control program PG4UW e Please read carefully all the enclosed documentation again Probably you will find the needed answer right away eTry to install programmer and PG4UW on another computer If your system works normally on the other computer you might have a problem with the first one PC Compare differences between both computers e Ask your in ho
53. grammer checks all pins of the programmed chip if have proper connection to the ZIF e 52 Software socket continuity test The programmer is able to identify the wrong contact misinserted chip and also partially backinserted chip check ID bytes default ENABLE If enabled the programmer checks the electronic ID of the programmed chip Note 1 Some old chips don t carry electronic ID Note 2 In some special cases several microcontrollers don t provide ID if copy protection feature in the chip is set even if device ID check setting in control program is set to Enable group Command execution blank check before programming default DISABLE erase before programming default DISABLE verify after reading default ENABLE verify ONCE TWICE verify options nominal VCC 5 nominal VCC 10 VCCmin VCCmax group ISP Target Supply Parameters Enable target system power supply enables supplying of target system from programmer Supply voltage for target system is switched on before action with programmed device and is switched off after action finished If Keep ISP signals at defined level after operation is enabled then programmer will switch off supply voltage after pull up pull down resistors are deactivated Voltage supply voltage for target system Max current maximum current consumption of powered target system Voltage rise time determines skew rate of rising edge of target supply voltage
54. h programming may become unreliable e Dataman 40Pro can only supply programming voltage Refer to ISP specs by device manufacturer for additional information e Dataman 40Pro apply programming voltage to target device and checks his value target system can modify programming voltage If the programming voltage is different as expected no action with target device will be executed Note H L read Dataman 40Pro driver 29 C1 H L read driver R1 in programmer pin of ISP connector R2 PU PD driver in programmer Selftest and calibration If you feel that your programmer does not work properly please run the programmer selftest using the Diagnostic POD The Diagnostic POD is included with the standard package For optimal results we recommend you run the programmer selftest and calibration every 6 months See instructions for selftest in the Diagnostics menu of PG4UW Technical specification HARDWARE Programmer e two D A converters for VCCP and VPP controllable rise and fall time e VCCP range 0 7V 350mA VPP range 0 25V 200mA USB 2 0 1 1 compatible interface autocalibration selftest capability ZIF socket pindriver e 40 pin DIL ZIF Zero Insertion Force socket accepts both 300 600 mil devices up to 40 pins e pindriver 40 TTL pindrivers universal GND VCC VPP pindriver A 30 Dataman 40Pro e FPGA based TTL driver provides H L CLK pull up pull down on all pindriver pins level H se
55. h one way insertion lock e 6 TTL pindrivers provides H L CLK pull up pull down level H selectable from 1 8V up to 5V to handle all low voltage including devices e 1x VCCP voltage range 2V 7V 100mA and 1x VPP voltage range 2V 25V 50mA e programmed chip voltage VCCP with both source sink capability and voltage sense e target system supply voltage range 2V 6V 250mA DEVICE SUPPORT Programmer in ZIF socket e EPROM NMOS CMOS 2708 27xxx and 27Cxxx series with 8 16 bit data width full support for LV series e EEPROM NMOS CMOS 28xxx 28Cxxx 27EExxx series with 8 16 bit data width e Flash EPROM 28Fxxx 29Cxxx 29Fxxx 29BVxxx 29LVxxx 29Wxxx 49Fxxx series from 256Kbit to 32Mbit with 8 16 bit data width full support for LV series e Serial E E PROM 24Cxxx 24Fxxx 25Cxxx 45Dxxx 59Cxxx 25F xxx 25Pxxx 85xxx 93Cxxx NVM3060 MDAxxx series full support for LV series e Configuration EE PROM XCFxxx XC17xxxx XC18Vxxx EPCxxx AT17xxx 37LVxx e 1 Wire E E PROM DS1xxx DS2xxx e PROM AMD Harris National Philips Signetics Tesla TI eNV RAM Dallas DSxxx SGS Inmos MKxxx SIMTEK STKxxx XICOR 2xxx ZMD U63x series e PLD Altera MAX 3000A MAX 7000A MAX 7000B MAX 7000S MAX7000AE e PLD Lattice ispGAL22V10x ispLSI1xxx ispLSIl1xxxEA ispLSI2xxx ispLSI2xxxA ispLSI2xxxE ispLSI2xxxV ispLSI2xxxVE ispLSl2xxxVL LC4xxxB C V ZC M4 xx xx M4A3 xx xx M4A5 xx xx M4LV xx xx e PLD Xilinx
56. his command loads the data from binary file from disk and it saves them into the part of memory reserved for an encryption security table File Save encryption table This command writes the content of the memory s part reserved for an encryption table into the file on the disk as a binary data File Exit without save The command deallocates heap cancels buffer on disk if exists and returns back to the operation system File Exit and save The command deallocates heap cancels buffer on the disk if exists Saves current setting of last 20 selected devices to disk and returns back to the operation system Buffer Menu Buffer is used for buffer manipulation block operation filling a part of buffer with string erasing checksum and of course editing and viewing with other items find and replace string printing Buffer View Edit This command is used to view view mode or edit edit mode data in the buffer for viewing in DUMP mode only Use the arrow keys to select the data for edit Data to be edited is signified by colour aa 43 pilt You can use lt F4 gt as the hot key also View Edit Buffer F1 display help of actual window F2 fill block causes filling selected block of buffer by requested hex or ASCII string Sets start and end block for filling and requested hex or ASCII string Ctrl F2 erase buffer with specified blank
57. ice If the buffer organization is byte org x8 the Serialization Address will be byte address If the buffer organization is wider than byte e g 16 bit words x16 the Serialization Address will be word address Device Device options Serialization From file mode Using the From file method serial values are read from the user specified input file and written to buffer on address specified in input file There are two user options File name and Start label File name File name option specifies the file name from which serial addresses and values will be read The input file for From file serialization must have special format which is described in From file serialization file format below Start label Start label defines the start label in input file From defined start label starts reading of serial values from input file From file serialization file format From file serialization input file includes addresses and arrays of bytes defining buffer addresses and data to write to buffer Input file has text type format which structure is label 1 addr byte0 byte 1 byten labeln addr byted byte 1 bytem addr byte0 byte 1 bytek l 61 LUNI basic part optional part Comment meaning is basic part Basic part defines buffer address and array of bytes to write to buffer Basic part must be always defined after label in line optional part Optional part defines the second array of bytes
58. ing LPT port Turn off your PC and programmer Install the parallel cable included with your Dataman 48Pro programmer package to a free printer port on your PC Connect the cable to the programmer and then to the PC Make sure to tighten the connectors down with the thumb screws to their respective ports It may be uncomfortable to switch between a printer cable and programmer cable however it is not recommended to operate the Dataman 48Pro programmer through a printer switch However you can install a second multi I O controller in your computer thus obtaining a supplementary printer port such as LPT2 In this case your printer may remain on LPT1 while the programmer is on LPT2 Switch on the PC Plug in the power supply and then insert the mini DIN connector into the programmer s connector labelled 15VDC At this time all work result LEDs and POWER LED light up in succession and then switch off Once the POWER LED is illuminated the Dataman 48Pro programmer is ready for use Next run the control program for Dataman 48Pro Caution f you don t want to switch off your PC when connecting the Dataman 48Pro proceed as follows e When connecting the programmer to the PC FIRST insert the communications cable and THEN the power supply connector e When disconnecting the programmer from the PC FIRST disconnect the power supply connector and THEN the communication cable From the programmers point of view the connecting an
59. lectable from 1 8 V up to 5V e in circuit serial programming ISP capability included e continuity test each pin is tested before every programming operation ISP connector e 10 pin male type with missinsertion lock e 6 TTL pindrivers provides H L CLK pull up pull down level H selectable from 1 8V up to 5V to handle all low voltage including devices e 1x VCCP voltage range 2V 7V 100mA and 1x VPP voltage range 2V 25V 50mA e programmed chip voltage VCCP with both source sink capability and voltage sense DEVICE SUPPORT Programmer in ZIF socket e EPROM NMOS CMOS 27xxx and 27Cxxx series with 8 16 bit data width full support of LV series 1 2 EEPROM NMOS CMOS 28xxx 28Cxxx 27EExxx series with 8 16 bit data width full support of LV series 1 2 Flash EPROM 28Fxxx 29Cxxx 29Fxxx 29BVxxx 29LVxxx 29Wxxx 49Fxxx series with 8 16 bit data width full support of LV series 1 2 Serial E E PROM 24Cxxx 24Fxxx 25Cxxx 45Dxxx 59Cxxx 25F Xxx 25Pxxx 85xxx 93Cxxx full support for LV series 1 Configuration EE PROM XCFxxx 37LVxx XC17xxxx EPCxxx AT17xxx LV series including NV RAM Dallas DSxxx SGS Inmos MKxxx SIMTEK STKxxx XICOR 2xxx ZMD U63x series PLD series Atmel AMD Vantis Cypress ICT Lattice NS 1 microcontrollers 51 series 87Cxxx 87LVxx 89Cxxx 89Sxxx 89LVxxx LPC series from Atmel Atmel W amp M Intel Philips SST Winbond 1 2 microcontrollers Atmel AVR A
60. luded in programmer delivery package Be sure that pins are interconnected properly i e 1 1 2 2 6 6 3 Run selftest of ISP connector in PG4UW Programmer Selftest ISP connector Sequence for testing 10 pins ISP connector 1 Insert Diagnostic POD for ISP connectors into ZIF socket of the programmer Diagnostic POD must be inserted as 40 pins device 2 Interconnect 10 pins connector of Diagnostic POD with an ISP connector of the programmer with an ISP cable included in delivery programmer package Be sure that pins are interconnected properly i e 1 1 2 2 10 10 3 Run selftest of ISP connector in PG4UW Programmer Selftest ISP connector We recommend run this test every 6 months Programmer Calibration test Command executes test of programmer s calibration values Programmer Create diagnostic report Create Diagnostic report is used for writing more specific diagnostic information to the Log window and consequently 76 Software copy Log window content to clipboard The Log window content can be placed from clipboard to any text editor Diagnostic reports are useful when error occurs and have to be documented Diagnostic reports are useful when communicating with programmer or device manufacturers Options The Options menu contains commands that let you view and change various default settings Options General options General options dialog allows users to control following program options
61. mmand saves all settings that are currently supported for saving even if auto save is turned off Following options are saved options under the Options menu ten last selected devices file history main program window position and size Help Pressing the lt F1 gt key accesses the Help When you are selecting menu item and press lt F1 gt you access context sensitive help If PG4UW is executing an operation with the programmer lt F1 gt generates no response The following Help items are highlighted e words describing the keys referred to by the current Help e all other significant words e current cross references click on this cross reference to obtain further information Since the Help system is continuously updated together with the control program it may contain information not included in this manual Detailed information on individual menu commands can be found in the integrated on line Help Note nformation provided in this manual is intended to be accurate at the moment of release but we continuously improve all our products Please consult manual on www dataman com 81 l corel Hilt Help Supported devices This command displays list of all devices supported by at least one type of all supported programmers It is useful especially when user wants to find any device supported by at least one type of programmers Prefix g_ before name of device means the device is supported by multi sock
62. n a en baa aaa Naah ETE AT 38 E E A E a O 43 DGVIGC PE E T a E T A ETET 48 Programme spiana arii a 72 Options hati in ee AE TORE 77 a a ga Ba AKA A aa TA EN a E EN Nn 81 COMMON NOtES saa kan saa a e aa Ga ANGGA EEN Aa a aa a Kak 84 OINA ERRA aaa NAN ng aa akh Gb A aa EE aa aana pena pa aaa d 85 Hardware ran ie aaa agaran a Ga aben pu wadana AN a AD Ka a Bean ga an 86 ISP In System Programming 0aaanaaaeaae anana ananem nana nane 87 Other Sasa Aa Tk in A GA ag akan aa a a a dag Aa gg a GEE 89 Troubleshooting and warranty aasssoesenaeesanewna nenen nnn nawan nananen 92 Troubleshooting sas ask aaa kra ak ANG San Nan A GA Dena na ENG Peang Dang Ki kabak 93 If you have an unsupported target device 0arannenaann ane 94 Warranty terms APPONAX sccseseesteensceeseersseeserseeentenseceens Appendix A Device Problem Report form 0aaannanaenanane 97 Appendix B AIQOR service 0 0 ce eeeeceeeeeereeteeteeeeeeaeeereeaeeneeeaeeaes 98 Appendix C registration Card sesser 100 Conventions used in the manual References to the control program functions are in bold e g Load File Device etc References to control keys are written in brackets lt gt e g lt F1 gt Terminology used in the manual Device any kind of programmable integrated circuits or programmable devices ZIF socket Zero Insertion Force socket used for insertion of target device Buffer part of memory or
63. n of possible reasons disconnected programmer bad connection power supply failure incompatible printer port Eliminate the error source and press any key If error condition still exists the program resumes its operation in the demo mode and access to the programmer is not possible If you cannot find the cause of the error follow the instructions in Troubleshooting section In addition the control program checks communication with programmer prior to any operation with the programmed device Description of the user screen program PG4UW PCAUW universal control program for Dataman programmers 2 14 Dbeta 097 05 2005 Fie Buiter Deke Progammer Options Hep B 4SS 2 FF ak rah ak s nitian ew anga s control program PG4DW Windows a a Log window Header bar the name copyright statement and version of the PG4UW control program Menu bar list of basic functions Filename information on the currently loaded file in buffer 37 pilt information about the status of the programmer and PG4UW organization size start and end addresses of the target device buffer Programmer window Addresses window and file Device window all relevant information about the current target device Help bar a brief description of selected command Menu selection is carried out in the normal GUI fashion either by cursor moving plus pressing lt Enter gt or by typing the highlighted letter in the wanted menu or
64. names can contain all characters except T and T The label names are analysed as non case sensitive i e character a is same as A b is same as B etc All address and byte number values in input file are hexadecimal e Allowed address value size is from 1 to 4 bytes Allowed size of data arrays in one line is in range from 1 to 64 bytes When there are two data arrays in one line the sum of their size in bytes can be maximally 80 bytes Be careful to set correct addresses Address must be defined inside device start and device end address range In case of address out of range warning window appears and serialization is set to disabled None Address for Serialization is always assigned to actual device organization and buffer organization that control program is using for current device If the buffer organization is byte org x8 the Serialization Address will be byte address If the buffer organization is wider than byte e g 16 bit words x16 the Serialization Address will be word address Example nav 1 A7890 78 89 56 02 AB CD comment nav2 A7890 02 02 04 06 08 0A nav3 A7890 08 09 OA OB AO CO comment2 nav4 A7890 68 87 50 02 0B 8D nav5 A7890 A8 88 59 02 AB 7D snext line contains also second definition nav6 A7890 18 29 36 42 5B 6D FFFF6 44 11 22 33 99 88 77 66 55 16 this is last line end of file In the example file six serial values with labels nav 1 ynav2
65. nd verify 38sec AM29DL640 programming and verify 76 sec AT45D081 programming and verify 43 sec AT89C51RD2 programming and verify 15 sec PIC18F452 programming and verify 4 sec System P4 2 4GHz USB 2 0 Windows XP SOFTWARE e Algorithms only manufacturer approved or certified algorithms are used Custom algorithms are available at additional cost e Algorithm updates software updates are available approx every 2 weeks free of charge e Main features revision history session logging on line help device and algorithm information Device operations e standard e intelligent device selection by device type manufacturer or typed fragment of part name automatic ID based selection of EPROM Flash EPROM blank check read verify program erase configuration and security bit program illegal bit test e checksum e security e insertion test reverse insertion check e contact check e ID byte check e special e production mode automatic start immediately after device insertion e auto device serial number increment 22 Dataman 48Pro e statistic e count down mode Buffer operations e view edit find replace e fill copy move byte swap word dword split e checksum byte word e print Supported file formats e unformatted raw binary e HEX Intel Intel EXT Motorola S record MOS Exormax Tektronix ASCll space HEX e Altera POF JEDEC ver 3 0 A e g from ABEL CUPL PALASM TANGO PLD OrCAD PLD PLD D
66. nibbles of BCD numbers Select the base in Style options before entering numbers of serial start value and step Save to buffer Save to buffer option specifies the serial value byte order to write to buffer This option is used for Bin S N mode for ASCII mode it has no effect Two options are available e LSByte first used by Intel processors will place the Least Significant Byte of serial number to the lowest address in buffer e MSByte first used by Motorola processors will place the Most Significant Byte first to the lowest address in buffer Split serial number at every N byte s The option allows dividing serial number into individual bytes and placing the bytes at each Nth address of buffer This feature is particularly useful for example for Microchip PIC devices when the device serial number can be the part of program memory as group of RETLW instructions The example of using serial number split is listed in section Examples bellow as example number 2 Examples 1 Write serial numbers to AT29C040 devices at address 7FFFAH size of serial number is 4 bytes start value is 16000000H incremental step is 1 the serial number form is binary and least significant byte is placed at the lower address of serial number in device To make above described serialization following settings have to be set in Serialization dialog Mode Incremental mode S N size 4 bytes S N mode Bin SSSSSSSS ___ _ _
67. ntially used for device reading operation Enable Disable socket checkbox array allows user to set enabling and disabling of each socket individually Disabled sockets are ignored for any device operation Programmer Automatic YES This command is used for setting Automatic YES mode In this mode you just put a device into the ZIF socket and a last operation will be repeated automatically Program automatically detects an insertion of a new device and runs last executed operation without pressing any key or button An insertion of device into ZIF is displayed on the screen Repeat last operation is cancelled by pressing the key lt ESC gt during waiting for insert remove a device to from ZIF After a device operation is executed one of the OK or ERROR status LEDs on the programmer will light depending on the result of an operation and the BUSY LED will blinking If the program detects removal of a device then status LED will switched off but the BUSY LED will still blinking to indicate readiness of the program to repeat last operation with new device After the program determines that a new device is in the ZIF socket the BUSY LED will goes to light continually The programmer will wait for the device to be properly inserted ZIP socket closed If this operations times out the program will light the ERROR LED After a new device is inserted correctly the program will switch off all status LEDs except BUSY and will start an ope
68. nty does not apply to products opened and or repaired and or altered by personnel not authorized by Dataman or to products that have been misused abused accidentated or that were improperly installed For unwarrantable repairs you will be billed according to the costs of replacement materials service time and freight Dataman or its distributors will determine whether the defective product should be repaired or replaced and judge whether or not the warranty applies Please also see Troubleshooting section Manufacturer PA Dataman Programmers Ltd Station Road Maiden Newton Dorset DT2 0AE United Kingdom T 44 0 1300 320719 www dataman com sales dataman com 95 Appendix Appendix Appendix A Device Problem Report form Visit please the www dataman com site and use the Problem Report form Support section if occurred any problem during work with programmable device and Dataman programmers If you haven t access to Internet please make a copy of this page to A4 DEVICE PROBLEM REPORT Subject title of problem Date Customer Customer name Distributor name Address Date of purchasing Contact person and e mail Date of sending registration card Information about product Programmer type modification Mains supply voltage Vv Serial number Version of control program PG4UW Configuration modules converters Power supply unit From delivery Other output V and A Inf
69. o el lelelelelelelele If you find any discrepancy with respective parts list and or if any of these items are damaged please contact your distributor immediately PC requirements Minimal PC requirements e PC Pentium 166 e 32MB RAM e one CD drive e HDD 40 MB free space e operating system Windows 95 98 Me NT 2000 XP e USB port 1 1 or later e one parallel LPT port for dedicated use Dataman 48Pro parallel mode Recommended PC requirements e Pentium PC III 800 MHz or higher e 256 MB free RAM e one CD drive e HDD 50 MB free space e operating system Windows XP eLPT printer port supporting EPP ECP modes for programmers connected via LPT port e USB port ver 1 1 or later for programmers connected via USB port Note For convenience we suggest that you use a supplementary multi I O card to provide an additional printer port LPT2 for example in order to avoid sharing the same LPT port between printer and programmer gt L _ _ 8 Quick Start Quick Start ue Installing programmer hardware e switch off the PC and programmer e connect the communication port of programmer to a printer port of the PC using the supplied cable e switch on the PC e connect the power supply adapter to the programmer Installing the programmer software Run the installation program from the CD Setup exe and follow the on screen instructions Please see our website for the late
70. oad a recently used file When you use a file it is added to the Reload file list Files are listed in order depending on time of use of them Lastly used files are listed before files used far off To Reload a file 1 From the File menu choose Reload file 2 List of lastly used files is displayed Click the file you want to reload Note When reloading a file the file format is used by which the file was lastly loaded saved File Reload project Choose this option to reload a recently used project When you use a project it is added to the Reload project list Projects are listed in order depending on time of use of them Lastly used projects are listed before projects used far off To Reload a project 1 From the File menu choose Reload project 2 List of lastly used projects is displayed Click the project you want to reload a 42 Sofiware File Project options This option is used to display edit project options of the actually loaded project Project options means basic description of project including following project data e device name and manufacturer e project creation date e user defined project description arbitrary text e g project author and other text data for more detailed project description User can directly edit user defined project description only Device name manufacturer project date and program version are generated automatically by program File Load encryption table T
71. occur always or randomly AlwaysRandomly Does programmer work well with other PCs Yes No Nottested e Whatis the results of programmer selftest if available OK Eror Please list the step by step description of all activities that invokes a problem Please make your problem description as specific as possible you can increase speed and chance to resolve a problem Please mention any step that is known to cause the problem or any step that may prevent the problem Please copy all error reports too full content of LOG window is preferable We recommended use command Diagnostics Create diagnostic report Your comments and descriptions of expectations are welcomed It s best if you can send us the actual device with which the problem occurs Use a separate sheet if necessary Note e if you haven t installed the latest version of control program you can get it from www dataman com page Download section It is very important to have latest version of software because e itis possible the problem you have is already solved by software update e we don t save older version of software If ask you to please perform next steps software may not behave in the same way as the latest one as used by us e in the case of sending samples please attach to the package this declaration for customs Free sample s not for commercial sale Value for customs purposes only 10US your version of A 97 l Mi hile Why is it importan
72. odules Using the built in in circuit serial programming ISP connector the programmer is able to program in circuit Dataman 48Pro isn t only a programmer but also a tester of TTL CMOS logic ICs and memories Furthermore it allows generating user definable test pattern sequences Dataman 48Pro provides a very competitive price and excellent hardware design for reliable programming It is the most cost effective programmer in its class Dataman 48Pro provides very fast programming due to high speed FPGA driven hardware and execution of time critical routines inside the programmer Dataman 48Pro_ interfaces with the IBM PC Pentium compatible or higher portable or desktop personal computers through USB 2 0 port or any standard parallel printer port Programmer also supports IEEE1284 ECP EPP high speed parallel port Support of USB LPT port connection gives you choice to connect the Dataman 48Pro programmer to any PC from latest notebook to an older desktop without USB port Dataman 48Pro has a FPGA based totally reconfigurable 48 powerful TTL pindrivers They provide H L pull_up pull_down and read capability for each pin on the socket Advanced pindrivers incorporate high quality and high speed circuitry to deliver signals without overshoot or ground bounce for all supported devices Pin drivers operate down to 1 8V so you ll be ready to program the full range of today s advanced low voltage devices Dataman 48Pro performs a
73. of programmers including auxiliary modules that supported this device Package and other general information about the current device are also available Select device All This window allows selecting the desired device from all devices supported by the programmer Supported devices are displayed in a list box Device can be selected by double clicking the line on which the device is on or by entering manufacturer name and or device number in a search box use a key lt Space gt as a separation character and press lt Enter gt or click OK button Press lt Esc gt or click Cancel at any time to cancel device selection without affecting the currently selected device The selected device is automatically saved to buffer of default devices max 20 devices This buffer is accessible with Device Select from default devices command 49 mm ni j na E If you wish display additional information about the current device use an lt Ctrl F1 gt key This command displays the size of the device organization programming algorithm and a list of programmers including auxiliary modules which supported this device You can find here Package and other general information about the selected device is also available Select device Only selected type This window allows selecting the desired device type First you must select a device type e g EPROM Prom PLD and device subtype e g 64Kx8 27512 using mouse or
74. ommonly used items group Addresses device start address default 0 device end address default device size 1 buffer start address default 0 Split default none This option allows to set special mode of buffer when programming or reading device Using split options is particularly useful when using 8 bit data memory devices in 16 bit or 32 bit applications Following table describes buffer to device and device to buffer data transfer Split type Device Buffer Address assignment None Device ADDR Buffer ADDR Even Device ADDR Buffer 2 ADDR Odd Device ADDR Buffer 1 2 ADDR 1 4 Device ADDR Buffer 4 ADDR 2 4 Device ADDR Buffer 1 4 ADDR 3 4 Device ADDR Buffer 2 4 ADDR 4 4 Device ADDR Buffer 3 4 ADDR Real addressing will be following all addresses are hexadecimal Split type Device addresses Buffer addresses None 00 01 02 03 04 05 00 01 02 03 04 05 Even 00 01 02 03 04 05 00 02 04 06 08 0A Odd 00 01 02 03 04 05 01 03 05 07 09 0B 1 4 00 01 02 03 04 05 00 04 08 OC 10 14 2 14 00 01 02 03 04 05 010509 0D 11 15 3 14 00 01 02 03 04 05 02 06 OA OE 12 16 4 4 00 01 02 03 04 05 03 07 OB OF 13 17 Terms explanation Access to device address ADDR Device ADDR Access to buffer Buffer ADDR ADDR value can be from zero to device size in bytes All addresses are byte oriented addresses is written as address ADDR is written as group Insertion test insertion test default ENABLE If enabled the pro
75. on in unidirectional mode Available executive command line parameters Prj lt file_name gt forces project load when program is starting or even if program is already running lt file_name gt means full or relative project file path and name Loadfile lt file_name gt forces file load when program is starting or even if program is already running lt file_name gt means full or A 85 pil relative path to file that has to be loaded file format is detected automatically Program switch forces start of Program device operation automatically when program is starting or even if program is already running also one of following optional switches can be used switch noquest forces start of device programming without question switch noanyquest forces start of device programming without question and after operation on device is completed program doesn t show Repeat operation dialog and goes directly into main program window Examples 1 Program 2 Program noquest 3 Program noanyquest Close this parameter has sense together with Program parameter only and makes program to close automatically after device programming is finished no matter if operation was successful or no Eprom_Flash_Autoselect xx forces automatic select EPROM or FLASH by ID when program is starting or even if program is already running xx means pins number of device in ZIF this time are valid 28 or 32 pins only and it is req
76. ontains following items From address This is a start address of the block selected for calculating checksums in the buffer Address is defined as Byte address To address This is the end address of block selected for calculating checksums in the buffer Address is defined as Byte address Insert checksum When selected the checksum will be written into the buffer see Calculate amp insert Insert at address This specifies an address within the buffer where the chosen checksum will be written see Calculate amp insert The Address can not be within the range specified by lt From address gt to lt To address gt Address is defined as Byte address Size This item is used for setting a size of chosen checksum result which will be written into the buffer The size of checksum result may be 8 byte or 16 word bits long If word size was selected whole checksum value will be written into the buffer Note f word size was selected a low byte of checksum value will be written on address specified in box Insert address and a high byte will be written on address incremented by one Calculate Start calculating checksums for selected block in the buffer No writes into the buffer are executed Calculate amp insert Start calculating checksums for selected block in the buffer and writes the chosen checksum into the buffer on address specified by Insert address Device The Device Menu includes functions for working wi
77. ormation about PC to which is the programmer is attached Manufacturer Type Desktop Notebook Processor speed LPT port location motherboard ISA card PCI card Operating system and version LPT port type standard ECP EPP 1284 Memory free memory LPT port setting SPP BIDIR EPP ECP Information about device with which you have the problem Device type full name prefix suffix including Package type plastic ceramic ceramic windowed Vendor logo All designation on the top Package DIL40 PLCC44 SOIC20 and on the bottom side of device Precedence rating in__ days in__ weeks in__ months How often you work with this devices still Y N sometimes Y N one shot Y N Number of programmed device approx __ pcs per year Samples are available Yes I m sending it attached Yes No Further questions e Did you have installed latest version of control program Yes No e Did you know thoroughly the features and correct behavior of programmer and programmed device Yes No e Is the socket of programmer or adapter free from dust and isn t out of life Yes No e Is the device with problem new or used New Used e Is the error reported for all of the tested devices Yes No haveonly one device e Is the error reported for devices with other date code Yes No Ihave only one batch e_ During which procedure is an error reported Read Program ID check Insertion test e Is the programmer successful in case of other types of devices Yes No e Does the error
78. ould result in a negative number Therefore be careful when selecting this value Language This page allows you to select another language for the user interface such as menus buttons dialogs information and messages It also allows the selection of help file in another language For language support a language definition file is required Sound Sound page allows the user to select the sound mode of the program Program generates sounds after some activities such as programming verifying reading etc Program generates sound when warning or error message is displayed User can now select sound from Windows system sound required installed sound card PC speaker or none sound In the panel Programmer internal speaker sound settings is possible to set sound options for some programmers with built in internal speaker Sound beeps are then generated from internal programmer speaker after each device operation for indicating device operation result good or bad result Log file e LL E _ z 78 Sofiware This options associates with using of Log window All reports for Log window can be written into the Log file too The Log file name is Report rep as default The control program creates this file with name and directory specified in Log file name edit box Following Log file options are available e No default content of Log window is not copied to Log file i e all reports will be displayed to Log
79. prefix DO_something then contact us OK Accept selected action with appropriate procedures which are marked Information Displays informations about Jam file You can preview NOTEs and source file in dialog Device according to Jam file file is made for a specific device Device name is found in Jam file in part NOTE identifier DEVICE Device name must be identical with name of the device selected in dialog Select device When devices are different software will indicate this situation by warning message during start of the Jam Player JAM file information dialog 69 Information Notes Source File Identifier Text CREATOR QUARTUS Il JAM COMPOSER 4 0 DATE 2004 03 22 DEVICE EPM70644E FILE c4_epm70644ELC44_10 pof TARGET 1 IDCODE 170640DD USERCODE FFFFFFFF CHECKSUM OOOEBCEC SAVE_DATA DEVICE_DATA SAVE_DATA_VARIABLES 0 412 413 425 A43 A92 A94 A95 A50 STAPL_VERSION JESD 1 JAM_VERSION ALG_VERSION Cancel Notes statements are used to store information about the Jam file The information stored in NOTE fields may include any type of documentation or attributes related to the particular Jam program Source file contains a program in Jam language Jam program consists of a sequence of statements Jam statement consists of a label which is optional an instruction and arguments and terminates with a semicolon Arguments may be literal constants variables or expressions resulting in the desired d
80. programmer without the diagnostic POD Programmer Selftest plus This command executes a selftest of the programmer using diagnostic POD which is included with the programmer We recommend running this test every 6 months Programmer Self test ISP connector This command executes a selftest of the ISP connector for the programmer using the diagnostic POD for ISP connectors Diagnostic POD for ISP connectors is necessary to use for testing 6 and 10 pin ISP connectors of programmers _ SSSSSSSS S S az0 75 ue Diagnostic POD for ISP is available as optional accessory for ISP capable programmers The order number 70 0208 Schematic of Diagnostic POD for ISP connector if you are in hurry Jl DIP40 to ZIF socket ZIF1 HRIA 47R an rA HRIB 47R ZIF3 2 HRIC 47R A ZIFS 37 ZIF6 5 36 ZIF7 6 35 n ZIFS 1 a HARTING 09185106324 N ZAE9 a SS 10 31 ZIF11 11 30 12 29 13 28 ie 14 27 a a 15 26 a 2 a 16 25 5 17 24 18 23 m 19 22 HARTING 09185066324 zy 2 Sequence for testing 6 pins ISP connector 1 Insert Diagnostic POD for ISP connectors into ZIF socket of the programmer Diagnostic POD must be inserted as 40 pins device 2 Interconnect 6 pins connector of Diagnostic POD with an ISP connector of the programmer with an ISP cable inc
81. ration with new device 74 Software This mode may be enabled or disabled by item Automatic YES mode If a new programmer is selected Options Find programmer this mode will be disabled Response time allows the user to set the time interval for new device detection Default is set standard interval If a socket adapter is used then it is recommended to set an elongated interval In Pins with capacitors bar may be entered a list of a pins interconnected by capacitors for example if a converter which have connected capacitor between VCC and GND is used which may makes problems at detecting insertion of a new device List of pins of device is in form pinA pinB pinC Example 4 6 17 In Device removal hold off time is the delay when the programmed device is removed and a new device is inserted into the programmer s ZIF socket This interval is in seconds and must be from 1 to 120 default value is 2 seconds In Device insertion complete time is the maximum time for all pins of the device to be properly inserted after the first pin s were detected so that the program does not report an insertion error This interval is in seconds and must be from 1 to 120 default value is 5 seconds This list is erased if a new device is selected by Device Select default or Device Select device This setting is saved to disk by command Options Save options Programmer Selftest This command executes a selftest of
82. ress Post Code City Country Phone Fax e mail Date of purchase Purchase from Complete please e what type of computer are you using Olntel OAMD OOther operating system OWindows 95 98 Me OWindows NT 2000 XP e how did you first hear about Dataman Qladvert Odealer other why did you choose this product Oprice Oquality Orecommendation Ofeatures please specify e comments 100
83. ring the load operation The rich featured autoincrement function enables users to assign individual serial numbers to each programmed device increments a serial number or read the serial numbers or any programmed device identification signatures from a file The software also provides information about the programmed device The drawings of all available packages are provided The software also provides explanation of chip labelling the meaning of prefixes and suffixes at the chips for each supported chip It is important to remember that in most cases new devices require only a software update due to the Dataman 48Pro universal programmer design With our prompt service new devices can be easily added Please contact us for details Advanced design including protection circuits original brand components and careful manufacturing allows us to provide a three year warranty on parts and labour for the Dataman 48Pro limited 25 000 cycle warranty on ZIF socket 14 Dataman 48Pro Dataman 48Pro elements 48 pin ZIF socket LED indicator power sleep LED indicators for work result Jack for connecting ESD wrist strap LPT connector for PC lt Dataman 48Pro communication cable USB connector for PC lt gt Dataman 48Pro communication cable Power switch Power supply connector ISP connector Power supply connector 15V DC 1A 15 gil Connecting Dataman 48Pro to the PC Us
84. rl Home End jump on start end current device Shift Home End jump on start end current buffer oe 44 Software Backspace move cursor one position left back Note characters 20H FFH mode ASCII and numbers 0 9 A F mode HEX immediately changes content of edit area Warning Editing of ASCII characters for word devices is disabled Print buffer This command allows writing the selected part of the buffer to a printer or file The program uses an external text editor in which the selected block of the bufferdata is displayed and then printed or saved By default the text editor is set to Notepad exe which is standard part of all versions of Windows The Print Buffer dialog box options are Block start Defines start address of selected block in buffer Block end Defines end address of selected block in buffer External editor This item defines the path and name of an external program which can be used as a text viewer By default it is set to Notepad exe which is standard in all versions of Windows The user can define any text editor for example Wordpad exe which is able to work with larger text files The user defined text editor can be used to print or save the selected block of bufferdata The external editor path and name is saved automatically to disk Find dialog box Enter the search string in either text or Ascii and choose lt Find gt to begin the search Direction box specifies which way you
85. rogram Multiple devices are possible to program and test via JTAG chain JTAG chain ISP VME More information on the website http www latticesemi com products devtools software isovme mbed index cfm In System Programmability Guidelines http www latticesemi com products technology isp_usage cfm 71 Software tools Lattice ispLEVER ispoVM System ISP Programming Software PAC Designer Software svf2vme utility converts a serial vector file to a VME file Device Device info The command provides additional information about the current device size of device organization programming algorithm and a list of programmers including auxiliary modules that supported this device You can find the package information part number description and full information for ISP implementation For example description of ISP connector pins for currently selected chip recommended target design around in circuit programmed chip A Device info 3 Common information ISP connection details Part number description Recommended target circuit design ISP connector target device target system reset circuit The reserved key lt Ctrl F1 gt is the HOT key Programmer Menu Programmer includes commands used for work with programmers Programmer Find programmer This menu is for programmer related operations This command contains following items Programmer Searches for an installed programmer The
86. rogram only support EPROM s and Flash with 28 and 32 pins at this time Any of programmers determines pins number automatically For other programmers you must enter this number manually The programmer applies a high voltage to the appropriate pins on the socket This is necessary to enable the system to read the device ID Do not insert into the socket a device that is not an EPROM or Flash It may be damaged when the programmer applies the high voltage We don t recommend apply this command to 2764 and 27128 EPROM types because most of them ID not supports Device Device options All settings of this menu are used for programming process serialization and associated file control Device Device options Operation options All settings of this command are used for programming process control This is a flexible environment which content items associated with current device and programmer type Items which are valid for the current device but aren t supported by current programmer are disabled These settings are saving to disk along with associated device by File Exit and save command The commonly used term are also explained in the user s manual to programmer The special terms used here are exactly the terms used by manufacturer of respective chip ___ _ _ A 51 AN Hie Please read the documentation to the chip you want to program for explanation of all used terms List of c
87. roves programming yield and guarantees long data retention 25 ki i Dataman 40Pro programmer is driven by an easy to use control program with pull down menu hot keys and on line help Selecting a device is performed by its class by manufacturer or simply by typing a fragment of vendor name and or part number Standard device related commands read blank check program verify erase are enhanced by test functions insertion test signature byte check and special functions autoincrement All known data formats are supported File formats are automatically detected and converted during load The rich featured autoincrement function enables to assign individual serial numbers to each programmed device or simply increments a serial number or the function enables to read serial numbers or any programmed device identification signatures from a file The software also provides information about the programmed device The drawings of all available packages are provided The software provides explanation of chip part numbers the meaning of prefixes and suffixes of the chips for each supported chip Various socket converters are available to handle device in PLCC SOIC SSOP TSOP TSSOP TQFP QFN MLF and other packages Advanced design including protection circuits original brand components and careful manufacturing allows us to provide a three year warranty on parts and labour for the Dataman 40Pro limited 25
88. s and PC failure interrupted cable Moreover a device is usually destroyed in the programming mode due to forced interruption of the control program Reset or switching the computer off due to removing the connecting cable or unplugging the programmed device from the ZIF socket An incorrectly placed device in the ZIF socket can also cause damage In system serial programming by Dataman 40Pro For general information recommendations and directions about ISP see section Common notes ISP please 28 Dataman 40Pro Description of Dataman 40Pro ISP connector 21 4 6 3 10 1 3m 58 78 gm Front view of the ISP connector Depending on the device you want to program the specification of ISP connector pins may change You can find it in the control SW for the programmer PG4UW menu Device Device Info Ctrl F1 Please be aware that the ISP programming option of a given device must be selected This is indicated by a ISP suffix after the name of selected device For additional ISP information please refer to the device manufacturer Note Pin no 1 is indicated by a triangle on ISP cable connector Dataman 40Pro ISP cable Warnings e When you use Dataman 40Pro as a ISP programmer do not insert a device in the ZIF socket e When you program devices in ZIF socket do not insert the ISP cable in the ISP connector e Use only included ISP cable When you use other ISP cables other material lengt
89. save or not to save options Other Page Other allows user to manage other program settings gt S gt __ S _ _ 79 pilt Panel Application priority allows user to set the priority of the program Priority settings can affect performance of programmer device programming time especially if there are running more demanding applications in the system Please note that setting application priority level to Low can significantly slow down the program In the panel Tool buttons hint display options on toolbar buttons in main program window can be modified In the panel Start up directory can be selected mode of selecting directory when program starts Default start up directory means directory from which program is called Directory in which program was lastly ended means the last current directory when program was lastly ended This directory assumes the first directory from directory history list Options View Use the View menu commands to display or hide different elements of program environment such as toolbars Following toolbars are available now Options View Main toolbar Choose this command to show or hide the Main toolbar Options View Additional toolbar Choose this command to show or hide the Additional toolbar Options View Device options before device operation Choose this command to enable disable display of Device options before device operation is confirmed Options Protecte
90. so that you can be sure that you are using latest and or optimal programming algorithms that were created for this new device Appendix B AlgOR service Algorithms On Request AlgOR is a free service by which we respond as flexible as possible on the customer s request to implement programming support for new devices This service may be used also for requesting new features of the control program AlgOR process is simple The user sends to Dataman a request for additional support for XXX device to the control program we may ask for up to date data sheets and samples if needed After completion the user will obtain a new version of the control program with requested features We will of course also return the borrowed samples If we cannot satisfy your requirements too expensive algorithms not available additionally module needed we will promptly contact to you and propose an appropriate solution _ EE SS Z 98 Appendix Note e Please use AlgOR Algorithms On Request form and send it direct to Dataman e AIgOR service is free of charge Therefore we do not accept any claims regarding this service Dataman Programmers Ltd reserves the right to set the dispatching priority on the particular tasks according to its own judgment Visit please the www dataman com site and use the AlgOR form Support section to ask the new chip support If you haven t access to Internet please make a copy of this page to A4
91. st information about the programmer hardware and software at www dataman com Using programmer software Launch PG4UW exe to enter the control program The menu Device contains the device manipulation commands The menu File contains commands for files and directories The menu Buffer is to be used for buffer manipulation Programming a device the shortest way Use the hot key lt Alt F5 gt to input the device name and or manufacturer to select the desired type of target device If you want to copy an existing device insert it into the ZIF socket of the programmer and then press key lt F7 gt If you want to program a target device with data from a disk press key lt F3 gt and read the appropriate file into the buffer Then insert your target device into the ZIF socket To check if the device is blank press key lt F6 gt Now you can program the device by pressing key lt F9 gt After programming you may perform additional verification by pressing key lt F8 gt 10 Detailed description Detailed description Dataman 48Pro Dataman 48Pro Introduction Dataman 48Pro is the first member of a new USB compatible generation of Windows 95 98 Me NT 2000 XP based universal programmers It is built to meet the demands of the development community for a fast reliable and versatile programmer Dataman 48Pro supports the silicon technologies of today and tomorrow for programmable devices without family specific m
92. switch on supply voltage Target supply settle time determines time after which must be supply voltage in target system stabilized at set value and target system is ready to any action with programmed device Voltage fall time determines skew rate of falling edge of target supply voltage switch off supply voltage Power down time determines time after switch off target system power supply within target system keeps residual supply voltage e g from charged capacitor After this time gt SSSSSSSSSSS SS _ _ _ S 53 gan GU gil Ji elapsed target system has to be without supply voltage and can be safely disconnected from programmer group Target System Parameters Oscillator frequency in Hz oscillator s frequency of device in target system Control program sets programming speed by its therefore is necessary set correct value Supply voltage in mV supply voltage in target system Control program checks or sets it depends on programmer type entered supply voltage in target system before every action on device Disable test supply voltage disables measure and checking supply voltage of programmed device set in Supply voltage edit box before action with device Delay after reset active this parameter determine delay after Reset signal active to start action with device This delay depends on values of used devices in reset circuit of device and can be chosen from these values 10ms 50ms 10
93. t batch of devices in multiple socket module programmer is completely programmed and verified without errors Note Serialization can work with control program s main buffer only It means the serialization can be used for device areas placed inside control program s main buffer Device special areas placed outside the program s main buffer could not use serialization feature Device Device options Serialization Incremental mode 55 pil The Incremental mode enables to assign individual serial numbers to each programmed device A starting number entered by user will be incremented by specified step for each device program operation and loaded in selected format to specified buffer address prior to programming of each device There are following options that user can modify for incremental mode S N size S N size option defines the number of bytes of serial value which will be written to buffer For Bin binary serialization modes values 1 4 are valid for S N size and for ASCII serialization modes values 1 8 are valid for S N size Address Address option specifies the buffer address where serial value has to be written Note that address range must be inside the device start and device end addresses Address must be correctly specified so the last highest or lowest byte of serial value must be inside device start and device end address range Start value Start value option specifies the initial value from
94. t to use the latest version of the control program e Semiconductor manufacturers continuously introduce new devices with new package types manufactured by new technologies in order to support the need for flexibility quality and speed in product design and manufacturing To keep pace and to keep you up to date we usually implement more than 500 new devices into the control program within a year Furthermore a typical programmable device undergoes several changes during its lifetime in an effort to maintain or to improve its technical characteristics and process yields These changes often impact with the programming algorithms which need to be upgraded the programming algorithm is a set of instructions that tells the programmer how to program data into a particular target device Using the newest algorithms in the programming process is the key to obtaining high quality results In many cases while the older algorithm will still program the device they may not provide the level of data retention that would be possible with an optimal algorithm Failure to not use the most current algorithm can decrease your programming yields more improper programmed target devices and may often increase programming times or even affect the long term reliability of the programmed device e Occasionally we make mistakes too Our commitment is to implement support for these new or modified parts before or as soon as possible after their release
95. th the selected programmable device Such as device select read data from device device blank check device program device verify and device erase 48 Software Device Select from default devices This window allows selecting one of the previously used devices This window is a cyclic buffer in which are stored the last 20 selected devices including its device options This list is saved to disk by command File Exit and save If you wish display additional informations about the current device use an lt Ctrl F1 gt key This command will display the device size organization programming algorithm and a list of programmers including auxiliary modules that support this device Package information and other general information about current device is also available Use the lt Del gt key for delete of current device from the list of default devices You can delete all but the last device used from the list Device Select device This window allows selecting a device from all the devices supported It is possible to sort by name by type or by manufacturer The selected device is automatically saved to a buffer of default devices max 20 devices This buffer is accessible with Device Select from default devices command If you wish to display additional information about the current device use an lt Ctrl F1 gt key This command displays the size of device organization programming algorithm and a list
96. the PC All programmers function flawlessly on systems running Windows 95 98 Me NT 2000 XP These programmers are driven by an easy to use control program with pull down menus hot keys and online help The Control program is the same for both of these programmers Dataman 48Pro and Dataman 40Pro Advanced design including protection circuits original brand components and careful manufacturing allows us to provide a three year warranty on parts and labour for the programmers limited 25 000 cycle warranty on ZIF socket This warranty is valid for customers who purchase a programmer directly from Dataman The warranty conditions of Dataman distributors may differ depending the law system or resellers warranty policy Free additional services e free technical support phone fax e mail e free lifetime software update via Web site e AlgOR Algorithm On Request service allows you to receive software support for programming devices not yet available in the current device list Free software updates are available from our Internet address www dataman com Products configuration Before installing and using your programmer please carefully check that your package includes all next mentioned parts programmer LPT cable USB cable power supply diagnostic POD ISP cable ZIF anti dust cover User s manual registration card shipping case Dataman 48Pro elelelelelelelelele Dataman 40Pr
97. the field Target device is the device microcontroller PLD etc which is to be in system programmed Target system is the physical Printed Circuit Board PCB which contains the device to be in system programmed ISP programmer is programmer which has in system programming capability for example Dataman 48Pro Dataman 40Pro General rules for in system programming We recommended respect following rules to avoid damage PC ISP programmer and target device or target system e Ensure common earth point for target system ISP programmer and PC e For laptop or other PC that is not connected to common earth point make hard wired connection from laptop to common earth point for example use LPT or COM port D connector e Any devices connected to target system must be connected to common earth point too User ternal PC ISP programmer Target perdi System 1 2 3 1 Earth connection to PC a Common earthing point 2 Target system earth 3 Earth from external device 87 BANA HILL Direction of connect Dataman ISP programmer to target system During in system programming you connect two electrical devices ISP programmer and target system Unqualified connection can damage these devices Note When you don t keep below directions and you damage programmer during in system programming it is damage of programmer by unqualified manipulation and is o
98. tifier Optional Recommended C DO_BLANK_CHECK DO_VERIFY C DO_SECURE C DO_LOW_TEMP_PROGRAMMING C DO_DISABLE_ISP_CLAMP C DO_READ_USERCODE Device te toJam Use J EPM7064AE Jam Player version 2 see Action and Procedures controls Action Select the desired action for executing 68 Sofiware Jam file of version 2 consists of actions Action consists of calling of procedures which are executed Jam file of version 1 does not know statements action and procedure therefore choice Action is not accessible Program flow starts to run instructions according to boolean variables with prefix DO_something If you need some new boolean variables with prefix DO_something then contact us Procedures Program flow executes statements from each procedure Procedures may be optional and recommended Recommended procedures are marked implicitly You can enable or disable procedures according to your needs Jam Player executes only marked procedures Other procedures are ignored Number of procedures is different it depends on Jam file Variables Jam file of version 1 does not know statements action and procedure Program flow starts to run instructions according to boolean variables with prefix DO_something Jam Player executes all marked DO_something cases in algorithm Number of variables procedures is constant it does not depend on Jam file If you need some new boolean variables with
99. tion see Products configuration PC requirements uf QUICK Star anasak Naga a aaa aa a Ta aaa a ang aaa aia anaa aaa Detailed description 440ss0esanesarennsa nen nnen nen nae nana nen naen nga nen nnenawan Dataman 48Pro Introduction 4 Dataman 48Pro element 0anaeaane aane n nean anan nana n nean 15 Connecting Dataman 48Pro to the PC saeaeeeaeenenenee nenen 16 Manipulation with the programmed device eee eee 17 In system serial programming by Dataman 48Pro 0 17 Selftest and calibration c cccccccceceeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 18 Technical specification ececcececeeeeseneeeeeeeeeeeeeeeteeeeeteneeeeseaaes 19 Datamann 4OPro isis asas earar a ane gan naga Wan ni ap oduan ga ea ani gang aaa 24 IntrODUCTION KA ANNA NA GAN a ence a iaaa iiaeia 25 Dataman 40Pro elements 0aaneaaee nane anana nana anana naen nen 27 Connecting Dataman 40Pro to PC aaeeeseneweneeanen anna enn eee 28 Manipulation with the programmed device asna0eaanenane 28 In system serial programming by Dataman 40Pro eee 28 Selftest and calibration c ceceeeeeseeeeteeeteeeeeees Technical specification Software siesta ee a a eae The programmer SOfWAMEC 0 ee cece cee eeeeceeeeeeteeeeeeeeeeeenaes 36 Ls perenne EAE ean aa akh aaa a
100. tronic 4 and 8 bit series e Microcontrollers Microchip PlCmicro PIC10xxx PIC12xxx PIC16xxx PIC17xxx PIC18xxx dsPIC series e Microcontrollers Motorola Freescale HCO8 GT LJ QY QT series e Microcontrollers Philips LPC series e Microcontrollers Tl MSP430 e PLD Lattice isoGAL22xV10x ispLSI1xxxEA ispLSl2xxxE ispLSl2xxxV ispLSl2xxxVE ispLSI2xxxVL M4 xx xx M4LV xx xx M4A3 xx xx M4A5 xx xx LC4xxxB C V ZC e Various PLD also by JAM player JTAG support e Altera MAX 3000A MAX 7000A MAX 7000B MAX 7000S MAX 9000 MAX II e Xilinx XC9500 XC9500XL XC9500XV CoolRunner XPLA3 CoolRunner Il Notes e Devices marked with are obsolete and require an additional module for programming e For all supported devices see actual Device list on our website www dataman com LC Tester e TTL type 54 74 S LS ALS H HC HCT series e CMOS type 4000 4500 series e static RAM 6116 624000 e user definable test pattern generation 21 l Mi gil Package support e package support includes DIP PLCC SOIC PSOP SSOP TSOP TSSOP TQFP QFN MLF SDIP BGA and others e support all devices in DIP with default socket e support devices in non DIP packages up to 48 pins with universal adapters e programmer is compatible with third party adapters for non DIP support Programming speed Device Operation Time B AT29C040A programming and verify 21sec AM29DL323DB programming a
101. uired just for older programmers without insertion test capability For others programmers is the value ignored Hardware Due a large variety of parallel port types a case may occur when the programmer cannot get concerted with the PC This problem may be shown as none communication between the PC and the programmer or by unreliable communication If this behaviour occur try to connect your programmer to some other PCs or other parallel ports near you If you find none solution please document the situation i e provide us an accurate description of your PC configuration including some other circumstances bearing on the problem in question and advise the manufacturer of your problem Don t _ _ SSSSS S sS S S _ _a 86 Common notes forget please enter of PC type manufacturer speed operation system resident programs your parallel port I O manufacturer and type Use please Device problem report form for this purpose see Appendix A ISP In System Programming Definition In system programming allows programming and reprogramming of device positioned inside the end system Using a simple interface the ISP programmer communicates serially with the device reprogramming nonvolatile memories on the chip In system programming eliminates the physical removal of chips from the system This will save time and money both during development in the lab and when updating the software or parameters in
102. use guru every office has one e Ask the person who already installed the programmer elf the problem persists please call the local dealer from whom you purchased the programmer or call Dataman direct Most problems can be solved by phone e mail or fax If you want to contact us by e Mail fax Copy the DEVICE PROBLEM REPORT form and fill it in following the instructions at the end of the form Write everything down that you consider being relevant about the programmer software and the target device Send the completed form by mail or fax to Dataman fax number in the control program menu Help About or to your local dealer If you send the form by fax please use black ink a good pen and large letters E mail Use DEVICE PROBLEM REPORT form from our internet site and fill it in following the instructions at the end of the form Use standard ASCII editor Write everything down that you consider being relevant about the programmer software and the target device Send the completed form by e mail to your local dealer or to Dataman support dataman com Phone Copy DEVICE PROBLEM REPORT form and fill it in following the instructions at the end of the form Write everything down that you consider being relevant about the programmer software and the target device Send the completed form by mail or fax to Dataman fax number in the control program menu Help About or to your local dealer If you send the form by fax pleas
103. ut of warranty 1 Turn off both devices ISP programmer and target device 2 Assign same GND potential for all devices e g connect GND of all devices by wire 3 Insert one connector of ISP cable to ISP programmer turn on programmer and control program 4 In control program select target device and operation options 5 Start action on target device read program 6 After direction of control program connect other ISP cable connector to target system and turn on it 7 After direction of control program disconnect other ISP cable connector from target system and turn off it 8 If you need another action on target device you continue with step 5 The recommendation for design of target system with ISP programmed device The target system must be designed to allow all signals which are use for In system programming to be directly connected to ISP programmer via ISP connector If target system use these signals for other function is necessary isolated these signals Target system mustn t affect these signals during In system programming For in system programmable devices manufacturers publish application notes Design of Dataman programmers together with respect of these application notes allow proper In system programming Condition is exactly respect these application notes Applications notes which Dataman use in ISP programmers are published in www dataman com section Application notes Please read some notes for following r
104. value Ctrl Shift F2 fill buffer with random data F3 copy block is used to copy specified block of data in current buffer on new address Target address needn t be out from source block addresses F4 move block is used to move specified block of data in current buffer on new address Target address needn t be out from source block addresses Source address block or part will be filled by topical blank character F5 swap bytes command swaps a high and low order of byte pairs in current buffer block This block must started on even address and must have an even number of bytes If these conditions do not fulfil the program modifies addresses itself start address is moved on lower even address and or end address is moved on higher odd address F6 print buffer F7 find string max length 16 ASCII characters F8 find and replace string max 16 ASCII chars F9 change current address F10 change mode view edit F11 switch the mode of buffer data view between 8 bit and 16 bit view It can be also do by mouse clicking on the button to the right of View Edit mode buffer indicator This button indicates actual data view mode 8 bit or 16 bit too F12 checksum dialog allows to count checksum of selected block of buffer change mode view edit Arrow keys move cursor up down right and left Home End jump on start end current line PgUp PgDn jump on previous next page Ctrl PgUp PgDn jump on start end current page Ct
105. want to search starting from the current cursor position In edit mode Forward from the current position or start of buffer to the end of the buffer is the default Backward searches toward the beginning Origin specifies where the search should start Find amp Replace dialog box Enter the search string in the Text to find input box and enter the replacement string in the Replace with input box The Options box allows you to select prompt on replace if program finds the string you will be asked before the program changes it Origin specifies where the search should start S gt S gt S gt S gt S gt S gt gt _ _ SES EE E E EE_ _ _ gt 45 Hilt Direction box specifies which way you want to search starting from the current cursor position In edit mode Forward from the current position or start of buffer to the end of the buffer is the default Backward searches toward the beginning In view mode searches all buffer Press lt Esc gt or click Cancel button to close dialog window By pressing Replace button the dialog box is closed and a Question window is displayed This window contains following choices Yes replaces found item and finds next No finds next item without replacing current one Replace All replaces all found items Abort search aborts this command View Edit buffer for PLD Ctrl F2 erase buffer with specified blank value Ctrl Shift F2 fill buffer with r
106. window only e New deletes old Log file and creates new one during each start of control program e Append adds Log window reports into existing Log file If file does not exist the new file will be created The Log file settings can be saved to disk by command Options Save options Display errors This option allows to set a form of error displaying as a result of programmed data verifying Errors can be displayed to the screen max 45 differences saved to error file of differences on the disk or it will not be displayed In case the displaying errors are turned off the control program reports a warning message in INFO window only The default error file name is Verify err The file name and directory can be user specified in edit box Error file name Following Display errors settings are available e None does not display error values on screen nor to the file e Screen default displays errors to Log window e File writes error reports to error file The Display errors settings can be saved to disk by command Options Save options Save options Page allows you to select the program options saving when exiting program Three options are available here e Don t save don t save options during quitting program and don t ask for saving options e Auto save save options during quitting program without asking for saving options e Prompt for save program asks user for saving options before quitting program User can select to
107. wing actual settings are saved to configuration file address size serial value incremental step and settings of modes ASCII BIN DEC HEX LS byte MS Byte first When from file mode is active following actual settings are saved to configuration file name of input serialization file and actual label which indicates the line with actual serial number in input file When program is in multiprogramming mode multiple socket programmer is actually selected the special section Action on not programmed serial values due to error is displayed in dialog Serialization In this section two choices are available 1 lgnore not programmed serial values 2 Add not programmed serial values to file Ignore not programmed serial values means the not programmed serial values are ignored and no action is done with them Add not programmed serial values to file means the not programmed serial values are added to file The file of not programmed serial values has the same text format as serialization file for From file serialization mode So there is possible to program the serial values later on by From file serialization mode If device programming is stopped by user program will not change the serial values ready for next batch of devices The same situation is if device program is incomplete e g for device insertion test error Ignoring or writing not programmed serial values is only used when at least one device from curren
108. yte s is set the buffer content will look as Byte buffer organization Address Data 0000080 CD xx xx AB xx xx 34 xx XX 12 XX XX XX XX XX XX Word16 buffer organization Address Data 0000040 xxCD ABxx xxxx XX34 12XX XXXX XXXX XXXX When Split serial number at every 4 byte s is set the buffer content will look as Byte buffer organization Address Data 0000080 CD xx xx xx AB xx xx xx 34 xx xx xx 12 Word16 buffer organization Address Data 0000040 xxCD KANA xxAB XXXX xx84 XXXX XX12 XXXX 60 Software Advice When you are not sure about effects of serialization options there is possible to test the real serial number which will be written to buffer The test can be made by following steps 1 select wished serialization options in dialog Serialization and confirm these by OK button 2 in dialog Device operation options set Insertion test and Device ID check if available to Disabled 3 check there is no device inserted to programmer s ZIF socket 4 run Device Program operation for some types of devices it is necessary to select programming options before programming will start 5 after completing programming operation mostly with some errors because device is not present look at the main buffer View Edit buffer at address where serial number should be placed Note Address for Serialization is always assigned to actual device organization and buffer organization that control program is using for current dev
109. zation is read from project file by following procedure 1 Serialization settings from project are accepted 2 Additional serialization file search is performed If the file is found it will be read and serialization settings from the additional file will be accepted Additional serialization file is always associated to the specific project file When additional serialization file settings are accepted project serialization settings are ignored Name of additional serialization file is derived from project file name by adding extension sn to project file s name Additional serialization file is always placed to the directory serialization into the control program s directory Example Project file name my_work prj Control program s directory c Program Files Programmer The additional serialization file will be c Program Files Programmer serialization my_work prj sn Additional serialization file is created and refreshed after successful device program operation The only requirement for creating additional serialization file is load project with serialization turned on Command File Save project deletes additional serialization file if the file exists associated with currently saved project File Save project This option is used for saving the project file which contains settings of device configuration and buffer data saved Data saved to project file can be restored anytime by menu command File Load project