MR-12 - User manual
Contents
1. TIME Rocker Shaker MR 12 Fig 1 Front panel Page 6 increment 1 Pressing the key for more than 3 sec will increase the increment The set parameters can also be changed during operation Program execution 4 6 Place samples on the platform arranging the load symmetrically relative to the tilt axis A Caution Do not place any objects between the platform and the shaker body 4 7 Press the RUN key Fig 1 6 The platform will start shaking and the timer indicator will start counting up the time interval with 1 min precision 4 8 If the platform is overloaded the device will make three attempts to restart the operation indication DRIVER ERROR If the attempts fail a flashing OVERLOAD reading will be shown on the display accompanied by the repetitive sound signal until the STOP key Fig 1 7 is pressed Eliminate the causes of overload before restarting operation see p 4 6 4 9 After the set time elapses the platform motion will stop and the flashing STOP reading will be shown on the display accompanied by the repetitive sound signal until the STOP key is pressed 4 10 If necessary the unit can be stopped at any time during operation before the set time has elapsed by pressing the STOP key In this case the platform motion will stop when the platform achieves horizontal position Pressing the RUN key again will start the program from the beginning timer will be restarted 4 11 After finishing
2. Biosan is committed to a continuous programme of improvement and reserves the right to alter design and specifications of the equipment without additional notice Page 8 6 Maintenance 6 1 If the unit requires maintenance disconnect the unit from electric circuit and contact Biosan or your local Biosan representative 6 2 All maintenance and repair operations must be performed only by qualified and specially trained personnel 6 3 Standard ethanol 75 or other cleaning agents recommended for cleaning of laboratory equipment can be used for cleaning and decontamination of the unit Page 9 7 Warranty and Claims Tai a2 7 3 7 4 The Manufacturer guarantees the compliance of the unit with the requirements of Specifications provided the Customer follows the operation storage and transportation instructions The warranted service life of the unit from the date of its delivery to the Customer is 24 months Contact to your local distributor to check availability of extended warranty If any manufacturing defects are discovered by the Customer an unsatisfactory equipment claim shall be compiled certified and sent to the local distributor address Please visit www biosan lv Technical support section to obtain the claim form The following information will be required in the event that warranty or post warranty service comes necessary Complete the table below and retain for your records Model MR 12
3. gt Disconnect the unit from electric circuit before moving Disconnect the external power supply unit from power socket to turn off the unit gt If liquid penetrates into the unit disconnect it from the external power supply unit and have it checked by a repair and maintenance technician Page 3 DURING OPERATION gt Do not impede the platform motion gt No objects or body parts can be placed between the plaform and shaker body at any time gt Do not operate the unit in environments with aggressive or explosive chemical mixtures gt Do not operate the unit if it is faulty or has been installed incorrectly gt Do not use outside laboratory rooms gt Do not place a load exceeding the maximum load value mentioned in the Specifications section of this Manual BIOLOGICAL SAFETY It is the user s responsibility to carry out appropriate decontamination if hazardous material is spilt on or penetrates into the equipment 2 General Information MR 12 Rocker Shaker provides adjustable soft intensive growth media or solutions mixing in vessels or single use plastic bags placed on the platform Adjusting speed and angle of the platform shaking user can optimize a mixing process according to a task settled The device can be used for washing gels after electrophoresis it is ideal for biomolecule hybridization on strips and for staining and washing of strips and slides When installed into
4. Shaker Rocker Serial number Date of sale Page 10 8 Declaration of Conformity Declaration of Conformity Equipment name Directive Manufacturer Type of equipment Applied pplied Standards Eiieised MR 12 Rocker Shaker EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC RoHS 2011 65 EC WEEE 2002 96 EC amp 2012 19 EU SIA BIOSAN Ratsupites 7 build 2 Riga LV 1067 Latvia Electrical equipment for measurement Control and laboratory use EMC requirements General requirements EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use General requirements EN 61010 2 051 Particular requirements for laboratory equipment for mixing and stirring Date this product conforms to the requirements of the above Directive s Signature Svetlana Bankovska Aleksandr Shevchik Managing director Engineer of R amp D 2 06 2014 42 06 2012 p Signature Date Version 2 01 October 2013 How to choose a proper Shaker Rocker Vortex ES 20 60 with heating Applications Microbiology Extraction Cell growing ES 20 with heating S a Volume of liquids 10 10 ml Erlenmeyer flasks Cultivation flasks and 50 ml tubes Multi Bio RS 24 aa Applications Multi RS 60 Microbiology Extraction Cell growing a cS w RTS 1 a V 1 App
5. a bioincubator the shaker is ideal for incubating cells and cell cultures in single use plastic bags with working volumes of up to 5 liters Rocker Shaker is equipped with a system of platform overload automatic detection In the case of overload an error message is shown on the unit s display accompanied by the sound signal This option ensures long term safe operation Page 4 3 Getting started 3 1 Unpacking Remove packing materials carefully and retain them for future shipment or storage of the unit Examine the unit carefully for any damage incurred during transit The warranty does not cover in transit damage 3 2 Complete set Package contents IMR 12RockerShaker sisssscccccdissasavvevsssceadeeanessiasacdsasaiaests 1 piece detachable platform sionen 1 piece Ubber Matprisene Eeyan a niaan eiie 1 piece fouUrscrews ANd AWIENCHN cccecccceeeeeeeeeseceeeseecaeeeeeeeees 1set external power supply Unit eee eeeeeeeeeeeeeeeeeeeeeeeeee 1 piece POWEF CONG e saa scneens aasnetedeseeniaaaeennts 1 piece Operating Manual Certificate 2 0 0 0 eeeeeeeeeeeereeeeees 1 copy 3 3 Setup place the unit upon firm stable even horizontal surface remove protective film from the display connect the power cord to the external power supply unit plug the external power supply unit into the 12 V socket at the rear side of the unit 3 4 Platform installation install the platform on the unit a
6. diovan Medical Biological Research amp Technologies MR 12 Rocker Shaker biosan Operating Manual for version Certificate V 2AW Contents Safety Precautions General Information Getting Started Operation Specifications Maintenance Warranty and Claims ON DOO FP WN Declaration of Conformity Page 2 1 Safety Precautions The following symbol means A Caution Make sure you have fully read and understood the present Manual before using the equipment Please pay special attention to sections marked by this symbol GENERAL SAFETY Use only as specified in the operating manual provided The unit should be saved from shocks and falling The unit must be stored and transported only in a horizontal position see marking on the package After transportation or storage keep the unit under room temperature for 2 3 hrs before connecting it to the electric circuit Use only cleaning and decontamination methods recommended by the manufacturer Do not make modifications in design of the unit ELECTRICAL SAFETY Connect only to a electric circuit with voltage corresponding to that on the serial number label gt Do not plug the unit into an ungrounded power socket and do not use an ungrounded extension lead gt Use only the external power supply unit provided with this product gt Ensure that the external power supply connector is easily accessible during use
7. lications DNA analysis pee Applications T Agglutination gg Camm Extraction MUE Gel staining m destaining Multi Bio 3D Applications Agglutination Extraction Blot hybridisation Gel staining destaining xa i 10 ml Petri dishes vacutainers and tubes up to 15 ml Medical Biological Research amp Technologies O PST 60HL PST 100HL with heating PST 60HL 4 with heating o e Applications ELISA analysis PSU 2T Hybridization Genome sequence ps 3500 a 4 nell TS 100 with heating TS 100C with heating and cooling Ore 10 10 ml PCR plates microtest plates and Eppendorf type tubes www biosan lv Biosan Sia Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 674 261 37 Fax 371 674 281 01 E mail marketing biosan lv
8. nd remove the rubber pad secure the platform on the supporting platform on top of the unit with the four supplied screws cover the platform with the rubber mat Page 5 4 Operation 4 1 Connect the external power supply plug to a grounded electric circuit 4 2 The display will turn on with the upper line showing time RPM and tilt angle set earlier Set fig 1 1 and the lower line Actual fig 1 2 showing current readings of the parameters 0 00 time mode indication STOP RUN Setting the parameters Use the readings in the upper line of the display while setting the necessary parameters 4 3 Setting time Time hr min Using the A and V TIME keys Fig 1 3 set the required working time interval in hours and minutes increment 1 min Pressing the key for more than 3 sec willincrease the increment Note If the operation time is not set and the timer indicator shows 0 00 pressing the RUN key Fig 1 6 will start continuous operation of the unit until the STOP key Fig 1 7 is pressed 4 4 Setting speed Speed RPM Using the A and W SPEED keys Fig 1 4 set the required shaking intensity in oscillations per minute increment 1 oscill min Pressing the key for more than 3 sec will increase the increment 4 5 Setting tilt angle Angle Deg Using the A and W ANGLE keys Fig 1 5 set the necessary angle 30 00 90 10 sA 0 00 STOP factual Time Speed Angle hr min RPM Deg SPEED ANGLE
9. the operation disconnect the external power supply unit from electric circuit Page 7 5 Specifications The unit is designed for operation in cold rooms incubators and closed laboratory rooms at ambient temperature from 4 C to 40 C and maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C 5 1 Mixing frequency Control range oe eeeeeeeeeeteeeeeeenees 1 99 oscill min 5 2 Mixing frequency setting resolution 0 eect eeeereeeeeeee 1 oscill min 5 3 Tilt angle range for 1 50 OSCIII MIN FANGS oe eee cece cette ee eee etteeeeeeetaeeeeeeeaes 0 10 for 51 99 OSCIII MIN FANGS oo eee eeeeeee eee eeteceeeeeeeeeeeeeeeeeaaaeees 10 5 4 Digital time setting cee 1 min 99 hrs 59 min non stop 5 5 Time Setting resolution i vcicsieisiceccceinttiece nen iame intent eens 1 min 5 6 Maximum continuous operation time ecceceeesereeeeeeeeeees 168 hrs 9 0 Maximum load eccessi a ein 5kg 5 8 Platform Working area sencecerneinonitrioi t niona 480x380 mm 5 9 DiMenSiONS nanana aa a aaa 430x480x210 mm 5 10 Input current power consumption 000 2 12 V 1 1A 13 W 5 11 External power supply input AC 100 240 V 50 60 Hz output DC 12 V S12 Ald l Le Caer erenre cr e E A N 11 9 kg Accurate within 10 Replacement parts Description Catalogue number PP 480 Detachable platform with non slip BS 010130 AK rubber mat