        ViaLite Alarm Concentrator User Manual (LAC-HB-5)
         Contents
1.                                                                   Position 8    The remote data stream is forwarded  together with local alarm information  in an RS232 electrical  format to external equipment e g  a PC or other system controller  in response to a poll command on the  serial data input via the D Sub connector at the rear of the 19    rack shelf  The remote module status 15  also made available in parallel form via the D Sub connector  This allows the system to be integrated  into    redundantly switched network     The Alarm Concentrator modules are bi directional  so that the status of remote modules can be  determined at either end of    cross site connection  This greatly aids the commissioning and fault  location during installation     Alarm Concentrator Alarm Concentrator  Transceiver LAC 1 Transceiver LAC                    5 2 5 4  20 Lo  23 23  ae 28  aE TE     2        2    2          GE  ne aL       Parallel output of  remote status    Parallel output of  remote status                                            A       Cross site Fibre  Optic Cable                            Serial RS232 Rx Lei   Serial RS232  data output     S Se  data output     Alarm inputs from  Alarm inputs from         local modules H       local modules                2 1 Module Operation  2 1 1 Installation    The Alarm Concentrator module is available in plug in module form for use in PPM   s ViaLite 19     Rack Case or in standalone configuration with    Converter Sleeve  
2.    If the module is being used in conjunction with the 19  Rack Case  the Alarm Concentrator must be  inserted into position 8  immediately to the left of the power supplies   This as shown in silkscreen on  the backplane and engraved onto the rear panel  The module is  hot pluggable  so can be inserted with  power supplied to the rack case without affecting signal modules already installed     Optical connections between local and remote modules are made at the rear of the module  Using two  clean FC APC cross site cables  link the input ports  I  of each module to the output ports  O  of the  mating module        2 2 Fibre Optic Cable  amp  Connectors    2 2 1 Care of fibre optic connectors    Modern optical connectors offer very high levels of performance  reliability and repeatability  However   they are more sensitive to damage and contamination than electrical connectors  In order to maintain  full performance from your fibre optic link system  it is necessary to take care to protect the connectors  from damage and to keep them clean     The light carrying core of a singlemode optical fibre is 8 um in diameter  and in a mating connector pair   the two cores must be aligned to better than lum in order to minimise insertion loss  The optical  connectors used in PPM   s systems maintain their performance even after hundreds of matings  as long  as they are kept clean  Dirt or contamination may result in the core being obscured or misaligned  and  this in turn results in hi
3.   Consult local PPM office     Alarm Conc  LED stays Remote module not powered  Power up remote module   RED   Optical connectors absent  dirty   Connect two clean undamaged  or damaged  optical fibres between modules     Optical loss between local and Consult optical budget section in  remote location too high  handbook     Status LEDs lights up RED    Remote module faulty or absent    Remedy module fault at remote  location appropriately        The ViaLite range of equipment is precision engineered and calibrated for optimum performance and  accuracy before dispatch     However  in the event of any problems or queries arising about the equipment  please contact PPM or  your local agent     18    6 Product Warranty    The Company guarantees its products  and will maintain them for    period of three years from the date  of shipment at no cost to the customer  Extended warranty options are available at the time of purchase     Please note that the customer is responsible for shipping costs to return the unit to PPM    The Company or its agents will maintain its products in full working order and make all necessary  adjustments and parts replacements during the Company   s normal working hours provided that the  Customer will pay at the rates currently charged by the Company for any replacements made necessary  by accident  misuse  neglect  wilful act or default or any cause other than normal use    Claims must be made promptly  and during the guarantee period    IMPORTANT    
4.   Please contact both your selling agent and PPM prior to returning any goods for Warranty or    Non Warranty repairs  Goods will not be accepted without    valid Goods Return Number   GRN      19    ViaLite ALARM CONCENTRATOR HANDBOOK  LAC HB  ISSUE 5 CR2874    O PULSE  POWER  amp  MEASUREMENT LTD 2011       PART OF THIS DOCUMENT MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM WITHOUT PRIOR WRITTEN PERMISSION   PPM LTD   65 SHRIVENHAM HUNDRED BUSINESS PARK  SWINDON  SN6 8TY  UK   TEL   44 1793 784389 FAX   44 1793 784391  EMAIL   INFO PPM CO UK WEBSITE   WWW PPM CO UK    
5.  for remote PSU failure  If either the Main or the Reserve remote  power supply modules fail  the local Alarm Concentrator will register    PSU alarm output     It is possible to determine which PSU has failed by observation of the status LEDs on the local Alarm  Concentrator  or by polling either Alarm Concentrator module using the RS232 feature     13       3 4 Serial Communication    The status of the Local and Remote modules as well as the Alarm Concentrator modules themselves can  be ascertained by polling either Alarm Concentrator module in    system pair  This can be done using  hyperterminal on a PC  or by using any proprietary RS232 controller     The connection to the RS232 port is made on rear panel 15way D Sub connector CONN8  immediately  behind the Alarm Concentrator Module   Pinout details are shown in section 3 3     The part number of the serial data lead required to interface with this port is 73635  This lead can be  obtained from your local PPM representative     3 4 1 Protocol    The protocol used for communication with the Alarm Concentrator is as follows      Parity   None   Number of Stop Bits   1  Number of Data Bits   8  Data Rate   9600 baud    3 42 Command Set    The Alarm Concentrator module can be polled for information using simple ASCII characters  The  table below lists valid commands        Command Function          Poll Status  This will return an ASCII serial data stream in the following format    LOC1 OK or FAIL  LOC2 OK or FAIL  LOC3 OK o
6.  the connectors from damage and to keep them clean     The cable connectors should always be cleaned before they are used  even if they have been protected  by dust caps     When the fibre optic cables are not connected  it is essential that the cable and module connectors are  protected by the dust caps provided with the system  Failure to do so may result in damage to the fibre    ends  which are critical to the system performance     Please refer to section 2 2 for fibre optic cable handling and cleaning instructions     2 Setting up and Understanding the Product    Please read fully document Lxx HB for information on installing your ViaLite equipment before  commissioning your RF link system     PPM s ViaLite Alarm Concentrator Transceiver module allows users to monitor the status of remotely  located fibre optic link modules    The status may be monitored   e visually via front panel LEDs       over a serial data output  and    e over a parallel data output     The Alarm Concentrator Transceiver module occupies position 8 in the ViaLite 19    rack shelf  It  concentrates all alarms from neighbouring modules within the same rack  and converts them into     serial data stream for transmission over optical fibre to an identical Alarm Concentrator Transceiver  module at the remote location  Here  the data stream is de multiplexed to provide    visual indication of  the status of remote modules via front panel LEDs                                                              
7. A  ViaLite        ViaLite  Alarm Concentrator    User Manual    LAC HB 5    CR2874 14 04 11 C                  Pulse Power  amp  Measurement Ltd  65 Shrivenham Hundred Business Park  Watchfield  Swindon  Wi      ay    UK  DENE Tel  44  0 1793 784389 Fax  44  0 1793 784391 Email sales ppm co uk www vialite                Instrument Care and Safety Information    Please read the whole of this section before using your ViaLite product   It contains important safety information and will enable you to get the  most out of your link     Electrical Safety       The ViaLite 19    Rack Case power supply units are Safety Class 1 products  having    metal case that is  directly connected to earth via the power supply cable      When operating the equipment note the following     e Hazardous voltages exist within the equipment  There are no user serviceable parts inside  and the  covers should only be removed by suitably qualified personnel    e The equipment does not have an isolating switch on the mains inlets  Equipment must be installed  within easy reach of a clearly labelled dual pole mains isolation switch    e Make sure that only fuses of the required rated current  and of the specified type  anti surge  quick  blow  etc   are used for replacement     Optical Safety       The ViaLite RF Alarm Concentrator modules contain optical sources operating at 1300nm nominal   These devices are rated at under IEC825 1    Safety of Laser Products     Part 1  First Edition  1993 as  CLASS 1 r
8. OR TECHNICAL DATA    15  AA    Seiser 15  4 2   Optical Budget Caleulations mme 15  4 3            Dimensions EE 16  4 4 A SE            17  5 MAINTENANCE AND FAULT FINDING GUIDE  ses 18  6 PRODUCT WARRANTY Luse 19    1 Introduction    1 1 ViaLite Alarm Concentrator    PPM s ViaLite Alarm Concentrator provides a high reliability  transparent cross site connection for the  transport of system alarm information for ViaLite communications equipment     Using optical fibre  information about alarm status from    remote location up to 20km away can be  relayed to the local module  whilst overcoming problems due to path loss and electro magnetic  interference etc     This enables PPM ViaLite equipment to be fully integrated into an Operations  Maintenance and  Control environment or    redundantly switched network                    ViaLite ViaLite ViaLite ViaLite ViaLite ViaLite ViaLite                                                                       T   Band L  Band L Band L Band L Band  950 2150MHz 950 2150MHz 950 2150MHz 950 2150MHz 950 2150MHz 950 2150MHz  Optical Tx Optical Tx Optical Tx Optical Rx                                                                                                                                                                   PPM s ViaLite Alarm Concentrator offers the following key advantages    e Visual indication of remote module status e g  laser fail  low optical carrier etc    e Parallel output of remote module status  for integratio
9. adiation emitting devices     When operating the equipment note the following     e Never look into the end of an optical fibre directly or by reflection either with the naked eye or  through an optical instrument    e Never leave equipment with radiating bare fibres accessible     always cap the connectors    e Do not remove equipment covers when operating    e Details of optical connections to the units  compatible fibre types and care instructions can be found  in the ViaLite system handbook  Please read this section before using the link     Adjustment  maintenance and repair of the equipment should only be carried out by suitably  qualified personnel     For more information on the ViaLite range of products  please refer to the ViaLite system  handbook Lxx HB     TABLE OF CONTENTS    1  INTRODUCTION sassanidene 5  1 1  ViaLite Alarm Concentrator meme 5  2                   ses neo      6  1 3     Care of fibre optic Connectors sem 7  2 SETTING UP AND UNDERSTANDING THE                          8  Zi             Operations E 9  2 2 Fibre Optic Cable  amp  Connectors mure 10  3 USING THE ALARM CONCENTRATOR MODULE ss 13  3 1   Connecting the Module mme 13  3 2 Front Panel Indicators  ereeeseserernsseseeesesesesnssereessesesesnsseseessesesesnsseseesseseseensesseessesssrensensesseesre 13  3 3   Parallel Alarm Outputs  essseseernsseesseersssesstesessssesseessssesseesenssseesseesnsssessesnsessesseesssssessesnsese 13  3 4     Serial Communication EE 14  4 VIALITE ALARM CONCENTRAT
10. e Power Supply Module 2       Power and Voltage Consumption        lt 4W at  12VDC   0 5VDC             Operating Conditions  Operating Temperature    0  C to  40  C       Storage Temperature    Optical Characteristics     40  C to  70  C             Output Power  20dBm nominal  Wavelength 1310   20nm  Fibre Singlemode 9 125  Corning SMF28 or equivalent       Optical Connector    FC APC Narrow key   gt 60dB return loss  Suhner FCPC Z M A601       Optical Path Length    Om to 20km for 1300nm  single mode fibre             Optical Power Budget       10dB  Typical fibre losses  Fibre  0 4dB km  Connectors  0 5dB max         4 2 Optical Budget Calculations    The maximum optical loss between local and remote modules to guarantee correct operation of the    Alarm Concentrator link is 8dB     The table below indicates typical losses for optical components that    are CLEAN AND IN GOOD CONDITION  The total loss of all the optical components in the system    should not exceed 8dB        Optical cable    0 4dB km       FC APC Connectors             0 5dB per bulkhead connection       15    4 3 Module Dimensions                                                                         Viatite  A  Modul       5  Alarm Concentrator en    E  TRANSCEIVER  LAC 1       Figure 1  Plug in Module    16                  EU          4       4 4 Alarm Connections    The circuit below shows how the alarm output should be configured for all types of ViaLite signal  module  The switch  to the left of t
11. gh insertion loss and poor link performance     The following precautions should be taken to maintain the performance of your link     e The cable connectors should always be cleaned before they are used  even if they have been  protected by dust caps     e When the fibre optic cables are not connected  it is essential that the cable and module connectors  are protected by the dust caps provided with the system     2 2 2 Connector and Cable Types    All ViaLite modules use singlemode  8um 125um  fibre terminated with FC APC optical connectors   Cross site cables are available in standard  3mm diameter  and heavy duty  8mm diameter  variants     FC APC is an industry standard for angle polished optical connectors and must not be confused    with standard FC PC connectors  The two connector types are not interchangeable and mating  one with the other will damage both the cross site interconnect and the module     2 2 3 Connecting and Disconnecting    The cable connectors should be cleaned before each and every connection  see 2 2 4      To connect FC APC optical connectors  align the centre ferrule on the cable connector with the female  receptacle in the module  There is a lug on the side of the ferrule  which must aligned to the gap in the  receptacle  When they are in alignment  push the plug gently home and finger tighten the knurled collet  onto the receptacle  See Figure 1 below     To disconnect FC APC connectors  unscrew the knurled collet on the plug and gently withdra
12. he dotted line  is internal to the module  The circuitry to the right of  the dotted line is provided by the system user      In the presence of an alarm condition  the module will act as    high impedance node and will NOT sink  current  This is    fail safe system in that an alarm condition will be raised when    module is not  present  This is an important factor when commissioning link management systems  as blank module  positions will register module faults     Internal to   External to  module   module    VEXT         Pull Up  Resistor       Alarm    Ground         This circuitry is also provided by the Redundancy Switch module and the Alarm Concentrator  module  When either of these modules are used  the alarm outputs can not be considered  VOLT  FREE   This is because the Redundancy Switch module and the Alarm Concentrator modules use  the same module alarm outputs to detect whether a unit has failed  When these modules are used  a  voltage of between 5V and 12V may be present on the  Alarm  output line when the module is in the  failed mode  When the module is working correctly  the voltage on the  Alarm  output line will be  OV   1 0  0   If true  VOLT FREE  contacts are required  please consult PPM     Maximum current   50mA  Maximum voltage   15V    17    5 Maintenance and Fault Finding Guide    Refer to the following table that gives    list of commonly encountered problems and suggested  solutions     Possible Causes    Power LED lights up RED    Internal fault
13. ion between the module and another remote Alarm Concentrator module     3 2 Front Panel Indicators    The transmitter has 11 front panel LEDS to indicate status                 Power LED Alarm Conc  LED Status LEDs  9   OFF Unit is Off Unit is Off Unit is Off or  No valid ACM link  GREEN   Unit is OK ACM Link OK Remote Module OK  RED Internal Fault No valid ACM link Remote Module Fault                      3 3 Parallel Alarm Outputs    With the Alarm Concentrator module fitted  all REMOTE module alarms are available on 15way D Sub  connector at module position 8 on the rear panel     This connector can be used to take alarm information to the local units for remote end switching using  the Vialite LRS n redundancy switch  See LRS HB for details     The open collector alarm outputs sink current in the absence of an alarm condition  When an alarm  occurs  the output goes into a high impedance state  Refer to section 4 4 for details of the alarm    interface     Backplane Alarm Concentrator Module 15way Connector          8    Pin Connections                                  Pin Function Pin Function   Number Number   1 Serial RS232 Data Output 9 Serial RS232 Data Input  2 Remote Module 1 Alarm 10 Remote Module 4 Alarm  3 Remote Module 2 Alarm 11 Remote Module 5 Alarm  4 Remote Module 3 Alarm 12 Remote Module 6 Alarm  5 Alarm Concentrator Alarm 13 Remote Module 7 Alarm  6  V 14 Remote PSU Alarm    7 Remote PSU Alarm  15 GND   8 GND                  There is only one alarm output
14. n into redundantly switched network  e Serial output of local and remote module status for interface to PC etc  via RS232    e Operation from 0m to  gt 20km    Complementary PPM ViaLite Products    e      Signal modules for RF GPS  L Band  70 140MHz  Broadband 2kHz 1500MHz and 10MHz   3GHz etc     e 19    Rack Case  e Redundancy Switch Module for fully automated 1 1 redundant operation     e Dual redundant power supplies for maximum availability    1 2 Part Numbers    This handbook covers the following modules        Part Number    Transceiver             Plug In Shielded  Module                            Refer to the ViaLite System Handbook for further details on the following ViaLite items        Part Number    Description                         LRKI1S Chassis for desktop or 19    rack installation  Accommodates up to 8 plug in modules and 2 mains  power supplies    LRK2S Chassis for 19    rack installation  Accommodates up to 8 plug in modules and 2 mains power  supplies    LPS M Main Power Supply plug in for LRK1S or LRK2S    LPS R Reserve Power Supply plug in for LRK1S or LRK2S    LRS 10 30 40 Redundancy Switch Module   F6R1 x FC APC Patchlead  2 8mm jacket  Length defined in metres by    x     Im  2m  5m  10m              1 3 Care of fibre optic connectors    Fibre optic connectors are more sensitive to damage and contamination than electrical connectors  In  order to maintain full performance from your fibre optic link system  it is necessary to take care to  protect
15. r FAIL  LOC4 OK or FAIL  LOC5 OK or FAIL  LOC6 OK or FAIL  LOC7 OK or FAIL   LOC PSU1 OK or FAIL  LOC PSU2 OK or FAIL  LAC OK or FAIL           OK or FAIL  REM2 OK or FAIL  REM3 OK or FAIL           OK or FAIL  REMS OK or FAIL  REM6 OK or FAIL  REM7 OK or FAIL  REM PSUI      or FAIL  REM PSU2 OK or FAIL             W Software Issue        14       4 ViaLite Alarm       4 1 Specifications    Parameter    oncentrator Technical Data    Value       Serial Data Input Output    9600 Baud RS232  8N1 via 15 way D type Female on 19    Rack Case or Converter  Sleeve       Parallel Data Input    Compatible with open collector alarm outputs via 19    Rack Case backplane PCB from  local modules       Parallel Data Status Outputs    Remote 1  Remote 2  Remote 3  Remote 4  Remote 5  Remote 6  Remote 7  Remote  PSU  Alarm Concentrator       Front Panel Indicator LEDs     Power        Alarm Concentrator local supply voltage  Remote Status LEDs       Alarm Concentrator        Confirms that data is being received from remote Alarm  Concentrator    Module 1        Alarm status of remote module I    Module 2        Alarm status of remote module 2    Module 3        Alarm status of remote module 3    Module 4        Alarm status of remote module 4    Module 5        Alarm status of remote module 5    Module 6        Alarm status of remote module 6      Module 7        Alarm status of remote module 7      PSU1        Alarm status of remote Power Supply Module 1     PSU2        Alarm status of remot
16. sidue from the receptacle     11    Important Notes              is flammable  Follow appropriate precautions and local guide lines when handling and storing  IPA              can be harmful if spilt on skin  Use appropriate protection when handling    e It should only be necessary to clean the female receptacles on the modules if problems are being  experienced    e Never inspect an optical fibre or connector with the naked eye or an instrument unless you  are convinced that there is no optical radiation being emitted by the fibre  Remove all power  sources to all modules  and completely disconnect the optical fibres     2 25 Minimum Bend Radius    Because the optical fibre is made of glass  it is important not to subject it to a tight bend radius  For this  reason  the fibre has a minimum bend radius  MBR  specification  beyond which the cable cannot be  bent without excessive loss or damage occurring     MBR specifications for PPM fibre are given in the ViaLite System Handbook Lxx HB     12    3 Using the Alarm Concentrator Module    3 1 Connecting the Module    Install as described in section 2 1  Immediately after power up  the module will perform    self test  during which the LEDs will illuminate in    set pattern  Assuming another Alarm Concentrator is  connected via the rear panel optical connectors  the module should be operational within 5 seconds  If  the  Alarm Conc   LED on the front panel is still illuminated red at this time  then there is not a valid  connect
17. w the  plug  Replace the dustcaps on both the receptacle and the cable connector     10    Figure 1       showing             connector with dust cap removed   b  showing alignment of the lug on the side of  the ferrule  which must match the gap in the receptacle shroud before gently pushing the plug home and  finger tighten the knurled collet nut onto the threaded receptacle         a   b     2 2 4 Care and Cleaning    The cable optical connectors should be cleaned before each and every use  even where they have been  protected with dust caps     It should only be necessary to clean the female receptacles on the modules if problems are being  experienced     Cleaning items required   e Lint free fibre cleaning tissues  normal cosmetic tissues produce dust and are not acceptable        Reagent grade Iso Propyl Alcohol    e      duster or FILTERED compressed air line    Cable Connector Cleaning   e Dampen a patch of cleaning tissue with IPA and clean all surfaces of the plug ferrule    e Using a dry cleaning tissue  dry the ferrule and polish the end face    e Using the air duster  blow away all residue from the end of the connector    Module Female Receptacle Cleaning  only recommended if problems are being experienced    e Twist a cleaning tissue to form a stiff probe  and moisten with IPA  Gently push the probe into the  receptacle and twist around several times to dislodge any dirt     e Repeat the above process with a dry tissue      Using the air duster  blow away all re
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Roller Dock - Presentes.pt  APPENDIX - Index of  Atlantis Land A02-WRA2-11B User's Manual  POWERMAX - Visonic  取扱説明書  EQUIPO PURIFICADOR DE AGUA NT-2W DE USO  GENEVA - Thuasne Deutschland GmbH  586ITOX Revision B+  Samsung E2230 Korisničko uputstvo  NBF...Q - ALLWEILER Service Portal    Copyright © All rights reserved. 