Home
Error Messages
Contents
1. Errors Displayed on the GP Error No Error Message Cause and Solution Reference RAAAO01 No project data No project file exists SF 27 2 Transfer exists Transfer a Transfer a project ring with a USB project Transfer Cable 27 2 2 Transfer Procedure W Transfer from PC to GP Send page 27 5 amp 97 3 Transfer ring Using Ethernet LAN 27 3 2 Transfer Procedure Transfer from PC to GP Send page 27 12 RAAA002 The project data size The project data size exceeds the maxi exceeds the capacity mum capacity Or the number of a 6 7 Seeing the screens exceeds 16 000 files Reference nest f oh tats Project Information the Project Information in GP Pro page 6 36 EX and make sure it does not exceed the general capacity RAAA003 The project data is There is an error in the project file 27 2 Transfer invalid Transfer the Transfer the project again ring with a USB project again Transfer Cable 27 2 2 Transfer Procedure W Transfer from PC to GP Send page 27 5 amp 97 3 Transfer ring Using Ethernet LAN 27 3 2 Transfer Procedure Transfer from PC to GP Send page 27 12 RAAA004 The system screen The system screen does not exist or is F 27 7 Transfer is invalid Execute invalid Tool Settings Guide forced transfer Force a transfer 27 7 1 Transfer Set tings Settings Guide page 27 37 RAAA005 The specified ini
2. CF memory loader BOOT CFG Abnormal Bo Lee Nie dalatnine CF card during startup Start up Error CF MOUNT Error CF card read failed during startup BOOT SYS LDMODULE SYS GP internal system data is deleted Start up Error Runtime Load NG STARTUP SYS ar damaged Start up Error Runtime Start NG Compulsion Transfer Mode DipSW2 ON Compulsion Transfer Mode Panel Touch Errors occurred during the GP sys tem s startup e Default font load error e User font load error Forced transfer display due to dipswitch 2 ON Compulsion transfer display forced by continuously touching the right or left bottom of the screen during startup 1 1 This item does not indicate an error GP Pro EX Reference Manual 30 25 Errors Displayed on the GP When an abnormal file is detected during the GP s startup When there is a problem with the files needed after the system starts up the following error messages will be displayed on the normal transfer screen After fixing the problem transfer the files again with the transfer tools e For details about the transfer tools please refer to 27 7 Transfer Tool Settings Guide page 27 35 Error Message Cause and Solution Reference An illegal or undetermined Device Address exists Please check the settings and transfer the project data again Appears when the device address used by a part or functi
3. exceeds the limit Make sure the total no of addresses set to parts on one screen does not exceed 1 000 S 6 414 Restric tions 6 14 1 Restric tions for Creating Screens No of Fea tures that can be Placed on a Screen page 6 132 The capacity of exceeds the limit Make sure the data capacity per screen does not exceed 1MB by separating the parts on different screens 6 14 Restric tions 6 14 1 Restric tions for Creating Screens No of Screens that can be Created page 6 131 GP Pro EX Reference Manual 30 12 Continued Errors Displayed while Error Checking Error Message Handling method Reference An error exists in The Data Display with input permit the Sampling Data Display and the Special Data Display displayed in CSV cannot be placed at the same time Make sure to place only one Display An error exists in Data Display with Popup Key pad is not available on a win dow screen Remove the Data Display s input permit feature or use the Bit action settings instead of the Touch action 7 14 12 Data Dis play Input Settings Guide 14 12 1 Numeric Display page 14 53 An error exists in Only 1 alarm summary fea ture can be placed ona screen Make sure to only place 1 Alarm part Summary on the screen For any oth ers the action may not function cor rectly SF 19 3 Viewing Active Al
4. Functions and make sure to input the correct format The Extended Script has an error Invalid Expression Refer to the comments displayed in the Message Area use the Tool Box and the Built in Functions and make sure to input the correct format SF 90 8 Settings Guide 20 8 1 Com mon Settings Guide D Script page 20 50 The no of Data Transfer Dis plays exceeds the limit of 32 The excess displays won t work Make sure the total number of displays placed in the whole project does not exceeds 32 An error exists in Up to 8 data block display graphs or historical trend graphs can be placed ona screen Up to 8 Data Block Display Graphs and Historical Trend Graphs can function on one Base Screen For 9 or more parts separate them on different screens amp 6 14 Restric tions 6 14 1 Restric tions for Creating Screens No of Fea tures that can be Placed on a Screen page 6 132 An error exists in Up to 40 channels of data block display graphs or histori cal trend graphs can be set Make sure the total no of channels for the Data Block Display Graph and His torical Trend Graph on one screen does not exceed 20 S 17 8 Restric tions 17 8 2 Restric tions for Historical Trend Graphs page 17 69 The no of parts of exceeds the limit Make sure the total no of parts placed on one screen does not exceed 384 The no of addresses of
5. Only 1 keypad can be called up on a screen Make sure to only place 1 keypad call screen with a registered keypad on the screen For any others the action may not function correctly SF 9 10 Pasting an Image page 9 62 A duplicate security setting password exists Please change the password Please set a different password for each level 99 5 Common Settings Guide Secu rity Settings 22 5 1 Password Settings page 22 9 GP Pro EX Reference Manual 30 14 30 3 Transmission Errors Transmission Errors Error Message Cause and Solution Reference Invalid IP Address The designated IP address value is illegal Input a correct IP address The IP Address already exists Add Change is disabled When adding an IP address the IP address is already set Designate an unused IP address Failed to receive the folder list Moved to the root folder The folder displayed in the CF card tool could not display so the display moved to the root folder The cause can be that the folder has been deleted or that the CF card has been changed Confirm whether the folder has been deleted or the CF card has been taken out The appointed file name already exists Please specify another name This appears when you are trying to rename a file in the CF card tool and the file name already exists Designate an unused file name SF 97 5 Transferring Only Data to
6. Script Check the commands format Program Com mands and Expres sions page 21 1 RAAA140 Extended D Script The total number of Extended Scripts SF 99 9 Restric Error The total no exceeds the limit The maximum num tions 20 9 2 of functions exceeds ber of Extended Scripts is 255 Extended Script the max of 255 Reduce the number of scripts by com Restrictions page bining two scripts into one etc 20 58 RAAA141 Extended D Script A function called in the Extended Script gt t Chapter 21 Error The specified does not exist Or there is an error in the Pradrani Coni function does not function Check the function s format mands and Expres exist or the function sions page 21 1 has an error RAAA142 Extended D Script Functions in the Extended Script are Error These func nested to 10 levels or more tions are nested to Reduce the levels in the if and loop 94 8 Descrip 10 levels or more structures tion Expression A nesting level is when function A 21 8 3 loop end calls function B and then again when _ 00p page 21 68 function B calls function C function calling level RAAA143 Extended D Script An incompatible function was found in Error An expres the project data s Extended Script sion exists that is Update the runtime s version not supported by this version RAAA144 Extended D Script SIO Operation functions are used
7. Settings Window Set ting Guide E Font Settings Settings Guide page 6 112 xxx Contains an illegal address Set a legal address Input an address for the specified loca tion address with a keypad SF 14 2 Displaying Inputting Numeric Data 14 2 2 Setup Procedure page 14 6 A symbol exists which has not been assigned real address Confirm this in the Symbol Settings Delete the parts using a symbol for the address settings or with no address set tings or set the address to parts with no address settings F 69 Symbolizing an Address 6 9 2 Setup Procedure page 6 45 The specified font has not been registered in Fonts for Projects Add it in Font Set tings or change the font S 6 13 Settings Guide 6 13 6 System Settings Window Set ting Guide E Font Settings Settings Guide page 6 112 Backup SRAM use exceeds the limit The excess part will not be executed Confirm this in the Project Information Make sure the total capacity of SRAM to use does not exceeds approximately 320KB approximately 120KB only for GP3202B SF 67 Seeing the Project Information page 6 36 The CF card feature is enabled As this model does not support CF card this fea ture will not work The GP3202B model supports the CF card export folder Change the model or do not set the CF card output folder SF 643 Settings Guide 6 13 6 System Settings Window Set
8. a CF Card page 27 27 Disconnected The CF card connection will be terminated The connection has been cut because of a removed cable etc Make sure that all cables are correctly connected LAN e Make sure that the PC s IP address is correctly set e Make sure that the type of cable is cor rect USB e Make sure that the USB cable is made by Digital Electronics Corporation e Make sure that the driver is installed Invalid password The password that you have entered is incorrect Enter the correct password Invalid password Transmission was canceled This appears when you enter the incor rect password 3 times Enter the correct password S 27 6 Permitting Transfer with Pass words page 27 30 Failed to open the socket The LAN port is not enabled Check the PC s LAN settings Failed to read the project Either the file is damaged or the file you have selected is not a project file Select the correct project file GP Pro EX Reference Manual 30 15 Continued Transmission Errors Error Message Cause and Solution Reference Failed to connect to the main unit Either a cable is loose or you are using an unsupported main unit Confirm the cable s type and connection and make sure the USB driver is installed E 27 2 Transferring with a USB Transfer Cable page 27 4 Failed to access the file You may not ha
9. a row delete the alarm in the last row and insert a row again GP Pro EX Reference Manual 30 2 Errors Displayed on the Editor 30 1 5 30 30 30 Image Management Error Message Cause and Solution Reference This setting may display the pasted image improperly because the selected color range is different from the one for the display unit or the drawing target The image may be displayed improp erly on the display unit due to the color range limit of the unit Check the color range and convert the image again SP ng 5 Changing Colors Line Types and Patterns page 9 33 Failed to read the image Specify another image Couldn t import because the file is damaged in use or the file has a dif ferent format Check the import from file and import it again Unable to convert the original file because it doesn t exist in Original File Location The convert from file doesn t exist in the specified location Specify the file location and convert the file again 1 6 Images Error Message Cause and Solution Reference Failed to read the image Please specify another image The specified image file is damaged or is not in BMP or JPEG format Specify the file again SF 9 10 Pasting an Image page 9 62 1 7 Print Error Message Cause and Solution Reference No print target exists because no setting has
10. been estab lished The print option is not selected Check the selected options and print again SF 98 6 Settings Guide 28 6 1 Print Settings Guide W Common Settings page 28 40 1 8 Screen Management Error Message Cause and Solution Reference Failed to read the specified project file Respecify the file to copy Confirm that the link to the file storage location is established and read the file again Failed to copy because the specified project was the cur rent one Specify another project To specify the current project file fin ish the editing and then specify the file SF 6 8 Copying a Screen from another Project page 6 40 GP Pro EX Reference Manual 30 3 Errors Displayed on the Editor 30 1 9 Address Block Conversion on Model Change Error Message Cause and Solution Reference Failed to import because the target file has a different for mat Couldn t import because the file is damaged or the file has a different for mat Check the import from file and import it again Failed to import because the addresses specified by the tar get file aren t the ones of cur rently set Devices PLCs Check the file address and import it again Failed to some of the data because the target file has a different format Confirm the individual device name and its address Check the file s individual device
11. name address and import it again Failed to import the target file Couldn t import because the file is damaged or in use Check the import from file and import it again Failed to export to the target file Verify that the file is not read only and check the specified save to drive and folder S74 Changing a Device PLC 7 4 2 Setup Procedure W Designat ing an Address Conver sion Range and Converting the PLC type page 7 23 30 1 10 Startup Error Message Cause and Solution Reference Unable to open two or more Open the same version of an Editor as different versions of a Editor at the running Editor a time No more Editor can be Up to two Editors can be opened at the opened same time 30 1 11 Built in Function Error Message Cause and Solution Reference The device set at the Start address must be the same as the one set at the End address Set the Start address and the End address to the same device The End address must not be the same as or lower than the Start address Please set the range correctly Set the End address to a greater address than the Start address GP Pro EX Reference Manual 30 4 Errors Displayed on the Editor 30 1 12 Sound Settings Error Message Cause and Solution Reference Unable to paste because the paste to range is incorrect Specify the paste
12. tions on Displaying Editing Printing CSV Data Display Restrictions page 25 116 An error exists in Only 1 Sampling Data Display can be placed on a screen Make sure to only place 1 Sampling Data Display on the screen For any others the action may not function correctly An error exists in Only 1 Historical Data Display Switch can be placed on a screen Make sure to only place 1 Switch Lamp Historical Data Display feature on the screen For any others the action may not function correctly An error exists in Only 1 Historical Trend Graph with the Historical Data Dis play feature selected can be placed on a screen Make sure to only place 1 Historical Trend Graph Historical Data Display feature on the screen For any others the action may not function correctly amp 17 8 2 Restric tions for Historical Trend Graphs W Restrictions for Dis play Historical Data page 17 71 An error exists in Up to 3 windows up to 2 in the case of global windows in which continuous read is set can be placed on a screen Make sure that the number of Window parts placed on the screen for continu ous read settings does not exceed 3 2 when using Global Windows Any other Windows will not function how ever up to 3 continuous read Windows and 381 common Windows can be placed on the screen 18 7 Window Part Settings Guide 18 7 1 Bit Action page 18 22
13. to range with N times N is 1 or larger integer the size of the copied range Beyond the address setting range Allotment exceeding ig not allowed Specify an address supported by the device PLC Failed to read the specified file Check the target file and read it again Failed to output the specified file after conversion Check the target file and output it again Failed to read the specified file because its format was unsup ported Convert the file into a supported for mat and read it again 96 5 Settings Guide 26 5 1 Com mon Settings Guide Sound Settings page 26 13 Cannot edit delete play the sound data because it does not exist Verify that there exists data inside the CF card Output Folder S67 Seeing the Project Information 6 7 2 Setup Procedure m CF Card Output Folder Setting Proce dure page 6 38 30 1 13 Peripheral Settings Error Message Cause and Solution Reference Cannot delete item because Device PLC has been used elsewhere in the Project File The cross reference tool will help you find where it has been used You cannot delete a device whose address is used for parts or features Change the address used for parts or features and delete the device F 65 Confirming the List of Addresses being Usedina Project File page 6 25 GP Pro EX Reference Manual 30 5 Errors Displayed on the
14. 30 Error Messages This chapter explains about Error Messages in GP Pro EX and their solutions They are divided into error messages displayed during screen creation during error checking during transfer and error messages displayed on the GP Turn to the page corresponding to each error 30 1 Errors Displayed on the Editor 0 eecceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeaeeeeeeseeaaes 30 2 30 2 Errors Displayed while Error Checking c cccceeeeeeeeeeeeeeeeeeeteneeeeneeees 30 11 30 3 Transmission Errors asea cieseagev ent dacd rs aacth acted teatee inhaler nin gatos 30 15 30 4 Errors Displayed on the GP 30 1 Errors Displayed on the Editor 30 1 30 30 30 30 1 1 D Script Errors Displayed on the Editor Error Message Cause and Solution Reference Unable to save the user defined function because of cross reference Modify the cross reference Cross reference means a condition in which a user defined function A calls a user defined function B and the user defined function B calls the user defined function A User defined functions cannot call each other Check the functions to call amp 90 6 Procedure for Creating Scripts 20 6 3 Setting Proce dure for Used Defined Functions page 20 42 1 2 Address Block Conversion Error Message Cause and Solution Reference An error occurred during Address Block Conversion Conversion is aborted
15. Editor 30 1 14 New Project File Error Message Cause and Solution Reference Failed to open because the file Confirm that the file extension is you are trying to open isn ta prx and open the file project file of this application Failed to open the project file Couldn t read because the target file is because of a file read error damaged or it has a different format B Check the read from file extension and read it again Aik Aa to startup GP PRO Verify whether or not PRO Pro PB3 is If the application has already installed been installed specify a file To install PRO Pro PB3 you will need and run it a separate CD 30 1 15 Symbol Variable List Error Message Cause and Solution Reference 30 30 Unable to delete the target symbol because it is currently in use You can check its loca tion using cross reference Change the symbol registered in parts to another symbol or address and then delete the target symbol F 69 Symbolizing an Address page 6 44 1 16 Security Settings Error Message Cause and Solution Reference The same password is in use Change your password You cannot specify the same password on multiple levels Change the pass word 99 5 Common Settings Guide Secu rity Settings page 22 9 The setting of Use level 15 password to go offline is enabled Set the level 15 password Please set
16. Output Folder and the specified drive and folder 67 Seeing the Project Information 6 7 2 Setup Procedure m CF Card Output Folder Setting Proce dure page 6 38 30 1 25 Mark Error Message Cause and Solution Reference Failed to update the mark Failed to delete the mark Verify that library the specified file is not read only and check the specified file and folder Failed to create a mark library Change the mark library name and cre because the specified mark ate a mark library again E library name is invalid Failed to rename the mark Change the mark library name and library because the specified rename the mark library again mark library name is invalid 30 1 26 Text Table Error Message Cause and Solution Reference A part beyond the given range of the no of characters rows exists Failed to paste Make sure that the no of characters and the no of rows in the text to be pasted are within the range S157 Settings Guide 15 7 3 Text Table Settings Guide page 15 49 Could not delete some cells that contains a massage Delete the message and then delete the cell GP Pro EX Reference Manual 30 8 Continued Errors Displayed on the Editor Error Message Cause and Solution Reference Failed to import because the target file has a different for mat Couldn t import because the file is damaged or the file has a differe
17. accessed and cannot be written to the GP due to damage etc After checking the access privileges for the PC s hard drive force the data to be sent amp 27 7 Transfer Tool Settings Guide 27 7 1 Transfer Set tings Settings Guide page 27 37 GP Pro EX Reference Manual 30 16 Continued Transmission Errors Error Message Cause and Solution Reference Failed to receive the project Please execute it again A data error occurred when receiving data Confirm that there is not a lot of noise occurring Do not use a USB exten sion cable etc Not send project The project data does not exist on the GP unit The unit is showing the default Initial Start Mode screen etc Or the data is damaged First transfer the project a es Settings Menu page 27 2 Failed to save the CF card data Either the CF card is not correctly inserted or it is write protected Make sure the CF card can be used you may not be able to access CF cards not made by Digital Electronics Corpora tion The project does not agree with the transfer destination main unit The transfer source project and the project inside the main unit are different and therefore could not be compared Only the same project can be compared E 27 4 Confirming Projects Changes Prior to Transfer Comparison page 27 24 The format went wrong The initialization of the main unit device
18. ailed to write to the CF card The CF card may not be correctly inserted or it may be write protected Make sure that the files in the CF card are not write protected The file required for transfer ring was not found A file needed for transfer is damaged or does not exist on the hard drive Reinstall the transfer tool amp 97 7 Transfer Tool Settings Guide 27 7 4 Transferring when Only Transfer Tool is Installed page 27 41 The timeout error occurred Confirm that there is not a lot of noise occurring Do not use a USB extension cable etc Exception error A module needed for transferring may not be correctly installed Reinstall the transfer tool amp 27 7 Transfer Tool Settings Guide 27 7 4 Transferring when Only Transfer Tool is Installed page 27 41 Failed to send the project The size of the project exceeds the max capacity The data size of the project file you are trying to transfer exceeds the GP s screen capacity Decrease the data size by deleting unnecessary screen data etc S67 Seeing the Project Information page 6 36 This project is the one created with the Trial version of the drawing software Please save it with the Product version before executing transmission Please save the data with the regular version Product version GP Pro EX Reference Manual 30 18 Errors Displayed on the GP 30 4 E Application Errors
19. and the Redo the Convert Addresses utility settings Follow the procedure and do the settings again F 6 6 Converting the Addresses in a Project File in Block original state is restored page 6 33 1 3 Address Control Error Message Cause and Solution Reference The inputted address is valid for two or more Devices PLCs Input the device name as well E 72 Connecting to Multiple Devices PLCs page 7 3 1 4 Alarm Text Error Message Cause and Solution Reference Beyond the address setting range Allotment exceeding x ig not allowed Verify the address settings range and run the automatic layout is the greatest possible address setting The permitted range from the current location is 1 Spec ify a value within the range Verify the address settings range and run the automatic layout is the greatest possible additional number of bits setting SF 199 Settings Guide 19 9 1 Alarm Settings Guide W Alarm Settings Guide Block 1 page 19 74 The relationship of the upper limit value to the lower limit value is incorrect Set an upper value limit that is greater than the lower value limit S499 Settings Guide 19 9 1 Alarm Settings Guide Word Monitoring page 19 76 Cannot insert a row due to an alarm set in the last row Row insertion is canceled Cannot insert an additional alarm row To insert
20. arms in a List 19 3 2 Setup Proce dure page 19 14 An error exists in Only 1 alarm part that uses the sub display can be placed ona screen When multiple Alarm parts History are placed on the screen sub displays will not function Ensure there is only one Alarm part History SF 199 Settings Guide 19 9 3 Text Alarm Settings Guide page 19 118 An error exists in Only 1 text alarm can be placed on a screen Make sure to only place text alarm on the screen For any others the action may not function correctly S 19 10 Restric tions 19 10 4 Text Alarm Restrictions page 19 137 An error exists in Only 1 CF file display feature of the Picture Display can be used in a screen Make sure to only place 1 Picture Dis play CF file display feature on the screen For any others the action may not function correctly SS 10 6 Restric tions 10 6 4 Restric tions for Picture Display CF Image Display page 10 56 An error exists in Up to 512 display positions whose no is set in Move Dis play can be placed ona screen Make sure that the no of displayed Image Display parts placed on one screen does not exceed 512 An error exists in Up to 30 move indications marks of Picture Display can be placed in a screen Please lessen the no of Image Display parts placed on the screen S 10 6 Restric tions 10 6 3 Restric tions for P
21. ct data s D Script Update the Z that is not supported runtime s version by this version GP Pro EX Reference Manual 30 21 Continued Errors Displayed on the GP Error No Error Message Cause and Solution Reference RAAA123 D Script Error The SIO Operation functions are used in a 7 6 13 Settings SIO operation func D Script while the device PLC settings Guide 6 13 6 System tion is used in a con are not set Configure the device PLC Sa aon waare nO settings ISeript Se Set Device PLC has tings Guide page 6 been set 118 RAAA124 The D Script has an There is an error in the used D Script Chapter 21 error Check the commands format die eae Wits sions page 21 1 RAAA130 Global D Script The total number of Global D Scripts Error The Total No exceeds the limit The maximum num of Global D Scripts ber of Global D Scripts available is 32 exceeds the maxi each function also counts as one 90 9 Restric mum of 32 script tions 20 9 1 D Script Global D Script RAAA131 Global D Script The total of all devices in the Global D Restrictions page Error The total no Script exceeds the limit of 255 devices 20 55 of devices exceeds Reduce the number of used devices by the maximum of using the Memory Operation function 255 etc RAAA132 Global D Script Error The function called in the Global D E chapter 21 The
22. failed Transfer again in a location where there is not a lot of noise occurring The transfer destination main unit was not found The designated communication device does not exist or cannot be used Confirm the PC s LAN settings and check if the USB driver is installed Failed transfer An error occurred during communica tion Confirm that there is not a lot of noise occurring Do not use a USB extension cable etc File access went wrong with the Machine The data write to the main unit failed due to a flash malfunction If there is no improvement even after a forced transfer contact customer sup port amp 97 7 Transfer Tool Settings Guide 27 7 1 Transfer Set tings Settings Guide page 27 37 Whether CF card is not inserted or non supported model Confirm whether the CF card is cor rectly inserted You may not be able to access CF cards not made by Digital Electronics Corporation GP Pro EX Reference Manual 30 17 Continued Transmission Errors Error Message Cause and Solution Reference The appointed file name already exists Please specify another name There is a directory with the same name as the file you are trying to copy Delete the content of the CF card and retransmit the file If an error occurs while you are transmitting the project force the transfer S97 5 Transferring Only Data to a CF Card page 27 27 F
23. icture Display Move Dis play page 10 54 An error exists in Only 1 data transfer feature of the Special Data Display can be used on a screen Make sure to only place 1 Special Data Display data transfer feature on the screen For any others the action may not function correctly GP Pro EX Reference Manual 30 13 Continued Errors Displayed while Error Checking Error Message Handling method Reference An error exists in Only 1 CSV display feature of the Special Data Display can be used on a screen Make sure to only place 1 Special Data Display CSV display feature on the screen For any others the action may not function correctly An error exists in Only 1 File Manager Display Special Data Display can be placed on a screen Make sure to only place 1 Special Data Display File Manager feature on the screen For any others the action may not function correctly An error exists in The edit mode of the CSV dis play feature of the Special Data Display cannot be placed on a window screen Make sure to use the CSV display fea ture of a Special Data Display placed on a base screen An error exists in The File Manager Display fea ture of the Special Data Dis play isn t available on the window screen Make sure to use the File Manager fea ture of a Special Data Display placed on a base screen SF 95 13 2 Restric
24. in a z 6 13 Settings Error The SIO oper Extended Script while the device PLC Guide 6 13 6 System ation function is used settings are not set Configure the a eae in a condition where qeyice PLC settings no Device PLC has Script Settings Set tings Guide page 6 been set 118 RAAA145 The Extended D There is an error in the used Extended Chapter 21 Script has an error Script Check the commands format Program Com mands and Expres sions page 21 1 RAAA150 The provided pass The security feature s password input is amp 7 22 4 Password word is incorrect incorrect Confirm that the input is cor Input Window 22 4 1 Please enter the cor rect upper case lower case letters etc Introducing the rect one and enter the password again Password Input Window page 22 7 GP Pro EX Reference Manual 30 23 Continued Errors Displayed on the GP Error No Error Message Cause and Solution Reference RAAA151 Change the screen This appears when a screen change from the host occurs from the PLC host by the forced screen change method the traditional method for a screen change and you cancel the displayed password input If you want to cancel make sure to use a cancel notification bit and return to the previous screen from the PLC host RAAA152 Cannot use the COM This appears when the COM port you amp 7 4 Cha
25. ing a Created Picture in a Package page 9 53 30 1 21 Duplicate Error Message Cause and Solution Reference Failed to create the specified no of duplicates because the set address range was exceeded The limit is up to OK KK Delete unnecessary parts if any and duplicate the parts again 6 14 Restric tions 6 14 1 Restric tions for Creating Screens No of Screens that can be Created page 6 131 Failed to make the specified no of duplicates because of exceeding the set address range For parts that have multiple addresses this message displays even if only one address exceeds the range Specify the address range and dupli cate the parts again 30 1 22 Part List Error Message Cause and Solution Reference Failed to export to the target file Check the export destination file or disk and export to it again GP Pro EX Reference Manual 30 7 Errors Displayed on the Editor 30 1 23 Parts Selection Toolbar Error Message Cause and Solution Reference Failed to read the target file The specified image file is damaged or is not in BMP or JPEG format Check the file to read and the drive Failed to write to the target file The file failed to write Check the file o to write and the drive 30 1 24 Project Properties Error Message Cause and Solution Reference Failed to create a folder Check the CF card
26. nfirm the import from file s data range The file is imported with the data out of range deleted SF 95 3 Creating Recipes CSV Data page 25 9 Failed to read because the tar get file has a different format Couldn t read because the target file is damaged or it has a different format Check the read from file and read it again Failed to read the target file Couldn t read because the target file is damaged or in use Check the file and read it again Failed to write to the target file Check the export destination file or disk and write to it again SF 95 3 Creating Recipes CSV Data page 25 9 GP Pro EX Reference Manual 30 10 30 2 Errors Displayed while Error Checking Errors Displayed while Error Checking Error Message Handling method Reference The port setting has overlap ping Please confirm that in the Peripheral List Confirm the peripheral device with the mark in the Port item and change to a port with no overlaps SF 79 Connecting to Multiple Devices PLCs 7 2 2 Setup Procedure page 7 4 The send data size exceeds the limit Confirm the send data size Set the User Screen Area within the fol lowing memory ranges for each model GP330x 6MB GP34xx to 37xx 8MB There is a chance that 90 or more of the memory will cause an error output because of the data structure SF 613 Settings Guide 6 13 6 System
27. nging a port are trying to use is already in use by oe Device PLC page 7 another feature Check the settings 18 again RAAA153 No dictionary file The English dictionary file does not was found exist in internal storage or in the CF card Transfer the project data again RAAA154 The specified filing This appears if the designated filing as data cannot be used data does not match the project data R oE with this project when transferring filing data from the Sees d oe Fy CF card to SRAM Make sure to use CSV page 24 20 filing data that matches the project data RAAA155 The IP address A machine with the same IP address duplicates that of exists on the network Change the IP 27 3 Transfer another device address of this machine or of the other ina Using Ethernet Please change the machine gee l LAN 27 3 2 Transfer address of either this Procedural Transfer machine or the other from PC to GP IP XXX XXX XXX X Send page 27 12 XX MAC XX XX XX XX XX XX RAAA156 The 9th pin of the The COM port s 9 pin could not be set to 6 13 Settings COM port has not VCC 5V power supply Check the Guide 6 13 6 System been set to VCC SV COM port s connection cable and the Settings Window Power Supply machine it is connected to Then reset ee f Please check your the machine or verify the project s script cript Se tings le CANE ar connetied settings are set to a SV powe
28. ngs English Standard Guide 6 13 6 System Japanese Standard Settings Window Korean Standard Setting Guide m Font Chinese Standard Settings Settings Taiwanese Standard Guide page 6 112 English Stroke Japanese Stroke Korean Stroke Chinese Stroke Taiwanese Stroke RAAA010 The CF card has not When trying to display a CF card file been inserted or the with a Picture Display the CF card has CF card hatch is not been inserted Copy the image file User Manual open or JPEG file to the CF card and insert the CF card into the GP3000 Series RAAA011 Failed to start from Regardless of whether DIP SW1 is ON the CF card the necessary file does not exist to start from the CF card Or the necessary file may have an error Copy the startup project to the CF card again RAAA050 Clock Setting Error When changing the clock data the data write to the clock IC failed The IC chip may be broken Continued GP Pro EX Reference Manual 30 20 Errors Displayed on the GP Error No Error Message Cause and Solution Reference RAAA051 Low battery Due to the low voltage of the backup lithium battery the backup SRAM s data is erased and the clock data will gt User Manual not be correctly kept Supply enough power to the GP and set the clock data again RAAA100 The system start The system device start address is not 7 6 13 Settings device address is set correctly or has an err
29. nt for mat Check the import from file and import it again Characters beyond the allow able no were not imported Language No Language Table Name Language No Language Table Name The specified file has data out of the specification range The file is imported with the data out of range deleted Language No 1 16 Language Outputted form in export Table Name No of Characters x No of Rows lt 1200 Failed to import the target file Couldn t import because the file is damaged or in use Check the import from file and import it again SF 156 Importing Exporting Registered Text Tables for Use with Different Projects page 15 30 Failed to import because of an unavailable language in the setting The language specified in the file s Language Settings is not specified for the currently opened project Check the import from file or add the font to use in the Font Settings section of System Settings and import the file again SF 4 2 Stroke Font Standard Font page 4 3 Failed to export to the target file Check the export destination file or disk and export to it again amp 15 6 Importing Exporting Registered Text Tables for Use with Different Projects 15 6 2 Setup Proce dure Export page 15 31 A part beyond the given range of the no of characters rows exists Failed to import Make sure that the no of characters and the no of ro
30. on s settings is invalid The part or function name using the invalid address is displayed in the brackets However sometimes the brackets are not displayed Cannot read the file required for startup Please transfer the project data again A file needed for startup could not be read Transfer again and restore the system The file name displayed inside the brackets is either abnormal or does not exist The no of Devices PLCs exceeds the limit Please check the settings and transfer the project data again The no of devices PLCs exceeds the maximum setting Large scale units 4 medium scale units 2 Reconfirm the project settings and transfer it again SF 613 Settings Guide 6 13 6 Sys tem Settings Win dow Setting Guide E Peripheral List Settings Guide page 6 113 GP Pro EX Reference Manual 30 26
31. or Guide 6 13 6 System incorrect Set the correct address while offline or S Gas A transfer a project tem Area Settings page 6 110 RAAA101 Illegal Undefined A device address in the part or function Device Address settings is illegal Make sure to set the correct device address RAAA102 Failed to read from Failed to read from the device PLC the Device PLC Confirm the connection status such as XXXX whether the communication cable is S User Manual disconnected etc The part name is entered in the paren theses RAAA103 The specified The designated address is incorrect address is incorrect Make sure to set the correct address XXXX RAAA120 D Script Error The The function called in the D Script does S specified function not exist Or there is an error in the Program ae does not exist or the function Check the function s format mands and Expres function has an sions page 21 1 error RAAA121 D Script Error Functions in the D Script are nested to These functions are 10 levels or more nested to 10 levels Reduce the levels in the if and loop amp 94 g Descrip or more structures tion Expression A nesting level is when function A 21 8 3 loop end calls function B and then again when 00p page 21 68 function B calls function C function calling level RAAA122 D Script Error An An incompatible function was found in expression exists the proje
32. r suppl PO RURE pag equipment 8 p PPply 118 RAAA157 Cannot put the The connected device main PLC allot Device PLC into ted to the System Top Device Address gt l offscan state when has been set to off scan The main PLC Au ae ee the system start cannot off scan If you want to off scan ea device TF IS the main PLC remove the setting that 6 110 ASSIJISENO tt uses the System Data Area Otherwise cancel the main PLC s off scan setting 1 IP addresses are shown as decimal MAC addresses are shown as hexadecimal GP Pro EX Reference Manual 30 24 Errors Displayed on the GP E System Errors When the GP s internal system will not start correctly When there is a problem with the files related to starting the system the following error mes sages will be displayed on the forced transfer screen Transfer the system data again with the transfer tools e For details about the transfer tools please refer to 27 7 Transfer Tool Settings Guide page 27 35 Error Message Affected Files Cause Boot cfg file needed for startup is RUN SYS Start up Error Boot cfg BOOT CFG deleted or damaged Start up Error Default Font seme FNT Default font data is deleted or dam aged Start up Error LanSys cfg LANSYS CFG LAN settings file is damaged Start up Error System cfg SYSTEM CFG Pileh needed j a the GP Syan system settings files do not exist Start up Error
33. specified func Script does not exist Or there is an Program par tion does not exist Or error in the function Check the func mands and Expres the function hasan tion s format sions page 21 1 error RAAA133 Global D Script Error Functions in the Global D Script are These functions are nested to 10 levels or more nested to 10 levels Reduce the levels in the if and loop 4 8 Descrip or more structures tion Expression A nesting level is when function A 21 8 3 loop end calls function B and then again when _ 00p page 21 68 function B calls function C function calling level RAAA134 Global D Script Error An incompatible function was found in An expression the project data s Global D Script exists that is not Update the runtime s version S supported by this version RAAA135 Global D Script Error SIO Operation functions are used in a SF 6 13 Settings The SIO operation Global D Script while the device PLC_ Guide 6 13 6 System oe is ra ina settings are not set Configure the te a condition where NO device PLC settings Script Settings Set Device PLC has keia de on 5 been set 118 GP Pro EX Reference Manual 30 22 Continued Errors Displayed on the GP Error No Error Message Cause and Solution Reference RAAA136 The Global D script There is an error in the used Global D Chapter 21 has an error
34. the level 15 password 99 5 Common Settings Guide Secu rity Settings W Extended Settings page 22 10 1 17 Multiple Languages Change Error Message Cause and Solution Reference Characters may not be nor mally displayed because the font for the specified language hasn t been installed on Win dows The selected table message includes a language font that cannot be displayed on the current OS Change the OS or add the font GP Pro EX Reference Manual 30 6 Errors Displayed on the Editor 30 1 18 Data Limitation Error Message Cause and Solution Reference Beyond the data limitation Check for errors Even if you save this data unit you can t transfer it to the main You can save the data with the error but you cannot transfer it to the main unit Check the error contents amp 30 1 Errors Dis played on the Editor 30 1 27 Recipe Set tings page 30 10 30 1 19 Template Error Message Cause and Solution Reference Failed to read the target tem Select a different template oT plate 30 1 20 Package Window Error Message Cause and Solution Reference It can be registered only ina user created package An user created part cannot be registered in the package Create a new package and register the created part in it 9 8 Editing the Same Picture on Another Screen 9 8 2 Register
35. tial The screen cannot display because the screen no does not screen number designated in the Initial T 6 13 Settings exist XXXX Screen Settings does not exist in the Guide 6 13 6 System project Change the Initial Screen No a or add the screen The screen number play Settings page designated in the parentheses is dis 6 90 played GP Pro EX Reference Manual 30 19 Continued Errors Displayed on the GP Error No Error Message Cause and Solution Reference RAAAOO6 The project data There are functions that cannot be rec contains functions ognized by the runtime program that are not sup The editor s version and runtime s ver ported by this ver sion may not match Update the runt SIgn ime s version RAAA007 The no of partsin There are more than 384 parts set ona 6 14 Restric the screen exceeds single screen tions 6 14 1 Restric the limit MAX 384 The number of parts exceeds the limit Ms for Creating during a screen change or when open ohana cen 8 8 P Screens that can be ing a window Make sure to set parts Created page 6 within the permitted range 131 RAAAO08 The font XXXX The font you are trying to display does does not exist not exist in the system Download the Transfer the font font into the system with the project The following table shows the font Meee S 6 413 Setti
36. ting Guide Device Settings Settings Guide page 6 89 FG 7 Seeing the Project Information page 6 36 An error exists in D Script ID No has an invalid expression Use the support input functions such as the Tool Box Built in Functions etc and ensure that the format is inputted correctly and that no errors remain in the Message Area SF 20 8 Settings Guide 20 8 1 Com mon Settings Guide D Script page 20 50 GP Pro EX Reference Manual 30 11 Continued Errors Displayed while Error Checking Error Message Handling method Reference The no of addresses used by Global D Script exceeds the limit The excess part will not be executed Make sure the total number of addresses to use in Global D Scripts including calling functions does not exceed 256 by creating multiple scripts with the same trigger conditions and separating instructions The total no of Global D Scripts and functions exceeds the limit of 32 The excess code will not be executed Make sure the total number of Global D Script and functions does not exceed 32 by uniting multiple scripts with the same trigger conditions amp 20 9 Restric tions 20 9 1 D Script Global D Script Restrictions page 20 55 Global D Script Global D Script No has an error Invalid Expression Refer to the comments displayed in the Message Area use the Tool Box and the Built in
37. ve permission to access this file Check the PC s access privileges The above was during com munication You cannot communicate either because the cable is disconnected or because of noise Check the cable s surroundings and make sure that the cable is not severed and that no noise is occuring Do not use a USB exten sion cable etc The memory error occurred The PC s memory is insufficient Shut down another application or restart the OS and run the transfer tool again Failed to recognize the desti nation main unit Please con firm whether the model is supported by GP Pro EX or the transfer tool You are trying to transfer to a device that cannot be recognized by the editor Confirm whether or not the destination unit is a GP Failed to acquire the informa tion Either the system is not downloaded or the model is not supported Confirm whether the model is sup ported and transfer the main unit s system again A074 Settings Menu page 27 2 Invalid password Transmission was canceled The password cannot be checked The file may be damaged Please check it again in an area with no electrical noise Do not use a USB extension cable etc Failed to connect because the main unit was in communica tion with the transfer tool It is communicating with another com puter Wait until the communication finishes Failed to write data The file cannot be
38. ws in the text to be imported are within the range SS 15 6 Importing Exporting Registered Text Tables for Use with Different Projects 15 6 2 Setup Proce dure Import page 15 33 GP Pro EX Reference Manual 30 9 Errors Displayed on the Editor 30 1 27 Recipe Settings Error Message Cause and Solution Reference Failed to access the filing data CF Card and couldn t con vert it Please confirm the settings Verify that the data in the CF card Out put Folder has not become read only SF 67 Seeing the Project Information 6 7 2 Setup Procedure m CF Card Output Folder Setting Proce dure page 6 38 Failed to paste a part of infor mation The paste range and the range of the data to be pasted may be different Check the content of the data to be pasted Failed to read the target file The specified data may be damaged Check the data in the CF card Output Folder SF 67 Seeing the Project Information 6 7 2 Setup Procedure m CF Card Output Folder Setting Proce dure page 6 38 Cannot create an index file because no CSV file has been created Try again after creating the CSV file SF 25 11 Transfer CSV Data Setup 25 11 3 Condition Name Search Fea ture What is the Index File page 25 99 Failed to read a part of data because unwanted data exists in the target file The target file has data out of the spec ification range Reco
Download Pdf Manuals
Related Search
Related Contents
Philips SWL6160H Vol.7 (1998/07/06 発行) Analox O2NE/O2He User Manual RGBW 4IN1 10W12Leds Indoor Wall Washer User Manual Sistema Pistas Deportivas switchmaster - Market Central Inc MX7 Guia do usuário - Honeywell Scanning and Mobility Black & Decker CM2020R Use & Care Manual Machines hostiles - Syndicat CGT des Finances Publiques Copyright © All rights reserved.