1. 220i 773938a en zul Sol epig UNIT YE 0 0000 m lin ft possede Imm m be UNIT A EET ul 851 BEZ bo la e Stanley TLM 220i Das TLM 220i We VY 77 116 Complies with 21 CFR 1040 10 and 1040 11 expect for deviations pursuant to Laser Notice No 50 dated June 24 2007 www stanleyworks com TE 2x AA Power 3V 0 6A Made in Austria STANLEY 2011 Stanley Europe Egide Walschaertstraat 14 16 2800 Mechelen Belgium http www stanleyworks com
2. PI C key or the key Parallax errors occur when the digital pointfinder is used on close E m the laser dot may appear displaced in the crosshair In this case you should rely on the actual laser dot for targeting the object See drawing F 2 Zoom step 1 2x 4x 2 3 Level in 4 Crosshairs 5 Inclination angle 6 Distance tracking value 7 Image Menu functions Settings Various device settings be made the menu vertical list shows each entry In this menu the selection field cursor remains stationary and the list moves in a vertical direction Starting from the centre of the list the priority of list entries starts at the top and fans out clockwise See drawing G The menu contains following items Units of measurement distance Units of measurement angle Beep Digital Pointfinder image in black white Reset Calibrate tilt sensor N DO UBB WN Level in status field in 8 Offset 9 Tripod 10 Display illumination Navigation in the menu The menu allows settings to be customized for a particular user or applica tion General description Press and hold the key to enter the Setup menu By pressing the Or 2 keys navigate through the main menu items in the menu Press the key briefly to enter the submenu of the selected main y y menu item By pressing the or keys you can make the alterations the submenu Press and hold the key to accept
3. about the measurement of the partial lengths and Storage of constants historical storage Storage of a constant You can store and recall a frequently used value e g height of a room Measure the desired distance press and hold the button until the device beeps to confirm storage Recalling the constant HIST Press this button twice to recall the constant and then press the button to enter it into your calculation Historical storage Press this button once and the previous 20 results measurements or calculated results are shown in reverse order The and buttons can be used for navigation Press this button to use a result from the summary line for further calculations Pressing the and buttons at the same time erases all the values in historical storage Stanley TLM 220i 773938 en Functions E Long range Mode 17 Press the key The symbol is displayed Unfavourable conditions strong sunlight or a very weak reflective target surface may reduce the range of the device in spite of this the long range mode allows you to take measurements over longer distances The use of a tripod and measurement initiation by pressing the key are recom mended when measurements over 30m are made over longer time periods in these conditions For details see Technical specifications CE settings are reset when the device is switched off Timer self triggering Press this button to set a 5
4. contains the individual measurements of the measuring program with reference to a series of separate distance measu rements Three lines are provided for this A horizontal line separates the measurement field and the result bar from one another A red triangle PE indicates whether the selected measuring program has a detailed display available Program selection with measurement instructions Program selection submenu Level Timer Measurement field Result bar Detailed display N AE UBB WN Status bar with Laser ON Reference plane Display Long range mode Offset Plus Minus Battery status Display in digital pointfinder mode Digital pointfinder 4x zoom The device has an integral digital pointfinder which shows the target directly on the display The displayed crosshairs allow precise measu rements to be made even though the laser beam is not visible See drawing F 2 The integral coloured digital pointfinder is a great help outdoors and can be used in every function Longer distances and precise measurements on detailed surfaces can even be accomplished in bright sunlight without any problem The 4x zoom allows the image to be magnified to suit the user s requi rements Press the key to activate the function Press the key again to operate in 1 2x or up to 4x zoom view The brightness of the camera can be adjusted through 5 levels using the Stanley TLM 220i 773938a en Start up
5. subtracted from the previous one This process can be repeated as required Press this button and the result is then always shown in the summary line with the previous value in the second line The last step is cancelled Area gt Press once The lt gt symbol appears the display Press this button to take the first length measurement gt e g length Press it again to take the second length measurement Z2 e g width The result is shown in the summary row Press and hold the key to display the perimeter gt Volume Press this button twice The 9 symbol appears in the display Q Press this button to take the first length measurement 9 e g length O Press this button to take the second length measurement Gi e g width C Press this button to take the third length measurement e e g height The result is shown in the summary row Press and hold the button to display additional room information such as ceiling floor area e surface area of the walls Ss circumfe rence gt Trapezium measurement See drawing J Press the a key once The symbol is displayed Press the O key and take the first length measurement e g height Press the C key again and take the second length measurement e g width Press the Q key and take the third length measurement e g height 2 The result is shown in the summary row Press and hold the d key to d
6. the settings Pressing the button for longer in the menu allows you to quit the settings function without saving Menu functions DEBE Stanley TLM 220i 773938a en Setting the unit for distance measurements The following units can be set Distance LI 0 0000 m 1 3 0 00 e Joon re Jo oon He foan un an Volume 0 000 m 0 000 m 0 000 m 0 000 m 0 00 ft 0 00 fe 0 000 yd 0 000 yd 0 000 yd Setting the unit for tilt measurements The following units can be set for tilt measurements Display illumination The brightness of the display has six levels of adjustment Step 6 is the brightest and step is the darkest setting Measuring with the tripod A0 The reference point may be adjusted to the tripod mount if the user requires a measurement from the actual mounting grommit versus the front or back of the Stanley TLM To do this select the symbol in this menu item You can switch the reference on the tripod on or off The setting can be seen on the display 1 l C We recommend that measurements are initiated using the key when using the device on a tripod in order to prevent loss of sharp ness CE The settings are reset when the device is switched off Beep 441 You can switch the beep on or off Offset 24 offset adds subtracts a specified value automatically to or from all measurements This function allows tolerances to be taken into account e g un
7. 71 116 FRU LASER MEASUREMENT ZO Stanley TLM 220i 000 0007 000 000 000 000 000 000 User Manual English Congratulations on the purchase of your Stanley TLM 220i A Ww ensure that all users understand these directions and adhere to them Safety InstructiOns aavenveneensenneenenansenseneeeneens Carefully read the Safety Instructions and the User Manual before using this product The person responsible for the instrument must SCI De eaten eenen 4 Menu functions aaneen enneenseeneeensensenseensenneensennen 6 innen 8 63S UFITIB een 9 EUMECES me EEE 9 AD PME ee 14 Safety Instructions Symbols used The symbols used in the Safety Instructions have the following meanings WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or in appreciable material financial and environmental damage C amp Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Use of the instrument Permitted use e Measuring distances e Computing functions g areas and volumes e Measuring tilts Prohibited use e Using the instrument without instru
8. ction e Using outside the stated limits Deactivation of safety systems and removal of explanatory and hazard labels e Opening of the equipment by using tools screwdrivers etc as far as not specifically permitted for certain cases e Carrying out modification or conversion of the product e Use of accessories from other manufacturers without the express approval of Stanley Stanley TLM 220i 773938a en Safety Instructions e Deliberate or irresponsible behaviour scaffolding when using ladders when measuring near machines which are running or near parts of machines or installations which are unprotected e Aiming directly into the sun e Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site e g when measuring on roads construction sites etc Limits of use The Stanley is designed for use in areas permanently habitable by See section Technical Data humans do not use the product in explosion hazardous areas or in aggres sive environments Areas of responsibility Responsibilities of the manufacturer of the original equipment Stanley Europe Egide Walschaertsstraat 14 16 2800 Mechelen Belgium for short Stanley Stanley is responsible for supplying the product including the User Manual and original accessories in a completely safe condition Responsibilities of the manufacturer of non Stanley acces sories CS ma
9. ensor is calibrated Switching on and off Switches on the instrument and laser The display shows the battery symbol until the next button is pressed Pressing this button for longer switches the instrument off The instrument switches off automatically after six minutes of inactivity CLEAR button The last action is cancelled While making area or volume measu rements each single measurement can be deleted and remeasured in series Reference setting The default reference setting is from the rear of the instrument Press this button to take the next measurement from the front edge r A special beep sounds whenever the reference setting is changed After a measurement the reference returns automatically to the default setting rear reference See figure H Press this button for longer the front reference is set permanently Press this button the rear reference is set again Operation DEBE Stanley TLM 220i 773938a en Measuring Single distance measurement Press to activate the laser Press again to trigger the distance measu rement The result is displayed immediately Minimum maximum measurement This function allows the user to measure the minimum or maximum distance from a fixed measuring point It can also be used as determine spacings See figure 1 It is commonly used to measure room diagonals maximum values or hori zontal distances minimum values Q Press and hold down this b
10. finished dimensions compared with finished dimensions If you selected the Offset function in the menu you can now adjust the value using the or the key Pressing the key for longer increases the rate of change of the values When you reach the desired offset value confirm it with the key The display shows the appropriate symbol EN or IN for as long as the offset value is set Digital Pointfinder image black white The display in pointfinder mode can be changed to black white Stanley TLM 220i 773938a en Menu functions Level in status field Ez The Level in in status field can be switched on or off Reset returning the instrument to the factory settings 7 RFRFT The instrument has a Reset function If you select the menu function Reset and confirm the device returns to the factory settings and stack and memory are deleted CE All customised settings and stored values are also lost Calibrate the tilt sensor You can calibrate the tilt sensor in the device Calibration requires two measurements on a level surface Select calibration mode in the menu t Carry out a first measurement QO on a level surface The device confirms the measurement with 2 Rotatethe device horizontally through 180 E 3 Press the key and confirm that the device was rotated through 1807 4 Press the O key and take the second measurement The device confirms the measurement with lh The tilt s
11. he instrument It is a Class 2 laser product in accordance with e o EC60825 1 2007 Radiation safety of laser products Laser Class 2 products Do not stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afforded by aversion responses including the blink reflex WARNING Looking directly into the beam with optical aids e g binoculars telescopes can be hazardous Stanley TLM 220i 773938a en 3 Safety Instructions Precautions Do not look directly into the beam with optical aids CAUTION Looking into the laser beam may be hazardous to the eyes Precautions Do not look into the laser beam Make sure the laser is aimed above or below eye level particularly with fixed installations in machines etc Labelling Laser Radiation Do not stare into the beam Laser class 2 acc IEC 60825 1 2007 Maximum radiant power lt ImW Emitted wavelength 620 690nm Beam divergence 0 16 x 0 6 mrad Pulse duration 10795 2 Position of the product label see last page Start up Inserting replacing batteries See figure A Remove battery compartment lid and attach handstrap 2 Insert batteries observing correct polarity Close the battery compartment again Replace the batteries when the symbol flashes permanently in the display C amp Remove the batteries before any long period of non use to avoid the danger of corrosion CE Use alkal
12. ight sunlight or when measuring to poorly reflecting or very rough surfaces Measuring accuracy between 10 m and 30 m may deteriorate to approx 0 025 mm m for distances above 30 m to 0 1 mm m In long range mode the maximum deviation from a distance of 30 m increases to 0 15 mm m Operation Measuring conditions Measuring range The range is limited to 200 m At night or dusk and if the target is in shadow the measuring range without target plate is increased Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties Target surfaces Measuring errors can occur when measuring toward colourless liquids e g water or dust free glass Styrofoam or similar semi permeable surfaces Aiming at high gloss surfaces may deflect the laser beam and lead to measu rement errors Against non reflective and dark surfaces the measuring time may increase Stanley TLM 220i 7739382 en EN Appendix E Care Do not immerse the instrument in water Wipe off dirt with a damp soft cloth Do not use aggressive cleaning agents or solutions Handle the inst rument as you would a telescope or camera Warranty The Stanley TLM 220i comes with a two year warranty from Stanley More detailed information can be found at www stanleyworks com All illustrations descriptions and technical specifications may be subject to change without prior notice Appendix Stanley
13. ine batteries or rechargeable batteries only Changing the reference point multifunctional See figure B The instrument can be adapted for the following measuring situations e o For measurements from an edge fold out the positioning bracket until it first locks in place See figure measurements from a corner open the positioning bracket until it locks in place then push the positioning bracket lightly to the right to fold it out fully See figure D A built in sensor automatically detects the orientation of the positioning bracket and adjusts the zero point of the instrument accordingly Stanley TLM 220i 773938a en Keypad See figure E ON On measuring button 2 Digital pointfinder button 3 Long range button 4 Plus button 5 Functions button 6 Minus button 7 Area volume button 8 Menu Equal button 9 Indirect measurement Pythagoras button 10 Timer button Il Trapezium button 12 Storage Memory button 13 Reference button 14 Triangular area button 15 Clear Off button Display in normal mode See drawing F I The graphics screen of the measurement window is split into different areas Top left is the brightest field which contains the currently selected measuring program Just to the right appears the program submenu which shows the measuring programs that can be selected by pressing the same key the required number of times The measurement field
14. isplay additional information about the CL x trapezium measurement for example inclination angle A trapezium Functions to Stanley TLM 220i 773938a en Trapezium measurement 2 7 See drawing K Press the a key twice This symbol K is displayed Press the key and take the first length measurement K Press the C key and take the second length measurement 1 and inclination angle measurement Ce The device measures inclination angles between 45 and 45 The result is shown in the summary row Press and hold the a key to display additional information about the trapezium measurement for example inclination angle trapezium 5 area A Tilt measurement The inclination sensor measures tilts between 45 The infocode i 160 means that the device has been set outside the permissible limits During tilt measurement the instrument should be heldwithout a transverse tilt max 10 44 44 If the device is tilted by more than 10 laterally the display shows infocode i 156 which means that the device has been tilted too much The units of inclination are set in the menu Press this button once to activate the tilt sensor The x symbol appears in the display The tilt is continuously shown as or depending a on the setting Press to measure the inclination and the distance See figure L Direct horizontal distance Press this button
15. istance of 0 1m from the next stake out point The arrows in the display Zn indicate in which direction the Stanley TLM needs to be moved in order to achieve the defined distance either a or b As soon as the staking out point is reached the symbol appears in the display The function can be stopped at any time by pressing the button Triangular area The area of a triangle can be calculated by the measurement of three sides See drawing N Press the key once the triangle symbol f appears in the display Press the key and measure the first side of the triangle f Press the Q key and measure the second side of the triangle is Press the Q key and measure the third side of the triangle A The result D is shown in the summary row Press and hold the key to display additional information about the measurement such as the angle included by the first two measu rements and the perimeter N of the triangle ndirect measurement The instrument can calculate distances using Pythagoras theorem This procedure is helpful if the distance to measure can not be reached directly Cg Make sure you adhere to the prescribed sequence of measu rement e All target points must be in a horizontal or vertical plane best results are achieved when the instrument is rotated about a fixed point e g with the positioning bracket fully folded out and the instrument placed on a wall or the Stanley TLM is moun
16. ll appears Hardware error then your instrument is defec tive Please call your dealer for assistance Appendix Stanley 220i 773938a en Technical data Distance measurements Measuring accuracy up to 10 2 o standard deviation Range use target plate from about 100 m 0 05 m to 200 m Smallest unit displayed v Minimum maximum measurement Conti nuous measurement Area volume calculation of room data DEE sre Addition subtraction y Indirect measurement using Pythagoras Tilt measurements Tilt sensor Accuracy 2 standard deviation to laser beam to the housing Indirect measurement using tilt sensor P direct horizontal distance Angle measurement using tilt sensor y 45 typically 1 0 mm General Laser class 635 nm lt mW 6 30 60 mm 10 50 100 m after 3 min Laser type laser point at distances Autom laser switch off Autom instrument switch off Display illumination Multifunctional endpiece Timer self triggering Save constant value Tripod thread Type 1 4 20 Battery life up to Type AA 2x 1 5V 5 000 measurements Protection against splashes and dust IP 54 dust proof splash proof 435x 55 30mm Weight with batteries 195 g Temperature range Storage 25 C up to 70 C 13 F up to 158 F 10 C up to 50 C 14 F up to 122 F maximum deviation occurs under unfavourable conditions such as br
17. nufacturers of non Stanley accessories for the Stanley TLM are responsible for developing implementing and communicating safety concepts for their products They are also responsible for the effectiviness of these safety concepts in combination with the Stanley equipment Responsibilities of the person in charge of the instrument WARNING The person responsible for the instrument must ensure that the equipment is used in accordance with the instructions This person is also accountable for the deployment of personnel and for their training and for the safety of the equipment when in use The person in charge of the instrument has the following duties To understand the safety instructions on the product and the instruc tions in the User Manual Tobefamiliar with local safety regulations relating to accident preven tion e inform Stanley immediately if the equipment becomes unsafe Hazards in use CAUTION Watch out for erroneous distance measurements if the instrument is defective or if it has been dropped or has been misused or modified Precautions Carry out periodic test measurements Particularly after the instrument has been subject to abnormal use and before during and after important measurements Make sure the Stanley TLM optics are kept clean and that there is no mechanical damage to the bumpers CAUTION In using the instrument for distance measurements or for positio ning moving objects e g crane
18. r the product yourself In case of damage contact the local dealership FCC statement applic in U S This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help WARNING Changes or modifications not expressly approved by Stanley for compliance could void the user s authority to operate the equipment Laser classification Integrated distancemeter The Stanley TLM produces a visible laser beam which emerges from the front of t
19. s building equipment platforms etc unfo reseen events may cause erroneous measurements Precautions Only use this product as a measuring sensor not as a control device Your system must be configured and operated in such a way that in case of an erroneous measurement malfunction of the device or power failure due to installed safety measures e g safety limit switch it is assured that no damage will occur Safety Instructions ES AN Stanley TLM 220i 773938a en WARNING Flat batteries must not be disposed of with household waste Care for the environment and take them to the collection points provided in accordance with national or local regulations The product must not be disposed of with household waste Dispose of the product appropriately in accordance with the national regulations in force in your country Always prevent access to the product by unauthorised personnel Electromagnetic Compatibility EMC The term electromagnetic compatibility is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present and without causing electromagnetic interference to other equipment WARNING The Stanley TLM conforms to the most stringent requirements of the relevant standards and regulations Yet the possibility of it causing interference in other devices cannot be totally excluded CAUTION Never attempt to repai
20. second time delay or Press and hold down this button until the desired time delay is reached max 60 seconds Once the key is released with the laser activated the remaining seconds until measurement e g 59 58 57 are displayed in a countdown The last 5 seconds are counted down with a beep After the last beep the measu rement is taken and the value is displayed CS timer can be used for all measurements Appendix Message codes All message codes are displayed with either D or Error The following errors can be corrected Transverse tilt greater than 10 Hold the instrument without any transverse tilt Main tilt direction angle too Measure angle up to max 45 high gt 45 Calibrate the device on an abso The calibration has not been accomplished on a leveled lute horizontal leveled surface surface and the calibration value is respecitvely within an ineli gible area ar LEE Calculation error Repeat procedure Temperature too high Cool down instrument Temperature too low Warm up instrument Receiver signal too weak measurement time too long distance gt 100 m Received signal too strong Target too reflective use target plate 257 Wrong measurement back Darken target measure in diffe ground brightness too high rent lighting conditions 260 Laser beam interrupted Repeat measurement Use target plate Switch on off the device several times If the symbol sti
21. ted on a tripod e minimum maximum function can be used see explanation Measuring gt Minimum maximum measurement The minimum value must be used for measurements at right angles to the target the maximum distance for all other measurements Indirect measurement determining a distance using 2 auxilliary measurements See figure P e g for measuring building heights or widths It is helpful to use a tripod when measuring heights that require the measurement of two or three measurements Press this button once the display shows 2 The laser is switched on Q Aim at the upper point 1 and trigger the measurement a After the first measurement the value is adopted Keep the instrument as hori zontal as possible O Press and hold down this button to trigger continuous measurement A sweep the laser back and forth and up and down over the ideal target point 9 Press to stop continuous measurement 2 result is displayed in the summary line the partial results in the secondary line Press and hold the key to display additional information about the measurement of the angles of the triangle xl and ZA Functions Stanley 220i 773938a en Indirect Measurement determining a distance using 3 measurements See figure Q Press this button twice the display shows the following symbol Jl The laser is switched on Aim at the upper point 1 and trigger the measurement After
22. the first measurement the value is adopted Keep the instrument as horizontal as possible Q Press and hold down this button to trigger continuous measurement lt 4 sweep the laser up and down over the ideal target point Press to stop continuous measurement 2 The value is adopted Aim at the lower point and press this button to trigger the measurement 3 4 The result is displayed in the summary line the partial results in the secondary lines Press and hold the key to display additional information about for example the partial distances a l lt 4 Indirect measurement determining a partial value using 3 measurements 1 See figure R e g determining the height between point and point 2 using three target points lt lt Press this button three times the display shows the following symbol laser is switched on Aim at the upper point 1 Q Press this button and trigger the measurement JA After the first measurement the value is adopted Triggers the measurement 4 After the second measurement the value is adopted and the minimum distance ram QO Press and hold down this button to trigger continuous measurement 1 Sweep the laser up and down over the ideal target point O Press this button to end continuous measurement The result is displayed in the summary line the partial results in the secondary lines Press and keep pressed the lt key to BeOne information
23. twice and the following symbol appears in the display A Press this button to measure tilt and distance The summary line displays the result as the direct horizontal distance Press and hold the key to display additional information about the measurement for example the inclination angle 1 the measured distance A and the indirect height 21 See drawing Stake out function LIE Two different distances a and b can be entered into the instrument and can then be used to mark off defined measured lengths e g in the const ruction of wooden frames See figure O Entering stake out distances Press this button three times and the stake out function symbol appears in the display Le By using and you can adjust the values first a and then b to suit the desired stake out distances Holding the buttons down increases the rate of change of the values Once the desired value a LI has been reached it can be confirmed with the button Value b ILE can be entered using and The defined value b is confirmed with the button Pressing the button starts the laser measurement The display shows Stanley TLM 220i 773938 en Functions m required stake out distance in the summary line between the stake out point first a and then b and the instrument rear reference If the Stanley TLM is then moved slowly along the stake out line the displayed distance decreases The instrument starts to beep at a d
24. utton until you hear a beep Then slowly sweep the laser back and forth and up and down over the desired target point e g into the corner of a room Press to stop continuous measurement The values for maximum and minimum distances are shown in the display as well as the last measured value in the summary line Laser continuous 5 Press and hold down the key when switching on the device until the character appears permanently in the display and a beep sounds Every further press of the key releases a distance measurement Press the key and keep it pressed to switch the device and Laser continuous operation off Stanley TLM 220i 773938a en If the laser is in continuous operation mode the device switches off automatically after 15 minutes Functions Overview of the program icons Measurement Detail display 1 2 3 2 3 Measuring program Simple distance measure e lees s nn a l 2 999292 J 53 9 02 3 Bla N 3 z al 3 2 Jj E ol 9 E 3 t S s 3 3 d 8 3 5 01 e 5 er using three distances Trapezoid measurement 2 using two distances and one angle Pythagorean calculation Pythagorean calculation Pythagorean calculation Inclination measurement Direct horizontal distance Measuring Addition subtraction Distance measuring The next measurement is added to the previous one The next measurement is