Home

s. & as ltd universal programmable scrolling lcd user`s manual

image

Contents

1. Control panel buttons 1 Update to update the modified parameters on the UniLCD 2 Load from file to load the UniLCD parameters from your saved file 3 Save to file to save your modified parameters and messages in the target file 4 Refresh to reload the UniLCD parameters 5 Factory Reset to reset to Factory Settings
2. 1 1 TECHNICAL DATA Supply voltage Board supply 22Vdc 15 25 Input active voltage level is 22Vdc for A B C D and E inputs OVdc for arrows when ALo is set to Yes 22Vdc for arrows when ALo is set to No Connection Screw type plug in connectors Screen 88mmx49mm Case 113mmx81mmx34mm Inputs Dimensions 2 FUNCTION DESCRIPTION The content of the memory corresponding to the floor set by the gray or binary set by Ind inputs is displayed GF B1 M 1 Every change on the floor information inputs triggers the scrolling of the display to reflect the content of the newly selected floor The scrolling direction depends on the elevator direction and on the Sdr setting Arrows are also shown on the display 2 1 SETTING AND ACCESSING THE MENU To access the parameters menu press the SELECT OK push button You will be prompted to enter a password The password consists of 3 digits It is provided by S amp A S Co Ltd It is referred to as client password The first digit on the left starts blinking Use the NEXT DEC push button to decrement the digit and the PREV INC push button to increment the digit When the desired digit is reached push the SELECT OK push buiton The digit is accepted and replaced by The next digit starts blinking Repeat the above procedure for the remaining 2 digits If you have entered the right password access to the menu will be granted Otherwise access will be denied Once you entered the
3. A S amp A S LTD UNIVERSAL PROGRAMMABLE SCROLLING LCD Beirut Office Boutros Building 17 Basement Cheikh el Ghabi Street Ghabi Beirut 2068 7808 Lebanon Tel 961 1 216 994 Fax 961 1 339 600 GEHEIT Ed GETT Eet GE REF UNILCD V1 0 USER S MANUAL FOR S W VERSION 1 00 1437 Headquarters amp Factory S amp A S Building Seaside Road Jieh Chouf Lebanon Tel 961 7 996 333 Fax 961 7 996 116 Website www sascontrollers com Technical Support amp Email Tel 961 71 996 333 support sascontrollers com 1 GENERAL DESCRIPTION BS WE ren E E 2 FUNCTION DESCRIPTION 2 1 SETTING AND ACCESSING THE NIN EE 22 FLOOR CONF KGORA TION EE 2 3 DISPLAY ER EE 24 FLOOR QREE FING ME SACE EE 3 INSTALLATION AND MOUNTING SING TALEA TON enea E E E EAA TAER LEE 4 INSTALL UNILCD DRIVER AND DESKTOP APPLICATION 4 1 INSTALLING THE UNILOD DRIVER E 4 2 INSTALL DESKTOP APPLICATION e o cicveiaet cecirntesecetecpncasd cousecsteleremeodeutedaaumnetectedoadmaeies 5 EXECUTE THE UNILCD DESKTOP APPLICATION 1 GENERAL DESCRIPTION The UNILCD is a universal scrolling display for the elevator floor information It is capable of handling up to 32 floors with the possibility of editing and modifying the display contents for each floor It has a 28x17 pixels graphic display Three push buttons are provided to access the menu and change the display contents of each floor as well as modify the display configuration and function
4. enter the whole floor message aw is entered to end the greeting message 0 To exit the floor messages scroll to FOO and Press NEXT DEC or scroll to F31 and Press PREV INC to show FLr MES page A OONOOA 2 5 SPECIAL MESSAGES When a S amp A S controller is connected to UNILCD and the display type is set to enhanced six different special messages will be displayed according to the lift status The language of these messages is selected by Lng 1 English Wait Maintenance out of service call maintenance evacuation over load 2 French Attendre Revision Hors service Appeler service Evacuation Charge max 3 Swedish Vanta Service Out of service Call maintenance evacuation overlast 4 Spanish Espere un momento En mantenimiento Fuera de servicio Llamar a mantenimiento evacuacion Sobrecarga 3 INSTALLATION AND MOUNTING 3 1 INSTALLATION Connect terminals P and GND to power supply Connect terminals A B C D and E of the UNILCD board directly to A B C D and E of the controller board Connect terminals UP and DOWN of the UNILCD board directly to UP and DOWN arrow of the controller board 3 2 MOUNTING Mounting plate thickness 0 8mm to 5mm Cutout in mounting plate 111mmx71mm No need for welded studs screws 4 INSTALL UNILCD DRIVER AND DESKTOP APPLICATION 4 1 INSTALLING THE UNILCD DRIVER In order to install the application on a computer a CD is provided by S amp A S Ltd and the below steps shal
5. menu the PREV INC and NEXT DEC push buttons are used to scroll up and down respectively in the menu list Pressing the SELECT OK push button will edit the value of the parameter displayed Use the PREV INC or NEXT DEC push buttons to respectively increase or decrease the value Press the SELECT OK push button to save new value Following is a description of the parameters a Factory Display Description Range setting an Sets the contents to be displayed for each floor GF to 31 Selects the greeting messages according to the location of the SMS UniLCD cabin or hall or disables greeting messages all Dis Hal Cab Dis together For hall with wide or long selection hall greeting message will be displayed when both arrows are inactive For hall with double selection hall greeting message will be displayed all the time For cabin with wide or long selection no hall greeting MES message is displayed 39 Characters Welcome For cabin and double selection hall greeting message will be displayed when one of the arrows is blinking If the message is shorter than 39 characters it can be ended by entering CR d Sets the delay in seconds to display the greeting message MET when both arrows are inactive Applicable only for hall with 5 to 99 10 sec wide or long selection 1 REFER TO SECTION 2 1 TO ACCESS ALO SETTING REFER TO SECTION 2 3 FOR MORE DETAILS D Factory Display Description Range setting For cabin selection greeting message of eac
6. Finish to exit Setup 5 EXECUTE THE UNILCD DESKTOP APPLICATION 1 Run the application 2 Plug in your UniLCD A notification sounds up indicating that your Windows recognized your device successfully Click on the refresh button Your device name along with the com port number will appear in the box 9 3 Click on your device name Enter your UniLCD password Press ok button to configure its parameters 10 if your password is correct the UniLCD parameters tab will open e Below is the configuration parameters panel Fir Cfg EE as Disables Selects greeting messages according to UniLCD location MES KE Fir MES Greeting message of each floor MET Hall greeting message delay in seconds 105 cu ws Sets the display contrast Sdi Sets the scroll direction Alo When yes is selected Up and Down arrows become active low ina l Selects the floor coding Gray A LCo Selects the display color White LCN l l Selects the display configuration Wide Ge Lng Sets the language Sets the number of basements and update the floor configuration accordingly Mez Indicates the presence of mezzanine floor and update the floor confguration accordingly Fip Flips display upside down Adjusted according to viewing angle 11 Floor configuration values can be modified Greeting messages adjusted to be displayed according to your UniLCD type Weeome pen Weeome welome mom r
7. and select FLr CFg to change the configurations of the floors 3 The display will show the first floor number on line 1 The corresponding memory content is shown on the second line Use the NEXT DEC or PREV INC push button to scroll to the desired floor 4 5 10 Press the SELECT OK push button The leftmost character of the memory content of this floor starts blinking Use the NEXT DEC or PREV INC push button to scroll to the desired leftmost character 0 9 blank B S G E F M L Press the SELECT OK to save the leftmost character content The rightmost character starts blinking Use the NEXT DEC or PREV INC push button to scroll to the desired rightmost character 0 9 blank B S G E F M L Press the SELECT OK to save the rightmost character content To exit the floor configuration scroll to FOO and Press NEXT DEC or scroll to F31 and Press PREV INC to show FLr CFg page 2 3 DISPLAY CONFIGURATION The character display color can be white or blue Selection is done by LCo The display has 3 configurations 1 Horizontal wide Selection by setting LCn to Wid The display is mounted horizontally and uses the full screen to show the floor information in big characters Arrows are shown on the side When a greeting message is displayed the screen will be splitted into two horizontal lines Vertical Selection by setting LCn to Lng The display is mounted vertically and uses the full screen to show th
8. e floor information in big characters Arrows are shown on top and bottom REFER TO SECTION 2 5 FOR MORE DETAILS 5 3 Horizontal with 2 lines Selection by setting LCn to Dbl The display is mounted horizontally It uses first line to show the floor information The second line is used for the greeting messages Arrows are shown on the side of first line The display can be flipped upside down according to the viewing angle Selection is done by Flp To elaborate for Wid and Dbl flip should be set to Yes for eye level or lower mounting Moreover for Lng configuration flip should be set to Yes for right hand side mounting 2 4 FLOOR GREETING MESSAGES The greeting message content of each floor can be modified by following the steps below 1 Make sure that the display is powered it should show the memory content of the currently selected floor 2 Enter the menu and select FLr MES to change the content of the greeting message of each floor 3 The display will show the first floor number on line 1 The corresponding greeting message content is shown on the second line Use the NEXT DEC or PREV INC push button to scroll to the desired floor Press the SELECT OK push button The first character of the greeting message of this floor starts blinking Use the NEXT DEC or PREV INC push button to scroll to the desired character Press the SELECT OK to save the first character content The second character starts blinking Repeat the same procedure to
9. h floor will be displayed when both arrows are inactive or one of the arrows Fir is fixed l l MES For each floor a greeting message will be entered to be 39 Characters Welcome displayed If the message is shorter than 39 characters it can be ended by entering CR al Ctr Sets the display contrast 0 to 30 10 Sdr Sets the scroll direction Dn Up Non Dn ALo ee Yes is selected Up and Down arrow become active Yes No Yes Ind Selects the floor coding gra bin gra LCo Selects the character display color Whi Blu Whi LCn Selects the display configuration Wid Lng Dbl Wid Lng Sets the special messages language Eng Fre Swe Spa Eng Sets the number of basements B Once the basement number is selected the floors as i 0 to 9 0 configuration will be updated automatically The basements configuration will have B format Indicates the presence of one mezzanine floor Once the mezzanine is modified the floors configuration will be updated Mez automatically Yes No No When set to Yes the mezzanine floor is added with M configuration between GF and first floor Fip Flips display upside down it is adjusted according to the Yes No No viewing angle FSt Load factory setting Ext Exit menu 2 2 FLOOR CONFIGURATION The memory content of each floor can be modified by following the steps below 1 Make sure that the display is powered it should show the memory content of the currently selected floor 2 Enter the menu
10. l be followed 1 Run file SAS _Patch exe located in UniLCDDriver folder 2 Plug in the USB cable to the UniLCD device before turning power on 3 Turn onthe UniLCD device 4 2 INSTALL DESKTOP APPLICATION PROCESS 1 Run UniLCD_windows_1_0 application 2 Click next to continue the installation Welcome to the UniLCD V1 0 Setup Wizard This will install UniLCD V1 0 on your computer The wizard will lead you step by step through the installation Click Next to continue or Cancel to exit Setup install4j 3 Choose the directory you want to install then Next ZS Setup UniLCD VLO Select Destination Directory Where should UniLCD V1 0 be installed Select the folder where you would like UniLCD V1 0 to be installed then dick Next Destination directory c Program Files x86 UnilCD Required disk space 8 3 MB Free disk space 567 947 MB install4j 4 Select where the program shortcut should take place 4B Setup UniLCD V1 0 Select Start Menu Folder Where should Setup place the program s shortcuts Select the Start Menu folder in which you would like Setup to create the program s shortcuts then dick Next Create a Start Menu folder Java VEVEMOOMENT K Create shortcuts for all users install4j Completing the UniLCD V1 0 Setup Wizard Setup has finished installing UniLCD V1 0 on your computer The application may be launched by selecting the installed icons Click

Download Pdf Manuals

image

Related Search