Home
User Manual
Contents
1. lt www digiockhomesecurity com gt 2 Click on the Register button Figure 1 ee Fill in the requested information Figure 2 4 Once you have filled out the required information on the Registration page click Register and re enter your information to login to view data 5 To verify your information click on the User Information tab Here you can change and update g Porter Limi ECE 7 npe aga TaT your information and passwords at any point in time Updates occur instantaneously Figure 3 Figure 2 Figure 3 hete arar FER 477 ke Dea Teen Pute e BCE sT Sase Dha Tome ECE 477 Digital Systems Senior Design Project Rev 8 09 How to Use Your DHS System Central Monitoring Station CMS 1 After registering your system on the website you can use the keypad on the CMS to control the state of your device The system let you choose among 4 different commands Deactivated code D only the smoke sensor is on green light on the RSU Activated code all the RSU s sensors are on red light on the RSU Test code G check the sirens of the system with a smoke alarm test Admin code 4 change the CMS password default CMS password 1234 the CMS password is different from your login password you need to be in the Deactivated mode to change the CMS password 2 To change from one state to another enter the command code followed by the CMS password Then press Enter 7 PASSWORD Exam
2. A
3. ECE 477 Digital Systems Senior Design Project Rev 8 09 Digijock Home Security User Manual Congratulations on your purchase The Digijock Home Security is a wireless alarm system that will protect your home or your small business from fire and burglary Consisting of multiple remote sensor units RSUs and a central monitoring station CMS the system not only gives you the peace of mind of a safe home but it also gives you the power to control your home security system through a simple internet connection Enjoy safety and security for the 21 century and welcome to the Digijock Home Security family RSU features CMS features e Motion sensor e USB LCD based user interface e Noise sensor e USB keypad e Smoke sensor e USB siren alarm e Temperature sensor e XBee wireless module e Bicolor LED e Ethernet connection e Siren alarm e Atom Board e LCD based user interface e XBee wireless module e Backup battery e AC DC 9V electrical adapter NOT included but needed e Battery backup for CMS e A computer with an internet connection DHS Recycling Declaration For information regarding the recycling of this product please contact the company from which you originally purchased it Do NOT dispose of this with regular trash Caution e Be sure to check your alarm system at least once every six months e Replace your RSU s every 5 year e Impacts or drops can seriously compromise the device operations ECE 477 Digital Systems
4. Senior Design Project Rev 8 09 Product Description Central Monitoring Station CMS Components and dimensions 1 3 5 9x8 7x2 4 inches LxWxH 2 1 Power connection 2 Ethernet connection 4 3 USB LCD 4 USB Keypad 5 USB Speaker output 5 5 Remote Sensor Unit RSU 1 1 4 Components and dimensions 5 9x8 7x2 4 inches LxWxH 5 1 Bicolor LED 2 2 2 row LCD 16 characters 3 Microphone noise sensor 4 Power connection 3 6 5 Motion sensor 10m range 6 Speaker output 7 Photoelectric smoke sensor 7 ECE 477 Digital Systems Senior Design Project Rev 8 09 Setting Up Your DHS System Placement 1 Strategically place the two RSUs near possible entryways and fire hazards Make sure they are in the interior of the building and not in enclosed areas 2 Hang the two RSUs approximately 3 4 of the way up on the wall facing directly towards the area of interest It should be close to an electrical outlet Once all units are plugged in press the reset button on the back of each device 3 The CMS needs to be located near a place of common entry Again it is also necessary to place it by an electrical outlet It also requires an Ethernet connection Be careful The CMS does NOT have monitoring sensors You need an RSU placed in the same room Software Registration and Setup 1 On your computer please type the following web address into an Internet browser
5. ject Rev 8 09 1 Try plugging the device into a different outlet Try replacing the internal backup battery To replace the battery carefully open the RSU Locate the battery and replace it with an alkaline 9V battery 2 Try to test the smoke detector using the CMS Test state If the alarm does not turn on the problem is in the wireless communication It affects only noise and motion detection alarm 1 Try plugging the device into a different outlet 2 Unit must be replaced test the RCU it could be still functional and able to protect your house 1 Carefully clean the surface of all dust DO NOT use liquid 2 The problem could be either in the RSU or in the CMS Call manufacturer for maintenance 3 The device needs to be replaced Smoke noise or motion sensor 1 Device is damaged 1 The RSU needs to be replaced is not working 1 Internal software stall 2 The LCD 1s broken The LCD displays unexpected characters RSU 1 Internal software problem 2 LED broken The LED shows the wrong color or no color 1 Press the reset button on the back of the RSU try more than once if needed 2 The RSU needs to be replaced 1 Unplug and plug in the RSU Then press the reset button on the back 2 LED needs to be replaced the RSU is still functional if the LCD is on Digijock Home Security USA 123 Phaik St West Lafayette IN 47906 Phone 123 555 1234 Sy MADE IN THE U S
6. ple Activate alarms 911234 3 When entering the home and the alarm is Activated you have 15 seconds to deactivate the alarm otherwise the alarm will sound 4 To turn off the siren deactivate the system example 11234 Note in non alarm conditions the CMS and RSU will display the temperature of the room Web Server 1 The web server lets you control your alarm system from anywhere with a simple Internet connection After connecting to lt www digijockhomesecurity com gt and logging in to your account the User information page will display in the Current State window the state of your alarm system The same window lets you change the system state by using the drop down menu press the Update button after selecting Figure 4 2 If an alarm has been triggered the same page will show you which RSU and what sensor has been triggered The system will also use the email address and phone number you entered during registration to notify you of the emergency Figure 5 Figure 4 Figure 5 ECE 477 Troubleshooting Your DHS System The RSU doesn t produce noise 1 Lack of power the LCD 1s off as well 2 Bad communication with the CMS 1 Lack of power the LCD is off as well 2 Damage in the internal wiring The CMS doesn t produce noise 1 Dust on the lens 2 Bad wireless communication 3 Device damaged Motion sensor isn t working in Activated state Digital Systems Senior Design Pro
Download Pdf Manuals
Related Search
Related Contents
Mini IP Dome Camera User`s Manual Schwinn SR23 Assembly Manual Operação Symmetra® PX 2 Section 2 Connectors on the TR-LCD1900-ITX-DA タブレットPCと映像デバイスソリューション - 日本電気 Lab 5.2.3c Troubleshooting Interconnected Devices Avis Technique 16/13-677 TERMIFILM UV+ TERMIFILM 施工説明書 取扱説明書 StarTech.com 5.1 Channel PCI Surround Sound Card Adapter Copyright © All rights reserved.
Failed to retrieve file