User`s Manual - Tyson Bioresearch Inc.
Contents
1. glucose test result is number Milligram Per Deciliter Millimole Per Liter 3 You can press W or A to scroll forward or backward through the results When 000 appears on the dis play you have viewed all of the results in the memory Press W or Mto turn off the meter Note The meter will hold 500 results in the memory When the memory is full the oldest result will be re moved and replaced with the newest result Gee 1835 seg 308 F _ cc muri tl LOL UR 113 View control solution and day average result 1 Press M to turn on the meter The date and time will appear first Press M again to view the memory 2 Continue to press and release Y the control solution result the consecutive 7 14 30 days pre meal and post meal average results will be shown on display in order With the voice function on you will hear Premeal Postmeal num ber day average blood glucose test result is number Milligram Per Deciliter Millimole Per Liter S23 Me Mom 9 09 AM 1 dA y 7 JA y 1I nm nm ICI IMI IMI e mg dl amp mg dl 3 You can press Wor A to scroll forward or backward through the results When 000 appears on the dis play you have viewed all of the results in the memory Press W or M to turn off the meter Note if no control solution test has been performed pressing V will directly display day average results The consecuti
2. ini 29 Limitations of the Procedure 31 Service and Warranty iii 31 Customer Service 11ss arrese eee ie 33 Introduction Thank you for choosing the TysonBio AC100 Blood Glu cose Monitoring System As you already know self moni toring of blood glucose SMBG is a necessary part of the treatment plan of people with diabetes mellitus The Dia betes Control and Complications Trial DCCT has con firmed the significant benefits from SMBG when practiced as part of a larger intensive strategy to tightly control blood glucose concentrations Adapted for its ease of use and quick response time the TysonBio AC100 System has the ability to process accu rate results utilizing only a small volume of blood for in vitro diagnostics The TysonBio AC100 System is been designed with auto coding feature It means the meter will code itself auto matically every time you insert a test strip The voice guid ance feature with TysonBio AC100 system provides a aid for user with visually impaired to get safe accurate test results every time TysonBio AC100 Blood Glucose Monitoring System is in tesded for use in the home and in professional settings to monitor whole blood glucose levels obtained from the fingertip palm and forearm This is an over the counter OTC product Please read the entire User s Manual carefully before us ing this product About the Product Y
3. The HI alarm value range is 100 400mg dL 5 5 22 0mmol L default is 100mg dL 5 5mmol L Fig 9 3 LO alarm setting will appear Fig 10 With the voice function on you will hear Please set Hypoglycemic value To change this setting press 4 or W until you reach your desired LO setting and then press M to set Meter will turn off automatically you have now com pleted the meter alarm setting The HI alarm value range is 100 400mg dL 5 5 22 0mmol L default is 40mg dL 2 0mmol L a Lo dara aa eu iL Fig 9 gli Fig 10 nef Setting Up Voice Guidance 1 Press and hold A for 4 seconds with meter turn off to set voice function With the voice function on you will hear Please set voice guidance 2 The word on will appear on the display Press M to turn on the voice function pn or press W to display OFF and then tet press M to turn off voice function With the voice function on you will hear voice nce guidance on or voice guidance off ur 3 After setting the voice guidance func tion on L1 will appear on the display m4 Press A or W to choose langnage L1 ip 4 English or L2 Spanish and then press M to set Meter will turn off auto matically you have now completed the 4 voice guidance setting LL Unit Selection 1 Select unit mg dL or mmol L on the back Note The mg dL is the standard unit in the
4. Strip and Control Solution are in conformity with the IVDD 98 79 EC The Lancing device is in con formity with the MDD 93 42 EEC Manufacturer Tyson Bioresearch Inc 5F 22 Ke E Road III Science Based Industrial ParkChu Nan Miao Li County Taiwan R O C TEL 886 37 585998 EU authorized representative Medical Device Safety Service GmbH Schiffgraben 41 D 30175 Hannover Germany TEL 49 511 62628630 m The Lancets are in conformity with the MDD 93 42 EEC Manufacturer Wuxi Xinda Medical Device Co Ltd No 42 Xixin Road Zhangjing Town Wuxi Jiangsu 214194 China TEL 86 510 379 3149 EU authorized representative EMERGO EUROPE Molenstraat 15 2513 BH The Hague Netherlands Limitations of the Procedure Caution The TysonBio AC100 System is designed for in vitro diagnostic use only and is not intended to test on newborns Any change or administer of medication based on the TysonBio AC100 blood glucose test results without the consent advice of a physician or healthcare profes sional is not recommended The TysonBio AC100 test strips are designed for use with fresh capillary whole blood samples obtained from the fin gertip palm and forearm False results may occur when performing the test while severely dehydrated severely hypotensive in shock or in a hyperglycemic hyperosmo lar state If you believe you are suffering from any of the above symptoms consult a healthcare professional im mediately Service an
5. the test results from the meter The preset alarm is Press any button ringing to remind it to shut off or the is time to perform alarm will turn blood glucose test off automatically after 30 sec Other problems that may occur Action The test strip has not been Review the instructions and inserted into the meter re insert the test strip cor properly rectly white side face up Defective test strip Replace with a new test strip Insufficient blood sample Repeat the test with new test strip Test strip remains in the Meter will automatically test port for more than 3 turn off Re insert the test minutes prior to testing strip to the test port LCD display on the meter is blank when trying to perform a test Contact Customer Service for help Specifications Meter Operating Conditions Temperature Humidity Hematocrit Test Sample Sample Volume Measuring Unit Measuring Range Test Time Memory Capacity Average External Output Power supply Battery Life Dimension Weight 10 C 40 C 50 F 104 F 10 90 RH 35 55 Capillary whole blood from fingertip palm and forearm gt 0 5 pl mg dL or mmol L 20 600 mg dL 1 1 33 3 mmol L 5 sec 500 most recent results 7 14 30 days average results Standard RS232 PC interface two AAA batteries Approximately 1000 tests 94 x63 x25 mm 60 g without battery m The TysonBio AC100 Meter TysonBio AC100 Test
6. the results from the meter After finishing the data transfer press M button to turn off the meter Note While in the communication mode you will be unable to perform a blood glucose test If the meter is not in the PC link mode it will not respond to computer commands Care and Storage 1 Handle the meter with care Dropping or throwing the meter may cause damage to the device 2 Do not expose the meter test strips and control solu tion to extreme conditions such as high humidity heat freezing cold or dust 3 Always wash hands with soap and water and rinse and dry completely before handling the meter and test strips 4 When cleaning the meter gently wipe the exterior sur face using a damp soft cloth DO NOT USE ANY OR GANIC SOLVENT for cleaning 5 The meter should be stored at room temperature in a dry and clean space DO NOT STORE IN DIRECT SUNLIGHT OR AREAS WITH HIGH HUMIDITY AND OR DUST It is advised that you store the meter and its accessories into the provided carrying case For healthcare professionals using this system on multiple pa tient please be aware that all items that come in contact with human blood should be handled as potential biohazards Us ers should follow the guidelines for prevention of blood borne transmittable diseases in a healthcare setting for potentially infectious human blood specimens as recommended in the National Committee for Clinical Laboratory Standards Protec tion of Labor
7. United States Meters used in the United States must be set to read in mg dL Important Information You have to know before testing e Always keep the test strips in the original vial only Tightly close the vial immediately after removing a test strip e Do not use test strips and controol solutions beyond the expiration date printed on the package since this may cause inaccurate results e Use each strip immediately after removing it from the vial Each test strip can be used once e The sample must only be applied to the tip of the test strip e Any change or administer of medication based on the TysonBio AC100 blood glucose test results without the consent and advice of a physician or healthcare professional is not recommended e Low or high blood glucose readings can indicate a potentially serious medical condition If your blood glucose reading is unusually low or high or if you do not feel the way your reading indicates repeat the test with a new test strip If your reading is not consistent with your symptoms or if your blood glucose result is less than 60 mg dL 3 3 mmol L or higher than 240 mg dL 13 3 mmol L you should contact your healthcare professional and follow his or her treatment advice e Severe dehydration and excessive water loss may cause false low results If you believe you are suffering from severe dehydration consult your physician immediately Testing Your Blood Glucose Level Before testi
8. atically turn on Fig 10 With the voice function on you will hear meter power on music 3 All segments of the LCD display will ap pear a beep will sound and a clockwise jr 4 moving dotted lines will appear With the voice function on you will hear system checking 4 After system checking ok a flashing symbol will appear 7 With the voice function on you will hear Please ap ply blood sample S mg dl 5 Press and hold W for 4 sec to switch to control solution mode The ctl will ap pear which indicates that the meter will ctl mark your current test as a control solu tion test Now you are ready to apply the ai control solution With the voice function on you will hear Please apply control solution 6 Discard the first drop of control solution and squeeze a small drop of control so lution on a clean nonabsorbent surface such as a clean piece of wax paper Do not apply control solution to the test strip directly from the bottle 7 Bring the tip of the test strip to lightly touch the drop of Control Solution Con 523 908 trol Solution is automatically pulled into 4 0 the strip through the tip Hold until the E meter beeps The meter will now starts dai the countdown from 5 to 1 and the con trol solution test result will appear Fig 6 With the voice function on you will hear Control solution test result is num
9. atory Workers from Instrument Biohazards and Infectious Disease Transmitted by Blood Body Fluids and Tissue Approved Guideline NCCLS document M29 A ISBN 1 56238 339 6 Display Messages DISPLAY WHAT IT MEANS ACTION The system is ready to accept a blood sample The system is ready to accept a control solution sample appears when the result is HIGHER than the HI alarm setting reference range appears when the result is LOWER than the LO alarm setting reference range Test result is higher than 600 mg dL 33 3 mmol l You may now apply a blood sample You may now apply a drop of control solution sample For your refer ence or you can change the default setting value 100 mg dL according to page 9 For your refer ence or you can change the de fault setting value 70 mg dL accord ing to page 9 Repeat the test using a new test strip If the result is still HI consult your physician im mediately Temperature is high during the test procedure Temperature is low during the test procedure Temperature is too high to perform the test Meter speaks Operating temperature error Temperature is too low to perform the test Meter speaks Operating temperature error DISPLAY WHAT IT MEANS ACTION Test result is lower than 20 mg dL 1 1 mmol l Repeat the t
10. ber Milligram Per Deci liter Millimole Per Liter Caution Please remember that in order to prevent contamination follow the above instructions properly when performing the control solution test de Comparing Control Solution Results The TysonBio AC100 system is functioning properly if the result falls inside the specified range printed on the test strip vial If the test result falls outside the specified range repeat the test Results falling outside the specified range may be caused by e Error in performing the test e Control solution temperature is lower than 15 C 59 F or higher than 35 C 95 F e Expired or contaminated control solution e Expired or contaminated test strips e Meter malfunction Note The result will not be included in calculating the average when the meter is set in the control solution test ctl mode DO NOT use the system if the problem persists Please contact customer service Memory Features View results stored in the memory 1 Press M to turn on the meter The date and time will appear first 2 Press W to review previous results Results will be shown starting with the most recent Each result will show the date and time the test was taken If enough tests are performed and stored to calculate 14 day average result the screen will also display the 14 day average result With the voice function on you will hear Premeal Postmeal blood
11. d Warranty IMPORTANT Tyson Bioresearch Inc cannot endorse the performance of the TysonBio AC100 System when used with test strips other than those designed for the Tyson Bio AC100 meter The TysonBio AC100 System manufac turer warranty is valid only when used properly within the guidelines of the provided user s manual and is invalid when the TysonBio AC100 System and TysonBio AC100 test strip are used improperly Manufacturer Warranty Tyson Bioresearch Inc guarantees that this device will be free of defects in materials and workmanship for a period of three years from the date of original purchase During the stated three year period our company shall repair or replace any TysonBio AC100 meter found defec tive with a new TysonBio AC100 meter This warranty does not apply to the performance of a TysonBio AC100 meter that has been accidentally dam aged altered misused tampered with or abused in any way In no event shall our company be liable to the purchaser or any other person for any incidental conse quential or punitive damages arising from or in any way connected with the purchase or operation of the TysonBio AC100 meter or its parts For manufacturer warranty services purchaser must contact Tyson Bioresearch Inc for help Customer Service If you have any questions or concerns regarding this product or its operation or any attempt to correct a problem fails please call our customer service Our trained s
12. e You think your blood glucose is low e You are unaware of hypoglycemia e Your AST results do not match the way you feel e You are testing for hyperglycemia e Your routine glucose results are often fluctuating e If you are pregnant The Control Solution Test The control solution is used to check and ensure that the TysonBio AC100 system is working properly and that you are performing the test correctly When to Perform a Control Solution Test 1 When you are using your TysonBio AC100 system for the first time 2 When you are using a new batch of test strips 3 Anytime you question the performance of the system or on a regular basis to ensure accuracy e g once a week 4 When you adjust your diabetic medication plans 5 When your blood glucose test result is lower or higher than your normal level Note There are three control solutions at different desired range of aqueous glucose Low Normal or High For more information about the control solution please read your control solution package insert Two sets of control solution should be used a high level and a low level con trol solution of your choice For order information please contact customer service To Perform a Control Solution Test 1 Make sure the control solution is at room temperature 15 C to 35 C or 59 F to 95 F prior to testing 2 Insert a test strip white side face up contact bar s end first into the test port The meter will autom
13. ee Tys nBia TysonBio AC100 Blood Glucose Monitoring System User s Manual For in vitro diagnostic use only Table of Contents Introductioni la Reine bain 1 About the Product ini 2 About the TysonBio AC100 Meter 2 About the TysonBio AC100 Meter Display 4 About the TysonBio AC100 Test Strip 5 About the TysonBio AC100 Test Strip Vial 6 Installing Replacing the Battery 6 Setting Up the Meter rin 7 Setting Up the Date Time 7 Setting Up Reminder Alarm 8 Setting Up HI LO Alarm 9 Setting Up Voice Guidance 10 Unit Selection 10 Important Information nnna 11 Testing Your Blood Glucose Level 12 Preparing the Test Strip 12 Obtaining a Blood Sample 13 Applying Blood Sample to Test Strip 14 Available Alternate Sites Testing 16 The Control Solution Test rrnnn 17 Memory Features nre 20 Transfer Test Results to a Computer 23 Care and Storage 1rrrcererriiiii eee 24 Display Messages neri 25 Specifications
14. est using a new test strip If the result is still Low con sult your physi cian immediately Large varia tion may occur between results due to high or low tempera ture Move to the environment 10 40 C or 50 104 F and wait 15 minutes before re testing Repeat the test in a cooler setting 10 40 C or 50 104 F Wait 15 minutes before re testing Repeat the test in a warmer setting 10 40 C or 50 104 F Wait 15 minutes before re testing An error message indicating a prob lem with the test strip Meter speaks Strip error An error message indicating a prob lem with the meter Meter speaks Meter error Battery power is low Meter will pro vide approximately 50 more measure ments Battery power is too low for further usage All testing values recorded in the memory have been shown DISPLAY WHAT IT MEANS ACTION Review the in structions and try again with a new test strip Press reset but ton and check the meter again with the test strip If the problem persists contact customer service for help Replace with two AAA batteries Replace with two AAA batteries im mediately Press M or wait for 3 minutes to turn off the meter DISPLAY WHAT IT MEANS ACTION The meter is in the Follow the in PC commnuication structions provid mode ed in the software to download
15. he insert provided with lancing device 1 Unscrew and remove the endcap of the lancing device 2 Insert the lancet into the lancet holder 3 Twist and remove the protective lancet cover to expose the sterile needle tip 4 Recapping and screwing the endcap to the body of the lancing device 5 Pull back on the cocking mechanism until it comes to a stop 6 Place the lancing device firmly against the finger tip and press the release button 7 After sampling remove the endcap containing the used lancet carefully 8 Remove the lancet from the lancing device Discard the used lancet properly in accordance with local state and federal law Applying Blood Sample to the test strip 1 After obtaining a blood sample touch the tip of the test strip to the drop of blood Blood is automatically drawn into the test strip Hold the tip of the test strip touching the blood drop until the meter beeps 2 As soon as enough blood has filled the confirmation window see picture of the test strip the meter will starts the countdown from 5 to 1 Your blood glucose result will appear on the display and will be stored into the meter memory automatically With the voice function on you will hear Premeal Postmeal blood glucose test result is number Milligram Per Deciliter Millimole Per Liter 523 10 32 mM Note To ensure accurate results make sure the confir mation window of the test st
16. ied to the target area 3 Target Area This is where blood is drawn into the test strip About the TysonBio AC100 Test Strip Vial Vial Label Test Strip Vial TysonBio AC100 Blood Glucose Test Strips Store at 4 30 C 39 86 F Do not refrigerate Use within 90 days after first opening Do not store test strips outside this vial Use TysonBio AC100 meter only Re cap immediately 4 WARNING Always close lid tightly Lot H8T121205 39 86 F Do not refrige For testing of glucose in capillary whole blood EXP Aug 2011 t strips outside this vial For in vitro diagnostic use a ely Control Solution Range ys close fd tightly mmol l are Low 31 61 1 7 3 4 al lostic use Fan al 6607 565008 Normal 84 144 4 7 8 0 High 348 438 19 3 24 3 In 50 TEST STRIPS 3 it Sorco k chu Nan 37 505098 Lot Number BTRIPS Control Solution Range Expiration Date Essi Installing Replacing the Battery When the battery is low the meter will show a warning signal When this display appears it is time to replace a new bat L tery When the low battery warning signal is shown the meter will provide accurate results for approximately 50 more mea surements How to Replace the Battery 1 From the back of the meter gently slide and remove the battery cover 2 Insert the batteries with the and ends matching the marks in the battery compartment 3 Slide battery cover back
17. into place lt 108 Setting Up the Meter To turn the meter on first install the batteries then press the reset button located at the back of the meter and pro ceed with the following instructions Setting Up the Date Time 1 Press and hold M for 4 seconds with meter turn off to enter this mode With the voice function on you will hear Please set date and time 2 Press A or W to select 24hr or 12hr setting Press M to set Fig 1 3 The year will now appear and flash Press A or W to select the year Press M to set Fig 2 4 The number in the month position will now flash Press A or Y to select the month Press M to set Fig 3 5 The date will now flash Press A or W to select the date Press M to set Fig 3 6 The number in the hour position will now flash Press A or Y to select the hour Press M to set Fig 4 7 The minute will now flash Press A or W to select the minute Press M to set and meter will turn off automati cally You have now completed the meter date time setting Fig 4 Che ecg 5 23 Bet Fig 1 Fig 2 Fig 3 Fig 4 Setting Up Reminder Alarm TysonBio AC100 meter provides four user setting remind er alarms for worry free testing Default is alarm off 1 Press and hold W for 4 seconds with meter turn off to enter this mode With the voice function on you will hear Plea
18. ites testing AST This system provides you to test on the palm and the forearm with the equivalent results to fingertip testing There are limitations for doing AST Please consult your healthcare profes sional before you do AST Palm Forearm CAUTION 1 Physiologic differences in the circulation between the finger and other test sites like the forearm and palm may result in differences in blood glucose measure ments from the other test sites and your fingertips Changes in blood glucose may be observed in finger blood samples sooner than blood samples from the forearm and other alternate sites Rub the alternate test sites about 20 seconds before lancing If you are testing for hypoglycemia low blood glucose or if you suffer from hypoglycemia unawareness we recom mend that you test on your fingertips 2 Talk to your doctor to see if alternate site testing is right for you With a little bit of education you can give your fingertips a rest and maybe test more often than you do now For people with diabetes more frequent test ing is a good thing Just remember any time you want to be sure of an accurate up to date blood glucose reading test on your fingertip 3 We strongly recommend you do AST ONLY in the fol lowing intervals e In a pre meal or fasting state more than 2 hours since the last meal e Two hours or more after taking insulin e Two hours or more after exercise DO NOT use AST if
19. ng blood glucose you need the following items 1 TysonBio AC100 meter 2 TysonBio AC100 test strip 3 Adjustable automatic lancing device 4 Sterile lancet Caution To reduce the chances of infection e Never share a lancing device and lancet with another person e Always use a new and sterile lancet Lancets are for single use only Always use a new test strip e Test strips are for single use only e Do not get lotion oil dirt or debris in or on the lancet and lancing device Preparing the Test Strip 1 Wash hands using soap and warm water Rinse and dry thoroughly 2 Pull out a test strip from the vial and re cap the vial immediately 3 Insert the test strip white side face up into the test port The meter will automatically turn on Fig 10 4 A beep will sound and a clockwise moving dotted lines will appear With the voice function on you will hear system rv checking 5 After system checking ok a flashing symbol will appear You can press AorW to select the meal indicator for marking the test as premeal Sor postmeal test S de fault premeal 6 Now you are ready to obtain a blood sample With the voice function on you will hear Please S apply blood sample Premeal or Postmeal Ee mg dl Obtaining a Blood Sample SAMPLE MAY BE OBTAINED FROM FINGER PALM or FOREARM For further instructions please see t
20. our TysonBio AC100 System is made up of several com ponents This booklet is designed to guide you through the operation of the system with detailed directions and pictures Your TysonBio AC100 System contains TysonBio AC100 Meter One vial of TysonBio AC100 Test Strips 10 strips One Lancing Device option Ten Lancets option One Control Solution One carrying case User s Manual Log book option Quick Reference Guide Note 25 50 test strips vial can be purchased individually About the TysonBio AC100 Meter 1 Display Shows blood glucose results and messages 2 M Button Press this button to set the year date time to view results and test average in memory or to turn the meter off 3 V Button Press this button to set alarm to enter control solution test mode or to decrease number move forward in meter setting 4 AButton Press this button to set voice guidance on off and select languages or to increase number move backward in meter setting 5 Test Port Insert the test strip here 6 Unit Switch Switch for mmol l or mg dL 7 Battery Cover Slide cover to install and replace bat teries 8 Label Contains meter serial number and customer service phone number 9 Reset Button Press this button to re set the system 10 Strip Eject Button Press this button to ejects the test strip 11 Data Port Connect interface cable to transfer data Front view Back view About the TysonBio AC100 Meter Displa
21. pecialists will be happy to assist you train you or even reaffirm your results Customer Service Hotline 1 800 948 3894 U S 24 hours a day 886 37 585998 or E Mail us at service tysonbio com website www tysonbio com When you call our customer service please have your TysonBio AC100 meter TysonBio AC100 test strip and all other system supplies available This will allow us to answer any of your questions with speed and efficiency CE 0537 B03R106908 01
22. rip is completely filled with your blood sample 3 After the test result appears if no further t tests are performed the meter will auto matically shut off after 3 minutes After AIN q finishing the test you can push the strip eject button to remove the used strip or use a tissue to remove test strip from the I i meter for proper disposal ONI Warning Always discharge the used test LT strip into suitable waste container Y7 z HI and LO Readings 1 TysonBio ACOO meter is designed to display test re sults range between 20 to 600 mg dL 1 1 to 33 3 mmol l If a HI message appears on the display your meter has detected that your blood glucose level is higher than 600 mg dL 33 3 mmol l It is suggested that you review your testing procedure and test again with a new test strip to confirm the result If the same result occurs consult your healthcare professional im mediately Fig 11 2 If a LO message appears on the display your meter has detected that your blood glucose level is lower than 20 mg dL 1 1 mmol l It is suggested that you re view your testing procedure and test again with a new test strip to confirm the result If the same result oc curs consult your healthcare professional immediately Fig 12 Ho LD Fig 11 Fig 12 Available Alternate Sites Testing Palm and Forearm TysonBio AC100 Blood Glucose Monitoring System provides you alternate s
23. se set reminder alarm The first reminder alarm will appear on the display Fig 5 Press A or W to seclect which alarm you want to set number 1 to 4 Press M to confirm Press A or W to select yes or no If no is chosen and M is pressed the meter goes to next reminder alarm setting If yes is chosen press M to confirm and the time will appear Fig 6 The number in the hour position will now flash Press A or Y to seclect hour Press M to set Fig 7 The minutes will now flash Press A or W to select the minutes Press M to set and meter will goes to next reminder alarm setting For the fourth reminder alarm press M will goes to HI alarm setting Fig 8 YES a l a 630 t a 530 i Fig 5 Fig 6 Fig 7 Fig 8 6 Repeat steps 3 to 5 to set the next three reminder alarms if needed 7 After finishing reminder alarm setting keep pressing and releasing W until HI alarm setting appear Note When the alarm is ringing press any one button to turn off or the alarm will turn off automatically after 30 sec Setting Up HI LO Alarm 1 After finishing the reminder alarm setting the HI alarm setting will appear Fig 9 With the voice function on you will hear Please set Hyperglycemic value 2 To change HI alarm setting press 4 or W until you reach your desired HI setting and then press M to set
24. ve 7 14 30 day average is calculated from the blood glucose results obtained during the last consecutive 7 14 30 day If there are not enough testing results for the calculation of 7 14 30 days pre meal and postmeal average pressing W will directly reach the end of the memory Exiting the Memory Mode 1 Press the M to turn off the meter at any time 2 Meter will shut down automatically after 3 minutes with no further action To Record Your Results We have provided a log book for your recording convenience To learn more about how to record your results please refer to the log book for further instructions Transfer Test Results to a Computer You can use your meter with TysonBio Link Health Man agement Software to transfer test results to your personal computer 1 Obtain the required software and cable For order information please call Customer Service or visit website of www tysonbio com N Install the software on a computer Follow the instructions provided with software to install the software 3 Get ready to transfer test results With meter turned off connect the interface cable to a serial port on your computer then connect the other end of interface cable to the data port located on the side of the meter The word PC will appear on the display indicating that the meter is in the communication mode tI ern 4 Transfer data Follow the instructions provided in the software to download
25. y e 086 00 i ADDA M o Ci e IA S 14 888 ti 1 Date 2 Time 3 Control Solution Test Appears when doing a control solution test and mark ing the result as a control solution test 4 Memory Symbol Indicates in memory mode 5 Units of Measurement Unit of mmol l or mg dL will appear with the test result 6 Battery Symbol Appears when the battery is low or must be replaced 7 Blood Drop Symbol Flashes when it is ready to apply sample to test strip 8 Warning Symbol Appears when result is out of the range of your setting reference value 9 Alarm Function Symbol Appears when the clock alarm is set 10 Test Strip Symbol Appears to tell you when the meter is ready for test 11 Day Average Symbol Shows the average value of test results 12 Test Result Area Display test results 13 Temperature Message Appears if your meter is out of operating temperature range 14 Meal Indicator Pre meal S and post meal amp About the TysonBio AC100 Test Strip The TysonBio AC100 test strip is used to perform the blood glucose test in conjunction with the TysonBio AC100 meter Each strip can be used only once The test strip consists of the following parts 1 Contact Bar This end of the test strip is inserted into the test port to activate the meter white side face up 2 Confirmation Window This is where you can confirm that enough blood has been appl