Home
Brochure
Contents
1. RTD and Thermocouple Modules Specialty modules are available for RTD and Thermocouple inputs Modules require a carrier base IC200CHSxxx IC200ALG620 IC200ALG630 Product Name VersaMax Analog Input Module 16 Bit RTD 4 Channel VersaMax Analog Input Module 16 Bit Thermocouple 7 Channel Input Range RTD types 25 100 and 1000 ohm platinum 10 50 and 100 ohm copper 100 and 120 ohm nickel 604 ohms nickel iron Thermocouple types J K T S R none used for mV inputs Number of Channels 4 7 Resolution 15 bits plus sign 15 bits plus sign Update Rate 60 Hz approximately 210 milliseconds per channel 50 Hz approximately 230 milliseconds per channel 60 Hz approximately 60 milliseconds per channel 50 Hz approximately 70 milliseconds per channel Accuracy at 25 C on voltage measurement 0 15 on resistance measurement on temperature measurement 0 15 on RTD temperature measurement on voltage measurement 0 2 on temperature measurement 0 15 5 V Backplane Current Consumption mA 125 maximum 125 maximum 3 3 V Backplane Current Consumption mA 125 maximum 125 maximum LED Indicators OK LED green indicates backplane power is present Amber indicates module fault OK LED green indicates backplane power is present Amber indicates module fault Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in
2. Dimensions WxHxD mm 36x90x60 Programming Software VersaPro 2 0 or greater Proficy Machine Edition Logic Developer Mounting 35 mm DIN Rail or Panel Mount Power Supply Voltage Range 12 24 VDC 236 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Portable Program Download Device PPDD The Portable Program Download Device enables the user to easily upload and download VersaMax Micro 23 28 con figuration and logic from to a USB Memory Stick Portable Program Download Device PPDD will support commercial memory stick devices using USB connection The purpose of the PPDD is to allow users to store and download their logic applications and configuration to GE VersaMax Micro 23 28 PLCs without the need of a PC The PPDD plugs into the 15 pin RS 485 port on the VersaMax Micro 23 28 CPU base power supply The RS 485 port provides the power for the PPDD VersaMax Micro 23 28 logic and configuration files can be zipped and easily emailed to remote locations for VersaMax Micro 23 28 downloads There are many advantages of the PPDD such as e No PC required to backup applications or download applications e No expensive travel to perform field upgrades just email the file to the remote location e Compatible with commercial off the shelf USB Memory Sticks e The PPDD can be panel mounted DIN rail mounted or hand held e Supports diagnostics to ensure that the
3. Points per Common 2 groups of 16 Isolated points Isolated points External Power Supply 10 2 30 VDC 12 24 VDC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal Load Current 0 5 A at 30 VDC maximum resistive 2 0 A inrush maximum for 100 ms 10 mA per point minimum 2 0 A for 5 265 VAC maximum resistive 2 0 A for 5 30 VDC maximum resistive 0 2 A for 31 125 VDC maximum resistive 10 mA per point minimum 2 0 A for 5 265 VAC maximum resistive 2 0 A for 5 30 VDC maximum resistive 0 2 A for 31 125 VDC maximum resistive 5V Backplane Current Consumption mA 90 maximum 245 maximum 490 maximum LED Indicators One LED per point shows individual point ON OFF state logic side FLD PWR LED indicates field power is present OK LED indicates backplane power is present One LED per point shows individual point ON OFF state logic side FLD PWR LED indicates field power is present OK LED indicates backplane power is present One LED per point shows individual point ON OFF state logic side FLD PWR LED indicates field power is present OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in
4. is present One LED per point shows individual point ON OFF status logic side OK LED indicates backplane power is present One LED per point shows individual point ON OFF status logic side OK LED indicates backplane power is present 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 191 VersaMax Discrete Output Modules IC200MDL730 C200MDL740 Discrete output modules send control signals to devices such as contactors indicator lamps and interposing relays that can also have two states Modules require a carrier base IC200CHSxxx C200MDL741 Product Name VersaMax Discrete Output Module 24 VDC Positive Logic 2 0A per point w ESCP 8 points VersaMax Discrete Output Module 24 VDC Positive Logic 0 5A per point 16 points VersaMax Discrete Output Module 24 VDC Positive Logic 0 5A per point w ESCP 16 points Output Voltage 17 5 30 VDC 24 VDC nominal 10 2 30 VDC 12 24 VDC nominal 18 30 VDC 24 VDC nominal Number of Points 8 16 16 Channel to Channel Isolation No No No
5. 2 0 5 5 MA 2 0 5 5 MA 5 mA minimum Off State Current 0 0 5 mA 0 0 5 mA 2 5 MA maximum External Power Supply 18 30 VDC 24 VDC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal Input Impedance 10 kOhms maximum 10 kOhms maximum 8 6 kOhms reactive at 60 Hz typical 10 32 kOhms reactive at 50 Hz typical Load Current 0 5 Amp at 30 VDC maximum resistive 2 0 Amps maximum for 100ms inrush 10mA per point minimum 2 0A for 5 to 265 VAC maximum resistive 2 0A for 5 to 30 VDC maximum resistive 0 2A for 31 to 125 VDC maximum resistive 10mA per point minimum 2 0A for 5 to 265 VAC maximum resistive 2 0A for 5 to 30 VDC maximum resistive 0 2A for 31 to 125 VDC maximum resistive 5V Backplane Current Consumption mA 70 maximum 270 maximum 300 maximum LED Indicators One LED per point shows individual point on off state logic side OK LED indicates backplane power is present One LED per point shows individual point on off state logic side OK LED indicates backplane power is present One LED per point shows individual point on off state logic side OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors
6. In addition the application needs Ethernet LAN to 6 inch color STN touch display Qty Part Number Description Controller I O and Display IC200UDR120 VersaMax Micro 20 point PLC 12 24VDC In 8 Relay Out 120 240VAC Power Supply IC200UEC208 VersaMax 8 point expansion unit 4 24VDC inputs 4 Relay Outputs and 24VDC Power Supply The VersaMax Micro 20 controller 24VDC user power supply can support the expansion module IC200UMM102 VersaMax Micro Motion 2 Axis Servo Module 120 240VAC Supply C200UEM001 VersaMax Micro 10 100Mbits Ethernet Module C754VSI06STD QuickPanel View Intermediate 6 inch STN Touch Servo Amplifier and Motor C800VMM10LBKSE25 VersaMotion 1000 Watt Low Inertia Servo Motor with brake Motor has keyway and oil seal C800VMA102 Servo Amplifier 1000 Watts 220VAC C800VMCB1030 Brake and Power Cable for 1000 Watt Servo Motor with brake 3 m 9 8 feet C800VMCE1030 Encoder Cable for 1000 Watt and greater 3 m 9 8 feet C800VMTBC005 1 0 terminal block and cable 0 5 meter IC800VMCS030 Communications cable from servo driver to PC 3 m 9 8 feet Programming Software for Control Display and Motion BC646MBLO01 Machine Edition Lite Development Suite with Proficy GlobalCare Complete Includes VersaMotion configuration tool View Development for QuickPanel and LD PLC Nano Micro Proficy GlobalCare with 15 months of free upgrades which is renewable on an annual basis 250 GE Intell
7. 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 183 VersaMax Discrete Mixed I O Modules Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single compact module Discrete input modules receive signals from input devices such as sensors push buttons and switches that can have two states on or off open or closed Discrete output modules send control signals to devices such as contactors indicator lamps and interposing relays that can also have two states Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single compact module Modules require a carrier base IC200CHSxxx IC200MDD847 IC200MDD848 IC200MDD849 Product Name VersaMax Discrete Mixed Modules 120 VAC Input Isolated 8 points Output Relay 2 0 A Isolated 8 points VersaMax Discrete Mixed Modules 120 VAC Input 8 points Output 120 VAC 0 5A Isolated 8 points VersaMax Discrete Mixed Modules 240 VAC Input 8 points Output Relay 2 0A Isolated 8 points Input Voltage 240 VAC 120 VAC 0 132 VAC 47 to 63 Hz 120 VAC nominal Output Voltage 0 125 VDC 5 24 125 VDC nominal 120 VAC 0 125 VDC 5 24 125 VDC nominal 0
8. 2 groups of 16 group of 16 2 groups of 16 External Power Supply 18 30 VDC 24 VDC nominal 4 75 to 5 25 VDC 5 VDC nominal for 5 VDC TTL mode 10 2 to 30 VDC 12 24 VDC nominal for 12 24 VDC mode 4 75 to 5 25 VDC 5 VDC nominal for 5 VDC TTL mode 10 2 to 30 VDC 12 24 VDC nominal for 12 24 VDC mode Load Current 0 5 A at 30 VDC maximum resistive 2 0 A inrush maximum for 100 ms 25 mA maximum for 5 VDC TTL mode 0 5 A at 30 VDC maximum 2 0 A inrush maximum for 100 ms for 12 24 VDC mode 25 mA maximum for 5 VDC TTL mode 0 5 A at 30 VDC maximum 2 0 Ainrush maximum for 100 ms for 12 24 VDC mode 5V Backplane Current Consumption mA 150 maximum 70 maximum 140 maximum LED Indicators One LED per point shows individual point ON OFF state logic side FLD PWR LED indicates field power is present OK LED indicates backplane power is present One LED per point shows individual point ON OFF state logic side FLD PWR LED indicates field power is present OK LED indicates backplane power is present One LED per point shows individual point ON OFF state logic side FLD PWR LED indicates field power is present OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the heigh
9. IC200TBX210 ool box Nano 10 Ethernet interface and software Includes IC200NDRO01 24 VDC In Relay Out 24 VDC powered requires an external 24 VDC Supply VersaMax SE IC200SETO01 with all software cables IC646MPH101 and manuals IC200TBX014 ool box Micro 14 and software Includes IC200UDRO01 24 VDC In Relay Out AC Power Supply with software manuals and cables IC646MPH101 IC200TBX114 ool box Micro 14 operator interface and software Includes IC200UDR001 24 VDC In Relay Out AC Power Supply VersaMax DataPanel DP45 with programming software and cables IC640VPS00 IC752DDZ000 IC200CBL555 IC200TBX214 ool box Micro 14 Ethernet interface and software Includes IC200UDRO01 24 VDC In Relay Out requires 120 VAC power VersaMax SE IC200SET001 with all software cables IC646MPH101 and manuals IC200TBX023 ool box Micro 23 and software Includes IC200UAL006 DC In Relay Out 2 analog In 1 analog out AC Power Supply with software manuals and cables IC646MPH101 IC200TBX123 ool box Micro 23 operator interface and software Includes IC200UAL006 24 VDC In Relay Out 2 Analog In 1 Analog out AC P S VersaMax DataPanel DP45 with programming software and cables IC640VPSO0 IC752DDZ000 IC200CBL555 IC200TBX223 ool box Micro 23 Ethernet interface and software Includes IC200UAL006 24 VDC In Relay Out requires 120 VAC Power VersaMax SE IC200SET001 with all software cables IC646MPH101 and manuals IC200TBX028 ool box
10. IC200UDRO10 28 point 16 24 VDC In 12 Relay Out 24 VDC Powered advantage is two serial ports Real Time clock and more data memory IC646MPH101 Logic Developer PDA Single License with Adapters With Logic Developer PDA you can monitor change data view diagnostics force ON OFF and configure machine setup saving you time and increasing productivity IC200ACC451 Simulator for VersaMax Micro 14 Micro 23 and Micro 28 8 Inputs IC690PWRO24 24 VDC 5 Amp Output Power and 120 230 VAC Input Power Power Supply IC200DTX650 Operator Interface with up to 200 stored messages 4x16 character LCD backlight display and 8 function keys Requires IC200CBL550 cable or equivalent Operates on external 24 VDC 80 mA Configuration for Micro 28 Example Application needing 22 24 VDC discrete inputs 16 outputs Ten Relay and Six 24 VDC 2 RTD inputs 1 Analog output using AC power Also requires Display with keypad Qty Part Number Description C200UDR005 28 point 16 24 VDC In 11 Relay Out 1 24 VDC Out 120 240 VAC Powered C200ACC403 Battery for Micro 23 and Micro 28 for data retention C200UEX014 14 point 8 24 VDC In 6 24 VDC Out 24 VDC Powered C200UEX736 4 RTD PT 100 Channels IN 2 Analog Channels OUT 0 to 10 VDC 4 to 20 mA 0 to 20 mA Out 120 240 VAC Powered BC646MPM101 Proficy Logic Developer PLC Nano Micro Programming Cable included and Proficy GlobalCare Complete Up
11. Load Current per Point 2 0 A per point 0 5 A per point 0 5 A per point Input and Output Response Time On Off ms 0 5 0 2 1 0 0 5 0 5 Protection Short circuit protection overcurrent protection each output No internal fuses each output Short circuit protection overcurrent protection free wheeling diodes each output Points per Common 1 group of 8 1 group of 16 1 group of 16 External Power Supply 18 30 VDC 24 VDC nominal 10 2 30 VDC 12 24 VDC nominal 18 30 VDC 24 VDC nominal 2 0 A at 30 VDC maximum resistive per point 8 0 A max per module Load Current 0 5 A at 30 VDC maximum resistive 2 0 A inrush maximum for 100 ms 0 5 A at 30 VDC maximum resistive 2 0 A inrush maximum for 100 ms 5V Backplane Current Consumption mA 50 maximum 45 maximum 75 maximum LED Indicators One LED per point shows individual point ON OFF state logic side FLD PWR LED indicates field power is present OK LED indicates backplane power is present One LED per point shows individual point ON OFF state logic side FLD PWR LED indicates field power is present OK LED indicates backplane power is present One LED per point shows individual point ON OFF state logic side FLD PWR LED indicates field power is present OK LED indicates backplane power is present 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the
12. Micro 28 and software Includes IC200UDRO05 24 VDC In Relay Out AC Power Supply with software manuals and cables IC646MPH101 IC200TBX128 ool box Micro 28 operator interface and software Includes IC200UDR005 24 VDC In Relay Out AC P S VersaMax DataPanel DP45 with programming software and cables IC640VPSO00 IC752DDZ000 IC200CBL555 IC200TBX228 ool box Micro 28 Ethernet interface and software Includes IC200UDRO05 24 VDC In Relay Out requires 120 VAC Power VersaMax SE IC200SETO01 with all software cables IC646MPH101 and manuals IC200TBX020 ool box Micro 20 and software Includes IC200UDD020 24VDC In 24VDC Out DC Power Supply IC200USB001 RS 232 option board with 2 0 10VDC analog in with Proficy software manuals and cables IC646MPM101 IC200TBX120 ool box Micro 20 and software Includes IC200UDR120 24VDC In Relay Out AC Power Supply IC200USB001 RS 232 option board with 2 0 10VDC analog in with Proficy software manuals and cables IC646MPM101 IC200TBX220 ool box Micro 20 operator interface and software Includes IC200UDD020 24VDC In 24VDC Out DC Power Supply IC200USB001 RS 232 option board with 2 0 10VDC analog in with VersaMax DataPanel DP45 with Proficy programming software and cables IC646MPM101 IC752DDZ000 IC200CBL555 IC200TBX320 ool box Micro 20 operator interface and software Includes IC200UDR120 24VDC In Relay Out AC Power Supply IC200USB001 RS 232 option board with 2 0 10VDC anal
13. Motion Control Method Motion commands can be controlled by Micro 20 40 64 or by Modbus Slave interface RS 232 IC200USB001 or RS 485 IC200USB002 or Ethernet IC200UEM001 Motion commands can be controlled by Micro 20 40 64 or by Modbus Slave interface RS 232 IC200USB001 or RS 485 IC200USB002 or Ethernet IC200UEM001 Power Voltage 24 VDC 120 240VAC Input Voltages line driver 5V 24 DC line driver 5V 24 DC Output Voltages 5VDC and 24VDC 5VDC and 24VDC Max Speed 500k Pulse s 500k Pulse s Number of Moves Stored on Unit 256 non volatile 256 non volatile Move Types 1 Absolute Increment method 2 Increment method 1 Absolute Increment method 2 Increment method Position Rollover Linear rotation Linear rotation Positioning Command Unit Pulse um inch degree Free form Pulse um inch degree Free form Speed Command Range 6 25 to 500k Pulse second 6 25 to 500k Pulse second Acceleration and Deceleration Liner Acc Dec S shaped Acc Dec Liner Acc Dec S shaped Acc Dec Dwell Time 0 to 65535 ms 1 ms unit 0 to 65535 ms 1 ms unit Acc Dec Rate 1 to 50 000 000 pulse s2 um s2 inch s2 degree s2 1 to 50 000 000 pulse s2 um s2 inch s2 degree s2 Backlash Correction 0 to 65 535 pulses um inch degree Free form 0 to 65 535 pulses um inch degree degree Free form Range Range 2 147 46
14. The VersaMotion family of servo motors offers high servo performance in a compact package The motors range from 100 W to 3 kW with continuous torque ratings from 0 3 Nm to 14 3 Nm All motors have metric mounting configurations and include a shaft key and oil seal For vertical axes or applications that need to hold position during power loss motors with 24 VDC holding brakes are available Motors are matched with the VersaMotion amplifiers IC800VMM10L IC800VMM10M IC800VMM20L IC800VMM20M IC800VMM30M Product Name VersaMotion VersaMotion VersaMotion VersaMotion VersaMotion 1000 Watt 1000 Watt 2000 Watt 2000 Watt 3000 Watt Rated Output kW 1 0 1 0 2 0 2 0 3 0 Rated Torque Nm 3 18 4 77 6 37 9 55 14 32 Maximum Torque Nm 9 54 14 32 19 11 28 66 42 96 Rated Speed RPM 3000 2000 3000 2000 2000 Maximum Speed RPM 5000 3000 5000 3000 3000 Rated Current Amps 73 5 6 113 11 0 16 1 Maximum Current Amps 21 9 24 9 33 9 33 0 48 3 Rotor Moment of Inertia Kg m2 x 10 74 2 65 9 14 4 45 15 88 55 Mechanical Time Constant msec 0 74 1 64 0 66 1 05 1 06 Torque Constant KT Nm A 0 44 0 85 0 53 0 87 0 89 Voltage Constant KE mV rpm 16 8 31 9 19 2 318 32 Armature Resistance Ohm 0 20 0 465 0 14 0 174 0 052 Armature Inductance mH 2 0 5 99 1 53 2 76 1 38 Electrical Time Constant msec 10 26 12 88 10 63 15 86 26 39 Maximum Radial Shaft Load Newton 490 490 490 490 1470 Maximum Thrust Shaft Load New
15. port 1 and optional port 2 DB 15 RS 485 or RJ 45 RS 232 or USB or RJ 45 Ethernet 10 100 Mbit Protocols Both Ports SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Ethernet SRTP Modbus TCP server and Tunneling Both Ports SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Ethernet SRTP Modbus TCP server and Tunneling Both Ports SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Ethernet SRTP Modbus TCP server and Tunneling Both Ports SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Ethernet SRTP Modbus TCP server and Tunneling Power Voltage 24 VDC 24 VDC 20 240 VAC 24 VDC Input Power Supply Rating 10 Watts 10 Watts 35 VA 10 Watts 24 VDC User Power for Sensors 435 mA 435 mA 435 mA 435 mA Input Device Voltage 24 VDC 24 VDC 24 VDC 24 VDC Maximum Type A and B Counters 4 Type A and 1 Type B 100Khz 32 bit 4 Type A and 1 Type B 100kKhz 32 bit 4 Type A and 1 Type B 100Khz 32 bit 4 Type A and 1 Type B 100kKhz 32 bit Output Control Voltage 24 VDC ESCP Self Healing 24 VDC Sink Relay Out Relay Out No External Fusing Required Relay Maximum Resistive Load Rating N A N A 2 Amps at 24 VDC 2 Amps at 24 VDC and 240 VAC and 240 VAC
16. speed pulse and direction commands from the controllers The VersaMotion servo drive is simple to use and main tain with the added diagnostics and removable terminal strips Amplifier setup can be accomplished using the VersaMotion software included with Proficy Machine Edition or using the convenient front panel keypad Key Features e Versatile analog or pulse command interface e Position Speed Torque modes e Dual control modes e Internal single axis position control e Electronic gearing e External JOG function e Speed Torque limit operation e Built in keypad display for setup and diagnostics e Motor settling time below 1 ms e Low speed stability and performance less than 0 5 error at 1 RPM e 10msec acceleration time from run ning without load 3000 RPM e High speed inertia corrections 16 levels of system stiffness and responsiveness www ge ip com Built in Functions e Point to Point single axis position control e Simple stand alone positioning function with 8 internal stored position settings e Move to Home function e Position Teaching capability e Incremental encoder feedback 2500 ppr e User definable Acceleration Deceleration with jerk limiting s curve e Feed step control function e Modbus Slave serial port RS 485 RS 422 for reading and writing parameters from Machine Edition Machine Edition VersaMotion Set up Features e Configuration Parameter Editor clear read wr
17. x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 189 VersaMax Discrete Input Modules Discrete input modules receive signals from input devices such as sensors pushbuttons and switches that can have two states on or off open or closed Modules require a carrier base IC200CHSxxx IC200MDL640 IC200MDL643 IC200MDL644 IC200MDL650 Product Name VersaMax Discrete Input VersaMax Discrete Input VersaMax Discrete Input VersaMax Discrete Input Module 24 VDC Module 5 12 VDC TTL Module 5 12 VDC TTL Module 24 VDC Positive Pos Neg Logic 16 points Pos Neg Logic 16 points Pos Neg Logic 32 points Logic 32 points Input Voltage 0 30 VDC 0 15 VDC 0 15 VDC 0 30 VDC Number of Points 16 16 32 32 Channel to Channel Isolation No No No No Input and Output Response Time On Off ms 0 5 0 25 0 25 0 5 Points per Common 2 groups of 8 2 groups of 8 4 groups of 8 2 groups of 8 On State Current 2 0 5 5 MA 1 45 mA minimum 1 45 mA minimum 2 0 5 5 mA Off State Current 0 0 5 mA 0 0 7 mA maximum 0 0 7 mA maximum 0 0 5 mA Input Impedance 10 kOhms maximum 2 4 kOhms at 1
18. x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 194 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Analog Input Modules Analog input modules receive signals from current and voltage input devices Modules require a carrier base IC200CHSxxx IC200ALG230 IC200ALG240 IC200ALG260 IC200ALG261 Product Name VersaMax Analog Input Module 12 Bit Voltage Current VersaMax Analog Input Module 16 Bit Voltage Current Isolated VersaMax Analog Input Module 12 Bit Voltage Current VersaMax Analog Input Module 15 Bit Differential Voltage 4 Channels 8 Channel 8 Channel 8 Channel Input Range 10 VDC or 0 10 VDC 10 VDC 4 20 mA 4 20mA 10 VDC 10 VDC or 0 10 VDC Number of Channels 4 8 8 8 Channel to channel isolated External Power Supply None Range 19 5 30 VDC including ripple None None Current consumption 100 mA maximum plus load currents Resolution Bipolar mode 2 5 mV Current mode 381 nA nominal Current mode 4 pA 8 counts Bipolar mode 0 3125 mV 8 counts Unipolar mode Voltage mode 381 uV nominal Bipolar mode 2 5 mV 1 counts 2 5 mV 8 counts 8 counts Unipolar mode 2 5 mV 8 counts Update Rate 0 4 ms Approximately 20 mS max 0 4 ms 7 5 ms 50 Hz filter frequency Approximately 1
19. 100 Watt to 750 Watt servo motor without brake 20 m 65 7 feet IC800VMCP1030 Power Cable for 1000 Watt servo motor without brake 3 m 9 8 feet IC800VMCP1050 Power Cable for 1000 Watt servo motor without brake 5 m 16 4 feet IC800VMCP1100 Power Cable for 1000 Watt servo motor without brake 10 m 32 8 feet IC800VMCP1200 Power Cable for 1000 Watt servo motor without brake 20 m 65 7 feet IC800VMCP2030 Power Cable for 2000 Watt servo motor without brake 3 m 9 8 feet IC800VMCP2050 Power Cable for 2000 Watt servo motor without brake 5 m 16 4 feet IC800VMCP2100 Power Cable for 2000 Watt servo motor without brake 10 m 32 8 feet IC800VMCP2200 Power Cable for 2000 Watt servo motor without brake 20 m 65 7 feet IC800VMCP3030 Power Cable for 3000 Watt servo motor without brake 3 m 9 8 feet IC800VMCP3050 Power Cable for 3000 Watt servo motor without brake 5 m 16 4 feet IC800VMCP3100 Power Cable for 3000 Watt servo motor without brake 10 m 32 8 feet IC800VMCP3200 Power Cable for 3000 Watt servo motor without brake 20 m 65 7 feet Brake and Motor Power Cables IC800VMCB030 Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake 3 m 9 8 feet IC800VMCB050 Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake 5 m 16 4 feet IC800VMCB100 Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake 10 m 32 8 feet IC80
20. 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 206 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Accessories IC200ACC001 Replacement Battery for VersaMax CPUs IC200ACCO003 EZ Program Store CPU RS 485 Port Update Device IC200ACC201 Expansion Terminator QTY 1 IC200ACC202 Expansion Terminator QTY 2 IC690ACC905 Encapsulated Thermistor Kit QTY 2 IC200ACC301 1 0 Filler Module IC200ACC302 1 0 Input Simulator IC200ACC303 1 0 Shorting Bar QTY 2 IC200ACC304 Cable Connector Kit QTY 2 for connector base IC200CHS003 I O Base IC200CHS011 CHS012 CHS014 CHSO15 and CHS1xx bases IC200ACC313 DIN rail clips Qty 2 to secure modules on DIN rail IC200TBM001 1 0 Auxiliary Terminal Strip 18 Internally Bussed Barrier Style IC200TBM002 1 0 Auxiliary Terminal Strip 18 Internally Bussed Box Style IC200TBM005 1 0 Auxiliary Terminal Strip 18 Internally Bussed Spring Clamp Style Cables for Connector Type Carrier IC200CBL105 Cable I O Non Shielded 2 Connectors 0 5M used with IC200CHS003 and IC200CHS011 012 015 IC200CBL110 Cable I O Non Shielded 2 Connectors 1 0M used with IC200CHS003 and IC200CHS011 012 015 IC200CBL120 Cable I O Non Shielded 2 Connectors 2 0M used with IC200CHS003 and IC200CHS011 012 015 IC200CBL230 Cable I O Non Shielded 1 Connector 3 0M used with IC200CHS
21. 150x90x76 Programming Software VersaPro 1 1 or greater VersaPro 1 1 or greater VersaPro 1 1 or greater Proficy Machine Edition VersaPro 1 1 or greater Proficy Machine Edition Proficy Machine Edition Proficy Machine Edition Logic Developer 5 0 Proficy Machine Edition Logic Developer Logic Developer Logic Developer Service Pack 3 Hotfix Logic Developer Portable Memory Module Support No No No No 218 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Micro 20 PLC The Micro 20 PLC is big on features expandable to 132 1 0 points to fast cycle times robust instruction set and generous memory to allow more flexible programming The optional sec ond port provides you with the option of an additional RS 232 port RS 485 USB or Ethernet The serial expansion ports come with two analog input channels A user friendly memory module is available to easily download changes to the controller without the need of a PC And it s all packaged in a sturdy modular design for easy access and long term durability This all in one PLC gives you everything you need to control a wide variety of applications IC200UDD020 IC200UDD220 IC200UDR120 IC200UDRO20 Product Name Micro 20 12 24 VDC In 8 24 VDC Source Out 0 7 amps with ESCP protection 24 VDC Powered Micro 20 12 24 VDC In 8 24 VDC Sink Out 24 VDC Powered Micro 20 12 24 VDC In 8 Relay Out
22. 4 95 in x 65 mm 2 6 in not including the height of the DIN Rail N A 253 7 mm 9 9 in x 126 mm 4 95 in x 73 mm 2 8 in not including the height of the DIN Rail Requires a IC200CBL1xxx cable 178 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax I O Interposing Bases VersaMax I O interposing disconnect bases enable the C200CHS003 to connect to a wide range of termination bases The Relay bases provide additional protection and higher amperage outputs The Disconnect bases enables the user to easily disconnect signals on a per point bases from the I O module IC200CHS112 IC200CHS211 IC200CHS212 Product Name 1 0 Interposing Relay Base replaceable relays fused 8 amps replaceable 16 points The relays on these interposing terminals are intended to be controlled with standard 24 VDC 0 5A VersaMax output modules IC200MDL740 and IC200MDL750 using IC200CHS003 base and connected by IC200CBL1xxx Expansion base 1 0 Interposing Relay Base replaceable relays fused 8 amps replaceable 16 points Field terminals are removable The relays on these interposing terminals are intended to be controlled with standard 24 VDC 0 5A VersaMax output modules IC200MDL740 and IC200MDL750 using IC200CHS003 base and connected by IC200CBL1xxx 1 0 Interposing Relay Base replaceable relays fused 8 amps replaceable 16 points Field terminals are removable The re
23. 5V 2 C200ALG262 VersaMax Analog Input Module 15 Bit Differential Current 8 Channel 10 5Vand115 3V 2 IC200ALG331 VersaMax Analog Output Module 14 Bit Voltage Current 1500 VAC Isolation 8 Channel 8 IC200CHS022 VersaMax Compact I O Carrier Local Box Clamp Connection Style 2 IC200ACC313 DIN rail clips Qty 2 to secure modules on DIN rail 1 BC646MBT001 Logic Developer PLC Standard Edition and View for QuickPanel with 15 mos of Proficy GlobalCare which is renewable on an annual basis 1 IC754VSIO6STD QuickPanel View Intermediate 6 inch STN Touch DC Total 1650 5 V and 765 3 V 3000 mA available for 5 V and 3 3 V Ethernet Remote Drop 175 5Vand 425 3 V 1 IC200ETM001 Bus Transmitter Expansion Module 1 IC200PWR002 24 VDC Power Supply with Expanded 3 3 V Logic side supply of 1 5 amps maximum Up to 1 0 amp can be allocated for 3 3 V usage 250 5 V and 250 3 V 2 IC200ALG630 VersaMax Analog Input Module 16 Bit Thermocouple 7 Channel 1 IC690ACC905 Encapsulated Thermistor Kit Qty 2 2 IC200CHS022 VersaMax Compact I O Carrier Local Box Clamp Connection Style i IC200ACC313 DIN rail clips Qty 2 to secure modules on DIN rail Total 2424 5 V and 790 3 V Required 4500 mA available for 5 V and 3 3 V Power Supply Booster required with extra Power Supply to meet power requirements Options to consider 1 IC646MPH101 Logic Developer PDA Single License with Adapters With Logic Developer PDA yo
24. Backlight Operating Temperature 0 C to 50 C 0 C to 50 C 0 C to 50 C 0 C to 50 C NEMA Rating NEMA 4 NEMA 4 NEMA 4 NEMA 4 Programming Software None required DataDesigner DataDesigner DataDesigner IC752DDZ000 IC752DDZ000 IC752DDZ000 234 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Micro 20 Micro 40 and Micro 64 Port 2 Communication Options The VersaMax Micro 20 Micro 40 and Micro 64 Port 2 is modular by design and enables the user to select a wide range of communications options The user can select RS 232 RS 485 Ethernet or USB The RS 232 and RS 485 also come with two analog input channels 0 to 10 VDC 10 bit Port 2 also supports Memory Module Board that enables the user to download logic and settings without a PC IC200UEM001 IC200USB001 1C200USB002 IC200UUB001 Product Name Ethernet module RS 232 option board with 2 0 10 VDC analog in RS 485 option board with 2 0 10 VDC analog in USB option board no analog option Micro Type Restrictions Micro 20 40 64 Support Only Micro 20 40 64 Support Only Micro 20 40 64 Support Only Micro 20 40 64 Support Only Connection Type 10 100Mbits port supporting RJ45 RS 232 RJ 45 RS 485 RJ 45 USB Slave Only version 2 0 connection Straight B type Protocol Supported SRTP and SNP SNP Master SNP X SNP SNP Master SNP X SNP SNP X Modbus TCP
25. Gear Ratio Gear Ratio N M where N 1 32767 M 1 32767 1 50 lt N M lt 200 Gear Ratio N M where N 1 32767 M 1 32767 1 50 lt N M lt 200 Electronic gear N M multiple N 1 32767 M 1 32767 1 50 lt N M lt 200 www ge ip com GE Intelligent Platforms Control Systems Solutions 245 VersaMax Micro amp Nano Servo Motor Part Number Sequence IC800VMM 30 M B k S E25 Feedback Rated Power E25 2500 ppr incremental encoder 01 100 Watts 02 200 Watts Shaft Seal 04 400 Watts S With seal 07 750 Watts 10 1000 Watts 20 2000 Watts 30 3000 Watts Key K With shaft key Brake N No brake B With brake except 100 Watt Motor Inertia L Low Inertia M Medium Inertia 1Kw 2Kw and 3Kw models only Example IC8B00VMM30MBKSE25 is a 3000 watt medium Inertia motor with 2500 ppr encoder brake keyway and shaft seal Motors Technical Data Insulation Class Class B Insulation Resistance gt 100M ohm 500 VDC Insulation Strength 1500 VAC 50Hz 60 seconds Vibration Grade um 15 Brake Power VDC 24 Operating Temperature C 0 40 Storage Temperature C 10 80 Humidity 20 90 RH non condensing Vibration 2 5G IP Rating IP65 except shaft and connector 246 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Motors The V
26. IC800VMCE050 Encoder Cable for 100 to 750 Watt 5 m 16 4 feet IC800VMCE100 Encoder Cable for 100 to 750 Watt 10 m 32 8 feet IC800VMCE200 Encoder Cable for 100 to 750 Watt 20 m 65 7 feet IC800VMCE1030 Encoder Cable for 1000 Watt and greater 3 m 9 8 feet IC800VMCE1050 Encoder Cable for 1000 watt and greater 5 m 16 4 feet IC800VMCE1100 Encoder Cable for 1000 watt and greater 10 m 32 8 feet IC800VMCE1200 Encoder Cable for 1000 watt and greater 20 m 65 7 feet 1 O Terminal Block IC800VMTBCO05 1 0 Terminal Block Breakout Board and 0 5 m 1 6 feet Cable External Braking Resistors IC800VMBRO40 40 Ohm 400 Watt External Braking Regeneration Resistor IC800VMBRO20 20 Ohm 1000 Watt External Braking Regeneration Resistor Communications and I O Interface Cables IC800VMCS030 Communications Cable from servo amplifier to PC 3 m 9 8 feet IC800VMCI010 Flying lead I O interface cable 1 meter IC800VMCI030 Flying lead I O interface cable 3 meter Software Configuration Tool IC646MPM101 Proficy Logic Developer PLC Nano Micro and VersaMotion Programming Cable No Upgrades included BC646MPM101 Proficy Logic Developer PLC Nano Micro and VersaMotion Programming Cable Includes 15 months of upgrades Examples of Typical Application using a VersaMax Micro Application 1000 Watt Low Inertia Motor with Brake and micro controller 14 24VDC inputs and 10 Relay outputs AC power supply
27. Maximum Number of PWM Pulse Outputs 4 65khz 32 bit 4 65khz 32 bit N A N A Dimensions WxHxD mm 190x90x76 190x90x76 190x90x76 190x90x76 Programming Software Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix Portable Memory Module Support Yes Yes Yes Yes www ge ip com GE Intelligent Platforms Control Systems Solutions 221 VersaMax Micro amp Nano Discrete Expansion Selection Guide Module 24 VDC 24 VDC 24 VDC Relay Relay Input 12 VDC 12 VDC 24 VDC 120 VAC Outputs Outputs Sink 120 VAC Outputs Outputs Model Power Inputs Outputs Inputs Input Source with ESCP Outputs Output 2 Amps 10 Amps IC200UEI08 24 VDC 8 Inputs IC200UEI016 24 VDC 16 Inputs IC200UEO008 24 VDC 8 Outputs IC200UEO016 24 VDC 16 Outputs IC200UEO108 24 VDC 8 Outputs IC200UEO116 24 VDC 16 Outputs IC200UERO08 24 VDC 8 Outputs IC200UERO16 24 VDC 16 Outputs IC200UECO08 24 VDC 4 Inputs 4 4 Inputs 4 Source Outputs Source Outputs IC200UEC108 24 VDC 4 Inputs 4 Sink 4 Inputs 4 Sink Outputs Outputs IC200UEC208 24 VDC 4 Inputs 4 4 Inputs 4 Relay Outputs Relay Outputs IC200UEX015 12 VDC 8 Inputs 6 8 Inputs 6 12 VDC O
28. Options to consider IC646MPH101 Logic Developer PDA Single License with Adapters With Logic Developer PDA you can monitor change data view diagnostics force ON OFF and configure machine setup saving you time and increasing productivity IC690PWRO24 24 VDC 5 Amp Output Power and 120 230 VAC Input Power Power Supply IC754VSIO6STD QuickPanel View Intermediate 6 inch STN Touch DC 100 5V IC200ACCO03 EZ Program Store CPU RS485 Port Update Device Configuration for Controller Ethernet connectivity 60 24 VOC inputs 20 Relay outputs 16 Analog Inputs 12 Thermocouples on a remote Ethernet drop 12 Isolated Analog Outputs and 24 VDC power supp ly Also requires Color TFT Operator Interface with Touch Screen Power Supply Current Required Qty Part Number Description 160 5 Vand 650 3 V C200CPUE05 VersaMax PLC CPU 128K Configurable User Memory 2 Ports RS 232 and RS 485 10 MBIT Ethernet Port Supports SRTP and EGD 2 C200PWR002 24 VDC Power Supply with Expanded 3 3 V Logic side supply of 1 5 amps maximum Up to 1 0 amp can be allocated for 3 3 V usage 1 C200PWB001 VersaMax Power Supply Booster Carrier Supplies power to all modules to the right of booster Requires power supply 100 5V 2 C200MDL650 VersaMax Discrete Input Module 24 VDC Positive Logic 32 points 980 5V 2 C200MDL940 VersaMax Discrete Output Module Relay 2 0 A per point Isolated Form A 16 points 400
29. PPDD will store verify controller Press PPDD download button The PPDD will stop the VersaMax Micro application and configuration the CPU and download verify file The CPU can be placed in onto the USB memory stick the Run mode via the key switch or cycling power gama _ a Email binary file TN i x 2 i i Ar Step 2 Step 3 Remove the memory stick from the PPDD and connect it Remote location takes the binary to your PC Copy the binary file from the memory stick to file that is in the email and stores your PC and email to remote location it on a USB memory stick Portable Program Download Device IC690ACC990 Portable Program Download Device Supports standard USB memory devices to store and load VersaMax Micro 23 28 PLC applications without the need of a PC 238 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Accessories IC200ACC402 Spare Removable Terminal Strips 10 per pack Micro 14 Micro 23 and Micro 28 and all expansion units IC200ACC403 Battery for Micro 23 and Micro 28 for data retention 5 2 months minimum 70 C and 32 4 months minimum 20 C IC200ACC404 Spare parts kit Two terminal strips and four plastic doors and four covers for Micro 14 Micro 23 and Micro 28 IC200ACC414 Long Term Battery for Micro 23 Micro 28 and Micro 64 19 months minimum 70 C and 121 months minimum 20 C IC200ACC415 RS 232 to RS 485 Converter requir
30. Proficy software manuals and cables IC646MPM101 IC200TBX264 ool box Micro 64 operator interface and software Includes IC200UDD064 24 VDC In 24 VDC Out DC Power Supply IC200USB001 RS 232 option board with 2 0 10 VDC analog in with VersaMax DataPanel DP45 with Proficy programming software and cables IC646MPM101 IC752DDZ000 IC200CBL555 IC200TBX364 ool box Micro 64 operator interface and software Includes IC200UDR164 24 VDC In Relay Out AC Power Supply IC200USB001 RS 232 option board with 2 0 10 VDC analog in with VersaMax DataPanel DP45 with Proficy Logic Developer programming software and cables IC646MPM101 IC752DDZ000 IC200CBL555 IC200TBX464 ool box Micro 64 stepper motor Power Cube amplifier and software Includes IC200UDD064 24 VDC In 24 VDC Out DC Power Supply IC200USB001 RS 232 option board with 2 0 10 VDC analog in stepping motor amplifier IC800PCUB00300 stepping motor MTR 1216 N D E 0 stepper cable CBL 12 MP 10 Power Cube Flying Lead interface cable IC800PCUBC02S030 with Proficy software manuals and cables IC646MPM101 IC200TBX564 ool box Micro 64 QuickPanel color touch screen and software Includes IC200UDR164 24 VDC In Relay Out AC Power Supply IC200UEM001 Ethernet option board QuickPanel Display IC754VSIO6STD with Proficy software manuals and cables BC646MBLO001 240 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Confi
31. VAC 120 VAC Output Control Voltage 24 VDC ESCP Relay Out Relay Out Relay Out 120 VAC Self Healing 2 at 10 Amps and No External 10 at 2 Amps Fusing Required Relay Maximum Resistive Load Rating N A 2 Amps at 24 VDC 2 Amps at 24 VDC 2 Amps at 24 VDC N A and 240 VAC and 240 VAC and 240 VAC 10 Amps at 24 VDC and 240 VAC Dimensions WxHxD mm 150x90x76 150x90x76 150x90x76 150x90x76 150x90x76 www ge ip com GE Intelligent Platforms Control Systems Solutions 227 VersaMax Micro amp Nano Discrete Expansion Units The VersaMax Micro s modular design provides you with remarkable flexibility in a compact control The versatile Micro PLC can support up to four Expansion Units of any mix of discrete or analog IC200UEX064 IC200UEX164 IC200UEX264 IC200UEX364 Product Name 64 point 40 24 VDC In 24 Relay Out 24 VDC Powered 64 point 40 24 VDC In 24 Relay Out 120 240 VAC Powered 64 point 40 24 VDC In 24 24 VDC Source Out 24 VDC Powered 64 point 40 24 VDC In 24 24 VDC Sink Out 24 VDC Powered Micro Type Restrictions Micro 20 40 64 Support Only Micro 20 40 64 Support Only Micro 20 40 64 Support Only Micro 20 40 64 Support Only Number of Discrete Inputs Outputs 40 In 24 Out 40 In 24 Out 40 In 24 Out 40 In 24 Out Power Voltage 24 VDC 120 240 VAC 24 VDC 24 VDC Input Power Supply Rating 10 Watts 35 VA 10 Watts 10 Watts 24 VDC User Power f
32. VersaMax Discrete Input Modules Discrete input modules receive signals from input devices such as sensors pushbuttons and switches that can have two states on or off open or closed Modules require a carrier base IC2O0CHSxxx IC200MDL144 IC200MDL240 IC200MDL241 Product Name VersaMax Discrete Input Module 240 VAC Isolated 4 points VersaMax Discrete Input Module 120 VAC Positive Logic 16 points VersaMax Discrete Input Module 240 VAC Positive Logic 16 points Input Voltage 0 264 VAC 0 132 VAC 0 264 VAC Number of Points 4 16 16 Channel to Channel Isolation Yes No No Input and Output Response Time On Off ms 1 cycle 2 cycles 1 cycle 2 cycles 1 cycle 2 cycles Points per Common 4 groups of 1 2 groups of 8 2 groups of 8 On State Current 7 MA minimum 5 mA minimum 4 mA minimum Off State Current 3 mA maximum 2 5 mA maximum 1 5 mA maximum Input Impedance 38 5 kOhms reactive at 60 Hz typical 46 3 kOhms reactive at 50 Hz typical 8 6 kOhms reactive at 60 Hz typical 10 32 kOhms reactive at 50 Hz typical 38 5 kOhms reactive at 60 Hz typical 46 3 kOhms reactive at 50 Hz typical 5V Backplane Current Consumption mA 30 maximum 110 maximum 110 maximum LED Indicators One LED per point shows individual point ON OFF status OK LED indicates backplane power is present One LED per point shows individual poin
33. a IC200CBL1xxx cable 253 7 mm 9 9 in x 126 mm 4 95 in x 73 mm 2 8 in not including the height of the DIN Rail N A www ge ip com GE Intelligent Platforms Control Systems Solutions 179 VersaMax Power Supplies VersaMax Power Supply modules snap onto any VersaMax CPU or Network Interface Unit or onto a power supply booster carrier Each power supply can be used as the main power source for modules in the I O station or as a source of supplemental power for larger 1 0 applications IC200PWROO1 IC200PWROO2 IC200PWR101 IC200PWR102 Product Name 24 VDC 24 VDC Power Supply 120 240 VAC 120 240 VAC Power Supply Power Supply with Expanded 3 3 V Power Supply with Expanded 3 3 VDC Input Voltage 24 VDC 24 VDC 120 240 VAC 120 240 VAC Output Voltage 5 VDC 3 3 VDC 5 VDC 3 3 VDC 5 VDC 3 3 VDC 5 VDC 3 3 VDC Extended Power No Yes No Yes Input Power 11W 11W 27 VA 27 VA Holdup Time 10 ms 10 ms 20 ms 20 ms Inrush Current 20 A 24 VDC 20 A 24 VDC N A N A 25 A 30 VDC 25 A 30 VDC Protection Short circuit overload Short circuit overload Short circuit overload Short circuit overload reverse polarity reverse polarity Total Output Current 1 5 A maximum 1 5 A maximum 1 5 A maximum 1 5 A maximum 3 3V Output Current 0 25 A maximum 1 0 A maximum 0 25 A maximum 1 0 A maximum 5V Output Current 1 5 A minus the 3 3V 1 5 A minus the 3 3V 1 5 A minus the 3 3V 1 5 A minus the 3 3V current used maximum curren
34. analog in 3 C800PCUB00300 Stepping Motor Power Amplifier 12 48 VDC 4 Amp 3 IC800CUBDB15ADP Motor Cube or Power Cube DB15 to screw terminal connector adaptor 3 MTR 1221 N D E O Stepping Motor Nema23 Series Wdg Holding Torque 124 oz in 0 87 Nano meters 3 CBL 12 MP 10 Power Cable MTR 1216 1221 or 1231 Stepping Motor 10 Ft 3 C800PCUBC10S050 Power Cube Flying Lead I O Interface Cable 1000 Steps Rev amp Power Save Enabled 5 Meters IC754VSIO6STD QuickPanel View Intermediate 6 inch STN Touch DC BC646MBLO01 Machine Edition Lite Development Suite with Proficy GlobalCare Complete Includes View Development for QuickPanel and LD PLC Nano Micro with 15 mos of Proficy GlobalCare which is renewable on an annual basis C200CBL500 Programming cable RJ 45 to DB 9 pin RS 232 3 Meters Options to consider C646MPH101 Logic Developer PDA Single License with Adapters With Logic Developer PDA you can monitor change data view diagnostics force ON OFF and configure machine setup saving you time and increasing productivity C200UMB001 Flash Memory Board for program download and compatible with Micro 64 128Kbytes C690PWR124 24 VDC 10 Amp Output Power and 120 230 VAC Input Power Power Supply 242 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano VersaMotion VersaMotion is a family of servo motors and amplifiers The VersaMotion amplifier supports high
35. base IC2O0CHSxxx IC200MDL632 C200MDL635 IC200MDL636 Product Name VersaMax Discrete Input Module 125 VDC Pos Neg Logic Isolated 16 points VersaMax Discrete Input Module 48 VDC Pos Neg Logic 2 Groups of 8 16 points VersaMax Discrete Input Module 48 VDC Pos Neg Logic 4 Groups of 8 32 points Input Voltage 0 150 VDC 125 VDC nominal 0 60 VDC 48 VDC nominal 0 60 VDC 48 VDC nominal Number of Points 16 isolated inputs 16 inputs 2 groups of 8 32 4 groups of 8 Channel to Channel Isolation Yes No No Input and Output Response Time On Off ms 0 5 maximum 0 5 maximum 0 5 maximum Points per Common 16 groups of 1 2 groups of 8 4 groups of 8 On State Current 1 0 mA minimum 1 0 mA minimum 1 0 mA minimum Off State Current 0 to 0 1 mA maximum 0 to 0 4 mA maximum 0 to 0 4 mA maximum Input Impedance 74 K Ohm typical at 125 VDC 28 K Ohm typical 28 K Ohm typical 5V Backplane Current Consumption mA 80 maximum 70 maximum 140 maximum LED Indicators One LED per point shows individual point ON OFF status OK LED indicates backplane power is present One LED per point shows individual point ON OFF status OK LED indicates backplane power is present One LED per point shows individual point ON OFF status OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in
36. mating connectors Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 192 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Discrete Output Modules IC200MDL742 C200MDL743 Discrete output modules send control signals to devices such as contactors indicator lamps and interposing relays that can also have two states Modules require a carrier base IC200CHSxxx IC200MDL744 Product Name VersaMax Discrete Output Module 24 VDC Positive Logic 0 5A with ESCP 32 points VersaMax Discrete Output Module 5 12 24 VDC Negative Logic 0 5 A per point 1 group of 16 16 points VersaMax Discrete Output Module 5 12 24 VDC Negative Logic 0 5 A per point 2 groups of 16 32 points Output Voltage 18 30 VDC 24 VDC nominal 5 12 24 VDC 5 12 24 VDC Number of Points 32 16 1 group of 16 32 2 groups of 16 Channel to Channel Isolation No No No Load Current per Point 0 5 A per point 0 5 A per point 0 5 A per point Input and Output Response Time On Off ms 0 5 0 5 0 2 1 0 0 2 1 0 Protection Short circuit protection overcurrent protection free wheeling diodes each output No internal fuse No internal fuse Points per Common
37. not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 200 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Specialty Modules Modules require a carrier base IC200CHSxxx C200MDD841 Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single compact module Discrete input modules receive signals from input devices such as sensors pushbuttons and switches that can have two states on or off open or closed Discrete output modules send control signals to devices such as contactors indicator lamps and interposing relays that can also have two states Discrete mixed modules pro vide maximum flexibility by combining inputs and outputs in a single compact module Product Name VersaMax Discrete Mixed Modules 24VDC Pos Logic Input 20 Output 12 HSC PWM or Pulse Train Input Voltage 24 VDC Output Voltage 24 VDC Number of Points 20 in 12 out 4 configurable Channel to Channel Isolation No Inrush Current 2 0 A maximum for 100 ms Input and Output Response Time On Off ms 7 and 0 5 Protection No internal fuses On State Current 3 0 8 0 mA Off State Current 0 0 5 mA External Power Supply 24 VDC nominal 18 30 VDC Input Impedance 9 6 kOhms maximum Load Cur
38. of Discrete 24 In 16 Out 24 In 16 Out 24 In 16 Out 24 In 16 Out 24 In 16 Out Inputs Outputs Supports 4 Expansion Units Supports 4 Expansion Units Supports 4 Expansion Units Supports 4 Expansion Units Supports 4 Expansion Units Number of Analog Supports up to 4 analog Supports up to 4 analog Supports up to 4 analog Supports up to 4 analog Supports up to 4 analog Inputs Outputs expansion units expansion units expansion units expansion units expansion units 16 analog in 8 analog out 16 analog in 8 analog out 16 analog in 8 analog out 16 analog in 8 analog out 16 analog in 8 analog out Physical I O Maximum 152 152 152 152 152 User Program Logic Memory Words 24K 24K 24K 24K 24K Registers Words 32K 32K 32K 32K 32K Analog Pots for Data Adjustment No No No No No Serial Port RJ 45 RS 232 port 1 RJ 45 RS 232 port 1 RJ 45 RS 232 port 1 RJ 45 RS 232 port 1 RJ 45 RS 232 port 1 Connector Type and optional port 2 DB 15 and optional port 2 DB 15 and optional port 2 DB 15 and optional port 2 DB 15 and optional port 2 DB 15 RS 485 or RJ 45 RS 232 RS 485 or RJ 45 RS 232 RS 485 or RJ 45 RS 232 RS 485 or RJ 45 RS 232 RS 485 or RJ 45 RS 232 or USB or RJ 45 or USB or RJ 45 or USB or RJ 45 or USB or RJ 45 or USB or RJ 45 Ethernet 10 100Mbit Ethernet 10 100Mbit Ethernet 10 100Mbit Ethernet 10 100Mbit Ethernet 10 100Mbit Protocols Both Ports SNP SNP X Both Ports SNP SNP X B
39. position data from encoder differential B Channel position data from encoder differential Z Channel position data from encoder differential Positioning finish signal from servo driver COIN Home limit switch input Common for Digital Inputs Jog Forward Jog Reverse Feedrate Override Estop Drive OK Ready Outputs Clockwise Pulse Pulse differential Counter Clockwise Pulse Direction differential Portable Memory Module Support Yes Yes 1 0 Bus Data Assignement Module requires 8 words in and 8 words out The module appears as two expansion units A maximum of two motion modules allowed per controller If one motion module is in system 2 additional discrete or analog expansions can be used Module requires 8 words in and 8 words out The module appears as two expansion units A maximum of two motion modules allowed per controller If one motion module is in system 2 additional discrete or analog expansions can be used Dimensions WxHxD mm 150x90x76 150x90x76 www ge ip com GE Intelligent Platforms Control Systems Solutions 233 VersaMax Micro amp Nano IC200DTX200 IC200DTX450 IC200DTX850 IC200DTX650 DataPanels Operator Interfaces GE VersaMax DataPanels are ideal for a broad range of applications ranging from simple timer counter register access to full text message display with numeric keypad All VersaMax DataPanels are preprogrammed to connect quickly to a VersaMax Mi
40. present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 198 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Analog Mixed Modules Analog mixed modules provide maximum flexibility by combining inputs and outputs in a single compact module Modules require a carrier base IC200CHSxxx IC200ALG430 IC200ALG431 IC200ALG432 Product Name VersaMax Analog Mixed Module 12 Bit Input Current 4 Channel Output Current 2 Channel VersaMax Analog Mixed Module 12 Bit 0 10V Input 4 Channel Output 0 10V 2 Channel VersaMax Analog Mixed Module 12 Bit 10V Input 4 Channel Output 10V 2 Channel Input Range 4 20 mA 0 10 VDC 10 to 10 VDC Output Range 4 20 mA 0 10 VDC 10 to 10 VDC External Power Supply Range 18 30 VDC including ripple Current consumption 125 mA m
41. station 8 per NIU station Redundancy Full media and hardware redundancy supported N A 5V Backplane Current Consumption mA 250 250 3 3V Backplane Current Consumption mA 10 10 Dimensions W x H x D 133 4 mm 5 25 in x 85 9 mm 3 38 in not including the height of power supply 133 4 mm 5 25 in x 85 9 mm 3 38 in not including the height of power supply 204 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Network Interface Modules Network Interface Modules allow a VersaMax PLC to operate as a master or slave on a net work Modules currently available support DeviceNet master or slave communications and Profibus DP slave communications An AS i master communications is also available IC200BEM002 IC200BEM103 IC200BEM104 IC200CHS006 Product Name PLC Network Communications PLC Network Communications PLC Network Communications VersaMax I O Local Profibus DP Slave DeviceNet Master AS i Master Communications Carrier Requires IC200CHS006 Requires IC200CHS006 Requires IC200CHS006 Supports IC200BEMxxx Communications Carrier Communications Carrier Communications Carrier Modules Number of Stations 32 without repeaters N A N A N A up to 125 with repeaters 1 0 Data 384 Bytes maximum up to Up to 128 bytes of inputs 4 input bits and 4 output N A 244 bytes of inputs or and 128 bytes of outputs bits per slave 244 bytes of outputs Network Da
42. with an all in one construction that saves panel space Installation is a breeze simply snap it onto a DIN rail or mount it on a panel Because it gives you more capabilities in a smaller less expensive package the Nano PLC is ideal for high volume applications that require low cost compact size and fast processor speeds The Nano decreases your life cycle costs as well with easy installation and long term reliability IC200NAL110 IC200NAL211 IC200NDD010 IC200NDD101 IC200NDRO01 IC200NDRO10 Product Name 10 point 6 10 point 6 10 point 6 10 point 6 10 point 6 10 point 6 12 VDC In 1 24 VDC In 1 12 VDC In 24 VDC In 24 VDC In 12 VDC In Analog Voltage Analog Voltage 4 12 VDC Out 4 24 VDC Out 4 Relay Out 4 Relay Out In 4 Relay In 4 Relay 12 VDC Powered 24 VDC Powered 24 VDC Powered 12 VDC Powered Out 12 VDC Out 24 VDC Powered Powered Number of Discrete Inputs Outputs 6 In 4 Out 6 In 4 Out 6 In 4 Out 6 In 4 Out 6In 4 Out 6 In 4 Out Non Expandable Non Expandable Non Expandable Non Expandable Non Expandable Non Expandable Number of Analog Inputs Outputs 1In 1In N A N A N A N A Physical I O Maximum 10 10 10 10 10 10 User Program Logic Memory Words 2K 2K 2K 2K 2K 2K Registers Words 256 256 256 256 256 256 Analog Pots for Data Adjustment Yes 2 Yes 2 Yes 2 Yes 2 Yes 2 Yes 2 Serial Port Connector Type RJ 45 RS 232 RJ 45 RS 232 RJ 45 RS 232 RJ
43. x 50 mm 1 956 in not including the height of the carrier or the mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 197 VersaMax Analog Output Modules IC200ALG325 IC200ALG326 IC200ALG327 Analog output modules provide voltage or current signals to analog output devices Modules require a carrier base IC200CHSxxx IC200ALG328 IC200ALG331 Product Name VersaMax Analog Output Module 13 Bit 10 VDC VersaMax Analog Output Module 13 Bit Current VersaMax Analog Output Module 13 Bit 10 VDC VersaMax Analog Output Module 13 Bit 0 20 mA VersaMax Analog Output Module 14 Bit Voltage or 0 to 10 VDC Voltage 8 Channel or 0 to 10 VDC Voltage 4 20 mA Current Current 1500 VAC Isolation 8 Channel 12 Channel 12 Channel 4 Channel Output Range 10 VDC or 0 to 10 VDC 4to 20 mA 10 VDC or 0 to 10 VDC 4 to 20 mA default 10 VDC 4 20 mA O to 20 mA configured with jumper Number of Channels 8 8 12 12 single ended one group 4 External Power Supply Range 18 30 VDC including ripple Current consumption 102 mA maximum Range 18 30 VDC including ripple 2A inrush maximum 100 mA maximum no load 185 mA maximum all 8 outputs at full scale Range 18 30 VDC including ripple Current consumption 112 mA maximum Range 18 30 VDC including ripple Current consumption 100 mA maximum no load Range 19 5 30 VDC including ripple Current consu
44. 0 0 3 5khz 16 bit 3 5khz 16 bit 0 0 Dimensions WxHxD mm 75x80x47 75x80x47 75x80x47 75x80x47 75x80x47 75x80x47 Operating Temperature O C to 55 C 0 C to 55 C 0 C to 55 C 0 C to 55 C 0 C to 55 C 0 C to 55 C Programming Software VersaPro 2 0 or greater Proficy Machine Edition Logic Developer VersaPro 2 0 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer Portable Memory Module Support No No No No No No www ge ip com GE Intelligent Platforms Control Systems Solutions 213 VersaMax Micro amp Nano Micro 14 PLCs The Micro 14 PLC is big on features from up to 14 I O built in expandable to 126 1 0 points to fast cycle times robust instruction set and generous memory to allow more flexible pro gramming And it s all packaged in a sturdy modular design for easy access and long term durability This all in one PLC gives you everything you need to control a wide variety of applications IC200UAA003 IC200UAR014 IC200UDD104 1C200UDD112 Product Name 14 point 8 120 VAC In 14 point 8 120 VAC In 14 point 8 24 VDC In 14 point 8 12 VDC In 6 120 VAC Out 6
45. 0 A for one cycle 20 ms maximum inrush 10 mA per point minimum 2 0 A for 5 265 VAC maximum resistive 2 0 A for 5 30 VDC maximum resistive 0 2 A for 31 125 VDC maximum resistive 5V Backplane Current Consumption mA 300 maximum 125 maximum 300 maximum LED Indicators One LED per point shows individual point on off state logic side OK LED indicates backplane power is present One LED per point shows individual point on off state logic side OK LED indicates backplane power is present One LED per point shows individual point on off state logic side OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50mm 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of 1 956 in not including the height of the carrier or the mating connectors the carrier or the mating connectors 184 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Discrete Mixed I O Modules Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single compact module Discrete input modules receive signals from input devices such as sensors push buttons and switches that can have two states on or off open or closed Discrete output modules send control signals to devi
46. 003 and IC200CHS011 012 015 Cables to Connect Rack to Rack Expansion IC200CBL600 Rack Expansion Cable Shielded Single Ended 1M to One Expansion Receiver Module IC200ERMOOx IC200CBL601 Rack Expansion Cable Shielded 2 Connectors 1M Supports Multidrop to Multiple Expansion Receiver Modules IC200ERMOOx IC200CBL602 Rack Expansion Cable Shielded 2 Connectors 2M Supports Multidrop to Multiple Expansion Receiver Modules IC200ERMOOx IC200ACC304 Cable Connector Kit QTY 2 for connector base IC200CHS003 I O Base IC200CHS011 CHS012 CHS014 CHSO15 and CHS1xx bases Starter Kits IC200PKG001 PLC Starter Kit CPU001 Contains CPU001 PWR101 MDD845 CHS002 ACC302 CBLO01 GFK 1503 GFK 1504 641VPS300 Infolink included coffee mug and plastic carry case Does not include 24 VDC power supply for inputs IC200PKG010 PLC Starter Kit CPUEOS Contains CPUE05 PWR101 MDD845 CHS002 ACC302 CBLO01 GFK 1503 GFK 1504 Machine Edition Infolink included coffee mug and plastic carry case Does not include 24 VDC power supply for inputs IC200PKG101 1 0 Starter Kit GENIUS Contains GBI001 PWR101 MDD845 CHS002 ACC302 CBLO01 GFK 1535 GFK 1504 690CDRO02 Infolink coffee mug and plastic carry case Does not include 24 VDC power supply for inputs IC200PKG102 1 0 Starter Kit Profibus DP Contains PBI001 PWR101 MDD845 CHS002 ACC302 CBLO01 GFK 1534 GFK 1504 690CDRO02 Infolink coffee mug and plastic carry ca
47. 0VMCB200 Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake 20 m 65 7 feet IC800VMCB1030 Brake and Motor Power Cable for 1000 Watt servo motor with brake 3 m 9 8 feet IC800VMCB1050 Brake and Motor Power Cable for 1000 Watt servo motor with brake 5 m 16 4 feet IC800VMCB1100 Brake and Motor Power Cable for 1000 Watt servo motor with brake 10 m 32 8 feet IC800VMCB1200 Brake and Motor Power Cable for 1000 Watt servo motor with brake 20 m 65 7 feet IC800VMCB2030 Brake and Motor Power Cable for 2000 Watt servo motor with brake 3 m 9 8 feet IC800VMCB2050 Brake and Motor Power Cable for 2000 Watt servo motor with brake 5 m 16 4 feet IC800VMCB2100 Brake and Motor Power Cable for 2000 Watt servo motor with brake 10 m 32 8 feet IC800VMCB2200 Brake and Motor Power Cable for 2000 Watt servo motor with brake 20 m 65 7 feet IC800VMCB3030 Brake and Motor Power Cable for 3000 Watt servo motor with brake 3 m 9 8 feet IC800VMCB3050 Brake and Motor Power Cable for 3000 Watt servo motor with brake 5 m 16 4 feet IC800VMCB3100 Brake and Motor Power Cable for 3000 Watt servo motor with brake 10 m 32 8 feet IC800VMCB3200 Brake and Motor Power Cable for 3000 Watt servo motor with brake 20 m 65 7 feet www ge ip com GE Intelligent Platforms Control Systems Solutions 249 VersaMax Micro amp Nano Encoder Cables IC800VMCE030 Encoder Cable for 100 to 750 Watt 3 m 9 8 feet
48. 1 24 VDC 12 Relay Out 12 VDC 11 Relay Out 1 24 11 Relay Out 1 24 12 VDC Powered Out 120 240 VAC Powered VDC Out 12 24 VDC VDC Out 24 VDC Powered Powered Powered Number of Discrete Inputs Outputs 16 In 12 Out 16 In 12 Out 16 In 12 Out 16 In 12 Out 16 In 12 Out Supports 4 Supports 4 Supports 4 Supports 4 Supports 4 Expansion Units Expansion Units Expansion Units Expansion Units Expansion Units Number of Analog Inputs Outputs Supports up to 4 analog Supports up to 4 analog Supports up to 4 analog Supports up to 4 analog Supports up to 4 analog expansion units expansion units expansion units expansion units expansion units 16 analog in 16 analog in 16 analog in 16 analog in 16 analog in 8 analog out 8 analog out 8 analog out 8 analog out 8 analog out Physical I O Maximum 140 140 140 140 140 User Program Logic Memory Words 9K 9K 9K 9K 9K Registers Words 2K 2K 2K 2K 2K Analog Pots for Data Adjustment Yes 2 Yes 2 Yes 2 Yes 2 Yes 2 Serial Port Connector Type RJ 45 RS 232 port 1 and RJ 45 RS 232 port Land RJ 45 RS 232 port Land RJ 45 RS 232 port 1 and RJ 45 RS 232 port 1 and DB 15 RS 485 on port 2 DB 15 RS 485 on port 2 DB 15 RS 485 on port 2 DB 15 RS 485 on port 2 DB 15 RS 485 on port 2 Protocols Port 1 SNP SNP X Port 1 SNP SNP X Port 1 SNP SNP X Port 1 SNP SNP X Port 1 SNP SNP X Breakless Port 2 Breakless Port 2 Breakless Port
49. 2 Breakless Port 2 Breakless Port 2 SNP SNP X Breakless SNP SNP X Breakless SNP SNP X Breakless SNP SNP X Breakless SNP SNP X Breakless RTU Master and Slave RTU Master and Slave RTU Master and Slave RTU Master and Slave RTU Master and Slave 2 and 4 wire RTU Slave 2 and 4 wire RTU Slave 2 and 4 wire RTU Slave 2 and 4 wire RTU Slave 2 and 4 wire RTU Slave SNP Master Serial Read SNP Master Serial Read SNP Master Serial Read SNP Master Serial Read SNP Master Serial Read and Write and Write and Write and Write and Write Power Voltage 12 VDC 120 240 VAC 12 VDC 12 24 VDC 24 VDC Input Power Supply Rating 8 Watts 26 VA 8 Watts 8 Watts 8 Watts 24 VDC User Power for Sensors 200 mA 200 mA 200 mA 140 mA 200 mA Input Device Voltage 12 VDC 24 VDC 12 VDC 24 VDC 24 VDC Maximum Type A and B Counters 4 Type A and 1 Type B 4 Type A and 1 Type B 4 Type A and 1 Type B 4 Type Aand 1 TypeB 4 Type A and 1 Type B 10Khz 16 bit 10Khz 16 bit 10Khz 16 bit 10Khz 16 bit 10Khz 16 bit Output Control Voltage 12 VDC Relay Out Relay Out Relay Out Relay Out Relay Maximum Resistive Load Rating N A 2 Amps at 24 VDC 2 Amps at 24 VDC 2 Amps at 24 VDC 2 Amps at 24 VDC and 240 VAC and 240 VAC and 240 VAC and 240 VAC Maximum Number of PWM Pulse Outputs 4 5Khz 32 bit 1 5Khz 16 bit 1 5Khz 16 bit 1 5Khz 16 bit 1 5Khz 16 bit Dimensions WxHxD mm 150x90x76 150x90x76 150x90x76 150x90x76
50. 2 0 amps 120 240VAC Powered Micro 20 12 24 VDC In 8 Relay Out 2 0 amps 24VDC Powered Number of Discrete Inputs Outputs 12 In 8 Out Supports 4 Expansion Units 12 In 8 Out Supports 4 Expansion Units 12 In 8 Out Supports 4 Expansion Units 12 In 8 Out Supports 4 Expansion Units Number of Analog Supports up to 4 analog Supports up to 4 analog Supports up to 4 analo Supports up to 4 analog Inputs Outputs expansion units expansion units expansion units expansion units 16 analog in 8 analog out 16 analog in 8 analog out 16 analog in 8 analog out 16 analog in 8 analog out Physical I O Maximum 132 132 132 132 User Program Logic 24K 24K 24K 24K Memory Words Registers Words 32K 32K 32K 32K Analog Pots for No No No No Data Adjustment Serial Port Connector Type RJ 45 RS 232 port 1 and optional port 2 DB 15 RS 485 or RJ 45 RS 232 or USB or RJ 45 Ethernet 10 100Mbit RJ 45 RS 232 port 1 and optional port 2 DB 15 RS 485 or RJ 45 RS 232 or USB or RJ 45 Ethernet 10 100Mbit RJ 45 RS 232 port 1 and optional port 2 DB 15 RS 485 or RJ 45 RS 232 or USB or RJ 45 Ethernet 10 100Mbit RJ 45 RS 232 port 1 and optional port 2 DB 15 RS 485 or RJ 45 RS 232 or USB or RJ 45 Ethernet 10 100Mbit Protocols Both Ports SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Ethernet SR
51. 2 VDC typical 2 4 kOhms at 12 VDC typical 10 kOhms maximum 5V Backplane Current Consumption mA 25 maximum 70 maximum 140 maximum 50 maximum LED Indicators One LED per point shows One LED per point shows One LED per point shows One LED per point shows individual point ON OFF status individual point ON OFF status individual point ON OFF status individual point ON OFF status OK LED indicates backplane OK LED indicates backplane OK LED indicates backplane OK LED indicates backplane power is present power is present power is present power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in 110 mm 4 3 in x 66 8 mm 2 63 in 110 mm 4 3 in x 66 8 mm 2 63 in 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including x 50 mm 1 956 in not including x 50 mm 1 956 in not including x 50 mm 1 956 in not including the height of the carrier or the the height of the carrier or the the height of the carrier or the the height of the carrier or the mating connectors mating connectors mating connectors mating connectors 190 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Discrete Output Modules IC200MDL329 C200MDL330 Discrete output modules send control signals to devices such as contactors indicator lamps and interposing relays that can also have two states Modules require a carrier base IC200CHSxxx IC200MDL331 Product Name VersaMax Discrete Output Module 120 VAC 0
52. 200 mA 200 mA Input Device Voltage 12 VDC 24 VDC 24 VDC Maximum Type A and B Counters 4 Type A and 1 Type B 10Khz 16 bit 4 Type A and 1 Type B 10Khz 16 bit 4 Type A and 1 Type B 10Khz 16 bit Analog Input Ranges 0 to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit Resolution 0 to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit Resolution 0 to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit Resolution Output Control Voltage Relay Out Relay Out Relay Out Relay Maximum Resistive Load Rating 2 Amps at 24 VDC and 240 VAC 2 Amps at 24 VDC and 240 VAC 2 Amps at 24 VDC and 240 VAC Maximum Number of PWM Pulse Outputs N A 1 5khz 16 bit 1 5Khz 16 bit Analog Output Ranges O to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit Resolution 0 to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit Resolution 0 to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit Resolution Dimensions WxHxD mm 150x90x76 150x90x76 150x90x76 Programming Software VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer Portable Memo
53. 24 VDC 24 VDC ESCP Relay Out Relay Out Self Healing No External Fusing Required Relay Maximum Resistive Load Rating N A 2 Amps at 24 VDC N A N A 2 Amps at 24 VDC 2 Amps at 24 VDC and 240 VAC and 240 VAC and 240 VAC Dimensions WxHxD mm 95x90x76 95x90x76 95x90x76 95x90x76 95x90x76 95x90x76 www ge ip com GE Intelligent Platforms Control Systems Solutions 225 VersaMax Micro amp Nano Discrete Expansion Units The VersaMax Micro s modular design provides you with remarkable flexibility in a compact control The versatile Micro PLC can support up to four Expansion Units of any mix of discrete or analog IC200UEX009 IC200UEX010 IC200UEX215 IC200UEX213 IC200UEX214 Product Name 14 point 8 120 VAC In 14 point 8 120 VAC In 28 point 28 point 16 28 point 16 6 Relay Out 2 outputs 6 120 VAC Out 16 12 VDC In 12 VDC In 12 24 VDC In 12 24 VDC at 10 amp and 4 outputs 120 240 VAC 12 12 VDC Out Relay Out 12 VDC Out 24 VDC at 2 amp 120 240 VAC Powered 12 VDC Powered Powered Powered Powered Micro Type Restrictions N A N A N A N A N A Number of Discrete Inputs Outputs 8 In 6 Out 8 In 6 Out 16 In 12 Out 16 In 12 Out 16 In 12 Out Power Voltage 120 240 VAC 120 240 VAC 12 VDC 12 VDC 24 VDC Input Power Supply Rating 11 VA 11 VA 8 Watts 8 Watts 5 Watts 24 VDC User Power for Sensors 200 mA 200 mA 200 mA 200 mA 200 mA Input Device Voltage 120 VAC 120 VAC 12 VDC 12 VDC 24 VDC Output Con
54. 265 VAC 47 63 H2 0 265 VAC 47 63 H2 120 240 VAC nominal 120 240 VAC nominal Number of Points 8 in 8 out 8 in 8 out 8 in 8 out Channel to Channel Isolation Yes outputs Yes Yes Load Current per Point 2 0 A for 5 265 VAC 2 0 A for 5 30 VDC 10 mA min 0 5 A max 5 A for 2 0 A 0 2 A for 31 125 VDC 1 cycle 20 ms max inrush Input and Output Response Time On Off ms 1 AC cycle minimum and 2 AC cycle Hz dependent maximum and 10 0 OFF 1 cycle 2 cycle and lt 1 2 cycle lt 1 2 cycle 1 cycle 2 cycle and 10 10 Protection No internal fuses or snubbers Snubber and MOVs each output No internal fuses or snubbers On State Current 4 mA minimum 5 mA minimum 5 mA minimum Off State Current 1 5 mA maximum 2 5 mA maximum 2 5 mA maximum External Power Supply 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal 0 125 VDC 5 24 125 VDC nominal N A 0 265 VAC 47 63 Hz 120 240 VAC nominal Input Impedance 38 5 kOhms reactive at 60 Hz typical 46 3 kOhms reactive at 50 Hz typical 8 6 kOhms reactive at 60 Hz typical 10 32 kOhms reactive at 50 Hz typical 8 6 kOhms reactive at 60 Hz typical 10 32 kOhms reactive at 50 Hz typical Load Current 10mA per point minimum 2 0 Amps for 5 to 265 VAC maximum resistive 2 0 Amps for 5 to 30 VDC maximum resistive 0 2 Amp for 31 to 125 VDC maximum resistive 10 mA minimum per point 0 5 Amaximum per point 5
55. 3 647 to 2 147 463 648 pulses Range 2 147 463 647 to 2 147 463 648 pulses Pulse Output Type 1 Pulse column CW CCW 2 Clock direction signal CK direction 1 Pulse column CW CCW 2 Clock direction signal CK direction Pulse Output Method Line Driver Output Line Driver Output Operating Mode Auto operation and manual operation Auto operation and manual operation Home Function Free homing Low speed homing High speed homing 1 OFF edge High speed homing 2 marker stop Free homing Low speed homing High speed homing 1 OFF edge High speed homing 2 marker stop Manual JOG operation Manual input signal or pulse output by command Manual input signal or pulse output by command Feedrate Override Function 1 to 100 Speed scale rate 1 to 100 Speed scale rate High Speed Input Registration Differential Input Supports Windowing Differential Input Supports Windowing Motion Module I O Assignment Inputs A Channel position data from encoder differential B Channel position data from encoder differential Z Channel position data from encoder differential Positioning finish signal from servo driver COIN Home limit switch input Common for Digital Inputs Jog Forward Jog Reverse Feedrate Override Estop Drive OK Ready Outputs Clockwise Pulse Pulse differential Counter Clockwise Pulse Direction differential Inputs A Channel
56. 45 RS 232 RJ 45 RS 232 RJ 45 RS 232 Protocols SNP SNP X SNP SNP X SNP SNP X SNP SNP X SNP SNP X SNP SNP X Breakless RTU Breakless RTU Breakless RTU Breakless RTU Breakless RTU Breakless RTU Slave 2 and 4 Slave 2 and 4 Slave 2 and 4 Slave 2 and 4 Slave 2 and 4 Slave 2 and 4 wire RTU Slave wire RTU Slave wire RTU Slave wire RTU Slave wire RTU Slave wire RTU Slave Serial Read Serial Read Serial Read Serial Read Serial Read Serial Read and Write and Write and Write and Write and Write and Write Power Voltage 2 VDC 24 VDC 2 VDC 24 VDC 24 VDC 2 VDC Input Power Supply Rating 3 watts internal 3 watts internal 3 watts internal 3 watts internal 3 watts internal 3 watts internal Input Device Voltage 2 VDC 24 VDC 2 VDC 24 VDC 24 VDC 2 VDC Maximum Type A and B Counters 2 Type Aand 1 Type B 10Khz 2 Type Aand 1 Type B 10Khz 2 Type Aand 1 Type B 10Khz 2 Type Aand 1 Type B 10Khz 2 Type Aand 1 Type B 10Khz 2 Type Aand 1 Type B 10Khz 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit Analog Input Ranges O to 10 VDC 8 bit O to 10 VDC 8 bit N A N A N A N A Output Control Voltage Relay Out Relay Out 2 VDC 24 VDC Relay Out Relay Out Relay Maximum Resistive Load Rating 2 Amps at 5 VDC 2 Amps at 5 VDC N A N A 2 Amps at 5 VDC 2 Amps at 5 VDC and 240 VAC and 240 VAC and 240 VAC and 240 VAC Maximum Number of PWM Pulse Outputs
57. 5A per point Isolated VersaMax Discrete Output Module 120 VAC 0 5A per point Isolated VersaMax Discrete Output Module 120 VAC 2 0A per point Isolated 8 points 16 points 8 points Output Voltage 85 132 VAC 47 63 Hz 120 VAC nominal 85 132 VAC 47 63 Hz 120 VAC nominal 85 132 VAC 47 63 Hz 120 VAC nominal Number of Points 8 16 8 Channel to Channel Isolation Yes Yes Yes Load Current per Point 0 5 A per point 0 5 A per point 2 0 A per point Input and Output Response Time On Off ms lt 1 2 cycle lt 1 2 cycle lt 1 2 cycle lt 1 2 cycle lt 1 2 cycle lt 1 2 cycle Protection Snubber and MOVs each output Snubber and MOVs each output Snubber and MOVs each output Points per Common 8 groups of 1 Isolated points Isolated points External Power Supply 85 132 VAC 47 63 Hz 120 VAC nominal 85 132 VAC 47 63 Hz 120 VAC nominal 85 132 VAC 47 63 Hz 120 VAC nominal Load Current 10 mA minimum per point 0 5 A maximum per point 5 0 A for one cycle 20 ms maximum inrush 10 mA minimum per point 0 5 Amaximum per point 5 0 A for one cycle 20 ms maximum inrush 10 mA minimum per point 2 0 A maximum per point 20 A for one cycle 20 ms maximum inrush 5V Backplane Current Consumption mA 70 maximum 140 maximum 85 maximum LED Indicators One LED per point shows individual point ON OFF status logic side OK LED indicates backplane power
58. 6 7 mS max 60 Hz filter frequency Accuracy at 25 C 0 3 typical of full scale 0 5 maximum of full scale 0 1 maximum of full scale 0 3 typical of full scale 0 5 maximum of full scale 0 3 typical of full scale 0 5 maximum of full scale Input Impedance Voltage mode 126 kOhms maximum N A Voltage mode 126 kOhms maximum Voltage mode Current mode 200 Ohms maximum Current mode 200 Ohms maximum 100 kOhms maximum Input Filter Response 5 0 ms N A 5 0 ms N A 5V Backplane Current Consumption mA 125 maximum 15 maximum 130 maximum 200 maximum 3 3V Backplane Current Consumption mA N A 120 maximum N A N A LED Indicators INT PWR LED indicates internally generated field power is present OK LED indicates backplane power is present FLD PWR LED indicates the presence of both logic power and user power OK LED indicates module status INT PWR LED indicates internally generated field power is present OK LED indicates backplane power is present INT PWR LED indicates internally generated field power is present OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50
59. A for 5 265 VAC maximum resistive 2 0 A for 5 30 VDC maximum resistive 0 2 A for 31 125 VDC maximum resistive 0 5 Amps at 30 VDC maximum resistive 2 0 Amps maximum for 100ms inrush 5V Backplane Current Consumption mA 260 maximum 115 maximum LED Indicators One LED per point shows individual point on off state logic side OK LED indicates backplane power is present One LED per point shows individual point on off state logic side OK LED indicates backplane power is present 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 185 VersaMax Discrete Input Modules Discrete input modules receive signals from input devices such as sensors pushbuttons and switches that can have two states on or off open or closed Modules require a carrier base IC2O0CHSxxx C200MDL140 IC200MDL141 IC200MDL143 Product Name VersaMax Discrete Input Module 120 VAC 8 points VersaMax Discrete Input Module 240 VAC 8 points VersaMax Discrete Input Module 120 VAC Isolated 8 points Input Voltage 0 132 VAC 0 264 VAC 0 132 VAC Number of Points 8 8 8 Channel to Channel Isolation No No Yes Input and Outpu
60. CPU is compatible with the application e OEM Password Protection supported e Simple to operate LEDs to show activity error and status Push button to start download and selector switch for direction of download to the PLC or to the memory stick e Designed for the industrial environment UL and CE not Class 1 Div 2 approved PPDD features e Slide switch for direction of data storage e Status and Diagnostic LEDs LEDs Status Error Red Status Green LED On Steady On when there isn t a Memory Stick attached On after button has been pushed and name in PLC matches and when download is complete LED Flashing Flashing when CPU doesn t match or Slow Flash During Download Fast Flash 500msec on 500msec off Memory Stick doesn t have the proper file Slow Flash 1 sec on 1 sec off Flashing if Verify fails Fast Flash when CPU type matches but name in PLC doesn t match LED Off Off during normal conditions with no errors Off prior to button being pushed for download www ge ip com GE Intelligent Platforms Control Systems Solutions 237 VersaMax Micro amp Nano The Portable Program Download Device is simple to use The example below demonstrates the four easy steps of downloading an application and emailing it to a remote location for application upgrade Step 1 Step 4 Slide PPDD selector toward USB memory stick Press Place the USB memory stick in the PPDD slide selector toward PPDD download button The
61. DL650 VersaMax Discrete Input Module 24 VDC Positive Logic 32 points 110 5V 1 C200MDL240 VersaMax Discrete Input Module 120 VAC Positive Logic 16 points 170 5V 2 C200MDL331 VersaMax Discrete Output Module 120 VAC 2 0 A per point Isolated 8 points 980 5V 2 C200MDL940 VersaMax Discrete Output Module Relay 2 0 A per point Isolated Form A 16 points 400 5V 2 C200ALG262 VersaMax Analog Input Module 15 Bit Differential Current 8 Channel 10 5Vand115 3V 2 C200ALG331 VersaMax Analog Output Module 14 Bit Voltage Current 1500 VAC Isolation 8 Channel 1 IC200CHS022 VersaMax Compact I O Carrier Local Box Clamp Connection Style 460 5Vand5 3V IC200BEM002 PLC Network Communications Profibus DP Slave IC200PWB001 VersaMax Power Supply Booster Carrier Supplies power to all modules to the right of booster Requires power supply IC200CHSO06 VersaMax I O Local Communications Carrier 44 5V IC200ETMO01 Bus Transmitter Expansion Module 70 5Vand20 3V IC200ERMO02 Expansion Receiver Module Non lsolated IC200CBL600 Cable Expansion Shielded Single Ended 1M IC200ACC313 DIN rail clips Qty 2 to secure modules on DIN rail BC646MPS101 Logic Developer PLC Standard w Programming Cable Total 2424 5 V and 790 3 V Required 4500 mA available for 5 V and 3 3 V Power Supply Booster required with extra Power Supply to meet power requirements continued on next page 208 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax
62. Logic Developer PLC Nano Micro Programming Cable included and Proficy GlobalCare Complete Upgrades included for 15 months of upgrades IC646MPH101 Logic Developer PDA Single License with Adapters With Logic Developer PDA you can monitor change data view diagnostics force ON OFF and configure machine setup saving you time and increasing productivity 1C752DDZ000 VersaMax DP Operator Interface DataDesigner editor Cables 0 1 meter cable C200CBL501 is included in every expansion base package IC200CBL500 Programming cable RJ 45 to DB 9 pin RS 232 3 Meters IC200CBL501 1 0 Expansion cable 0 1 meter long Qty 5 IC200CBL505 1 0 Expansion cable 0 5 meter long IC200CBL510 O Expansion cable 1 meter long www ge ip com GE Intelligent Platforms Control Systems Solutions 239 VersaMax Micro amp Nano Starter Kits IC200TBX010 ool box Nano 10 and software Includes IC200ONDROO1 24 VDC In Relay Out 24 VDC powered requires an external 24 VDC Supply with software manuals and cables IC646MPH101 IC200TBX110 ool box Nano 10 operator interface and software Includes IC200NDR001 24 VDC In Relay Out 24 VDC powered requires an external 24 VDC Supply VersaMax DataPanel DP45 with programming software and cables IC640VPSO00 IC752DDZ000 IC200CBL555
63. Maximum Resistive Load Rating 2 Amps at 24 VDC 2 Amps at 24 VDC N A N A 2 Amps at 24 VDC and 240 VAC and 240 VAC and 240 VAC Dimensions WxHxD mm 95x90x76 95x90x76 95x90x76 95x90x76 95x90x76 224 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Discrete Expansion Units The VersaMax Micro s modular design provides you with remarkable flexibility in a compact control The versatile Micro PLC can support up to four Expansion Units of any mix of discrete or analog IC200UEX015 IC200UEX013 IC200UEX014 IC200UEX122 IC200UEX012 IC200UEX011 Product Name 14 point 8 12 VDC 14 point 8 12 VDC 14 point 8 24 VDC 14 point 8 24 VDC 14 point 8 24 VDC 14 point 8 24 VDC In 6 12 VDC In 6 Relay Out In 6 24 VDC Out In 6 24 VDC In 6 Relay Out In 6 Relay Out Out 12 VDC 12 VDC 24 VDC Powered Out with ESCP 24 VDC 120 240 VAC Powered Powered 24 VDC Powered Powered Powered Micro Type Restrictions N A N A N A N A N A N A Number of Discrete Inputs Outputs 8 In 6 Out 8 In 6 Out 8In 6 Out 8In 6 Out 8 In 6 Out 8 In 6 Out Power Voltage 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC 120 240 VAC Input Power Supply Rating 4 Watts 4 Watts 4 Watts 4 Watts 4 Watts 13 VA 24 VDC User Power for Sensors 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA Input Device Voltage 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC 24 VDC Output Control Voltage 12 VDC Relay Out
64. O interposing disconnect bases enable the IC200CHS003 to connect to a wide range of termination bases The Relay bases provide additional protection and IC200CHS003 IC200CHS101 IC200CHS102 higher amperage outputs The Disconnect bases enables the user to easily disconnect signals on a per point bases from the I O module IC200CHS111 Product Name VersaMax 1 O Carrier Connector Style Aconnecting cable IC200CBL1xxx and interposing base IC200CHS011 CHS012 CHS014 CHS015 IC200CHS1xx or IC200CHS2xx are required This carrier can be used with all VersaMax I O modules EXCEPT the following due to their high isolation requirements IC200MDL144 Input 240 VAC 4 Point Isolated Module IC200MDL244 Input 240 VAC 8 Point Isolated Module IC200MDD850 Mixed 240 VAC Isolated 4 Point Output Relay 2 0A Isolated 8 Point Module Input or Output Interposing Disconnect Style 16 Points The base has an individual knife switch disconnect for each signal and common terminal and its corresponding pin on the VersaMax cable connector Requires IC200CHS003 and a connecting cable IC200CBL1xxx Expansion Input or Output Interposing Disconnect Style 16 Points The base has an individual knife switch disconnect for each signal and common terminal and its corresponding pin on the VersaMax cable connector Requires a IC200CHS101 main base can not be directly connected to IC200CHS003 1 0 Interposing Relay Base replacea
65. Relay Out 6 12 24 VDC Out 6 12 VDC Out 120 240 VAC 120 240 VAC 2 1 0 A 4 0 5 A 0 7 A 12 VDC Powered Powered 24 VDC Powered Powered Number of Discrete Inputs Outputs 8In 6 Out 8 In 6 Out 8 In 6 Out 8In 6 Out Supports 4 Expansion Units Supports 4 Expansion Units Supports 4 Expansion Units Supports 4 Expansion Units Number of Analog Inputs Outputs Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion units 16 analog in 8 analog out Physical I O Maximum 126 126 126 126 User Program Logic Memory Words 9K 9K 9K 9K Registers Words 256 256 256 256 Analog Pots for Data Adjustment Yes 2 Yes 2 Yes 2 Yes 2 Serial Port Connector Type RJ 45 RS 232 RJ 45 RS 232 RJ 45 RS 232 RJ 45 RS 232 Protocols SNP SNP X Breakless RTU Slave 2 and 4 wire RTU Slave Serial Read SNP SNP X Breakless RTU Slave 2 and 4 wire RTU Slave Serial Read SNP SNP X Breakless RTU Slave 2 and 4 wire RTU Slave Serial Read SNP SNP X Breakless RTU Slave 2 and 4 wire RTU Slave Serial Read and Write and Write and Write and Write Power Voltage 120 240 VAC 120 240 VAC 24 VDC 12 VDC Input Power Supply Rating 11 VA 11 VA 4 Watts 3 Watts 24 VDC User Power for
66. Sensors N A 200 mA 200 mA 200 mA Input Device Voltage 120 VAC 120 VAC 24 VDC 12 VDC Maximum Type A and B Counters N A N A 4 Type A and 1 Type B 4 Type A and 1 Type B 10Khz 16 bit 10Khz 16 bit Output Control Voltage 120 VAC N A 24 VDC 12 VDC Relay Maximum Resistive Load Rating N A 6 2 Amps at 24 VDC and 240 VAC N A N A 2 10 Amps at 24 VDC and 240 VAC Maximum Number of PWM Pulse Outputs N A N A 4 5khz 16 bit 4 5khz 16 bit Dimensions WxHxD mm 95x90x76 95x90x76 95x90x76 95x90x76 Programming Software VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer Portable Memory Module Support No No No No 214 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Micro 14 PLCs The Micro 14 PLC is big on features from up to 14 I O built in expandable to 126 1 0 points to fast cycle times robust instruction set and generous memory to allow more flexible pro gramming And it s all packaged in a sturdy modular design for easy access and long term durability This all in one PLC gives you everything you need to control a wide variety of applications IC200UDRO01 IC200UDRO02 IC200UDR003 Product Name 14 point 8 24 VDC In 6 R
67. TP Modbus TCP server and Tunneling Both Ports SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Ethernet SRTP Modbus TCP server and Tunneling Both Ports SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Ethernet SRTP Modbus TCP server and Tunneling Both Ports SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Ethernet SRTP Modbus TCP server and Tunneling Power Voltage 24 VDC 24 VDC 120 240 VAC 24 VDC Input Power Supply Rating 10 Watts 10 Watts 35 VA 10 Watts 24 VDC User Power 435 mA 435 mA 435 mA 435 mA for Sensors Input Device Voltage 24 VDC 24 VDC 24 VDC 24 VDC Maximum Type A and 4 Type A and 1 Type B 4 Type A and 1 Type B 4 Type A and 1 Type B 4 Type A and 1 Type B B Counters 100Khz 32 bit 100Khz 32 bit 100Khz 32 bit 100Khz 32 bit Output Control Voltage 24 VDC ESCP Self Healing 24 VDC Sink Relay Out Relay Out No External Fusing Required Relay Maximum Resistive N A N A 2 Amps at 24 VDC 2 Amps at 24 VDC Load Rating and 240 VAC and 240 VAC Maximum Number of 4 65Khz 32 bit 4 65Khz 32 bit N A N A PWM Pulse Outputs Dimensions WxHxD mm 150x90x76 150x90x76 150x90x76 150x90x76 Programming Software Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix Proficy Machine E
68. VersaMax Introduction VersaMax I O and Control With its innovative modular architec ture VersaMax combines power and versatility to help provide performance in a compact and affordable control solution The VersaMax product family can be used as O as a PLC and as distrib uted control for up to 4096 I O points With its modular architecture intuitive features and unparalleled ease of use it helps save machine builders and end users time and money Power Supplies pages 180 181 a VersaMax is the first GE Intelligent Platforms control product created using the unique Six Sigma design process Six Sigma combines global research and development techniques extensive customer needs analysis and rigorous quality control standards The VersaMax I O and Control product family features a broad selection of I O modules terminations power supplies and network interface options to enhance your control capability Pee casnecee gs Analog I O Modules pages 195 199 Discrete I O Modules pages 182 194 Network Interface Modules Proficy Machine Edition Proficy Machine Edition is an advanced software environment for the development and maintenance of machine level automation Visualization motion control and execution logic are developed with a single programmer page 205 CPUs page 174 Expansion Modules page 202 Accessories page 207 Carriers pages 175 177 RTD and Thermocouple Modules p
69. Voltage N A N A 24 VDC ESCP Self 24 VDC ESCP 24 VDC Sink 24 VDC Sink Healing No External Self Healing No Fusing Required External Fusing Required Relay Maximum Resistive Load Rating N A N A N A N A N A N A Dimensions WxHxD mm 95x90x76 95x90x76 95x90x76 95x90x76 95x90x76 95x90x76 www ge ip com GE Intelligent Platforms Control Systems Solutions 223 VersaMax Micro amp Nano Discrete Expansion Units The VersaMax Micro s modular design provides you with remarkable flexibility in a compact control The versatile Micro PLC can support up to four Expansion Units of any mix of discrete or analog IC200UERO08 IC200UERO16 IC200UECO08 IC200UEC108 IC200UEC208 Product Name 8 point 8 16 point 16 8 point 4 24 VDC 8 point 4 24 VDC 8 point 4 24 VDC In Relay Out 24 VDC Relay Out 24 VDC In 4 24 VDC Out In 4 24 VDC Sink 4 Relay Out Powered Powered with ESCP Out 24 VDC 24 VDC Protection 24 VDC Powered Powered Powered Micro Type Restrictions N A N A N A N A N A Number of Discrete Inputs Outputs 8 Out 16 Out 4 n 4 Out 4 n 4 Out 4 In 4 Out Power Voltage 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC Input Power Supply Rating 4 Watts 4 Watts 4 Watts 4 Watts 4 Watts 24 VDC User Power for Sensors 200 mA 200 mA 200 mA 200 mA 200 mA Input Device Voltage N A N A 24 VDC 24 VDC 24 VDC Output Control Voltage Relay Out Relay Out 24 VDC ESCP 24 VDC Sink Relay Out Self Healing No External Fusing Required Relay
70. age Relay Out Relay Out Relay Out Relay Maximum Resistive Load Rating 2 Amps at 24 VDC 2 Amps at 24 VDC 2 Amps at 24 VDC and 240 VAC and 240 VAC and 240 VAC Maximum Number of PWM Pulse Outputs 0 0 0 Dimensions WxHxD mm 95x90x76 95x90x76 95x90x76 Programming Software VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer Portable Memory Module Support No No No www ge ip com GE Intelligent Platforms Control Systems Solutions 215 VersaMax Micro amp Nano Micro 23 PLCs The Micro 23 PLC is big on features with 23 discrete I O and two analog inputs and one analog output built in expandable to 135 1 0 points The Micro 23 executes fast cycle times robust instruction set and generous memory to allow more flexible programming And it s all packaged in a sturdy modular design for easy access and long term durability IC200UAL004 IC200UAL005 IC200UAL006 Product Name 23 point 13 12 VDC In 10 Relay Out 2 Analog In and 1 Analog Out 12 VDC Powered 23 point 13 24 VDC In 9 Relay Out 1 24 VDC Out 2 Analog In and 1 Analog Out 24 VDC Powered 23 point 13 24 VDC In 9 Relay Out 1 24 VDC Out 2 Analog In and 1 Analog Out 120 240 VAC Powered Number of Discrete Inputs Outputs 13 I
71. age 200 Configuration Guidelines pages 208 209 I O Interposing Bases pages 178 179 Specialty Modules page 201 Publication Reference Chart Remote I O Units pages 203 204 Serial Communications page 206 GFK 1179 Installation Requirements for Conformance to Standards GFK 1697 VersaMax System AS i Network Master Module User s Manual GFK 1503 VersaMax PLC User s Manual GFK 1847 Remote I O Manager User s Manual GFK 1504 VersaMax Modules Power Supplies and Carriers User s Manual GFK 1852 VersaMax Serial to Ethernet Adapter User s Manual GFK 1533 VersaMax System DeviceNet Communications Modules User s Manual GFK 1860 VersaMax System Ethernet Network Interface Unit User s Manual GFK 1534 VersaMax System Profibus Network Modules User s Manual GFK 1868 Proficy Machine Edition Getting Started Guide GFK 1535 VersaMax System Genius Network Interface Unit User s Manual GFK 1876 VersaMax Ethernet Station Manager Manual GFK 1563 VersaMax I O and Industrial Networking Application Guide IC690CDU002 InfoLink for PLC CD ROM www ge ip com GE Intelligent Platforms Control Systems Solutions 173 VersaMax CPUs VersaMax CPUs supply a number of features usually found only in PLCs with larger foot prints including up to 128K of memory for application programs floating point math and real time clock With a modular and scalable architecture the VersaMax CPU is ideal for standalone control applica
72. alog I O Channels 0 to 10VDC 4 to 20mA 6 Analog 1 0 Channels 4 0 to 10 VDC 10 VDC 6 Analog I O Channels 4 0 to 10 VDC 10 VDC 6 Analog I O Channels 4 0 to 10 VDC 10 VDC 24 VDC Powered 4 to 20 mA 0 to 20 mA In 4 to 20 mA 0 to 20 mA In 4 to 20 mA 0 to 20 mA In 2 0 to 10 VDC 4 to 20 mA 2 0 to 10 VDC 4 to 20 mA 2 0 to 10 VDC 4 to 20 mA 0 to 20 mA Out 12 VDC 0 to 20 mA Out 24 VDC 0 to 20 mA Out 120 240 VAC Powered Powered Powered Micro Type Restrictions N A N A N A N A Number of Analog Inputs Outputs 4 Channels In Voltage or Current 4 Channels In 2 Channels Out Voltage or Current 4 Channels In 2 Channels Out Voltage or Current 4 Channels In 2 Channels Out Voltage or Current Power Voltage 24 VDC 12 VDC 24 VDC 120 240 VAC Input Power Supply Rating 3 Watts 2 25 Watts 3 Watts 15 VA 24 VDC User Power for Sensors 200 mA 200 mA 200 mA 200 mA Analog Input Ranges 0 10V 10 23V Max 0 10V 10 23V Max 0 20 mA 20 47 mA Max 4 20 mA 12 bit resolution 0 10V 10 23V Max 0 10V 10 23V Max 0 20 mA 20 47 mA Max 4 20 mA 12 bit resolution 0 10V 10 23V Max 0 10V 10 23V Max 0 20 mA 20 47 mA Max 4 20 mA 12 bit resolution 0 10V 10 23V Max 0 10V 10 23V Max 0 20 mA 20 47 mA Max 4 20 mA 12 bit resolution Analog Output Ranges N A 0 to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit r
73. ates expansion bus communication status Dimensions W x H x D 2 63 66 8 mm x 5 04 128 mm not including the height of power supply 2 63 66 8 mm x 5 04 128 mm not including the height of power supply 37 mm 1 45 in x 5 04 128 mm 202 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Remote I O Units A Remote I O Unit connects VersaMax I O modules to a host PLC or computer via a variety of networks which makes it easy to include VersaMax 1 0 in Genius Profibus DP DeviceNet or Ethernet installations Together the Remote I O Unit and its modules form an I O station capable of providing up to 256 points of I O C200DB1001 C200EB1001 Product Name Remote I O DeviceNet Network Interface Unit Slave Remote I O Ethernet Network Interface Unit Protocol Supported DeviceNet Slave EGD and Modbus TCP Server Distance 500Kbps 100m bus length and branches totaling lt 39m 250Kbps 250m bus length and branches totaling lt 78m 125Kbps 500m bus length and branches totaling lt 156m 100 Meters max drop length 10 100Mbaud I O Discrete Points Includes both discrete and analog Up to 128 bytes of inputs 2 byte status word Up to 128 bytes of outputs 2 byte control word 1024 bytes maximum both discrete and analog l 2048 points Q 2048 points 1 0 Analog Words Includes both discrete and analog Up to 128 bytes of inputs 2 byte stat
74. ax Micro PLC offers the flexibility of modular design and a variety of built in features including up to 64 I O points expandable to 170 I O points fast cycle times a robust cia Proficy Machine Edition Proficy Machine Edition is an advanced software environment for the development and maintenance of machine level automation Visualization motion control and execution logic are developed with a single programmer Publication Reference Chart VersaMax Micro PLCs and Nano PLCs User s Manual instruction set and extensive memory IC690CDU002 InfoLink for PLC CD ROM that multiplies your programming options Expansion Units pages 223 233 al Portable Program Download Device PPDD pages 237 238 Accessories pages 239 240 Lo VersaMotion Servo Motors and Amplifiers pages 243 250 Configuration Guidelines pages 241 242 VersaMax Nano and Micro Selection Guide Features Nano 10 Micro 14 Micro 23 Micro 28 Micro 20 Micro 40 Micro 64 Built in Discrete I O 6 in 4out 8 in 6 out 13 in 10 out 16 in 12 out 12 in 8 out 24 in 16 out 40 in 24 out Built in Analog I O 1 on some models none 2 in 1 out none none none none I O Expansion Units none Up to 4 units Up to 4 units Up to 4 units Up to 4 units Up to 4 units Up to 4 units Logic Memory Words 2K 9K 9K 9K 24K 24K 24K Data Storage Words 256 256 2K 2K 32K 32K 32K Scan Time msec K 1 3 msec 1 1 msec 1 1 msec 1 1 ms
75. aximum Range 18 30 VDC including ripple Current consumption 125 mA maximum Range 18 30 VDC including ripple Current consumption 125 mA maximum Resolution 4 uA 8 counts 2 5 mV 8 counts Input 2 5 mV 8 counts Output 5 mV 16 counts Update Rate 0 3 ms maximum 0 3 ms maximum 0 3 ms maximum Accuracy at 25 C 0 3 typical of full scale 0 5 maximum of full scale 0 3 typical of full scale 0 5 maximum of full scale 0 3 typical of full scale 0 5 maximum of full scale Input Impedance 200 Ohms maximum 120 kOhms minimum 125 kOhms minimum Input Filter Response 5 0 ms 5 0 ms 5 0 ms LED Indicators FLD PWR LED indicates field power is present OK LED indicates backplane power is present FLD PWR LED indicates field power is present OK LED indicates backplane power is present FLD PWR LED indicates field power is present OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 199 VersaMax
76. ble relays fused 8 amps replaceable 16 points The relays on these interposing terminals are intended to be controlled with standard 24 VDC 0 5A VersaMax output modules IC200MDL740 and IC200MDL750 using IC200CHS003 base and connected by IC200CBL1xxx Field Termination Type Integrated Non Integrated Non Integrated Non Integrated Wiring Termination Style Connector Box Box Box Removable Terminals Connectors N A No No No Input Voltage N A All discrete modules supported All discrete modules supported 24 VDC from MDL740 except MDL144 244 331 730 except MDL144 244 331 730 and MDL750 and MDD840 843 850 and MDD840 843 850 Output Voltage N A All discrete modules supported All discrete modules supported 0 125 VDC 5 24 125 VDC except MDL144 244 331 730 except MDL144 244 331 730 nominal 0 265 VAC 47 63 Hz and MDD840 843 850 and MDD840 843 850 120 240 VAC nominal Load Current per Point N A N A N A 8 0 A for 5 265 VAC 2 0 A for 5 30 VDC 0 2 A for 31 125 VDC Replaceable Fuse Protection N A N A N A Replaceable Fuse Points per Common N A N A N A solated Per Point Dimensions W x H x D Cables 66 8 mm 2 63 in x 133 4 mm 5 25 in x 70 mm 2 75 in not including the height of the DIN Rail Requires a IC200CBL1xxx cable 115 mm 4 5 in x 126 mm 4 95 in x 65 mm 2 6 in not including the height of the DIN Rail Requires a IC200CBL1xxx cable 115 mm 4 5 in x 126 mm
77. ces such as contactors indicator lamps and interposing relays that can also have two states Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single compact module Modules require a carrier base IC200CHSxxx IC200MDD850 IC200MDD851 Product Name VersaMax Discrete Mixed Modules 240 VAC Input Isolated 4 points Output Relay 2 0 A Isolated 8 points VersaMax Discrete Mixed Modules 5 12 VDC Input 16 points Output 12 24 VDC 16 points Input Voltage 0 264 VAC 47 63 Hz 240 VAC nominal 0 to 15 VDC 5 12 VDC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal Output Voltage 10 2 to 30 VDC 12 24 VDC nominal Number of Points 8 out 4 in 16 out 16 in Channel to Channel Isolation Yes No Load Current per Point 2 0A 0 5 Amps at 30 VDC maximum resistive 2 0 Amps maximum for 100ms inrush Input and Output Response Time On Off ms 1 cycle 2 cycle and 10 10 0 25ms maximum 0 2ms ON and 1 0ms OFF maximum Protection No internal fuses or snubbers No internal fuses or snubbers On State Current 4 mA minimum 1 45mA minimum Off State Current 1 5 mA maximum 0 to 0 7 mA maximum External Power Supply N A 10 2 to 30 VDC 12 24 VDC nominal Input Impedance 38 5 kOhms reactive at 60 Hz typical 46 3 kOhms reactive at 50 Hz typical 2 4kOhms typical 12 VDC Load Current 10 mA per point minimum 2 0
78. cro or Nano PLC without user configuration C200DTX200 IC200DTX450 IC200DTX650 IC200DTX850 Product Name Operator Interface for changing timer counter register values 2x16 character LCD backlight display and 6 operation keys No stored messaging PLC stores messages Requires IC200CBL550 Operator Interface with up to 200 stored messages 2x16 character LCD backlight display and 6 function keys Requires IC200CBL555 or equivalent Operates on external 24 VDC Operator Interface with up to 200 stored messages 4x16 character LCD backlight display and 8 function keys Requires IC200CBL555 cable or equivalent Operates on external Operator Interface with up to 200 stored messages 4x20 character LCD backlight display 8 function keys and numeric keypad Requires IC200CBL555 cable or equivalent cable or equivalent 40 mA 24 VDC 80 mA Operates on external Operates on 5 VDC 24 VDC 50 mA 100 mA from Micro or Nano Characters Per Line 16 16 16 20 Function Keys 0 6 8 8 Numeric Keypad o 0 0 Yes Memory Size Number of Messages Messages stored in PLC 200 stored in operator interface 200 stored in operator interface 200 stored in operator interface DataPanel Dimensions WxHxD mm 108x60x27 108x60x45 96x96x44 182x101x37 Number of Lines 2 2 4 4 Display Type LCD Display with Backlight LCD Display with Backlight LCD Display with Backlight LCD Display with
79. dition Logic Developer 5 0 Service Pack 3 Hotfix Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix Portable Memory Module Support Yes Yes Yes Yes www ge ip com GE Intelligent Platforms Control Systems Solutions 219 VersaMax Micro amp Nano Micro 40 PLC The Micro 40 PLC is big on features expandable to 152 I O points to fast cycle times robust instruction set and generous memory to allow more flexible programming The optional sec ond port provides you with the option of an additional RS 232 port RS 485 USB or Ethernet The serial expansion ports come with two analog input channels A user friendly memory module is available to easily download changes to the controller without the need of a PC And it s all packaged in a sturdy modular design for easy access and long term durability This all in one PLC gives you everything you need to control a wide variety of applications IC200UDD040 IC200UDD240 IC200UDR140 IC200UDRO40 IC200UDR440 Product Name Micro 40 24 24 VDC In Micro 40 24 24 VDC In Micro 40 24 24 VDC In Micro 40 24 24 VDC In Micro 40 24 24 VDC In 16 24 VDC Source Out 16 24 VDC Sink Out 16 Relay Out 2 0 amps 16 Relay Out 2 0 amps 16 Relay Out 2 0 amps 0 7 amps with ESCP 24 VDC Powered 120 240 VAC Powered 24 VDC Powered 12 24 VDC Powered protection 24 VDC Powered Number
80. ec 1 1 msec 1 1 msec 1 1 msec Battery Backed RAM Super Cap only Super Cap only Yes and Super Cap Yes and Super Cap Yes and Super Cap Yes and Super Cap Yes and Super Cap Real Time Clock none none Yes Included Yes Included Yes Included Yes Included Yes Included Ports Available 1 RS 232 1 RS 232 1 RS 232 and 1 RS 232 and 1 RS 232 and 1 RS 232 and 1 RS 232 and 1 RS 485 1 RS 485 second port second port second port optional RS 232 RS 485 USB or optional RS 232 RS 485 USB or optional RS 232 RS 485 USB or Ethernet Ethernet Ethernet Ethernet Option Yes VersaMax SE Yes VersaMax SE Yes VersaMax SE Yes VersaMax SE Yes on second port Yes on second port Yes on second port High Speed Counter Upto4at10Khz Upto 4 at 10Khz Up to 4 at 10Khz Upto4at10Khz Upto 4 at 100Khz Upto 4at 100Khz Up to 4 at 100Khz 16 bit 16 bit 16 bit 16 bit 32 bit 32 bit 32 bit Pulse Train PWM Up to 4 at 5Khz Up to 4 at 5Khz Up to 4 at 5Khz Up to 4 at 5Khz Up to 4 at 65Khz Up to 4 at 65Khz Up to 4 at 65Khz 16 bit 16 bit 16 bit 16 bit 32 bit 32 bit 32 bit Motion Commands N A N A N A N A Find Home Find Home Find Home Go Home Jog Go Home Jog Go Home Jog Ramp Ramp Ramp Blended Move Blended Move Blended Move 4 Consecutive Moves 4 Consecutive Moves 4 Consecutive Moves Write Register Values to Internal Flash No Yes Yes Yes Yes Yes Yes On Line Program Support No No No No Yes with Firmware 3 9 Yes Yes amp Hardware
81. elay Out 120 240 VAC Powered 14 point 8 24 VDC In 6 Relay Out 24 VDC Powered 14 point 8 12 VDC In 6 Relay Out 12 VDC Powered Number of Discrete Inputs Outputs 8 In 6 Out Supports 4 Expansion Units 8 In 6 Out Supports 4 Expansion Units 8 In 6 Out Supports 4 Expansion Units Number of Analog Inputs Outputs Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion units 16 analog in 8 analog out Physical I O Maximum 126 126 126 User Program Logic Memory Words 9K 9K 9K Registers Words 256 256 256 Analog Pots for Data Adjustment Yes 2 Yes 2 Yes 2 Serial Port Connector Type RJ 45 RS 232 RJ 45 RS 232 RJ 45 RS 232 Protocols SNP SNP X Breakless RTU Slave 2 and 4 wire RTU Slave Serial Read SNP SNP X Breakless RTU Slave 2 and 4 wire RTU Slave Serial Read SNP SNP X Breakless RTU Slave 2 and 4 wire RTU Slave Serial Read and Write and Write and Write Power Voltage 120 240 VAC 24 VDC 12 VDC Input Power Supply Rating 13 VA 4 Watts 3 Watts 24 VDC User Power for Sensors 200 mA 200 mA 200 mA Input Device Voltage 24 VDC 24 VDC 12 VDC Maximum Type A and B Counters 4 Type A and 1 Type B 10Khz 16 bit 4 Type A and 1 Type B 10Khz 16 bit 4 Type A and 1 Type B 10Khz 16 bit Output Control Volt
82. elay Out 24 VDC 24 VDC ESCP Self Healing No External Fusing Required Relay Maximum Resistive Load Rating N A 10 2 Amps at 24 VDC and 240 VAC N A N A 2 10 Amps at 24 VDC and 240 VAC Maximum Number of PWM Pulse Outputs N A N A 4 5Khz 16 bit 4 5khz 16 bit Dimensions WxHxD mm 150x90x76 150x90x76 150x90x76 150x90x76 Programming Software VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer VersaPro 1 1 or greater Proficy Machine Edition Logic Developer Portable Memory Module Support No No No No www ge ip com GE Intelligent Platforms Control Systems Solutions 217 VersaMax Micro amp Nano Micro 28 PLC The Micro 28 PLC is big on features with the built in 28 I O expandable to 140 1 0 points to fast cycle times two built in serial ports robust instruction set and generous memory to allow more flexible programming And it s all packaged in a sturdy modular design for easy access and long term durability This all in one PLC gives you everything you need to control a wide variety of applications IC200UDD212 IC200UDRO05 IC200UDRO06 IC200UDR228 IC200UDR010 Product Name 28 point 16 12 VDC In 28 point 16 24 VDC In 28 point 16 12 VDC In 28 point 16 24 VDC In 28 point 16 24 VDC In 12 12 VDC Out 0 7A 11 Relay Out
83. ersaMotion family of servo motors offers high servo performance in a compact package The motors range from 100 W to 3 kW with continuous torque ratings from 0 3 Nm to 14 3 Nm All motors have metric mounting configurations and include a shaft key and oil seal For vertical axes or applications that need to hold position during power loss motors with 24 VDC holding brakes are available Motors are matched with the VersaMotion amplifiers IC800VMMO1L IC800VMMO02L IC800VMMO04L IC800VMMO7L Product Name VersaMotion 100 Watt VersaMotion 200 Watt VersaMotion 400 Watt VersaMotion 750 Watt Rated Output kW 0 1 0 2 0 4 0 75 Rated Torque Nm 0 32 0 64 1 27 2 39 Maximum Torque Nm 0 96 1 92 3 82 7 16 Rated Speed RPM 3000 3000 3000 3000 Maximum Speed RPM 5000 5000 5000 5000 Rated Current Amps 0 9 1 55 2 6 51 Maximum Current Amps 27 4 65 78 153 Rotor Moment of Inertia Kg m2 x 1074 0 037 0 177 0 277 1 13 Mechanical Time Constant msec 0 75 0 8 0 53 0 63 Torque Constant KT Nm 0 36 0 41 0 49 0 47 Voltage Constant KE mV rmp 13 6 16 17 4 17 2 Armature Resistance Ohm 93 2 79 1 55 0 42 Armature Inductance mH 24 10 84 6 84 3 53 Electrical Time Constant msec 2 58 3 89 4 43 8 37 Maximum Radial Shaft Load Newton 78 4 196 196 245 Maximum Thrust Shaft Load Newton 39 2 68 68 98 www ge ip com GE Intelligent Platforms Control Systems Solutions 247 VersaMax Micro amp Nano Motors
84. es C200CBL500 or equivalent IC200ACC450 Simulator for VersaMax Nano 10 6 Inputs IC200ACC451 Simulator for VersaMax Micro 14 Micro 23 and Micro 28 8 Inputs IC200UMB001 Flash Memory Board for program download and compatible with Micro 64 128Kbytes External Power Supplies IC690PWRO24 24 VDC 5 Amp Output Power and 120 230 VAC Input Power Power Supply IC690PWR124 24 VDC 10 Amp Output Power and 120 230 VAC Input Power Power Supply Stepper Controller Motors and Cables More Information in Motion Solutions Catalog GFA 483 IC800PCUB00300 epping Motor Power Amplifier 12 48 VDC 4 Amp IC800CUBDB15ADP S Motor Cube or Power Cube DB15 to screw terminal connector adaptor IC800PCUBDINMTG ower Cube DIN Rail Mounting Adaptor MTR 1216 N D E 0 epping Motor Nema23 Series Wdg Holding Torque 61 oz in 0 43 Nano meters MTR 1220 N D E 0 epping Motor Nema23 Series Wdg Holding Torque 116 oz in 0 82 Nano meters MTR 1221 N D E 0 epping Motor Nema23 Series Wdg Holding Torque 124 oz in 0 87 Nano meters MTR 1231 N D E 0 epping Motor Nema23 Series Wdg Holding Torque 236 oz in 1 68 Nano meters MTR 1235 N D E 0 epping Motor Nema23 Series Wdg Holding Torque 185 oz in 1 31 Nano meters MTR 1331 J N D E 0 epping Motor Nema34 Series Wdg Holding Torque 327 oz in 2 31 Nano meters MTR 1N31 I N D S 0 P S S S S S S S epping Motor Nema34 Series Wdg H
85. esolution 0 to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit resolution 0 to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit resolution Dimensions WxHxD mm 95x90x76 95x90x76 95x90x76 95x90x76 230 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Analog Expansion Units The VersaMax Micro analog 1 0 is versatile and the Micro PLC can support up to four Analog Expansion Units allowing you to expand up to 16 inputs and 8 outputs IC200UEX724 IC200UEX734 IC200UEX726 C200UEX736 Product Name 4 RTD PT 100 Channels IN 120 240 VAC Powered 4 RTD PT 100 Channels IN 24 VDC Powered 4 RTD PT 100 Channels IN 2 Analog Channels OUT 0 to 10 VDC 4 to 20 mA 0 to 20 mA Out 24 VDC Powered 4 RTD PT 100 Channels IN 2 Analog Channels OUT 0 to 10 VDC 4 to 20 mA 0 to 20 mA Out 120 240 VAC Powered Micro Type Restrictions 16 bit supported on Mircro 20 40 64 only 16 bit supported on Mircro 20 40 64 only 16 bit supported on Mircro 20 40 64 only 16 bit supported on Mircro 20 40 64 only Number of Analog Inputs Outputs 4 Channels RTD In 4 Channels RTD In 4 Channels RTD In 2 Channels Out Voltage or Current 4 Channels RTD In 2 Channels Out Voltage or Current Power Voltage 24 VDC 120 240 VAC 24 VDC 120 240 VAC Input Powe
86. esponse N A N A 24 Hz 20 5V Backplane Current Consumption mA 200 maximum 150 maximum 100 maximum 3 3V Backplane Current Consumption mA N A N A N A LED Indicators INT PWR LED indicates internally generated field power is present OK LED indicates backplane power is present INT PWR LED indicates internally generated field power is present OK LED indicates backplane power is present INT PWR LED indicates internally generated field power is present OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 196 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Analog Output Modules Analog output modules provide voltage or current signals to analog output devices Modules require a carrier base IC200CHSxxx IC200ALG320 IC200ALG321 IC200ALG322 Product Name VersaMax Analog Output Module 12 Bit Current 4 Channel VersaMax Analog Output Module 12 Bit 0 10V Voltage 4 Channel VersaMax Analog Output Module 12 Bit 10V Voltage 4 Channel Outpu
87. grades included for 15 months of upgrades IC200DTX850 Operator Interface with up to 200 stored messages 4x20 character LCD backlight display 8 function keys and numeric keypad Requires C200CBL550 cable or equivalent Operates on external 24 VDC 50 mA C752DDZ000 VersaMax DP Operator Interface DataDesigner editor Options to consider C646MPH101 Logic Developer PDA Single License with Adapters With Logic Developer PDA you can monitor change data view diagnostics force ON OFF and configure machine setup saving you time and increasing productivity C200ACC451 Simulator for VersaMax Micro 14 Micro 23 and Micro 28 8 Inputs C690PWRO24 24 VDC 5 Amp Output Power and 120 230 VAC Input Power Power Supply www ge ip com GE Intelligent Platforms Control Systems Solutions 241 VersaMax Micro amp Nano Configuration for Micro 64 Example Application needing 45 24 VDC discrete inputs 32 outputs Twelve Relay and Twenty 24 VDC 3 Stepper motors Nema 23 Holding Torque 124 oz in 0 87 Nano meters 2 100Khz Encoders Application also requires Color Touch Graphic Display Qty Part Number Description 1 IC200UDD064 Micro 64 40 24 VDC In 24 24 VDC Source Out 0 7 amps with ESCP protection 24 VDC Powered 1 IC200ACC414 Long Term Battery for Micro 23 Micro 28 and Micro 64 1 C200UEX211 28 point 16 24 VDC In 12 Relay Out 120 240 VAC Powered 1 C200USB001 RS 232 option board with 2 0 10 VDC
88. guration Guidelines Examples of Typical Application Configuration for Nano 10 Applications needing less than 6 24 VDC inputs and 4 relay outputs Description Qty Part Number 1 IC200NDROO1 10 point 6 24 VDC In 4 Relay Out 24 VDC Powered 1 BC646MPM101 Proficy Logic Developer PLC Nano Micro Programming Cable included and Proficy GlobalCare Complete Upgrades included for 15 months of upgrades Options to consider IC646MPH101 Logic Developer PDA Single License with Adapters With Logic Developer PDA you can monitor change data view diagnostics force ON OFF and configure machine setup saving you time and increasing productivity IC200ACC450 Simulator for VersaMax Nano 10 6 Inputs IC690PWRO24 24 VDC 5 Amp Output Power and 120 230 VAC Input Power Power Supply Configuration for Micro 14 Example Application needing 12 24 VDC discrete inputs 6 relay outputs and 3 Analog inputs with 24 VDC power Qty Part Number Description IC200UDRO02 14 point 8 24 VDC In 6 Relay Out 24 VDC Powered IC200UEI008 8 point 24 VDC In 24 VDC Powered IC200UEX626 6 Analog 1 0 Channels 4 0 to 10 VDC 10 VDC 4 to 20 mA 0 to 20 mA In 2 0 to 10 VDC 4 to 20 mA 0 to 20 mA Out 24 VDC Powered BC646MPM101 Proficy Logic Developer PLC Nano Micro Programming Cable included and Proficy GlobalCare Complete Upgrades included for 15 months of upgrades Options to consider
89. h Proficy programming software and cables IC646MPM101 IC752DDZ000 IC200CBL555 IC200TBX340 ool box Micro 40 operator interface and software Includes IC200UDR140 24VDC In Relay Out AC Power Supply IC200USB001 RS 232 option board with 2 0 10VDC analog in with VersaMax DataPanel DP45 with Proficy Logic Developer programming software and cables IC646MPM101 IC752DDZ000 IC200CBL555 IC200TBX440 ool box Micro 40 stepper motor Power Cube amplifier and software Includes IC200UDD040 24VDC In 24VDC Out DC Power Supply IC200USB001 RS 232 option board with 2 0 10VDC analog in stepping motor amplifier IC800PCUB00300 stepping motor MTR 1216 N D E 0 stepper cable CBL 12 MP 10 Power Cube Flying Lead interface cable IC800PCUBC02S030 with Proficy software manuals and cables IC646MPM101 IC200TBX540 ool box Micro 40 QuickPanel color touch screen and software Includes IC200UDR140 24VDC In Relay Out AC Power Supply IC200UEMO01 Ethernet option board QuickPanel Display IC754VSIO6STD with Proficy software manuals and cables BC646MBL001 IC200TBX064 ool box Micro 64 and software Includes IC200UDD064 24 VDC In 24 VDC Out DC Power Supply IC200USB001 RS 232 option board with 2 0 10 VDC analog in with Proficy software manuals and cables IC646MPM101 IC200TBX164 ool box Micro 64 and software Includes IC200UDR164 24 VDC In Relay Out AC Power Supply IC200USB001 RS 232 option board with 2 0 10 VDC analog in with
90. igent Platforms Control Systems Solutions www ge ip com
91. ires IC200CHS003 base and connecting cable IC200CBL1xxx VersaMax 1 0 Carrier Interposing Box Thermocouple Compensation Requires IC200CHS003 base and connecting cable IC200CBL1xxx VersaMax I O Carrier Interposing Spring Clamp Requires IC200CHS003 base and connecting cable IC200CBL1xxx IC200MDD850 Mixed 240 VAC Isolated 4 Point Output Relay 2 0A Isolated 8 Point Module Field Termination Type Integrated Non Integrated Non Integrated Integrated Non Integrated Wiring Termination Style Connector Barrier Box Box Thermocouple Spring Compensation Orientation on Module on Base Vertical N A N A N A N A Dimensions W x H x D 66 8 mm 2 63 in x 133 4 mm 5 25 in x 70 mm 2 75 in not including the height of DIN Rail 110 5 mm 4 35 in x 105 4 mm 2 63 in x 70 mm 2 75 in not including the height of DIN Rail 110 5 mm 4 35 in x 105 4 mm 2 63 in x 70 mm 2 75 in not including the height of DIN Rail 110 5 mm 4 35 in x 105 4 mm 2 63 in x 70 mm 2 75 in not including the height of DIN Rail 110 5 mm 4 35 in x 105 4 mm 2 63in x 70 mm 2 75 in not including the height of DIN Rail Cables Requires a IC200CBL1xxx cable Requires a IC200CBL1xxx cable Requires a IC200CBL1xxx cable Requires a IC200CBL1xxx cable Requires a IC200CBL1xxx cable www ge ip com GE Intelligent Platforms Control Systems Solutions 177 VersaMax I O Interposing Bases VersaMax I
92. ite functions and initial configuration wizard e Calculation tools to determine proper conversion from encoder counts to desired user programming units e Three channel digital oscilloscope to display and record drive status on line e Alarm history and status monitor diagnostic screens e Digital I O set up and monitoring GE Intelligent Platforms Control Systems Solutions 243 VersaMax Micro amp Nano Servo Amplifier Part Number Sequence IC800VMA 04 2 Input Voltage 2 220VAC Single Phase Rated Power 01 100 Watts 02 200 Watts 04 400 Watts 07 750 Watts 10 1000 Watts 20 2000 Watts 30 3000 Watts Example IC800VMA042 is a 400 watt 220VAC servo amplifier Amplifiers Technical Data Permissible Frequency Fluctuation 50 60 Hz 5 Resolution Quadrature Feedback Counts 2500 ppr 10000 cpr Control Modes Position Velocity Torque Dynamic Brake Built in Position Control Mode Maximum Input Pulse Frequency 500KPPS Line Driver Maximum 200KPPS Open Collector Pulse Type Pulse Direction CW CCW A B Phase Command Source External pulse train Internal parameters Torque Limit Operation Yes Feed Forward Compensation Yes Analog Commands Voltage Range 0 to 10VDC Torque and Velocity Control Mode Command Source External analog signal Internal parameters Speed Contro
93. l Range 1 5000 Speed Control Frequency Response Maximum 450 Hz Torque Control Mode Permissible Time for Overload 8 seconds under 200 rated output Communications Interface RS 232 RS 485 RS 422 Environmental Altitude Altitude 1000 meters above sea level or lower Environmental Operating Temperature 0 to 55 C Forced cooling for operation above 55 C Environmental Storage Temperature 20 C to 65 C Environmental Humidity 0 to 90 Non condensing Vibration lt 20 Hz 9 8 m sec sec 1G 20 to 50 Hz 5 88 m sec sec 0 6 G Standards IEC EN 61800 5 1 UL 508C TUV C tick 244 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Amplifiers The VersaMotion family of servo amplifiers offers a cost effective solution for a broad range of motion applications These versatile amplifiers support simple stand alone positioning capability using up to 8 stored motion profiles or can be connected to any motion controller using an analog or pulse command interface A built in touchpad and display provides con venient access to configuration parameters and system information The serial interface supports multi drop system configurations and Modbus communication protocol IC800VMA012 IC800VMA022 IC800VMA042 IC800VMA072 Product Name VersaMotion Amplifier VersaMotion Amplifier VersaMotion Amplifier VersaMotion Amp
94. lays on these interposing terminals are intended to be controlled with standard 24 VDC 0 5A VersaMax output modules IC200MDL740 and IC200MDL750 using IC200CHS003 base and connected by IC200CBL1xxx Expansion base Field Termination Type Non Integrated Non Integrated Non Integrated Connection Style Box Box Box Removable Terminals Connectors No Yes Yes Input Voltage 24 VDC from MDL740 and MDL750 24 VDC from MDL740 and MDL750 24 VDC from MDL740 and MDL750 Output Voltage 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal Load Current per Point 8 0 A for 5 265 VAC 2 0 A for 5 30 VDC 0 2 A for 31 125 VDC Replaceable Fuse 8 0 A for 5 265 VAC 2 0 A for 5 30 VDC 0 2 A for 31 125 VDC Replaceable Fuse 8 0 A for 5 265 VAC 2 0 A for 5 30 VDC 0 2 A for 31 125 VDC Replaceable Fuse Protection Replaceable Fuse Replaceable Fuse Replaceable Fuse Points per Common Isolated Per Point Isolated Per Point Isolated Per Point Dimensions W x H x D Cables 253 7 mm 9 9 in x 126 mm 4 95 in x 73 mm 2 8 in not including the height of the DIN Rail N A 253 7 mm 9 9 in x 126 mm 4 95 in x 73 mm 2 8 in not including the height of the DIN Rail Requires
95. lifier Rated Output Power 100W 200W 400W 750W Voltage Frequency Three phase or Single phase 220VAC 50 60 Hz Three phase or Single phase 220VAC 50 60 Hz Three phase or Single phase 220VAC 50 60 Hz Three phase or Single phase 220VAC 50 60 Hz Permissible Voltage Fluctuation Three phase 170 255VAC Single phase 200 255VAC Three phase 170 255VAC Single phase 200 255VAC Three phase 170 255VAC Single phase 200 255VAC Three phase 170 255VAC Single phase 200 255VAC Cooling System Convection Convection Convection Fan Cooling Electronic Gear Ratio Gear Ratio N M where N 1 32767 M 1 32767 1 50 lt N M lt 200 Gear Ratio N M where N 1 32767 M 1 32767 1 50 lt N M lt 200 Gear Ratio N M where N 1 32767 M 1 32767 1 50 lt N M lt 200 Gear Ratio N M where N 1 32767 M 1 32767 1 50 lt N M lt 200 IC800VMA102 IC800VMA202 IC800VMA302 Product Name VersaMotion Amplifier VersaMotion Amplifier VersaMotion Amplifier Rated Output Power Voltage Frequency 1KW Three phase or Single phase 220VAC 50 60 Hz 2KW Three phase 220VAC 50 60 Hz 3KW Three phase 220VAC 50 60 Hz Permissible Voltage Fluctuation Three phase 170 255VAC Single phase 200 255VAC Three phase 170 255VAC Three phase 170 255VAC Cooling System Fan Cooling Fan Cooling Fan Cooling Electronic
96. mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 195 VersaMax Analog Input Modules Analog input modules receive signals from current and voltage input devices Modules require a carrier base IC200CHSxxx IC200ALG262 IC200ALG263 IC200ALG264 Product Name VersaMax Analog Input Module 15 Bit Differential Current VersaMax Analog Input Module 15 Bit Voltage 15 Channel VersaMax Analog Input Module 15 Bit Current 15 Channel 8 Channel Input Range 0 to 20mA or 4 to 20mMA 10 VDC 0 to 20mA or 4 to 20mA Number of Channels 8 15 15 External Power Supply None None None Resolution 4 to 20mA 0 5micro Amp 1 count 0 to 20mA 0 625micro Amp 1 count Bipolar mode 0 3125 mV 1 count 4 to 20mA 0 5micro Amp 1 count 0 to 20mA 0 625micro Amp 1 count Update Rate 7 5 ms 7 5 ms 7 5 ms Accuracy at 25 C 0 3 typical of full scale 0 5 maximum of full scale 0 3 typical of full scale 0 5 maximum of full scale 0 3 typical of full scale 0 5 maximum of full scale Input Impedance Current mode 100 kOhms maximum Voltage mode 100 kOhms maximum Voltage mode 100 kOhms maximum Current mode 200 Ohms maximum Input Filter R
97. mption 100 mA maximum plus load currents 2A inrush maximum 270 mA maximum all 12 outputs at full scale 4 20 mA 5 counts Current mode 381 nA nominal Resolution 1 25 mV 4 counts 4 20 mA 5 counts 1 25 mV 4 counts 2 5 UA 12 7 bits 2 5 uA 12 7 bits Voltage mode 381 uV nominal 0 20 mA 4 counts 2 5 uA 13 bits 0 20 mA 4 counts 2 5 uA 13 bits Update Rate 15 0 ms maximum 15 0 ms maximum 10 0 ms maximum 15 ms maximum 7 ms maximum Accuracy at 25 C 0 3 typical of full scale 0 3 of full scale typical 0 3 typical of full scale 0 3 of full scale typical 0 1 maximum of full scale 0 5 maximum of full scale 0 5 of full scale max 0 5 maximum of full scale 0 5 of full scale max 1 of full scale max 1 of full scale max 5V Backplane Current Consumption mA 50 maximum 50 maximum 50 maximum 50 maximum 10 maximum 3 3V Backplane Current Consumption mA N A N A N A N A 115 maximum LED Indicators FLD PWR LED indicates field power is present OK LED indicates backplane power is present FLD PWR LED indicates field power is present OK LED indicates backplane power is present FLD PWR LED indicates field power is present OK LED indicates backplane power is present FLD PWR LED indicates the presence of both logic power and user power OK LED indicates module status FLD PWR LED indicates field power is present OK LED indicates backplane power is
98. n 10 Out Supports 4 Expansion Units 13 In 10 Out Supports 4 Expansion Units 13 In 10 Out Supports 4 Expansion Units Number of Analog Inputs Outputs 2 analog in 1 analog out built in and supports up to 4 analog expansion units 16 analog in 8 analog out 2 analog in 1 analog out built in and supports up to 4 analog expansion units 16 analog in 8 analog out 2 analog in 1 analog out built in and supports up to 4 analog expansion units 16 analog in 8 analog out Physical I O Maximum 135 135 135 User Program Logic Memory Words 9K 9K 9K Registers Words 2K 2K 2K Analog Pots for Data Adjustment yes 2 yes 2 yes 2 Serial Port Connector Type RJ 45 RS 232 port 1 and DB 15 RS 485 on port 2 RJ 45 RS 232 port 1 and DB 15 RS 485 on port 2 RJ 45 RS 232 port 1 and DB 15 RS 485 on port 2 Protocols Port 1 SNP SNP X Breakless Port 2 SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Port 1 SNP SNP X Breakless Port 2 SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Port 1 SNP SNP X Breakless Port 2 SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write Power Voltage 12 VDC 24 VDC 120 240 VAC Input Power Supply Rating 8 Watts 8 Watts 34 VA 24 VDC User Power for Sensors 200 mA
99. of 1 On State Current 5 mA minimum 7 MA minimum 1 0 mA minimum Off State Current 2 5 mA maximum 3 mA maximum 0 to 0 1 mA maximum Input Impedance 8 6 kOhms reactive at 60 Hz typical 38 5 kOhms reactive at 60 Hz typical 74 K Ohm typical at 125 VDC 10 32 kOhms reactive at 50 Hz typical 46 3 kOhms reactive at 50 Hz typical 5V Backplane Current Consumption mA 100 maximum 60 maximum 40 maximum LED Indicators One LED per point shows individual point ON OFF status OK LED indicates backplane power is present One LED per point shows individual point ON OFF status OK LED indicates backplane power is present One LED per point shows individual point ON OFF status OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 188 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Discrete Input Modules Discrete input modules receive signals from input devices such as sensors pushbuttons and switches that can have two states on or off open or closed Modules require a carrier
100. og in with VersaMax DataPanel DP45 with Proficy Logic Developer programming software and cables IC646MPM101 IC752DDZ000 IC200CBL555 IC200TBX420 ool box Micro 20 stepper motor Power Cube amplifier and software Includes IC200UDD064 24VDC In 24VDC Out DC Power Supply IC200USB001 RS 232 option board with 2 0 10VDC analog in stepping motor amplifier IC800PCUB00300 stepping motor MTR 1216 N D E 0 stepper cable CBL 12 MP 10 Power Cube Flying Lead interface cable IC800PCUBC02S030 with Proficy software manuals and cables IC646MPM101 IC200TBX520 ool box Micro 20 QuickPanel color touch screen and software Includes IC200UDR164 24VDC In Relay Out AC Power Supply IC200UEM001 Ethernet option board QuickPanel Display IC754VSIO6STD with Proficy software manuals and cables BC646MBL001 IC200TBX040 ool box Micro 40 and software Includes IC200UDD040 24VDC In 24VDC Out DC Power Supply IC200USB001 RS 232 option board with 2 0 10VDC analog in with Proficy software manuals and cables IC646MPM101 IC200TBX140 ool box Micro 40 and software Includes IC200UDR140 24VDC In Relay Out AC Power Supply IC200USB001 RS 232 option board with 2 0 10VDC analog in with Proficy software manuals and cables IC646MPM101 IC200TBX240 ool box Micro 40 operator interface and software Includes IC200UDD040 24VDC In 24VDC Out DC Power Supply IC200USB001 RS 232option board with 2 0 10VDC analog in with VersaMax DataPanel DP45 wit
101. ogic 32 points 490 5V IC200MDL940 VersaMax Discrete Output Module Relay 2 0 A per point Isolated Form A 16 points 2 IC200CHS022 VersaMax Compact I O Carrier Local Box Clamp Connection Style IC200ACC313 DIN rail clips Qty 2 to secure modules on DIN rail BC646MPS101 Logic Developer PLC Standard w Programming Cable Total 580 5 Vand 100 3 V 820 mA remaining 1500 mA available for 5 V and 3 3 V Options to consider IC646MPH101 Logic Developer PDA Single License with Adapters With Logic Developer PDA you can monitor change data view diagnostics force ON OFF and configure machine setup saving you time and increasing productivity IC690PWRO24 24 VDC 5 Amp Output Power and 120 230 VAC Input Power Power Supply 100 5V IC200ACC003 EZ Program Store CPU RS485 Port Update Device Configuration for Controller Application requiring 20K of Registers 60 24 VDC inputs 15 AC Inputs 12 AC Outputs and 20 Relay outputs also 16 Analog Inputs 12 Isolated Analog Outputs and 24 VDC power supply Also requires Profibus Slave connection Power Supply Current Required Qty Part Number Description 80 5Vand 650 3 V 1 C200CPU005 VersaMax PLC CPU 128K Configurable User Memory 2 Ports RS 232 and RS 485 3 C200PWR002 24 VDC Power Supply with Expanded 3 3 V Logic side supply of 1 5 amps maximum Up to 1 0 amp can be allocated for 3 3 V usage 100 5V 2 C200M
102. olding Torque 605 oz in 4 27 Nano meters CBL 12 MP 10 Power Cable MTR 1216 1221 or 1231 Stepping Motor 10 Ft CBL 12 MP 20 Power Cable MTR 1216 1221 or 1231 Stepping Motor 20 Ft CBL 12 MP 30 Power Cable MTR 1216 1221 or 1231 Stepping Motor 30 Ft CBL 13 MP 10 Power Cable MTR 1220 MTR 1235 MTR 13xx MTR 14xx amp MTR 1Nxx Series Stepping Motors 10 Ft CBL 13 MP 20 Power Cable MTR 1220 MTR 1235 MTR 13xx MTR 14xx amp MTR 1Nxx Series Stepping Motors 20 Ft CBL 13 MP 30 Power Cable MTR 1220 MTR 1235 MTR 13xx MTR 14xx amp MTR 1Nxx Series Stepping Motors 30 Ft IC800PCUBC02S030 Power Cube Flying Lead I O Interface Cable 200 Steps Rev amp Power Save Enabled 3 Meters IC800PCUBC02S050 Power Cube Flying Lead Interface I O Cable 200 Steps Rev amp Power Save Enabled 5 Meters IC800PCUBC04S030 Power Cube Flying Lead Interface I O Cable 400 Steps Rev amp Power Save Enabled 3 Meters IC800PCUBC04S050 Power Cube Flying Lead Interface I O Cable 400 Steps Rev amp Power Save Enabled 5 Meters IC800PCUBC10S030 Power Cube Flying Lead Interface I O Cable 1000 Steps Rev amp Power Save Enabled 3 Meters IC800PCUBC10S050 Power Cube Flying Lead Interface I O Cable 1000 Steps Rev amp Power Save Enabled 5 Meters Programming and Trouble Shooting Tools IC646MPM101 Proficy Logic Developer PLC Nano Micro Programming Cable No Upgrades included BC646MPM101 Proficy
103. or Sensors 435 mA 435 mA 435 mA 435 mA Input Device Voltage 24 VDC 24 VDC 24 VDC 24 VDC Output Control Voltage Relay Out Relay Out 24 VDC Sourced 24 VDC Sink Relay Maximum Resistive Load Rating 2 Amps at 24 VDC 2 Amps at 24 VDC N A N A and 240 VAC and 240 VAC Dimensions WxHxD mm 190x90x76 190x90x76 190x90x76 190x90x76 228 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Analog Expansion Selection Guide Input Range 0 to 10V Input Range 10V to 10V Input Range millivolt Output Range 0 to 20mA Input Range Thermocouple 50mV 0 10 VDC Model Module Input Power 4 to 20mA RTD Pt 100 Type K J E S T B N 100mV 0 20 mA IC200UEX616 12 VDC 4in 2 out 4in 2 ou IC200UEX624 24 VDC 4in IC200UEX626 24 VDC 4in 2 out 4in 2 ou IC200UEX636 120 240 VAC 4in 2 out 4in 2 ou IC200UEX724 24 VDC 4in IC200UEX726 24 VDC 4in 2 out 4in 2 ou IC200UEX734 120 240 VAC 4in IC200UEX736 120 240 VAC 4in 2 out 4in 2 ou IC200UEX824 24 VDC 4in 4in IC200UEX826 24 VDC 4in 2 out 4in 2 out 4in 2 ou www ge ip com GE Intelligent Platforms Control Systems Solutions 229 VersaMax Micro amp Nano Analog Expansion Units The VersaMax Micro analog 1 0 is versatile and the Micro PLC can support up to four Analog Expansion Units allowing you to expand up to 16 inputs and 8 outputs IC200UEX624 IC200UEX616 IC200UEX626 IC200UEX636 Product Name 4 An
104. or closed Discrete output modules send control signals to devices such as contactors indicator lamps and interposing relays that can also have two states Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single compact module Modules require a carrier base IC200CHSxxx IC200MDD844 IC200MDD845 C200MDD846 Product Name VersaMax Discrete Mixed Modules 24 VDC Positive Logic Input 16 Output 24 VDC 0 5 A 16 points VersaMax Discrete Mixed Modules 24 VDC Positive Logic Input 16 Output Relay 2 0A Isolated 8 points VersaMax Discrete Mixed Modules 120 VAC Input 8 points Outpoints Relay 2 0A Isolated 8 points Input Voltage 24 VDC 24 VDC 120 VAC Output Voltage 24 VDC 0 125 VDC 5 24 125 VDC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 0 265 VAC 47 63 Hz 120 240 VAC nominal 120 240 VAC nominal Number of Points 16 in 16 out 16 in 8 out 8 in 8 out Channel to Channel Isolation No Yes outputs Yes outputs Load Current per Point 0 5 A for 30 VDC 2 0 A for 5 265 VAC 2 0 A for 5 30 VDC 0 2 A for 31 125 VDC 2 0 A for 5 265 VAC 2 0 A for 5 30 VDC 0 2 A for 31 125 VDC Input and Output Response Time On Offims 0 5 and 0 2 ON 1 0 OFF 0 5 and 10 1 AC cycle minimum and 2 AC cycle Hz dependent maximum and 10 0 OFF Protection No internal fuses No internal fuses or snubbers No internal fuses or snubbers On State Current
105. otection Short circuit overload reverse polarity Short circuit overload reverse polarity N A Total Output Current 1 5 A maximum 1 5 A maximum N A 3 3 V Output Current 0 25 A maximum 1 0 A maximum N A 5V Output Current 1 5 A minus the 3 3 V 1 5 A minus the 3 3 V N A current used maximum current used maximum Dimensions W x H x D 49 mm 1 93 in x 133 4 mm 5 25 in x 39 mm 1 54 in not including the height of the carrier or the DIN Rail 49 mm 1 93 in x 133 4 mm 5 25 in x 39 mm 1 54 in not including the height of the carrier or the DIN Rail 66 8 mm 2 63 in x 133 4 mm 5 25 in x 70 mm 2 75 in not including the height of DIN Rail www ge ip com GE Intelligent Platforms Control Systems Solutions 181 VersaMax Discrete Mixed I O Modules Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single compact module Discrete input modules receive signals from input devices such as sensors push buttons and switches that can have two states on or off open or closed Discrete output modules send control signals to devices such as contactors indicator lamps and interposing relays that can also have two states Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single compact module Modules require a carrier base IC200CHSxxx IC200MDD840 IC200MDD842 IC200MDD843 Product Name VersaMax Discrete Mixed Modules 24 VDC Po
106. oth Ports SNP SNP X Both Ports SNP SNP X Both Ports SNP SNP X Breakless RTU Master and Breakless RTU Master and Breakless RTU Master and Breakless RTU Master and Breakless RTU Master and Slave 2 and 4 wire RTU Slave Slave 2 and 4 wire RTU Slave Slave 2 and 4 wire RTU Slave Slave 2 and 4 wire RTU Slave Slave 2 and 4 wire RTU Slave SNP Master Serial Read and SNP Master Serial Read and SNP Master Serial Read and SNP Master Serial Read and SNP Master Serial Read and Write Ethernet SRTP Modbus Write Ethernet SRTP Modbus Write Ethernet SRTP Modbus Write Ethernet SRTP Modbus Write Ethernet SRTP Modbus TCP server and Tunneling TCP server and Tunneling TCP server and Tunneling TCP server and Tunneling TCP server and Tunneling Power Voltage 24 VDC 24 VDC 120 240 VAC 24 VDC 12 24 VDC Input Power Supply Rating 10 Watts 10 Watts 35 VA 10 Watts 10 Watts 24 VDC User Power for Sensors 435 mA 435 mA 435 mA 435 mA 120 mA Input Device Voltage 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC Maximum Type A and 4 Type A and 1 Type B 4 Type A and 1 Type B 4 Type A and 1 Type B 4 Type A and 1 Type B 4 Type A and 1 Type B B Counters 100Khz 32 bit 100Khz 32 bit 100Khz 32 bit 100Khz 32 bit 100Khz 32 bit Output Control Voltage 24 VDC ESCP Self Healing 24 VDC Sink Relay Out Relay Out Relay Out No External Fusing Required Relay Maximum Resistive N A N A 2 Amps at 24 VDC 2 Amp
107. pact I O Carrier Local Spring Clamp Connection Style Field Termination Type Integrated Integrated Wiring Termination Style Local Box Local Spring Orientation on Module on Base Vertical Vertical Dimensions W x H x D 66 8 mm 2 63 in x 163 5 mm 6 45 in x 70 mm 2 75 in not including the height of DIN Rail 66 8 mm 2 63 in x 163 5 mm 6 45 in x 70 mm 2 75 in not including the height of DIN Rail Cables N A N A www ge ip com GE Intelligent Platforms Control Systems Solutions 175 VersaMax Carriers VersaMax provides several types of snap together I O carriers and interposing terminals to provide maximum wiring flexibility as well as module hot insertion and removal VersaMax carriers support IEC box style spring style and barrier style terminals and are also avail able as snap on auxiliary terminal strips and interposing terminals that can be mounted separately and connected to a connector style carrier by an I O cable IC200CHS001 IC200CHS002 IC200CHS005 Product Name VersaMax I O Carrier Local Barrier Style VersaMax I O Carrier Local Box Style VersaMax I O Carrier Local Spring Clamp Connection Style Field Termination Type Integrated Integrated Integrated Wiring Termination Style Barrier Box Spring Orientation on Module on Base Horizontal Horizontal Horizontal Dimensions W x H x D 110 5 mm 4 35 in x 139 7 mm 5 5 in x 70 mm 2 75 in no
108. r Supply Rating 3 Watts 15 VA 3 Watts 15 VA 24 VDC User Power for Sensors 200 mA 200 mA 200 mA 200 mA Analog Input Ranges 2 and 3 wire types PT 100 16 bit 2 and 3 wire types PT 100 16 bit 2 and 3 wire types PT 100 16 bit 2 and 3 wire types PT 100 16 bit Analog Output Ranges N A N A 0 to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit resolution 0 to 10 VDC 10 24V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit resolution Dimensions WxHxD mm 95x90x76 95x90x76 95x90x76 95x90x76 www ge ip com GE Intelligent Platforms Control Systems Solutions 231 VersaMax Micro amp Nano Analog Expansion Units The VersaMax Micro analog 1 0 is versatile and the Micro PLC can support up to four Analog Expansion Units allowing you to expand up to 16 inputs and 8 outputs IC200UEX824 IC200UEX826 Product Name 4 Thermocouple or mV Input Channels 24 VDC Powered 4 Thermocouple or mV Input Channels and 2 Analog Output Channels 24 VDC Powered Micro Type Restrictions 16 bit supported on Micro 20 40 64 only 16 bit supported on Micro 20 40 64 only Number of Analog Inputs Outputs 4 Channels Thermocouple In or 50mV or 100mV 24 VDC Power Supply 4 Channels Thermocouple In or 50mV or 100mV and 2 channel analog outputs 24 VDC Power Supply Power Voltage 24 VDC 24 VDC Input Powe
109. r Supply Rating 3 Watts 3 Watts 24 VDC User Power for Sensors 200 mA 200 mA Analog Input Ranges Type K J E S T B N 50mV 100mV 12 bit 16 bit 4th QTR 2009 Type K J E S T B N 50mV 100mV 12 bit 16 bit 4th QTR 2009 Analog Output Ranges N A 0 to 10 VDC 10 24 V max 0 to 20 mA 20 5 mA max 4 to 20 mA 20 5 mA max 12 bit resolution Dimensions WxHxD mm 95x90x76 95x90x76 232 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Micro Motion Expansion Unit The Micro Motion expansion module is ideal for either Micro integrated motion control or standalone motion control over serial or Ethernet networking The Micro Motion expansion module is loaded with features and supports a wide range of stepper and servo control The module supports a powerful function set with up to 256 move profiles stored on the module Micro Motion module supports the Portable Memory device removable Flash device for easy program storage of the motion moves IC200UMM002 IC200UMM102 Product Name VersaMax Micro 2 Axis Motion Module VersaMax Micro 2 Axis Motion Module Micro Type Restrictions Micro 20 40 64 Support Only Micro 20 40 64 Support Only Number of Axis 2 2 Follower Mode Axis A can follow B or Axis B can follow A within the module only Axis A can follow B or Axis B can follow A within the module only
110. rent 0 5 Amaximum 5V Backplane Current Consumption mA 30 LED Indicators One LED per point shows individual point on off state logic side OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 201 VersaMax Expansion Modules Expansion Modules can be used to extend a VersaMax PLC or I O station to include up to seven additional groups of up to eight modules each providing the architectural flexibility to accommodate larger applications IC200ERM001 IC200ERM002 IC200ETM001 Product Name Expansion Receiver Module Isolated Expansion Receiver Module Non Isolated Bus Transmitter Expansion Module Expansion Type Receiver Receiver Transmitter Distance Up to 2460 feet Up to 50 feet N A 5 V Backplane Current Consumption mA 430 70 44 3 3 V Backplane Current Consumption mA 20 20 N A LED Indicators PWR LED indicates 5 VDC power status EXP RX LED indicates status of the expansion bus SCAN indicates whether CPU NIU is scanning 1 0 in expansion racks PWR LED indicates 5 VDC power status EXP RX LED indicates expansion bus communications status SCAN indicates whether CPU NIU is scanning I O in expansion racks PWR LED indicates 5 VDC power status EXP TX LED indic
111. revision B with Firmware 3 9 with Firmware 3 9 www ge ip com GE Intelligent Platforms Control Systems Solutions 211 VersaMax Nano and Micro Powerful Instruction Set Bit Operation Functions Logic AND Logic OR Exclusive OR Logical Invert Shift Right Left Rotate Right Left Bit Test Set Clear Masked Compare Bit Position Bit Sequencer Control Functions Do I O Call End Subroutines Comments Master Control Relay Service Request PID Table Functions e Array Move e Search ntroduction Data Move Functions Move Block Move Block Clear Shift Register Communications Request Motion Moves High Speed Counter Serial Read Write Modbus Master Conversion Functions BCD 4 Signed Integer Double Precision Signed Integer Real Real to Word Truncate Real Number Math and Numerical Functions e Modulo division Scaling Square Root Relation Functions Equal Not Equal Greater Than Less Than Greater or Equal Less or Equal Range Relay Functions e Contacts Coils e Fault and No Fault Contacts e Alarm Contacts Timer and Counters Time tick Contacts On delay Stopwatch timer On delay timer Off delay timer Up Counter Down Counter Motion Functions l e Find Home Go Home e Trigonometric Functions e Ramp e Logarithmic Exponential e Jog e Convert Radians e Blended Move i e Stop Move Ne
112. rop The serial port can be used to interface with a wide range of Modbus slave devices such as controllers VFDs bar code readers marques and much more The data is transferred to and from the NIU over the Genius LAN and is compatible with any controller that supports Genius Global Data 1C200CMM020 Product Name Serial Communications Expansion Module Module Type Modbus Master NIU Type Supported Genius Number of Serial Communications Modules Up to 2 per Genius NIU 1 0 Station Number of RTU slaves per Serial Communications Module 1 to 247 Serial Port Type RS 485 15 pin subminiature D connector For RS 232 communications an RS 485 to RS 232 adapter such as IC690ACC901 can be used Adapter IC690ACC901 can be installed with its right angle cable hanging down RS 485 supports both 2 wire and 4 wire electrical interfaces Baud Rate Supported 1200 2400 4800 9600 and 19200 and half or full duplex operation COMMREQ command memory AQ required in the GENERIC_COMM module hardware configuration Depends on individual COMMREQ content Minimum 22 words Maximum 64 words RTU Master Commands 65520 Initialize RTU Master Port 8000 Clear RTU Master Diag Status 8001 Read RTU Master Diag Status 8002 Send RTU Read Force Preset Query 8003 Send RTU Diagnostic Query Power Consumption 460 mA maximum from 5 V output 5 mA from 3 3 V output Dimensions W x H x D
113. ry Module Support No No No 216 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Micro 28 PLC The Micro 28 PLC is big on features with the built in 28 I O expandable to 140 1 0 points to fast cycle times two built in serial ports robust instruction set and generous memory to allow more flexible programming And it s all packaged in a sturdy modular design for easy access and long term durability This all in one PLC gives you everything you need to control a wide var IC200UAA007 iety of applications IC200UAR028 IC200UDD110 1C200UDD120 Product Name 28 point 16 120 VAC In 28 point 16 120 VAC In 28 point 16 24 VDC In 28 point 16 24 VDC In 12 120 VAC Out 12 Relay Out 12 24 VDC Out 6 1 0 A 6 12 24 VDC Out 6 1 0 A 6 120 240 VAC Powered 120 240 VAC Powered 0 5 A 24 VDC Powered 0 5 A 24 VDC Powered Number of Discrete Inputs Outputs 16 In 12 Out 16 In 12 Out 16 In 12 Out 16 In 12 Out Supports 4 Expansion Units Supports 4 Expansion Units Supports 4 Expansion Units Supports 4 Expansion Units Number of Analog Inputs Outputs Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion uni
114. ry Storage System flash battery System flash battery System flash battery System flash battery backed RAM backed RAM backed RAM backed RAM Battery Backed Real time Clock Yes Yes Yes Yes 5V Backplane Current Consumption mA 40 with no EZ Store attached 140 when EZ Store attached 40 with no EZ Store attached 140 when EZ Store attached 80 with no EZ Store attached 180 when EZ Store attached 160 with no EZ Store attached 260 when EZ Store attached 3 3V Backplane Current 100 100 290 650 Consumption mA Requires a power supply Requires a power supply with 3 3 VDC expanded with 3 3 VDC expanded Dimensions W x H 2 63 66 8 mm x 5 04 128 mm 2 63 66 8 mm x 5 04 128 mm 4 20 106 7 mm x 5 04 128 mm 4 95 126 mm x 5 04 128 mm 174 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Carriers VersaMax provides several types of snap together I O carriers and interposing terminals to provide maximum wiring flexibility as well as module hot insertion and removal VersaMax carriers support IEC box style spring style and barrier style terminals and are also avail able as snap on auxiliary terminal strips and interposing terminals that can be mounted separately and connected to a connector style carrier by an I O cable IC200CHS022 IC200CHS025 Product Name VersaMax Compact I O Carrier Local Box Clamp Connection Style VersaMax Com
115. s Logic Input 20 points Output Relay 2 0 A 12 points VersaMax Discrete Mixed Modules 24 VDC Pos Logic Input 16 Output 24 VDC 0 5 A with ESCP VersaMax Discrete Mixed Modules 24 VDC Positive Logic Input 10 Output Relay 6 Input Voltage 24 VDC 24 VDC 24 VDC Output Voltage 0 125 VDC 5 24 125 VDC nominal 24 VDC 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal Number of Points 20 in 12 out 16 in 16 out 10 in 6 out Channel to Channel Isolation No No No Load Current per Point 2 0 A for 5 265 VAC 2 0 A for 5 30 VDC 0 5 A for 30 VDC 2 0 A for 5 265 VAC 2 0 A for 5 30 VDC 0 2 A for 31 125 VDC Input and Output Response Time On Offims 0 5 and 10 0 5 and 0 5 0 5 and 10 Protection No internal fuses or snubbers overcurrent protection free wheeling diodes Short circuit protection No internal fuses or snubbers On State Current 2 0 5 5 mA 2 0 5 5 MA 2 0 5 5 MA Off State Current 0 0 5 mA 0 0 5 mA 0 0 5 mA External Power Supply 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal 18 30 VDC 24 VDC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal Input Impedance 10 kOhms maximum 10 kOhms maximum 10 kOhms maximum Load Current 2 0 A for 5 265 VAC or 5 30 VDC 0 2 A for 31 125 VDC 0 5 Amp at 30 VDC maximum re
116. s at 24 VDC 2 Amps at 24 VDC Load Rating and 240 VA and 240 VA and 240 VA Maximum Number of 4 65khz 32 bit 4 65kKhz 32 bit N A N A N A PWM Pulse Outputs Dimensions WxHxD mm 150x90x76 150x90x76 150x90x76 150x90x76 150x90x76 Programming Software Proficy Machine Edition Proficy Machine Edition Proficy Machine Edition Proficy Machine Edition Proficy Machine Edition Logic Developer 5 0 Logic Developer 5 0 Logic Developer 5 0 Logic Developer 5 0 Logic Developer 5 0 Service Pack 3 Hotfix Service Pack 3 Hotfix Service Pack 3 Hotfix Service Pack 3 Hotfix Service Pack 3 Hotfix Portable Memory Yes Yes Yes Yes Yes Module Support 220 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Micro 64 PLC The Micro 64 PLC is big on features expandable to 176 I O points to fast cycle times robust instruction set and generous memory to allow more flexible programming The optional second port provides you with the option of an additional RS 232 port RS 485 USB or Ethernet The serial expansion ports come with two analog input channels A user friendly memory module is available to easily download changes to the controller without the need of a PC And it s all packaged in a sturdy modular design for easy access and long term durability This all in one PLC gives you everything you need to control a wide variety of applications IC200UDD064 IC200UDD164 IC200UDR164 IC200UDRO64 Prod
117. se Does not include 24 VDC power supply for inputs IC200PKG103 1 0 Starter Kit DeviceNet Contains DBI001 PWR101 MDD845 CHS002 ACC302 CBLO01 GFK 1533 GFK 1504 690CDRO002 Infolink coffee mug and plastic carry case Does not include 24 VDC power supply for inputs IC200PKG104 1 0 Starter Kit Ethernet Contains EBI001 PWR101 MDD845 CHS002 ACC302 CBLO01 GFK 1534 GFK 1504 Machine Edition Infolink coffee mug and plastic carry case Does not include 24 VDC power supply for inputs www ge ip com GE Intelligent Platforms Control Systems Solutions 207 VersaMax Config u ration G uidel Ines For a multiple rack expansion system connect the cable from the expansion port on the Expansion Transmitter to the Expansion Receivers as shown below If all the Expansion 7 Receivers are the Isolated type IC 200ERM001 the maximum overall cable length is 750 When configuri nga VersaMax Modular the followi ng gu ide meters If the expansion bus includes any non isolated Expansion Receivers IC200ERMO02 lines should be considered the maximum overall cable length is 15 meters 1 All 1 0 modules require an I O Carrier IC200CHS001 002 003 005 022 or 025 VersaMax PLC or I O Station Main Rack 0 2 When an I O Connector Carrier IC200CHS003 is selected a cable IC200CBL6xx and interposing remote base IC200CHS011 012 014 or 015 are required 3 When configuring a system the power cons
118. server Modbus Master Modbus Master Modbus Slave Modbus Slave Modbus Slave Serial Read Serial Read and Write Serial Read and Write Analog Support on Communications Module No Analog Support Two Analog Inputs 0 to 10 VDC 10 bits Two Analog Inputs 0 to 10 VDC 10 bits No Analog Support Memory Module Board Support Yes Yes Yes Yes Programming Support Yes SRTP only Yes Yes Yes Programming Software Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix Proficy Machine Edition Logic Developer 5 0 Service Pack 3 Hotfix www ge ip com GE Intelligent Platforms Control Systems Solutions 235 VersaMax Micro amp Nano Ethernet Communication Option The VersaMax SE enables the VersaMax Micro and Nano to easily be connected to an Ethernet LAN via the VersaMax SE The user can easily down load upload and monitor VersaMax Micro and Nano controllers IC200SETO01 Product Name Ethernet to Serial Network Module Ethernet Port 10 100Mbits port supporting RJ45 connection Serial Port One RS 232 and one RS 485 port up to 16 devices supported Communications Configurations Communication configurations include Ethernet SRTP to SNP or Modbus TCP to Modbus Slave Power Voltage 12 24 VDC
119. sistive 2 0 Amps maximum for 100ms inrush 10mA per point minimum 8 0A maximum per module 2 0 Amps for 5 to 265 VAC maximum resistive 2 0 Amps for 5 to 30 VDC maximum resistive 0 2 Amp for 31 to 125 VDC maximum resistive 5V Backplane Current Consumption mA 375 maximum 100 maximum 190 maximum LED Indicators One LED per point shows individual point on off state logic side OK LED indicates backplane power is present One LED per point shows individual point on off state logic side OK LED indicates backplane power is present One LED per point shows individual point on off state logic side OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 182 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Discrete Mixed I O Modules Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single compact module Discrete input modules receive signals from input devices such as sensors push buttons and switches that can have two states on or off open
120. t ON OFF status OK LED indicates backplane power is present One LED per point shows individual point ON OFF status OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 187 VersaMax Discrete Input Modules IC2O0CHSxxx IC200MDL243 IC200MDL244 Discrete input modules receive signals from input devices such as sensors pushbuttons and switches that can have two states on or off open or closed Modules require a carrier base IC200MDL631 Product Name VersaMax Discrete Input Module 120 VAC Isolated 16 points VersaMax Discrete Input Module 240 VAC Isolated 8 points VersaMax Discrete Input Module 125 VDC Pos Neg Logic Isolated 8 points Input Voltage 0 132 VAC 0 264 VAC 0 150 VDC 125 VDC nominal Number of Points 16 8 8 isolated inputs Channel to Channel Isolation Yes Yes Yes Input and Output Response Time On Off ms 1 cycle 2 cycles 1 cycle 2 cycles 0 5 maximum Points per Common 16 groups of 1 8 groups of 1 8 groups
121. t Range 4 20 mA 0 10 VDC 10 VDC Number of Channels 4 4 4 External Power Supply Range 18 30 VDC including ripple Current consumption 160 mA maximum including load current Range 18 30 VDC including ripple Current consumption 125 mA maximum Range 18 30 VDC including ripple Current consumption 125 mA maximum Resolution 4 uA 8 counts 2 5 mV 8 counts 5 mV 16 counts Update Rate 0 3 ms maximum 0 3 ms maximum 0 3 ms maximum Accuracy at 25 C 0 3 typical of full scale 0 5 maximum of full scale 0 3 typical of full scale 0 5 maximum of full scale 0 3 typical of full scale 0 5 maximum of full scale 5V Backplane Current Consumption mA 50 maximum 50 maximum 50 maximum 3 3V Backplane Current Consumption mA N A N A N A LED Indicators FLD PWR LED indicates field power is present OK LED indicates backplane power is present FLD PWR LED indicates field power is present OK LED indicates backplane power is present FLD PWR LED indicates field power is present OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in
122. t Response Time On Off ms 1 cycle 2 cycles 1 cycle 2 cycles 1 cycle 2 cycles Points per Common 1 group of 8 1 group of 8 8 groups of 1 On State Current 5 mA minimum 7 MA minimum 5 mA minimum Off State Current 2 5 mA maximum 1 5 mA maximum 2 5 mA maximum Input Impedance 8 6 kOhms reactive at 60 Hz typical 10 32 kOhms reactive at 50 Hz typical 38 5 kOhms reactive at 60 Hz typical 46 3 kOhms reactive at 50 Hz typical 8 6 kOhms reactive at 60 Hz typical 10 32 kOhms reactive at 50 Hz typical 5V Backplane Current Consumption mA 55 maximum 55 maximum 50 maximum LED Indicators One LED per point shows individual point ON OFF status OK LED indicates backplane power is present One LED per point shows individual point ON OFF status OK LED indicates backplane power is present One LED per point shows individual point ON OFF status OK LED indicates backplane power is present Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors 186 GE Intelligent Platforms Control Systems Solutions www ge ip com
123. t including the height of DIN Rail 110 5 mm 4 35 in x 139 7 mm 5 5 in x 70 mm 2 75 in not including the height of DIN Rail 110 5 mm 4 35 in x 139 7 mm 5 5 in x 70 mm 2 75 in not including the height of DIN Rail Cables N A N A N A 176 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Carriers IC200CHS003 IC200CHS011 IC200CHS012 IC200CHS014 VersaMax provides several types of snap together O carriers and interposing terminals to provide maximum wiring flexibility as well as module hot insertion and removal VersaMax carriers support IEC box style spring style and barrier style terminals and are also available as snap on auxiliary terminal strips and interposing terminals that can be mounted separately and connected to a connector style carrier by an I O cable IC200CHS015 Product Name Connector Style A connecting cable IC200CBL1xxx and interposing base IC200CHS011 CHS012 CHS014 CHS015 VersaMax I O Carrier VersaMax I O Carrier Interposing Barrier Style Requires IC200CHS003 base and connecting cable IC200CBL1xxx IC200CHS1xx or IC200CHS2xx are required This carrier can be used with all VersaMax I O modules EXCEPT the following due to their high isolation requirements IC200MDL144 Input 240 VAC 4 Point Isolated Module IC200MDL244 Input 240 VAC 8 Point Isolated Module VersaMax I O Carrier Interposing Box Style Requ
124. t of the carrier or the mating connectors 110 mm 4 3 in x 66 8 mm 2 63 in x 50 mm 1 956 in not including the height of the carrier or the mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 193 VersaMax Discrete Output Modules C200MDL750 IC200MDL930 Discrete output modules send control signals to devices such as contactors indicator lamps and interposing relays that can also have two states Modules require a carrier base IC200CHSxxx IC200MDL940 Product Name VersaMax Discrete Output Module 24 VDC Positive Logic 0 5A per point 32 points VersaMax Discrete Output Module Relay 2 0 A per point Isolated Form A 8 points VersaMax Discrete Output Module Relay 2 0 A per point Isolated Form A 16 points Output Voltage 10 2 30 VDC 12 24 VDC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal 0 125 VDC 5 24 125 VDC nominal 0 265 VAC 47 63 Hz 120 240 VAC nominal Number of Points 32 8 16 Channel to Channel Isolation No Yes Yes Load Current per Point 0 5 A per point 2 0 A for 5 265 VAC 2 0 A for 5 30 VDC 0 2 A for 31 125 VDC 2 0 A for 5 265 VAC 2 0 A for 5 30 VDC 0 2 A for 31 125 VDC Input and Output Response Time On Off ms 0 2 1 0 10 0 10 0 10 0 10 0 Protection No internal fuses No internal fuses or snubbers No internal fuses or snubbers
125. t used maximum current used maximum current used maximum Dimensions W x H x D 49 mm 1 93 in x 49 mm 1 93 in x 49 mm 1 93 in x 49 mm 1 93 in x 133 4 mm 5 25 in x 133 4 mm 5 25 in x 133 4 mm 5 25 in x 133 4 mm 5 25 in x 39 mm 1 54 in 39 mm 1 54 in 39 mm 1 54 in 39 mm 1 54 in not including the not including the not including the not including the height of the carrier height of the carrier height of the carrier height of the carrier or the DIN Rail or the DIN Rail or the DIN Rail or the DIN Rail 180 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Power Supplies VersaMax Power Supply modules snap onto any VersaMax CPU or Network Interface Unit or onto a power supply booster carrier Each power supply can be used as the main power source for modules in the I O station or as a source of supplemental power for larger 1 0 applications IC200PWR201 IC200PWR202 IC200PWB001 Product Name 12 VDC Power Supply 12 VDC Power Supply with Expanded 3 3 VDC VersaMax Power Supply Booster Carrier Supplies power to all modules to the right of booster Requires power supply Input Voltage 9 6 15 VDC 12 VDC nominal 9 6 15 VDC 12 VDC nominal N A Output Voltage 5 VDC 3 3 VDC 5 VDC 3 3 VDC N A Extended Power No Yes N A Input Power 11W 11W N A Holdup Time 10 ms 10 ms N A Inrush Current 25 A at 12 VDC 30 A at 15 VDC 25 A at 12 VDC 30 A at 15 VDC N A Pr
126. ta Rate 9 6 Kbaud to 12 Mbaud 125 Kbaud 250 Kbaud 166 6Kbits second N A 500 Kbaud Network Topology Linear bus terminated Linear bus trunkline Tree Structure N A at both ends dropline power and signal Stubs are possible on the same network cable Transmission Media Shielded twisted pair cable Shielded dual twisted pair cable Rubber coated two wire cable N A Connector 9 pin D sub connector 5 pin open pluggable connector Box Style N A Number of Nodes N A Supports up to 40 Supports up to 31 slave devices slave devices N A User Diagnostic Data N A One presence bit per Display data N A slave device Power Consumption 460 mA maximum from 490 mA maximum from 350 mA maximum from N A 5 V output 5 mA from 5 V output 2 mA from 5 V output 3 3 V output 3 3 V output Dimensions W x H x D 110 mm 4 3 in x 66 8 mm 110 mm 4 3 in x 66 8 mm 110 mm 4 3 in x 66 8 mm 66 8 mm 2 63 in x 133 4 mm 2 63 in x 50 mm 1 956 in 2 63 in x 50 mm 1 956 in 2 63 in x 50 mm 1 956 in 5 25 in x 70 mm 2 75 in not including the height not including the height not including the height not including the height of the carrier or the of the carrier or the of the carrier or the of DIN Rail mating connectors mating connectors mating connectors www ge ip com GE Intelligent Platforms Control Systems Solutions 205 VersaMax Serial Communications The serial communications expansion module provides a Modbus Master port for a Genius NIU remote I O d
127. tions with up to 256 local I O or expanded systems of up to 4 096 I O points IC200CPU001 IC200CPU002 IC200CPU005 IC200CPUE05 Product Name VersaMax PLC CPU 32K Configurable Memory 2 Ports RS 232 and RS 485 VersaMax PLC CPU 42K Configurable Memory 2 Ports RS 232 and RS 485 VersaMax PLC CPU 128K Configurable User Memory 2 Ports RS 232 and RS 485 VersaMax PLC CPU 128K Configurable User Memory 2 Ports RS 232 and RS 485 10 MBIT Ethernet Port Supports EGD and SRTP 1 0 Discrete Points 2048 in 2048 out 2048 in 2048 out 2048 in 2048 out 2048 in 2048 out 1 0 Analog Words Configurable Configurable Configurable Configurable Registers Configurable Configurable Configurable Configurable Discrete Internal Bits 1024 points 1024 points 1024 points 1024 points Discrete Temporary Bits 256 points 256 points 256 points 256 points Global Discrete Bits 1280 points 1280 points 1280 points 1280 points Program Memory Configurable Configurable Configurable Configurable Boolean Execution Speed 1 8 ms K typical 1 8 ms K typical 0 8 ms K typical 0 8 ms K typical Floating Points Yes Yes Yes Yes Override Yes Yes Yes Yes Built in Communications SNP Slave RTU Master and Slave Serial I O SNP Slave RTU Master and Slave Serial 1 0 SNP Slave RTU Master and Slave Serial I O 10 MBIT Ethernet Port Slave RTU Master and Slave Serial 1 0 Type of Memo
128. ton 98 98 98 98 490 Amplifier Model IC800VMA102 IC800VMA102 IC800VMA202 IC800VMA202 IC800VMA302 248 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano VersaMotion Accessories Amplifier Connectors Motor Connectors ICB00VMACONCN1 CN11 0 Connector IC800VMMCONPO01 Motor Power Connector for 100 Watt to 750 Watt motors without brake IC800VMACONCN2 CN2 Encoder Connector IC800VMMCONP002 Motor Power Connector for 100 Watt to 750 Watt motors IC800VMACONCN3 CN3 Communication Connector with brake IC800VMACONACP AC Power Connector 100W to 1kW models only IC800VMMCONP003 Motor Power Connector for 1000 Watt or 2000 Watt motors with or without brake ICBOOVMACONMTRP_ Motor Power Connector 100W to 1kW models only i IC800VMMCONP004 Motor Power Connector for 3000 Watt motors with or IC800VMADBRO01 External Braking Resistor Connector 100W to 1kW models only j without brake IC800VMMCONE001 Encoder Connector for 100 Watt to 750 Watt motors IC800VMMCONE002 Encoder Connector for 1000 Watt and larger motors Motor Power Cables IC800VMCP030 Power Cable for 100 Watt to 750 Watt servo motor without brake 3 m 9 8 feet IC800VMCP050 Power Cable for 100 Watt to 750 Watt servo motor without brake 5 m 16 4 feet IC800VMCP100 Power Cable for 100 Watt to 750 Watt servo motor without brake 10 m 32 8 feet IC800VMCP200 Power Cable for
129. trol Voltage Relay Out 2 at 10 Amps 120 VAC 12 VDC Relay Out 24 VDC and 4 at 2 Amps Relay Maximum Resistive Load Rating 2 Amps at 24 VDC N A N A 2 Amps at 24 VDC N A and 240 VAC 10 Amp and 240 VAC at 24 VDC and 240 VAC Dimensions WxHxD mm 95x90x76 95x90x76 150x90x76 150x90x76 150x90x76 226 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Discrete Expansion Units The VersaMax Micro s modular design provides you with remarkable flexibility in a compact control The versatile Micro PLC can support up to four Expansion Units of any mix of discrete or analog IC200UEX222 IC200UEX212 IC200UEX211 IC200UEX209 IC200UEX210 Product Name 28 point 16 28 point 16 28 point 16 24 VDC In 28 point 16 120 28 point 16 24 VDC In 12 24 VDC In 12 Relay Out VAC In 12 Relay 24 VDC In 24 VDC Out with 12 Relay Out 120 240 VAC Out 2 outputs at 12 120 VAC Out ESCP 24 VDC 24 VDC Powered Powered 10 amp and 10 120 240 VAC Powered outputs at 2 amp Powered 120 240 VAC Powered Micro Type Restrictions N A N A N A N A N A Number of Discrete Inputs Outputs 16 In 12 Out 16 In 12 Out 16 In 12 Out 16 In 12 Out 16 In 12 Out Power Voltage 24 VDC 24 VDC 120 240 VAC 120 240 VAC 120 240 VAC Input Power Supply Rating 5 Watts 8 Watts 26 VA 16 VA 16 VA 24 VDC User Power for Sensors 200 mA 200 mA 200 mA 200 mA 200 mA Input Device Voltage 24 VDC 24 VDC 24 VDC 120
130. ts 16 analog in 8 analog out Physical I O Maximum 140 140 140 140 User Program Logic Memory Words 9K 9K 9K 9K Registers Words 2K 2K 2K 2K Analog Pots for Data Adjustment Yes 2 Yes 2 Yes 2 Yes 2 Serial Port Connector Type RJ 45 RS 232 port 1 and DB 15 RS 485 on port 2 RJ 45 RS 232 port 1 and DB 15 RS 485 on port 2 RJ 45 RS 232 port 1 and DB 15 RS 485 on port 2 RJ 45 RS 232 port 1 and DB 15 RS 485 on port 2 Protocols Port 1 SNP SNP X Breakless Port 2 SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read Port 1 SNP SNP X Breakless Port 2 SNP SNP X Breakless Port 1 SNP SNP X Breakless Port 2 SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read Port 1 SNP SNP X Breakless Port 2 SNP SNP X Breakless RTU Master and Slave 2 and 4 wire RTU Slave SNP Master Serial Read and Write and Write and Write and Write Power Voltage 120 240 VAC 120 240 VAC 24 VDC 24 VDC Input Power Supply Rating 16 VA 16 VA 5 Watts 5 Watts 24 VDC User Power for Sensors N A 200 mA 200 mA 200 mA Input Device Voltage 120 VAC 120 VAC 24 VDC 24 VDC Maximum Type A and B Counters N A N A 4 Type A and 1 Type B 4 Type A and 1 Type B 10Khz 16 bit 10Khz 16 bit Output Control Voltage 120 VAC R
131. ts 24 24 VDC Outputs 24 VDC Outputs IC200UEX364 24 VDC 40 Inputs 24 40 Inputs 24 24 VDC Outputs 24 VDC Outputs IC200UEX064 24 VDC 40 Inputs 24 40 Inputs 24 Relay Outputs Relay Outputs IC200UEX164 120 240 VAC 40 Inputs 24 40 Inputs 24 Relay Outputs Relay Outputs Micro 20 40 and 64 support only 222 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano Discrete Expansion Units The VersaMax Micro s modular design provides you with remarkable flexibility in a compact control The versatile Micro PLC can support up to four Expansion Units of any mix of discrete or analog IC200UEI08 IC200UEI016 IC200UEO008 IC200UEO016 IC200UEO108 IC200UEO116 Product Name 8 point 8 16 point 16 8 point 8 24VDC 16 point 16 24VDC 8point 8 24VDC 16 point 16 24 VDC 24 VDC In 24 VDC 24 VDC In 24 VDC Output with ESCP Output with ESCP Sink Output Sink Output 24 VDC Powered Powered Protection 24 VDC Protection 24 VDC Powered Powered Powered 24 VDC Powered Micro Type Restrictions N A N A N A N A N A N A Number of Discrete Inputs Outputs 8 In 16 In 8 Out 16 Out 8 Out 16 Out Power Voltage 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC Input Power Supply Rating 4 Watts 4 Watts 4 Watts 4 Watts 4 Watts 4 Watts 24 VDC User Power for Sensors 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA Input Device Voltage 24 VDC 24 VDC N A N A N A N A Output Control
132. ts of I O IC200PBI001 Product Name Genius Network Interface Unit Remote I O Profibus DP Network Interface Unit Slave Protocol Supported Genius Profibus DP Distance 1372 to 2286 meters 38 4 Kbaud supports a maximum of 16 devices 1067 to 1372 meters 76 8 Kbaud supports a maximum of 32 devices 609 to 1067 meters 153 6 Kbaud extended supports a maximum of 32 devices Less than 609 meters 153 6 Kbaud standard or 153 6 Kbaud extended supports a maximum of 32 devices 9 6Kbits 1 200 meters 19 2Kbits 1 200 meters 93 75Kbits 1 200 meters 187 5Kbits 600 meters 500Kbits 400 meters 1 5Mbits 200 meters 3Mbits 6Mbits 12Mbits 100 meters I O Discrete Points 1024 Inputs and 1024 Outputs 375 bytes maximum Up to 244 bytes of inputs or 244 bytes of outputs 1 0 Analog Words 64 Analog In and 64 Analog Out 375 bytes maximum Up to 244 bytes of inputs or 244 bytes of outputs 1 0 Data 128 bytes in and 128 out per bus scan 375 bytes maximum Up to 244 bytes of inputs or 244 bytes of outputs Network Topology Bus Linear bus terminated at both ends Stubs are possible Transmission Media Shielded twisted pair fiber optic external option Shielded twisted pair cable Connector Removable Connector 9 pin D sub connector User Diagnostic Data Yes 2 bytes of status control 5 bytes of standard Profibus diagnostics Number of Modules 8 per NIU
133. u can monitor change data view diagnostics force ON OFF and configure machine setup saving you time and increasing productivity 1 IC690PWR124 24 VDC 10 Amp Output Power and 120 230 VAC Input Power Power Supply 100 5V 1 IC200ACC003 EZ Program Store CPU RS485 Port Update Device www ge ip com GE Intelligent Platforms Control Systems Solutions 209 Notes 210 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Nano and Micro Introduction VersaMax Nano and Micro Controllers Don t let size fool you Although they are easy on valuable panel space the VersaMax Nano and Micro PLCs are big on features For high volume applications where cost and fast processor speeds are an issue the VersaMax Nano is the PLC of choice For additional functional ity the modular VersaMax Micro offers the features and the flexibility to match application needs in such industries as food processing chemicals packaging water and wastewater construction equipment and plastics Nano PLCs page 213 Micro PLCs pages 214 221 DataPanels Operator Interfaces page 234 pages 235 236 Communications Options For tight spaces the VersaMax Nano PLC is the perfect solution Thanks to its all in one construction installation is a breeze All you have to do is snap it onto a DIN rail or screw it into a panel With the VersaMax Nano you save on initial as well as life cycle costs The small footprint VersaM
134. uct Name Micro 64 40 24 VDC In 24 24 VDC Source Out 0 7 amps with ESCP protection 24 VDC Powered Micro 64 40 24 VDC In 24 24 VDC Sink Out 0 7 amps 24 VDC Powered Micro 64 40 24 VDC In 24 Relay Out 2 0 amps 120 240 VAC Powered Micro 64 40 24 VDC In 24 Relay Out 2 0 amps 24 VDC Powered Number of Discrete Inputs Outputs 40 In 24 Out Supports 4 Expansion Units 40 In 24 Out Supports 4 Expansion Units 40 In 24 Out Supports 4 Expansion Units 40 In 24 Out Supports 4 Expansion Units Number of Analog Inputs Outputs Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion units 16 analog in 8 analog out Supports up to 4 analog expansion units 16 analog in 8 analog out Physical I O Maximum 176 176 176 176 User Program Logic Memory Words 24K 24K 24K 24K Registers Words 32K 32K 32K 32K Analog Pots for Data Adjustment No No No No Serial Port Connector Type RJ 45 RS 232 port 1 and optional port 2 DB 15 RS 485 or RJ 45 RS 232 or USB or RJ 45 Ethernet 10 100 Mbit RJ 45 RS 232 port 1 and optional port 2 DB 15 RS 485 or RJ 45 RS 232 or USB or RJ 45 Ethernet 10 100 Mbit RJ 45 RS 232 port 1 and optional port 2 DB 15 RS 485 or RJ 45 RS 232 or USB or RJ 45 Ethernet 10 100 Mbit RJ 45 RS 232
135. umptions should be tracked to rei determine what power supply and how many power supplies may be required VersaMax Expansion Rack 1 4 DIN rail clips should be used to secure the VersaMax modules IC200ACC313 15M with any IC200ERM002 ERMs 5 A maximum of 8 carriers any combination of I O or communications can be 250M withiall EQO0ERMOOLERME ft iLi Bal fi connected directly to either an NIU or CPU Power Supply Booster base is not le II cm rote Ey 3 counted as a carrier CPUs and NIUs can be expanded beyond the 8 carriers IC200CBL601 VersaMax Expansion Rack 7 using the Bus Transmitter Expansion IC200ETM001 and up to 7 Expansion 602 615 P Ps Receiver Modules IC200ERMOOx for a total of 64 carrier modules Terminator Plug m st Install the Terminator Plug supplied with the Expansion Transmitter module into the lower port on the last Expansion Receiver Spare Terminator Plugs can be purchased separately as part number IC200ACC201 Qty 2 Examples of Typical Application Configuration for Controller Example application requiring 30 24 VDC inputs and 10 Relay outputs AC power supply Power Supply Current Required mA Qty Part Number Description 40 5 Vand 100 3 V IC200CPU001 VersaMax PLC CPU 32K Configurable Memory 2 Ports RS 232 and RS 485 IC200PWR101 VersaMax 120 240 VAC Power Supply 1 5 amps 5 V and 0 25 amps 3 3 V 50 5V IC200MDL650 VersaMax Discrete Input Module 24 VDC Positive L
136. us word Up to 128 bytes of outputs 2 byte control word 1024 bytes maximum both discrete and analog AI 128 channels AQ 128 channels 1 0 Data Up to 128 bytes of inputs 2 byte status word 256 Bytes of input output Analog input and Analog output Up to 128 bytes of outputs 2 byte control word Network Topology Linear bus trunkline dropline power and signal Network dependent on the same network cable Transmission Media Shielded dual twisted pair cable terminated at both ends Ethernet twisted pair Connector 5 pin open pluggable connector RJ 45 User Diagnostic Data 2 bytes of status control 4 Number of Modules 8 per NIU station 8 per NIU station Redundancy N A No 5V Backplane Current Consumption mA 160 175 3 3V Backplane Current Consumption mA 10 425 Dimensions W x H x D 133 4 mm 5 25 in x 85 9 mm 3 38 in not including the height of power supply 133 4 mm 5 25 in x 85 9 mm 3 38 in not including the height of power supply www ge ip com GE Intelligent Platforms Control Systems Solutions 203 VersaMax Remote I O Units IC200GB1001 A Remote I O Unit connects VersaMax I O modules to a host PLC or computer via a variety of networks which makes it easy to include VersaMax 1 0 in Genius Profibus DP DeviceNet or Ethernet installations Together the Remote I O Unit and its modules form an I O station capable of providing up to 256 poin
137. utputs 12 VDC Outputs IC200UEX013 12 VDC 8 Inputs 6 8 Inputs 6 Relay Outputs Relay Outputs IC200UEX014 24 VDC 8 Inputs 6 8 Inputs 6 24 VDC Outputs 24 VDC Outputs IC200UEX122 24 VDC 8 Inputs 6 8 Inputs 6 24 VDC Outputs 24 VDC Outputs with ESCP with ESCP IC200UEX012 24 VDC 8 Inputs 6 8 Inputs 6 Relay Outputs Relay Outputs IC200UEX011 120 240 VAC 8 Inputs 6 8 Inputs 6 Relay Outputs Relay Outputs IC200UEX009 120 240 VAC 8 Inputs 6 8 Inputs 6 8 Inputs 6 Relay Outputs Relay Outputs Relay Outputs 4 2 amps 4 2amps 4 2amps and 2 10 and 2 10 and 2 10 amps amps amps IC200UEX010 120 240 VAC 8 Inputs 6 AC 8 Inputs 6 AC Outputs Outputs IC200UEX215 12 VDC 16 Inputs 12 16 Inputs 12 12 VDC Outputs 12 VDC Outputs IC200UEX213 12 VDC 16 Inputs 12 8 Inputs 6 Relay Outputs Relay Outputs IC200UEX214 24 VDC 16 Inputs 12 16 Inputs 12 24 VDC Outputs 24 VDC Outputs IC200UEX222 24 VDC 16 Inputs 12 16 Inputs 12 24 VDC Outputs 24 VDC Outputs with ESCP with ESCP IC200UEX212 24 VDC 16 Inputs 12 16 Inputs 12 Relay Outputs Relay Outputs IC200UEX211 120 240 VAC 16 Inputs 12 16 Inputs 12 Relay Outputs Relay Outputs IC200UEX209 120 240 VAC 16 Inputs 12 16 Inputs 12 16 Inputs 12 Relay Outputs Relay Outputs Relay Outputs 10 2 amps 10 2amps 10 2 amps and 2 10 and 2 10 and 2 10 amps amps amps IC200UEX210 120 240 VAC 16 Inputs 12 16 Inputs 12 AC Outputs AC Outputs IC200UEX264 24 VDC 40 Inputs 24 40 Inpu
138. w Powerful Motion Functions s Windowing e Follower Mode A GoHome _____ Velocity JOGGING Enable Enable GO Enable Enable t Output Input HOME Output Mpat Axis 2 Axis ax ADO Le A Axis AX ADO Directia ime Enable gt Home Execute EX DN Done Forward EF AC Active Position 4 Enable A Acceleration ACC AC Active Velocity Velacity Backward E ER Error Go Home pulses sec og Velocity Deceleration DEC ER Error Acceleration ACC ES Go Home Velocity GHV E Error ID Ace bec Deceleration DEC WR Warning Time a WR Warning eau VEL Home Home Position Offset Time seconds Go Home With or without offset Jog Enable Configured Enable ee 1 Ginput Home Enable_ FINDHOME Enable Axis Direction Input sis I Move 1 Move 2 Move3 Move 4 Axis AX ADO era A Axis AX ADO Direction 1 Home Output Execute EX DN Done Execute EX DN L Done D Number of td i Profiles NP ac L active 3 parame MP ac L active T a gt Axis Direction l ADi ER Error Final Home Fav ER Error j 5 Velocity parameters MP G TE 3 Home _ po El Error ID Offset Distance in Pulse Counts re WR Warning oe PIRA ADI WR j Warning Blended Move Up to 4 Moves Find Home 212 GE Intelligent Platforms Control Systems Solutions www ge ip com VersaMax Micro amp Nano cE PUT RPE ETIE Nano 10 PLCs The palm sized VersaMax Nano PLC is highly compact
Download Pdf Manuals
Related Search
Brochure brochure brochure printing brochure template brochure maker brochure printing near me brochure meaning brochure examples brochure design brochure holder brochure templates free brochure stand brochure paper brochure size brochure mockup brochure canva brochure ai brochure mockup free brochure online brochure png brochure 3 fold brochure menu brochure in english brochure vector brochure vs leaflet brochure meaning in english
Related Contents
3 - Shavlik Help Center STONSHIELD SLT 1 - Llanos Copyright © All rights reserved.
Failed to retrieve file