1. 00 mA 7 One telephone line 1 PDF ee ei pdfFactory Pro iAheAsGy lt 2 www fineprint co 4 System installation A Main unit 1 Connect one terminal of telephone line to the main unit and the other terminal to the telephone 2 Put DC terminal of enclosed adapter into DC jack of the main unit and connect AC plug to AC pow er supply 3 Load 4X AAA Size alkaline batteries orNI Mh batteries at the back of the main unit for spare power supply 4 ltis best to put the mainunit in a hidden place to avoid the intruder s damage 5 W hen the left switch onthe main unitis turn to OFF the main unit s poweris shut off whentheswitchis turn to ON the indicator light of the main unitis onwithan remind sound which means the main unit power is on now ea screen ON OFF DC plug telephone wire inlet microphone B Wireless siren w ith light 1 indoor Load 3x LR6 alkaline batteries and putit in an obvious place inside the house LED light er FA 2 outdoor Loose the screws load 4x LR6 alkaline batteries and put it inan Obvious Place outside the house a 0 aa m D C Magnet sensor It consists of magnetic bar and sensor Stick the magnetic bar and sensor on the door window and door frame w indow frame w ith double side adhesive tape Align the magnetic bar and sensor and pay attention that the distance betw een them is not more than 10mm D Infrared sensor Load 3 p
2. CONTENTS lUsage nts 1 2 Feature 42 2 2 ett 1 3 Accessories gt gt oum 1 4 System installation en 2 5 Operationinstruction ea 5 6 Additional accessories uan 6 7 Technicaldata uen 7 8 Diagram nee 8 PDF XE pdfFactory Pro WHAIA www fineprint cn Intelligent Auto Dialed Alarm System dial automatically the number saved by householder MODEL RL 0503CD ig ag CE Fe USER MANUAL Intelligent Auto Dialed Alarm System dial automatically the number saved by householder RL 0503CD USER MANUAL 1 Usage Ideal for house company warehouse etc where anti theft is needed The system will alarm sharply when someone intrudes illegally in arms status meanwhile 6 groups of telephone numbers stored in the main unit will be dialed automatically 2 Feature e Compared with other products this system is easier to operate e Magnetic code controller is equipped to arm the system easily When alarm is activated the host can enter correct passw ord within the limited time to disarm the system e Settings and stored data will not be lost after pow er failure e Up to 38 sensors canbe added to this system e Simple installation and usage 3 Accessories 1 One main unit 2 Tw o wireless siren with light indoor amp outdoor 3 One infrared sensor with bracket 4 Tw o magnet sensors enclosed 3 XLR44 alkaline batteries per sensor 5 One magnetic code controller 6 One adapter 9V 3
3. assword is 0123 F Operation Switchonthe main unit load batteries for allaccessories Operation begins when NO SAVE is show n inthe main unit 1 Record Press button REC and REC will be shown in the screen Release the hand when indicating sound is heard to begin the record The longest time for record is 10 seconds Record is stopped when indicating soundis heard The record willbe heard fromthe alarm telephone when system is activated 2 Set alarm telephone numbers Press to set alarm telephone numbers and they are shown inthe screen Press andthe numbers will disappear from thescreen which means the numbers have been storedin the system Forinstance if 13501234567 is an alarm number press 13501234567 and then this numberis storedin the system W hen onenumber is set a serialnumber willbe shown inthe main unit There are 6 groups of numbers maximally These six numbers will be dialed automatically when system is activated as perthe serial number from 1 to 6 3 Cancel the alarm number Press and then indicating soundw illbe heard to identify thatthe set six alarm numbers have been cancelled 4 Lock amp unlock the keypad Press button LOCK to lock the keypad press button LOCK tw otimes to unlock the keypad 5 Operation instruction a Arm press ARM on magnetic code controller one indicating sound from the main unit and wireless siren will be heard separately and SAVE will be shown in the screen Thesystem will be arme
4. d 30 seconds later The alarm numbers will be dialed automatically when someone intrudes illegally from the window ordoorwith magnet sensor or infrared sensor or enters the working range of infrared sensor if system is armed Record will be heard Wireless siren will alarm for 25 seconds with flashing light Switch the magnet sensorRF ALARM it willalso alarm 2 seconds after alarm from Wireless siren will light to frighten away the thief b Emergency press ALARM of magnetic code controller to arm the system for emergency The set six numbers will be dialed automatically as per serialnumber from 1 to 6 Wireless siren will alarm with flas hing light 5 PDF Pear pdfFactory Pro iAAheAsey 2 www fineprint co c Answer the telephone hang up the telephone or mobile and then other alarm numbers will be dialed continuously after one finishes answ ering the telephone and mobile and hearing the record If there is no need to dial the other alarm numbers press d M onitor the site press to monitor the site The longest time is two minutes Press to stop the dial and monitor e Disarm the system Enter password to disarm the main unit and wireless siren meanwhile indicating sound from them will be heard separately f Replace the battery Lower power supply indicating lights of Wireless siren and infrared sensor will work if power is not enough Please kindly replace the batteries when LED light of infrared sensor is yellow and LED light of
5. ieces of AAA alkaline batteries Put the adjustable bracket in a needed place and hang the infrared sensor on it Pay attention to avoid the direct sunshine do not face the glass window do not face the heat amp cold air vent or heat amp cold resource do not face something that swing easily The best height for installation is 1 0m to 1 5m Adjust the angle for best performance PDF Bear pdfFactory Pro WHARA www fineprint co KK J g 2 oe a se ae en oc a an r 73 Alarm Doors ae ao ag Bae Ba O aoc sas pee ED 1 E Magnetic code controller It consists of magnetic bar and controller sensor Load 3 pieces of AAA alkaline batteries stick the magnetic bar on the door frame with double side adhesive tape and fix the controller sensor on the door with screws Align the magnetic barand sensor and pay attention thatthe distance between them should be within 10mm Press ARM button the system will be armed 30seconds later If someone intrudes illegally from the doorwiththe magnetic code controller it will be activated instantly The system will be disarmed if someone enters the code in 30 seconds Arm button 1 Press ARM once to arm the system after 30 seconds 2 Press ARM continuously itwill enter code amendment mode 3 seconds later Press four digit new code then press ARM again to exit Alarm button To activate the system for emergency Number keys To set the code Initial p
6. urrent lt 5mA Transmission frequency 433 5MHZ 434M HZ Transmission distance gt 50m open area Wireless siren with light indoor e Power volts DC4 5V LR6x3 e Standby current lt 600uA Alarm current lt 170mA Alarm volume gt 95 dB within 0 5m Receive frequency 433 5MHZ 434M HZ Low voltage indication lt 3 1V 0 1V Wireless siren with light outdoor e Power volts DC6V LR6x4 e Standby current lt 650uA e Alarm current lt 200mA Alarm volume gt 105 dB within 0 5m e Receive frequency 433 5MHZ 434M HZ Low voltage indication lt 3 6V 0 1V PDF ete pdfFactory Pro WHARA www fineprint co 8 Diagram magnet sensor yy infrared sensor telephone line z M agnetic code controller W ireless siren with light main unit telephone telephone mobile phone alarm station
7. wireless siren flashes every five seconds 6 Additional accessories Load the batteries for needed accessories Press CODE buttons of the main unit and wireless siren one indicating sound from them will be heard If magnet sensor is added switch it RF move magnetic bar and sensor close then separate them more than 10mm if infrared sensor is added face it to the human until indicating light turns on If magnetic code controller is added press ALARM During each operation one indicating sound from the main unit and wireless siren will be heard separately Two indicating sounds from them will be heard 40 seconds after operation is finished which means that the added accessories is in working status right now 7 Technical data M ain unit e Input voltage DC6V 9V e Working current lt 12 m A e Receive frequency 433 5M HZ 434M HZ Infrared sensor e Input volts DC4 5V AAAx3 e Standby current lt 0 1mA e Transmission current lt 8mA e Transmission frequency 433 5 M HZ 434M HZ Transmission distance gt 50m open area Inductive distance gt 5m open area Low voltage indication lt 3 1V 0 1V Magnet sensor e Input volts DC4 5V LR44x3 e Standby current lt 10 uA Transmission current lt 8mA Transmission frequency 433 5M HZ 434M HZ e Transmission distance gt 50m open area Magnetic code controller e Input volts DC4 5V AAAx3 e Standby current lt 10uA e Transmission c