Home
INTERCEPT V.5 USER MANUAL - Coastal Environmental Systems
Contents
1. Next choose the speed or baud rate used by the station by choosing the correct speed from the drop down menu next to the label Baud Rate Some common settings are 1200 4800 and 9600 TCP IP To set up TCP IP communications you must enter the IP address of the station in the box labeled IP Address URL Enter the correct Port Number for the station in the Port box MODEM A data modem is usually assigned to a serial port Enter the phone number for the station in the Phone Number box In the Timeout box enter the number of seconds INTERCEPT will wait for the station to answer before timing out Enter the Serial Port number in the box labeled Serial Port COM and choose the correct Baud Rate from the drop down menu When you have set the Communications properties for a new station click Next and the Data Retrieval Pane will replace the Communications pane Data Retrieval Use the Data Retrieval pane to configure how often the station Sends data and other properties associated with the timing of data retrieval The Data Interval is either how often the station sends data or how often it should be polled for data in seconds If the station is polled select the Polled Station check box You can then enter the additional parameters that should be set for a polled station e Initial Offset The Initial Offset determines how many seconds into the polling interval this specific station should be polled for data This allows you to
2. Enter the Value to compare the selected data element against using the selected operator 7 Click Add Condition button At this point the alert criteria will be added to the Alert Conditions To add more conditions to the alert select AND or OR and then create another condition following steps 3 through 6 above When AND is selected an alert will be generated only when all conditions defined are true An AND could be used to check for wind chill by combining temperature and wind speed checks When OR is selected an alert will be generated when any of the alert conditions are met An OR could be used to test for a cross wind from either direction by checking for a wind direction shift from the prevailing wind in either direction 8 When all the alert conditions have been created enter an Alert ID in the Alert Settings Panel 9 Enter a more detailed description of the alert in the Alert Text field This will display in the ticker when the alert is triggered 10 Optional The alert will apply to all stations by default You can limit the alert to a specific station by checking the Apply to Specific Station checkbox then selecting the station from the drop down menu 11 Optional If you wish a sound to play when the alert condition is triggered check the Alert Sound checkbox Then select a sound file from the drop down menu 12 Optional Pick foreground and background colors for the display of the data elements in the
3. GUI Foreground color is the color of the text Background color is the background color of the cell displaying the data 13 Optional If you want the alert to blink check the Blink Effect box 14 To save the alert click Save Alert When the alert has been successfully registered at the server the ticker will display a confirmation message 5 9 Groups Use the Groups bar of the Data Display accordion to create station groups and assign station views to groups To create a new group click the New Group button in the upper left of the pane An empty group will open at the end of the groups Click the button in the upper right hand corner of the new group and enter the group name in the box in place of the text You can then add views to the group by selecting one from the Views list and dragging it to the group box CES will have configured INTERCEPT so that there is a Weather Summary view a Wind Dials view and a Station view for each station A view can be assigned to more than one group CES will assign the Weather Summary to all groups for example 6 MAPS 6 1 Map Display The Map view is an optional perspective that displays a map provided for a specific INTERCEPT installation Each of the stations is shown on the map as a circular icon Clicking on one of the station icons loads the data for the station into a pane to the right of the map For more information on this option contact Coastal Environmental System
4. station group will be displayed You can customize your default group using the User Profile option in the File Menu When ever you login the display is set to show your default group In the upper right hand corner of the window beneath the perspective buttons is the group selection drop down Use this drop down to change which group 15 displayed if you have more than one group At the bottom of the screen is a display field containing the most recent status or alert condition This is also where the client displays information about its session with the server For example when you login the message Welcome username is displayed to show that you are logged in and connected to the server correctly These entries begin with date and time followed by the message Entries related to specific stations show the date and time followed by a station ID and then the relevant message text The test for alarm conditions is determined by CES Text for alert conditions is set when you create alerts in the Maintenance perspective To the right of the status field is an Expand button Clicking this opens a window with the last fifty messages displayed in the status field Additionally alarm conditions are logged in the Maintenance log and Alert conditions to the Alerts log 4 2 Station Groups and Navigation The Observer perspective has an additional control on the data display to facilitate navigation between stations and station groups The station
5. tabs displayed by default are those whose stations are part of the default group chosen in user preferences Navigation to stations in other groups is done using group selection drop down in the upper right hand corner of the window just beneath the perspective buttons You can select a different group from the drop down and it will replace the current group Since all groups display the Station Summary pane that will be the selected tab when you switch groups 4 3 Weather Summary The Weather Summary pane is the default Observer screen The weather summary provides a tabular view of all the data from all of the stations When the weather summary is the active screen the Weather Summary tab the left most tab is highlighted Stations are organized into groups on the Weather Summary pane By default all groups will be opened Each group can be closed or re opened by clicking on the arrow to the left of the group name and folder icon The Weather Summary uses the short labels for the data elements if these have been created Otherwise it will use the input data labels Each row of the table begins with the timestamp and station ID Alert conditions are displayed on the Station Summary When alert conditions exist the individual table cell containing the data element whose value matches the alert condition will be highlighted in the alert color 4 4 Wind Dials The Wind Dials tab displays one wind dial for each of the stations This provide
6. the address for your local mail server Support Email Address The email address of the person or persons supplying support for questions and problems regarding INTERCEPT After you change any of the settings on this pane click Save to make those changes permanent To reset changes that you have made before saving click Cancel 5 3 Data Collection The Data Collection screen contains an accordion style control The control accesses the following panels e Stations where you can add edit and change communications settings for stations Data Elements where you can modify the labels used for data that comes in from the stations e Diagnostics where you can set the display text associated with the ZENO bit messages 5 4 Stations The Stations section of the Data Collection accordion is used to configure a station CES will define your stations before sending you the software The installation instructions tell you how to add your custom settings to the software when you install it Therefore when you enter this screen it will already display a list of your stations There are three steps to configure a station The first step is Basic Settings These are properties that identify the station The second step is Communications where you configure station communications and associated properties The final step is Data Retrieval where you configure the data retrieval interval When adding a new station required properties for ea
7. value 5 unit gt lt reading label RLIM_status value CONNECTED unit gt lt reading label Active_Heading value 0 unit gt lt station gt lt station id 3 timestamp 2009 04 28 11 05 00 PDT gt lt reading label 1 Minute Ambient Light value M unit cd m 42 gt lt reading label 1 Minute Visibility value 678 unit m gt lt reading label AV_VIS_BIT value 00 unit hex gt lt reading label 10 Minute Visibility value 679 unit m gt lt reading label zeno_status value CONNECTED unit gt lt reading label AV_BIT value 0 unit hex gt lt station gt lt station id 2 timestamp 2009 04 28 11 05 00 PDT gt lt reading label 1 Minute Ambient Light value M unit cd m 42 gt lt reading label 1 Minute Visibility value 1091 unit m gt lt reading label AV_VIS_BIT value 00 unit hex gt lt reading label 10 Minute Visibility value 1077 unit m gt lt reading label zeno_status value CONNECTED unit gt lt reading label AV_BIT value 0 unit hex gt lt station gt lt station id 1 timestamp 2009 04 28 11 05 00 gt lt reading label 1 Minute Ambient Light value 20000 unit cd m 2 gt lt reading label 1 Minute Visibility value 11 unit m gt lt reading label AV_VIS_BIT value 00 unit hex gt lt reading label 10 Minute Visibility value 9 unit m gt lt reading label zeno_status value CO
8. 1 User Menu The User menu contains two entries Log Out and User Profile You use Log Out to exit INTERCEPT This disconnects the client from the server and takes you back to the login screen On the User Profile screen you can change your profile display settings and password To change contact information or the display settings make the appropriate edits in the fields on the left hand side of the window and then click on Submit Profile Changes If INTERCEPT is configured with more than one group you can select which group of stations should be displayed when you log in The Default View drop down contains a list of all of the station groups The one you select will always be set as the current one when you log in to INTERCEPT For Aviation systems there aren t groups so this drop down 15 empty The default display uses the Day skin dark text on light background There is a Night skin with light text on a dark background that you can switch to using the Skin drop down To change your password enter a new password in the field on the right hand side of the window and click Submit New Password The User Profile window will stay open until you click on the x in the upper right hand corner to close it 3 2 Records You use the Records menu to access the data log files Users with Maintenance permission can also manage Archive files using this menu Log files are dated files written by INTERCEPT to a log folder in the IN
9. ENO ID for the station and will be set by CES How the station connects to the computer running INTERCEPT Serial port TCP IP or modem e The configuration information for the connection The data interval for the station Whether the station is polled and if so the polling interval It is a good idea to do the basic configuration for one station and confirm that it is communicating correctly with INTERCEPT before configuring the display You can do this by following the instructions in Basic Settings under section 5 4 Stations Once you have a station configured and enabled INTERCEPT will begin receiving data from the station immediately You can verify that the data is coming in by switching to the Observer perspective Using either the summary screen or the station tab for the station review the data Note that for stations with a low update frequency you may have to wait for the next data interval to complete before you will see data 2 USER INTERFACE 2 1 User Roles INTERCEPT supports five user roles Four of the roles provide access to various functions in the application through the user interface The fifth role external user provides access to an xml data feed How an external user accesses the feed is described in the External User section The four roles with perspectives in the user interface are Observer a user who views the weather data e Maintenance a user who configures the systems and re
10. INTERCEPT V s USER MANUAL December 5 2011 1 Introduction 1 1 1 2 1 3 Document Conventions pp pg 3 ET pg 4 Administrator Log pp pg 5 INTERCEPT Station Configuration eee eee ees pg 6 2 User Interface 2 1 22 3 Menus 3 1 3 2 3 3 3 4 3 5 4 Observer 41 42 43 44 4 5 Fleege eege dE ee pg 7 RE pg 7 User Meng de E EENS SEENEN ee Ee pg 10 EES ee pg 10 Data EE pg 11 Archive EE pg 12 eevee pg 14 Obs rver Perspective os ke Ee pg 15 Station Groups 20 2 2 pg 16 Weather Summary e Ke KANNER EEN NEEN nee ese pg 16 AER et pg 17 Stat s TEE pg 17 5 Maintenance 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 6 Maps 6 1 SLALOM SALI EE pg 18 ues pg 18 Data COUCCHOM EE pg 19 e pg 19 Data GE pg 21 EE gedet pg 22 IR RRE EE pg 22 EE pg 22 VE pg 23 Konse ge eege gd EE eege eech pg 25 7 Administrator 7 1 User Administration pp pg 26 8 External Data 8 1 External Dats Peed cca eco tiles tty pg 28 Appendix A Troubleshooting 1 INTRODUCTION Coastal Environmental System s INTERCEPT application connects to one or more stations to retrieve weather data INTERCEPT is installed on a PC that is connected to the stations either directly or over a radio or phone modem link A station is aZENO WEATHERPAK with senso
11. NNECTED unit gt lt reading label AV_BIT value 0 unit hex gt lt station gt lt readings gt Appendix Troubleshooting 1 I am unable to see all of the selection boxes in the Maintenance screens A Check the resolution of your computer monitor INTERCEPT may be best viewed on a display with resolution set to a minimum of 1280 x 1024
12. TERCEPT installation folder Archive files are data files that you can customize to export data into other systems Archive files are written to a path you specify The default location is also within the INTERCEPT installation folder Log and Archive files are written folders on disk Log files are always written to a log folder within the INTERCEPT installation folder The folders are organized into a tree structure that includes both the station ID and the date in the path You can request that CES configure either the station ID or date be the highest level entry The default is to begin with the date Depending on this setting the path to each data file is either YYYY MM DD Station ID or Station ID Y Y Y Y MM DD For hourly files the file name has the hour in the form HH added to the end of the file name before the extension where HH is the two digit hour using the 24 hour clock To view log files select the View Logs entry in the Records menu A log view window will open on the top of the display Since log files are written for each station you begin by selecting a station in the Select a Station drop down Then enter a date into the calendar entry Log Dates The default date is the current day Click the Get Logs button and a list of available logs for that station and date will be displayed in the list area Click on the log that you wish to view The selected log will open in the pane next to the list For more informatio
13. This organization allows INTERCEPT to provide access to more data than would fit onto one screen INTERCEPT tabs available in the Observer screen may include any of the following tabs depending on how the system has been configured e Weather Summary tab containing the data for all stations presented in a tabular format Wind Dial tab showing the wind dials for all stations e Station tab for each station or if the stations are grouped for each station in the currently selected group Beneath the data display is a status ticker The status ticker is shown for all perspectives and shows the most recent status alarm and alert information for the stations The ticker also provides information on communications between the client and the server If your client cannot communicate with the server for example a message indicating that will be displayed in the ticker At the right hand side of the ticker is an Expand button Clicking on this opens a Status and Alerts window that displays the last fifty alarm and alert conditions generated by the application Several tabs in the Maintenance perspective contain accordion style controls This style of control consists of a set of collapsible panels only one of which can be open at a time The accordion headers are stacked vertically and the content area opens beneath the header Clicking on a header opens the corresponding content area and closes the one that is open 3 MENUS 3
14. aintenance logs of all system status information and alert logs The set of log files generated is determined by the type of INTERCEPT system and the stations connected Perspective All of the content available to a specific user role It includes all the content that can be reached through any tab or button on the screen not just the visible content Role Specific way in which a user can interact with INTERCEPT Observers primarily view data Maintenance users can configure settings related to the stations communication with the stations and how the data is displayed for Observers of the data Administrators manage user accounts A particular user can be assigned to one or more roles though only one role s perspective is active at a time Skin Set of colors and graphics applied to the screen Changing the skin modifies the aesthetics of the screen without changing the content or position of any elements Skins are also sometimes called themes View Display as seen by a particular user perspective or role For the Observer and Maintenance perspective the view does not contain all the content available to the user since the content is contained in tabs each presenting a subset of the entire content available in that perspective 1 2 Getting Started INTERCEPT is delivered on a CD containing an installer and custom configuration files created at CES The configuration files are installed along with the application Instructions for i
15. and Delete respectively The later two are only enabled when you have selected an entry in the list Creating an archive is a two step process First you define the data you want saved in the archive file and the order Next you specify the properties associated with the archive file Selecting either New or Edit will take you to the archive format screen For New archives this screen defaults to the same groups defined for the Observer station layout Only the actual data within the groups is saved to the archive file The group construct 15 used to order the file The archive format screen is similar to the screen used to modify the station layout You can create as many groups as you like and then drag data elements from the list on the left into groups You can also reorder elements within groups and reorder groups by simply dragging elements to their new location You can delete a group by selecting the box in the upper right hand corner of the group box and selecting the Delete option in the drop down that opens You can name a group by selecting the box in the upper right hand corner of the group and then entering a name in the text field in the first row of the drop down When you have finished defining the archive format click Next in the lower right hand corner of the screen The screen where you set the file related properties will replace the archive format screen You can set five file related properties e File Name this is th
16. ata from stations connected to INTERCEPT The Observer perspective has two types of views those that show data for all of the stations and those that show data for just one station The views are presented as a set of tabs spanning the display from left to right Two default views are configured by CES before your systems are shipped These are e Weather Summary Fixed Station The Weather Summary tab displays the data from all the configured stations in a tabular format CES configures this view and always makes it the first left most tab in the Observer perspective A Station Tab is a detailed display of the data for one station There is a Station Tab displayed for each station in the currently selected group The station tabs are customized for your specific data set at CES before the system is shipped Data is displayed in labeled text boxes by data type Typical data groups are Wind Temperature and Humidity Pressure Precipitation The Wind Dial may also be included on the station display The Wind Dials tab displays a dial widget for each station CES configures this view and makes it the second tab for each group in the Observer perspective For more information on the three types of Observer views and how you can customize them further see the Layout topic in the Maintenance section Section 5 of this manual If you have more than one group of stations defined then only the station tabs for the currently selected
17. ch step must be set before you can advance to the next step Icons in the lower left hand corner indicate which sections have been completed successfully The Stations section of the accordion opens to a list box containing the names of existing stations To add a new station click the Add Station button beneath the list To edit an existing station click the station name in the list box and then click the Edit button The Basic Settings pane will replace the Stations pane Basic Settings Basic settings are station properties that define the station They are e Station ID for the station you are configuring The Station ID for your stations at CES For Zeno3200 and Weatherpak stations the Station ID is shown as ZENO ID For Aviation stations it is shown as FDCU ID e Name of the station e Optionally enter the Latitude and Longitude for the station e Time Zone that the station is set to Note that CES sets stations to UTC by default The Configuration to use Each station has been configured to send data in a specific format to INTERCEPT The available configurations are defined in a properties file that matches the correct configuration with the settings of your station This will be set at CES If the configuration of your station is changed then the Configuration settings in INTERCEPT must be changed to match it When INTERCEPT is installed it will contain a file defining the configuration of your station plus the common
18. chive Files Archive files are data files created to your specification You specify the data to include the order and which of three field delimiters to use The first line of the file contains the short labels for the data elements Each subsequent row contains the data values for one reading from the station The delimiter you select separates the data elements You can also specify hourly or daily archives Maintenance Users can define archive files using the Manage Archives option of the Records menu The Archive Management pane opens with a list of existing archives The list contains the enabled status and path for the archive Note that the path is a combination of the file path to the root of the archives and the base filename So a path with value C Program Files Coastal Environmental Systems INTERCEPT1 11 15 archives Winds will result in archives stored in C Program Files Coastal Environmental Systems INTERCEPT1 11 15 archives with subfolders for each station Within the station folders archives are further arranged by date in the structure yyyy mm dd The day folder will contain one file named Winds csv if daily archives have been selected If you select hourly files then there will be one file for each hour of the day with the name Windshh csv where hh is a two digit identifier for the hour using the 24 hour clock Beneath the list of archives are three buttons These are to add a New Archive Edit Archive
19. configurations used If your station is changed CES will either tell you which new Configuration to set for the station or send you a new configuration file with instructions on how to install it Stale Data seconds indicates how long data stays valid on the GUI You can set the Basic Settings immediately if you are adding a new station When you are done click Next to continue on to the Communications pane which will replace the Basic Settings Pane If you have not set one of the required properties the field for that property will have a warning next to it in a red box and the screen will not advance If you are editing an existing station the Basic Settings pane will open with the data for that station populating the fields Communications INTERCEPT receives data from each station using the method defined in the Communications pane This pane opens with just a drop down menu labeled Type Select the correct communications type from those available in the menu Serial TCP IP or modem The fields for configuring that communication type are displayed beneath the menu when the type is selected Serial Communication You must set both properties to configure a Serial Port The first is the number of the Serial Port through which the station is connected to the server Enter the Serial Port number in the box next to the label Serial Port COM For example if the station was connected through Com 1 on the server you would enter 1
20. e base file name for the archive e File Enabled enable disable file write The default setting is Enable checked e File frequency you can set archives to write daily or hourly The hourly setting is used when data is updated frequently and the archive file size might get too large Delimiter you can select Comma Pipe or Tab as the delimiter between data elements e File Output Path the default location is a folder called archive within the INTERCEPT installation folder When you are done configuring the archive file select Save in the lower right hand corner If you exit Archive Management without saving you will lose your changes You can also Cancel at any time during either step of the process To exit the Archive Manager click on the x in the upper right hand corner 3 5 Help The Help menu provides access to information about INTERCEPT The menu options are Contents and About Selecting Contents from the Help menu opens a window displaying application help The window is split into two sections vertically On the left side is a table of contents and the right side displays the selected help contents Selecting About from the Help menu opens a window that displays the version number and copyright information for INTERCEPT You close the box by clicking on the x in the upper right hand corner 4 OBSERVER 4 1 Observer The Observer perspective is the primary data display for INTERCEPT It presents d
21. hat the station has been added and that INTERCEPT is receiving data by switching to the Observer perspective The station will appear in the Station Summary tab If the connection was successful there will be data in the summary screen as soon as it is received from the station This will be dependent on how often the station sends data or is polled 5 5 Data Elements Data Elements is used to modify the default labels and display units for data reported in INTERCEPT The list of data elements in the table is populated with all the data elements reported by stations of the type selected The first column labeled Data Element lists all the data obtained from the station using the data labels from the Station Types file This is the only entry in the column that can t be changed The third column labeled Label defaults to the data element label and is used in the station Observer screen This can be changed by selecting the label and then typing the new label in its place The second column is an optional Short Label When this is set it is used in the Summary screen in place of the longer labels It is also used in the Alerts creation panel 5 6 Diagnostics This tab defines the text that is displayed for the various BIT codes from the ZENO This is configured by Coastal and BIT errors are restricted to the Maintenance screen and logs 5 7 Data Display The Data Display tab on the Maintenance perspective provides access to the cont
22. mail user roles and defaults can be changed Clicking the Save Changes button saves the changes To change the user s password use the Change User Password form Enter the new password and click Submit To lock the account select the Lock Account entry in the Account Lock form and then click Submit Deleting a User Account To delete a user account 1 Select the user name for the account in the list box 2 Select the Delete User option in the Delete User form 3 Click Submit in the Delete User box The Edit User form will be cleared of account information the user name is removed from the list box and the following message will display in the ticker User deleted 8 External Data 8 1 External Data Feed The external data feed is an XML feed It contains the latest data from each station INTERCEPT is pre configured with one XML data feed account with Username feed Password coastal You can create a different account in the Administrator perspective The feed is accessed through the URL http hostname intercept wxws reading all username feed amp password coastal where hostname is the URL for your server where INTERCEPT is installed Below is a sample of the data from an RVR system with an RLIM and three stations with Visibility sensors lt readings gt lt station id RLIM timestamp 2009 04 28 11 05 43 PDT gt lt reading label RLIM_Edge value 5 unit gt lt reading label RLIM_Center
23. make sure that different stations are polled at a different time during the interval This is particularly useful when more than one station is polled through the same device e Poll Timeout The Poll Timeout indicated how many seconds to let a poll attempt continue without response before terminating Number of Retries Number of Retries indicates how many times Intercept should attempt to reach a station during one polling interval e Samples in Request Samples in Request indicates how many samples will be returned for each poll when performing DA polling e Polling Method DA returns all the data since the last successful poll Intercept requests the number of samples set in the Samples in Request field for each request and continues to poll until it has caught up DL requests return only the most recent data sample You can schedule exact times on the hour when you wish the poll to take place After selecting Polled Station select Use Scheduled Polling Set the offset and the interval The sum of these two numbers will give you the time on the hour when the poll will occur For example an offset of 1 and an interval of 30 will cause the poll to occur at 1 and 31 minutes of the hour When you are done setting up the Data Retrieval for a new station click Save INTERCEPT will save the station configuration to the server Note that it may take a moment for the information to register with the server You can verify t
24. n on the data logs see the Data Log section of this manual Once you have opened a log you can slide the log picker closed by grabbing the slider icon and pulling it to the left hand side of the pane The slider icon 15 three parallel lines in the middle of the right hand side of the selection column To create or manage an archive file use the Manage Archives selection in the Records menu 3 3 Data Log The Data log is one of the standard log files created by INTERCEPT and is accessed through the View Logs option of the Records menu The Data log records all the data received from the station in daily log files Each record is displayed on one line of the display beginning with the date and time the data was received followed by the data The data is arranged in the same order as the list widgets on the Station screen Each list widget is displayed as a group of columns one for each element in the widget The columns are labeled with the short labels To the right of the group label is an arrow pointing to the label Clicking on this collapses the group You can use this feature when there are specific data groups that you are interested in seeing on the screen without scrolling The arrow representing the group changes to point in the opposite direction Clicking on it will expand the group You can use this feature to narrow the data view when you are interested in a subset of the data and wish to view it without scrolling 3 4 Ar
25. nstalling INTERCEPT are included on the CD CES creates your custom configuration while testing your stations Each station is added to INTERCEPT and the communication settings are configured according to your instructions The Observer screen layouts are configured to display the data coming from your stations If you have more than a few stations then the stations may be organized into groups These configuration settings are included in the version of the software when you install it on your own server In some cases INTERCEPT will begin receiving data from your stations as soon as it starts running and the stations are connected In other cases you may have to adjust some communication settings See the section on Data Collection for instructions on configuring stations INTERCEPT comes with default users assigned for each of the User roles Additional users can be added using the Administrator screen The default Administrator log in is ID admin PW coastal 1 3 INTERCEPT Station Configuration Once INTERCEPT is installed you can configure your station or stations Coastal configures systems before shipping based on information that you provide You may need to adjust certain properties such as the communications settings Also INTERCEPT may be best viewed on a display with resolution set to a minimum of 1280 x 1024 You need the following information to configure a station The station ID This is the unique Z
26. nterval This interval the INTERCEPT Client Polling Interval is set on the Settings tab of the Maintenance UI The default is thirty seconds If your stations are being polled less frequently you can increase this time The UI is arranged into three sections The menu bar runs along the top of the screen The large section of the screen beneath the menu bar is the data area The content of the data areas is determined by the current perspective A status ticker runs across the bottom of the display The left side of the menu bar contains drop down menus These are described in detail in the Menus section of this documentation The menus are displayed for all users except those logged in with only the Map role If you log in to an account with more than one type of access permission the right hand side of the menu bar lists the perspectives available to you If you have been assigned to all three of the UI perspectives then Observer Maintenance and Administrator will be listed in that order The active perspective is highlighted in orange Clicking on one of the other perspectives reloads the data area with the content association with that perspective The content of the data area is described in detail in the Observer Maintenance and Administrator sections of this manual The Observer and Maintenance perspective are further organized into tabs that run across the top of the data display The currently selected tab is highlighted in orange
27. rols for laying out the Observer screen views defining localized Alerts and grouping stations Like the Data Collection tab the Data Display tab is an accordion control and it has up to three panels depending on your configuration Alerts define localized alerts e Groups define and add stations to groups 5 8 Alerts Alerts are user defined conditions that are highlighted on the display Alerts are typically set to call attention to specific conditions such as high winds The INTERCEPT Alert feature provides compound alerts that are triggered when one or more criteria are met Alerts are named so that multiple alert conditions defined for the same data element can be easily distinguished Adding an Alert To add an alert perform the following steps 1 In the Maintenance perspective click on the Data Display tab 2 Click on the Alerts bar 3 Click the New Alert button beneath the Alert list box 4 In the Condition Editor select an Element The Element list contains all of the data elements that are retrieved from any of the connected stations 5 Next select an Operator There are three Operators available two for numeric data and one for text Use gt when creating an alert on numeric values that are greater than are greater than a specific value such as wind speed greater than 15 kts Use lt for numeric values that are less than a specific value such as temperature less than 34 6 Enter a Value
28. rs attached The INTERCEPT software performs the following functions e Gathers and displays the latest data from the configured data acquisition systems e Monitors the data quality e Checks the data for user configured alarm conditions and issues alarm messages accordingly e Archives data to disk e Provides data feed of real time data which can be collected for analysis on other systems e Allows multiple users to view the data on their own desktop via the web based user interface UI INTERCEPT can be installed on a PC or server running Windows XP Windows 2003 server VISTA or Windows 2008 Server 1 1 Document Conventions Alarm Used to refer to status information generated by a sensor WEATHERPAK or ZENO or the INTERCEPT application Alert An indication generated on the UI and within the XML feed when an alert condition is met An Alert condition is a set of criteria applied to one or more data elements as established by the user Algorithms Computations performed by the INTERCEPT application as opposed to averaging or other computations done within a sensor or by ZENO BIT Built In Test information is returned from the ZENO Some sensors also return bit encoded status information but that will be referred to as sensor status Log files Standard data files written by INTERCEPT There are log files for raw data as it comes in from the stations any algorithms that run in the application M
29. s 7 ADMINISTRATOR 7 1 User Administration An Administrator manages user accounts in INTERCEPT The Administrator perspective is used to create new accounts review or edit existing accounts and delete accounts The Administrator can also reset passwords for users who forget their password and can lock accounts To get to the User Administration screen select the Administrator perspective from the menu bar When opened the User Administration screen contains a list box showing all existing usernames To the right is the Create New User form Create a New User Account To create a new user account enter the account information in the Create New User form If the window is set to Edit mode click the Create New User button This will clear the form and reset it to Create New User mode 1 Enter a Username 2 Enter an Email Address 3 Enter a Password 4 Select one or more User Roles If none is selected the user will be set to the default role which is Observer 5 Optionally Enter a First Name and Last Name 6 Optionally set Console View 7 Click Save New User When a user has been added successfully the message New User Added will be shown in the ticker If a required field is empty or if one of the fields is not valid an error will be displayed in the ticker Editing a User Account To edit a user account click on the username The account settings will display in the Edit User Profile form The name username e
30. s a quick view of the wind data across all stations Like the Station Summary screen the Wind Dial tab shows all the stations not just those for the current group A wind dial is a graphical representation of wind data The dial represents the 360 degrees of wind direction with North at the top of the dial The usual configuration of the dial is to use the pointer to show the current wind direction the number in the center to show the wind speed and the wedge beneath the direction tick marks to show the wind direction variation 4 5 Status and Alerts The Status and Alerts window displays the most recent alarm and alert conditions The most recent is displayed on the top Alerts are displayed by date time station ID and the name given to the alert condition If a device has not passed its self test then a notification will be displayed with the date time device name and the status The Status and Alerts display can be closed using the X in the upper right hand corner 5 MAINTENANCE 5 1 Station Status The primary screen in the Maintenance perspective is the Station Status pane This pane allows the Maintenance Technician to see the status of all the connected stations at a glance At the top of the screen is an indicator for each station group The indicator has three color states Dark Gray all the stations in the group are disabled Green all the stations in the group are running without alarm conditions Red one or more sta
31. tion in the group has an alarm condition Each indicator has a button beneath labeled with the name of the group Clicking on one of these buttons displays the status for all of the stations in that group in the pane beneath the indicators The pane contains a text box for each station labeled with the station name and displaying The timestamp for the last message from the station The status of the station A button to disable the station A button to open a window with more Details about the station 5 2 Settings The Settings pane in the Maintenance perspective is for setting system properties The pane is divided into three sections e General Settings e Logging e Mail General Settings The following general settings can be modified Allow Sounds Checking this setting enables audio for Alert notifications Intercept Client Polling Interval seconds This value determines how frequently the client polls the server for data The default value is every 5 seconds However this can reasonably be set to the shortest sampling rate defined in the Sampling and Averaging section Max Time Between Polls Determines how many seconds can elapse between data samples before a timeout warning is set Logging The following logging settings can be modified Retain Data days Setting this property tells INTERCEPT how many days to retain logs Logs older than this value will be deleted Mail Mail Server Address Enter
32. views diagnostic information e Administrator a user who creates and edits user accounts assigning permissions to the available roles optional add on feature that provides a map view showing the locations of all stations connected to INTERCEPT with the data for the currently selected station on the right hand side A user can be assigned to more than one role At least one user must have Administrator permissions so that accounts can be managed The application ships with default user accounts created for each of the roles The account information for these accounts is included in the installation instructions 2 2 Overview The INTERCEPT application has two parts The INTERCEPT server installed on the computer that is connected to your stations collects data logs activity and responds to requests from the client The INTERCEPT client user interface UI is accessed through a browser The URL is http hostname intercept where hostname is the IP address or domain name of the server running your INTERCEPT software The UI requires the Adobe Flash player If you try to run the client without the correct version of the player a warning will be displayed along with a link to the download location on the Adobe site If your system cannot access the Adobe site the installer for the Adobe Flash player is included on the INTERCEPT installation CD The UI polls the INTERCEPT server for data at a regular i
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 - 三菱電機 Connex User Manual Rev 8_0311 UM-CONNEXSYS HDS Serie - Lowrance Model TB750G Right Angle Scattered Light Turbidimeter Metrologic MX001 Industrial Control Interface User Guide Esatto EMF87S User Manual User Manual - BDX3200KY Fieldvue DVC 6200 Instruction manual NHX2.5TC1A51の仕様図はこちら(PDF) Copyright © All rights reserved.
Failed to retrieve file