Home
Datasheet - Mouser Electronics
Contents
1. TP113 Universal K Type Air Probe Temp Range 40 F to 500 F 40 C to 250 C TP115 Universal Type General Purpose Probe Temp Range 40 F to 1562 F 40 C to 850 C SALES amp CONTACT WARRANTY Protek Test and Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 E Mail sales protektest com www protektest com Protek T amp M Limited Warranty Protek T amp M products are warranted against defects in workmanship and materials to the user for a period of 2 years from the date of purchase 90 days for models priced less than 75 00 All warranty claims must be sent in to an authorized repair depot transportation prepaid and must be accompanied by a copy of the sales invoice if a warranty Protek T amp M reserves the right to repair or replace all such defective products All repaired or replaced units will be returned transportation charges prepaid Products subjected to physical or electrical abuse or if used in an unprescribed manner are not covered by this warranty This limited warranty does not apply to batteries or fuses Copyright Protek Test amp Measurement Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery amp Lifecycle Information Protek TP111 TP115
2. Multimeter Selection Guide Function Generator Selection Guide Bench Type Hand Held Type Model B4100 B940 B845 6500 6800 Model B8011 B8400 B8110 B821 No counts 200 000 4 000 20 000 50 000 80 000 Freq Range 0 02Hz 2MHz 0 004Hz4MHz O 01Hz10MHz 0 2Hz 20MHz No Digits 51 2 3 3 4 4 1 2 4 4 5 4 7 8 Counter Yes Yes Dual Display 5 Sine Yes Yes Yes Yes Analog Bar graph Square Yes Yes Yes Yes Trend plot display x Triangle Ramp Yes Yes Yes Yes Back light r Pulse Yes DCV accuracy x 0 0576 x 0 376 x 0 0576 x 0 0376 x 0 0576 Burst Yes True RMS si ii Gate Trigger Yes Yes AC DC Meas id i Lin Sweep Yes Yes Yes Yes DB Log Sweep Yes Yes Capacitance i ii 5 TIL Out Yes Yes Yes Yes Frequency 5 b Ext Input Yes Yes Yes Pulse width Sweep Yes Yes Duty Cycle Start Stop Temperature 5 Sweep Out Yes Yes Continuity buzzer si 8 Diode Test Pulse Generator 5 Peak Hold L Compare go no go Min Max Avg i Relative mode Memory Sto RCL t GPIB interface Optional RS232 Interface si 2 x Comments Selectable count Delay hold Auto hold Resolution Approvals GE CAT Il CAT Ill CAT II 600V CE 1000V CE 1000V CE CAT III 600V CE Power Supply Selection Guide Triple Output Double Output Model 3033B 3040T 3030T 3030D 3032B 3015B Volts O to 30V 2 5V Fixe
3. Product Catalog Table of Contents Oscilloscopes Special Purpose Instruments Accessories Copyright Protek Test amp Measurement Analog Oscilloscopes 6020 6030C Hand Held DSOs 820 840 860 52401 52405 ti Single Output Analog Readout 303 310 Single Output Digital Readout 1805 3003B 3005B 3006B Dual Output Digital Readout 3015B 3032B Triple Output Digital Readout 3033B 3040T LCD Digital Displays 3030 3030D 3030T Programmables P6000 Electronic Load L300 n Loop Calibrator 30C Bench B940 B4100 B845 Hand Held 6800 6500 Clamp On 304 305 A480B Sweep Function B801 1 B8400 B8110 B1990 B821 Universal C3100 B3110 B8118 LCR Meter 29218 28200 Hand Held Capacitance Meter CM109 CM110 Hand Held LC Meter CL200 Signal Strength Analyzer 3201 3290 AM FM Signal Generator B1240 Audio Products SL100 B850 Insulation Tester DI2001 DI4000 Protek Test and Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com n 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35 36 37 38 39 40 41 42 43 44 Selection Guide
4. 3mV Line Regulation 0 02 3mV Ripple and Noise 0 5mV RMS Constant Current Mode Load Regulation 0 3 3mA Line Regulation 0 3 3mA Ripple and Noise 3mA RMS Digital Display Type 3 digit LCD Resolution Volts 100mV Resolution Amps 10mA Accuracy Volts 0 2 2d Accuracy Amps 1 3d General Specifications AC Input Volts 120 220V Power Consumption 305VA 50 60Hz Operating Temperature 0 to 35 C 32 to 95 F Size 7 5 H x 10 6 W x 13 0 D Weight 22 lbs Supplied Accessories Manual Line cord Test Leads 2 sets 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 eH wh pif 2028 08008 3030T SPECIFICATIONS 3030T Triple Output Outputs 1 and 2 Volts 0 to 30V DC Amps 0 to 3A Constant Voltage Mode Line and Load Regulation 0 02 3mV Ripple and noise 0 5mV RMS Constant Current Mode Load and Load Regulation 0 3 3mA Ripple and Noise 3mA RMS Digital Display Type 3 digit LCD Resolution Volts 100mV Resolution Amps 10mA Accuracy Volts 0 2 2d Accuracy Amps 1 3d Output 3 Volts Max 5V Current Max 3A Load and Line Regulation 0 02 3mV Ripple and Noise 0 5mV RMS General Specifications AC input Voltage 120 220V Power Consumption 310VA 50 60Hz Operating Temperature 0 to 35 C 32 to 95 F Size 7 5 H x 10 6 W x 13 0 D Weight 23 1 Ibs Supplied Accessories Manual
5. X10 Attenuator Extends input range Belt Clip Hands free transport LCD Display Bright easy to read 192 x 192 pixels up to 160 channels Function Keys Fast entry of preset or custom values and functions Numeric Input Keys or For entering 8 digit freq values On Off Power Auto power off saves batteries LCD Key Varies contrast for easy viewing Marker Frequency Ref Level Marker Level Center Frequency Span Frequency Step Frequency Menu for Funtion Keys CHANNEL EDIT MODE Up to 1600 channels may be stored in any order then scanned and identified by 9 digit freq and 5 letter title Useful for Cable TV Cellular phone and other field applications where repetitive measurements need to be made Antenna or Coax Input Protek Function Mode Scan Mode Volume Control Title Name SPECTRUM ANALYZER DISPLAY TWO CHANNEL DIFFERENCE MODE This Mode displays 2 carrier levels and their difference A key application verifies that a TV or Cable channel s video and audio carriers are within specifications BAR GRAPH DISPLAY This feature makes level readings easy and cleans up each frequency compared to a spectrum display Patterns may be readily seen for example this display of computer monitor radiation 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Hand Held 2 9GHz RF Signal Strength Analyzer
6. Measures frequency ms Pulse width and duty cycle AC and AC DC TRUE RMS measurements dBm measurement using 20 reference Impedances Peak hold and Relative mode CE and Category Il 1000V and Cat 1 600V safety standards 6800 AC True RMS Current Ranges 80mA 400mA 8A 10A Best Resolution 1 0u A Accuracy 0 5 10d 50Hz to 1KHz Accuracy AC DC Amps 1 0 10d 50Hz to 200Hz Overload Protection 800mA 250 fuse and 10A 250V fuse DBM Range 80dBm to 80dBm Best Resolution 0 01dBm Accuracy 1 0 or reading Default Ref impedance is 6009 Ref Impedances from to 12000 maybe selected Resistance Ranges 8000 8KQ 80K 5 800K o 8M 2 80M C2 Best Resolution 10 0mO Accuracy 0 3 10d Max Input Voltage 250V Diode and Continuity Test Range 8 00V Accuracy 3 104 The Buzzer sounds when the measured resistance is lt 50Q Frequency Ranges 1KHz 10KHz 100KHz 1000KHz 8MHz Best Resolution 0 01Hz Input sensitivity 0 7V AC rms Accuracy 0 05 5d Max Input Voltage 250V Frequencies to 1Ghz can be read with optional adapter Secondary display reads Duty cycle and mS pulse width RPM Range 0 to 99 999 Resolution 1R PM Accuracy 0 1 5d Note The RPM function is the secondary display of the frequency measurement and requires the RPM adapter T Sipe tip GREENER EBEN E WEE 5 Protek C Il 11 1000V CAT 111 600V 10A mA CO
7. Earphone J ack For noisy environment operations Input for Frequency Counter Built in 9MHz to 2900MHz Audio Speaker Dial Knob Fast one hand selection of menu items and freq marker DC Input J ack Accepts AC DC adaptor car adaptors and battery charger included Frequency keys Marker or Menu edit RS 232C Connector Printer or computer connection Software included DISPLAY Attenuantor Value Marker Sequency Level Sweep Mode Reception Mode SPECTRUM DISPLAY This Mode scans and displays 160 channels Squelch level may be set above or below carrier level in order to pause scan and detect the signal Detection modes are AM NFM WFM and SSB Protek Test amp Measurement Synthesized AM FM Signal Generator 10 KHz to 1040KHz frequency range AM PM and FM modulation 127dBm to 6dBm output level Self Test and Calibration capabilities 25W reverse power protection 100 location memory for storing Frequency modulation and output level data Optional GPIB interface SPECIFICATIONS Frequency Range 10KHz to 1040MHz Display Resolution 10Hz 10KHz to 520MHz 20Hz 520MHz to 1040MHz Accuracy 1 5 x 10 6 after 20 minutes of warm up Output Characteristics Output level Range 127dBm to 6dBm Display Resolution 0 1dB Accuracy 10 gt 10dBm 2dB 10dBm Amplitude Flatness lt 0 5dB 10KHz to 1040KHz 10dBm to 6dBm Output impedance 509 Amplitude Units dBm and dBu
8. Software key Her HOLD SAVE POWER AUTO SCOPE METER Measure Cursor Encoder S W for easy and Fast access MULTIMETER INPUT Volts Resistance Capacitance Diode Continuity Aux Temperature Currents Humidity Pressure Record Length A long record length and high speed sampling rates allows the user to capture and view a more detailed picture of a complex Waveform and it components Up to 125kB samples of waveform information may be captured and accurately displayed on the LCD screen as show in the illustration below 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Hand Held DSO DMM 820 840 860 Main Display waveforms and indicators Oscilloscope i 1 1 CH1 and CH2 waveforms along with the Dual channel Math waveform trigger levels horizontal positions offsets V div and Time division settings are displayed Meter m A457 mU Max 4500mU at 20 05 05 Min 4258mU at 20 12 18 Aug 443 2mU Analog Bargraph MIN MAX AVG VOLT DC etc Math Dual channel Math functions are available for adding and subtracting waveforms applied to the CHA and CHB inputs The FFT allows you to view a waveform spectrum using a Rectangular Hamming Hanning or Black Man Harris window Protek Test amp Measurement Website www protektest com Email sales protektest com 50MS s 1MHz Hand Held DSO DMM Dual Channel 50MS s sampling rate 5
9. 0 01Hz Accuracy 0 2 Rdg 2d Maximum Input 250V DC or AC RMS General Specifications Operating Temperature 0 to 40 C 32 to 104 F relative humidity 0 to 80 R dg Size 9 6 H x 3 4 W x 1 7 D J aw Size 2 25 Weight 15 oz Power 2 1 5V AAA batteries Accessories Manual Test leads Carrying case 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com AC DC Clamp On Meter Measures AC DC current to 1000A Meets IEC 1010 Category IIl 600V A480B 300 Amp Analog Clamp On Meter E Temperature measurement Meter Lock Switch freezes measured reading for closer examination at safe location E For use in plant maintenance HVAC electrical installation motor repair and similar applications A480B Volts DC Range 60V Sensitivity 8KQ V Accuracy 3 FS Volts AC Ranges 150V 300V and 750V Sensitivity 2KQ V Accuracy 3 FS AC Current Ranges 6A 60A 300A Accuracy 5 FS Temperature Ranges 20 to 150 C Accuracy 5 FS Resistance Ranges X1Q and X10Q Mid Scale 30Q and 300Q Accuracy 4 of FS General Specifications Size 9 0 H x 3 0 W x 1 5 D J aw Size 2 5 Weight 1 Ib Power 1 1 5 V AA battery Accessories Manual Test leads Carrying case 2 MHz Sweep Function Generator Sine Square Ramp and Pulse wave forms Built in 2MHz frequency counter 7 frequency ranges wi
10. 100mV Div into 50Q Display Modes CH1 CH2 ALT Chop ADD X Y Maximum Input Voltage 400V DC or AC peak Horizontal Sweep Sweep Times 100ns Div to 0 2s Div in 20 steps 1 2 5 seq 10ns Div to 20ms Div X10 Mag Mag X10 Accuracy 3 8 X10 Mag Sweep Modes TV Normal and Single Triggering Source CH 1 CH 2 ALT Line and EXT Slope Positive or Negative adjustable levels Coupling AC DC Normal TV Sensitivity Int DC to 20MHz 1 Div Ext 0 3V p p TV Int 2 Div Ext 0 3V p p Trigger Lock 50Hz to 10MHz 2 Div External Trigger Input Impedance 1 5 Maximum Input Voltage 400V DC or AC p p Z Axis Modulation Minimum Input Level TTL Maximum Input Voltage 50V or AC p p Polarity Intensity increases as the voltage decreases Input Resistance 10KQ Bandwidth 3dB DC to 5MHz X Y Mode Inputs X Axis CH1 Y Axis CH2 Sensitivity Same as CH1 Frequency Response 3dB DC 0Hz to 1MHz AC 10Hz to 1MHz Maximum Voltage Same as CH1 X Y Phase Difference 3 Calibrator Signal Waveform Square Wave Amplitude 0 5V 2 p p Frequency 1KHz 2 SPECIFICATIONS Component Test A 60Hz 9V RMS signal is applied to the CH1 and CH2 input when the AC DC GND is in the GND position and the component test button is pushed in General Specifications CRT 8cm x 10cm 3 15 x 3 94 Power Requirements AC Input Voltage 120V or 220V Frequency 50 60Hz Power Consumption 35W Operating Temper
11. 100uV Slow and Med 1mV Fast Accuracy 0 5 5d 45Hz to 450Hz Overload Protection 1000V Crest Factor 3 1 DC Current Ranges 200uUA 200mA 10A Best Resolutions 200uA 1nA Slow 10nA Med 100nA Fast 200mA 1 Slow 10u Med 100 Fast 10A 100 Slow 1mA Med 10mA Fast Accuracy 0 1 5d Max burden 200mV Overload Protection 0 5A 250V and 10 250V fuse B4100 AC Current Best Resolutions 2001 A 10nA Slow and Med 100nA Fast 200mA 1 Slow 10u A Med 100A Fast 10 100 Slow 1mA Med 10mA Fast Accuracy 0 5 50 Max burden 200mV Overload Protection 0 5A 250V and10A 250V fuse Resistance Ranges 2009 2KQ 200KQ 2MQ 10M Best Resolutions 1mQ Slow 10 Med 100mQ Fast Accuracy 0 05 5d Overload Protection 250V or AC RMS Frequency Ranges 200Hz 2KHz 20KHz 200KHz Best Resolutions 1mHz Slow 10mHz Med 100mHz Fast Accuracy 0 05 2d Overload Protection 250V DC or AC RMS Diode Range 2V Test Current Approximately 1 0mA Test Volts Approximately 3V Continuity Buzzer will sound at 100 2 or less Interface Type RS 232 Connector 9 Pin din Baud Rate 1200 2400 4800 or 9600 bps GPIB optional General Specifications Display 128 x 64 pixel super twist LCD Size 3 3 H x 9 5 W x 10 5 D Weight 3 2 lbs Operating Temperature 0 to 50 C 32 to 120 F Power 85V to 275V 10 Supplied Accessories Manu
12. 1V Accuracy 0 8 1d Maximum Input 500V DC or AC RMS Volts AC Ranges 500V Best Resolution 0 1V Accuracy 1 0 3d 40Hz to 400Hz Maximum Input 500V DC or AC RMS Resistance Ranges 2000 Best Resolution 0 10 Accuracy 1 2 4 5d Maximum Input 400V or AC RMS DC AC Current Ranges 200 and 1000A Best Resolution 0 1A Accuracy 1 2 5d Maximum Input 1200A DC or AC RMS General Specifications Power 9V battery Size 7 1 H x 1 9 W x 1 4 D Weight 20 oz Accessories Manual Test leads Carrying case Protek Test amp Measurement 305 3 3 4 Digit True RMS AC DC Clamp On Meter True RMS AC Measurements Auto Manual ranging Frequency counter 40 segment analog bar graph 2 1 4 Jaw opening Safety Standards 305 305 Volts DC Ranges 400mV 4V 40V 400V 600V Best Resolution 100u V Accuracy 0 5 Rgd 3d Maximum Input 1000V DC or 750V RMS Input Impedance 10MQ Volts AC Ranges 4V 40V 400V 600V Accuracy 0 5 Rdg 5d Maximum Input 750V RMS Input Impedance 10MQ Resistance Ranges 400Q 4KQ 40KQ 400KQ 4MQ 40MQ Best Resolution 0 10 Accuracy 1 5 5d Maximum Input 250V DC or AC RMS DC AC Current Ranges 400 and 1000A Best Resolution 0 1A Accuracy 2 0 Rdg 5d Maximum Input 1000A DC or AC RMS Continuity Buzzer Buzzer will sound lt 40Q resistance Frequency Ranges 100Hz 1KHz 10KHz 100KHz 1MHz Best Resolution
13. Counter Bandwidth 9MHz to 2900MHz Resolution 1KHz Accuracy 50 1 count Input Impedance 50Q Max Input Volts 5V RMS Response Time 0 512 sec 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Input Sensitivity 9MHz to 2060MHz 120mV 20MHz to 1500MHz 50mV 2MHz to 2800MHz 500mV 2800MHz to 2900MHz 750mV Data Memory Stores 10 Readings Miscellaneous LCD 192 x 192 Pixels Light green Back Light LED Back light will shut off 5 seconds after the last key depression Interfaces Std RS 232 interface with female 8 pin mini Din connector Baud Rates of 1200 2400 4800 or 9600 BPS are menu selected The software supplied is a Windows based program which runs under Windows 95 98 M E XP 2000 Auto Power Off 5 10 20 or 30 minutes after the last key depression user selected Audio Output 120mW into 8Q Speaker Power Requirements 6 AA NiCd or Alkaline Batteries 12 volt car adapter or 11V to 16V 500 mA Max AC to DC adapter General Specifications Operating Temperature 0 C to 40 C 32 to 104 F Relative Humidity 35 to 85 Storage Temperature 10 to 50 C 14 to 122 F Size 9 5 H x 4 0 W x 1 8 D Weight 1 4 105 Supplied Accessories Manual 6 1 5V AA NiCd Batteries Detachable 9 whip antenna RS 232 Cable and Software Carrying case Earphone Carrying strap Vehicle power adapter AC DC adapter Holster
14. Line cord Test Leads Protek Test amp Measurement Website www protektest com Email sales protektest com Programmable Power Supply All values may be entered from keyboard or rotary dial RS 232 485 interface with cable adapter and software CD Volts amps and power are displayed on a backlit LCD display 10 settings may be stored in memory Light weight and energy efficient Over voltage and current protection Outstanding in Production Test Applications P6000 SPECIFICATIONS Output Voltage Read Back Accuracy 25 C General Specifications Range 0 to 36V Voltage 0 to 19 999V 0 2 20mV AC Input Volts 110 220V 50 60Hz Voltage Resolution 20 to 36V 0 2 100mV Power Consumption 200VA 1mV 0 to 3 999V Current 0 2 20mA Operating Temp 0 to 50 C 32 to 120 F at relative humidity of 10mV 4 to 36V Program Resolution 0 to 80 Output Amps Voltage 0 to 3 999V 1mV 4 to 36V 10mV Size 3 5 H x 8 3 W x 9 8 D nas pss Manual Line cord Handels RS 232 Amps Resolution 1mA Read back Resolution uppiied Accessories Manual Line cord nandels RS adapter and cables Constant Voltage Mode Voltage 0 to 19 399V 10mV 20 to 36V 100mV Optional Accessories USB adapter and cables Load Regulation 0 02 10mV Current 1mA Line Regulation 0 to 3 999V 0 01 3mV Interface 4 to 36V 0 02 10mV RS 232 adapter and cables Ripple 1mV RMS Software Constant Current Power MS Power Management
15. Noise 1mV RMS Constant Current Mode Load Regulation 0 05 5mA Line Regulation 0 05 0 25mA Ripple and Noise 2mA RMS Digital Display Resolution Volts 100mV Current 10mA Accuracy 0 5 3d General Specifications AC Input Voltage 120 220V Power Consumption 300VA 50 60Hz Operating Temperature 0 to 35 C 32 to 95 F Size 6 3 H x 9 2 W x 12 8 D Weight 20 Ibs Supplied Accessories Manual Line cord Test Leads 2 sets Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com 3033B 3040T 3033B Triple Output Power Supply with Digital Displays Dual O to x30V with to 1 5 Amps Load current outputs and a fixed 5Volt at 5 Amp output Both Variable outputs have a Voltage and Current display Series output tracking Small case size Excellent Line Load and Ripple specifications Triple Output Power Supplies with Digital Displays 3040T Triple Output Power Supply with Series Parallel Tracking Outputs may be independent or connected in Series or Parallel and are selectable from the front panel Fixed supply may be switched between 3 3V and 5 0V Series or Parallel Master Slave tracking modes Energy saving design SPECIFICATIONS 3033B Outputs 1 and 2 Volts 0 to 30V DC Amps 0 to 1 5 Constant Voltage Mode Load and Load Regulation 0 02 2mV Ripple and N
16. Off Power Auto power off saves batteries LCD Key Varies contrast for easy viewing Marker Frequency Ref Level Marker Level Center Frequency Span Frequency Step Frequency Menu for Funtion Keys Protek RF FIELD STRENGTH ANALYZER Function Mode Scan Mode Volume Control Title Name SPECTRUM ANALYZER DISPLAY CHANNEL EDIT MODE Up to 1600 channels may be stored in any order then scanned and identified by 9 digit freq and 5 letter title Useful for Cable TV Cellular phone and other field applications where repetitive measurements need to be made TWO CHANNEL DIFFERENCE MODE This Mode displays 2 carrier levels and their difference A key application verifies that a TV or Cable channel s video and audio carriers are within specifications BAR GRAPH DISPLAY This feature makes level readings easy and cleans up each frequency compared to a spectrum display Patterns may be readily seen for example this display of computer monitor radiation Hand Held 2GHz RF Signal Strength Analyzer Earphone J ack For noisy environment operations Input for Frequency Counter Built in 9MHz to 2060MHz Audio Speaker Dial Knob Fastone hand selection of menu items and freq marker DC Input ack Accepts AC DC adaptor car adaptors and battery charger included Frequency keys Marker or Menu edit RS 232C Connector Printer or computer connection software included Attenuantor Value Ma
17. Output Power Supplies with Digital Displays 3015B 3032B 3015B Dual Output Power Supply to 30V with 1 5Amps load current Energy saver design allows cooler operation Excellent Load line and Ripples specs Front panel indicators for Constant Current and Constant Voltage operation Each output has two 3 digit LED displays for monitoring Voltage and current 3015B Outputs 1 and 2 Volts 0 to 30V DC Amps 0 to 1 5A Constant Voltage Mode Load Regulation 0 02 2mV Line Regulation 0 02 2mV Ripple and Noise 1mV RMS Constant Current Mode Load Regulation 0 05 5mA Line Regulation 0 05 0 25mA Ripple and Noise 2mA RMS Digital Display Resolution Volts 100mV Current 10mA Accuracy 0 5 3d General Specifications AC Input Voltage 120 220V Power Consumption 150VA 50 60Hz Operating Temperature 0 to 35 C 32 to 95 F Size 6 3 H x 9 2 W x 12 8 D Weight 16 5 lbs Supplied Accessories Manual Line cord Test Leads 2 sets 3032B Dual Output Power Supply to x30V with 3 0 Amps load current Low noise Linear supply for powering sensitive circuits Fully isolated outputs for connecting outputs in series Excellent Load line and Ripple specs Energy Saver design for cooler operation 3032B SPECIFICATIONS 3032B Outputs 1 and 2 Volts 0 to 30V DC Amps 0 to 3A Constant Voltage Mode Load Regulation 0 02 2mV Line Regulation 0 02 2mV Ripple and
18. Output Protection 25W of reverse power Spectral Purity Spurious Better than 35dB at carrier frequency lt 62 5MHz and 0dBm Better than 25dB at carrier frequency gt 62 5MHz and 0dBm Residual Modulation FM 7Hz AM 0 0596 Modulation FM Deviation 0 to 100KHz 1Mz to 1040MHz Carrier Freq x 1096 below 1MHz Resolution 10Hz 0 to 10KHz deviation 100Hz 10KHz to 100KHz deviation Protek Test amp Measurement B1240 Accuracy 5 for 1KHz or 400Hz modulation Frequency Response 0 5dB 50Hz to 50KHz Distortion lt 2 THD 1KHz Mod Max deviation and Carrier Freq gt 250KHz PM Range 0 to 10 Radians Resolution 0 01 Radians Frequency Response 1dB 10KHz to 10KHz Deviation Accuracy 5 at 1KHz Modulation AM Range 0 to 99 Resolution 0 5 Accuracy better than 4 of depth setting 1 at 1KHz Frequency Response 0 5 50Hz to 50KHz Envelope Distortion 3 THD at 70 mod and 1KHz Modulation Oscillator Frequency 1KHz and 400Hz External modulation Input Range 10Hz to 50KHz Input Level 0 9V to 1 1V RMS With Modulation ALC Input Impedance 100K 2 Approx Memory Locations 0 to 19 store Frequency Modulation and Output level data Locations 20 to 99 store Frequency data only 3 independent memories for storing output level data 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Display Ca
19. Test leads SPECIFICATIONS 3003B Output Volts 0 to 30 V DC Output Amps 0 to 3 Amps Constant Voltage Mode Load and Line Regulation 0 02 2mV Ripple and Noise 1mV RMS Constant Current Mode Load Regulation 0 0596 5 Line Regulation 0 0596 0 25mA Ripple and Noise 2mA RMS Digital Display Resolution Volts 100mV Amps 10mA Accuracy 0 596 3d General Specifications AC Input Voltage 120 220V selectable Power Consumption 190VA Operating Temperature 0 to 32 C 32 to 90 F Size 6 3 H x 5 0 W x 13 0 D Weight 15 Ibs Supplied Accessories Manual Line cord Test leads Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Single Output Power Supplies 3005B 3006 with Digital Displays 3005B Single Output Power Supply O to x30V with to 5 Amps Load current Internal fan for cooler operation Excellent Line Load and Ripple specifications Small case size Designed with energy saving circuitry Fully isolated output terminals for series operation Short circuit and Reverse Voltage protected SPECIFICATIONS 3005B Output Volts 0 to 30V DC Output Amps 0 to 5Amps Constant Voltage Mode Load and Line Regulation 0 02 2mV Ripple and Noise 1mV RMS Constant Current Mode Load Regulation 0 05 5mA Line Regulation 0 05 0 25mA Ripple and N
20. amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 15 Website www protektest com Email sales protektest com 300W Maximum Power Programmable 300W Electronic Load Operates in Constant current Constant resistance or Constant power modes mA current setting resolution Voltage Current and Power are displayed on the back lit display Back light LCD Values may be enter from key board of rotary dial RS232 interface and control software Small size and light weight SPECIFICATIONS Inputs 1 Input Volts 0 to 360V Input Current 0 to 30A Input Power 0 to 300W Operating Modes Constant current Constant Resistance or Constant power Voltage Resolutions 0 000V to 3 999V 0 2 3 4 00V to 35 999V 0 2 30mV 36 0V to 360 0V 0 2 30 Current Resolutions 0 000A to 2 999A 0 2 3mA 3 00A to 35 999 A 0 2 3mA Current Setting Resolution 1mA 0 to 2 999A 10mA 3 00A to 30A Power Setting Resolution 0 1W 0 to 300W Resistance Setting Resolution 0 010 0 to 99 990 0 10 100 to 5009 Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Minimum Resistance 0 08 Ripple 10mV Protection Over Voltage Over Current Over power Over Heating and Reverse polarity Power 120 220V 50 60Hz Communication
21. leads Single Output Power Supplies with Digital Displays 1805 3003B 1805 Single Output Power Supply O to 18 Volts with O to 5Amps load current Excellent Load Line and Ripple specs Fully Isolated outputs terminals 3 digit Led displays for both current and Voltage Small case size Front panel Indicators for constant current and constant voltage operation Short circuit and Reverse Voltage protected 3003B Single Output Power Supply to x30V with O to 3 Amps Load current Constant Voltage and Constant current operation Units can be connected together in series for Higher output voltage Course and Fine controls for accurate Voltage settings Low noise and Linear supply for powering sensitive circuits Front panel push button switch disconnects power supply from Load 1805 Output Volts 0 to 18V DC Output Amps 0 to 5A Constant Voltage Mode Load Regulation 0 05 5 6mV Line Regulation 0 05 5 6mV Ripple and Noise 0 5mV RMS Constant Current Mode Load Regulation 0 05 20mA Line Regulation 0 05 8mA Ripple and Noise 5mA RMS Digital Display Type 3 digit red LED Resolution Volts 100mV Amps 10mA Accuracy Volts 0 2 2d Current 1 3d General Specifications AC Input Voltage 120 220V selectable Power Consumption 170VA Operating Temperature 0 to 32 C 32 to 90 F Size 6 3 H x 5 0 W x 13 0 D Weight 15 Ibs Supplied Accessories Manual Line cord
22. protektest com Email sales protektest com Loop Calibrator 24 volt internal loop supply Auto Step and Auto ramp modes no need for external mA meter Simultaneous mA and read out fo quick easy interpretation of reading resolution for mA source simulate and measure 25 step button for quick linearity tests Large 4 2 digit 20 000 count LCD display Encoder dial for easy one handed operation mA Source Display POWER Loop Power Display Voltage Source Display Loop Calibrator Protek 30c 30C Voltage Measure Display Simulator Display SPECIFICATIONS Measurements General Specifications Voltage Operating Temperature 10 to 55 C 14 to 1319F Ranges 2 20 50Volts iio 1 9V battery Best Resolution 100u V Size 2 H x 3 5 W x 1 5 D Accuracy 0 05 5d Weight Overload Protection 100VDC or AC peak Accessories Test Leads Instruction manual carrying case and 9 Volt battery Current Ranges 2mA and 20mA Accuracy 0 05 5d Best Resolution 0 10 A Sourcing Current Range 4 to 20mA Values from 0 to 24mA maybe obtained through overlapping Accuracy 0 025 50 Loop power 24V Voltage Range 2V and 20V Accuracy 0 05 50 TX simulator Type 2 wire transmitter simulation External Excitation Voltage 3V min to 50V max Simulation current 4 to 20mA Values from 0 to 24mA maybe obtained through overlapping Output current Ramp Range 4mA to 20
23. software Load Regulation 0 02 10mV ActiveX and DLL Support tools for VC VB Delphi LabView Line Regulation 0 02 10mV upon request Ripple and noise 4mV Rms Memory Program Accuracy 25 C 10 Locations EEPROM for saving power settings Voltage 0 1 20mV Current 0 1 20mA Protection Over voltage over current and power Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Please Input Config Params ID Power Name Power Address a Current Up A Programmable Power Supply Configuration screen Program up to 16 model P6000 Power Supplies from this screen Power Manage System Params Setting COM Baud 19200 E Default Power 0 Communication Setting Used to configure communication related settings ox Control e bon Power State e Vol Run Chart 10 20 30 40 50 60 70 80 90 10 Cur Run Chart 10 20 30 40 50 60 70 80 90 100 Power 1 Addo 365 30 108 0 Power System V2 0 2004 10 12 Tuesday 02 03 00 PM Main screen Displays feedback from the hardware and allows the user to control various parameters directly from the computer software Protek Test
24. www protektest com Email sales protektest com High Accuracy Wide Range LCR Meter with LCD Readout 0 02 Basic accuracy Wide measurement Ranges for Capacitors Resistors and Inductors Menus and parameters are displayed on an easy to read 320x 240 Graphics LCD with backlight Measurement Rates to 12 times per second 500 Test Frequencies from 12Hz to 100KHz Open and short circuit compensation for accurate zeroing Binning and Pass Fail operation Measurement averaging from 1 to 255 Optional GPIB and handler interface LCD displays measured values Q D Absolute A and A SPECIFICATIONS Measured Components L Inductance C Capacitance R Resistance Measurement Circuit configurations Series and Parallel Measurements Resistance Measured Parameter R Q Measurement Ranges R 10uQ to 100M 2 Q 0 0001 to 9 999 Inductance Measured Parameter L Q Measurement Range L 0 011 H to 99 999 H Q 0 0001 to 9 999 Capacitance Measured Parameters C D and C4 Measurement Range C 0 00001pF to 99 999uF D 0 0001 to 9 999 R 0 00010 to 9 999K Display Display Type 320x 240 Graphics LCD W Backlight Display value 5 digit LCR and a 4 digit Q D measurement Parameters Displayed Measured values absolute A and 96A Test Environment Test Frequencies 500 test frequencies from 12Hz to 100KHz Test Voltage 5mV to 1 275V in 5mV increments Test Voltage Accuracy 5 5mvV 1 001 x F2 Measurement rates Slow 1 M
25. 00mV Div Vertical sensitivity 2401 SPECIFICATIONS Vertical Oscilloscope Bandwidth 1MHz Resolution 8 bits Number of Channels 2 Coupling AC and DC Input Impedance 1M Accuracy 3 Max Input Volts 600V DC or AC RMS Vertical Sensitivity 500mV Div to 500V Div in a 1 2 5 sequences Horizontal Oscilloscope Sample Rate 50MS s single channel 25MS s dual channel Record Length 512 bytes single shot and Glitch capture 256 bytes all other modes Samples Div 25 samples Update Rate Real time Modes Single shot roll mode normal Accuracy 0 01 Sweep Rate 1us Div to 5s Div in a 1 2 5 sequences Memory 16 waveforms and setups may be saved in memory Triggering Oscilloscope Trigger source CH A CH B External Coupling AC DC Trigger sensitivity 2 20 Division Trigger Modes Auto and Normal Slope Positive and Negative Protek Test amp Measurement DC Volts Digital Multimeter Ranges 5V 50V 500V 1000V Best Resolution 1mV Accuracy 0 3 3d Input Impedance IMQ AC Volts Ranges 3V 30V 300V 750V Best Resolution 1mV Accuracy 0 7596 54 40Hz to 450Hz 2 50 450Hz to 5KHz 2 596 54 5KHz to 20KHz Input Impedance IMQ Max Input Volts 600V DC or AC RMS Ohms Ranges 5KQ 50KQ 500KQ 5MQ Best Resolution 1 Accuracy 0 5 50 Overload Voltage 600V DC or AC peak Continuity Test Voltage 1 7V Threshold 100 digits Overload Voltage 600V DC
26. 0V Frequency 50 60Hz Power Consumption 10W Max Operating Temperature 0 to 40 C 32 to 104 F at 85 Relative Humidity Size 4 3 H x 10 6 W x 10 2 D Weight 5 5 Ibs Accessories Manual Line cord Test leads with Kelvin clips CM109 3 1 2 Digit LCD Capacitance Meter Measures capacitance to 20mF m Zero adjust m Fused input m Large LCD display m Rugged case design Inputs for clip leads and lead Insertion CM109 CM109 Capacitance Range 200pF 2nF 20nF 200nF 2uF 20uF 200uF 2000u F 20mF Best Resolution 0 1pF Accuracy 0 5 Rdg 1d 200pF to 200u F Ranges 1 Rdg 1d 2000UF Range 2 Rdg 1d 20mF Range Test Frequencies 200pF to 2uF Ranges 200Hz 20u F Range 80Hz 200uF to 20mF Ranges 8Hz Zero Adjustment Range 20pF Overload Protection 0 25A 250V fuse General Specifications Power 9V battery Operating Temperature 0 to 40 C 32 to 104 F with a relative humidity of less than 70 Size 5 3 H x 2 8 W x 1 3 D Weight 7 5 oz Supplied Accessories Manual Test leads Battery Capacitance Inductance Meter CM110 3 1 2 Digit 2000 Count Capacitance Meter Zero adjust for compensating stray capacitance E Large easy to read 3 1 2 digits 2000 count LCD 0 5 measurement accuracy Fused input 9 measurement ranges Three measurement frequencies Includes holster CM110 CM110 Measurement Condition Specifications are measured within a te
27. 120 F Dimensions 4 3 H x 12 5 W x 14 D Weight 15 Ibs AC line Voltage 120 220V 50 60Hz Accessories Manual line cord BNC cable B8110 B1990 SPECIFICATIONS B1990 Frequency Characteristics Frequency Range Internal 1Hz to 10M Hz 100ns to 1s in 7 ranges Xtal 10Hz to 10MHz Output Characteristics Amplitude 0 5 to 5V p p into 50 2 Impedance 50Q Input Impedance 2KQ Rise Time 10ns into 50 2 Output Polarity Positive or Negative Pulse Width Range 50ns to 5ms in 5 ranges Pulse Delay Range 0 to 2us in Trigger Trigger modes Internal Ext or edge triggered Xtal and Manual Trigger out Width 20ns Amplitude 5V Impedance 50 External Trigger in Input V range 1 0V to 1 0V P P sine or square wave Repetition Rates 10Hz to 10M Hz Impedance 2KQ General Specifications Operating Temperature 0 to 40 C 32 to 104 F atless than 85 humidty Stability 0 196 per hour after warm up Dimensions 4 3 H x 11 4 W x 10 2 D Weight 6 4 Ibs AC line Voltage 120 220V 50 60Hz Accessories Manual line cord BNC cable Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 27 Website www protektest com Email sales protektest com 20 MHz Sweep Function Generator Sweep Function Generator and Frequency Counter Internal and External linear Sweep control Variable Output level control and 20 dB attenuator B821 Swe
28. 50s Div 860 5ns Div to 50s Div Time base Accuracy 0 01 Acquisition system Acquisition Modes Sample Peak detect Envelope Average Sampling Real Time and Equivalent 840 860 Sample Rates 820 100MS s 840 860 200MS s single channel and 100MS s per channel Dual channel Equivalent Sampling 840 2 56 5 5 860 565 5 Sample Rate Accuracy 100ppm Record Length 125KB Channel Waveform Interpolation Dot Linear Sine and Pulse Peak Detect 10ns minimum Averages 2 to 256 Trigger Sensitivity 0 5 Div DC to 5MHz Trigger Types Edge Pulse width Video Coupling AC DC HF Reject LF Reject Noise Reject Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Modes Normal Single Roll Auto Trigger Level Range 20 Div from the center of the screen Trigger Level accuracy 0 4 Div Trigger sources CHA and CHB Video Trigger Video Trigger sensitivity 0 7 Div Video Type NTSC PAL Secam Measurements Types P P Max Amplitude Top Base Pos Neg over shoot Pre shoot RMS Mean One cycle mean Freq Period Width Duty cycle Rise Fall time Delay and Phase shift Math Operations CHA4CHB CHA CHB CHB CHA FFT 840 860 Cursors AV AT FFT 840 860 Weighting Rectangular Hamming Hanning and Blackman Harris Amplitude display 1 2 5 10dB Div Maximum Frequency 1 25GHz Memory 10 w
29. 5232 or RS485 Memory 10 setups may be stored and recalled Software Monitor software CD ActiveX modules for VC 4 Visual basic Delphi and LabView upon request General Specifications Size 3 5 H x 8 3 W x 9 8 D Weight 11 lbs Supplied Accessories Manual Line cord Handles RS 232 adapter and Cables Optional Accessories USB adapter and Cable Program Setting StepttData Step1 Time 5 0 00 00 __ ini x 0 00 00 0 00 Step1 O T inne 00 0 00 FeadParam Step Read Param State ElectronicLoad Setting r 2 E ir 2 af ee Current Setting 47 E E Power Setting Enter B C E B C Resistor Setting Configuration screen Allows the user to set various parameters for the program Flectronic Load Programmable 300W Electronic Load ioixi COM Setting Address COM Setting 0m BaudRate 5600 Communication Setting Used to configure communication related settings Power State READ j Input Low e SET Over Voltage e Over Power e Main screen Displays feedback from the hardware and allows the user to control various parameters directly from the computer software Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www
30. 5MS s dual channel Record Length 512 bytes single shot and Glitch capture 256 bytes all other modes Samples Div 25 samples Update Rate Real time Modes Single shot roll mode normal Accuracy 0 01 Sweep Rate 1us Div to 5s Div in a 1 2 5 sequences Memory 16 waveforms and setups may be saved in memory Triggering Oscilloscope Trigger source CH A CH B External Coupling AC DC Trigger sensitivity 2 20 Division Trigger Modes Auto and Normal Slope Positive and Negative 50MS s Dual Channel 5MHz Hand Held DSO DMM 50MS s sampling rate 50mV Div Vertical sensitivity Auto ranging Vertical and Horizontal scales Built in auto manual ranging True RMS 4000 count DMM DC to 5MHz bandwidths Hand held and battery operated Designed to UL3111 CSA C22 2 No 1010 standards RS 232 Port and supplied software User friendly front panel x Hat gt as Wi i is 2 mE 10 LN ui 13 ws 15 16 11 18 19 j ET Hd DC Volts Digital Multimeter Ranges 5V 50V 500V 1000V Best Resolution 1mV Accuracy 0 3 3d Input Impedance IMQ AC Volts Ranges 3V 30V 300V 750V Best Resolution 1mV Accuracy 0 7596 54 40Hz to 450Hz 2 50 450Hz to 5KHz 2 596 54 5KHz to 20KHz Input Impedance IMQ Max Input Volts 600V DC or AC RMS Ohms Ranges 5 50KQ 500KQ 5MQ Best Res
31. Data Memory Stores 10 Readings 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Miscellaneous LCD 192 x 192 Pixels Light green Back Light LED Back light will shut off 5 seconds after the last key depression Interfaces Std RS 232 interface with female 8 pin mini Din connector Baud Rates of 1200 2400 4800 or 9600 BPS are menu selected The software supplied is a Windows based program which runs under Windows 95 98 ME XP 2000 Auto Power Off 5 10 20 or 30 minutes after the last key depression user selected Audio Output 120mW into 8Q Speaker Power Requirements 6 AA NiCd or Alkaline Batteries 12 volt car adapter or 11V to 16V 500 mA Max AC to DC adapter General Specifications Operating Temperature 0 C to 40 C 32 to 104 F Relative Humidity 35 to 85 Storage Temperature 10 to 50 C 14 to 122 F Size 9 5 H x 4 0 W x 1 8 D Weight 1 4 105 Supplied Accessories Manual 6 1 5V AA NiCd Batteries Detachable 9 whip antenna RS 232 Cable and Software Carrying case Earphone Carrying strap Vehicle power adapter AC DC adapter X10 Attenuator Extends input range Belt Clip Hands free transport LCD Display Bright easy to read 192 x 192 pixels up to 160 channels Function Keys Fast entry of preset or custom values and functions Numeric Input Keys 4 or For entering 0 digit freq values On
32. F output levels in memory and recall them when needed 14 When pressed an External Reference frequency will be used 15 Modulation On or Off key 16 The Input connector for the external modulation signal when External Modulation is selected The Modulation output signal is present at this connector when internal modulation is selected 17 When this key is press the input modulating signal is kept at a constant level 0 9V to 1 1V 18 2nd Function Key Some keys on the front are dual function pressing this key enables the second function 11 12 13 23 24 19 Selects if data is being stored in or recalled from the displayed memory 20 Keypad Enter values for the RF Frequency output level Modulation or memory display when selected 21 Rotary knob Used also for entering Frequency output level Modulation or memory values in the selected display 22 Frequency step keys Increases or decreases the frequency by a Preset value 23 These keys increase 4 or decrease the output level by a Preset value 24 N type RF 50Q output connector PANELS STD FREQ INPUT REMOCON DC 5V STD FREQ Fuse ADJ 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Power Cable Connector Line Selector Protek Test amp Measurement 51100 B850 SL100 Sound Level Meter m ANSI amp IEC 651 T
33. H x 9 0 W x 13 0 D Weight 16 5 Ibs Supplied Accessories Manual Line cord Test Leads 3 sets Power Supplies with LCD Digital Displays 3030 3030D 3030T Large LCD display with back light for displaying Voltage and Current settings Outputs may be connected in series or parallel 3030D and 30307 Constant voltage and current selection switch Incremental switch for setting Max current value Excellent line and load regulation characteristics Fully isolated outputs for series or parallel operation Automatic cooling fan operation 10 turn voltage control for precise voltage settings Extended Barrier strip output connection 3030 Single Output Output Volts 0 to 30V DC Output Amps 0 to 3A Constant Voltage Mode Load Regulation 0 2 3mV Line Regulation 0 2 3mV Ripple and Noise 0 5mV RMS Constant Current Mode Load Regulation 0 3 3mA Line Regulation 0 3 3mA Ripple and Noise 3mA RMS Digital Display Type 3 digit LCD Resolution Volts 100mV Resolution Amps 10mA Accuracy Volts 0 2 2d Accuracy Amps 1 3d General Specifications AC Input Voltage 120V only Power Consumption 160VA Operating Temperature 0 to 32 C 32 to 90 F Size 7 5 H x 5 1 W x 11 0 D Weight 11 lbs Supplied Accessories Manual Line cord Test leads 3030D 3030D Dual Output Outputs 1 and 2 Volts 0 to 30V DC Amps 0 to 3A Constant Voltage Mode Load Regulation 0 02
34. M VQHz Capacitance Ranges 1nF 10nF 100nF 1uF 10uF 100uF Best Resolution 1pF Accuracy 2 5 10d 5 10d 1nF range Maximum Input Volts 250V Temperature Ranges 50 to 1372 C 58 to 2502 F Thermocouple K type Display C primary display F secondary display Resolution 0 1 Accuracy 2 5 8d Square wave Generator Amplitude Approx 3V Frequencies from 0 500Hz to 5 000KHz may be selected in 15 Steps Duty Cycle Variable from 1 to 99 General Specifications Operating Temperature 0 to 502C 32 to 1229F Power 9Volt battery 36 Hours of operation Size 7 5 H x 3 54 W x 1 45 D Weight 1 43 lbs Auto Power Off 30 minutes or the timer value Accessories Instruction manual Test leads Holster Temperature probe 9V battery RS 232 software and cable DC mV Ranges 50mV 500mV Best Resolution 14V Accuracy 0 03 6d Input Impedance 1GQ DC Volts Ranges 5V 50V 500V 1000V Best Resolution 1004 V Accuracy 0 03 6d Max Input Voltage 1000V DC Input Impedance 10M AC mV Ranges 50mV 500mV Best Resolution 14V AC mV Accuracy 40Hz to 1Khz 0 5 40d 1KHz to 10KHz 1 0 404 10KHz to 20KHz 2 5 404 Input Impedance 160 AC Volts Ranges 5V 50V 500V 1000V Best Resolution 1004 V AC Volts Accuracy 5V to 500V ranges 40Hz to 1KHz 0 5 40d 1KHz to 10KHz 1 0 40d 10KHz to 20KHz 2 5 404 Max Input Vol
35. MHz Resolutions 0 1Hz Gate Times 0 01s to 10s in 4 decades Accuracy Time base error 1 count Input B Range 100MHz to 1 3GHz Best Resolution 10Hz Gate Times 0 01s to 10s in 4 decades Accuracy Time base error 1 count Totalize Input A Frequency range DC to 10MHz Count Capacity 0 to 99 999 999 counts Resolution 1 count Minimum Pulse width 250ns Accuracy 1 count Period Input A Range 1 0 us to 100ms 10Hz to 1MHz Minimum pulse width 250 5 Resolutions 100ps 1ns 10ns 100ns Accuracy Time base error 1 count Trigger error GATE TIME PERI MULT FREQ MHz 015 ts 11 xw 8 am ON sort d SPECIFICATIONS Input Characteristics Input A Sensitivity 50 mV 10Hz to 100Hz 20mV 100Hz to 100MHz Input Impedance 1MQ 30pF capacitance Attenuator x1 x10 Coupling AC Maximum input volts 30V rms Input B Sensitivity 15mV 100MHz to 1000MHz 40mV 1000MHz to 1300MHz Input Impedance 500 Coupling AC Max input Volts 7V Time Base Frequency 10 00000M Hz Stability 3 PPM per week General Specifications AC input Volts 120V or 220V Line Frequency 50 60Hz Operating temperature 0 to 40 C 32 to 104 F Size 4 0 H x 10 0 W x 11 0 D Weight 3 75 Ibs Accessories Line cord Manual BNC cable Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website
36. Manual Test Probe Lead with Case 6 AA Batteries Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Accessories PPSO DC to 60 MHz X1 X10 Probes Max Input 600V P P PROBES amp Etc Test TL1O1 Leads TL102 TL206 TL250 TL501 TL505 TL102 TL206 CASES amp HOLSTERS Meter CB25A Carrying CB35D Cases CB50A CB50D CB506 CB77D DC to 100MHz X10 Probes Input Impedance TP25 TP 25 Temp probe for model A480B 9MQ resistance and 14pF Capacitance Max Input 600V P P A413 A410B A800 A801 D901 A403 305 307 A480B D640AB D1200D BT407 B845 D910F D980 D981 B4000 B4100 S2401 2405 TM1300K 304 505 506 A802 608 610 A421 A450 TL250 TL101 TL501 TL505 DI4000 A421 D910F D981 D980 A802 CM110 CL200 2700 A450 A803 FC250 505 506 608 610 CM109 D930A TM1300K Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com TP35 K type temp probe for models TM1300K D910F D981 A421 506 608 610 B4000 Susy TP111 Universal Type Immersion Probe Temp Range 40 F to 1562 F 40 C to 850 C TP112 Universal Type Surface Probe Temp Range 40 F to 950 F 40 C to 510 C AE
37. al Line cord Software disk RS 232 cable Test Leads Optional Acessories GPIB interface Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Bench Top Digital Multimeter 0 05 DC voltage accuracy 10pV AC amp DC voltage resolution 10nA current resolution 10mQ Resistance resolution Data hold switch Measures current to 10 Amps 200pA AC DC Current Range Protek DIGITAL MULTIMETER Se DC Voltage Range 200mV 2V 20V 200V 1000V Best Resolution 10u V Accuracy 0 05 Rdg 20 AC Voltage Range 200mV 2V 20V 200V 1000V Best Resolution 10u V Accuracy 0 5 Rdg 10d DC Current Range 200 2mA 20mA 200mA 10A Best Resolution 10nA Accuracy 0 3 Rdg 3d AC Current Range 200uA 2mA 20mA 200mA 10 Best Resolution 10nA Accuracy 0 75 Rdg 10d Resistance Range 2000 2KQ 20KQ 200KQ 2MQ 20MQ Best Resolution 10mQ Accuracy 0 2 Rdg 5d 4 1 2 Digit DMM 4 1 2 digit LCD display with polarity indicator L B845 SPECIFICATIONS Continuity Buzzer Will sound at lt 2000 Resistance Diode test Test Volt 2 8V Test Current 3mA General Specifications Operating Temperature 0 to 40 C 32 to 104 F ata relative humidity of 0 to 80 Power 115 230V 50 60Hz Size 3 0 H x 8 0 W x 10 5 D Weight 5 Ibs Supplied Accessories Manu
38. al Line cord Test leads Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Hi and Lo limit testing Min Max AVG 5232 port Built in 10 hour timer SPECIFICATIONS mV DC Ranges 80 mV 800 mV Best Resolution 1y V Accuracy 0 05 10d Input Impedance 16 DC Volts Ranges 8V 80 V 800V 1000V Best Resolution 100u V Accuracy 0 05 10d Max Input Voltage 1000V DC Input Impedance 10M AC mV Volts TRUE RMS Ranges 80mV 800mV 8V 80V 750V Best Resolution 1u V AC Volts Accuracy 80mV 800mV 8V ranges 50 60Hz 0 5 100 50Hz 1KHz 1 0 100 1KHz 10KHz 3 0 10d 10KHz 20KHz 5 0 104 AC Volts Accuracy 80V and 750V Range 1 from 50Hz to 400Hz AC 4 DC V Accuracy 1 0 10d 50Hz to 200Hz Max Input Voltage 1000 V DC or AC peak Input Impedance 10 1G 80mV and 800mV DC Current Ranges 80mA 800 8A 10A Best Resolution 1 0 A Accuracy 0 5 100 Overload Protection 0 8A 250V fuse and 10A 250V fuse Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com 80 000 Count Digital Multimeter 80 000 count Dual Display Basic DC accuracy is 0 05 Pulse output with frequency selection from 0 5Hz to 5KHz with duty cycles from 1 to 99
39. ature 0 to 40 C 32 to 104 F Size 5 1 H x 12 2 W x 16 45 D Weight 14 3 lbs Accessories Manual Line cord X1 X10 Probes 2 Test Leads Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com 820 840 860 20Mhz 820 40MHz 840 60MHz 860 bandwidths Built in High accuracy 6000 count True RMS DMM 200MS s sampling rate single channel and 100MS per channel in dual channel 840 860 100MS s 820 2 5GHz Equivalent sampling 840 and 5GHz Equivalent Hand Held DSO DMM Models 840 and 860 include FFT 125KB record length for each channel 10 waveforms and setups may be stored and recalled USB interface and optional flash memory port 840 860 High Resolution 320x 240 pixel Monochrome LCD sampling 860 Edge Pulse width TV Pattern and Delay trigger modes 20 automatic waveform Measurements Self test and Self calibration Help menu SPECIFICATIONS Vertical No inputs 2 Analog bandwidth 820 20M Hz 840 40M Hz 860 60M Hz Rise Time 820 17 5ns 840 8 75ns 860 5 83ns Sensitivity 5mV to100V div in a 1 2 5 sequence Resolution 8 bit Offset 5 div from the center Vertical Accuracy 3 Input Impedance 1MQ 1 and 20pF 1 3pF Max input V 300V DC or AC peak Probe Attenuation x1 and x10 Horizontal Sweep rates 820 50ns Div to 50s Div 840 10ns Div to
40. aveforms and settings saved and recalled DMM DC Volts Range 600mV to 1000V Accuracy 0 3 100 Best Resolution 1001 V Impedance 10MQ Overload protection 1000VDC or AC peak 820 840 860 AC Volts Range 6V to 600V Accuracy 0 75 10d 50Hz to 1KHz 2 0 104 1KHz to 30KHz Best Resolution 1mV Impedance 10M Overload protection 1000VDC or AC peak Resistance Range 600Q to 60M Accuracy 0 5 104 Best Resolution 100mQ Overload Protection 250V DC or AC peak Capacitance Range 60nF to 300g F Accuracy 2 0 10d Other measurements Diode test accuracy 2 Continuity Buzzer will sound lt 60Q dBm with reference impedances of 2 4 8 16 50 75 93 110 125 135 150 300 600 900 1K or 1 2KQ High current to 600A with external current Clamp Temperature with Probe to 6002C 1112 F General Specifications Size 8 3 H x 4 2 W x 2 2 D Weight 2 6 105 Power 9VDC 1A AC DC adapter 7 2V NIMH rechargeable battery pack Standard accessories AC DC adapter User s manual Scope probe 2 Holster Test Leads USB cable and software Optional accessories Battery pack Temperature adapter Clamp on current probe Carrying Bag and USB flash memory OSCILLOSCOPE INPUT amp Internal charger 320 x 240 pixel USB mini PC LCD Display Communication with Backlight Contrast USB Adjustment Flash memory Host i
41. ay SPECIFICATIONS General Specifications Size 3 3 H x 9 0 W x 9 4 D Weight 3 3 Ibs Power 9V NEDA battery not supplied or 90 to 132VAC 198 to 264VAC 9 50 60Hz Adapter Supplied Accessories Manual Test leads Carrying strap Line cord RS 232 cable Software CD Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Bench Top Digital Multimeter 5 1 2 Digit Programmable 5 1 2 Digit multimeter with selectable count resolutions up to 200 000 True RMS and measures frequency Selectable Count Resolutions 2K 20K 200K Auto ranging Trend plot display RS 232 interface standard and optional GPIB interface Min Max Avg Relative error and comparison functions May be used on line voltages from 85V to 250V without any internal changes Software included Seven setups may be stored and recalled in memory Protek 24100 Programmatic Muttimetor e 9e gt o _ SPECIFICATIONS B4100 Display Slow Counts 200 000 Digits 5 Medium Counts 20 000 Digits 4 Fast Counts 2 000 Digits 3 Specifications at 25 C 5 C 77 F 9 F DC Voltage Ranges 2V 20V 200V 1000V Best Resolutions 10uV Slow 100u V Med 1mV Fast Accuracy 0 05 3d Input Impedance 10MQ Overload Protection 1000V AC Volts Ranges 2V 20V 200V 1000V Best Resolutions
42. cteristics Waveforms Sine Square Pulse Triangle and ramp Impedance 50Q Attenuator 20dB 40 dB 60dB and 20 dB variable Amplitude 0 to 10 Volts in to an open circuit DC Offset 0 to 10 V in to an open circuit 0 to 5 into 50 2 Sine Wave Frequency Range 0 01Hz to 10MHz Flatness 3 5 from 0 01Hz to 100KHz 10 100KHz to 10MHz Harmonic Distortion lt 0 5 from 10 Hz to 40KHz Symmetry 20 80 to 80 20 Square Wave Frequency Range 0 01Hz to 10MHz Rise Fall Time lt 25ns into 50Q Pulse Frequency Range 0 01Hz to 10MHz Rise Time 10ns Duty Cycle adjustable symmetry control from 20 80 to 80 20 Ramp and Triangle Linearity gt 99 Operating Modes CW Triggered Gated Burst Sweep Trigger Gate input level TTL Trigger Gate Frequency Range DC to 100KHz Burst time 1ms to 10s Sweep Type Linear and Log Sweep Time 1ms to 2s in 2 ranges continuously variable Sweep width 1 100 continuously variable Sweep start frequency may be set with the SET MOD control Modulation Type AM Input External Through the MOD input connector Frequency DC to 1MHz Modulation Range 0 to 100 Modulation Voltage 0 to 5V P P Type FM Input External through the VCG input Tuning Range 1000 1 with an input of 0 to 5V Outputs Sync TTL level GCV output proportional to the selected frequency 0 to 5V Sweep 0 to 5V Sweep Burst Gate TTL level General Specifications Operating Temperature 0 to 50 C 32 to
43. d FM Wide Band FM AM and Single side band Input Input Impedance 50Q Maximum Input Volts 5V RMS 27dBm Measurement Units dBmV dBuV dBm Attenuation 0dB or 10dB internal OdB to 60dB with external Attenuator Narrow Band FM Level Measurement Range 117dBm to 67dBm 300MHz to 1800MHz 107dBm to 67dBm 1MHz to 300MHz and 1800MHz to 2900MHz Resolution 0 5dB Accuracy 30 Bandwidth 12 5KHz Wide Band FM AM amp SSB Level Measurement Range 107dBm to 57dBm 300MHz to 1800MHz 97dBm to 57dBm 10MHz to 300MHz and 1800MHz to 2900MHz Resolution 0 5dB Accuracy 30 Protek Test amp Measurement Bandwidth Wide band FM Approx 180KHz AM and SSB Approx 2 4KHz BFO Frequency Range 1 5KHz Reception Sensitivity 0 to 6dBuV EMF with supplied antenna Antenna Reception S N Ratio N FM 10 dB W FM 12 dB Display Display Modes Spectrum Bar graph Frequency counter Spectrum Display Displays 160 channels Bar Graph Displays Multi channel 2 5 10 20 40 80 160 bar graphs per display Single Channel and 2 Channel difference Sweep Modes Single Normal Free run Spurious Signals internally generated 35dBc for W FM 45dBc for N FM typical below full scale signal level Scan Mode Mode Manual Channel memory scan and Search scan Scan Rate 125 Ch sec Memory Data Memory Stores 10 displays of up to 160 CH per display Setup Memory Stores 10 setups for each scan mode Frequency
44. d O to 36V 2 3 3 5 0V Fixed O to 30V 2 5V Fixed O to 30V 2 O to 30V 2 O to 30V 2 Amps Oro ISAF 5A Fixed O to 2 5A 0 to 5 0A Fixed O to 3 0A O to 3 0A Fixed O to 3 0A O to 3 0A Ow 154A Display ZED ZED 2 2 LCD ZAED 2 LED Series Parallel Series Both Both Both N A N A AC Input Volts 120V 220V 120V 220V 120V 220V 120V 220V 120V 220V 120V 220V Power Consumption 192VA 455VA 310VA 305VA 300VA 150VA Size H x W x D in 5 x 11x 1S 65095013 Ores Weight Ibs 20 17 23 22 20 17 Single Output Programmable Model 3005B 3003B 3006B 1805 3030 310 303 P6000 Volts O to 30V O to 30V O to 60V O to 18V O to 30V O to x30V O to x30V O to x36V Amps O to 5 0A O to 3 0A Oto 1 5A O to 5 0A O to 3 0A O to 10A O to 3 0A O to 3 0A Display 2 LED 2 LED 2 ED 21ED 1 LCD Analog Analog 1 ICD AC Input Volts 120V 7 220V 120V 7 220V 120V 7 220V 120V7 220 120V 120V 220V 120V 220V 0702201 Power Consumption 133VA 190VA 190VA 170VA 160VA 520VA 190VA 200VA Size H x W x D in 5 9 x 13 Coco cs 50113 1 5906 x 13 A910 Weight Ibs 15 15 15 15 11 26 14 13 Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com 20MHz Dual Trace Oscilloscope with Alt Mag 20MHz Bandwidth Alt Mag sweep for simultaneous display of main and X10 magnifi
45. d Q D Auto ranging or Range hold Built in comparator with 4 bin sorting function Open and short circuit calibration for accurate zeroing Series and parallel equivalent circuit modes Three test frequencies Warning alarm for pass or fail binning Easy to use n ge SPECIFICATIONS Measurements Components L Inductance C Capacitance R Resistance Z Impedance Circuit Configuration Series and Parallel Parameters Displayed Measured values absolute Delta and Delta Resistance Impedance Measured Parameter R Q and Measurement Range R IMQ to 999 99MQ Q 0 0001 to 99999 Inductance Measured Parameter L Q Measurement Range L 14H to 999 99H 100Hz amp 120Hz L 0 1uH to 999 99 1KHz Q 0 0001 to 99999 28200 Capacitance Measured Parameter C D Measurement Range C 1pF to 999 99uF D 0 0001 to 99999 Test Environment Test Frequency 100Hz 120Hz 1KHz Test Voltage 0 3V RMS Drive Voltage Accuracy 10 Measurement Rate 2 Measurements S ec Ranging Auto or Hold Measurement Accuracy Basic Accuracy 0 3 23 C 5 C 73 F 9 F See user manual for detailed accuracy conditions Zero Input Correction Open and short circuit Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com General Specifications Power Requirement AC Voltage Input 120 22
46. ear sweep and 10 000 1 frequency log sweep widths Settable Sweep Start and Stop Frequencies Low Distortion sinewave CONT STOP ni LTIPLIER Hz wr TL 50n Pp pem MULTI P o 10 100 1K 10K 100K 1M 1 10 T SPECIFICATIONS Frequency Characteristics Frequency Range 0 004Hz to 4MHz in 7 ranges Ranges x1 x10x x100 x1K x10k x100k x1M Dial Accuracy 5 of full scale Output Characteristics Waveforms Sine Square Triangle TTL Pulse High output Amplitude 15mV to 10V into 50 2 DC Offset 0 to 5 into 50Q Impedance 50Q Attenuator 30dB variable Low Output Amplitude 0 to 1V into 500 DC Offset 0 to 0 5 into 50 2 Impedance 50Q Attenuator 30dB variable Sine Wave Frequency Range 0 004Hz to 4MHz Flatness 2 0 0 004Hz to 400KHz 10 400KHz to 4MHz Harmonic Distortion lt 0 5 on the 1K and 10K range 1 on the x1 x10 x 100 and x100K ranges 25dBc on the x1M range Square Wave Frequency Range 0 004Hz to 4MHz Rise Fall Time 50ns into 50Q High output terminals Symmetry 1 to 100KHz 5 to 4MHz Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com TRIG IN B8400 Triangle Linearity gt 99 to 200KHz Operating modes CW Triggered Gated Sweep Manually Triggered Trigger Gate input level TTL Trigger Gate Frequency Range to 4MHz Ma
47. eas sec Medium 5 Meas sec Fast 12 Meas sec Measurement Delay from 1ms to 99 999ms Ranging Auto or Manual DC Bias Internal 2V External 0 to 60V Triggering Continuous or Triggered Zeroing correction Open and short circuit Averaging 1 to 255 Avgs Measurement Accuracy Basic accuracy 20 0296 at 23 C 5 C 73 F 9 F See user manual for all accuracy conditions Remote Operation GPIB and Handler Optional General Specifications AC Voltage input 120 or 220 Volts Frequency 50 60 Hz Power Consumption 20Watts Max Operating Temperature 0 to 50 C 32 to 122 F at 8596 Relative Humidity Size 5 5 H x 15 W x 18 D Weight 17 6 lbs Accessories Manual Line Cord Kelvin leads with bag GPIB Handler Optional Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com High Accuracy Wide Range LCR Meter 320 x 240 pixel LCD for displaying the The function Keys selectthe component value along with its Q or D operating parameters displayed on EXT Bias key when in the C D or C R value in a absolute A or A display the LCD Trigger mode mode allows an external bias voltage Test Frequency Test voltage Measurement rate Component up to 60V to be applied to the Selects the type of component and Circuit mode Number of averages Binning value in absolute A or A are capacitor under test This is
48. ed trace Alternate trigger for a stable display of unrelated signals X10 Horizontal Magnification P P auto trigger High brightness CRT with internal graticule Z axis modulation Light weight with low power consumption SPECIFICATIONS Vertical Amplifier CH 1 and CH 2 Sensitivity 5mV Div to 5V Div in 10 steps 1 2 5 seq Accuracy 3 Bandwidth 3dB DC 0Hz to 20MHz AC 10Hz to 20MHz Rise Time 17 5ns Input Impedance Res 1 5 Cap 25pF 5pF Input Coupling AC DC GND Invert Channel CH2 Display Modes CH1 CH2 ALT Chop ADD X Y Maximum Input Voltage 400V DC or AC p p Horizontal Sweep Sweep Times 200ns Div to 0 5s Div in 20 steps 1 2 5 seq X10 Mag 20ns Div to 50ms Div Mag X10 Accuracy 3 8 X10 Mag Sweep Modes TV Normal Auto and p p Auto Triggering Source CH 1 CH 2 ALT Line and EXT Slope Positive or Negative adjustable levels Coupling AC Sensitivity Int DC to 10MHz 1 Div DC to 20MHz 1 5 Div Ext DC to 10MHz 0 3 p p DC to 20MHz 0 5 p p TV Synch Int 2 Div Ext 0 5V p p Auto Triggering gt 20Hz External Trigger Input Impedance IMQ 5 20pF Capacitance Maximum Input Voltage 160V DC or AC peak Z Axis Modulation Sensitivity 5V p p Maximum Input Voltage 50V or AC p p Polarity Intensity increases as the voltage increases Input Resistance 10KQ Bandwidth 3dB DC to 1MHz X Y Mode Inputs X Axis CH1 Y Axis CH2 S
49. ensitivity Same as CH1 Accuracy 5 Frequency Response 3dB DC 0Hz to 1MHz AC 10Hz to 1MHz Maximum Voltage Same as CH1 X Y Phase Difference 3 from DC to 50KHz Calibrator Signal Waveform Square Wave Amplitude 0 5V 3 p p Frequency 1KHz 2 CRT Size 8cm x 10cm 3 15 x 3 94 Acceleration Voltage 2KV General Specifications Power Requirements AC Input Voltage 120V or 220V Frequency 50 60Hz Power Consumption 40W Operating Temperature 0 to 40 C 32 to 104 F Size 5 1 H x 12 5 W x 15 75 D Weight 16 Ibs Accessories Manual Line cord X1 X10 Probes 2 Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com 30 MHz Dual Trace Oscilloscope with Component Tester 30 MHz Vertical Bandwidth 3dB LCR Component Tester Alternate Trigger for a stable display of unrelated signals X5 Mag for Vertical Input and X10 for Horizontal TV Synch Filter Trigger Signal Output High Brightness CRT with Internal Graticule Vertical Amplifier CH 1 and CH 2 Sensitivity 5mV Div to 20V Div in 12 steps 1 2 5 seq 1mV Div to 4V Div X5 Mag Mag X5 Accuracy 3 5 in X5 Mag Bandwidth 3dB DC 0Hz to 30MHz AC 10Hz to 30MHz Rise Time 18ns 70ns in X5 Mag Input Impedance Res 1 5 Cap 30pF Input Coupling AC DC GND Invert Channel CH2 CH1 CH2 Trigger Output
50. ep Function Characteristics Mode Linear E a a E m E m Variable DC Offset control iB SPECIFICATIONS B821 Output Characteristics Frequency Range Sine wave 0 2Hz to 20MHz Square amp Triangle wave 0 2Hz to 10MHz Range selection in 8 ranges 1 10 100 1K 10K 100K 1M 10M Output Level 20 1 Vp p in open circuit 10 0 5 Vp p into 50 Load Waveforms Sine Square Triangle Ramp Pulse Sawtooth TTL Leveled Square Attenuator 20dB fixed and continuously variable 20dB Impedance 500 0 5 Frequency Accuracy 5 of full scale Waveform Characteristics Sine Wave Flatness 3dB to 20MHz Distortion Less than 1 5 96 at 0 2Hz to 100KHz Duty error Less than 10 in 50 50 Square Wave Rise and Fall Time 25ns at 10MHz Triangle Wave Linearity More than 99 at 0 2Hz to 100KHz TTL Output Rise and Fall Time 25ns at 10MHz TTL Level H gt 24V L 0 4V Symmetry Variation Sine amp Square 80 20 to 20 80 at 0 2Hz to 2MHz Triangle 80 20 to 20 80 at 0 2Hz to 1MHz Width Variable from 1 1 to 10 1 Rate 0 5Hz to 50Hz 20ms to 25 External VCF Input Input Voltage 0 to 10V Input Impedance Approx 10KQ Frequency Counter Characteristics Display 8 digits Green LED Overflow Gate time MHz KHz Hz Frequency Range Input A 0 1Hz to 100MHz Input C 80MHz to 3 0GHz Accuracy Timebase Error 1 count Low pass Filter 3 dB 100KHz Timebase 10MHz TCO 1 ppm Input Sensitivity I
51. eriod Time Interval Ratio and Totalize High Stability TXCO Variable Trigger level on Inputs A and B Large Bright 8 digit LED display With gate time and function indicators Low Pass filter and X10 attenuator SPECIFICATIONS Frequency Measurement Input A Ranges Low Range DC coupled 0 1Hz to 10MHz AC coupled 10Hz to 100MHz High Range 10MHz to 100MHz Best Resolution Low Range 0 1Hz High Range 1Hz Gate Times 0 01s to 10s in 4 decades Accuracy Time base error 1 count Input B Used only for Ratio A B and Time interval Range DC coupled 0 1 to 10MHz AC coupled 10Hz to 100MHz Freq Range 100MHz to 3 0GHz Best Resolution 10Hz Gate Times 0 01285 0 1285 1 285 and 12 85 Accuracy Time base error 1 count Totalize Input A Frequency range DC to 10MHz Count Capacity 0 to 99 999 999 counts Resolution 1 count Minimum Pulse width 250ns Accuracy 1 count Time Interval A gt B Inputs A and B Protek Test amp Measurement Range 0 5us to 200ms 5Hz to 2MHz Minimum Pulse Width 250ns Best Resolution 100ns Multipliers x1 x10 100 1000 Accuracy Time base error 1 count XInput A Trigger error Multiplier Ratio Inputs A and B Range CHA 10MHz to 100MHz CHB 0 1Hz to 10MHz Resolution Input B input A x multiplier Accuracy xInput B trigger error Input B x Gate time 1 count Period Input A Range 0 55 to 200ms 5Hz to 2MHz Minimum pulse widt
52. h 250ns Best Resolution 100ps Accuracy Time base error 1 count xInputA Trigger error Input Characteristics Inputs A amp B Sensitivity 25mV Input Impedance 1MQ 40pF capacitance Attenuator x1 x10 Coupling AC and DC Low pass filter To approx 100KHz Slope Plus or Minus Trigger level 350mV variable and OV fixed Maximum input volts 250V DC or AC peak 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Input C Frequency Range 100MHz to 3 0GHz Sensitivity 15 100MHz to 800MHz 60mV 800MHz to 3 0 GHz Maximum input voltage 3V rms Attenuator None Input Impedance 500 Coupling AC Time Base Type TXCO Frequency 10 00000M Hz Stability 3 0 PPM per week Time base output 500mV p p into 50Q General Specifications AC input Volts 100V 120V 220V 240V Line Frequency 50 60Hz Power consumption 20VA Operating temperature 0 to 40 C 32 to 104 Size 4 0 H x 10 0 W x 11 0 D Weight 5 25 lbs Accessories Manual Line cord BNC cable High accuracy frequency measurements to 1 3 GHz Frequency Resolution to 0 1Hz High input sensitivity Large Bright 8 digit LED display With gate time and function indicators X10 attenuator Measures Frequency Period and Totalise 1 3GHz Multi Function Counter DISPLAY HOLD RESET Frequency Measurement Input A Range 10 Hz to 100
53. mA Ramp Times 5s 20s 50s Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com DC Voltage True RMS AC volts and amps measurements Capacitance and Frequency measurements Back lit display and Auto Manual ranging MIN MAX and Relative mode Delay hold mode AC Line or Battery Operated RS 232 Interface with software Portable or Bench with Pop up Stand Storage Compartment B940 Range 400mV 4V 40V 400V and 1000V Best Resolution 0 1mV Accuracy 0 3 2d AC Voltage Range 4V 40V 400V and 750V Best Resolution 1 0mV Accuracy 0 8 5d DC Current Range 4mA 40mA 400mA and 10A Best Resolution 14A Accuracy 0 8 5d AC Current Range 4mA 40mA 400mA and 10A Best Resolution 14A Accuracy 1 5 50 Resistance Range 4000 4K Q 40KQ 400KQ 4M 40M Best Resolution 0 10 Accuracy 0 5 5d Frequency Range 100Hz 1KHz 10KHz and 600KHz Best Resolution 0 01Hz Accuracy 0 1 2d Capacitance Range 4nF 40nF 400nF 4uF 40uF Best Resolution 0 1pF Accuracy 2 4d Diode test Test Volt 3 V Test Current 0 6mA Continuity Buzzer will sound at lt 40Q Resistance Bench Top Digital Multimeter 3 3 4 Digit DMM with RS 232 V m mn PE BE EREERRERERERRERER UE Software Displ
54. mH to 200mH range 5 1d 2H range Test Frequency 900Hz General Specifications Power 9V NEDA Battery Calibration Interval 1 year Operating Temperature 0 to 40 C 32 to 104 F with a relative humidity of less than 70 Size 7 4 H x 3 7 W x 1 3 D Weight 7 5 oz Supplied Accessories Manual Test leads Holster Protek Test amp Measurement Website www protektest com Email sales protektest com Hand Held 2GHz RF Signal Strength Analyzer Hand Held and battery operated 100KHz to 2060MHz measurement range 12 5 Ch sec scan rate Built in 2GHz frequency counter High sensitivity 117 dBm max Detects Wide band and Narrow band FM AM and Single Sideband Signals Phase lock loop for precise frequency tuning RS 232 interface includes software and cable Up to 160 channels may be scanned and displayed Audio output with built in speaker Detachable antenna included Back lit display All functions are menu selected Instrument setups amp display data may be stored in memory Hard copy printer output of spectrum and bar graph displays SPECIFICATIONS Frequency Frequency Range 100KHz to 2060MHz Frequency Step 5KHz to 9995KHz in multiples of 5KHz or 6 25KHz Ref Oscillator Accuracy 3 PPM Frequency Marker Accuracy 25 PPM Frequency Measurements Narrow Band FM Wide Band FM AM and Single side band Input Input Impedance 50Q Maximum Input Volts 5V RMS 27dBm Measurement U
55. mperature range of 18 C to 28 C 64 F to 82 F Capacitance Ranges 200pF 2nF 20nF 200nF 2uF 20uF 200p F 2000 F 20000uF Best Resolution 0 1pF Accuracy 0 5 14 200pF to 200u ranges 1 1d 2000F range 2 1d 20mF range Test Frequencies 200pF to 2uF ranges 800Hz 20u F range 80Hz 200uF to 20 000UF ranges 8Hz Zero Adjustment Range 20pF Overload Protection 0 25A 250V fuse General Specifications Power 9V Battery Calibration Interval 1 year Operating Temperature 0 to 40 C 32 to 104 F with a relative humidity of less than 7096 Size 7 4 H x 3 7 W x 1 3 D Weight 7 5 oz Supplied Accessories Manual Test leads Holster 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 CM109 CMI TIO CL200 CL200 3 1 2 Digit 2000 Count L C Meter Six capacitance ranges and four inductance ranges High accuracy measurement Automatic zeroing Low battery indicator Fuse protected input Includes holster CL200 SPECIFICATIONS CL200 Measurement Condition Specifications are measured within a temperature Range of 18 to 28 C 64 to 82 F Capacitance Ranges 2nF 20nF 200nF 2uF 20g F 200p F Best Resolution 1pF Accuracy 1 14 2nF to 200nF ranges 2 1d 2u to 200UF ranges Test Frequencies 2nF to 2uF ranges 900Hz 20 uF and 200uF ranges 80Hz Inductance Ranges 2mH 20mH 200mH 2H Best Resolution 1u H Accuracy 2 1d 2
56. nits dBmV dBuV dBm Attenuation 0dB or 10dB internal OdB to 60dB with external Attenuator Narrow Band FM Level Measurement Range 117dBm to 67dBm 1MHz to 2060MHz Resolution 0 5dB Accuracy 30 Bandwidth 12 5KHz Wide Band FM AM amp SSB Level Measurement Range 108dBm to 58dBm 10MHz to 2060MHz Resolution 0 5dB Accuracy 30 Bandwidth Wide band Approx 180KHz AM and SSB Approx 2 4KHz BFO Frequency Range 1 5KHz Reception Sensitivity 0 to 6dBuV EMF with supplied antenna Antenna Reception S N Ratio N FM 10 dB W FM 12 dB Protek Test amp Measurement Display Display Modes Spectrum Bar graph Frequency counter Spectrum Display Displays 160 channels Bar Graph Displays Multi channel 2 5 10 20 40 80 160 bar graphs per display Single Channel and 2 Channel difference Sweep Modes Single Normal Free run Spurious Signals internally generated 35dBc for W FM 45dBc for N FM typical below full scale signal level Scan Mode Mode Manual Channel memory scan and Search scan Scan Rate 12 5 Ch sec Memory Data Memory Stores 10 displays of up to 160 CH per display Setup Memory Stores 10 setups for each scan mode Frequency Counter Bandwidth 9MHz to 2060MHz Resolution 1KHz Accuracy 50 1 count Input Impedance 50Q Max Input Volts 5V RMS Response Time 0 512 sec Input Sensitivity 9MHz to 2060MHz 120mV 20MHz to 1500MHz 50mV 2MHz to 2060MHz 500mV
57. normally parameter to be measured and the Soft Keys for selecting these some of the functions that may be used to stabilize a High value R amp Q 160 C amp D C amp R or Auto parameters are also displayed selected Electrolytic for an accurate reading may be selected Sa Mita e e p rI Q c c een Protek X pwiuTAL L c R METER MODEL 29218 RAFS DOOQOU D Va Bias off 3236 1 0 4380 Serial Numeric keyboard for entering Test Frequency Voltage values Number of averages Cal Data Measurement delay and Nominal values Four wire input 2 inputs supply the drive signal and 2 inputs are for input sensing thereby removing errors caused by lead length These two keys are used to adjust the contrast of the LCD display Cs 5 7066nF L Q MEASUREMENT SCREEN Rato Slow Circuit 7 8 9 10 a LZ ud 4 5 6 wa ES LJ 1 2 3 20 10 EX EXT BIAS d um u The start key initiates a measurement in the triggered mode SCREENS Modi Iriqget Hit START key SHORT CIRCUIT CALIBRATION SCREEN Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com LCR Meter Measures L C R Z Q and D Displays component value Q or D Delta or Delta 5 digit display for component value an
58. nput A 30mVrms 0 1Hz to 80MHz Input A 70mVrms 80MHz to 100MHz Input C 20mV rms 80MHz to 2 0GHz Input C 70mVrms 2 0GHz to 3 0GHz with RG58 cable Input C 40mV rms 2 0GHz to 3 0GHz with RG400 cable Max Input Voltage Input A 35Vp p Input C 3Vrms Sine Square Triangle Ramp Pulse Skewed Sine and TTL Square Waveforms 0 2Hz to 20MHz Frequency Output Sine wave Built in 8 digit 3 0GHz Frequency Counter Variable Symmetry for generating Sawtooth Ramp Skewed Sine and Pulse Waveforms General Specifications Power Requirements 115 230VAC 10 48 to 66Hz Operating Temperature 0 to 40 C Accuracy specified at 23 C 5 C 32 to 104 F Accuracy specified at 73 F 9 F Size 3 5 H x 9 5 W x 11 0 D Weight 6 6 lbs Supplied Accessories Manual Line cord BNC cable Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Programmable 2 4GHz Universal Counter Accurate frequency measurements to 2 4GHz Measures Frequency Period Duty Cycle RPM Frequency ratio Difference frequency Time interval and Totalize Nine measurement functions Plots trend graph on LCD display Compare Relative Error and Min Max functions Standard RS 232 with optional GPIB interface Eight setup screens may be saved and retrieved from memory Software for controlling displaying data and data l
59. ogging Operates on all line voltages from 85V to 270V without any changes Frequency Measurement Freq A Ranges DC coupled 0 to 120MHz AC coupled 10Hz to 120MHz Resolution 0 00001Hz 200Hz Gate Times 50ms to 10s 20 settings Accuracy 2PPM Coupling AC or DC Trigger Level 1 8V in a scale from 99 to 99 Freq B Ranges DC coupled 0 to 120MHz Protek C3100 Programma Universal Counter 9523338 C3100 Time Interval AB Input CH A and CH B Range 0 5us to 200 000u s Minimum Pulse Width 250ns Resolution 115 Accuracy 1 count timebase accuracy Ratio A B Inputs CH A and CH B Range CH A 10MHz to 150MHz CH B 0 1MHz to 10MHz SPECIFICATIONS Channel C Frequency Range 100MHz to 2 4GHz usable to 2 7GHz Sensitivity 25mV RMS 100MHz to 2 4GHz Maximum Input voltage 5V DC or AC peak Attenuator None Input Impedance 50Q Reference Timebase Oscillator Standard Frequency 10MHz 4 194304MHz Frequency Stability 5 0 PPM Max Aging Rate 1 0 PPM Max Yr 5 MUS Resolution 0 000001 Temperature 30 to 60 C 22 to 140 F i M zQ 5 Storage Temperature Range 40 to 85 40 to 185 Gate Times 50ms to 10s 20 settings Duty Cycle Accuracy 2PP M Coupling AC or DC Input CH A Software Trigger Level 1 8V in a scale from 99 to 99 Freq C Ranges 100MHz to 2 4GHz Resolution 100Hz 500MHz Gate Times 50ms to 10s 20 settings Accuracy 2 1 coun
60. oise 1mV RMS Constant Current Mode Load Regulation 0 0596 5 Line Regulation 0 05 0 25mA Ripple and Noise 2mA RMS Digital Display Outputs 1 amp 2 Resolution Volts 100mV Current 10mA Accuracy 0 5 3d Tracking Error 0 5 10mV Output 3 Volts Max 5V 0 2 5 Amps Max 5A 2 5 Load Regulation 0 2 2mV Line Regulation 0 2 2mV General Specifications AC input Voltage 120 220V 50 60Hz Power Consumption 192VA Operating Temperature 0 to 35 32 to 95 F Size 6 3 H x 9 0 W x 13 0 D Weight 20 lbs Supplied Accessories Manual Line cord Test Leads 3 sets Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com 3040T Outputs 1 and 2 Volts 0 to 36V DC Amps 0 to 2 5A Constant Voltage Mode Line and Load Regulation 0 02 2mV Ripple and noise 0 2mV RMS 4mV P P Constant Current Mode Load Regulation 0 0596 5 Line Regulation 0 05 0 25mA Ripple and Noise 2mA RMS 10mA P P Digital Display Outputs 1 and 2 Resolution Volts 100mV Current 10mA Accuracy 0 596 14 Output 3 Volts Max 3 3V 5V 2 5 selectable Current Max 5A 2 5 Load and Line Regulation 0 1 5mV Ripple 2mV RMS General Specifications AC input Voltage 120 220V 50 60Hz Power Consumption 455VA Operating Temperature 0 to 35 C 32 to 95 F Size 6 3
61. oise 2mA RMS Digital Display Resolution Volts 100mV Amps 10mA Accuracy 0 5 3d General Specifications AC Input Voltage 120 220V selectable Power Consumption 133VA Operating Temperature 0 to 32 C 32 to 90 F Size 6 3 H x 5 0 W x 13 0 D Weight 15 Ibs Supplied Accessories Manual Line cord Test leads 3006B Single Output Power Supply O to 60V with O to 1 5 Amps Load current Excellent Line Load and Ripple specifications Short Circuit and Reverse Voltage protected Constant Voltage and Constant Current operation 3 digit Led displays for both current and Voltage Front panel Indicators for Constant Voltage and constant current operation 3006B Output Volts 0 to 60V DC Output Amps 0 to 1 5A Constant Voltage Mode Load and Line Regulation 0 02 2mV Ripple and Noise 1mV RMS Constant Current Mode Load Regulation 0 05 5mA Line Regulation 0 05 0 25mA Ripple and Noise 2mA RMS Digital Display Resolution Volts 100mV Amps 10mA Accuracy 0 596 3d General Specifications AC Input Voltage 120 220V selectable Power Consumption 190VA Operating Temperature 0 to 32 C 32 to 90 F Size 6 3 H x 5 0 W x 13 0 D Weight 15 Ibs Supplied Accessories Manual Line cord Test leads Protek Test amp Measurement 10 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Dual
62. oltage Ranges 0 to 750V Resolution 1V Accuracy 0 8 Rdg 4d Mega Ohms Ranges 0 to 250MQ 250V 0 to 250MO 500V 0 to 2000M 1000V Resolution 0 1M 250MQ Range 1 0MQ 2000M Range Accuracy 3 5d Display 2000 Count 3 1 2 Digit General Specifications Power 8 1 5V AA Batteries Operating Temperature 0 to 40 C 32 to 104 F at a relative humidity of lt 8096 Size 6 3 H x 3 8 W x 2 0 D Weight 17 02 Supplied Accessories Manual Test probe Leads Batteries DI4000 SPECIFICATIONS DI4000 AC Voltage Ranges 0 to 600V Resolution 1V Accuracy 2 5 Rdg Input Impedance 20MQ Max Input 600V Insulation Measurement Effective Measuring Resistance 20 9 125V 50M 250V 2000MQ 1000V Rated Measurement Current Approx 1mA 20 0 Short Circuit Current 2mA Minimum Measurable Resistance 20M Range 0 125MQ 50MQ Range 0 250M 1000MQ Range 1 0 MQ Accuracy 125V 0 020 to 10M lt 5 500V 0 1M to 50M Q lt 5 1000V 2M Q2 to 100000 lt 5 125V 0 1MQ to 0 03MQ and 10M to 100M 2 lt 10 500V 0 05MQ to 0 1M 2 and 50MQ to 100MQ lt 10 1000V IMQ to 2MQ and 1000MQ to 2000M 2 lt 10 General Specifications Power 6 1 5V AA Batteries Operating Temperature 0 to 40 C 32 to 104 F at a relative humidity of lt 80 Size 4 1 H x 7 0 W x 2 1 D Weight 13 oz Supplied Accessories
63. olution 1 Accuracy 0 5 50 Overload Voltage 600V DC or AC peak Continuity Test Voltage 1 7V Threshold 100 digits Overload Voltage 600V DC or AC peak SPECIFICATIONS Frequency Ranges 100Hz 1KHz 10KHz 100KHz 1MHz 10MHz Best Resolution 0 01Hz Accuracy 0 05 5d Overload Voltage 600V DC or AC peak RPM Range 240 to 60 000 RPM Resolution 1 RPM Accuracy 0 05 5d Pulse Width Range 215 to 500Ms pulse width gt 2 5 Duty Cycle Range 25 to 75 LCD Display Size 2 5 x 2 5 General Specifications Power 4 8V NiMh battery pack 120V to 9V 1A DC adapter Battery Life 4 hours without backlight 3 hours with backlight on Display 132 x 128 Pixel super twist LCD Size 7 5 H x 3 5 W 1 57 D Weight 1 5 lbs Standard Accessories Manual Carrying case Test leads Holster RS 232 cable Software AC DC charger Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Power Supplies with Analog Displays Continuously variable Voltage and Current output Short circuit and overload protected Separate meters for monitoring voltage and current Excellent regulation and ripple specs Constant Voltage and Constant current indicators Ideal for the service bench Cost effective 4 Protek DN SPECIFICATIONS 303 Output Voltage Range 0 to 30V Ou
64. or AC peak 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Auto ranging Vertical and Horizontal scales Built in auto manual ranging True RMS 4000 count DMM DC to 1MHz bandwidths Hand held and battery operated Designed to UL3111 CSA C22 2 No 1010 standards RS 232 Port and supplied software User friendly front panel Frequency Ranges 100Hz 1KHz 10KHz 100KHz 1MHz 10MHz Best Resolution 0 01Hz Accuracy 0 05 5d Overload Voltage 600V DC or AC peak RPM Range 240 to 60 000 RPM Resolution 1 RPM Accuracy 0 05 50 Pulse Width Range 215 to 500Ms pulse width gt 2 5 Duty Cycle Range 25 to 75 LCD Display Size 2 5 x 2 5 General Specifications Power 4 8V NiMh battery pack 120V to 9V 1A DC adapter Battery Life 4 hours without backlight 3 hours with backlight on Display 132 x 128 Pixel super twist LCD Size 7 5 H x 3 5 W 1 57 D Weight 1 5 lbs Standard Accessories Manual Carrying case Test leads Holster RS 232 cable Software AC DC charger 2405 Vertical Oscilloscope Bandwidth 5MHz Resolution 8 bits Number of Channels 2 Coupling AC and DC Input Impedance 1M Accuracy 3 Max Input Volts 600V DC or AC RMS Vertical Sensitivity 50mV Div to 500V Div in a 1 2 5 sequences Horizontal Oscilloscope Sample Rate 50MS s single channel 2
65. rker Sequency Level Sweep Mode Reception Mode SPECTRUM DISPLAY This Mode scans and displays 160 channels Squelch level may be set above or below carrier level in order to pause scan and detect the signal Detection modes are AM NFM WFM and SSB Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 37 Website www protektest com Email sales protektest com Hand Held 2 9GHz RF Signal Strength Analyzer Hand Held and battery operated 100KHz to 2200MHz measurement range 125 Ch sec scan rate Built in 2 9GHz frequency counter High sensitivity 117 dBm max Detects Wide band and Narrow band FM AM and Single Sideband Signals Phase lock loop for precise frequency tuning RS 232 interface includes software and cable Up to 160 channels may be scanned and displayed Audio output with built in speaker Detachable antenna included Back lit display All functions are menu selected Instrument setups amp display data may be stored in memory Hard copy printer output of spectrum and bar graph displays Ideal for IEEE 802 11 applications Cellular Telephones RF paging systems Indoor repeaters Surveillance applications SPECIFICATIONS Frequency Frequency Range 100KHz to 2900M Hz Frequency Step 5KHz to 9995KHz in multiples of 5KHz or 6 25KHz Ref Oscillator Accuracy 3 PPM Frequency Marker Accuracy 25 PPM Frequency Measurements Narrow Ban
66. rrier Frequency 9 digit LED Modulation 3 digit LED Output Level 4 digit LED Memory Location 2 digit LED General Specifications Input Power 110 220V Frequency 50 60 Size 4 7 H x 17 W x 17 7 D Weight 26 5 05 Standard Accessories Operation manual Line cord and Type N cable Optional Accessories GBIB interface t e IA 17 18 19 20 14 15 16 1 Power On off 2 Increases 4 or decreases the mod or Mod Frequency by a preset value In the second function selects 3 5KHz or 22 5 KHz FM deviation 3 Displays Modulation in AM and Frequency Deviation in FM Selects 400Hz or 1KHz modulation frequencies In the 2nd function selects 75KHz deviation or 30 AM modulation 5 Increments or decrements the memory address 6 Displays the Memory Address 7 Displays the RF Output Frequency 8 Function cursor keys The outer 2 keys selected the display to be changed the inner 2 keys select the digit in the selected display to be changed 9 The Delta Frequency is used to generate a new output frequency by adding or subtracting the delta value to the current frequency 10 keys determine if the Delta frequency is added or subtracted to the current frequency 11 Turns the output on or off In the second function selects the dB units 12 Displays the RF Output Level Synthesized AM FM Signal Generator 21 22 13 These keys are used to store preset R
67. t Coupling AC only Trigger Level Auto Measurement Range 0 01 to 99 99 Frequency Range 0 to 100KHz RPM Input CH A Measurement Range 0 to 600 000 RPM Minimum Pulse Width 250ns Resolution 0 1 RPM The supplied software is a Windows based program which runs under Windows 95 98 ME XP 2000 It allows the user to set the Instrument Parameters from the PC via the RS 232 interface and provides time stamped data logging for all functions General Specifications Display 128 x 64 pixel super twist LCD Line Voltage AC input Volts 85 to 270V AC 10 Line Frequency 48Hz to 66Hz Toia Input Characteristics Power Consumption 15W Channel A amp B i ting T 0 to 40 C 32 to 104 F Input CH A Frequency Range 0 to 120MHz Temperaturer Frequency Range DC to 10MHz Count Capacity 0 to 99 999 999 counts Resolution 1 count Accuracy 1 count Sensitivity 25mV Input Impedance 1MQ 35uF capacitance Attenuator X1 X10 Maximum Input Volts 250V DC or AC peak Size 3 3 H x 11 6 W x 11 0 D Weight 4 4 Ibs Supplied Accessories Manual Line cord BNC cable Software RS 232 cable Optional Accessories GPIB installed Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com 3 0GHz Universal Counter High accuracy frequency measurements to 3 0GHz Measures Frequency P
68. t Characteristics Frequency Range 10Hz to 1MHz in 5 ranges Frequency Accuracy 10Hz to 1MHz 5 100Hz to 100KHz 3 Amplitude gt 20V P P open circuit gt 10V into 600 2 Output Impedance 6000 Output Attenuation 0dB 20dB 40dB steps and fine adjustment attenuator control Sine Wave Characteristics Distortion 0 0596 from 500Hz to 50KHz 0 596 from 50Hz to 500KHz Square Wave Output Frequency Range 10Hz to 100KHz Output Voltage gt 15V P P Rise Time 500ns External Sync Input Input Impedance Approx 10K 2 Max Input Voltage 10V RMS General Specifications Power Requirements 115 230V 10 Frequency 48Hz to 66Hz Power Consumption 3VA Size 6 0 H x 10 0 W x 5 0 D Weight 5 5 lbs Supplied Accessories Manual Line cord Test leads Special Purpose Instrument Digital Insulation Testers DI2001 01010 DI2001 Cat Insulation Tester m Measures insulation resistance to 2GQ 250V 500V and 1000V test voltages m Meets IEC 1010 1 Category IIl 600V safety standards m Data and Max hold 3 1 2 digit 2000 count LCD Continuity buzzer DI4000 Insulation Tester Measures insulation resistance to 2GQ Measures AC volts Data hold and backlight 3 1 2 digits 3200 count LCD Designed to IEC 1557 2 standards Rugged case and lightweight 125V 250V and 1000V test voltages DI2001 DI2001 DC Voltage Range 0 to 1000V Resolution 1V Accuracy 0 5 Rdg 1d AC V
69. tage 1000V DC or AC peak Input Impedance 10M DC pA Ranges 500g A 5000 Best Resolution 10 0nA Accuracy 0 15 1d Overload Protection 0 5A 250V fuse DC mA Ranges 50mA 500mA Best Resolution 1 01 A Accuracy 0 15 10d Overload Protection 0 5A 250V fuse 50 000 Count Multimeter 50 000 count and 50 segment bar graph backlit display Basic DC accuracy is 0 03 RS232 interface with software and cable dBm measurement with 40 to 12000 reference resistances AC and AC DC TRUE RMS measurement Measures frequency Duty cycle and Capacitance Cat Ill 1000V Max Min and Relative measurements Auto power off and backlit display 6500 DCA Ranges 5A 10A Best Resolution 100 Accuracy 0 5 10d Overload Protection 10A 250V fuse AC pA Ranges 500p A 50001 A Best Resolution 10 0nA Accuracy 0 75 10d 40Hz to 1KHz Overload Protection 0 5A 250V fuse AC mA Ranges 50mA 500mA Best Resolution 1 01 A Accuracy 0 75 204 40Hz to 1KHz Overload Protection 0 5A 250V fuse ACA Ranges 5A 10A Best Resolution 100 Accuracy 40Hz to 1KHz 5A 0 75 20d 40Hz to 1KHz 10A 0 75 20d Overload Protection 10A 250V fuse Resistance Ranges 500 2 5KQ 50KQ 500K 2 5M 2 50M D Best Resolution 10 0mO Accuracy 0 1 50 Max Input Voltage 250V Continuity Buzzer Buzzer Will Sound lt 60 resistance Capacitance Ranges 50nF 500nF 5uF 50
70. th 100 1 frequency control Less than 0 5 sine wave distortion Variable symmetry Sweep time from 20ms to 2 seconds TTL sync output DEDOTCPEPEE SWEEP RATE PULL SWEEP WIDTH svw PULL SPECIFICATIONS Output Characteristics Frequency Counter Frequency Range 0 02Hz to 2MHz Modes Internal and external Ranges 7 Measuring Range 0 005Khz to 2000KHz Output level No of digits 4 High 10Volts into 50 2 Low P P into 50Q Waveforms Sine Square Ramp Pulse Impedance 50Q DC offset 5 0V in to 50Q Sine Wave Distortion 0 596 from 5Hz to 20KHz Triangle Linearity gt 99 to 100KHz Square wave Rise Fall Time 100ns into 50 Pulse Duty Cycles 20 80 to 80 20 may be obtained Sweep Types Linear Sweep time 2ms to 20s Sweep width variable to 100 1 Accuracy 0 01 1count Sensitivity 100mV rms Input Impedance 1MQ 25pF Max input V 150V DC and AC rms General Specifications Line Voltage 120 220V 50 60Hz Dimensions 3 1 H x 9 0 W x 10 4 D Weight 4 4 lbs Operating Temperature 0 to 452C 32 to 113 Accessories Manual Line cord BNC cable Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com 4 MHz Sweep Function Generator Wide 0 004Hz to AMHz Frequency range CW Triggered and Gated modes Sweep output and VCG input 1000 1 lin
71. tput Current Ranges Range 1 0 to 3A Range 2 0 to 600mA Load Regulation Constant Voltage 0 01 3mV Constant Current 0 2 3mA Line Regulation Constant Voltage 0 01 3mV Constant Current 0 2 3mA Ripple Constant Voltage 2mV RMS Constant Current 2mA RMS Readout Analog for both voltage and current Meter Accuracy 5 of full scale for both voltage and current General Specifications AC Input Volts 120 220V selectable Power Consumption 190VA Operating Temperature 0 to 40 C 32 to 104 F Size 5 0 H x 6 3 W x 13 0 D Weight 14 lbs Supplied Accessories Manual Line cord Test leads Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com 310 310 Output Voltage Range 0 to 30V Output Current Ranges Range 1 0 to 10A Range 2 0 to 2A Load Regulation Constant Voltage 0 04 2mV Constant Current 0 4 2mA Line Regulation Constant Voltage 0 05 3mV Constant Current 0 4 5mA Ripple Constant Voltage mV RMS Constant Current 1mA RMS Readout Analog for both voltage and current Meter Accuracy 5 of full scale for both voltage and current General Specifications AC Input Volts 120 220V selectable Power Consumption 520VA Operating Temperature 0 to 40 C 32 to 104 F Size 5 0 H x 6 3 W x 13 0 D Weight 26 Ibs Supplied Accessories Manual Line cord Test
72. uF 500uUF 5000p F Best Resolution 10pF Accuracy 1 0 50 Maximum Input Volts 250V 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 SPECIFICATIONS Diode Test Range 2 5V Resolution 0 1mV Accuracy 1 0 5d Test Current Approx 0 7mA Logic Frequency Sensitivity 2V to 5V Square wave Accuracy 0 006 4d Frequency Range 5Hz to 2MHz Frequency Ranges 5Hz to 200KHz Best Resolution 0 001Hz Accuracy 0 006 4d Input Sensitivities Range Sensitivity 500mV 0 1V 5V 0 5V 50V 4V 500V 40V 1000V 400V 50004 A 10001 500mA 100mA Duty Cycle Range 0 to 90 Resolution 0 01 Accuracy 10 General Specifications Operating Temperature 0 to 302C 32 to 86 80 Relative Humidity 31 to 512C 87 to 124 F 50 Relative Humidity Power 6 AAA Batteries Size 7 9 H x 3 94 W x 1 57 D Weight 1 23 lbs Accessories Manual test leads RS 232 cable and software CD Protek Test amp Measurement Website www protektest com Email sales protektest com 304 305 A480B 304 3 1 2 Digit AC DC Mini Clamp On Meter Measures AC DC current to 1000A Manual ranging Measures Volts Amps and Ohms 1 37 Jaw opening for cramped wiring locations Overload protection with indicator Data hold Fused input Meets IEC 1010 Category 600V safety standards SPECIFICATIONS 304 Volts DC Ranges 200V Best Resolution 0
73. x Trigger gate minimum pulse width 50ns Sweep Type Linear and Log Sweep Time 30ms to 60 seconds continuously variable Sweep width 1 1 000 linear 1 10 000 log continuously variable S weep start and stop frequencies may be set with the Freq dial and the Freq Stop control Outputs Sync TTL level GCV output proportional to the selected frequency 0 to 5V Sweep 4V Impedance 6000 VCG Input Input Voltage 0 to 4V P P will cause a 1 1 000 frequency change linear and 1 10 000 Log Input Impedance 2KQ General Specifications Operating Temperature 0 to 50 32 to 120 F Dimensions 3 5 H x 11 4 W x 10 6 D Weight 5 05 AC line Voltage 120 220V 50 60Hz Accessories Manual Line cord BNC cable B8110 1OMHz Sweep Function Generator 1OMHz Generators B8110 B1990 B1990 10MHz Pulse Generator 1Hz to 1OMHz Frequency Range Variable Pulse width and Delay Manual and External triggering Output amplitude to 5V p p into 500 May be crystal controlled m Wide 0 01Hz to 10MHz frequency range E Log Lin sweep m Burst gate and triggered modes Output may be FM modulated using input m Low distortion Sine wave E m Sweep start and Stop capability o 5 oe TE ae RATE S 34 107 5 p mmm T o e B8110 Frequency Characteristics Frequency Range 0 01Hz to 10MHz Output Chara
74. ype 2 standards m 3 1 2 digit LCD display m A amp C frequency weighting m O IdB resolution E Maximum hold function Internal calibration check m Fastand slow response Analog output jack SPECIFICATIONS SL100 Measurement Ranges Frequency 31 5Hz to 8KHz Decibel A Lo Weighting 35 to 100dB A Hi Weighting 65 to 130dB C Lo Weighting 35 to 100dB C Hi Weighting 65 to 130dB Best Resolution 0 1dB Accuracy 20 Dynamic Range 65dB Input Condenser Microphone Time Weighting Slow or Fast Maximum Hold Decay lt 1dB 3min Analog Output AC Conditioned 0 7V RMS corresponding to each range step Output Impedance 6009 DC Conditioned 10mV dB Output Impedance 1000 General Specifications Operating Temperature 0 to 50 32 to 122 F at relative humidity of less than 8096 Power 9V battery for 100 hours life with alkaline battery Size 9 5 H x 2 7 W x 1 0 D Weight 7 6 0z Supplied Accessories Manual battery Adjustment screwdriver Carrying case Protek Test amp Measurement 45 Smith Street Englewood NJ 07631 Tel 201 818 7711 Fax 201 760 9888 Website www protektest com Email sales protektest com Special Purpose Instruments Audio Products B850 Audio Generator Wide 10Hz to 1MHz Frequency range Low distortion Sine wave and Square wave output Lightweight Rugged construction Frequency setting via large frequency dial Ideal for classroom or audio bench B850 Outpu