1. Doc WI JS 538 006 oe 4 E a H i ZC 208T High Accuracy Smart MagnetoMeter Guide for Use and Maintenance Overview ZC 208T is minitype magnetic method prospecting instrument which is designed by ZC Tech The measured data by the magnetic sensor can be indicated user data can be stored and sent to host PC by USB interface Build in GPS can be orientation accurately Remarkable Features gt VV V V gt Portability simple operation smart build in GPS Solid hard to be damaged simple maintenance High resolution portable wide range stable performance Strong capability of anti jamming Internal temperature compensation calibration Communication and analysis with PC Specification ZC 208T smart magnetometer is a solid Objects of measurements Measured directly magnetite hematite magnetite with Va Ti or Ag Cu Measured indirectly metal mine with Fe Co Ni Probe for magnetic objects Direction of measurement geomagnetic vertical component or geomagnetic horizontal component Range 100000nT 100000nT Resolution InT e Accuracy lt 0 5 full range Measuring method directly test in all range e Data storage data of 5000 testing points Data collection frequency 6 times s Power of whole instrument 180mA 200mA Powersupply powerful Li battery which can be charged up 2000mAH e Work temperature 10 C 50 C built in temperature compensation e D
2. pres record look up button OM save current data and save state will be indicated by action info column Note In R M State make sure probe is horizontal ir the tray and in same direction of north pole of north finder same condition as set base line or there is no comparability between measured value and baseline Press record look up button to saved current data info when exit continuous measurement At this time baseline page up button is with function o page up R M page down button is with function of page down A M bottom button is with function displaying the last data 2 Mode 2 A M mode G adjust levelling Fix up the tripod A bubble is installed on the tripod Adjust the three foots of tripod for rough adjustment then adjust the three bolts to make the bubble float in the circle After adjusting flatly put the probe onto the flat roof of tripod then connect the probe with display Shanghai Zhichuan Electronic Tech Co Ltd 3 Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com ZC hh 2 www ze sensor com Doc WI JS 538 006 Ver A 0 2 warm up press the Power button for 3s make the power on and warm up for ten to fifteen minutes to make system be in the best state 3 Enter into the measurement interface Under rough measurement mode when exit every working condition and press the accurate measurement button bottom button button 22 you
3. Software Interface and Function Instruction AnH FA o M l 4 n F a i a a T a ii va Ba sare n MH a H is 7 rer Bin 2 ore 629 2 3713 a GRR RRR ERE Ee Bee T Mio es ALENEN Lee THERRET BARREA Please choose com port otherwise no data Click the Data Input data is imported from controller to the software Data read state Choose the format then save data txt is used to draw 2D drawing dat is used to draw 3D drawing G I GO INS Choose Base Line Value Choose all all data are saved Choose one of base line value data saved only is measured in this base line value anc data in other base line value shall not be saved and displayed 6 Input measure number of row Only in dat format allowed manual input The number of row can not be negative number 7 Exit the software Header followed by number of measure site exceptional value compared with base line value GPS site the measure site s GSP latitude anc Shanghai Zhichuan Electronic Tech Co Ltd 4 Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com WWW zc sensor com Doc WI JS 538 006 Ver A 0 longitude coordinates date date of measure site base line value remarks measure way rough measure or accurate measure 9 Delete source data in controller Calculate the area value of measure s
4. can ente into the accurate measurement modle press the base line page up button button 19 then press the record look up button button 20 in 0 90 180 270 degree four direction one by one in this way can get the base line data after this operatation all the date uner the accurate measurement modle is the D valuc between measurement data and base line data when the new base line date set down you can operate accurate measurement press the start stop button buttot 18 in 0 90 180 270 degree in four direction one by one The systerm can calculate save and show the accurate measurement data Automatically wher exit every working condition and press the record look up button button 20 you can check the the measure data under current modle the other button have the same fuction as the rough measure modle turn off When finishing the measurement please press the Power button button 17 4 seconds the power supply will cut down The systerm will automatically record the data of every point On the same base after measuring a number of points send the data to host PC we can lool over all of the data and transfer the data format suit to professional drawing tool 1 Data viewer software G Firstly install the USB driver prospecting magnetometer USB driver PL2303 operate as the prompt step by step 2 Secondly install the prospecting magnetometer data viewer software click the setup operate as the prompt step by step untill it finish 2
5. el 021 64908093 64908096 E mail zcsales zc sensor com 20 mSS www zc sensor com Doc WI JS 538 006 Ver A 0 After sale service Thanks for purchasing and using out ZC 208T smart magnetometer In order to make you satisfy with our services more please read the clauses carefully anc keep properly after buying Clauses e If the product you purchased is damaged owing to non artificial factors in 12 months after the day you purchased we will mend it without labor cost bu should collect the cost of materials e For the upgrade products the past time should be included in the time limit of guaranteeing gt Before guaranteeing to mend we will telephone the customers to find the problems and affirm the reasons of fault gt Such situations are out of the range of guaranteeing 1 Open up the probe without authorization 2 Don t follow the operation rules causing abnormity 3 Out of the time limit of guaranteeing 4 Damaged by artificial factors gt The material and labor cost of maintenance will be charged appropriately for such situations out of the range of guaranteeing gt The power of interpretation of this clause belongs to Shanghai Zhi chuan Information tech co Ltd If you have any questions please contact us Shanghai Zhi chuan Information Tech Co Ltd Address 2F Dongli Building SJTU 800 Dongchuan Rd Minghang Shanghai China Tel 021 64908093 64908096 Fax 021 64906992 Zip Code 200240 http www zc sensor com e mail sa
6. fo can be indicated in this column 11 rough measurement button it is used to choose R M mode 12 accurate measurement button it is used to choose A M mode 13 Record start button it is used to indicate data state 14 coordinate info longitude and latitude info 15 time info GPS time 8h differ with Beijing time 16 p n info can be customized 17 Power button short press is for closing background light long press for 4S is for power off long press for 3S is for starting up 18 start stop button can bs refer to mode definition 19 Base line page up button refer to mode definition 20 record look up button refer to mode definition 21 R M page down button refer to mode definition 22 A M bottom button refer to mode definition 23 probe connector is used to power probe and upload probe data 24 battery charging connector battery charging 25 USB connector 2 Mode definition If power indicator light os is not on when starting on power supply of probe is fault If probe indicator light i is not on probe data is fault If system indicato light pa is shining it is low battery power and need to be charging When probe is connected with host PC USB indicator light will be on if no any action ir 5mins after starting on background light will be off in Smins and power off in 10mins The whole system is including 2 modes they are R M mode E and A M mode ET as follow 1 Mode 1 R M mode 1 Co
7. isplay mode Differential display large LCD screen with background lights Probe size 75mm X 90mm Size of strut for rough measurement 18mm X 1000mm Power cable 1 5m Shanghai Zhichuan Electronic Tech Co Ltd l Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com Www zC Sensor com Ver A 0 ES aS www zc sensor com Doc WI JS 538 006 Panel function instructions A state indicator light area B display area C push button D probe connector E battery charging F USB interface Operating instructions SWART MAGNETOMETER 1 Function definition Shanghai Zhichuan Electronic Tech Co Ltd Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com Nb www ze sensor com Doc WI JS 538 006 Ver A 0 1 power supply indicator light of probe 2 USB indicator light 3 work state indicator light of probe 4 work state indicator light of system 5 company info can be customized 6 base line value it is reference value to certain area 7 new base line button it is used to build new base line value 8 data it is D value between actual magnetic value and base line value 9 Horizontal magnetic field intensity the bar dynamically display general horizontal magnetic field base line value and exceptional info 10 action infc column action in
8. ite 41 Delate all data in the above form 3 Data read instruction 12 Choose com port 13 Chick Data input data begin to be input After inputting there shall be a tip of delete data in controller Customers can choose 1 Choose the data format when saving 15 Click Save data When choose dat format please input the measure number of row 16 Measuring as multiple different base line follow as 3 2 5 4 Attention 4 Click Exit after operating Draw 3D drawing it shall regard GPS coordinates the latitude maximum point and longitude minimum point as the starting point automatically Attentions when draw 3D drawing x GPS value can not be 0 or none When GPS is 0 then calculate as previous number and input into the form manually Atleast measure three line and more than five site in each line It s better to keep the distance gt 15m between two measure site when the GPS signal is bad It s better to keep the distance gt 10m wher the signal is good 20 When using the device it s better to measure as straight line 5 Draw 2D profile drawing 21 Save txt format then draw 2D drawing Use GRAPHER to draw Follow steps 22 Open the software and choose Graph gt Line or Symbol as Picturel 6 Draw a 3D test chart G Save data in format txt for drawing 3D Use Sufer 10 32 bit make drawing Steps as below 2 Open Surfer software choose Grid gt Data option picture 5 select the d
9. les zc sensor com Final interpretation of the above clause is owned by Shanghai Zhichuan Electronics Tech Co Ltd This User manual if for reference only Shanghai Zhichuan Electronic Tech Co have the right of making modification without notice Shanghai Zhichuan Electronic Tech Co Ltd 9 Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com Doc WI JS 538 006 Guarantee card Product Name Model ZC 208T Date of purchasing Time Limit of Guaranteeing Company Purchasing Product SN Record of mending Information of customer holding this Guarantee Card Note This card is the basis for users enjoying maintaining and upgrades service Report Time Reasons of fault Reporter Results of mending Shanghai Zhichuan Electronic Tech Co Ltd Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China 021 64908093 64908096 E mail zcsales zc sensor com Tel Www zC Ssensor com Ver A 0 Shanghai Zhi chuan Information Tech Co Ltd Address 2F Dongli Building SJTU 800 Dongchuan Rd Minghang Shanghai China 021 64908093 64908096 T 021 64906992 F Hb 4 Zip Code 200240 http www zc sensor com E mail webmaster zc sensor com x ifs Ce aS WWww ze sensor com Doc WI JS 538 006 Ver A 0 Box list Model ZC 208T smart magnetometer Oooo eon fo e m pho o e dS Porce ooo S Tipoa Equipment for Two s
10. mmon magne is about millions of nT it s far away the range of the probe The accuracy will get weaken and even worse the probe may be damaged 3 The number of charging up is limited for the lithium battery of the probe If you find that the lithium battery can be charged up very fast and will exhaust in lt short time it means the life of the lithium battery is expired please contact the manufacturer and change the lithium battery 4 There are electronics circuits inside the probe so they should be waterproof avoiding damage owing to short circuit Size SRGRT MiSWETGETEE G 208T PO oer a Shanghai Zhichuan Electronic Tech Co Ltd 7 Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com 20 aS www ze sensor com Doc WI JS 538 006 Ver A 0 Order info P N ZC 208T Stand fittings ZC 208T Probe l Indicator l 1 Indicator l 2 Lithium Battery l 3 tripod 1 USB Cable l Power amp data cable l Equipment for rough measurement 1 1 support rod l 2 tray l toolbox l charger l leather bag i technical documents 1 ZC 208T magnetometer specification file l 2 ZC 208T magnetometer certificate of inspection l 3 software and CD ROM drive l Optional accessories Lithium Battery Shanghai Zhichuan Electronic Tech Co Ltd 8 Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China T
11. nnect Fix the probe on the pole connect the probe and indicator by power cable note when fix the probe on tray it s better to align the indicate line of tray anc probe In this condition when exceptional condition is detected by R M and confirmed by F M we can make sure the continue R M is toward the same direction After fixing please reinforce by set screws 2 Preheat finding direction and levelling Press button for 3s then preheat for 10 15mins to let instrument come into the best working state Rotate bracing pole to let indicate line of tray aim tc pointer of compass north pointer or south pointer are all right Adjust the bubble to make sure tray is horizontal At the same time probe will be horizontal When finding direction the tray can be aim to some direction and keep this direction in subsequent measuring 3 Come into measuring interface This mode is defaulted when power on In this mode press base line page up button new base line button will become gray and data column wil continuously display measured data When these data are stable press record look up button the data can be saved as current base line value then in thi mode all the data displayed are D value of general value and base line value After exit of Setting R M base line press start stop button to come int continuous measurement state When record save button MRA display record and change grey data is ready and can be saved After data are stable
12. ocument then it will show as picture 6 Shanghai Zhichuan Electronic Tech Co Ltd 5 Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com Doc WI JS 538 006 Ver A 0 qE Min Abii Fee Pem miman inia jaa Mni Momie nin m Sada a aenn i E T Tie at 2 Fe FO e a er ee qr z Cisa F AAA CIES i 2S L 7 ee Big Ace Bis ar Adie A Cee Wed 3 Click ok as following show the picture number 7 and click yes Close the window as showing in picture 8 When dialog box appear clicl no oas E N E E E u O BES 5 Generate contour map picture 11 3D picture picture 12 Shanghai Zhichuan Electronic Tech Co Ltd 6 Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com Www zc sensor com Doc WI JS 538 006 Ver A 0 Care and maintenance 1 ZC 206T smart magnetometer is a precision instrument please put it in the clean dry environment without such corrosive gas as sour alkali salt etc 2 The design and make of ZC 206T is extremely professional and technical therefore please don t examine and repair by yourself Because electrostatic may d damage to lots of the electronic devices 2 Special Care Please don t put the probe with strong magnet for a long time otherwise the performance will get weaken Because the intensity of co
13. taff cwe fd Tew fi Users Manual l Two users guide Two CD Affirm Please sign and return this card in two days after receiving our magnetometer otherwise we will consider that we have provided eligible products for you and meanwhile you have no dissidenc Shanghai Zhichuan Electronic Tech Co Ltd 11 Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com ZC Su eS www z e sensor com Doc WI JS 538 006 Ver A 0 Shanghai Zhichuan Electronic Tech Co Ltd 12 Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com el ZC U www zZc sensor com Doc WI JS 538 006 Ver A 0 Shanghai Zhichuan Electronic Tech Co Ltd 13 Add 3F compositive Building No 1128 denghui Rd Min hang Shanghai China Tel 021 64908093 64908096 E mail zcsales zc sensor com